Home
        NI PXI-1031/PXI-1031DC User Manual
         Contents
1.                                                                                                              Pin Z A B    D E F  22   GND GA4 GA3 GA2               GND  21 GND PXI_LBRO GND                        LBR2 PXI LBR3 GND  20   GND PXI LBRA PXI LBR5 PXI STARO GND        STARI GND  19   GND PXI STAR2 GND PXI STAR3 PXI 5      4 PXI STARS GND  18   GND PXI TRIG3                4        TRIG5 GND                6 GND  17   GND        TRIG2 GND RSV PXI_CLK10_IN   PXI_CLK10 GND  16   GND PXI                   TRIGO RSV GND PXI TRIG7 GND  15   GND PXI           15   GND RSV PXI STAR6 PXI LBR6 GND  14   GND AD 35 AD 34 AD 33 GND AD 32 GND  13   GND AD 38 GND V I O  AD 37 AD 36 GND  12   GND AD 42 AD 41 AD 40 GND AD 39 GND  11 GND AD 45 GND V I O  AD 44 AD 43 GND  10   GND AD 49 AD 48 AD 47 GND AD 46 GND  9 GND AD 52 GND V O  AD 51 AD 50 GND  8 GND AD 56 AD 55 AD 54 GND AD 53 GND  7 GND AD 59 GND V I O  AD 58 AD 57 GND  6 GND AD 63 AD 62 AD 61 GND AD 60 GND  5 GND C BE S   GND V I O  C BE 4   PAR64 GND  4 GND                          4   C BE 7   GND C BE 6   GND  3 GND PXI LBR7 GND PXI LBR8 PXI LBR9 PXI LBRI10 GND  2 GND PXI LBR11 PXI LBR12 UNC PXI START7 PXI STARS GND  1 GND        5      9 GND        STARIO   PXI STARII PXI STARI2   GND                          National Instruments Corporation B 5 NI PXI 1031 PXI 1031DC User Manual    Appendix B Pinouts    Table B 5  P1  J1  Connector Pinout for the Generic Peripheral Slot                                                    
2.                                                                        1 Power Switch  Standby  3 Rubber Foot  2 AirFlow Filter Cover 4 Air Flow Filter Cover Screw             Figure 1 4  Bottom View of PXI 1031 PXI 1031DC Chassis    Optional Equipment       Contact National Instruments to order the following options for the  PXI 1031 PXI 1031DC chassis     EMC Filler Panels  Optional EMC filler panel kits are available from National Instruments   Rack Mount Kits  A rack mount kit option is available for mounting the PXI 1031 or  PXI 1031DC chassis into a 19 in  instrument cabinet   Handle Feet Kit    An optional side handle and rubber feet kit is available from National  Instruments to provide a handle for portability         National Instruments Corporation 1 5 NI PXI 1031 PXI 1031DC User Manual    Chapter 1 Getting Started    DC Power Cable  PXI 1031DC Only     An optional DC power cable is available from National Instruments to  provide power through the DC input connector on the rear panel of the  chassis     PXI 1031 PXI 1031DC Backplane Overview       Interoperability with CompactPCI    The PXI 1031 PXI 1031DC backplane is interoperable with 5 V and  universal PXI compatible products and standard CompactPCI products   This is an important feature  because some PXI systems may require  components that do not implement PXI specific features  For example   you may want to use a standard CompactPCI network interface card in a  PXI chassis     The signals on the backplane P
3.                                     Pin Z A B    D E F  25 GND 5V REQ64  ENUM  3 3V 5V GND  24 GND AD 1  5V V I O  AD 0          4  GND  23 GND 3 3V AD 4  AD 3  5V AD 2  GND  22 GND AD 7  GND 3 3V AD 6  AD 5  GND  21 GND 3 3V AD 9  AD 8  M66EN C BE 0   GND  20 GND AD 12  GND V I O  AD 11  AD 10  GND  19 GND 3 3V AD 15  AD 14  GND AD 13  GND  18 GND SERR  GND 3 3V PAR C BE 1   GND  17 GND 3 3V SDONE SBO  GND PERR  GND  16 GND DEVSEL  GND V I O  STOP  LOCK  GND  15 GND 3 3V FRAME  IRDY  GND TRDY  GND   12 14 Key Area   11 GND AD 18  AD 17  AD 16  GND C BE 2   GND  10 GND AD 21  GND 3 3V AD 20  AD 19  GND  9 GND C BE 3   IDSEL AD 23  GND AD 22  GND  8 GND AD 26  GND         AD 25  AD 24  GND  7 GND AD 30  AD 29  AD 28  GND AD 27  GND  6 GND REQ  GND 3 3V CLK AD 31  GND  5 GND BRSVPIA5 BRSVPIB5 RST  GND GNT  GND  4 GND               4 GND V I O  INTP INTS GND  3 GND INTA  INTB  INTC  5V INTD  GND  2 GND TCK 5V TMS TDO TDI GND  1 GND 5V  12V TRST   12V 5V GND                                        NI PXI 1031 PXI 1031DC User Manual B 6 ni com    Appendix B Pinouts    Table B 6  P2  J2  Connector Pinout for the Generic Peripheral Slot                                                                                                                         Pin Z A B C D E F  22 GND   GA4 GA3 GA2        GAO GND  21 GND   PXI LBRO GND PXI LBRI PXI LBR2 PXI LBR3 GND  20 GND   PXI LBRA PXI LBR5 PXI LBLO GND PXI LBL1 GND  19 GND   PXI_LBL2 GND PXI_LBL3 PXI_LBL4 PXI LBL5 GND  18 GND   PXI TR
4.                             a trigger line to prevent its configuration by a  user program  Dynamic reservation routing deallocation is performed on  the fly within a user program based upon National Instruments APIs such  as NI DAQmx  Static reservation of trigger lines can be implemented by  the user in MAX through the Triggers tab  Reserved trigger lines will not  be used by PXI modules dynamically configured by programs such as  NI DAQmx  This prevents the instruments from double driving the trigger  lines  possibly damaging devices in the chassis     Complete the following steps to reserve these trigger lines in MAX     1  In the Configuration tree  click the PXI chassis branch you want to  configure     2  Click the Triggers tab at the bottom of the right hand pane   Select which trigger lines you want to statically reserve     4  Click the Apply button     Using System Configuration and Initialization Files       The PXI specification allows many combinations of PXI chassis and  system modules  To assist system integrators  the manufacturers of PXI  chassis and system modules must document the capabilities of their  products  The minimum documentation requirements are contained in     ini files  which consist of ASCII text  System integrators  configuration  utilities  and device drivers can use these   ini files     The capability documentation for the PXI 1031 PXI 1031DC chassis is  contained in the chassis ini file on the software media that comes with  the chassis 
5.            9                1 6  System Controller Slot    2  tertie ete t eot                 1 6  Star Trigger Slot  ucc eR GO A e p RE Re Rien 1 7  Peripheral       reato Ee Pe ent 1 7  Local Bus saei ER n ERR ERR EH UAM      ad ayn esas 1 7  Trigger BUS uie ete PE pod ed re 1 8  System Reference CloCk           vice dede e a i ER ede a ciues 1 8    Chapter 2  Installation and Configuration    Safety Information s s ten o e pete betae p d cec ede een 2 1  Chassis Cooling Considerations                                   nennen eene 2 2  Providing Adequate Clearance 2                     2 2   Seting Fan Speed onis o nt E REESE E        2 3  Installing Filler  Panels  te ER e ete etes en 2 3          MOoUuntinB    eee potere TO sas Ghi eri enr EY Eee RU Een eet D Pee CERES 2 4  Connecting Safety Ground    tee net hee Oe                  2 4  Connecting to PowerSource eet e de e E HORT pee 2 4  Connecting to an AC Power                                 2 5  Connecting to    DC Power Source  PXI 1031DC Only                                  2 5   DE Connector  iae e oett es 2 5        National Instruments Corporation V NI PXI 1031 PXI 1031DC User Manual    Contents    Installing a PXI Controller    tette netten ele entero Spots 2 6  Installing PXI Modules              irae ede gre gerer ttes 2 8  PXI System Configuration with           eee 2 9  Basic PXI System                                                2 10  Trigger Configuration in                   2                   2 1
6.           NI PXI 1031 PXI 1031DC  User Manual    October 2004  371226B 01       NATIONAL    INSTRUMENTS    Worldwide Technical Support and Product Information    ni com    National Instruments Corporate Headquarters  11500 North Mopac Expressway Austin  Texas 78759 3504 USA Tel  512 683 0100    Worldwide Offices    Australia 1800 300 800  Austria 43 0 662 45 79 90 0  Belgium 32 0 2 757 00 20  Brazil 55 11 3262 3599   Canada  Calgary  403 274 9391  Canada  Ottawa  613 233 5949  Canada  Qu  bec  450 510 3055    Canada  Toronto  905 785 0085  Canada  Vancouver  604 685 7530  China 86 21 6555 7838    Czech Republic 420 224 235 774  Denmark 45 45 76 26 00  Finland 385 0 9 725 725 11    France 33 0 1 48 14 24 24  Germany 49 0 89 741 31 30  India 91 80 51190000  Israel 972 0 3 6393737   Italy 39 02 413091  Japan 81 3 5472 2970  Korea 82 02 3451 3400  Malaysia 603 9131 0918    Mexico 01 800 010 0793  Netherlands 31 0 348 433 466  New Zealand 0800 553 322  Norway 47 0 66 90 76 60   Poland 48 22 3390150  Portugal 351 210 311 210  Russia 7 095 783 68 51  Singapore 65 6226 5886   Slovenia 386 3 425 4200  South Africa 27 0 11 805 8197  Spain 34 91 640 0085  Sweden 46 0 8 587 895 00   Switzerland 41 56 200 51 51  Taiwan 886 2 2528 7227  Thailand 662 992 7519    United Kingdom 44 0 1635 523545    For further support information  refer to the Technical Support and Professional Services appendix  To comment  on National Instruments documentation  refer to the National Instruments Web site at 
7.           Pinouts    This appendix describes the P1 and P2 connector pinouts for the  PXI 1031 PXT 1031DC backplane     Table B 1 shows the P1  J1  connector pinout for the System  Controller slot     Table B 2 shows the P2  J2  connector pinout for the System  Controller slot     Table B 3 shows the P1  J1  connector pinout for the star trigger slot   Table B 4 shows the P2  J2  connector pinout for the star trigger slot   Table B 5 shows the P1  J1  connector pinout for the peripheral slots     Table B 6 shows the P2  J2  connector pinout for the peripheral slots          Note        signals are shown in bold        National Instruments Corporation B 1 NI PXI 1031 PXI 1031DC User Manual    Appendix B Pinouts    Table B 1  P1  J1  Connector Pinout for the System Controller Slot                                                                                        Pin Z A B C D E F  25 GND 5V REQ64  ENUM  3 3V 5V GND  24 GND AD 1  5V V I O  AD 0          4  GND  23 GND 3 3V AD 4  AD 3  5V AD 2  GND  22 GND AD 7  GND 3 3V AD 6  AD 5  GND  21 GND 3 3V AD 9  AD 8  M66EN C BE 0   GND  20 GND AD 12  GND V O  AD 11  AD 10  GND  19 GND 3 3V AD 15  AD 14  GND AD 13  GND  18 GND SERR  GND 3 3V PAR C BE 1   GND  17 GND 3 3V SDONE SBO  GND PERR  GND  16 GND DEVSEL  GND         STOP  LOCK  GND  15 GND 3 3V FRAME  IRDY  GND TRDY  GND   12 14 Key Area   11 GND AD 18  AD 17  AD 16  GND C BE 2   GND  10 GND AD 21  GND 3 3V AD 20  AD 19  GND  9 GND C BE 3   IDSEL AD 23  GND AD 22  GND  8 GND 
