User Manual - Home Blood Pressure Monitors
Contents
1. 06 19 2009 12 30 30 FFA 06 19 2009 12 30 30 FFA SYSTEM MENL ty SYSTEM SETUP ENTER SYSTEM TIME ENTER DELETE DATA ENTER ALARM SETUP ENTER EXIT UP ENTER DOWN When the USER PURVIEW is set to be ALL current user can be switched under main interface when set to a certain user it will not be able to switch Applying the Arm Cuff The measurement can be carried out by applying the cuff on left or right arm Remove tight fitting clothing from your upper arms Carry out the operation in a room with comfortable temperature When measuring take the thick clothes off instead of rolling up the sleeves In order to measure accurately pay attention to applying the cuff properly left arm 1 Make sure the air plug is securely inserted in the main unit 3 Arm penetrate throught the cuff the air tube of the cuff will pass the top of your palm 4 Apply the cuff to your upper arm The color marker is on the inside center of your arm and make the air tube aligned with your middle forger a The bottom of the cuff should be approximately 2cm 3cm above your elbow BP Measurement Accurate Measurement Way Measurement in quiet and relaxing state 1 Place your arm on a table 2 The cuff is level with your heart 3 The palm of the hand is up and the body relax Try to measure your blood pressure at the same time each day with the same arm and the same pose for consistenc
2. Advanced Blood Pressure and SpO2 User Manus contee 06A SOUTHEASTERN MEDICAL SUPPLY INC User Manual Blood Pressure Monitor Model CONTECOSA mTo assure the correct use of the product safety measures please carefully read user manual before using m After reading please validly keeping to refer and consult at any moment Contents Sareo e O A ET l A O O E E clas cmes 3 Button FPUNCHONS i ss revi trad i ce ie ed eh hese ce rst tke nbd ree ah battle eden ted aod 4 PX Cer ACT RACES unta nara 4 Dry Battery AC Adapter Installation ii A co 5 Dry Battery Installation ati diia ibas 5 Une on C Adap AAA AA A A AA A TELM RE OTE MET 5 Semne Phe Date And NN 6 Uta AS 7 User Willian ass 7 APPS AO aaa an Gena whee 8 A AAA A e 9 Accurate Micasurement Wa iii 9 BP Meastte mentsii di lo ii 9 Memory Func tiraediid 10 Review The Memory Val 10 Delete Memory Val ra 11 ALA Funcoms nna aaa 12 SPO2 Measurement Function Separate Sale oooooooonnnnncccconononnnnnnnnnonononononnncncncncnnnnnnnnnnnnononanos 12 Monitores Procede usina ida ar red 13 Maintenance dnd Cll 14 installation Or The Sot Winnie la das 15 Demand OR EdP aserat la a Error Bookmark not defined l sta on OF SOMA 15 Error Messe E E a E AEAT 16 TROUBLESHOOTING cosas 17 CVS ara Aa Mita sd 18 GA A A 18 S PEC ALI ON 3 xesrnaatiareasiciaaccspuic oascaonis dua da wu annua aaniec ena uiccmancnulc rua asa wisatua canna tuaaa E 19 Safety Precautions
3. O Before use carefully read Safety Precautions for a correct use O To prevent users suffered hurt or damnification due to improper use see Safety Precautions and use this product properly For safety reasons be sure to comply with safety precautions AN Note AN If not to use correctly it exists that a potentially hazardous situation which may result in injury to the user or patient or damage to the equipment or other property AN Note AN Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician Contact your physician for specific information about your blood pressure Please hand measurement results to the doctor who know your health to accept diagnosis For severe blood circulation disorder or arrhythmia patients please use the device under the guidance of a doctor Otherwise it may lead to acute hemorrhage or measurement error as a result of squeezed arm This device is intended for use in measuring blood pressure and pulse rate Do not use for any other purpose Otherwise it may cause accident or holdback Please use special cuff Otherwise it is possible that measurement result 1s incorrect Do not disassemble or attempt to repair the unit or components without permission Otherwise it can not measure correctly Operation for AC Adapter Separate Sale A Note A Please use sold separately dedicated AC adapter Otherwise 1t may cause trouble Sol
