1. 1 MANUAL Note SYNC PULSE automation When this option is selected the system will prompt for an entry to be made for the frequency that is to be detected This input range is from 48 to 75Hz If for example this was set to 72Hz for 6 2 presentation then when the system receives a synchronization signal above 71Hz the system automatically begins to rotate the PFD and moves the FHA to the 3D position Equally when the synchronization signal drops below 71Hz the system automatically stops PFD rotation and moves the FHA to the 2D position masteriimage co SD MASTERIMAGE 3D Inc 34 User Manual MI CLARITY3D SA 8 7 Setting PFD Home Position IMPORTANT PFD Home Position adjustmentis required at installation after PFD 1 replacement or Factory Default reset It is necessary to teach the system the 3D synchronization position for the PFD I 12 48 54 1 To setPFD home position from the standby condition press and hold the MENU key 6 AUTOMATION A Press the UP or DOWN key to select PFD HOME menu in the r FFD HOME SETUP screen 6 30 PHASE PFD HOME SET set MARK Top and Push RUH CANCEL NO 3 Press the ENTER key to set PFD home position 4 As instructed rotate the PFD manually so that the black sensor mark on the outer edge can be seen at the top position of the PFD window in the PFD cover as shown in this illustration PFD HOME SET Setting
2. 4 Press the UP or DOWN key to move the FHA position up or down D POSITION The FHA goes up or down quickly while pressing the UP or OLD 0374 aides NEW Er The NEW value shows current position of the FHA CANCEL SAVE 5 Press LEFT or RIGHT key to select CANCEL OK or NEW value 6 Press and hold the ENTER key on selecting CANCEL to return to the SETUP screen without saving new 2D position 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 31 User Manual MI CLARITY3D SA AD POSITION value OLD 0374 7 Press and hold the ENTER key on selecting OK to return to NEU 0415 the SETUP screen after saving new 2D position value CANCEL i 8 4 1 Moving FHA to a Predetermined 2D Position 1 To move the FHA to a predetermined 2D position from the Standby condition press and hold the 2D button MI CLARITY3D Jee 2D POSITION 21 28 50 S The display shows its status as 2D POSITION while moving MI sailen the FHA to a predetermined 2D position 2D POSITION 2 Press 3D or RUN STOP button to immediately stop the FHA motion 12 33 53 8 5 Selecting a Sync Source Note The Factory Default setting is GPIO 1 To selecta 3D synchronization input port that is to be used from the standby condition press and hold the MENU key 4 21 POSITION A d P d C SYNC SOURCE 2 Press UP or DOWN key to select SYNC SOURCE menu in 6 AUTOMATION the SETUP screen 3 Press ENTER key to select a sync sour
3. PFD RUN command been 24V max 5 EINE DINO E duca BECH ose 20 21 22 Ground 28 29 30 31 PRJ COM nDOWN mp Je m PFD DOWN command LM2901H Ss feo ee PRJ STS nLOCK gt Im PFD driving status Open High pulse 200ms collector 5 JI po output PRJ STS nUP mm J gt io PFD position status 24V 20mA nz ago Man pulse rm PR STS nDOWN mn Io In PFD position status ES en Shield ground frame frame Chassis Ground Connection aa See timing diagram for GPIO Automation next page 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 72 lt un el Mm gt E ce lt l L D un NVYOVIO ONINIL NOILVNOLNYV Old UMOp Sun OA NMOQU SIS fd lt gt NMOGU WOD ftd SUOOC lt UOJEZUOIUIUAS WOW SLS fed NNYU WOD ud lt P lt P ears SUOOZ dn ZUON gt dNU SIS Did dnu WOD Yd lt gt SWQO0Z lt 73 MASTERIMAGE 3D Inc ABSOLUTELY 3D mastermage User Manual MI CLARITY3D SA fi Ise Recelver Max 25V ST3232ECTR Table B 2 TTL Automation come J s eow S ocom J 7 woconen Frit teveisywe mee RS 232 Level SYNC input 5 13232ECTR Max 25V Chassis Ground Connection x gt No connection RS 232 Driver ina A No connection 2 Ground Inverting receiver RS 485 422 Max 25V Driver Non inverting receiver ST485BD 7 Max 25V E Inverting t
4. 7 Once all entries have been made press the Save button Lastly itis necessary to program the control macros in the server 8 Press the Edit Control Cues button and the following screen will display masterlimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 87 User Manual MI CLARITY3D SA Kee eer We Me Me EE id ESE ES ES EES EMESIS elle a Ea ES a ie EIERE A ES BO e Less el KS 10 Press the Enter button and enter the command value for the event Again in this case START 6 masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 88 User Manual MI CLARITY3D SA NOM EI RS ES LR ER ER EN ER ER eee 10 14 ER EE BR EC el fees Ga U ele 11 Press the Enter button to save this change then go back and make entries for the remaining four macros that are required Event Name STOP Enter Value STOP Event Name 2D POSITION Enter Value PFD DOWN Event Name 3D POSITION Enter Value PFD UP Event Name UP DOWN STOP Enter Value PFD STOP Once all macros have been created return to the Actions tab of the Automation screen to create the events that are needed to communicate This is done by pressing the Add button 12 For each event choose the device that was defined in the first step Masterlmage and then select the required event action from the dropdown list for example Start 13 Follow the same steps to create the rest of the event actions for Stop 3D Position 2D Position and Up Down Stop L masterimage
5. initials PC These will include PC OK and AR PC Any PFDs without a PC CAUTION Use only Polarizing Filter Disks PFD with a colored label including the label must be changed immediately due to risk of possible material failure wa Note If turning the PFD to suit the system installation conditions please follow steps 1 4 and 8 14 of this section 1 Disconnect the MI CLARITY 3D power cord and sync cable and move them out from in front of the projector in order to have good access and lighting to work on the filter head assembly 2 Carefully remove the PFD cover by removing the eight screws Remove the screws in a sequence starting with bottom screws and moving on to top screws masterIimage ABBOLUTELY 3D MASTERIMAGE 3D Inc 46 User Manual MI CLARITY3D SA 3 Unfasten the PFD by removing the twelve outer screws holding it in place followed by the center PFD position guide and screw PFD Position Guide PFD Position Guide Screw PFD Outer Screws and Washers CAUTION Use ONLY a hand screwdriver to loosen and tighten the PFD screws DO NOT use any powered screwdriver or drill motor that could over tighten the screws and damage the PFD 6 masteriimage ABBOLUTELY 3D MASTERIMAGE 3D Inc 47 User Manual MI CLARITY3D SA Carefully remove the PFD from the drive hub 5 Setthe old PFD aside and immediately mark it with a permanent marker as follows
6. SET SERVO the SETUP screen 7 Press and hold the ENTER key on selecting RD to read data en MS of the defined address from Servo Pack 8 Press and hold the ENTER key on selecting WR to write data EXIT RD UR of the defined address into Servo Pack 8 14 System Log Information Note The system can store up to 2048 unique operation logs referenced by date and time These can assist with system troubleshooting should a problem occur 14 35 02 1 To get system information from the standby condition press the MENU key more than 1 second 13 SET SERVO a d 14 LOG INFO Acta or DOWN key to select LOG INFO menu in the 15 INFORMATION an N Press ENTER key to get and see log data masteriimage co SD MASTERIMAGE 3D Inc 43 User Manual MI CLARITY3D SA LOG INFO The display shows the index of recent log time stamp log name parameter 1 and parameter 2 29 49 4 Press UP or DOWN key to change the log INDEX EXIT The Index is simply the sequential number of each log data entry Log Data entries are date time stamped the second line in the display The message is displayed on the third line The maximum number of stored log messages is 9999 5 Press LEFT or RIGHT key to select INDEX or EXIT 6 Press and hold the ENTER key on selecting EXIT to return to the SETUP screen Current Log Messages Log name Description 1 Parameter 2 Parameter Remarks STE Rotating PFD after
7. 128 sectors 256 sectors Upgrade or Verify Action File File Vendor ID Transtered data size O KE 0 Bytes of 0 KB 0 Bytes Targets in file Time duration 00 00 00 6 Select new firmware file from the location it was saved on your computer having the dfu file extension in the Open dialog box Then click the Open button to upgrade firmware lt Open Look in Desktop Name M Eco A mi_sp_v0 9_dfu_hex 20110901 A MISPMonitor_v0 7 6 22 setup _20110901a 1 New folder 3 mi_sp_v0 8 1_20110909 dfu rn mi_sp_v0 8 1_20110909 dfu IR File name Fles of type C Open as read only 7 Click the Upgrade button to start firmware upgrading 6 masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 62 User Manual MI CLARITY3D SA lt DfuSe Demo v3 0 0 Available DFU and compatible HID Devices eee ae ca n SC Vendor ID Vendor ID Supports Upload _ Manifestation tolerant Z Supports Download _ Accelerated Upload ST Procuct ID 7 Can Detach Enter DFU modeHID detach Leave DFU mode Actions Select Tanget s Version Target ld Name Available Sectors Double Click for more 00 Intemal Flash 256 sectors 01 SPI Flash M25P64 128 sectors 02 NOR Flash M29W128F 256 sectors Upload Action Upgrade or Verify Action File File mi_sp_v0 8 1_20110909 dfu Vendor ID 0483 Targets in file Gees JO ST Transfe
8. BUTTON LED On while completing a task or an action BUTTON LED always On eS BUTTON LED blinking while completing a task or an action masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 55 User Manual MI CLARITY3D SA 11 2 Fuses If the system is plugged in and the MI CLARITY 3Ds LCD display on the control panel does not light up when the power breaker is switched ON and the Power button has been pressed then it is necessary to check the main power fuses To check and replace fuses 1 Turn off the main power breaker and unplug the MI CLARITY 3D 2 To check the fuses through the base access door remove the main base cover plate 3 Unlock and open access door and locate the two fuse holder modules as shown in this photo Location of 2 fuse holder modules 4 Open each fuse holder and remove the fuses as shown in the photos below masterIimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 56 User Manual MI CLARITY3D SA 5 Check the fuses for continuity Open burned fuses can be replaced with time delay fuses of either FNM 10 or FNQ R 10 type FNM 10 Type Fuse 6 Install the good fuses and any replacements and close the fuse holders and base door 7 Plug in the MI CLARITY 3D and turn on the power breaker If fuses blow again or if the fuses are OK and therefore not the problem then contact your local service provider or MASTERIMAGE Technical Support see Section 1 2 Contacting Technical Support for de