8.    47 63 Hz         The operating range is guaranteed by design     NI PXI 1031 PXI 1031DC User Manual A 4 ni com    Input current rating                    eene    Over current                                                                                             es    Power disconnect                                        DC Input    Input voltage                                              Input current rating     EAEN G anten tre eg    Power disconnect                                        DC Output    DC current capacity  Imp     Appendix A Specifications    6 3 A fuse in power supply   no user serviceable components  inside chassis     65920 minimum    The AC power cable provides  main power disconnect  The  front panel power switch controls  the internal chassis power supply  that provides DC power to the                              backplane     11 30 VDC  30 A maximum  65  typical    The DC power cable provides  main power disconnect  The  front panel power switch controls  the internal chassis power supply  that provides DC power to the  CompactPCI PXI backplane                             Voltage 0 50  C  43 3 V 12A   5 V 17A   12 V 2A   12 V 0 8 A             National Instruments Corporation A 5    NI PXI 1031 PXI 1031DC User Manual    Appendix A Specifications    5  Notes        output power is derated  5 W   C above 45          The combined loading on  5 VDC and  3 3 VDC must    For DC powered applications at 11 VDC input  the com    not exceed 112 W   
9.   42444222  The AC power cable provides    DC Output    DC current capacity  Imp     main power disconnect  The  front panel power switch controls  the internal chassis power supply  that provides DC power to the  CompactPCT PXI backplane                             Voltage 0 50  C  43 3 V 12     5 V 17A   12 V 2A   12V 0 8          Over current protection                               Overvoltage protection                                Chassis Cooling    Per slot cooling capacity                              Slot airflow direction                                   Module cooling                                                               Exhaust                                    NI PXI 1031 PXI 1031DC User Manual A 2    All outputs protected from short  circuit and overload    114  to 145  above nominal  output voltage    25 W    P1 to P2  bottom of module  to top of module    Forced air circulation  positive  pressurization  through a High  Flow fan with HIGH AUTO  speed selector    Bottom of chassis    Along rear  right side  and top of  chassis    ni com       Power supply cooling    Environmental    Operating location    Maximum altitude    Installation Category    Pollution Degree    Operating Environment    Ambient temperature range    Relative humidity range    Storage Environment    Ambient temperature range    Relative humidity range    Shock and Vibration    Operational shock       National Instruments Corporation A 3    Appendix A Specifications    Forced air
10.   bined loading on  5 VDC      3 3 VDC   12 VDC  and  12 VDC must not exceed 137 W  At 12 3 VDC or higher    input  the combined loading must not exceed 145 6 W     For AC powered applications  the combined loading must not exceed 145 6 W     Overcurrent                                                     Overvoltage protection                                Chassis Cooling    Per slot cooling                                            Slot airflow direction                                   Module cooling    Intake  eee e              tpe cns    Power supply cooling    NI PXI 1031 PXI 1031DC User Manual A 6    All outputs protected from short  circuit and overload    All outputs protected from  overvoltage  Cycle the primary  power and front power switch to  restart     25W    P1 to P2  bottom of module  to top of module    Forced air circulation  positive  pressurization  through a High  Flow fan with HIGH AUTO  speed selector    Bottom of chassis    Along rear  right side  and top of  chassis    Forced air circulation through  integrated fan    Front side of chassis    Rear side of chassis    ni com    Appendix A Specifications    Environmental   Operating                                                  Indoor use   Maximum   1                                    5       2 000 m   Installation                                                II   Pollution Degree                                      2   Operating Environment   Ambient temperature range                     0 
11.   interior cleaning  3 2  preparation  3 1  service interval  3 1  static discharge damage  caution   3 1  maintenance of PXI 1031DC  3 1  cleaning  exterior cleaning  3 2  fan filter  3 2  interior cleaning  3 2  preparation  3 1  service interval  3 1  static discharge damage  caution   3 1    National Instruments support and  services  C 1    0    optional equipment  1 5    P    P1  J1  connector  peripheral slot  table   B 6  star trigger slot  table   B 4  system controller slot  table   B 2  P2  J2  connector  peripheral slot  table   B 7  star trigger slot  table   B 5  system controller slot  table   B 3  peripheral slots  overview  1 7  P1  J1  connector pinouts  table   B 6  P2  J2  connector pinouts  table   B 7    ni com    pinouts  B 1        J1  connector  peripheral slot  table   B 6  star trigger slot  table   B 4  system controller slot  table   B 2  P2  J2  connector  peripheral slot  table   B 7  star trigger slot  table   B 5  system controller slot  table   B 3  power cables  table   1 2  power supply  connecting to  2 4  connecting to DC  2 5  power switch  2 5  power up  testing  2 4  programming examples  NI resources   C 1  PXI controller  2 6  installing in a PXI 1031 chassis   figure   2 8  installing in a PXI 1031DC chassis   figure   2 8  PXI subsystem  star trigger and local bus routing   figure   1 8  PXI_CLK10  1 8  PXI CLKIO IN pin  1 8  PXI 1031  backplane  interoperability with  CompactPCI  1 6  local bus  1 7  overview  1 6  peripheral slot
12.  Certification column     Backplane    up     3U sized  one system slot   with three system expansion  slots  and three peripheral slots   Compliant with IEEE 1101 10  mechanical packaging   PXI Hardware Specification  compliant  Accepts both PXI  and CompactPCI 3U modules          DC input exempt from emissions requirements         National Instruments Corporation A 9 NI PXI 1031 PXI 1031DC User Manual    Appendix A Specifications    bio   5 V  Backplane bare board material                UL 94 V 0 recognized  Backplane connectors                               Conform to IEC 917 and    IEC 1076 4 101  and are  UL 94 V 0 rated    10 MHz System Reference Clock  10 MHz REF     Maximum clock skew  between 61016                  1 ns    Built in 10 MHz clock    IACCUFACY eerie eti ee retos  100 ppm  guaranteed over the  operating temperature range     Mechanical  Overall dimensions  standard chassis   H  ighit     iere rtr ntn 177 mm  6 97 in      hy  Note 12 7 mm  0 50 in   is added to height when feet are installed     Width          eee tires 257 1 mm  10 12 in     Depth ss ecrit 212 8 mm  8 38 in     Weight         5 kg  11 0 165   Chassis materials          2 20   222    Sheet Aluminum     Extruded Aluminum   Cold Rolled Steel  Nylon    ITI Sse                            seeds canes Clear Chromate Conversion  Coat on Aluminum  Electrodeposited Nickel Plate  Plate on Cold Rolled Steel  Polyester Urethane Powder Paint         V I O  is connected to the  5 V DC power plane  so 
13.  The information in this file is combined with information about        National Instruments Corporation 2 11 NI PXI 1031 PXI 1031DC User Manual    Chapter 2    Installation and Configuration    the system controller to create a single system initialization file called  pxisys ini  PXI System Initialization   The system controller  manufacturer either provides a pxisys  ini file for the particular chassis  model that contains the system controller or provides a utility that can  read an arbitrary chassis  ini file and generate the corresponding  pxisys ini file  System controllers from National Instruments use  MAX to generate the pxisys ini file from the chassis  ini file     Device drivers and other utility software read the pxisys ini file to  obtain system information  Device drivers should have no need to directly  read the chassis ini file  For detailed information regarding  initialization files  refer to the PXI specification at www pxisa org     NI PXI 1031 PXI 1031DC User Manual 2 12 ni com       Maintenance    This chapter describes basic maintenance procedures you can perform on  the PXI 1031 and PXI 1031DC chassis     UN Caution Disconnect the power cables prior to servicing the chassis     DC Fuse Replacement  PXI 1031DC Only     The PXI 1031DC is protected against over current by a 30 A fuse on the  rear of the chassis  as shown in Figure 1 3  Rear View of the PXI 1031DC  Chassis  The fuse should only be replaced with a Wickmann 162 6385 530   Littlefuse 257 03
14.  circulation through  integrated fan    Front side of chassis    Rear side of chassis    0 to 50   C  Tested in accordance  with IEC 60068 2 1 and  IEC 60068 2 2      10 to 90   noncondensing   Tested in accordance with  IEC 60068 2 56         20 to 70   C  Tested in  accordance with IEC 60068 2 1  and IEC 60068 2 2      5 to 9596  noncondensing   Tested in accordance with  IEC 60068 2 56      30 g peak  half sine  11 ms pulse   Tested in accordance with  IEC 60068 2 27  Test profile  developed in accordance with  MIL PRF 28800F      NI PXI 1031 PXI 1031DC User Manual    Appendix A Specifications    Random Vibration   Operating                   ceri oe 5 to 500 Hz  0 3 Sims                                  2  42222  5 to 500     2 4      Tested in accordance with  IEC 60068 2 64  Nonoperating  test profile exceeds the    requirements of  MIL PRF 28800F  Class 3      Acoustic Emissions    Sound Pressure Level  at Operator Position    Tested in accordance with ISO 7779      PXI 1031  Auto fan  at 25   C ambient               40 7 dBA  High           49 4 dBA    Sound Power   Tested in accordance with ISO 7779      PXI 1031  Auto fan  at 25   C ambient               51 8 dBA  i fain ss         sn 57 5 dBA    PXI 1031DC Chassis       Electrical  AC Input  Input voltage range                                   100 120 200 240 VAC  Operating voltage range  2222222    90 132 180 264 VAC  Input frequency                      eee 50 60 Hz  Operating frequency range                    