4. 803 233 3691 Fax 803 233 6140 E mail inquiries semedicalsupply com Website http www semedicalsupply com File No CMS2 782 021ESS 0 96 File Ver 1 01 Release Date July 2010 20
5. SYS DIS PR MAP 03125 84 53 94 2009 06 19 12 30 02 116 77 78 089 2009 06 19 12 30 01175 108 77 131 2009 06 18 12 30 EXIT TREND DOWN 4 Press TREND button to display trend interface mmHg SYS diff H DIA SYS 270 240 210 180 150 120 90 2009 06 18 2009 06 19 EXIT MEMORY 5 Finish displaying the measurement values Press EXIT to return the main interface or hold ON OFF button to turn the power off The monitor will automatically turn off after two minutes in which there is no operation to the device even 1f you forget to turn the power off Delete Memory Values Users can delete all values stored in the memory of each user separately instead of deleting a special item l Press MENU button to enter SYSTEM MENU select DELETE DATA item and enter its interface in which select the user whose data will be deleted All measurement results of selected user will be deleted after confirm 06 19 2009 12 30 30 FFA 06 19 2009 12 30 30 FFA 06 19 2009 12 30 30 FFA o SYSTEM SETUP ENTER USER 1 SYSTEM TIME ENTER V USER 2 ARE YOU SURE TO DELETE MASON EOS ARE YOU SURE TO DELETI MM CED THE DATA OF ALARM SETUI ALL USER SYSTEM MENI DATA DELETE USER 2 ENTER DOWN 4 ENTER DOWN CONFIRM 2 Finish Operation Select CONFIRM or EXIT to return the previous menu or hold ON OFF button to turn the power off The monitor will automatically
6. Housing to remove the AC Adapter from the electrical outlet Do not remove by pulling on the cord 2 Remove the AC Adapter plug from the monitor Please be sure to use dedicated AC adapter Model CMS0106 AN Note AN When adapter and dry battery are both used at the same time the battery power will not be consumed Switch adapter and battery as power supply when the device is off otherwise the device may shutdown due to power failure Setting The Date And Time It is necessary to set date and time after turning on the device The Blood Pressure Monitor automatically stores measurement results with date and time If dry battery power exhausts or removed then after the device turned on the date resumes from the last setting value and the time from 00 00 00 set the date and time again The Blood Pressure monitor stores the measure results of three users automatically and up to 100 items for every user The results can be uploaded to PC via USB and processed with the PC software If the date and time are set correctly the date and time when measuring will be correct in the memory otherwise it may not be correct A Note AN Correctly use data upload function 1 Turn on the device to enter the main interface shown as the follow amp 06 19 2009 12 30 30 CTAA 6 19 2009 12 30 30 USER USER2 MENI MEMORY 2 Press MENU button to enter SYSTEM MENU and select SYSTEM TIME item in system menu
7. connector of the SPO2 probe cable into the USB socket in the lower right of the monitor The main interface will switch to SPO2 interface This operation brings no affection to other functions amp 06 19 2009 12 30 30 FFA DATE 6 19 2009 12 305 30 SP02 PR Y 3 00 USER2 MENI MEMORY Measurement Limitations During operation the accuracy of oximeter readings can be affected by High frequency electrical noise including noise created by the host system or noise from external sources such as electrosurgical apparatus connected to the system Intravascular dye injections Excessive patient movement External light radiation Improper sensor installation or incorrect contact position of the patient SPO2 probe temperature optimal temperature between 28 C and 40 C Placement of the SPO2 probe on an extremity that has a blood pressure cuff arterial catheter or intravascular line 13 Significant concentrations of dysfunctional hemoglobin such as carboxyhemoglobin and methemoglobin SpO2 too low Bad circular injection of the part being measured It is required to use SPO2 probe which is provided by our company contact with our sale department when changes SPO2 probe Maintenance and Cleaning A Warning AN Take cuff off the power source before cleaning the monitor or the SPO2 probe A Caution A E Do not subject the sensor to autoclaving E Do not immerse the SPO2 probe into any l