9. DATA NNNNNNNN EXIT RD WR 14 LOG INFO INDEX NNNN YYYY MM DD gt hh mm ss log_msg param1 param2 EXIT Get log data Value INNNN 0000 2048 15 INFORMATION MASETERIMAGE 3D INC DIGITAL 3D CINEMA SYSTEM gt MI CLARITY3D F W VER 000 004 002 FPGA VER 00c Sep 1 2011 05 26 31 Show system information F W Version FPGA Version Date and time of building F W masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 28 User Manual MI CLARITY3D SA 8 Detailed Setup and Configuration of the MI CLARITY3D 8 1 Setting the Clock Note The Factory Default setting is JAN 01 2011 00 00 00 1 To setthe local time and date on the system from the standby condition press and hold the MENU key 1 CLOCK 2 hihi or DOWN key to select CLOCK menu in the SETUP F LIFT ZERU Y 3 Press ENTER key to set clock 4 Press UP or DOWN key to increase or decrease the value of selected field e Press LEFT or RIGHT key to select a field for changing MONTH its value 31 011 e Press and hold the ENTER key on selecting CANCEL to eee Ee E return to the SETUP screen without saving the current CANCEL SAVE value e Press and hold the ENTER key on selecting SAVE to return to the SETUP screen after saving the current value Note To rapidly increase or decrease a value of selected field press and hold UP or DOWN key 1 To adjust the zero position of the lifting colum
10. Selected this sends IMB output directly to ICP This is required if no LD is installed 3D Control e Enable 3D Selected e 3D Sync Input Mode Use Selected Input Port polarity true e Frame Rate N M 6 2 e L R Display Sequence Left LIR1 L2R2 e 3D Sync Polarity True If left right eye images swapped set to Inverted e Dark Time 1157 e Output Delay 0 e Phase Delay 0 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 22 User Manual MI CLARITY3D SA 6 Basic Operation of the MI CLARITY3D 2 Note In order to prevent accidental operation press and hold all function buttons for more than 2 seconds for the system to respond 6 1 System Ready Standby Condition With the projector in 3D mode channel 1 Ensure thatthe AC Power Breaker switch is ON 2 Push the POWER button on the Control Panel to start the system MI CLARITY3D BEA Readiness is indicated by e POWER button LED is illuminated MNI CLARITYSD U 1 7 0 e The display shows its name and firmware version READY e The display shows its status as READY when it is ready to run 11 55 17 e The display shows the current set time masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 23 User Manual MI CLARITY3D SA 6 2 Move Up and Down the PFD 1 In order to position the PFD in front of the projector lens push the UP arrow button to move the FHA in an upwards direction or the DOWN arrow button for downwards until t
11. Used removed on today s datel 6 Wipe any dust off of the PFD cover back with a Suitable cleaning cloth but not the PFD cleaning cloth 7 Unwrap the new PFD as follows e First remove the circular protective film from the polarization filter side of the PFD e Then remove the individual pieces of cling film from each of the 12 filter segments if applicable wBipeies Note PFDs labeled with the AR PC code as shown at right do not have the small segment cling film pieces so simply remove the circle of protective film The protective film appears dull and is easily removed if the filter is shiny these pieces have already been removed 6 masterimage co SD MASTERIMAGE 3D Inc 48 User Manual MI CLARITY3D SA e Last peel off the sticky film from the clear Side of the filter 8 Orient the disk with the filter material facing the correct side for your theatre The PFD Is labeled to show This side is towards screen and This side is towards projector CAUTION The Projectionist or O perator A should inspect the surface of the PFD to check for damage using a bright light such as flash light If there is any damage on polarizing filter disk please replace it with spare PFD The polarizing filter material side of the PFD must always face the screen 9 Carefully place the PFD on the hub and assemble the PFD Position Guide LI masterimage co S
12. us Note The Barco projectors should have the field L R Input Reference set to Use line interleave First line Left second line right Barco Series Il projectors have a pre installed 3D configuration file for the settings required by the Masterlmage 3D system it is possible to select this file rather than making manual entries masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 21 User Manual MI CLARITY3D SA 5 4 2 IMB Configuration Settings Projector configuration settings when using an IMB Integrated Media Block are slightly different an example of this is given below for a Christie projector and a Doremi IMB The changes are highlighted in bold Other projector IMB manufacturers configurations may vary Slightly please contact the respective manufacturers for specific information Config 1 e Input IMB Internal e Data Format 4 4 4 RGB e Source File Based on content resolution aspect ratio 1998x1080 Flat 2048x858 Scope etc e Screen File Site Specific typically Flat or Scope based on content e Use PCF notselected unchecked e Lamp File Site Specific e ILS File Site Specific e Auxiliary Lens Site Specific Selected if Anamorphic Lens or WCL needed otherwise unselected Config 2 e Measured Color Site Specific Create on site e Target Color DC28 DCI XYZE 314 351 e Colour Space Unity RGB e Gamma Gamma 2 6 e LUT CLUT Linear 9x9x9 e Scan Type Progressive e LD Bypass
13. 10 Turn off the MI CLARITY3D AC Power Breaker and then turn it on again cycle the power 11 Press the MI CLARITY 3D POWER button and check the new version number on the System Version screen as shown below MI CLARITY3D U 1 2 0 11 55 17 12 3 Upgrade FPGA Binary 1 Connect between the MI CLARITY3D and your PC using a USB A to B cable 2 Check the STMicroelectroncis Virtual COM Port number in the Device Manager of your PC See Appendix E page 93 3 Execute Monitor program by double clicking the program s icon in your PC MI CLARIT LI masteriimage co SD MASTERIMAGE 3D Inc 64 User Manual MI CLARITY3D SA 4 Click the Setup button to open the Setup Dialog window 5 Select the COM Port number of STMicroelectonices Virtual COM Port that you checked in step 2 and click OK Example Setup Dialog 6 Click the Connect button to connect between the Monitor program and the MI CLARITY 3D File Information File Path D Project MI2100R _Releas 20111201 MI 2100R_R26 dat Filesize 129693 bytes Packet Size 256 bytes Download O bytes 129693 bytes Ready Cu Jam e Example FPGA Download Dialog masterimage MASTERIMAGE 3D Inc 65 ABSOLUTELY 3D User Manual MI CLARITY3D SA 8 Click the Open button to open the Open dialog 9 Select new FPGA binary file having dat file extension in the list of Open dialog box and c
14. COM port driver following the on screen instructions to complete the process 2 Execute the DfuSe Demo executable file downloaded from the ftp site to install the DfuSe Demo utility program following the on screen instructions to complete the process 12 2 Upgrade Firmware of MI CLARITY3D 1 Connect between the MI CLARITY3D and your PC using a USB cable 2 Push and hold the MI CLARITY3D POWER button to turn off the system power 3 Push and hold the ENTER key and push the POWER button to change the system to the DFU Device Firmware Upgrade mode The screen shown below will display on the MI CLARITY 3D VER 000 000 002 Jun 24 BOL 17 47 40 4 Execute DfuSe Demo utility by double clicking the kesa icon on your PC desktop 5 Click the Choose button to open the pre downloaded firmware file masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 61 User Manual MI CLARITY3D SA lt a DfuSe Demo v3 0 0 Available DFU and compatible HID Devices DFU Mode SIM Device in DELL Mode Application Mode Vendor ID 0483 Supports Upload Manifestation tolerant Supports Download Can Detach Enter DFU mode HID detach Leave DFU mode Actions Select Tanget s Target ld Name 00 Intemal Flash m SPI Flash M25P64 02 NOR Flash M29W128F Upload Action Accelerated Upload ST Procuct ID Vendor ID Poad ID DF11 Version Version 0200 1200 Available Sectors Double Click for more
15. Inc 16 User Manual MI CLARITY3D SA Note This switch can only be used when the system is in READY status When the Up arrow switch is pressed and held the up motion of the filter head assembly continues to move until the switch is released Use extreme caution in adjusting the filter head height for the first time The control panel may be on either side of the projector based on user access and closest positioning of the filter to the lens Result When in position the MI CLARITY3D Filter Head Assembly FHA should be parallel to the projector lens from both the top and side views Make sure all motor mount screws and nuts are tight 5 3 1 Fine adjusting the Image Position on the MI CLARITY3D PFD CAUTION Do not make position adjustments while the PFD is turning the stationary PFD to the image for more than 30 seconds ata time Note To prevent burning the filter use a darker image for this setup and do not expose The PFD cover should be approximately to inch away from the projector lens when viewed from the side 1 Project an image onto the screen see Note above 2 Pushing the Up or Down arrow button briefly fine adjust the position of the image on the MI CLARITY3D PFD so that it is centered just below the top edge of the PFD area and equally spaced on the left and right sides The image below illustrates how the projected image should be positioned on the MI CLARITY 3D PFD masterimage AB
16. USB E mulation M onitoring Log Message Download Program Upgrade Input amp Automation Ethernet Automation LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 11 User Manual MI CLARITY3D SA 5 Installation and Configuration 5 1 Unpacking the MI CLARITY3D 1 Inspectthe MI CLARITY3D crate for any external damage 2 Carefully remove the crate fasteners and top and sides of crate using an 8mm socket and power tools 3 Loosen the shipping straps and remove the protective wrap 4 Ensure all items are included MI CLARITY 3D cover installation kit box and spare polarizing filter disk Replacement PFD masterImage Power Cable USB Cable amp Cleaning Cloths GPIO Sync Cable Sample 3D Glasses MI CLARITY 3D Installation Kit Box LI mastermage ABSOLUTELY 3D MASTERIMAGE 3D Inc 12 User Manual MI CLARITY3D SA 5 1 1 Unpacking and preparing the MI CLARITY3D rolling wheels The unit is shipped with the rolling wheels locked After unpacking turn the orange rings in the wheel assembly to the left clockwise in order to raise the locking pads and allow the unit to be rolled easily MI CLARITY 3D Rolling Wheel 5 2 Orienting the MI CLARITY3D in front of the Digital Projector There are four ways the filter head and main base can be oriented in order to best fit the Space of the projection booth and projector am Note For all orientations described below t
17. and unplug the MI CLARITY 3D 3 Loosen and remove the four hex head bolts attaching the motor mount to the support bracket while supporting the weight of the filter head assembly Use hex key to remove bolts 4 Remove the FHA 5 Turn around the head assembly through 180 taking care not to stress the control cables Place the mounting bracket on the rubber pad and reattach the motor mount with the four hex head bolts 6 Confirm that the PFD faces the correct direction when positioned in front of the lens polarizing filter material to the screen side of the filter disk Change the PFD direction if necessary IMPORTANT PFD Home Position adjustment is required Refer to section 8 7 Q Setting the PFD Home Position on page 35 masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 70 User Manual MI CLARITY3D SA 7 Move system in front of projector Make various adjustments to PFD position according to standard installation procedures by moving the motor up and down see 5 3 on page 16 and moving the bracket in its slide in order to position the filter close to the lens at the correct height see Orienting the MI CLARITY 3D in front of the Digital Projector on page 13 LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 71 User Manual MI CLARITY3D SA 15 Appendix B MI CLARITY3D Automation Table B 1 GPIO Automation DSUBA GPIO DSUB37 e _ ea Re TT fee PRJ COM nRUN 2 fe r