15.  the rear of  chassis labeled 10 MHz REF OUT  The system reference clock can be used  for synchronization of multiple modules in a measurement or control  system  The 10 MHz REF IN and OUT BNC connectors on the rear of the  chassis can be used to synchronize multiple chassis to one reference clock   The PXI backplane specification defines implementation guidelines for  PXI_CLK10     Transistor transistor logic    Underwriter   s Laboratories    Volts  Volts alternating current  or Vins    Peak to peak voltage    Watts    NI PXI 1031 PXI 1031DC User Manual G 6 ni com    Index       A    AC power cables  table   1 2    backplane  interoperability with CompactPCI  1 6  local bus  1 7  overview  1 6  peripheral slots  1 7  specifications  A 9  star trigger  ST  slot  1 7  system reference clock  1 8  trigger bus  1 8          cables  power  table   1 2  calibration certificate  NI resources   C 2  chassis initialization file  2 11  CompactPCI  installing modules  figure   2 9  interoperability with PXI 1031  backplane  1 6  interoperability with PXI 1031DC  backplane  1 6  configuration  See installation  configuration   and operation  conventions used in the manual  vii  cooling  air cooling of PXI 1031  2 2  air cooling of PXI 1031DC  2 2  air intake  figure   2 3  filler panel installation  2 3  setting fan speed  2 3       National Instruments Corporation    D    DC   power cable  1 6   power up  testing  2 5  Declaration of Conformity  NI resources   C 1  diagnostic tools  N
16. 0  or equivalent  To remove the fuse  pull straight out  from the chassis        Service Interval       Clean the chassis fan filter at a maximum interval of six months   Depending on the amount of use and ambient dust levels in the operating  environment  the filter may require more frequent cleaning     Clean dust from the chassis exterior  and interior  as needed  based on the  operating environment  Periodic cleaning increases reliability     Preparation       The information in this chapter is designed for use by qualified service  personnel  Read the Read Me First  Safety and Radio Frequency  Interference document included with your kit before attempting any  procedures in this chapter         Caution          components within the chassis are susceptible to static discharge damage   Service the chassis only in a static free environment  Observe standard handling  precautions for static sensitive devices while servicing the chassis  Always wear a  grounded wrist strap or equivalent while servicing the chassis        National Instruments Corporation 3 1 NI PXI 1031 PXI 1031DC User Manual    Chapter 3 Maintenance    Cleaning       UN Caution Always disconnect the AC power cable  and the DC power cable  if you are  working with a PXI 1031DC chassis  before cleaning or servicing the chassis     Interior Cleaning    Exterior Cleaning    Cleaning procedures consist of exterior and interior cleaning of the chassis  and cleaning the fan filter  Refer to your module user documen
17. 1  Using System Configuration and Initialization Files                            eee 2 11  Chapter 3  Maintenance  DC Fuse Replacement  PXI 1031DC                       3 1  service Interval             AOI Gu n E ER E ER Ee pie        aay 3 1  Preparation               Ete eH He FORAS 3 1  Cleaning    sonet ee ee etie t mo Red aeui 3 2  Interior Cleaning              td etse tee 3 2  Exterior Cleaning    uie Ote ee on EU d ne Et 3 2  Cleaning and Replacing the Fan                           3 2  Appendix A  Specifications  Appendix B  Pinouts  Appendix C  Technical Support and Professional Services  Glossary  Index    NI PXI 1031 PXI 1031DC User Manual vi ni com    About This Manual       Conventions           NI        103 1        1031     User Manual contains information about  installing  configuring  using  and maintaining the NI PXI 1031 and  PXI 1031DC chassis              Pg    bold    italic    monospace    The following conventions are used in this manual     The    symbol leads you through nested menu items and dialog box options  to a final action  The sequence File  Page Setup  Options directs you to  pull down the File menu  select the Page Setup item  and select Options  from the last dialog box     This icon denotes a note  which alerts you to important information     This icon denotes a caution  which advises you of precautions to take to  avoid injury  data loss  or a system crash  When this symbol is marked on  the product  refer to the Read Me First  Saf
18. 1 connectors meet the requirements of the  CompactPCI specification for both peripheral and system modules  Refer  to Appendix B  Pinouts  for pinout information     The PXI specific signals are on the backplane P2 connectors and are  found only on those signal lines reserved or not used in the CompactPCI  64 bit specification  Therefore  all modules that meet the requirements  of the CompactPCI 64 bit specification will function in the  PXI 1031 PXI 1031DC  Refer to Appendix B  Pinouts  for pinout  information     The chassis backplane has  5 V V I O   Refer to the CompactPCI  Specification PICMG 2 0 R 3 0 for details regarding V I O      System Controller Slot    The system controller slot is slot 1 of the chassis as defined by the PXI  specification  It has three controller expansion slots for system controller  modules that are wider than one slot  As defined in the PXI specification   these slots allow the controller to expand to the left to prevent the controller  from using peripheral slots     NI PXI 1031 PXI 1031DC User Manual 1 6 ni com    Chapter 1 Getting Started    Star Trigger Slot    The star trigger  ST  slot is slot 2  This slot has dedicated equal length  trigger lines between slot 2 and peripheral slots 3 and 4  refer to   Figure 1 5   Slot 2 is intended for modules with ST functionality that can  provide individual triggers to all other peripheral modules  However  if you  do not require advanced trigger functionality  you can install any standard  periphe
19. 1031DC User Manual    Chapter 2     Installation and Configuration    Rack Mounting       Rack mount applications require the optional rack mount kits available  from National Instruments  Refer to Figure A 3  PXI 103 I PXI 1031DC  Rack Mount Kit Components  and the instructions supplied with the rack  mount kits to install your chassis in an instrument rack         Note You may want to remove the feet from the chassis when rack mounting  To do so   remove the screws holding the feet in place     Connecting Safety Ground       J Caution The PXI 1031 PXI 1031DC chassis is designed with a three position inlet that  connects the cord set ground line to the chassis ground  To minimize shock hazard  make  sure the electrical power outlet you use to power the chassis has an appropriate earth safety  ground     For DC powered applications  or if your power outlet does not have an  appropriate ground connection  you must connect the premise safety  ground to the chassis grounding screw located on the rear panel  Refer to  Figure 1 2  Rear View of the PXI 1031 Chassis  or Figure 1 3  Rear View  of the PXI 1031DC Chassis  to locate the chassis grounding screw   Complete the following steps to connect the safety ground     1  Connect    10 AWG  2 6 mm  wire to the chassis grounding screw  using a grounding lug  The wire must have green insulation with a  yellow stripe or must be noninsulated  bare      2  Attach the opposite end of the wire to permanent earth ground using  toothed washe
20. AD 26  GND V O  AD 25  AD 24  GND  7 GND AD 30  AD 29  AD 28  GND AD 27  GND  6 GND REQ  GND 3 3V CLK      31  GND     GND               5 BRSVPIB5 RST  GND GNT  GND    GND     5        4 GND V I O  INTP INTS GND  3 GND INTA  INTB  INTC  5V INTD  GND  2 GND TCK 5V TMS TDO TDI GND  1 GND 5V  12V TRST   12V 5V GND                                        NI PXI 1031 PXI 1031DC User Manual B 2 ni com    Appendix B Pinouts    Table    2  P2  J2  Connector Pinout for the System Controller Slot                                                                                                                   Pin Z A B C D E F  22 GND GA4 GA3 GA2     1        GND  21 GND CLK6 GND RSV RSV RSV GND  20 GND CLK5 GND RSV GND RSV GND  19 GND GND GND RSV RSV RSV GND  18 GND PXI TRIG3                4        TRIG5 GND                6 GND  17 GND                2 GND RSV REQ6  GNT6  GND  16 GND                          TRIGO RSV GND        TRIG7 GND  15 GND                  15   GND RSV REQS        5  GND  14 GND AD 35 AD 34 AD 33 GND AD 32 GND  13 GND AD 38 GND         AD 37 AD 36 GND  12 GND AD 42 AD 41 AD 40 GND AD 39 GND  11 GND AD 45 GND         AD 44 AD 43 GND  10 GND AD 49 AD 48 AD 47 GND AD 46 GND  9 GND AD 52 GND         AD 51 AD 50 GND  8 GND AD 56 AD 55 AD 54 GND AD 53 GND  7 GND AD 59 GND V I O  AD 58 AD 57 GND  6 GND AD 63 AD 62 AD 61 GND AD 60 GND  5 GND         5   GND V I O  C BE 4   PAR64 GND  4 GND V O  PXI_BRSVB4   C BE 7   GND C BE 6   GND  3 GND CLK4 GND GNT3  REQ4  GNT4  G