8. turn off after two minutes in which there is no operation to the device even if you forget to turn the power off 11 Alarm Function Alarms are classified into two categories technical alarm and physiological alarm Physiological Alarm User can press MENU button to enter system menu select ALARM SETUP item to enter its interface and then set alarm on off and the high and low alarm limits when blood pressure is higher than the high limit or lower than the low limit the physiological alarm will occur 06 19 2009 12 30 30 Fa 2009 06 19 12 30 30 FFA SYSTEM MEN ty ALARM SETUP 4 SYSTEM SETUP ENTER ALARM OFF a SYS ALM HI mg 140 SYSTEM TIME ENTER DELETE DATA ENTE SYS AIM LO mmHg 90 ELETE DATA ENTER DIA ALM HI mig 90 Sencar DIA ALM LO mg 40 DEFAULT NO EXIT EXIT ENTER DOWN UP ENTER DOWN Press any button to cancel the alarm in physiological alarm state and this method brings no affection to the next alarm To close alarm in ALARM SETUP will disable the alarm function until switch alarm on Technical Alarm When power is about to exhaust and alarm is on then the alarm will occur This alarm can not be cancelled unless being closed or the power replaced SPO2 Measurement Function Optional Please pay attention to A Warning A Pulse oximeter can overestimate the SPO2 value in the presence of Hb CO Met Hb or dye dilution chemicals OES Electrosurgery equip
9. ESE The three buttons correspond with the hint in the LCD screen downside pressing any button will carry on corresponding function eg MENU ENTER LIST etc E Up and down buttons respectively carry on the functions of moving the cursor up and down changing the parameters and switching the status External Interfaces AN Note AN Please hold the air plug to remove the NIBP cuff DCuff Socket left side The right side of the instrument is USB socket and AC adapter socket USB socket E AC adapter socket right side Dry Battery AC Adapter Installation The production can use dry battery or AC adapter as power source Dry Battery Installation 1 Press the A indicator on the battery cover and slide the cover off in the direction of the arrow 2 Install 4 AA size dry batteries so the positive and negative polarities match the polarities of the battery compartment as indicated 8 Replace the battery cover Icon l bne batteries power will exhaust Replace with four new batteries the same sort at the same time Turn the unit off before replacing the batteries A Note A Dispose of the batteries according to applicable local regulations about environmental Using The AC Adapter 1 Connect Monitor and the AC Adapter Insert the AC Adapter Plug into the AC Adapter Jack on the right side of the monitor 2 Plug the AC Adapter into a 220V AC outlet AN Note AN Hold and pull the
10. System failure Cuff is not connected Loose cuff Correctly connect cuff refer to 8 page correctly Make sure the cuff plug is securely Air leakage Cuff plug fall off inserted in the windpipe refer to 8 page Air pressure error Air pressure error Keep arm body still measure again The pulse signal 1s too weak Weak signal Correctly connect cuff refer to 8 page or the cuff is loose Cuff is blocked or squeezed Correctly connect cuff refer to 8 page The signal extent 1s too big Excessive movement owing to the arm or body Over range moving or other reasons when Saturated signal Keep arm body still measure again measuring It takes too much time 16 TROUBLESHOOTING Abnormal Causes Solutions Phenomenons Correctly connect cuff refer to 8 Cuff is not connected correctly page BP measurement E Talk or move arms when Keep quiet and restart a values too high or l measuring measurement too low The turnup clothing presses the Take off the clothing which presses the arm and restart a measurement arm Cuff leakage Buy a new cuff ALE The cuff windpipe 1s not correctly Correctly connect connected with cuff Cuff deflates in short time It can not carry on measurement when press the Switch on the power once again measurement button and restart a measurement No use for a long time the power Power off suddenly l Replace all four batteries with new i of batteries can be exhausted when inflating l
