DaqBoard/1000 and /2000 Series User`s Manual
Contents
1. gt N N one of the following S BE ESEVE PL PPEPE NO KOSO TBONO VOPFOCA PO DBK201 DBK202 DBK203 DBK204 U S D P PNSESHSPLEPEVNVES DBK208 se br AASS DBK209 63 Digital VO Port C Digital I O Port A The P2 DB37 connector Pins 22 thru 29 Pins 30 thru 37 does not apply to DBK200 DBK205 DBK207 or DBK207 CJC ng Signal Name Description for P2 Pin Use pr Correlation 1 JNotConnected INA NA k 2 NotConnected INA 3 PotB B7 I O P2 Digital Port B Bit 7 or P2 Expansion Address Bit 0 Out Digital VO P2 Digital Port B Bit 6 or P2 Expansion Address Bit 1 Out Digital I O P2 Digital Port B Bit 5 or P2 Expansion Address Bit 2 Out 6 PotB B4 1 Digital I O P2 Digital Port B Bit 4 or P2 Expansion Address Bit 3 Out Digital VO P2 Digital Port B Bit 3 or P2 Expansion Address Bit 4 Out 8 JPortB B2 Digital I O P2 Digital Port B Bit 2 or P2 Expansion RESET Output A13 59 1 Pot B B1 I Digital O P2 Digital Port B Bit 1 or P2 Expansion WRITE Output I Bi Ground oigtal Common See Ground Corea Tato page STE NE N A 13 Ground Digital Common See Ground Correlation Tables page 3 15 lt NA S N A 48 Gad pig men e rand Corin Tabs page Ee 16 NotConnected INA N A aS nn i Ground gat Common S80 Ground Corelien Tables pago 318 E Digital VO P2 Digital Port C Bit 7 or P2 Expansion Data Bit 7 A6 Digital I O P2 Digital Por
2. 4 External scanning input clock Digital I O Applicable to DaqBoard 2000 12001 12002 12004 12005 Channels 40 expandable to 208 vvith external DBK options Input Scanning Modes 2 1 Asynchronous under program control at any time relative to input scanning 2 Synchronous vvith input scanning Ports 3 x 8 bit 82C55 emulation and 1 x 16 bit Each port is programmable as input or output Input Characteristics 100 series 20 pF to common Input protection 8 kV ESD clamp diodes parallel I O levels TTL Sampling Update rate 200 kHz maximum 7 4 Specifications DaqBoard 2000 Series 889094 Note Specifications subject to change without notice Pattern Generation Output Applicable to DaqBoard 2000 2001 2002 2004 2005 The P3 16 bit digital I O port can be configured for 16 bit pattern generation The pattern can be updated synchronously with an acquisition from a file If pattern generation mode is utilized then the D A outputs can only be used in an asynchronous mode Bus mastering DMA provides CPU and system independent data transfers insuring data acquisition performance irrespective of other system activities Streaming from disk or memory is supported allowing continuous nearly infinite length pattern outputs limited only by available PC system resources Frequency Pulse Generators Applicable to DaqBoard 2000 12001 12002 12004 12005 Channels 2 x 16 bit Output Waveform Square wave Output rate 1 MHz base r
3. CE standards were developed by the European Union EU dating from 1985 and include specifications both for safety and for EMI emissions and immunity Now all affected products sold in EU countries must meet such standards Although not required in the USA these standards are considered good engineering practice since they enhance safety while reducing noise and ESD problems In contracted and in house testing most Daq products met the required specifications Those products not originally in compliance were redesigned accordingly In some cases alternate product versions shield plates edge guards special connectors or add on kits are required to meet CE compliance CE compliant products bear the CE mark and include a Declaration of Conformity stating the particular specifications and conditions that apply The test records and supporting documentation that validate the compliance are kept on file at the factory CE Standards and Directives The electromagnetic compatibility EMC directives specify two basic requirements 1 The device must not interfere with radio or telecommunications 2 The device must be immune from electromagnetic interference from RF transmitters etc The standards are published in the Official Journal of European Union under direction of CENELEC European Committee for Electrotechnical Standardization The specific standards relevant to Daq equipment are listed on the product s Declaration of Confo