21. F  RELIABILITY SUITABLE FOR USE IN OR IN CONNECTION WITH SURGICAL IMPLANTS OR AS CRITICAL COMPONENTS IN  ANY LIFE SUPPORT SYSTEMS WHOSE FAILURE TO PERFORM CAN REASONABLY BE EXPECTED TO CAUSE SIGNIFICANT  INJURY TO A HUMAN      2  IN ANY APPLICATION  INCLUDING THE ABOVE  RELIABILITY OF OPERATION OF THE SOFTWARE PRODUCTS CAN BE  IMPAIRED BY ADVERSE FACTORS  INCLUDING BUT NOT LIMITED TO FLUCTUATIONS IN ELECTRICAL POWER SUPPLY   COMPUTER HARDWARE MALFUNCTIONS  COMPUTER OPERATING SYSTEM SOFTWARE FITNESS  FITNESS OF COMPILERS  AND DEVELOPMENT SOFTWARE USED TO DEVELOP AN APPLICATION  INSTALLATION ERRORS  SOFTWARE AND  HARDWARE COMPATIBILITY PROBLEMS  MALFUNCTIONS OR FAILURES OF ELECTRONIC MONITORING OR CONTROL  DEVICES  TRANSIENT FAILURES OF ELECTRONIC SYSTEMS  HARDWARE AND OR SOFTWARE   UNANTICIPATED USES OR  MISUSES  OR ERRORS ON THE PART OF THE USER OR APPLICATIONS DESIGNER  ADVERSE FACTORS SUCH AS THESE ARE  HEREAFTER COLLECTIVELY TERMED    SYSTEM FAILURES      ANY APPLICATION WHERE A SYSTEM FAILURE WOULD  CREATE A RISK OF HARM TO PROPERTY OR PERSONS  INCLUDING THE RISK OF BODILY INJURY AND DEATH  SHOULD  NOT BE RELIANT SOLELY UPON ONE FORM OF ELECTRONIC SYSTEM DUE TO THE RISK OF SYSTEM FAILURE  TO AVOID  DAMAGE  INJURY  OR DEATH  THE USER OR APPLICATION DESIGNER MUST TAKE REASONABLY PRUDENT STEPS TO  PROTECT AGAINST SYSTEM FAILURES  INCLUDING BUT NOT LIMITED TO BACK UP OR SHUT DOWN MECHANISMS   BECAUSE EACH END USER SYSTEM IS CUSTOMIZED AND DIFFERS FROM NATIONAL INSTRUMENTS  TE
22. I resources   C 1  dimensions  figure   A 11  A 12  documentation   conventions used in manual  vii   NI resources  C 1   related documentation  viii  drivers  NI resources   C 1    E    electromagnetic compatibility  A 9  EMC filler panel kit  1 5  examples  NI resources   C 1    F    fan  setting speed  2 3  filler panel installation  2 3    G    ground  connecting  2 4    H    handle feet kit  1 5  help  technical support  C 1    NI PXI 1031 PXI 1031DC User Manual    Index    installation  configuration  and operation  chassis initialization file  2 11  configuration in MAX  figure   2 10  connecting safety ground  2 4  filler panel installation  2 3  installing a PXI controller  2 6  module installation  2 7  2 8  CompactPCI or PXI modules   figure   2 9  injector ejector handle position   figure   2 7         configuration in MAX  2 9  trigger configuration  2 11         controller installed in a PXI 1031  chassis  figure   2 8         controller installed in a PXI 1031DC  chassis  figure   2 8  rack mounting  2 4  setting fan speed  2 3  site considerations  2 2  testing power up  2 4  DC  2 5  unpacking  PXI 1031  1 1  PXI 1031DC  1 1  instrument drivers  NI resources   C 1  interoperability with CompactPCI  1 6    K    key features  1 2  KnowledgeBase  C 1    L    local bus  routing  figure   1 7  star trigger and local bus routing   figure   1 8    NI PXI 1031 PXI 1031DC User Manual    maintenance of        1031  3 1  cleaning  exterior cleaning  3 2  fan filter  3 2
23. IG3                4                5 GND PXI_TRIG6 GND  17 GND   PXI_TRIG2 GND RSV PXI STAR PXI_CLK10 GND  16 GND                            TRIGO RSV GND PXI_TRIG7 GND  15 GND   PXI BRSVAIS   GND RSV PXI_LBL6 PXI_LBR6 GND  14 GND   AD 35 AD 34  AD 33 GND AD 32 GND  13 GND   AD 38 GND         AD 37 AD 36 GND  12 GND   AD 42 AD 41  AD 40 GND AD 39 GND  11 GND   AD 45 GND V I O  AD 44 AD 43 GND  10 GND   AD 49 AD 48  AD 47 GND AD 46 GND  9 GND   AD 52 GND V I O  AD 51 AD 50 GND  8 GND   AD 56 AD 55  AD 54 GND AD 53 GND  7 GND   AD 59 GND         AD 58 AD 57 GND  6 GND   AD 63 AD 62  AD 61 GND AD 60 GND  5 GND   C BE 5   GND         C BE 4   PAR64 GND  4 GND           PXI_BRSVB4 C BE 7   GND C BE 6   GND  3 GND   PXI_LBR7 GND PXI_LBR8 PXI_LBR9 PXI LBR10 GND  2 GND   PXI LBRII PXI LBR12 UNC PXI LBL7 PXI_LBL8 GND  1 GND   PXI LBL9 GND PXI_LBL10 PXI LBL11 PXI LBL12 GND                             National Instruments Corporation B 7 NI PXI 1031 PXI 1031DC User Manual       Technical Support and  Professional Services    Visit the following sections of the National Instruments Web site at  ni com for technical support and professional services        National Instruments Corporation    Support   Online technical support resources at ni com support  include the following         Self Help Resources   For answers and solutions  visit the  award winning National Instruments Web site for software drivers  and updates  a searchable KnowledgeBase  product manuals   step by step troublesh
24. Instruments Corporation G 5    Glossary    National Instruments driver that controls the operation of National  Instruments data acquisition  DAQ  devices    National Instruments implementation of the VISA  Virtual Instrument  System Architecture  I O standard  NI VISA provides support for the  VISA API  and also provides VISAIC  a utility for instrument  configuration and I O function execution     Nanosecond  one billionth of a second  10 9     Parts per million    PCI eXtensions for Instrumentation  PXI is an implementation of  CompactPCI with added electrical features that meet the high performance  requirements of instrumentation applications by providing triggering  local  buses  and system clock capabilities     10 MHz PXI system reference clock    Root mean square    Seconds  Deviation in signal transmission times    An assembly installed into an empty slot to improve the airflow in adjacent  slots    Star trigger    The backplane is unpowered  off   but the chassis is still connected to  AC power mains     NI PXI 1031 PXI 1031DC User Manual    Glossary    star trigger slot    system reference  clock    TTL    UL    VAC            This slot is located at slot 2        has a dedicated trigger line between each  peripheral slot  Use this slot for a module with ST functionality that can  provide individual triggers to all other peripherals     A 10 MHz clock  also called PXI_CLK10  that is distributed to all  peripheral slots in the chassis  as well as a BNC connector on
25. ND  2 GND CLK2 CLK3 SYSEN  GNT2  REQ3  GND  1 GND CLKI GND       1  GNT1  REQ2  GND                                              National Instruments Corporation B 3 NI PXI 1031 PXI 1031DC User Manual    Appendix B Pinouts    Table B 3  P1  J1  Connector Pinout for the Star Trigger Slot                                                                                        Pin Z A B    D E F  25 GND 5V REQ64  ENUM  3 3V 5V GND  24 GND AD 1  5V V I O  AD 0          4  GND  23 GND 3 3V AD 4  AD 3  5V AD 2  GND  22 GND AD 7  GND 3 3V AD 6  AD 5  GND  21 GND 3 3V AD 9  AD 8  M66EN C BE 0   GND  20 GND AD 12  GND V I O  AD 11  AD 10  GND  19 GND 3 3V AD 15  AD 14  GND AD 13  GND  18 GND SERR  GND 3 3V PAR C BE 1   GND  17 GND 3 3V SDONE SBO  GND PERR  GND  16 GND DEVSEL  GND V I O  STOP  LOCK  GND  15 GND 3 3V FRAME  IRDY  GND TRDY  GND   12 14 Key Area   11 GND AD 18  AD 17  AD 16  GND C BE 2   GND  10 GND AD 21  GND 3 3V AD 20  AD 19  GND  9 GND C BE 3   IDSEL AD 23  GND AD 22  GND  8 GND AD 26  GND         AD 25  AD 24  GND  7 GND AD 30  AD 29  AD 28  GND AD 27  GND  6 GND REQ  GND 3 3V CLK AD 31  GND  5 GND BRSVPIA5 BRSVPIB5 RST  GND GNT  GND  4 GND               4 GND V I O  INTP INTS GND  3 GND INTA  INTB  INTC  5V INTD  GND  2 GND TCK 5V TMS TDO TDI GND  1 GND 5V  12V TRST   12V 5V GND                                        NI PXI 1031 PXI 1031DC User Manual B 4 ni com    Appendix B Pinouts    Table B 4  P2  J2  Connector Pinout for the Star Trigger Slot                     
26. Part Replacement   Only service this equipment with parts that are  exact replacements  both electrically and mechanically  Contact  National Instruments for replacement part information  Installation of  parts with those that are not direct replacements may cause harm to  personnel operating the chassis  Furthermore  damage or fire may  occur if replacement parts are unsuitable     e  Modification   Do not modify any part of the chassis from its original  condition  Unsuitable modifications may result in safety hazards     Chassis Cooling Considerations       The chassis is designed to operate on a bench or in an instrument rack   Determine how you want to use the chassis and follow the appropriate  installation instructions     Providing Adequate Clearance    Apertures in the top  bottom  front  rear  and along the right side of the  chassis facilitate power supply and module cooling  Air enters through  filters and fan inlet in the bottom of the chassis for module cooling  It then  exits through the upper sections at the right side  back  and through the top   as shown in Figure 2 1  Air cooling the power supply enters the front of the  chassis  which is shown in Figure 1 1  Front View of the PXI 1031 Chassis   then exits through the rear of the chassis  which is shown in Figure 1 2   Rear View of the PXI 1031 Chassis  and Figure 1 3  Rear View of the  PXI 1031DC Chassis  Place the chassis on a bench top or in an instrument  rack so that the fans  air inlets  and the air o
27. STING  PLATFORMS AND BECAUSE A USER OR APPLICATION DESIGNER MAY USE NATIONAL INSTRUMENTS PRODUCTS IN  COMBINATION WITH OTHER PRODUCTS IN A MANNER NOT EVALUATED OR CONTEMPLATED BY NATIONAL  INSTRUMENTS  THE USER OR APPLICATION DESIGNER IS ULTIMATELY RESPONSIBLE FOR VERIFYING AND VALIDATING  THE SUITABILITY OF NATIONAL INSTRUMENTS PRODUCTS WHENEVER NATIONAL INSTRUMENTS PRODUCTS ARE  INCORPORATED IN A SYSTEM OR APPLICATION  INCLUDING  WITHOUT LIMITATION  THE APPROPRIATE DESIGN   PROCESS AND SAFETY LEVEL OF SUCH SYSTEM OR APPLICATION     Contents       About This Manual     EBO 35555 bss as e ces acces esta           ERR a                              Vil  Related                                                                 Vili    Chapter 1  Getting Started                                                                                                                        ae ve bees 1 1  What You Need  to Get Started            nene mere epe eres 1 1  Ky Features sc  i edere Re er e E AREE RR 1 2  Chassis Description    ete teer tee eid etes re cie Penis 1 3  Optional Equipment    cioe ende eae teet DR Iii edet ER etae Eden 1 5         Filler  Panels          Ceetuma tee UPC e 1 5  Rack Mount Kits    en eH HER HEH RM      Ep 1 5  Handle Feet Kit          tte ec te pta tine pes 1 5  DC Power Cable  PXI 1031DC Only                        esee 1 6  PXI 1031 PXT 1031DC Backplane                                    ee 1 6  Interoperability with                        2    22     
