Home
PCL-1512_24M user manual
Contents
1. BAT DC Loading DC Loading Solar Panel Lead acid Battery Figure 1 VI Wiring Dry Contact Control Wiring 200W MPPT Charger 14AWG PV Blue gt PV Brown 18AWG Bat Sensor Red Bat Sensor Black 10AWG BAT Red BAT Black 14AWG Dry contact White amp Orange Bat Dry sensor BAT Contact AC Loading Switch Control Line Inverter BAT Solar Panel Lead acid Battery Figure 2 11 VII Cautions E Recommended Battery Specification 12V 200Ah above or 24V 100Ah above m Be sure the voltage of batteries and PV panels is within the range given in the specifications m The charge controller should be installed in a cool dry and well ventilated area without any flammable items E The length of battery wires should be shorter than 5 meters m Before connect PV panels to the controller make sure a battery has been installed properly and the controller can be started normally m Please unwire the input terminal and then batteries before removing the controller which could be damaged permanently if those steps are followed correctly m Ifthe PV panel is not wired correctly to the controller e g the positive negative poles are wired reversely a short circuit could happen or the fuse could burn out VIII Operation Instructions m Discharge Mode Options 16 segments available Please refer to the Load Switch section in this manual Day Night Mode Detectio
2. LayQut src 6 LED Status Indicators 6 OGG Willis id 7 Charge Current SWICA secs costesesisectsds ctveurowcesbendecausancissadesdasnaedeamseueseenteaes 8 O satessscascuce cuadcesvctvctansanteoedets vines dials Acnsceticieastesscsconeacs accessbecuetesnantconenes 9 CAUTIONS Sesto hese ax ccs eect he es a T 12 Operation InStUCUON Smart 13 PU OLS A AA S 14 Maintenance usina dla 14 Specification PV Charge Controller Specification Converter Efficiency MPPT gt 85 gt 90 Efficiency 10 41Amp charging per 10min charging per 10min Load Current DC 16Amax Dry Contact Can be an inverter starter Power Consumption lt 1W sleep Mode O oO Gross Weight 1 8kg ll Basic Product Layout LED Light Charging Light Load switch Charging Current switch IN LED Status Indicator The LED lights indicate MPPT charging discharging and battery status Table 1 shows the relation between the LED lights and battery status LED Status Indicator PCL 1512M PCL 1524M SOLAR RED LED Blinking Blinks once per second when charging BATTERY RED LED Blinking Stop discharge lt 11 5V Stop discharge lt 23V BATTERY RED LED ON Low 12V 12 8V Blinks once per second when load is normal Table 1 IV Load Switch Load switch manages discharging time based on requirement Our product provides 16 segments load management please see below Discharge Mode 0 OFF 1 ON Load Output 0000 TEST mode for 5min 0001 2 ho
3. MPB ar Buying Solar should be this easy USER MANUAL PCL 1512M PCL 1524M 200W 250W MPPT charge controller with load control V 1 0 WWW MPPSOLAR COM Import Safety Instructions Improper handling may cause a very WARNING hazardous situation resulting in personal injury or loss of life Improper handling may cause A CAUTION personal moderate minor injury or equipment damage General Safety Instructions Please follow all the instruction and warning markings in this manual and on the controller Do not remove or bypass grounding pin Make sure the surface of the controller is connected to earth Please check the appearance of controller before installation Contact your sales agent if there is any obvious damage Please keep the controller from moisture Do not leave any heavy item on the top of the controller To reduce the chance of short circuits use insulated tolls when installing or working with the controller This controller should ONLY be installed and maintained by qualified professionals Please keep this manual for your future reference Check the Controller and Parts The package should include a charge controller and user manual Please contact your local dealer if there is any damage on the appearance of the charge controller or missing page in the manual Charge Controller 1 User Manual 1 Fixing Plate 2 Content VI VII VII SDECINGALION nerds 5 Basic Product
4. ition to ensure the whole system can function well m Please contact your local service center if the controller does not function normally Do not try to repair it by yourself or remove the warranty labels The voltage accuracy will be within 5 range 14
5. n the controller will switch to day night mode based on the input voltage from PV panels Therefore the PV panels needs to be installed properly before this function starts to work Day Night Mode Switch It takes the controller 10 20 minutes to determine that it s daytime or nighttime Please see the table below Day Mode The controller will discharge battery only during daytime E Night Mode The controller will discharge battery only during nighttime Detection Time Normal LOAD Discharge Mode first time after the Detection l Discharge controller is started Time Testing Mode Immediately Immediately IX Protection Surge Protection Advanced MPPT charger protection from noise and surge Battery Low Voltage Disconnect A low voltage disconnect is used to protect the battery from excessive discharge by automatically turning off a load E Constant Voltage Charge When the battery voltage is between 13 8V and 14 4V or between 27 6V and 28 8V based on model the MPPT function will turns off Then the charger will enter into a floating charge mode when the battery voltage is over 14 4V 28 8V the controller will change to a pulse charge mode 1 minute charging per 10 minutes X Maintenance m The charge controller only requires little maintenance if it is used properly Please periodically clean the controller surface with wet clothing In addition please keep the PV panel and battery in a good cond
6. urs on at night 0010 4 hours on at night 0011 6 hours on at night 0100 8 hours on at night 0101 10 hours on at night 0110 12 hours on at night 0111 Full on 1000 TEST mode for 5min V Charge Current Switch The charging current switch can adjust current based on power The set up modes are defined as the followings Discharge Mode 0 OFF 1 ON Charge Current VI Wiring Wiring Instructions m PV PV Line connect the output of solar panel to the PV PV lines of the controller 14AWG Blue PV Brown PV mE BAT Line connect to the positive polarity of a battery 10AWG RED m BAT Sensor Line connect to the positive polarity of a battery to detect its voltage 18AWG RED m BAT Line connect to the negative polarity of a battery LOAWG BLACK m BAT Sensor Line connect to the negative polarity of a battery to detect its voltage 18AWG BLACK m Discharge Control Signal Line dry contact can work as an inverter Starter 14AWG 2 White Orange E Ground Line this line is for grounding to avoid damage from spikes such as lightning strike 14AWG Yellow and Green Stripe Please refer the following wiring charts VI Wiring DC Load Wiring 200W MPPT Charger 14AWG PV Blue gt PV Brown 18AWG Bat Sensor Red Bat Sensor Black 10AWG BAT Red gt BAT Black 14AWG DC Loading White amp Orange PV Bat input sensor