4. DaqBoard 1000 and 2000 Series User s Manual For PCI bus amp Compact PCI bus Data Acquisition Boards Measurement Computing 10 Commerce Way Norton MA 02766 508 946 5100 Fax 508 946 9500 info mccdag com www mccdag com DaqBoard 1000 amp 2000 Series User s Manual For PCI bus amp Compact PCI bus Data Acquisition Boards pin 1033 0901 rev 8 0 O 1999 through 2005 by 889094 Printed in the United States of America Warranty Information Contact Measurement Computing by phone fax or e mail in regard to warranty related issues Phone 508 946 5100 fax 508 946 9500 e mail info amccdaq com Limitation of Liability Measurement Computing cannot be held liable for any damages resulting from the use or misuse of this product Copyright Trademark and Licensing Notice All Measurement Computing documentation software and hardware are copyright with all rights reserved No part of this product may be copied reproduced or transmitted by any mechanical photographic electronic or other method without Measurement Computing s prior written consent IOtech product names are trademarked other product names as applicable are trademarks of their respective holders All supplied IOtech software including miscellaneous support files drivers and sample programs may only be used on one installation You may make archival backup copies CE Notice Warnings Many Measurement Computing products ca
5. kj J E E 2 3 ry oe if DEK 1 ai bl A feet Til Last J V I rest ro peo rro dani ar TE 0 2 f r 9 po K T Ke je ye Fag E N s vr n SUND ob Q ae aay Seeesecssenevess cosseseesceensege 2000020e00000000 seesneosscosespose DBK210 Carrier Board for Grayhill 70M Series Mini Modules DaqBoard 1000 and 2000 User s Manual 898195 Connections amp Pinouts DaqBoard 2000 Series 3 7 Pinouts for DaqBoard 2000 Series and 2000c Series Boards Reference Notes You must set up DaqView for the particular DBKs in your system If you are unfamiliar with the method of setting up DBKs in DaqView or if you need a refresher refer to the following documents as needed gt The DBK Set Up in DaqView chapter of the DBK Option Cards Modules User s Manual p n 457 0905 gt The DBK Option Cards Modules User s Manual p n 457 0905 for the applicable DBK document module s The documentation discusses hardware configuration aspects that require setup in software gt The DaqView document module During software installation documentation is automatically installed onto your hard drive as a part of product support The default location is the Programs directory which can be accessed through the Windows Desktop Note As new DBKs become available be sure to use the latest revision of Dag View with the proper configuration options The following P1 P2 and P3 connector pinouts pertain to the D
6. 00154005 1 25t0 25V 00154008 1 1 25t0 125V 00154008 2 0 62510 0625V 00154008 2 0 3125 t0 0 3125V 00154008 3 0 156 to 0 156V_ 00240088 3 Notes 1 Specifications assume differential input single channel scan 200 kHz scan rate unfiltered 2 Accuracy specification is exclusive of noise Measurements were taken at P1 3 Inputs shorted to signal ground SGND 8192 samples Note Specifications subject to change without notice 889094 Specifications DaqBoard 1000 Series 6 1 A D Specifications Applicable to DaqBoard 1000 11005 Type Successive approximation 200 kHz maximum conversion rate Resolution 16 bits Conversion Time 5 us Maximum Sample Rate 200 kHz Differential Nonlinearity 2 LSB maximum Integral Nonlinearity 1 LSB maximum Missing Codes None over full operating temperature range Input Sequencer Applicable to DaqBoard 1000 11005 Analog digital and counter inputs can be scanned synchronously based either on an internal programmable timer or an external clock source Analog and digital outputs can be synchronized to either of these clocks Scan Clock Sources 2 1 Internal programmable from 5 us to 5 96 hours maximum in 1 us steps 2 External TTL level input up to 200 kHz maximum Programmable parameters per scan channel random order gain Depth 512 location On board Channel to channel scan rate 5 or 10 us per channel programmable External Acquisition Scan C
7. Test Results No tests have been run Torun click Test includes a troubleshooting chapter as well as a great OK C Apply deal of information regarding specific DBK cards and Cancel e modules Test Hardware Tab Condensed Screen Image Note If you experience difficulties please consult your user documentation included on your CD before calling for technical support Note that the user documentation At this point we are ready to connect signals This is typically accomplished with the use of a DBK200 Series option 1061 0940 rev 4 0 979294 DaqBoard 2000c Series Installation Guide IG 5 IG 6 DaqBoard 2000c Series Installation Guide 979294 1061 0940 rev 4 0 Daq Systems and Device Overviews 1 Daq Systems the Modular Concept 1 1 Theory of Operation DaqBoard 1000 and 2000 Series Boards 1 3 DaqBoard 1000 1 7 DaqBoard 1005 1 9 DaqBoard 2000 1 11 DaqBoard 2001 1 13 DaqBoard 2002 1 15 DaqBoard 2003 1 17 DaqBoard 2004 1 19 DaqBoard 2005 1 21 Using DBK Cards and Modules for Signal Conditioning 1 23 Daq Software 1 23 Daq Systems the Modular Concept Daq equipment and software form a modular interrelated family of products that provide great flexibility in data acquisition system design This flexibility allows for the development of custom systems that are unique to the user and which can be optimized for his or her specific