28. XI System Configuration    Refer to Figure 2 6 while completing the following steps     NI PXI 1031 PXI 1031DC User Manual    1   2     Launch MAX     In the Configuration tree  click the Devices and Interfaces branch to  expand it     If the PXI system controller has not yet been configured  it will be  labeled PXI System  Unidentified   Right click this entry to  display the context menu and then select the appropriate controller  model from the Identify As submenu     Click the PXI System controller  and the chassis  or multiple chassis   in a multi chassis configuration  will be listed below it  Identify each  chassis by right clicking its entry and then selecting the appropriate  chassis model through the Identify As submenu  Further expanding  the PXI System branch will show all of the devices in the system that  can be recognized by NI VISA  After your controller and all of your  chassis have been identified  the required pxisys ini file will be  complete     2 10 ni com    Chapter 2 Installation and Configuration    5  Apply the chassis number labels  shown in Figure 2 7  included with  your kit to each chassis in your PXI system  and write in the chassis  number accordingly in the white space     Chassis         Number    Figure 2 7  Chassis Number Label                Trigger Configuration in MAX    Each chassis has one or more trigger buses  each with eight lines numbered  0 through 7 that can be reserved and routed statically or dynamically  Static  reservation   
29. d grounds the chassis and  protects it from electrical damage while you install the controller  For  DC powered applications  make sure the chassis is properly grounded  through the chassis ground screw  Make sure the chassis power switch  is in the Off  Standby  position     VAN Caution To protect both yourself and the chassis from electrical hazards  leave the chassis  off until you finish installing the controller     NI PXI 1031 PXI 1031DC User Manual 2 6 ni com    Chapter 2 Installation and Configuration    Install the controller into the system controller slot  slot 1  indicated by  the red card guides  by first placing the controller edges into the front  controller guides  top and bottom   Slide the controller to the rear of  the chassis  making sure that the injector ejector handle is pushed  down as shown in Figure 2 3                                                                        National Instruments Corporation    Figure 2 3  Injector Ejector Handle Position during Controller  or Peripheral Module Insertion    When you begin to feel resistance  push up on the injector ejector  handle to inject the controller fully into the chassis frame  Secure the  controller front panel to the chassis using the controller front panel  mounting screws     Connect the keyboard  mouse  and monitor to the appropriate  connectors  Connect devices to ports as required by your system  configuration     Power on the chassis  Verify that the controller boots  If the controller  d
30. dle    4 PXI Module    3     1031DC Chassis    PXI 1031 PXI    1    2    Injector Ejector Rail          Installing PX  or CompactPCI Modules     5   th           Figure 2    ion wi    t    igura           System Conf       Configuration of the PXI system is handled through Measurement  amp   Automation Explorer  MAX   included on the NI Driver CD ROM    packaged with your kit  MAX creates the pxisys   ini file that defines the    layout and parameters of your PXI system  After installing the software on    the NI Driver CD ROM    the MAX icon will be present on the desktop  The         configuration steps for single or multiple chassis systems are the same     NI PXI 1031 PXI 1031DC User Manual    2 9        National Instruments Corporation    Chapter 2 Installation and Configuration       Eile Edit view Tools Help    X Chassis 1  PXI 1031    Measurement  amp  Automation Explorer   inl xi          E  x  My System  m  Data Neighborhood  E Bg  Devices and Interfaces  H E Traditional NI DAQ Devices   9 88 NI DAQmx Devices   5 PXI PXI System  External PC          PX12  13  1N5TR  Bl  P312  14 1NSTR     Ports  Serial  amp  Parallel   EIX VXI System 0  PXI 8320     3 Scales    Software       MI Drivers         Remote Systems          Configuration 4   3P Show Help          Slot   Device    1 PXI PXI Bridge  NI PXI MXI 3  from PXI System  External PC    2 B PXI2 15 INSTR   3 BR PXI2 14 INSTR    4 H   PXIZ 13 INSTR                   Figure 2 6  Chassis Configuration in MAX    Basic P
31. document has been carefully reviewed for technical  accuracy  In the event that technical or typographical errors exist  National Instruments reserves the right to make changes to subsequent  editions of this document without prior notice to holders of this edition  The reader should consult National Instruments if errors are suspected   In no event shall National Instruments be liable for any damages arising out of or related to this document or the information contained in it     EXCEPT AS SPECIFIED HEREIN  NATIONAL INSTRUMENTS MAKES NO WARRANTIES  EXPRESS OR IMPLIED  AND SPECIFICALLY DISCLAIMS ANY WARRANTY OF  MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE  CUSTOMER   S RIGHT TO RECOVER DAMAGES CAUSED BY FAULT OR NEGLIGENCE ON THE PART OF  NATIONAL INSTRUMENTS SHALL BE LIMITED TO THE AMOUNT THERETOFORE PAID BY THE CUSTOMER  NATIONAL INSTRUMENTS WILL NOT BE LIABLE FOR  DAMAGES RESULTING FROM LOSS OF DATA  PROFITS  USE OF PRODUCTS  OR INCIDENTAL OR CONSEQUENTIAL DAMAGES  EVEN IF ADVISED OF THE POSSIBILITY  THEREOF  This limitation of the liability of National Instruments will apply regardless of the form of action  whether in contract or tort  including  negligence  Any action against National Instruments must be brought within one year after the cause of action accrues  National Instruments  shall not be liable for any delay in performance due to causes beyond its reasonable control  The warranty provided herein does not cover  damages  defects  malfunctions  or servic
32. e failures caused by owner   s failure to follow the National Instruments installation  operation  or  maintenance instructions  owner   s modification of the product  owner   s abuse  misuse  or negligent acts  and power failure or surges  fire   flood  accident  actions of third parties  or other events outside reasonable control     Copyright   Under the copyright laws  this publication may not be reproduced or transmitted in any form  electronic or mechanical  including photocopying   recording  storing in an information retrieval system  or translating  in whole or in part  without the prior written consent of National  Instruments Corporation     Trademarks    National Instruments     National Instruments Alliance Partner     NI     ni com     NI DAQ     and NI VISA    are trademarks of  National Instruments Corporation     Product and company names mentioned herein are trademarks or trade names of their respective companies     Members of the National Instruments Alliance Partner Program are business entities independent from National Instruments and have no  agency  partnership  or joint venture relationship with National Instruments     Patents    For patents covering National Instruments products  refer to the appropriate location  Help  Patents in your software  the patents txt file  on your CD  or ni com patents     WARNING REGARDING USE OF NATIONAL INSTRUMENTS PRODUCTS     1  NATIONAL INSTRUMENTS PRODUCTS ARE NOT DESIGNED WITH COMPONENTS AND TESTING FOR A LEVEL O
33. ed using the criteria of  EN 61010 1 and meets the requirements of the following standards for  safety and electrical equipment for measurement  control  and  laboratory use     e EN 61010 1  IEC 61010 1  e UL61010 1  e CAN CSA C22 2 No  61010 1    NI PXI 1031 PXI 1031DC User Manual A 8 ni com    Appendix A Specifications      Note For UL and other safety certifications  refer to the product label  or visit  ni com certification  search by model number or product line  and click the  appropriate link in the Certification column     Electromagnetic Compatibility    Emissions                0   nnne EN 55011 Class A at 10 m  FCC Part 15A above 1 GHz     Immunity                 eie e Eee gn EN 61326 1997   A2 2001   Table 1  EMC EMII                ee CE  C Tick  and FCC Part 15     Class A  Compliant    iyi Note For EMC compliance  operate this device with shielded cabling  In addition   all covers and filler panels must be installed     CE Compliance    This product meets the essential requirements of applicable European  Directives  as amended for CE marking  as follows     Low Voltage Directive  safety                73 23 EEC    Electromagnetic Compatibility  Directive                       eee 89 336 EEC    iyi Note Refer to the Declaration of Conformity  DoC  for this product for any additional  regulatory compliance information  To obtain the DoC for this product  visit  ni com certification  search by model number or product line  and click the  appropriate link in the
34. ety and Radio Frequency  Interference document  shipped with the product  for precautions to take     Bold text denotes items that you must select or click in the software  such  as menu items and dialog box options  Bold text also denotes parameter  names     Italic text denotes variables  emphasis  a cross reference  a hardware label   or an introduction to a key concept  This font also denotes text that is a  placeholder for a word or value that you must supply     Text in this font denotes text or characters that you should enter from the  keyboard  sections of code  programming examples  and syntax examples   This font is also used for the proper names of disk drives  paths  directories   programs  subprograms  subroutines  device names  functions  operations   variables  filenames  and extensions         National Instruments Corporation      NI PXI 1031 PXI 1031DC User Manual    About This Manual    Related Documentation       The following documents contain information that you might find helpful  as you read this manual     e   NI PXI 1031DC DC Cable Kit Installation Guide  e CompactPCI Specification PICMG 2 0 R 3 0   e PXI Hardware Specification   e PXI Software Specification    e   EEE 1101 1 1991  IEEE Standard for Mechanical Core  Specifications for Microcomputers Using IEC 603 2 Connectors        EEE 1101 10  ZEEE Standard for Additional Mechanical  Specifications for Microcomputers Using IEEE 1101 1 Equipment  Practice    NI PXI 1031 PXI 1031DC User Manual viii 