18. lt Method gt lt StreamDevice gt The symbols amp x0D amp x0A are necessary at the end of each command to close the command in the xml structure Finally the automationcues xml file can be edited so that the MI CLARITY 3D device is associated with the command names that have been created This allows the cues to be seen in the Qube graphical interface wa Note Again this file is a shared file with other devices in the system so must be edited and not replaced 4 Edit this file so that it contains the information below lt Cue name Start 3D gt lt Actions gt lt InvokeMethod name S tart device Masterlmage gt lt Actions gt lt Cue gt lt Cue name Stop 3D gt lt Actions gt lt InvokeMethod name Stop device Masterlmage gt lt Actions gt lt Cue gt lt Cue name 3D Position gt lt Actions gt lt InvokeMethod name 3D position device Masterlmage gt lt Actions gt lt Cue gt lt Cue name 2D Position gt lt Actions gt lt InvokeMethod name 2Dposition device Masterlmage gt lt Actions gt lt Cue gt 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 83 User Manual MI CLARITY3D SA lt Cue name Up Down Stop gt lt Actions gt lt InvokeMethod name PF DStop device Masterlmage gt lt Actions gt lt Cue gt Once this file has been edited and saved the graphical interface of the Qube server will display the new cues that can be selected for future
19. playlist creation Status control shows schedule ingest keys media logs setup 2D j2k ch 48 16 e 3D Position Start 30 BH ma an show duration 00 00 00 TEOT i ave BO cancel 15 1 3 GDC Server The steps described below are specific to the GDC SX 2001 server If information is required for different models please contact GDC directly 1 Inthe SMS Main Menu press the Control Panel button and log on as Maintenance Access LI masteriimage dial i MASTERIMAGE 3D Inc 64 jez los i O i ii TSE E EF a a 13 03 32 GDC SMS sta ried 13 03 39 Show is loaded les 13 03 39 Unfinished playback resumed Stopped 1 8 Show test Clip DATE NIGHT_TLR B_F_EN XX_US GB_51_2K_TCF_20090930_FKI 2 Once you have logged on press the Automation button found on the General tab masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc masteriimage ABSOLUTELY 3D brume The MI CLARITY3D must be added as a device within the GDC server configuration 3 Select the Devices tab and press the Add button The following screen will display MASTERIMAGE 3D Inc 86 4 Name the new device Masterlmage and ensure the Type selection is set to NETWORKSOCKET then press OK 5 In the next screen enter the configuration settings for the MI CLARITY 3D IP Address and Port Number 6 In the Transport option select TCP and in the Linefeed Type select CR and ensure the Status is set to Enabled
20. please refer directly to Section 8 of this manual Follow steps 8 1 to 8 7 for the minimum requirements for the setup of the MI CLARITY 3D to ensure Safe installation and optimum performance from this model IMPORTANT PFD Home Position adjustment is required at installation 1 Refer to section 8 7 Setting the PFD Home Position on page 35 Should you be unsure about any particular step please read this manual in its entirety before contacting Technical Support for assistance LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 9 User Manual MI CLARITY3D SA 4 System Overview 4 1 Key Product Components Filter Head Assembly amp Polarization Filter Disk PFD Up Down Lifting Column System Control Panel I O Ports for Synchronization amp Automation Lockable W heels AC Power Breaker Cabinet Lock AC Power Inlet masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 10 User Manual MI CLARITY3D SA 4 2 Control Panel Run Stop Button 3D Button to move the PFD to the pre programmed 3D position Emergency Stop Button The display shows Firmware Version Current Operating State and Time MI CLARITY3D ci ES 2D Button to move the PFD to the pre programmed 2D position Setup Keys Menu Left Up Down E nter R ight 4 3 UO Ports GPIO Sync Input amp Automation 3D Port Sync TTL Sync Input RS 232C Sync Input
21. ABSOLUTELY 3D MASTERIMAGE 3D Inc 89 User Manual MI CLARITY3D SA LI masterImage ABSOLUTELY 3D MASTERIMAGE 3D Inc 90 User Manual MI CLARITY3D SA 16 Appendix C Installation Record The form below and on the next page is an example of the installation record form to be filled out once the MI CLARITY 3D has been set up and configured For a copy of the form to be filled out please contact your equipment provider or email a request to support masterimage3d com Once the form is completed send it to support masterimage3d com or fax a copy to 1 323 960 8008 Masterlmage 30 System Installation Record 2 Systom infomation masterIimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 91 User Manual MI CLARITY3D SA 17 Appendix D Periodic Maintenance The table below show the least regular maintenance points carried out by operator in cinema To guarantee reliable system operation weekly monthly and yearly routine maintenance actions should be conducted like manual description or other technical bulletin that MASTERIMAGE released If you need any assistance regarding these routine jobs please contact your equipment provider or email support masterimage3d com INTERVAL ITEM ACTION Refer to Cleaning the Wi O PFD Cleaning Remove dust from PFD PFD page 52 eekly O Check for PFD Damage SS Burns scratches etc O Clean inside of PFD Cover Clean inside PFD cover D Monthly Che
22. CANCEL SAVE Seta 2D position of PFD Value 0000 lt 1800 Default N A OxFFFF SYNC SOURCE ESRI INTERNAL Hz 23D PORT OLD mmm 3 RS 232C NEW MMM ATUL CANCEL SAVE 5 INTERNAL 6 E XIT Select a 3D synchronization input port Value GPIO 3D PORT RS 232C TTL INTERNAL EXIT Default GPIO INTERNAL Sync Value 48 75Hz Default 48Hz masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 25 User Manual MI CLARITY3D SA CES geg ee eg Ce AUTOMATION MANUAL REFERENCE Hz GPIO OLD mmm RS 232C NEW MMM RS 422 CANCEL SAVE 3D PORT ETHERNET SYNC PULSE EXIT Selecta 3D automation I O port Value MANUAL GPIO RS 232C RS 422 3D PORT ETHERNET SYNC PULSE Default MANUAL REFERENCE Hz Value 48 75Hz Default 72Hz PFD HOME Set MARK Top Setting PFD PFD Home Setting and Push RUN Home Position Completed CANCEL Wait a second EXIT Set the PFD Home position to teach the system the 3D synchronization position for the PFD during the initial installation after PFD replacement or Factory Default reset 3D PHASE 1 SYNCPOLARITY 7 SYNC POLARITY 2 0FFSET OLD TRUE 3 EXIT NEW INVERT CANCEL SAVE 2 OFFSET OLD mmm NEW MMM CANCEL SAVE Adjust sync polarity and the offset of 3D phase if any 3D artifacts are seen on screen SYNC POLARITY Value TRUE INVERT Default TRUE OFFSET Value 180 180 Default 000 9 DIAGNOSTICS Diagnose FSMC TEST
23. D MASTERIMAGE 3D Inc 49 User Manual MI CLARITY3D SA 10 To secure the PFD do the following e Insert the countersunk PFD Position Guide Screw Do not tighten at this time e Insert each of the 12 PFD Outer Screws but do not tighten Ensure flat and spring washers are fitted to each screw CAUTION Whenever fitting the PFD on the 3D system a flat washer and a spring lock washer must be used on the 12 outer screws to fix it securely and safely e After all the screws are in place begin tightening each screw one ata time following the pattern indicated below e Tighten only hand tight Do not use a powered screwdriver DO NOT force to avoid damage to the PFD Work once around the PDF to check that all screws have been tightened e fa suitable torque measuring tool is available apply a maximum torque to the PFD Position Guide Screw of 13 kgf cm or 11 3 Ibf in 0 94 Ibf ft and 12 kgf cm or 10 4 Ibf in 0 868 Ibf ft to the 12 PFD Outer Screws LI masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 50 User Manual MI CLARITY3D SA 11 Replace the PFD cover by carefully placing it over the PFD Replace all eight screws loosely Hand tighten the screws firmly from the top to the bottom 12 Plug in the power cable turn on the system power and push the Run Stop switch to check the filter turning balance After a successful check stop the filter power off the system and unplug the power cable 13 Mo
24. FT or RIGHT key to select CANCEL SAVE or NEW value Press and hold ENTER key on selecting CANCEL to return to the SETUP screen without saving new 3D phase value Press and hold ENTER key on selecting SAVE to return to the SETUP screen after saving new 3D phase value 8 9 System Diagnostics SETUP TUP 12 58 13 8 3D PHASE A ERIC 10 SET PASSUORDY masterlmage ABSOLUTELY 3D To diagnose the system from the standby condition press and hold the MENU key Press UP or DOWN key to select DIAGNOSTICS menu in the SETUP screen Press ENTER key to diagnose the system MASTERIMAGE 3D Inc User Manual MI CLARITY3D SA 4 Press LEFT or RIGHT key to select CANCEL or OK 5 Press and hold the ENTER key on selecting CANCEL to re ICS return to the SETUP screen without diagnosing the system Systen Status 6 odia the ENTER key on selecting OK to start CANCEL ES After diagnosing the system the display shows the system status as shown at left D IAGHOSTICS e FSMC TEST shows the test result of communication to ES TEST Ok FPGA SUD TEST Ok EXIT e EEP TEST shows the test result of EEPROM e SVO TEST shows the test result of communication to Servo Pack D IAGNOSTICS If a test has failed the display shows its status as NG Not Good BAHE JEU ah 7 Press ENTER key to return to the SETUP screen SVO TEST HG 8 10 Setting the Menu Password Note The defau
25. INGS THEINFORMATION COKTA HEC TOLERANT ES APPLY AS SHOWN BELOW INTHS CR amp ANGIS CONACENTAL ANG FROPHETARY AHD RENAJ HS Ve M ser ol THE EXCLUS VE PROPERTY OF MASTE IMAGE ilari THS DRAVI HG MAY HOT BE US taz E RITE SURFACE ROUGHNESS CONSENT OFIMAR CORPGRATION ACCEPTANCE OFTHIS CSM HG THE BEARER AGREES TO THESECCHOMOHS MASTERIMAGE 3D Inc User Manual MI CLARITY3D SA REVISIONS APPROVED CAD A AINTAINED DATA CHANGES SHA LL BEINCORPORATED 6 MABTERMAGE ELECTRO MI CALLY OAKVILLE THIRD ANGLE PROJECTION masterEmage ONTARIO ABSOLUTELY 3D PAT DECO GE EE Outline Drawing fin star rem ener sue PE Ami 1035 DW Tel wengs beem LJ Ami 1008 7 B vi sheer 1 OF 1 REVISIONS paw arproveD CAD MAINTAINED DATA CHANGES SHA LL BEINCORPORATED 6 MABTERMAGE ELECTRO MI CALLY OAKVILLE THIRD ANGLE PROJECTION sterEmage ONTARIO Cacca ABSOLUTELY 3D PAT DECIO se MIL Fe Outline Drawing mm a mn nr maen GP 2010 A mi 1 034 DW paren Ae T 8 sm 1 OF 7 69 User Manual MI CLARITY3D SA 14 Appendix A Turning the Filter Head Assembly FHA The following steps describe removing and turning the FHA in order to orient the system in a non standard configuration Reference Orientations 3 amp 4 Reversed Filter Head Right and Left on page 15 1 Raise the filter motor at least 8 cm from its bottom stop position or to the memorized 3D position 2 Power off