8. The lower lock screw is accessed through an opening on the injector ejector as indicated in the right hand figure ge Injector Ejector and Lower Lock Screw 1061 0940 rev 4 0 979294 DaqBoard 2000c Series Installation Guide IG 3 12 Plug in all cords and cables that were removed in step 3 13 Apply power to and start up the PC Note At this point some PCs may prompt you to insert an installation disk While this is rare if you do receive such a prompt simply place the install CD into the disk drive and follow the screen prompts Securing a DaqBoard 2000c Series Board Step 3 Configure Boards DaqBoard 2000c Series boards have no jumpers or switches to set Configuration is performed entirely through software Refer to the following figure and steps to complete the configuration The numbers in the figure correspond to the numbered steps immediately following the figure Address aa Control Panel SB Add New Hardware s f hy Add R emove Programs Daq Configuration E Versi Daq Driver ES Corel Versions Configuration Utility Daq Configuration ir Device Inventory Computer DaqBoard2K0 2 Sy DagBookO N Properties _ Add Device Close 3 4 Daq Configuration DaqBoard 2000 Properties Test Hardware Device Settings Device Name DaqBoara2Ko 3 Device Type DagBoard 2000 X 4 DagBoard 2000 Series Hardware Bus 0 Slot 12 S N 18281
9. eel os TB1 4 DACI 100 kHz mi me sis aono fe i TB1 7 AGND TB1 8 DAC3 ee T Note DBK205 ts directly t ote connects directly to oer ao 3 DaqBoard 2003 s or 2003c s GRE an F P4 connector Address Bus TB1 12 DGND TA tE DBK205 Adapter DaqBoard 2003 Block Diagram DBK206 The DBK206 provides a P1 P2 and P3 connector and corresponding screw terminal blocks e PI is used for ANALOG I O e P2 for DIGITAL I O e P3 for Pulse Frequency Digital and Counter Timer I O ry s E aaan n n a a sa go DBK206 P4 to P1 P2 P3 Adapter with Screw Terminals The DBK206 is suitable for both analog and digital expansion Signal connection to a DaqBoard 2000 Series or to a DaqBoard 2000c Series board can be made as follows e With cables connected to P1 P2 and P3 connectors as applicable With signal wires connected to the appropriate screw terminal blocks TB1 through TB 12 Note that the DBK206 board s silkscreen identifies all screw terminals e With a combination of the above two methods Regardless of which method is used the DBK206 connects to the 100 pin P4 connector of a DaqBoard 2000 Series or a 2000c Series board The connection is made via a CA 195 cable The board contains mounting holes that allow the board to be secured inside a user provided enclosure Note Board images are not to the same scale 3 4 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User
10. i Controler Controller PLD EEPROM Address Bus DaqBoard 2000 Block Diagram The DaqBoard 2000c Block Diagram is the same with exception that the 2000c board uses a compact PCI Bus instead of a standard PCI bus Connections Installation VO Connectors Reference Note For the DaqBoard 2000 and DaqBoard 2000c installation procedure refer to either the DaqBoard 1000 and 2000 Series Installation Guide or to the DaqBoard 2000c Series Installation Guide as applicable The guides are included at the beginning of this manual All input and output signals are available at the board s 100 pin P4 connector A 3 foot 100 conductor ribbon cable part number CA 195 mates with connector P4 Reference Note There are several P4 connector board options available for connecting the 100 pins of P4 to typical DB37 connectors P1 P2 and P3 In addition to being briefly discussed in chapter 3 of this manual these options referred to as DBK200 Series are detailed in the DBK Cards and Modules User s Manual p n 457 0905 1 12 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 2001 Digital y on 16 Analog 4 Analog 40 Digital 4 Counter 2 Timer Input Output I O Inputs Outputs DaqBoard 2001 and DaqBoard 2001c are high speed multi function plug and play data acquisition boards for PCI or compact PCI bus computers respectively They feature a 16 bit 200 kHz A D c
11. 100 which is an optional terminal board connector Chapter 3 Connections and Pinouts DaqBoard 2000 Series This chapter includes board pinouts for the DaqBoard 2000 Series boards 100 pin connector P4 The chapter includes an overview of the DBK200 Series P4 adapters that can be used to obtain DB37 type connectors Pl P2 and P3 Chapter 4 CE Compliance pertains to CE standards and conditions that are relevant to DaqBoard 1000 and 2000 Series boards A CE Kit which can be used for DaqBoard 2000 Series boards is also discussed Chapter 5 Calibration lists the order in which to perform calibration related adjustments and briefly discusses DaqCal exe a program that provides on screen instruction graphics and prompts Chapter 6 Specifications DaqBoard 1000 Series Boards Chapter 7 Specifications DaqBoard 2000 Series Boards Glossary Reference Notes During software installation Adobe PDF versions of user manuals are automatically installed onto your hard drive as a part of product support The default location is in the Programs directory which can be accessed from the Windows Desktop A copy of the Adobe Acrobat Reader is included on your CD The Reader provides a means of reading and printing the PDF documents Note that hardcopy versions of manuals can be ordered from the factory gt DaqViev and DaqViewXL explains the use and features of the included out of the box data acquisition software