11. The current time will be displayed 06 19 2009 12 30 30 FFA o SYSTEM SETUP ENTER SYSTEM TIME ENTER DELETE DATA ENTER ALARM SETUP ENTER 06 19 2009 12 30 30 FFA SYSTEM TIME SYSTEM MENI DATE 06 19 2009 TIME 12 30 30 EXIT CONFIRM EXIT UP ENTER DOWN UP ENTER DOWN Fl 3 Press UP or DOWN buttons to set date and time 4 After setting select CONFIRM item and press ENTER button to confirm the setting value If you do not want to change the time select EXIT item and press ENTER button to return the previous menu Unit There are two units mmHg and kPa The default is mmHg To switch mmHg and kPa units enter the SYSTEM SETUP submenuin SYSTEM MENU and complete switching in UNIT item 06 19 2009 12 30 30 FFA SYSTEM MENI tt SYSTEM SETUP SYSTEM TIME ENTER DELETE DATA ENTER ALARM SETUP ENTER EXIT ENTER DOWN User Switch 06 19 2009 12 30 30 FFA SYSTEM_SETUP 5 0 LANGUAGE ENG UNIT USER PURVIEW ALL MEASURE MODE ADU EXIT UP ENTER DOWN The Blood Pressure monitor stores the measure results of three users automatically and up to 100 items for every user Users can press USER button in main interface to switch user Or press USER PURVIEW item in SYSTEM SETUP menu to switch user SYSTEM SETUP tk o LANGUAGE ENG UNIT mmHg USER PURVIEW MEASURE MODE ENTER DOWN AN Note AN
12. and restart a measurement GIn no physiological alarm state press any button to carry on the corresponding button function in audio alarm state press any button except ON OFF button to clear up the audio alarm Take off the cuff hold ON OFF button to turn the monitor off The monitor will automatically turn off after two minutes in which there is no operation to the device even if you forget to turn the power off Memory Function The monitor is designed to store and display the blood pressure pulse rate values and the date and time when measured which are up to 100 items If there have been 100 items stored when the 101 measurement have been taken the earliest results are deleted Review The Memory Value 1 In the main interface interface when boot strap press MEMORY button to review the most recent measurement values in large print with the serial number from 1 to 100 06 19 2009 12 30 30 FFA USER 01 TOTAL 50 NO0 03 TIME 06 19 2009 12 30 12 mmhg AP PR Y 94 EXIT LIST DOWN e8 3 gt 2 Press UP DOWN button to circularly switch the former measurement values 06 19 2009 12 30 30 FFA USER 01 TOTAL 50 NO 03 TIME 06 19 2009 12 30 Y o gt un PR Y a EXIT LIST DOWN The right figure shows that there 1s no Measurement results 10 3 Press LIST button to switch to data table interface 06 19 2009 12 30 30 HFA NO
13. d separately dedicated AC adapter be sure to use the AC 220V Be sure to use a separate socket Otherwise it may cause electric shock or injury When there is breakage of sold separately dedicated AC adapter plug or wire please immediately pulled the plug from the socket Otherwise it may cause electric shock or injury Do not plug or unplug the adapter power cord with wet hands Otherwise it may cause electric shock or injury Operation for battery A Note A Please use 4 AA size manganese or alkaline batteries do not use batteries of other types Otherwise it may cause fire New and old batteries different kinds batteries can not be confusion Otherwise it may cause battery leakage heat rupture and damage to blood pressure and polarities of the batteries must match the polarities of the battery compartment as indicated When the batteries power exhausts replace with four new batteries at the same time Please take out the batteries when you do not use the device for a long time more than 3 months Otherwise it may cause battery leakage heat rupture and damage to blood pressure If battery fluid should get in your eyes immediately rinse with plenty of clean water Contact a physician immediately Otherwise it will cause blindness or other hazards If electrolyte of the batteries immodestly glues on the skin or the clothes immediately rinse with plenty of clean water Otherwise it may hurt the skin A Advice A Do n