26. Installation amp Operation Manual MI CLARITY3D MI CLARITY3D SA Digital 3D Cinema System Installation amp Operation Manual Revision No 3 0 J Master mage i Ri MI CLA RITY3D ABSOLUTELY 3D User Manual MI CLARITY3D SA Revision History Release Status PD 1 2 J une 8 2012 Preliminary Document Photo replacement required J uly 19 2012 Clarity photos added warnings PD 1 3 Preliminary Document RJG updated troubleshooting improved Sept 15 2012 Updated Draft System firmware updates Sept 18 2012 Initial Release Production Release Copyright 2005 2012 MASTERIMAGE 3D INC All Rights Reserved MASTERIMAGE 3D INC Proprietary All other trademarks and copyrights are the property of their respective owners LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 2 User Manual MI CLARITY3D SA Locations MASTERIMAGE 3D INC 5358 Melrose Ave 4 Floor Hollywood CA 90038 TEL 323 606 7800 FAX 323 960 8008 MASTERIMAGE 3D ASIA LLC 22F BYC HIGHCITY B D A 371 17 Gasan dong Geumcheon gu Seoul 153 803 South Korea TEL 82 2 3438 1600 FAX 82 2 3438 1698 MASTERIMAGE 3D EUROPE PLC Pinewood Studios Pinewood Rd Iver Heath Buckinghamshire England SLO ONH TEL 44 1753 785131 Fax 44 1753 656050 URL http www MASTERIMAGE 3d com Email Contact support MASTERIMAGE3d com LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 3 User Manual MI CLARI
27. NEW PASSWORD DS KEY Bu 3 Press and hold the ENTER key on selecting any digit to fi ee e ee select 4 digit password CANCEL OK 4 Press and hold the ENTER key on selecting CANCEL to RE return to the SET PASSWORD screen without saving new NEW PASSWORD ws password KEY Ee 5 Press and hold the ENTER key on selecting OK to confirm new 4 digit password CANCEL OK Note A password must consist of 4 digits There will be no action when pressing ENTER key on selecting OK if new password has been entered with fewer than 4 digits masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 38 User Manual MI CLARITY3D SA CONFIRM PUD 9 KEY e CANCEL OK CONFIRM PWD KEY 0 Ca PE PE PE CANCEL KT Press UP or DOWN key to select a digit CANCEL or OK value Press and hold the ENTER key on selecting any digit to select 4 digit password Press and hold the ENTER key on selecting CANCEL to return to the SET PASSWORD screen without saving new password Press and hold the ENTER key on selecting OK to return to the SET PASSWORD screen after saving new 4 digit password To Protect the System with a Password If the password is turned ON you must enter the correct 4 digit password to access the SETUP Screen PASSWORD TRI KEY CANCEL OK PASSWORD KEY ie CANCEL OK PASSWORD KEY PE PE PE PE CANCEL E 6 masterimage ABSOLUTELY 3D Pr
28. NTENWIA GU DT mem _ ele BE 3 To insert an action for each newly created macro select the macro in question from the list within the Macro window and press the Insert a New Action button which will become available Send Message Send a message to a connected device Macro Editor 4 Highlight the Input Output option and Send Message and then press the Add button The following configuration window will appear 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 78 User Manual MI CLARITY3D SA Macro Editor Doremi Cinema Sa a Message e Master Device name Macro Master Image e Master Image 2D Master Image 3D rr type Master Image sa fret H Start n Automation Cue Macro Editor f Send a Mes 5 In this window choose the device Masterlmage from the Device name dropdown list and type in the Message label of Masterlmage Start Ensure the Message type is Text and type Start n in the Message box After all fields have been completed press the OK button 6 Repeat this step for the remaining four macros entering the corresponding message text Masterlmage Stop Stop n Masterlmage 2D PFD DOWN n Masterlmage 3D PFD UP n Masterlmage Up Down Stop PFD Stop n Note Atthe end of each command add the text n to complete the command 7 Once all message text has been added press the Save button from the main Macro Editor sc
29. P Universal Serial Bus controllers End of Manual For additional information go to www masterimage3d com LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 93
30. PFD Home Position Wait a second H 6 5 Press the ENTER key on selecting CANCEL to return to the SETUP screen without setting PFD home position 6 Press the RUN STOP button to set PFD home position PFD HOME SET PFD Home sett ing Press the ENTER key on selecting EXIT to return to the Completed SETUP screen after setting PFD home position NI masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 35 User Manual MI CLARITY3D SA 8 8 Adjusting 3D Phase CAUTION While itis possible to make adjustments to the 3D PHASE angle within the MI CLARITY 3D this is not usually required or recommended Note The Factory Default setting is SYNC POLARITY TRUE 3D PHASE 000 If any 3D artifacts are seen on screen It is possible to manually adjust the 3D phase of the MI CLARITY 3D 12 54 31 1 To adjust 3D phase from the standby condition press and hold the MENU key 7 PFD HOME EH SETUP screen 3 Press the ENTER key to adjust 3D phase Oo D PHASE 2 Press the UP or DOWN key to select 3D PHASE menu in the 2 DIAGNOSTICS 7 4 The default setting for this item is 0 and can be adjusted both 3D PHASE OLD 060 NEW CANCEL SAVE 3D PHASE OLD 000 NEW 005 CANCEL TU to the positive and negative in 1 steps using the UP or DOWN key It is necessary to view the image on screen after each adjustment to ensure any artifacts have been eliminated Press LE
31. Projector Sound System and Lighting Control etc For this reason the file cannot be replaced and must be modified with the lines added as above for the MI CLARITY 3D Note The automationdevices xml file is a shared file for all devices that the server can Next it is necessary to create and load onto the server the Masterlmage xml file This file defines and names the commands and text that will be sent to the MI CLARITY 3D 3 Edit this file so that it contains the information below lt xml version 1 0 encoding utf 8 gt lt StreamDevice name Masterlmage xmins http schemas qubecinema com Automation S treamDevice 2008 01 26 gt lt Method name Start gt lt Instructions gt lt Send gt S tart amp x0D amp x0A lt Send gt lt Instructions gt lt Method gt lt Method name Stop gt lt Instructions gt lt Send gt Stop amp x0D amp x0A lt Send gt lt Instructions gt lt Method gt lt Method name 3Dposition gt lt Instructions gt lt Send gt PFD UP amp x0D amp x0A lt Send gt lt Instructions gt lt Method gt lt Method name 2Dposition gt lt Instructions gt lt Send gt PFD Down amp x0D amp x0A lt Send gt 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 82 User Manual MI CLARITY3D SA lt Instructions gt lt Method gt lt Method name PF DStop gt lt Instructions gt lt Send gt PFD Stop amp x0D amp x0A lt Send gt lt Instructions gt
32. Qube server it is necessary to edit two XML files within the server s configuration The files in question are located in the path C Program Files Qube Cinema XP and are named automationdevices xml and automationcues xml Within the same path it is necessary to load a new file named Masterlmage xml 1 First create a link between the server and the MI CLARITY 3D within the automationdevices xml file Below you will see the structure of this file lt xml version 1 0 encoding utf 8 gt Devices xmins http schemas qubecinema com Automation Devices 2008 01 26 gt Device name Device Name class Device Class enable true gt lt C onfiguration gt lt Key name F ile value file name of the device gt lt Key name Address value address value gt lt Key name P ort value port value gt lt Configuration gt lt Device gt lt Devices gt 6 master mage ABSOLUTELY 3D MASTERIMAGE 3D Inc 81 User Manual MI CLARITY3D SA 2 Complete the red fields with the details of the Masterlmage MI CLARITY 3D where Device Name IS Masterlmage Device Class IS Qube Automation streamdevice TCP file name of the device IS Masterlmage xml addess value IS MI CLARITY 3D Assigned IP Address oort value IS 23 Itis recommended that Notepad or a similar program is used for xml file editing control via automation cues thus it will contain information for devices such as DLP
33. SOLUTELY 3D MASTERIMAGE 3D Inc 17 User Manual MI CLARITY3D SA 3 Once the position has been adjusted store this as the 3D Position as described in Setting a 3D Position page 30 5 3 2 Locking the MI CLARITY3Ds wheels in place Lock down all four of the base wheels by lowering the foot pads To do this turn the orange ring to the right counter clockwise This will stabilize the unit Turn the orange ring to the right to bring each footpad down and secure the MI CLARITY 3D masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 18 User Manual MI CLARITY3D SA 5 3 3 Releasing the footpads to move the MI CLARITY3D Turn the orange ring to the left clockwise to raise each footpad to release it and move the MI CLARITY 3D Turn the orange ring to the left to raise each footpad to release it and move the MI CLARITY 3D 5 4 Projector File Setup It is necessary to configure the projectors 3D control file to work with the MI CLARITY3D The procedures below describe configuring the control files for Series and Series Il projectors Follow the instructions for the appropriate projector Recommended Dark Time Reference Settings 5 4 1 Series Il Projectors Configure the projector settings as shown in the illustrations below for NEC Christie and Barco projectors Please also note the following Note In certain installations where space is restricted in front of the projector or where the lens protrude
34. Sync signal Hz Servo speed Hz This log is receivig sync signal recorded when locking sync Signal CYNC Changing sync signal Sync signal Hz Servo speed Hz Stop running PFD or change sync signal more than 3Hz SPER Servo pack Error N A N A DC3D PFD moved to 3D Preset 3D position Position counter of position counter of lifting column current lifting column DC2D PFD moved to 2D Preset 2D position Position counter of position counter of lifting column current lifting column 8 15 System Information 14 38 00 1 To get system information from the standby condition press and hold the MENU key 14 LOG INFO a 15 INFORMATION 2 Press UP or DOWN key to select INFORMATION menu in the 16 EXIT F SETUP screen 3 Press ENTER key to get system information The display shows the Copyright Product Name Brand Name F W firmware version FPGA version and date and time of building FW 4 Press ENTER key to return to the SETUP screen masterlmage FORMES MASTERIMAGE 3D Inc 44 User Manual MI CLARITY3D SA 9 Installation Checklist __ ge Determine spacing and position of the MI CLARITY 3D in front of the Projector Check that the polarizing filter is on the screen Side of the disk and silver screen and non depolarizing port glass are installed Check SYNC Cable connection between MI CLARITY 3D and Projector Check the Projector lens and MI CLARITY 3D filter are parallel and that the