12. 5 us The trigger can be programmed for logic level or edge triggering In pattern triggering any of the digital input ports acts as the trigger port You can program the digital pattern e Software based triggering The PC detects the trigger event from readings digital or counter Six pre and post triggering modes are supported Other features of the DaqBoard 2002 include e 40 TTL level digital I O lines They are divided into three 8 bit ports and one 16 bit port e Four 16 bit counters Each can accept frequency inputs up to 10 MHz The counters can be cascaded into two 32 bit counters e Two 16 bit timer outputs Each can generate square waves from 16 Hz to 1 MHz e Configuration through software There are no switches or jumpers on a DaqBoard 2002 DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 15 SIGNAL VO PPS0999S5 590999 S 000099598009 999050079 9950000999806 TT DO000000000000000000000000000000000000000000000000 FS 512 step Random Access i Channel iGain Sequencer FIFO DIGITAL Data CONTROL Sequencer Reset Buffer E Programmable J Sequencer Timebase DIGITAL VO 5 p to 6 hours System i PCI Controler Controller PLD EEPROM Address Bus DaqBoard 2002 Block Diagram The DaqBoard 2002c Block Diagram is the same with exception that the 2002c board uses a compact PCI Bus instead of a standard PCI bus Connections Installation Reference Note
13. Bus DaqBoard 1000 Block Diagram Connections Installation Reference Note For the DaqBoard 1000 installation procedure refer to the DaqBoard 1000 and 2000 Series Installation Guide A copy of the guide is included at the beginning of this manual VO Connectors All input and output signals are available at the board s 68 pin SCSI III connector Chapter 2 includes a pinout The following cable and terminal board options can be used to provide convenient screw terminal connections for all signal I O lines Mating Cable The CA G56 is a 68 conductor shielded cable It is used to connect a DaqBoard 1000 Series board to a TB 100 termination board The cable length is 3 feet TB 100 TB 100 is an optional termination board It provides convenient screw terminal connections for all signal I O lines of a DaqBoard 1000 Series board Reference Note The TB 100 terminal board connection option is discussed in chapter 2 1 8 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 1005 Digital alot oon 16 Analog 24 Digital 4 Counter 2 Timer Inputs I O Inputs Outputs DaqBoard 1005 is a high speed multi function plug and play data acquisition board for PCI bus computers It features a 16 bit 200 kHz A D converter digital calibration bus mastering DMA 24 digital I O lines four counters and two timers Up to four boards can be installed into a PC One 68 pin SCSI III connector on
14. For the DaqBoard 2002 and compact PCI DaqBoard 2002c installation procedure refer to either the DaqBoard 1000 and 2000 Series Installation Guide or to the DaqBoardi2000c Series Installation Guide as applicable The guides are included at the beginning of this manual VO Connector All input and output signals are available at the board s 100 pin P4 connector A 3 foot 100 conductor ribbon cable part number CA 195 mates with connector P4 Reference Note There are several P4 connector board options available for connecting the 100 pins of P4 to typical DB37 connectors P1 P2 and P3 In addition to being briefly discussed in chapter 3 of this manual these options referred to as DBK200 Series are detailed in the DBK Cards and Modules User s Manual p n 457 0905 1 16 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 2003 4 Analog Outputs DaqBoard 2003 and 2003c are high speed plug and play data acquisition boards for PCI and compact PCI bus computers respectively The boards are used for analog output and include four 16 bit 100 kHz D A converters Up to four boards can be installed into a PC A 100 pin connector on the boards provides access to the DAC analog output signals The boards plug directly into a PCI or compact PCI bus slot as applicable The DAC analog output leaves the board through P3 designated pins located on the board s 100 pin P4 connector