35. h types of chassis will be  identical on the bottom          D                   e    NATIONAL    INSTRUMENTS    NI PXI 1031                                         after           4                                                                                                                       9   STANDBY                               akon       Controller Expansion Slots    Captive Screw   PXI Filler Panel  PXI Backplane   Rubber Foot    6 PXI Expansion Slots   7 Star Trigger Peripheral Slot   8 Embedded Controller Slot   9 Power Switch  Standby    10 Power Supply Airflow Intake Vents              National Instruments Corporation    Figure 1 1  Front View of the PXI 1031 Chassis    1 3    NI PXI 1031 PXI 1031DC User Manual    Chapter 1 Getting Started                                 9 e                                  1 Rear Exhaust Vents 4 Chassis Ground Screw  2 AC Input 5 Fan Speed Selector Switch  3 Power Supply Fan Exhaust 6 Rubber Foot       Figure 1 2  Rear View of the PXI 1031 Chassis                                              POWER FROM UNIT                               1 Rear Exhaust Vents 5 Power Supply Fan Exhaust   2 DC Fuse Socket 6 Chassis Ground Screw   3 DC Input 7 AUTO HIGH Fan Speed Selector Switch  4 AC Input 8 Rubber Foot             Figure 1 3  Rear View of the PXI 1031DC Chassis    NI PXI 1031 PXI 1031DC User Manual 1 4 ni com       Chapter 1 Getting Started                                                                                      
36. he items listed in Table 1 1  or if you have the  incorrect AC power cable  contact National Instruments     You have the option of powering the PXI 1031DC chassis with a DC  power cable through the DC input connector on the rear panel of the    chassis  Refer to Figure 1 3 for the location of the DC connector     Key Features       The PXI 1031 PXI 1031DC combines a 4 slot PXI backplane with a    structural design that has been optimized for maximum usability in a wide  range of applications     The key features of the chassis include the following     Accepts 3U PXI and CompactPCI  PICMG 2 0 R 3 0  modules    4 slot chassis with universal AC input  and automatic    voltage frequency ranging    DC power input  PXI 1031DC only   On Off  Standby  power switch on the front panel for easy access    AUTO HIGH temperature controlled fan speed based on air intake  temperature to minimize audible noise     Optional  Carrying handle for portability    Rack mountable    NI PXI 1031 PXI 1031DC User Manual 1 2    ni com    Chassis Description    Chapter 1 Getting Started       Figure 1 1  Figure 1 2  and Figure 1 3 show the key features of the  PXI 1031 PXI 1031DC chassis front and rear panels  Figure 1 1 shows the  front view of the PXI 1031  the PXI 1031DC front panel is identical except  for the chassis name stenciled on the face plate   Figure 1 2 shows the rear  view of the PXI 1031  Figure 1 3 shows the rear panel of the PXI 1031DC   Figure 1 4 shows the bottom of the chassis  bot
37. l Bus Routing    Trigger Bus    All slots share eight PXI trigger lines  You can use these trigger lines  in a variety of ways  For example  you can use triggers to synchronize  the operation of several different PXI peripheral modules  In other  applications  one module located in slot 2 can control carefully timed  sequences of operations performed on other modules in the system   Modules can pass triggers to one another  allowing precisely timed  responses to asynchronous external events the system is monitoring  or controlling     System Reference Clock    The PXI 1031 PXI 1031DC supplies the PXI 10 MHz system clock signal   PXI_CLK10  independently to each peripheral slot  An independent  buffer  having a source impedance matched to the backplane and a skew of  less than 1 ns between slots  drives the clock signal to each peripheral slot   You can use this common reference clock signal to synchronize multiple  modules in a measurement or control system  You can drive PXI_CLK10  from an external source through the PXI_CLK10_IN pin on the   P2 connector of the star trigger slot  Refer to Table B 4  P2  J2  Connector  Pinout for the Star Trigger Slot  You must manually switch SW1 on the  chassis backplane to enable or disable routing an external clock to  peripheral slots     NI PXI 1031 PXI 1031DC User Manual 1 8 ni com          Installation and Configuration    This chapter describes how to install  configure  and use the PXI 1031 and  PXI 1031DC chassis     Before connec
38. l Component Interconnect  PCI   Specification 2 1 or later for industrial and or embedded applications  requiring a more robust mechanical form factor than desktop PCI    It uses industry standard mechanical components and high performance  connector technologies to provide an optimized system intended for rugged  applications  It is electrically compatible with the PCI Specification  which  enables low cost PCI components to be utilized in a mechanical form factor  suited for rugged environments     Canadian Standards Association    A method of propagating signals along a bus  in which the devices are  prioritized on the basis of their position on the bus    Direct current    Declaration of Conformity    Ratio of output power to input power  expressed as a percentage    Electronic Industries Association    NI PXI 1031 PXI 1031DC User Manual G 2 ni com    embedded system  controller    EMC    EMI    F  FCC    filler panel    G    GPIB     amp rms              IEEE        National Instruments Corporation G 3    Glossary    A module configured for installation in slot 1 of a PXI chassis  This device  is unique in the PXI system in that it performs the system controller  functions  including clock sourcing and arbitration for data transfers across  the backplane  Installing such a device into any other slot can damage the  device  the PXI backplane  or both     Electromagnetic Compatibility    Electromagnetic Interference    Federal Communications Commission    A blank module fr
39. libration Certificate   If your product supports calibration   you can obtain the calibration certificate for your product at  ni com calibration     If you searched ni   com and could not find the answers you need  contact  your local office or NI corporate headquarters  Phone numbers for our  worldwide offices are listed at the front of this manual  You also can visit  the Worldwide Offices section of ni  com niglobal to access the branch  office Web sites  which provide up to date contact information  support  phone numbers  email addresses  and current events     NI PXI 1031 PXI 1031DC User Manual C 2 ni com    Glossary                                                    Symbol Prefix Value               10 12  n nano 10     u micro 10 6     milli 10 3  k kilo 103  M mega 106  G giga 10    T tera 102   Symbols     Degrees    IV                         ANSI    AUTO    AWG    Equal or greater than  Equal or less than  Percent    Ohms    Amperes   Alternating current   American National Standards Institute  Automatic fan speed control    American Wire Gauge       National Instruments Corporation G 1    NI PXI 1031 PXI 1031DC User Manual    Glossary    backplane    cfm  CFR  cm    CompactPCI    CSA    D    daisy chain    DC    DoC    E    efficiency    EIA    An assembly  typically a printed circuit board  with connectors and signal  paths that bus the connector pins    Celsius   Cubic feet per minute   Code of Federal Regulations  Centimeters    An adaptation of the Periphera
40. ng it in a mild soap solution and then  vacuuming or blowing air through it  Rinse the filter with water and allow  it to dry before reinstalling it on the chassis     You can replace the fan filter with part number 150139 C from Air  Filtration Products  Inc   Tucson  AZ 85705  if necessary        National Instruments Corporation 3 3 NI PXI 1031 PXI 1031DC User Manual       Specifications    UN Caution If the PXI 1031 PXI 1031DC chassis is used in a manner inconsistent with the    instructions or specifications listed by National Instruments  the protective features of the  chassis may be impaired         Note Specifications are subject to change without notice     This appendix contains specifications for the PXI 1031 and PXI 1031DC  chassis            1031 Chassis       Electrical  AC Input  Input voltage                     2 2        100 240 VAC  Operating voltage                                     90 264 VAC  Input frequency                      eese 50 60 Hz  Operating frequency range                      47   63 Hz  Input current rating                    eese 4 2 A  Over current                                                5 A fuse in power supply     no user serviceable components  inside chassis        1 The operating range is guaranteed by design        National Instruments Corporation A 1 NI PXI 1031 PXI 1031DC User Manual    Appendix A Specifications    Eff Cien Y 4e iei ete ena  gt 65  at full load  normal input  voltage  Power                               
41. ni   com info and enter    the info code   eedback        2004 National Instruments Corporation  All rights reserved     Important Information       Warranty    The NI PXI 1031 and NI PXI 1031DC are warranted against defects in materials and workmanship for a period of one year from the date of  shipment  as evidenced by receipts or other documentation  National Instruments will  at its option  repair or replace equipment that proves to  be defective during the warranty period  This warranty includes parts and labor     The media on which you receive National Instruments software are warranted not to fail to execute programming instructions  due to defects  in materials and workmanship  for a period of 90 days from date of shipment  as evidenced by receipts or other documentation  National  Instruments will  at its option  repair or replace software media that do not execute programming instructions if National Instruments receives  notice of such defects during the warranty period  National Instruments does not warrant that the operation of the software shall be  uninterrupted or error free     A Return Material Authorization  RMA  number must be obtained from the factory and clearly marked on the outside of the package before  any equipment will be accepted for warranty work  National Instruments will pay the shipping costs of returning to the owner parts which are  covered by warranty     National Instruments believes that the information in this document is accurate  The 