35. System RUNN NO da a 24 l Menu EE wiin Default EES 25 8 Detailed Setup and Configuration of the MI CLARITY 3D 29 8 1 un lte fon 0 6 EE 29 8 2 Setting the Lifting Column Zero Position 29 Biss DEMING D POS OM EE 30 8 3 1 Moving FHA to a Predetermined 3D Position 31 8 4 SUR AD POSION EE 31 8 4 1 Moving FHA to a Predetermined 2D Position s sessssssesrssrnerrerrerrrerrerrrerrerreerrerren 32 Or DelCCUIAG OS Siani 32 8 5 1 Setting Internal Sync Source Frequency RS 33 8 6 Selecting an Automation SOS a a oc 34 8 7 Seting PED HOME POSITION ens EE 35 Bee AGUSINOELRI cai 36 5 VSEM Dagono aaa 36 8 10 Setting the Menu Password e 37 BEL EPEn TC ON I UON ee a e a 40 8 12 Performing a Factory Reset iris 42 8 13 Servo ack Parameter in tel OM a nine 43 0 14 SystemiLog INIOFMMAtONi na 43 db SNS OO aO a ei 44 2 ln Ce E lee E CRIS a ee dt 45 10 MARNI eri io 46 10 1 Changing the Polarizing Filter DISK DEDlL 46 202 CO PFD ere a ea 52 10 21 MOTOR SOUS WE 52 10 22 Cleaning G PF D rares nes niiin e E ces dates 52 Tl SABIE TIOUDIESNOOUNG gucci 55 11 1 Button LED NOUNCAUO LEE 55 KR PUSSS naro 56 11 3 Servopak Correct Status INDICA 57 11 4 Servopak Error Status MGIC ATOS ane dates ts ne 58 11 4 1 E Stop Button Pressed Rs 58 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 5 User Manual MI CLARITY3D SA NIE GAN EN ageet E 59 RS NA NOCCONNECIOO a a a 60 12 Firmware Upgrad
36. TY3D SA Table of Contents L IOO E 7 LE WEICON EE 7 LZ COMPACUNG TECARIca ISU polesine 7 2 Warnings and Cautions sirena 8 DS DID OM ES OMR a na ee ae a ee Ge on tie 8 2 2 Burning Polarization Filter Warning 8 2 3 New PFD Installation CO Le EE 8 2 4 General GEIER 8 Zio ANIMI 8 de ICI IS CO ON IS A II Re a tie 9 E Ee 10 4 1 Key Product E elle E ET 10 D CONO EAN er a a a ia 11 Se E e WE EC 11 5 Installation and Configuration 12 5 1 Unpacking the MI CLARITY3D Ness 12 5 1 1 Unpacking and preparing the MI CLARITY 3D rolling wheels 13 5 2 Orienting the MI CLARITY 3D in front of the Digital P rojector 13 5 2 1 Orientation 1 Standard Rig t sessessssrserrnsrnerrnrrnnrnnrrnnrnnrrenrnnrrnnrrerrerrerrrerrerrens 13 52 2 Orientation 2 Standard WOT EE 14 5 2 3 Orientations 3 amp 4 Reversed Filter Head Right and Left 15 53 Positioning DE ee 16 5 3 2 Locking the MI CLARITY3Ds wheels in place 18 5 3 3 Releasing the footpads to move the MI CLARITY3D 19 5 4 Projector File Genup rrt rrn rrtt trte rENPrEEOrEEErEEErEEEREEE REEE EEEt 19 Dil Senes PO COR a Ee 19 5 42 IMB Configuration SCUINGS sissnscusssdiniccnscunasentaiwsvent veaniaa detuned ccanenapaninennnepncininenias 22 6 Basic Operation of the MI CLARITY3D UN 23 6 1 System Ready Standby Condition 23 6 2 MOVE UD and DOWN erba 24 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 4 User Manual MI CLARITY3D SA 63 SE ie
37. base wheels are locked Check location of the projected image on the top center of MI CLARITY 3D filter Confirm that PFD Home Position adjustment has been performed Check the Projector 3D Control file settings Check that the LCD display is showing the sync frequency and LOCK when filter is running Check the 3D picture for proper 3D effects proper framing and no ghosting Complete the Installation Record Form and send it to support MASTERIMAGE 3d com or fax a copy to 323 960 8008 e Store the position settings for both 2D and 3D LI mastermage dial i MASTERIMAGE 3D Inc 45 User Manual MI CLARITY3D SA 10 Maintenance power cord prior to cleaning the PFD Injury may result while working near moving parts Do not power up the system to Spin the PFD while cleaning the PFD AA WARNING To avoid electric shock ensure the power switch is off and unplug the CAUTION Avoid scratching and damaging the PFD by performing the cleaning procedure and use cleaning solutions only as outlined in this document Only handle the PFD by the outer edge A CAUTION Use great care not to touch the image area on either side of the PFD 10 1 Changing the Polarizing Filter Disk PFD Polarizing Filter Disks PFD should be replaced annually to ensure proper optical performance A spare PFD should be kept on hand at all times Contact your local equipment provider or MASTERIMAGE office for the supply of new PFDs
38. ce 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 32 User Manual MI CLARITY3D SA mener SYNC SOURCE shows the current synchronization input port i a in the list The selected option is indicated by the asterisk A 4 Press the UP or DOWN key to select previous or next sync 1 GPIO E source in the list e AU PORT The options for sync source include GPIO 3D PORT RS SYNC SOURCE 232C TTL and INTERNAL C INTERNAL gt Press ENTER key to return to the SETUP screen after saving gt the current selected item as new sync source 1 GPIO e 6 Press ENTER key on Selecting EXIT to return to the SETUP screen without changing the current sync source 8 5 1 Setting Internal Sync Source Frequency Note The Factory Default setting is 48Hz If the INTERNAL sync source is selected the default frequency of the internal sync generator can be adjusted as required from 48 to 75Hz 1 Press the ENTER key on selecting INTERNAL to set the default frequency of the internal sync generator 4 TL A 5 INTERNAL gt 6 EXIT 7 The display shows the default frequency of the internal sync umana generator OLD 048 2 Press UP or DOWN key to increment or decrement the default frequency of NEW value NEW 3 Press LEFT or RIGHT key to select CANCEL OK or NEW CANCEL SAVE due rtrd ere A Press and hold the ENTER key on selecting CANCEL to ei re
39. ck all screws on the O Check screws are secure Filter Head Assembly to verify they are secure Refer to Changing the Y early O PFD Replacement Replace the PFD Polarizing Filter Disk PFD page 46 LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 92 User Manual MI CLARITY3D SA 18 Appendix E Check the STM Virtual COM Port Number You can see the virtual COM Port number after connecting MI CLARITY 3D to your PC e Run the Control Panel in your PC e Double click the Device Manager in the Control Panel screen e Select the Ports COM amp LPT item in the Device Manager screen e Check the Port Number of STMicroelectronics Virtual COM Port COMxx File Action View Help e elei lIHesleel seg gt ua Disk drives gt Be Display adapters gt DVD CD ROM drives D De Human Interface Devices p 4g IDE ATA ATAPI controllers gt AD Keyboards p D Mice and other pointing devices gt kk Monitors PO amp Network adapters Microsoft Loopback Adapter 2 mY Realtek PCle GBE Family Controller KC VirtualBox Host Only Ethernet Adapter KC VMware Virtual Ethernet Adapter for VMnetl VMware Virtual Ethernet Adapter for VMnet8 gt KR Portable Devices a IP Ports COM amp LPT IP Communications Port COM1 Li D afa D Sri D oli B to Serial Comm Port COM TP USB Serial Port CON gt D Processors gt Q Sound video and game controllers gt gt Storage controllers gt AR System devices D
40. ds as shown below Ensure the settings entered match those of the MI CLARITY 3D for IP Address and Port Number Check the Enabled box and save the entry JNior 310 Master Image MB2K ST MI2500 Pegase Audio z y N Menu _ Device man o REX The MI CLARITY 3D has now been successfully added into the server configuration LI master mage ABSOLUTELY 3D MASTERIMAGE 3D Inc 76 User Manual MI CLARITY3D SA Itis now possible to create the macro files to enable the server to control the MI CLARITY 3D The files required are Masterlmage Start Masterlmage Stop Masterlmage 2D Masterlmage 3D and Masterlmage Up Down Stop These are created in the Macro Editor option of the server menu Menu gt DTS Digital Cinema gt Macro Editor 3D FLAT 1920 3D SCOPE 1920 48FPS MODE MPEG SCOPE P3 Fause Automation Cue Trigger Cue 1 Within the Automation Cue tab press the button to start a new macro Replace the default Test_Macro text with the label for one of the MI macros for example MI Start Cancel 2 After the item has been created press OK return to the main Macro Editor screen Repeat this process for the other four required macros Masterlmage Stop Masterlmage 2D Masterlmage 3D and Masterlmage Up Down Stop masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 17 User Manual MI CLARITY3D SA Master Image 2D Master Image 3D Master Image Run Master Image Stop INSEE E
41. ess UP or DOWN key to select a digit CANCEL or OK value Press and hold the ENTER key on selecting any digit Press and hold the ENTER key on selecting CANCEL to return to the standby condition Press and hold the ENTER key on selecting OK to enter to the SETUP screen if the password Is correct MASTERIMAGE 3D Inc 39 User Manual MI CLARITY3D SA 8 11 Ethernet Configuration IP 192 168 000 101 SUBNET MASK 255 255 255 000 GATEWAY 192 168 000 001 PORT NUMBER 5000 Note Factory Default settings are The items that require configuration are IP SUBNET MASK GATEWAY and PORT 13 56 37 10 5ET PASSWORD 11 5ET ETHERNET 1 SET FACTORY 7 1 To configure Ethernet from the standby condition press and hold the MENU key 2 Press UP or DOWN key to select 11 SET ETHERNET menu in the SETUP screen 3 Press ENTER key to configure Ethernet 4 Press UP or DOWN key to select previous or next configuration item in the list D EXIT A 1 IP The options for Ethernet configuration include IP SUBNET MASK GATEWAY and PORT JSQUBNET MASK 7 5 Press the ENTER key on selecting EXIT to return to the SETUP screen To Set the IP Address 1 Press ENTER key on selecting 1 IP to change IP address J EXIT A LIP SUBNET MASK e 8 CANCEL Es CANCEL ZU The display shows the current IP address 2 Press UP or DOWN key to increment or decrement the selected val
42. first time on the PFD apply a small amount of solution to the cloth Then wipe a small area near the PFD hub out of the picture area and inspect the results carefully for any surface damage This must be tested on both sides of the PFD as they are made of different materials e Apply a small amount of alcohol to the cleaning cloth Never put cleaning solutions directly on the PFD Gently rub the cloth over the PFD while applying a light pressure Check the results frequently A CAUTION Projectionist or O perator should inspect the surface of PFD to detect any damage using bright light such as flash light If there is any damage on polarizing filter disk please replace it with spare PFD Note If not using the MI CLARITY 3D for several days protect the PFD with a clean cover For any other cleaning questions contact MASTERIMAGE 3D directly at support masterimage3d com LI masterimage co SD MASTERIMAGE 3D Inc 54 User Manual MI CLARITY3D SA 11 Simple Troubleshooting 11 1 Button LED Notification The system buttons contain LEDs that display system status 1 yellow LED on RUN STOP button 2 blue LED on 3D button blue LED on 2D button and green LED on POWER button BUTTONLED 0 LED ee ee STOP RUN STOP On while booting 1 Booting POWER On while system running tet e sit S top Flashes at intervals of 0 2 gt S ervopack seconds pa CG Flashes at intervals of 0 8 seconds