15. TB1 DBK205 s TBI includes screw terminals for DACO DACI DAC2 and DAC3 1 digital ground 5 analog grounds 1 external clock CLK and 1 external trigger XTTL DBK205 connects directly to DaqBoard 2003 s P4 connector or to a compact PCI DaqBoard 2003c s P4 connector DBK205 is depicted as part of the block diagram above and is discussed briefly in chapter 3 of this manual DBK205 is also discussed in the DBK Cards and Modules User s Manual p n 457 0905 DaqBoard 1000 and 2000 Series User s Manual 889094 Daq Systems and Device Overviews 1 17 1 18 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 2004 Digital oe el GO 4 Analog 40 Digital 4 Counter 2 Timer Output I O Inputs Outputs DaqBoard 2004 and 2004c are high speed multi function plug and play data acquisition boards for PCI and compact PCI bus computers respectively They feature bus mastering DMA four 16 bit 100 kHz D A converters 40 digital I O lines four counters and two timers Up to four boards can be installed in one PC A 100 pin connector on the boards provides access to all of the input and output signals Each board accommodates all I O with one cable and one PCI or compact PCI slot as applicable The 100 pin I O connector P4 is logically divided into three ports Pl P2 and P3 however DaqBoard 2004 only makes use of the P2 and P3 pin designations e P1 Not used by DaqBoard
16. a bare board DBK203 Filter Setup consists of a DBK202 mounted ina chassis DBK204 consists of a DBK203 and a CA 209 CE cable kit Only used with DaqBoard 2003 or 2003c Can plug directly into P4 Screw terminals are related to P3 Similar to DBK202 but has a different form factor and has no RC filter setup Can carry Supports 5B compatible Analog I O 5B modules modules DBK207 CJC includes Cold Junction Compensation Includes two P1 connectors Screw terminals are for 5B module connections Can carry Supports Opto 22 compatible Solid State Qty 2 relay modules Relay SSR digital modules Includes two P2 connectors es ah Rl Ne Like DBK201 except for form factor Can carry Supports 32 channels of digital I O via Qty 2 digital VO Grayhill 70M Series mini modules modules DBK200 Series P4 Connector Options Reference Note Prior to connecting a DBK to a DaqBoard 2000 Series or 2000c Series board refer to the applicable DBK document module s in the DBK Option Cards and Modules User s Manual p n 457 0905 During software installation the manual is automatically installed onto your hard drive as a part of product support The default location is the Programs directory which can be accessed through the Windows Desktop 200 201 gt 202 203 204 T 0 207 207 CJC Qty 2 D D OD N N N 3 ND ND N JN JN DBK200 The DBK200 P4 to P1 adapter board provides a DB37 Pl connector P
17. and 2000 Series User s Manual 959495 Calibration 5 1 5 2 Calibration 959495 DaqBoard 1000 and 2000 Series User s Manual Specifications DaqBoard 1000 Series Boards I O Comparison Matrix for DaqBoard 1000 Series Boards DaqBoard Analog Input Analog Output Digital I O Counter Timer I dentity Channels Channels Channels Inputs Outputs General Specifications Applicable to DaqBoard 1000 11005 Analog Inputs Warm up 1 hour to rated specifications Supply voltage range 4 75 VDC to 5 25 VDC PCI bus Power consumption per board 3 5 W Operating temperature 0 to 60 C Storage temperature 40 to 80 C Relative Humidity 0 to 95 non condensing Vibration MIL STD 810E Signal I O Connector 68 pin SCSI type III carries all analog I O and digital I O Dimensions 165 mm W x 15 mm D x 108 mm H 6 5 x 0 6 x 4 2 Weight 160 g 0 35 Ibs Applicable to DaqBoard 1000 1005 Channels 16 single ended or 8 differential programmable on a per channel basis as single ended or differential bipolar Bandwidth 500 kHz Settling Time 5 us maximum to 1 LSB for full scale step Maximum Input Voltage 11V relative to analog common Over Voltage Protection 35V Ranges Software programmable via sequencer on a per channel basis Voltage Range Accuracy Note 2 Input Noise Note 3 Note 1 One Year 0 to 35 C LSB rms reading range 10 Hz to 200 kHz Absolute Typical 10 to 10 V 0 015 005 Bto 5V
18. application needs With the Daq product line system expansion or redesign can typically be accomplished with relative ease e Primary Acquisition Device This is the main data acquisition device e g a DaqBook DaqBoard or Daq PC Card These devices provide a vital data conversion and communications link between the data source of transducers and signal conditioners and the data processor of the host computer Note that a DaqBoard can be one of three types 1 ISA 2 PCI or 3 compact PCI e DBK Option Cards and Modules Over 35 DBK cards and modules the number is constantly growing provide various types of signal conditioning and system expansion Note that certain DBK modules exist for the purpose of supplying power to other members of the acquisition system The DBK options are discussed in a DBK Basics document module and in the detailed DBK Option Cards and User s Manual p n 457 0905 DaqBoard 1000 Series boards do not support DBK options Note Only passive DBKs such as the DBK1 BNC module the DBK11A screw terminal card and the DBK40 BNC analog interface can be used with a Daq PC Cards Reference Note DBK options are discussed in the DBK Option Cards and Modules User s Manual pin 457 0905 As a part of product support this manual is automatically loaded onto your hard drive during software installation The default location is the Programs directory which can be accessed through the Windows Desktop e Software