42. ni com       Getting Started    This chapter describes the key features of the NI PXI 1031 and  PXI 1031DC chassis  and lists the kit contents and optional equipment  you can order from National Instruments     Unpacking       Carefully inspect the shipping container and the chassis for damage  Check  for visible damage to the metal work  Check to make sure all handles   hardware  and switches are undamaged  Inspect the inner chassis for any  possible damage  debris  or detached components  If damage appears to  have been caused during shipment  file a claim with the carrier  Retain the  packing material for possible inspection and or reshipment     What You Need to Get Started           Q                D DO UO LU        National Instruments Corporation    NI PXI 1031 or NI PXI 1031DC chassis  Filler panels    Power cable  either            power cable   tefer to Table 1 1 for AC power cables      DC power cable    NI PXI 1031 PXI 1031DC User Manual  Read Me First  Safety and Radio Frequency Interference  Driver CD ROM containing NI PXI chassis software    Chassis number labels    1 1 NI PXI 1031 PXI 1031DC User Manual    Chapter 1 Getting Started    Table 1 1  AC Power Cables       Power Cable    Reference Standards                            Standard 120 V  USA  NEMA 5 15   Switzerland 220 V SEV   Australia 240 V AS C112   Universal Euro 230 V CEE  7   II  IV  VII IEC83  North America 240 V NEMA 6 15   United Kingdom 230 V BS 1363 IEC83          If you are missing any of t
43. oes not boot  refer to your controller user manual     2 7 NI PXI 1031 PXI 1031DC User Manual    Installation and Configuration    Chapter 2    Figure 2 4 shows a PXI controller installed in the system controller slot of  a PXI 1031 PXI 1031DC chassis  You can place CompactPCI or PXI    modules in any other slot                                      3 NI PXI Controller    Injector Ejector Rail     1031DC 2    PXI 1031 PXI    Chassis    1          NI PXI Controller Installed in a PXI 1031 PXI 1031DC Chassis    4    Figure 2    PXI Modules    Installing       Complete the following steps to install a module     1     Make sure the power switch is in the Off  Standby  position     Install a module into a chassis slot by first placing the module card    edges into the front module guides  top and bottom   as shown in    2     Figure 2 5  Slide the module to the rear of the chassis  making sure that  the injector ejector handle is pushed down as shown in Figure 2 3     handle to fully inject the module into the chassis frame  Secure the  module front panel to the chassis using the module front panel    When you begin to feel resistance  push up on the injector ejector  mounting screws     3     ni com    2 8    NI PXI 1031 PXI 1031DC User Manual    Installation and Configuration    Chapter 2                0   0000   E   0000000                        500000000000 0004  00000000 000  00900 0009 JU                    A                      5 NI PXI Controller    Injector Ejector Han
44. ont panel used to fill empty slots in the chassis     1  grams   2  a measure of acceleration approximately equal to 9 8 m s   General Purpose Interface Bus  IEEE 488     A measure of random vibration  the root mean square of acceleration levels  in a random vibration test profile    Hours    Hertz  cycles per second    International Electrotechnical Commission  an organization that sets  international electrical and electronics standards    Institute of Electrical and Electronics Engineers    Mainframe peak current    NI PXI 1031 PXI 1031DC User Manual    Glossary    in     inhibit    jitter    kg    L  Ib    load regulation    MAX    MHz    NEMA    NI    Inches    To turn off    A measure of the small  rapid variations in clock transition times from their  nominal regular intervals  Units  seconds RMS     Kilograms    Kilometers    Pounds    The maximum steady state percentage that a DC voltage output will  change as a result of a step change from no load to full load output current    Meters    NI Measurement  amp  Automation Explorer  the utility that allows you to  configure and test your PXI system    Megahertz  One million Hertz  one Hertz equals one cycle per second        Millisecond  one thousandth of a second  10 3     National Electrical Manufacturers Association    National Instruments    NI PXI 1031 PXI 1031DC User Manual G 4 ni com    NI DAQmx    NI VISA    ns    ppm  PXI    PXI_CLK10    R    RMS    5    S  skew    slot blocker    ST    standby        National 
45. ooting wizards  thousands of example  programs  tutorials  application notes  instrument drivers  and  so on         Free Technical Support   All registered users receive free Basic  Service  which includes access to hundreds of Application  Engineers worldwide in the NI Developer Exchange at  ni com exchange  National Instruments Application Engineers  make sure every question receives an answer     For information about other technical support options in your  area  visit ni  com  services or contact your local office at  ni com contact     Training and Certification    Visit ni com training for  self paced training  eLearning virtual classrooms  interactive CDs   and Certification program information  You also can register for  instructor led  hands on courses at locations around the world     System Integration   If you have time constraints  limited in house  technical resources  or other project challenges  National Instruments  Alliance Partner members can help  To learn more  call your local  NI office or visit ni com alliance     Declaration of Conformity  DoC    A DoC is our claim of  compliance with the Council of the European Communities using  the manufacturer s declaration of conformity  This system affords  the user protection for electronic compatibility  EMC  and product  safety  You can obtain the DoC for your product by visiting  ni com certification     C 1 NI PXI 1031 PXI 1031DC User Manual    Appendix C Technical Support and Professional Services    e Ca
46. ral module in this slot     The star trigger slot can also be used to provide a PXI_CLK10 signal to  the backplane  For more information regarding PXI_CLK10  refer to the  System Reference Clock section     Peripheral Slots    There are three peripheral slots  including the star trigger slot     Local Bus    The PXI backplane local bus is a daisy chained bus that connects each  peripheral slot with adjacent peripheral slots to the left and right  refer to  Figure 1 5   For example  the right local bus of slot 2 connects to the left  local bus of slot 3  and so on     The left local bus signal lines on slot 2 are used for star trigger and do not  connect to slot 1  The right local bus signal lines on slot 4 are not routed  anywhere     Each local bus is 13 lines wide and can pass analog signals up to  42 V between cards or provide a high speed TTL side band digital  communication path that does not reduce the PXI bus bandwidth     Initialization software uses the configuration information specific to  adjacent peripheral modules to evaluate local bus compatibility        National Instruments Corporation 1 7 NI PXI 1031 PXI 1031DC User Manual    Chapter 1 Getting Started       Star Triggers                   co  ai   a    System Controller Slot  1   Star Trigger Peripheral Slot  2     Local Local  Bus Bus             Peripheral Slot  3   Peripheral Slot  4                                            PCI Arbitration and Clock Signals          Figure 1 5  PXI Star Trigger and Loca
47. rs or a toothed lug     Connecting to Power Source           Cautions      not install modules prior to performing the following power on test     To completely remove power  you must disconnect the AC power cable  and DC power   if applicable      If both AC and DC power cables are connected  the chassis will draw power from both  sources        PXI 1031 PXI 1031DC User Manual 2 4 ni com    Chapter 2 Installation and Configuration    Connecting to an AC Power Source    Attach input power through the rear AC inlet using the appropriate   AC power cable supplied  Refer to Figure 1 2  Rear View of the PXI 1031  Chassis  or to Figure 1 3  Rear View of the PXI 1031DC Chassis  to locate  the AC inlet     The power switch allows you to power on the chassis or place it in standby  mode  Press the power switch to the On position  if not already on    Observe that all fans become operational     Connecting to a DC Power Source  PXI 1031DC Only     Table 2 1  DC Power Requirements                   Electrical Element Requirement  Voltage 11 30 VDC  Max  DC Input Current 30 amps             For full chassis power  the DC source must be capable of providing  a minimum of 300 watts of continuous power per feed pair to the  P1 connector on the PXI 1031DC power supply     DC Connector    Figure 2 2 shows the DC connector  P1  that appears on the rear panel of  the PXI 1031DC power supply        Positive Negative                Figure 2 2  The P1 DC Input Connector        National Instrument
48. s  1 7  star trigger  ST  slot  1 7  system reference clock  1 8  trigger bus  1 8  fan speed  setting  2 3  front view  figure   1 3  installation  See installation   configuration  and operation  key features  1 2        National Instruments Corporation F3    Index    maintenance  See maintenance of  PXI 1031  module cooling air intake  figure   2 3  optional equipment  1 5  rack mount kits  1 5  rack mounting  2 4  rear view of chassis  1 4  safety ground  connecting  2 4  PXI 1031DC  backplane  interoperability with  CompactPCI  1 6  local bus  1 7  overview  1 6  peripheral slots  1 7  star trigger  ST  slot  1 7  system reference clock  1 8  trigger bus  1 8  fan speed  setting  2 3  installation  See installation   configuration  and operation  key features  1 2  maintenance  See maintenance of  PXI 1031DC  module cooling air intake  figure   2 3  optional equipment  1 5  rack mount kits  1 5  rack mounting  2 4  rear view of chassis  1 4  safety ground  connecting  2 4    R    rack mount kit dimensions  figure   A 13  rack mount kits  1 5   rack mounting  2 4   related documentation  viii    NI PXI 1031 PXI 1031DC User Manual    Index    5    safety  and caution notices  2 1  ground  connecting  2 4  specifications  table   A 8  service interval  3 1  setting fan speed  2 3  software  NI resources   C 1  specifications  backplane  A 9  dimensions  figure   A 11  A 12  electromagnetic compatibility  A 9  mechanical  A 10  rack mount kit dimensions  figure   A 13  safet