43. g the 2D button in order to provide access to the front and back of the filter 1 Turn off the power switch and unplug the power cord 2 Being careful to only touch the center hub spin the wheel slowly until the black sensor mark IS at the top of the PFD opening This is the starting reference point LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 52 User Manual MI CLARITY3D SA 3 Hold the PFD steady with one hand and while applying gentle pressure carefully wipe the PFD with the cleaning cloth Wipe from the center of the PFD to the outer edge only See the illustration below Black sensor mark Cleaning the PFD surface 4 Rotate the PFD slightly with the other hand between each upward wipe of the cloth Refold the cloth after every 2 or 3 wipes in order to maintain a clean cloth surface on the PFD 5 Continue to rotate and wipe the PFD until one side of the filter is clean Use the black sensor mark to indicate when the entire PFD has been wiped 6 Switch hands or sides and repeat the process for the other side of the PFD as shown in the illustration below 7 Repeat the cleaning process if required in order to completely remove any dirt or residue on the PFD Clean the other side masterIimage ABSOLUTELY 3D MASTERIMAGE 3D Inc SE User Manual MI CLARITY3D SA For areas that are difficult to clean Isopropyl alcohol is the recommended cleaning solution If using any other solution for the
44. he PFD is aligned with the projector lens e The display shows its status as UP MOVING while pressing the UP button 081 4 e The display shows its status as DOWN MOVING while eresie pressing the DOWN button 6 3 Startthe System Running 1 Press and hold the RUN STOP button for more than 3 seconds The 3D system will start IMmediately e The display shows the sync frequency as received from the MI CL amp RITYAD projector or the predefined internal frequency U 1 7 0 wv Afterthe PFD rotation has become synchronized with the input signal from the projector the display shows its status as RUNNING LUCK RUNNING LOCK along with the input frequency 2 0 HZ 12 37 41 e This indicates that the system is in sync with the projected 3D images 6 masteriimage dial i MASTERIMAGE 3D Inc 24 User Manual MI CLARITY3D SA 7 Menu Structure with Default Conditions D MES REGER REES RSC 1 MMM DD YYYY EOD sss CANCEL SAVE Set the local date and time Date J AN 01 2011 DEC 31 2050 Default J AN 01 2011 00 00 00 LIFT ZERO Adjust Lifting Adjusting Column Position Lifting Column CANCEL OK Wait a second Adjust the zero position of lifting column for eliminating accumulated position error of lifting column 3D POSITION OLD mmmm NEW MMMM CANCEL SAVE Seta 3D position of PFD Value 0000 lt 1800 Default N A OxFFFF 2D POSITION OLD mmmm NEW MMMM
45. he Polarizing Filter Disk PFD filter surface must face the screen Some setups may require that the PFD be removed and turned around in order for the material surface to face the screen 5 2 1 Orientation 1 Standard Right The system is shipped ready to be used in Standard Right orientation with the control panel facing the right side of the projector By using the adjustment slots in the filter motor mount plate the PDF can be moved laterally by up to 2 inches for fine adjustment of position relative to the projector lens This configuration is the most commonly used setup for all projector types The images below illustrate the standard right orientation as well as a standard right orientation that has been adjusted extended toward the projector masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 13 User Manual MI CLARITY3D SA Projection Projection Lens Lens Max 2 extension Standard Right Orientation Standard Right Orientation Extended 5 2 2 Orientation 2 Standard Left With overhanging lenses as commonly found in Christie projectors the system may be set with the control panel facing the left side of the projector in order to be more convenient to the operator or to deal with floor space Issues See Appendix A Turning the Filter Head page 70 for complete instructions on removing and turning the filter disk See the image below for an illustration of this orientation Note For this set
46. he following items e LIFT ZERO This process will be automatically prompted See 8 2 Setting the Lifting Column Zero Position on page 29 e CLOCK Re enter the current date and time See 8 1 Setting the Clock on page 29 e 3D and 2D Position Re enter the required height positions for 3D and 2D See 8 3 Setting a 3D Position on page 30 and see 8 4 Setting a 2D Position on page 31 e PFD Home Position Perform the Home Position adjustment Refer to section 8 7 Setting the PFD Home Position on page 35 e Ethernet Configuration If using Ethernet automation re enter the required configuration settings See8 11 Ethernet Configuration on page 40 LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 67 User Manual MI CLARITY3D SA 13 Product Specifications Model Name 200 230V MI CLARITY3D SA 100 120V MI CLARITY 3D SA T Size and Weight Projection Height Max Min 1370 870 mm 54 6 34 3 in Width 580 mm 22 8 in Depth 296 6 mm 11 7 in Weight 52 kg 114 lbs Polarized Filter Disc PFD Up Down Speed 15 mm sec 5 8 in sec for standalone only Head Dedicated settings and control buttons for 2D 3D positions Enhanced Motor Control smooth start and stop motor ramping Automation Interface Display 128x64 Graphic LCD Controls Power Run Stop 3D 2D 4 way Menu Navigation Emergency S top Log Messages Over 200 recorded events with time stamp DCI compliant systems and non DCI professional
47. ing Process for MI CLARITY 3D Series 61 12 1 Download and Install the Upgrading Utility Tools 61 12 2 Upgrade Firmware of MI CLARITY3D UN 61 KC DOS PP OR BM ely acciai 64 KC E e tele geld et e aan ann ea 68 14 Appendix Turning the Filter Head Assembly FHAJ aa 70 15 Appendix B A e E RE E RE Die Ce TEE 72 15 1 Et Me A UO Er EE 75 bili DOMIR aa ia a E 76 15 12 OUDE NT ene sa eee te ae imite 81 joy io OCDE SONO a na ee ee a Ei 84 16 Appendix C Installation RCCOM is are nanaa ares asare ananas 91 17 Appendix D Periodic Maintenance 92 18 Appendix E Check the STM Virtual COM Port Number ll 93 LI masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 6 User Manual MI CLARITY3D SA 1 Introduction 1 1 Welcome Congratulations on choosing the finest digital projection 3D system available The MASTERIMAGE MI CLARITY 3D delivers the clearest full color images in a cost effective and studio approved single projection digital 3D system Paired with MASTERIMAGE high quality 3D eyewear the MI CLARITY 3D provides the clearest and truest color 3D picture of any single filter 3D system This user manual provides all the information required for simple installations and the operation of the MI CLARITY 3D with any DLP cinema projector and digital cinema server 1 2 Contacting Technical Support If you require technical support our contact information is listed below MASTERIMAGE 3D INC Email support
48. lick the Open button Organize New folder A am W Favorites Name ME Desktop T 20111201_MIZ100R_R26 dat ET Downloads 2 Recent Places di Daum 8882 Libraries si Documents ai Music Pictures EH Videos M Computer E Local Disk C ca Local Disk D a New Volume F x SHN_Disk H wm Removable Disk i Gia Noms File pame 20111201_ML2100R_R26 dat e FPGA Files dat hd Las Cancel Example Open Dialog 10 Click Download button to start FPGA binary upgrading FPGA UPDATE e During FPGA binary upgrade the FPGA Upgrade screen will be displayed on the control panel paces GE d MASTERIMAGE 30 30 CINEMA SYSTEM 11 Click the EXIT button after confirming FPGA binary upgrade Is successful 12 Click the Info button to check the new FPGA version number an example is shown below mastermage ABSOLUTELY 3D MI 2100R Monitor Version 2 0 0 1 Copyright C MASTERIMAGE 3D LLC 2011 All rights reserved MI 2100R Information MI 2100R Firmware version Ver 2 0 2 Ethernet version Ver 1 81 0 Servo Pack Identify SGDV 01A 28h Servo Motor Identify SGMJV 6Dh Servo Motor Capacity 750 W http www masterimage3d com LI masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 66 User Manual MI CLARITY3D SA One the upgrade process is complete the system will have completed an automatic FACTORY RESET therefore it will be necessary to reset t
49. lt password is 0000 13 02 20 1 To set password from the standby condition press and hold BAU 9 DIAGNOSTICS A me MENUS 10 SET PASSUORD 2 Press UP or DOWN key to selectSET PASSWORD menu in 11 SET ETHERNET the SETUP screen 3 Press the ENTER key to set password To Set Password On Off SET PASSUORD Io The current selected condition is indicated inside the 3 EXIT brackets 1 Press ENTER key on selecting 1 PASSWORD OFF to turn ani on password for protecting the system masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 37 User Manual MI CLARITY3D SA SET PASSUORD The display shows the current status of Password on off OLD OFF 2 Press UP or DOWN key to turn on or off password protection MEU UN 3 Press LEFT or RIGHT key to select CANCEL SAVE or NEW CANCEL Ego value i A Press and hold the ENTER key on selecting CANCEL to SET PASSWORD return to the SET PASSWORD screen without saving the new 3 EXIT on off state 5 Press and hold the ENTER on selecting SAVE to return to the SET PASSWORD screen after saving new on off state 1 FASSUORD CON _ NEU PASSWORD To Change Password Enya Gea gt 1 Press the ENTER key on selecting NEW PASSWORD to 1 PASSUORD CON enange Password NEU PASSWORD 3 EXIT Note A password must consist of 4 digits like 1234 a 2 Press UP or DOWN key to select a digit CANCEL or OK value
50. masterimage3d com Web Site www Masterimage3d com USA Tel 1 323 606 7800 UK Tel 44 1753 785131 Asia Tel 82 2 3438 1600 LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 7 User Manual MI CLARITY3D SA 2 Warnings and Cautions 2 1 Spinning Filter Safety The MI CLARITY 3D operates a high speed rotating PFD Polarizing Filter Disk Keep all hands and objects away from the system when starting up and operating 2 2 Burning Polarization Filter Warning In order to avoid burning the polarization filter material the MI CLARITY 3D PFD must be lowered or moved out of the light path during lamp adjustments In general AA the PFD should always be turning when it is in the light path of the projector 2 3 New PFD Installation Caution If installing or replacing a new PFD ensure that the protective film pieces have been removed from each of the polarizing filter segments PFD Home Position adjustment MUST be performed after PFD replacement Refer to section 8 7 Setting the PFD Home Position on page 35 2 4 General Electrical Safety Disconnect the power cord before doing service work or opening the base compartment 2 5 Anti Collision Caution masterIimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 8 User Manual MI CLARITY3D SA 3 Quick Installation Guide If you are already experienced in the unpacking installation and configuration of pervious 3D Cinema Systems from Masterlmage 3D Inc
51. mm System Status EPP TEST mm CANCEL OK SVO TEST mm EXIT masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 26 User Manual MI CLARITY3D SA REGER Peet tw ET Diagnose the system status including communication to FPGA EEPROM and 10 SET PASSWORD communication to Servo pack mm Ok or NG 1 PASSWORD OFF 7 2 NEW PASSWORD 3 EXIT SET PASSWORD OLD mmm NEW MMM CANCEL SAVE NEW PASSWORD KEY o x xX CANCEL OK 7 CONFIRM PWD KEY o CANCEL OK Turn on or off system password set new 4 digit password KEY Value 0 9 Default 0 Password Value 0000 9999 Default 0000 Current Status OFF or ON 11 SETETHERNET lLIP Ip 2 SUBNET MASK MMM NNN NNN 000 3 GATEWAY gt CANCEL SAVE 4 PORT NUMBER SUBNET MASK 5 EXIT NNN NNN NNN NNN CANCEL SAVE GATEWAY MMM NNN NNN 000 CANCEL SAVE 7 PORT NUMBER nm Im mm rm CANCEL SAVE Configure Ethernet parameters for automation Value MMM 0 233 NNN 0 255 000 0 254 IP Default 192 168 000 101 SUBNET MASK Default 255 255 255 000 GATEWAY Default 192 168 000 001 PORT NUMBER 00001 49999 Default 5000 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 21 User Manual MI CLARITY3D SA Wl feed Fi Fis Le HS 12 SET FACTORY Perform Performing a Factory Reset a Factory Reset CANCEL OK Wait a second 13 SET SERVO ADDRESS 0xMMM