19. channel All D A channels available may have output streamed to them and clocked out synchronously The D A channels may be configured for waveform output The DaqBoard 2000 Series boards allow synchronous output of any D A or P3 16 bit Digital channels available at up to 100kHz for each channel All D A channels available and the 16 bit P3 Digital channel may have output streamed to them and clocked out synchronously The D A channels may be configured for waveform output and the P3 digital channel may be configured for streamed digital pattern output using the same clock sources Output Channel Configuration Analog Output Channels Each D A channel can be configured for waveform output individually If the D A channel is not configured for waveform output it then is available for asynchronous output operations Digital Pattern Output Channel DaqBoard 2000 Series Only In regard to DaqBook 2000 Series boards the 16 bit P3 Digital Port can be configured for streamed digital pattern output If not configured for streamed digital pattern output operations it then may be used for asynchronous digital I O operations Synchronous Output Clocking Associated boards allow clocking of the synchronized output by the acquisition clock source an internal programmable pacer clock or by an external clock source When the clock source generates a new clock signal all outputs are updated concurrently Regardless of the clock source the clock may not excee
20. drivers for third party icon driven software such as DASYLab and LabView e various language drivers to aid custom programming using API Ready to use programs are convenient for fill in the blank applications that do not require programming for basic data acquisition and display e DaqView is a Windows based program for basic set up and data acquisition DaqView lets you select desired channels gains transducer types including thermocouples and a host of other parameters with a click of a PC s mouse DaqView lets you stream data to disk and display data in numerical or graphical formats PostView is a post acquisition waveform display program within Daq View e DaqViewXL allows you to interface directly with Microsoft Excel to enhance data handling and display Within Excel you have a full featured Daq control panel and all the data display capabilities of Excel e Post acquisition data analysis programs e g PostView DIAdem and eZ PostView typically allow you to view and edit post acquisition data e The Dag Configuration control panel allows for interface configuration testing and troubleshooting Each Daq system comes with an Application Programming Interface API API language drivers include C C and Visual Basic The latest software is a 32 bit version API DaqBoard 1000 and 2000 Series User s Manual 889094 Daq Systems and Device Overviews 1 23 Reference Notes gt The software document modules DaqView DaqVi
21. engage the board 6 Tighten the upper and lower lock screws Lower Lock Screw Installing a cPCI DaqBoard 2000c Series Board Connect the CA 195CE Cable to the Board Note This section includes illustrations depicting the DaqBoard 2000 but apply to both the DaqBoard 2000 Series Boards and the cPCI DaqBoard 2000c Series Boards CA 195CE Cable Connected to DaqBoardi 2000 Grounding Pigtail CE ORB and Cable Clamp Connects to DBK203 DBK203 s P4 Copper Band Cable Clamps Part of Cable 2 Places Note When mating P4 connectors ensure that the P4 white locator triangles point to each other The triangles locate pin Al 1 Connect one end of the CA 195CE Cable to DaqBoard 2000 Series or 2000c Series Board s P4 connector Note that either end of the cable can be connected to the board however the white locator triangles must align with each other 2 Align the Cable Clamp 1033 2009 with the Cable Clamp 1033 2009 CE ORB and secure the items with two BB 4 40 x 3 16 screws provided DaqBoard 2000 Note In the right hand figure the cable is not shown to allow for greater clarity of parts ee Si RS p 1 I 8 Screw 4 40 x 3 16 1 of 2 DaqBoard 1000 and 12000 Series User s Manual 959495 CE Compliance 4 5 Secure the Grounding Pigtail to Cable CA 195CE Using Cable Clamps 1033 2009 1033 2010 and two 4_40 x 5 16 screws secure the Grounding Pigtail to