49. s Corporation 2 5 NI PXI 1031 PXI 1031DC User Manual    Chapter 2 Installation and Configuration    To build a custom DC cable  be sure to note the positive     and negative        terminals shown in Figure 2 2  Use the following components or their  equivalents to mate to the P1 port        Positronic connector  part number CBD7W2F0000      Positronic hood  part number D15000GEO   e Two Positronic contacts  part number FS4008D  choice of solder cup  or crimp terminals       Use of UL listed AWG  10 wire is recommended   maximum length  216 in      Install an F30A 500 VDC 600 VAC  1 5 in  x  41 in   10 mm x 38 mm   Midget fast acting fuse on the positive     wire of the custom cable as close  to the power source as practical            Ferraz Shawmut FEB 81 81 fuse holder  with  Ferraz Shawmut FSB1 insulating boots  and an ATM30 fuse  1s recommended     Refer to the N  PXI 1031DC DC Cable Kit Installation Guide for  information on fuse installation          Note You        purchase an optional DC cable from National Instruments that incorporates  an in line fuse and the mating connector for the P1 port     Installing a        Controller       This section contains general instructions for installing a PXI controller  in the chassis  Refer to your PXI controller user manual for specific  instructions and cautions  Complete the following steps to install a  controller     1  Connect the AC or DC power source to the PXI chassis before  installing the controller  The AC power cor
50. tation for  information on cleaning individual CompactPCI or PXI modules     Use a dry  low velocity stream of air to clean the interior of the chassis   Use a soft bristle brush for cleaning around components     UN Cautions Avoid getting moisture inside the chassis during exterior cleaning  especially  through the top vents  Use just enough moisture to dampen the cloth     Do not wash the front  or rear panel connectors or switches  Cover these components while  cleaning the chassis     Do not use harsh chemical cleaning agents  they may damage the chassis  Avoid chemicals  that contain benzene  toluene  xylene  acetone  or similar solvents     Clean the exterior surfaces of the chassis with a dry lint free cloth or a   soft bristle brush  If any dirt remains  wipe with a cloth moistened in a mild  soap solution  Remove any soap residue by wiping with a cloth moistened  with clear water  Do not use abrasive compounds on any part of the chassis     Cleaning and Replacing the Fan Filter       A dirty fan filter can dramatically reduce the cooling performance of the  chassis  Clean the filter whenever it becomes visibly dirty  You can easily  remove the chassis air filter from the bottom of the chassis by removing the  filter cover  To remove the filter cover  loosen the retainer screw  The filter  cover is shown in Figure 1 4  Bottom View of PXI 1031 PXI 1031DC  Chassis     NI PXI 1031 PXI 1031DC User Manual 3 2 ni com    Chapter 3 Maintenance    Clean the fan filter by washi
51. the same specifications apply to V I O  and  5 V     NI PXI 1031 PXI 1031DC User Manual A 10 ni com    Appendix A Specifications    Figure    1 and Figure A 2 show the PXI 1031 PXI 1031DC dimensions   The holes shown are for the installation of the optional rack mount kits as  shown in Figure A 3  Notice that the front and rear rack mounting holes   size M4  are symmetrical         4   10 12  257 1      gt                                       e 9     o o  e  e      e  o o  e e  o e     e e e       dum E         8 69  220 8   gt                  Figure A 1  PXI 1031 PXI 1031DC Dimensions  Front and Side  in Inches  mm         National Instruments Corporation A 11 NI PXI 1031 PXI 1031DC User Manual    Specifications                                                                                                                                                        659   16 74     4                        8 816  223 93   gt   lt   n      d      2A A           4   3              6 578   167 08              NI PXI 1031 PXI 1031DC User Manual    Figure A 2  PXI 1031 PXI 1031DC Dimensions  Bottom  in Inches  mm     A 12    ni com    Specifications    Appendix A    Figure A 3 shows the PXI 1031 PXI 1031DC rack mount kit components                                            2 Rack Mount Kit    PXI 1031 PXI 1031DC Chassis    1          PXI 1031 PXI 1031DC Rack Mount Kit Components    3    A    Figure    NI PXI 1031 PXI 1031DC User Manual    4 13        National Instruments Corporation
52. ting the chassis to a power source  read this chapter and the    Read Me First  Safety        Radio Frequency Interference document  included with your chassis     Safety Information       UN Caution Before undertaking any troubleshooting  maintenance  or exploratory procedure   carefully read the following caution notices     This equipment contains voltage hazardous to human life and safety  and is  capable of inflicting personal injury     e Chassis Grounding    The chassis requires a connection from the  premise wire safety ground to the chassis ground  The earth safety  ground must be connected during use of this equipment to minimize  shock hazards  Refer to the Connecting Safety Ground section for  instructions on connecting safety ground       Live Circuits   Operating personnel and service personnel must not  remove protective covers when operating or servicing the chassis   Adjustments and service to internal components must be undertaken  by qualified service technicians  During service of this product   the mains connector to the premise wiring must be disconnected   Dangerous voltages may be present under certain conditions   use extreme caution     e Explosive Atmosphere    Do not operate the chassis in conditions  where flammable gases are present  Under such conditions  this  equipment is unsafe and may ignite the gases or gas fumes         National Instruments Corporation 2 1 NI PXI 1031 PXI 1031DC User Manual    Chapter 2 Installation and Configuration    e 
53. to 50   C  Tested in accordance  with IEC 60068 2 1 and  IEC 60068 2 2     Relative humidity range                           10 to 90   noncondensing   Tested in accordance with  IEC 60068 2 56     Storage Environment   Ambient temperature range                        20 to 70   C  Tested in  accordance with IEC 60068 2 1  and IEC 60068 2 2     Relative humidity range                           5 to 9596  noncondensing   Tested in accordance with  IEC 60068 2 56     Shock and Vibration    Operational shock                                    30 g peak  half sine  11 ms pulse   Tested in accordance with  IEC 60068 2 27  Test profile  developed in accordance with  MIL PRF 28800F          National Instruments Corporation A 7 NI PXI 1031 PXI 1031DC User Manual    Appendix A Specifications    Random Vibration   Operating                   ceri oe 5 to 500 Hz  0 3 Sims                                  2  42222  5 to 500     2 4      Tested in accordance with  IEC 60068 2 64  Nonoperating  test profile exceeds the    requirements of  MIL PRF 28800F  Class 3      Acoustic Emissions    Sound Pressure Level  at Operator Position    Tested in accordance with ISO 7779      PXI 1031DC  Auto fan  at 25   C ambient               45 5 dBA  High fan           49 4 dBA    Sound Power   Tested in accordance with ISO 7779      PXI 1031DC  Auto fan  at 25   C ambient               54 3 dBA  High faites  2n 58 2 dBA    Common Specifications       Safety    The PXI 1031 PXI 1031DC chassis was evaluat
54. utlet apertures along the right  side  the top  and the back of the chassis have adequate ventilation  Provide  at least 44 5 mm  1 75 in   clearance above  behind  and on the sides of the  unit for adequate venting  High power applications may require additional  clearance     NI PXI 1031 PXI 1031DC User Manual 2 2 ni com    Chapter 2 Installation and Configuration                                                         CN 2                            A                          OJ                  e                                                 Te       49 e        1 Air Outlets 2 Air Intake       Figure 2 1  PXI 1031 PXI 1031DC Module Cooling Airflow Side View    Install the chassis so that you can easily access the bottom panel  This  simplifies replacing the air filters  if necessary     Setting Fan Speed    The AUTO HIGH fan speed selector switch is on the rear panel of the  PXI 1031 and PXI 1031DC  Refer to Figure 1 2  Rear View of the  PXI 1031 Chassis  or Figure 1 3  Rear View of the PXI 1031DC Chassis   to locate the fan speed selector switch  Select HIGH for maximum cooling  performance  recommended  or AUTO for quieter operation  The fan  speed is determined by chassis intake air temperature when set to AUTO     Installing Filler Panels    To improve module cooling performance  install filler panels  provided  with the chassis  in unused or empty slots  Secure with the captive  mounting screws provided         National Instruments Corporation 2 3 NI PXI 1031 PXI 
55. y  A 8  specifications  PXI 1031  acoustic emissions  A 4  sound power  A 4  sound pressure level  at operator  position   A 4  chassis cooling  A 2  electrical  AC input     1  DC output  A 2  environmental  A 3  specifications  PXI 1031DC  acoustic emissions     8  sound power  A 8  sound pressure level  at operator  position   A 8  chassis cooling  A 6  electrical  AC input  A 4  DC input  A 5  DC output  A 5  environmental  A 7    NI PXI 1031 PXI 1031DC User Manual l 4    star trigger  ST  slot  description  1 7  P1  J1  connector pinouts  table   B 4  P2  J2  connector pinouts  table   B 5  star trigger and local bus routing   figure   1 8  support  technical  C 1  system controller slot  description  1 6  P1  J1  connector pinouts  table   B 2  P2  J2  connector pinouts  table   B 3  system reference clock  1 8    T    technical support  C 1  testing power up  2 4  DC  2 5  training and certification  NI resources   C 1  trigger bus  1 8  troubleshooting  NI resources   C 1    U   unpacking  PXI 1031  1 1  PXI 1031DC  1 1    W    Web resources  C 1    ni com    
    