52. n from the Standby condition press and hold the MENU key F 2 Press UP or DOWN key to select LIFT ZERO menu in the LIFT ZERO SETUP screen 3 30 POSITION 7 3 Press ENTER key to adjust the lifting column zero position 4 Press LEFT or RIGHT key to select CANCEL or OK LIFT ZERU SET 5 Press and hold the ENTER key on selecting CANCEL to fid just Lift ing return to the SETUP screen without adjusting the lifting ERE column zero position Commn eg A 6 P d hold the ENTER k lecting OK to adjust th Press and ho e ey on selecting o adjust the CANCEL DE lifting column zero position e While adjusting the lifting column zero position the lifting masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 29 User Manual MI CLARITY3D SA LIFT ZERU SET column goes down to bottom position then goes up some Ad just ing distance and then goes down to bottom position e After finishing adjustment of the lifting column zero position SETUP screen automatically displays Lifting Columnt Wait a second 8 3 Setting a 3D Position Note The Factory Default setting is N A 12 45 25 1 To seta 3D position of Filter Head Assembly FHA from the standby condition press and hold the MENU key IFT ZERO d P d A L 2 Press UP or DOWN key to select 3D POSITION menu in the oo POSITION SETUP screen D POSITION 3 Press ENTER key to seta 3D position of FHA 4 Press UP or DOWN key t
53. n selecting CANCEL to return to the SET ETHERNET screen without saving new Gateway address 5 Press ENTER key more than 1 second on selecting SAVE to return to the SET ETHERNET screen after saving new Gateway address masterlmage FORMES MASTERIMAGE 3D Inc 41 User Manual MI CLARITY3D SA To Set the Port Number 1 Press ENTER key on selecting PORT NUMBER to change the Port Number 3 GATEWAY A 4 PORT NUMBER The display shows the current Port Number C EXIT e 2 Press UP or DOWN key to increment or decrement each digit individually to set the desired value 3 Press LEFT or RIGHT key to select each digit CANCEL or SAVE ss d Press and hold the ENTER key on selecting CANCEL to FORT NUMBER return to the SET ETHERNET screen without saving new Port OLD 00043 Number REM 00024 5 Press and hold the ENTER key on selecting SAVE to return to the SET ETHERNET screen after saving new Port Number CANCEL i 8 12 Performing a Factory Reset This option will reset all user entered information Date Time Ethernet Configuration 2D and 3D Position 3D Phase Password etc to the factory condition 14 21 37 1 To perform a factory reset from the standby condition press 11 SET ETHERNETa and hold the MENU key 17 SET FACTORY 2 Press UP or DOWN key to select SET FACTORY menuinthe 13 SET SERVO SETUP screen 3 Press ENTER key to perform a factory reset 4 Press LEFT or RIGHT ke
54. o move the FHA position up or 3D POSITION SEN OLD 0749 The FHA goes up or down quickly while pressing UP e or DOWN key NEW Mai CANCEL SAVE The NEW value shows current position of the FHA 5 Press LEFT or RIGHT key to select CANCEL SAVE or NEW 3D POSITION value OLD 0749 6 Pres sand hold the ENTER key on selecting CANCEL to NEW 0870 return to the SETUP screen without saving new 3D position value CANCEL SAVE ES 7 Press and hold the ENTER key on selecting SAVE to return to the SETUP screen after saving new 3D position value masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 30 User Manual MI CLARITY3D SA 8 3 1 Moving FHA to a Predetermined 3D Position 1 To move the FHA to a predetermined 3D position from the standby condition press and hold the 3D button The display shows its status as 3D POSITION while moving the FHA to a predetermined 3D position MI CLARITY3D Pines 3D POSITION 21 28 18 MI CLARITY3D 2 Press 2D or RUN STOP button to immediately stop the U 170 motion of the PFD 3D POSITION 12 23 41 8 4 Setting a 2D Position Note The Factory Default setting is N A ET 12 49 22 1 To seta 2D position for the FHA from the standby condition ress and hold the MENU key 3 3D POSITION A i i 4 7D POSITION 2 Press UP or DOWN key to select 2D POSITION menu in the D S1NC SOURCE e SETUP screen 3 Press ENTER key to seta 2D position of FHA
55. ransmitter 9 Non inverting transmitter Chassis Ground Connection masteriimage co SD MASTERIMAGE 3D Inc 74 User Manual MI CLARITY3D SA Table B 4 3D Port Automation DSUB15 3D Port es ae dee a EC ce COo nom R CT lt 6 MODEP 3D Mode State AUTO2 3D Reese 7 lt TS391ILT AUTO2 3D SYNCM AUTO2_INPUT_REFP Se 3D L R Input Reference p Photocoupler AUTO2_INPUT_REFM AT Vce 35V Shield SE frame frame Chassis Ground Connection 15 1 Ethernet Automation This section covers the requirements for Ethernet automation in detail and explains the process for the writing of macros for commonly found digital cinema servers in the market you are unsure of the processes involved please contact the respective manufacturer of your equipment for further information Note Attempt these steps only if you are familiar with server configuration settings If If you require detailed information on other forms of automation control please contact Masterlmage at support masterimage3d com for details masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 15 User Manual MI CLARITY3D SA 15 1 1 Doremi Server 1 Within the server menu open Device Manager Menu gt DTS Digital Cinema gt Device Manager 2 Press the Add button and the list of devices will display Shown right 3 Select the Raw option to create Masterlmage as a known device in the server s listing 4 Complete the fiel
56. rations This projector should have the L R Input Reference field set to Use selected Input port polarity true It may also be necessary to switch the Input Frame Dominance when viewing the on screen image LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 20 User Manual MI CLARITY3D SA Christie Series Il file settings for external server playback Moem svxd2tvhzk0 LE Oj x System ok CHAISTIE Channel Setup CO Channel Name 5 3D SCOPE cer Activate conta Enable 3D 3D Test Patterns Config 2 30 Control 3D Input Control 3D Output Control 3D Sync Input Mode 3D Sync Polarity Use Line Interleave first li e True L R Display Reference Dark Time ps Use 3 D L R display referer fa 1157 Frame Rate N M Output Delay ps 6 2 0 L R Display Sequence Phase Delay deg Left LIR1 L2R2 0 Defaults eg Menu Service 4 VR 04 08 33 Note The Christie projectors should have the field 3D Sync Input Mode set to Use line interleave First line Left second line right Barco Series Il file settings for external server playback Dam Control CES Frame Rate 3D Test Pattern Multiplication 6 2 48 Hz 3D Control L R Input Reference Use line interleave where first line Left second line Right Input Frame Dominance LZR Display Reference L R Output Reference Polarity GPO 1 Dark Time Adjustement Setting 1157 us Actual 1157 us Output Reference Delay Time
57. red data size 0 KB 0 Bytes of 0 KB 0 Bytes Version 0000 C Verify after download C Optimize Upgrade duration Remove some FFs Time duration een File correctly loaded Abo 8 Click the Yes button if the utility shows a confirmation dialog such as the example below after making sure the correct file has been selected for upgrade DfuSeDemo Les Your device was plugged in DFU mode So it is impossible to make sure this file is correct for this device Continue however 9 Click Quit after confirming the firmware upgrade was successful LI masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 63 User Manual MI CLARITY3D SA lt DfuSe Demo v3 0 0 Available DFU and compatible HID Devices Application Mode DFU Mode Vendor ID Vendor ID Supports Upload Manitestation tolerant Supports Download Accelerated Upload ST Procuct ID Procuct ID Can Detach Version Version Enter DFU mode HID detach Leave DFU mode Actions Select Target s Target ld Name Available Sectors Double Click for more Upload Action Upgrade or Verify Action File File mi_sp_v0 8 1_20110909 dfu Vendor ID 0483 Targets in file z 00 St Upload Procuct ID 0000 Transtered data size Version 0000 114 KB 117576 Bytes of 114 KB 117576 Bytes Verify after download Optimize Upgrade duration Remove some FFs 00 00 24 Upgrade Very Target 00 Upgrade successful Abort Time duration
58. reen 8 Now when you return to the CineLister screen and press the Refresh button the macros will all display in the Automation Cues section Shown below and can be added to future playlists as required LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 79 User Manual MI CLARITY3D SA Doremi Logo Flat_2D Doremi Logo Scope 2D New Doremi Logo_2K_3D New Doremi Logo_Flat_3D New Doremi Logo Scope 20 amp automation cues Ma Ma 27_DRESSES TRL_C_EN_XX_ E_ 20071015 SE Alvin_Trl_D_F_20071102_DDE Doremi Animated Logo i oo AMEE In future versions of Doremi software updates the Masterlmage macros will be included in a file named Masterlmage_cueslib This will remove the requirement for the information to be entered manually as described in the above steps jnior expansion module jnior Masterlmage_cueslib Certainty Manage Certainty products Moru Lane E na REES The Masterlmage_cueslib file will be found in the Library section of the Macro Editor and the macros will be seen within that file 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 80 User Manual MI CLARITY3D SA Macro Editor Doremi Cinema 0X E Reset a Save x Quit Library sons baal ae Macr Master Image 2D Mast Master Image Up Down stop Automation Cue Trigger Cue Macro Editor 15 1 2 Qube Server To create automation macros for the MI CLARITY 3D in the
59. rted 11 4 2 CN1 Not Connected SERVO ERROR Ru The display will also show an error HARUR CODE Usb similar to that shown at left If this Ip Uc H He H Bal Please check Seruo situation is seen power off the system Pack Resolve Frblem check the connection of the CN1 cable Turn the AC Power Off reinsert if necessary and power on the and turn Power Up system masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 59 User Manual MI CLARITY3D SA 11 4 3 CN2 Not Connected The display will also show an error similar to that in the image above If this Situation is seen power off the system check the connection of the CN2 cable reinsert as necessary and power on the system masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 60 User Manual MI CLARITY3D SA 12 Firmware Upgrading Process for MI CLARITY3D Series vm Note The latest firmware and associated utility tools can be downloaded from the Masterlmage FTP site ftp masterimage3d us L mi3dguestl P MI3DuploadASIA The current system firmware version can be seen on the LCD display when the system Is in Standby 12 1 Download and Install the Upgrading Utility Tools Download the firmware upgrading utility and virtual COM port driver from the following URL gt htto www st com internet mcu product 164495 jsp 1 Execute the VCP Driver executable file downloaded from the ftp site to install the virtual