22. for developing custom programs using API commands p n 1008 0901 DBK Option Cards amp Modules User s Manual p n 457 0905 7 6 Specifications DaqBoard 2000 Series 889094 Note Specifications subject to change without notice Glossary Acquisition Analog Analog to Digital Converter ADC API Bipolar Buffer Buffer Amplifier Channel Common mode Common mode voltage Crosstalk Digital Glossary A collection of scans acquired at a specified rate as controlled by the sequencer A signal of varying voltage or current that communicates data A circuit or device that converts analog values into digital values such as binary bits for use in digital computer processing Application Program Interface The interface program within the Daq system s driver that includes function calls specific to Daq hardware and can be used with user written programs several languages supported A range of analog signals with positive and negative values e g 5 to 5 V see unipolar Buffer refers to a circuit or device that allows a signal to pass through it while providing isolation or another function without altering the signal Buffer usually refers to a A device or circuit that allows for the temporary storage of data during data transfers Such storage can compensate for differences in data flow rates In a FIFO First In First Out buffer the data that is stored first is also the first data to lea
23. modules with dynamic channel and gain range selection allow for high channel to channel scan rates with a variety of transducers Note Only passive DBKs such as the DBK1 BNC module the DBK11A screw terminal card and the DBK40 BNC analog interface can be used with Daq PC Cards DBK output signals can be bipolar e g 5 to 5 V or unipolar e g 0 to 10 V The user can select a range of relevant values to correspond to the lowest signal e g 5 or 0 V and the highest signal e g 5 or 10 V signal This type of range selection guarantees the highest resolution in 12 bit or 16 bit conversion DBK modules share the same footprint as the DaqBook and a typical notebook PCs allowing for convenient stacking The majority of these modules have their own power supply however several options exist for packaging and powering the DBKs Reference Note DBK options are detailed in the DBK Option Cards and Modules User s Manual p n 457 0905 As a part of product support this manual is automatically loaded onto your hard drive during software installation The default location is the Programs directory which can be accessed through the Windows Desktop Daq Software The Daq devices have software options capable of handling most applications Three types of software are available e ready to use graphical programs e g DaqVievv DaqViewXL and post acquisition data analysis programs such as PostView DIAdem and eZ Post View e
24. of dangerous switch loads Do not operate such switch loads unless emergency over ride circuitry is present Note DBK208 is not used with DaqBoard 2003 DBK208 boards are typically installed in NEMA type panels however they may alternatively be installed on DIN rails Separate mounting instructions are included with Rack Mount Kit part no Rack DBK 3 and with DIN rail Mount Kit part no DIN DBK 1 In regard to the DaqBoard 2000 Series and DaqBoard 2000c Series boards control originates in the board s 100 pin P4 connector Connection of these boards to DBK208 can be made directly or indirectly as follows e Direct connection can be made from the DaqBoard 2000 Series or 2000c Series board s 100 pin P4 connector to a DBK208 s P4 connector via a CA 195 cable e Indirect connection can be made using an additional DBK200 Series P4 adapter that includes a 37 pin P2 connector For example one of the following could be used DBK201 DBK202 DBK203 DBK204 DBK206 DBK209 or another DBK208 CA 37 cables are used to connect from P2 to P2 Note that a single Daq based data acquisition system can support up to 16 DBK208 boards providing a total of 256 channels DBK208 boards contain two DB37 P2 connectors for the purpose of daisy chaining to other DBK208s or to other P2 supported devices 3 6 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User s Manual DBK209 The DBK209 is a mini adapter board suit
25. programmable device that manages channels and channel specific settings An operation that gathers samples from multiple channels at the same instant and holds these values until all are sequentially converted to digital values The single ended mode measures a voltage between a signal line and a common reference that may be shared with other channels Also see differential mode 959395 Glossary An event to start a scan or mark an instant during an acquisition The event can be defined in various ways e g a TTL signal a specified voltage level in a monitored channel a button manually or mechanically engaged a software command etc Some applications may use pre and post triggers to gather data around an instant or based on signal counts Trigger TTL Transistor Transistor Logic TTL is a circuit in which a multiple emitter transistor has replaced the multiple diode cluster of the diode transistor logic circuit typically used to communicate logic signals at 5 V A range of analog signals that is always zero or positive e g 0 to 10 V Evaluating a signal in the right range unipolar or bipolar allows greater resolution by using the full range of the corresponding digital value See bipolar Unipolar Glossary 959395 G 3 G 4 959395 Glossary