14. iquid E Do not use any SPO2 probe or cable that may be damaged or deteriorated Cleaning NW Use a cotton ball or a soft mull moistened with hospital grade ethanol to wipe the surface of the SPO2 probe and then dry it with a cloth This cleaning method can also be applied to the luminotron and receiving unit E The cable can be cleaned with 3 hydrogen dioxide 70 isopropanol or other active reagent However connector of the SPO2 probe shall not be subjected to such solution 14 Installation Of The Software Computer requirements Pentium IV 1 8G or more Operation System Windows XP Pro or newer EMS memory 256M or more Hard Disk 40G or more Display 17 inch or more CD ROM USB 2 0 or newer Resolution of printer 600 DPI Installation Of Software 1 Place the CD ROM in the CD ROM compartment located on your computer 2 If Auto Play for CDs is enabled place CD in reader and follow instructions when they appear in the screen otherwise follow install instructions below 1 Open Windows Explorer 2 Click on the root CD ROM directory 3 Double click file ContecO8A_Setup EXE 4 Follow the instructions in the screen Refer to Software Help for details about the operation method of the PC software 15 Error Message Error message will be displayed in the screen if there is something wrong when measuring The causes and solutions are shown as follows Self test failure Function abnormal Please contact us
15. ment wire and SpO2 cable must not be tangled up Do not put the sensor on extremities with arterial catheter or venous syringe Do not perform SPO2 measuring and NIBP measuring on the same arm at one time because obstruction of blood flow during NIBP measuring may adversely affect the reading of SPO2 value AN Note AN Make sure the nail covers the light window Othe wire should be on the backside of the hand SPO value is always displayed in the fixed place AN Warning AN Check if the sensor cable is in normal condition before monitoring After unplugging the SpO2 probe cable from the socket the interface will return Do not use the SpO2 probe once the package or the sensor is found damaged Instead you shall return it to the vendor Prolonged and continuous monitoring may increase jeopardy of unexpected change of dermal condition such as abnormal sensitivity erubescence vesicle repressive putrescence Particularly in newborns or in a Perfusion disorders and changes or immature skin form of the patient According to skin quality change correct optical path alignment and attachment methods to regularly check the place of SPO2 probe and change the attachment position when the quality of skin decline More frequent examinations may be required for different patients Monitoring Procedure 1 Attach the sensor to the appropriate site of the patient finger as following figure place SPO2 2 Plug the
16. months 18 Specification Blood Pressure Monitor Harmful liquid proof Ordinary equipment sealed equipment without liquid proof degree 2 8 color LCD Display Pressure 0 290mmHg 0 36 0kPa Measurement Range Pulse 40 240 min Measurement Accuracy Cuff Pressure 3mmHg Accuracy The BP Value of the device is equivalence with the measurement value of Stethoscopy The error meets all the conditions in the YY0667 2008 Operating 5 C 40 C 15 RH 80 RH Temperature Humidity Transport and Storage 20 C 55 C lt 95 RH Temperature Humidit y Atmospheric pressure 80kPa 105kPa Battery 4 AA alkaline batteries AC Adapter AC 220V separately sold Main 130 110 80mm Dimensions Main Unit Weight 300gram Anti electroshock II class BF digital device type 19 Aeeessaries Normal Configure Adult Cuff limb circumference 22 32cm middle of upper arm Soft CD User Manual USB data line four AA alkaline batteries Separate Sale DC Adapter CMS0106 Input AC100 240V 50 60Hz AC 150mA Output DC 6 0V 0 2V 1 04 Manufacturer Qinhuangdao CONTEC MEDICAL SYSTEMS CO LTD Spo2 Probe Spo2 10UC15 Spo2 Measurement Range 35 100 Measurement Accuracy 70 100 2 Pulse Measurement Range 30 250bpm Manufacturer CONTEC MEDICAL SYSTEMS CO LTD gt CONTEC SOUTHEASTERN MEDICAL SUPPLY INC Address 1024 Wildwood Centre Dr Ste A Columbia SC 29229 Tel