60. s a long way it may be necessary to install the MI CLARITY 3D the opposite way around that is with the PFD motor under the lens 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 19 User Manual MI CLARITY3D SA In this condition it is important that the PFD itself is refitted the opposite way maintaining the polarizing material facing the screen See Orienting the MI CLARITY 3D in front of the Digital Projector page 13 Should the above installation condition be necessary then the 3D setting for L R Output Reference Polarity or 3D Sync Polarity should be changed to Inverted Always make sure that 3D material is viewed on screen to ensure no artifacts are present S Note Ifyou plan to change any of the settings shown below first contact MASTERIMAGE technical support for details see Section 1 2 Contacting Technical Support NEC Series II file settings for external server playback oma EE 3D File Name E nu Frame Rate Ratio N M Er 3D Control L R Input Reference Use Line Interleave 1st line Left 2nd line Riqht Input Frame Dominance Left L1R1 L2R2 D L R Display Reference Not Used DI L R Output Reference Polarity True D Dark Time Adjustment Setting 1157 us Actual 1 157 us Output Reference Delay Time 0 us Phase 0 deg Save Exit Settings for NEC where the projector Firmware Release Pack is lower than v2 33 are different from both Christie and Barco file configu
61. systems Maximum recommended size 60 feet 18 2 meters Silver screen is required LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 68 Center of Picture Height Min 34 3 Max 54 6 Base Depth 11 7 Width 22 8 Height 19 Filter Wheel Assembly Depth 2 4 Overall Height Filter Cover Down Approx 37 1 Weight 114 Ibs S2K g Center of Picture Height Min 672 Max 1367 Base Depth 297 Width 580 Height 483 Filter Wheel Assembly Depth 64 Overall Height Filter Cover Down Approx 942 Weight 52Kg 114 Ibs masterimage ABSOLUTELY 3D ECO DESCRIPTION Dimensions in inches UNLESS OTHERWISE SPECIFIED musl UNIT OF MEASURE INTERPRET DM ENSIGHS ANC KOLERA KEES MILUMETRES Ei PERASME W E 1554 ALL CAM ENSIOHS SHOWN APPLY AFTER PROPRIETARY PLATINGS AND COAT NGS THEINFORMATION CONTAINED TOLERANCES APPLY AS SHOWH BELO PR an EM CO TAIMED AND FROFMETARY AND RENAJ HS a aan THE EXCLUS VE PROPERTY OF MASTERIAIAGE RAMA WG ALAY HOT BE LIS ED AHGULAR DIANE HSHCHS EPROCUCECIN WHOL ORIN PART toaz HOR REVEALED TOOTH ERS YATHQUT THE PRIORA MITEH SURFACE ROUGHNISS COMSENTCFIMAX CORPCRATION ACC EPTANCE DE THIS DRAWING eee aa THE BEARER AGREES TO THESE E S i SEN EcO DESCRIPTION Dimensions in millimeters UNLESS OTHERWISE SPECIFIED wus UNIT OF MEASURE INTERPRET D EHSIQS AMD TOLERANCES MLUMETRES DX PERASME a EA ALL CAN ENSIOHS SHOWN APPLY AFTER PROPRIETARY PLATINGS AND COAT
62. tails 11 3 Servopak Correct Status Indication The Servopak inside the MI CLARITY3D has a 7 segment LED display that indicates different Status conditions for the system Both correct running conditions and error status indications are described below The images below indicate the correct status indication from the Servopak for both Standby and Running conditions masterlmage ABSOLUTELY 3D MASTERIMAGE 3D Inc 57 User Manual MI CLARITY3D SA SERVOPACK 7 YASKAWA E YASKAWA a ALII e ME deri n Bey SGDV 2R8FO1A Ka SGDV 2R8FO1A System Standby Indication System Running Indication 11 4 Servopak Error Status Indication The images below indicate particular Servopak error conditions and the respective corrective action that should be taken 11 4 1 E Stop Button Pressed Tee YASKAWA SE SERVOPACK f YASKA D YASKAWA EX o SBS SGDV 2R8F01A SGDV 2R8F01A Indication shown for 1 second Indication after 1 second until as soon as E Stop Is pressed E Stop is released rarely seen masterimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 58 User Manual MI CLARITY3D SA The display will show the E Stop indication along with the Run Stop 3D amp 2D buttons all flashing To recover from this condition check the Operating situation is safe release the E d RES Stop button by twisting in the direct of the arrows until the button pops out the system Be e can now be sta
63. turn to the SETUP screen without saving new default frequency value NEW Ore 5 Press and hold the ENTER key on selecting OK to return to CANCEL EE the SETUP screen after saving new default frequency value masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 33 User Manual MI CLARITY3D SA 8 6 Selecting an Automation Source Note The Factory Default setting is Manual Options are available to automate the control of the MI CLARITY 3D for both 2D and 3D movie presentation As a default all controls are set to be operated from the Control Panel on the system as shown below EAUX 1 Ea de from the standby condition 2 Press UP or DOWN key to S AUTOMATION menu in the gt PFD HOME el SETUP screen ni A Press ENTER key to select an automation source AUTOMATION shows the current automation source in the list AUTOMATION The selected option is indicated by the asterisk 5 3D PORT A 4 Press the UP or DOWN key to select previous or next automation source in the list 7 SYNC PULSE The options for automation source include MANUAL GPIO l RS 232C or RS 422 3D PORT ETHERNET and SYNC PULSE AUTOMATION 5 Press the ENTER key to return to the SETUP screen after dach PULSE saving the current selected item as new automation source 6 Press the ENTER key on selecting EXIT to return to the SETUP screen without changing the current automation source
64. ue 3 Press LEFT or RIGHT key to select any IP address CANCEL or SAVE 4 Press and hold the ENTER key on selecting CANCEL to return to the SET ETHERNET screen without saving new IP address 5 Press and hold the ENTER key on selecting SAVE to return to the SET ETHERNET screen after saving new IP address masterlmage FORMES MASTERIMAGE 3D Inc 40 User Manual MI CLARITY3D SA To Set the Subnet Mask 1 Press ENTER key on selecting SUBNET MASK to change Subnet Mask address 1 IF amp SUBNET MASK 3 GATEWAT SUBNET Mask The display shows the current Subnet Mask address 2 Press UP or DOWN key to increment or decrement the Fe 255 255 00 selected value 3 Press LEFT or RIGHT key to select any Subnet Mask address CANCEL or SAVE 4 Press and hold the ENTER key on selecting CANCEL to return to the SET ETHERNET screen without saving new Subnet Mask address 5 Press and hold the ENTER key on selecting SAVE to return to the SET ETHERNET screen after saving new Subnet Mask address To Set the Gateway 1 Press ENTER key on Selecting 3 GATEWAY to change Gat dd 2 SUBNET MASK A 3 GATEWAY _4 PORT NUMBER GATEWAY The display shows the current Gateway address 2 Press UP or DOWN key to increment or decrement the 197 168 070 001 selected value 3 Press LEFT or RIGHT key to select any Gateway address 4 Press ENTER key more than 1 second o
65. up the Polarizing Filter Disk PFD must be removed and turned in order for the filter surface to face the screen IMPORTANT PFD Home Position adjustment is required at installation Refer to section 8 7 Setting the PFD Home Position on page 35 masteriimage co SD MASTERIMAGE 3D Inc 14 User Manual MI CLARITY3D SA Projection Lens Base Plate Max 2 extension Standard Left Orientation 5 2 3 Orientations 3 amp 4 Reversed Filter Head Right and Left In rare cases where the lens projector floor space or port window do not allow for Standard positioning of the filter head the filter head can be removed and reversed in order to work in the unique spacing requirements and to get the filter disk as close to the lens as required 1 4 to 1 2 inch See images below for examples of this orientation If it is necessary to reverse the filter head assembly see Appendix A Turning the Filter Head page 70 for specific instructions 1 Note As in the standard setups the PFD filter surface MUST face the screen masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 15 User Manual MI CLARITY3D SA Projection Projection Lens Lens 5 3 Positioning the MI CLARITY3D 1 Position the MI CLARITY 3D centered with the projector lens and adjust the PFD height using Up arrow switch on the control panel a em Adjustable height LI masterlmage ABSOLUTELY 3D MASTERIMAGE 3D
66. ve the MI CLARITY 3D back into proper position in front of the projector lens and check that the polarization filter side of the PFD is facing the screen 14 Plug in the power cable reconnect the sync cable and check that the system is functioning properly with 3D content on the screen CAUTION PFD Home Position adjustment MUST be performed after PFD replacement Refer to section 8 7 Setting the PFD Home Position on page 35 15 Record the date of the filter change and any comments in the Service Data Records 6 masteriimage ABSOLUTELY 3D MASTERIMAGE 3D Inc 51 User Manual MI CLARITY3D SA 10 2 Cleaning the PFD 10 2 1 Materials Required To ensure that PFD is cleaned safely use materials as specified e Use only approved micro fiber type polishing cloths These cloths feel extra soft to the touch with absolutely no abrasive texture Samples are shown in the image below Gate i AR be MS ING e Isopropyl alcohol minimum 70 e Clean film handling gloves optional CAUTION The use of unapproved chemicals can lead to PFD failure Please contact MASTERIMAGE with any questions regarding cleaning materials 10 2 2 Cleaning the PFD wa Note The PFD cover does not have to be removed to clean the PDF If possible unlock the wheels and move the MI CLARITY 3Daway from the projector lens to an area with bright lighting If the unit cannot be moved out to an open space lower the FHA below the lens usin
67. y to select CANCEL or OK Perforn 5 Press and hold the ENTER key on selecting CANCEL to a Factory Reset return to the SETUP screen without performing a factory rest CANCEL DR 6 Press and hold the ENTER key on selecting OK to start to perform a factory reset SET FACTORY Wait a short time Wait a second masteriimage co SD MASTERIMAGE 3D Inc 42 User Manual MI CLARITY3D SA LIFT ZERO SET Ad just Lifting 7 After completing a factory reset LIFT ZERO SET screen Column Position shows automatically Press OK to accept this automatic CANCEL OR setting x Note For eliminating accumulated position error of lifting column adjust lifting column zero position after performing a factory reset Then the PFD Home Position adjustment MUST be performed again Refer to section 8 7 Setting the PFD Home Position on page 35 8 13 Servo Pack Parameter Information SETUP 14 25 47 1 Togetorsetparameters of Servo Pack from the standby condition press and hold the MENU key A SET FACTORY A 2 Press UP or DOWN key to select SET SERVO menu in the 3 5EI SERVO SETUP screen Ti LUG INFO 3 Press ENTER key to set parameters of Servo Pack SET SERVO 4 Press UP or DOWN key to change values of ADDRESS or DATA Hee ee Press LEFT or RIGHT key to select ADDRESS DATA EXIT RD or WR EXIT RD WH 6 Press and hold the ENTER key on selecting EXIT to return to

Download Pdf Manuals

image

Related Search

Related Contents

Greenes Fence RC 4C4 Instructions / Assembly  download  LE MONTAGE SONORE  Manual del usuario  PO BOX 582 Teutopolis, IL 62467 TEL  TOA Electronics U720 Modem User Manual  An automated assistant for organizing electronic documents  USER MANUAL MANUAL DE INSTRUCCIONES NOTICE D  ECOstyle - Van nature bewust  Bedienungsanleitung Photometer 5010  