17. ones owing to the changed temperature Power of batteries can be Replace all four batteries with new Hold the on off exhausted ones button but can not Check the battery installation for Loose cuff Correctly apply cuff start the device The battery polarities is reversed proper placement of the battery polarities Switch on the power once again and restart an operation Other phenomenon l Replace the batteries If no please contact us 17 Clean And Maintenance Please follow the instructions in the user manual If you do not comply our company will not assume responsibilities of the quality NW Frequently clean the Blood Pressure monitor NH If there is something dirty on the device clean it with a soft dry cloth WS NW If the unit is particularly dirty you can clean it with a soft cloth A dampened with water or neutral detergent after the cloth can be full twisted A Warning A Do not submerge the device in water A Advice A E Do not use any naphtha thinner or gas to clean E Do not attempt to clean or wash the cuff Keeping AN Advice A Do not place the machine in the following areas NW Easy to splash water areas Y E Direct sunlight extreme hot humidity dust causticity gas areas NW Lean or the area which can cause vibration impact NW Chemicals or corrosive gas storage areas NW Remove the batteries if the unit will not be used for long time more three
18. ot subject the monitor to strong shocks such as dropping the unit on the floor Do not inflate before the cuff wrapps around the arm Do not inflect the cuff and the air tube forcibly This device is intended for using in measuring blood pressure and pulse rate in the adult pediatric and neonatal population Main Unit The production is in the package Open the package and confirm whether the production is whole Display Cuff Plug Cuff Air UP DOWN Button MEMORY AC Adanter Tack MENU Button SWITCH USB Plug Jack ON OFF Button START STOP Button 5 Adult Cuff Dry Battery l l l l Accessories Specification limb circumference 22 32cm middle part of upper arm please choose suited cuff when measuring pediatric or other USB Data Line Software CD User Manual Separate Sale AC Adapter CMS0106 InputAC 100 240V 50 60Hz AC 1UmA Output DC 60V 0 2V 1 0A Spo2 Probe Spo2 10UCI5 Spo2 Measurement Range 35 100 Measurement Accuracy 70 100 2 Pulse Measurement Range 30 250bpm 3 Button Functions All the operations to the Electronic Blood Pressure Monitor are through the buttons The names of the buttons are above them They are ommna ON OFF Hold the button to start or close the device START STOP Press to inflate the cuff and start a blood pressure measurement When measuring press to cancel the measurement and deflate the cuff E
19. y The high and low location of cuff will cause changes in measurement results Do not touch BP monitor cuff and windpipe during measurement Measurements should be taken in a quiet place and the body is in relaxing state Remain still 4 5 minutes before measurement Relax the body do not let the muscle activity Do not talk and movement during the measurement Wait 4 5 minutes between measurements Do not use a cellular phone near the device BP Measurement OPress START STOP button to take a measurement 06 19 2009 12 30 30 TH 06 19 2009 12 30 30 TH START STOP Ao Start measurement measurement result During measurement please keep correct pose and quiet state do not move Stop Measurement During measurement if you wish to stop measuring press START STOP button to stop and deflate Confirm Measurement Value Measurement value can be automatically stored using memory function refer to 10 page Self diagnosis and treatment using measured results may be dangerous Follow the instructions of your physician AN Note A E Wait 4 5 minutes between measurements When repeated measurements because the arm appears congestion 1t may not get correct blood pressure measurement After the blood flow take a measurement once again E When some factors affect the measurement results in measurement process error messages hints will appear on the screen you can obviate the malfunction
Download Pdf Manuals
Related Search
Related Contents
Simeon 500WU - Simeon Canada Kenroy Home 32432DGRY Installation Guide MC Series Gas-Fired Circulating Heater 「Eagle View で楽しくラウンドして頂くために」 【電源 ON】 【充電】 【自動 Fujitsu LIFEBOOK U772 instrucţiune de funcţionare 取扱説明書 View Patient Information Leaflet 早期移行試験の受験について EMPLOYEE KIOSK USER GUIDE Copyright © All rights reserved.