26. s Manual DBK207 and DBK207 CJC The DBK207 and DBK207 CJC are carrier boards for 5B compatible analog input modules They each provide two PI connectors for ANALOG I O a 5 VDC power terminal e footprints for sixteen 5B Modules e 16 terminal blocks In addition DBK207 CJC provides Cold Junction Compensation The DBK207 and DBK207 CJC each include a 100 pin P4 connector for use with DaqBoard 2000 Series and cPCI DaqBoard 2000c Series Boards DBK207 CJC Carrier Board for 5B Compatible Modules WARNING Ensure that hard wire emergency over ride circuitry exists for all applications that make use of dangerous switch loads Do not operate such switch loads unless emergency over ride circuitry is present DBK207 and DBK207 CJC are typically installed in NEMA type panels however they may be installed on DIN rails Separate mounting instructions are included with Rack Mount Kit part no Rack DBK 3 and with DIN rail Mount Kit part no DIN DBK 1 DBK207 and DBK207 CJC allow Daq based acquisition systems to use various combinations of sixteen 5B signal conditioning modules 5B modules can accommodate a variety of signals including low level thermocouple and strain gage signals Configuration options are flexible You can select the type of signal attached to each channel One Daq device can support up to 16 DBK207 or DBK207 CJC boards providing a maximum of 256 isolated analog input channels Note that Daq devices scan th
27. the board provides access to all of the input and output signals The DaqBoard 1000 accommodates all I O with one cable and one PCI slot The 68 pin I O connector is logically divided into three functions e Analog input forl6 single ended or 8 differential analog inputs with 7 software programmable bipolar ranges 10 V to 156 mV full scale e 24 lines of general purpose digital I O e A counter inputs and 2 timer outputs The on board scan sequencer lets you select up to 512 channel range combinations The sequencer scans all channels of the scan at 5us channel or 10 us channel Bus mastering allows analog and digital counter input data as well as digital output data to flow between the PC and the DaqBoard without consuming CPU time DaqBoard 1005 supports trigger modes that include e Digital and pattern triggering The boards have separate digital trigger input line allowing TTL level triggering and latencies less than 5 us The trigger can be programmed for logic level or edge triggering In pattern triggering any of the digital input ports acts as the trigger port You can program the digital pattern e Software based triggering The PC detects the trigger event from analog digital or counter readings Six pre and post triggering modes are supported Other features of the DaqBoard 1000 include e 24 TTL level digital I O lines They are divided into three 8 bit ports e Four 16 bit counters Each can accept frequen
28. 2004 e P2 General purpose digital I O port with 24 lines or digital I O expansion port controlling up to 192 external lines e P3 16 bit digital I O port counter inputs timer outputs and analog outputs The on board scan sequencer lets you select up to 512 channel range combinations The sequencer scans all channels of the scan at 5 us or 10 us per channel Bus mastering allows the digital counter input data and analog and digital output data to flow between the PC and the DaqBoard 2004 without consuming CPU time DaqBoard 2004 supports several trigger modes including e Digital and pattern triggering Each board has a separate digital trigger input line allowing TTL level triggering and latencies less than 5 us The trigger can be programmed for logic level or edge triggering In pattern triggering any of the digital input ports acts as the trigger port You can program the digital pattern e Software based triggering The PC detects the trigger event from readings either analog digital or counter Six pre and post triggering modes are supported The four 16 bit 100 kHz analog output channels have an output from 10 V to 10 V Using Bus Mastering DMA each D A can output a waveform Bus Mastering DMA also allows for digital pattern generation on the 16 bit high speed digital I O port Other features of the DaqBoard 2004 include e 40 TTL level digital I O lines They are divided into three 8 bit ports and one 16 b
29. 34 Digital 1 O Line AO AGND AnalogCom note Digital 1 O Line Al ACH1 33 Digital 1 O Line A2 ACH9 Digital 170 Line A3 AGND AnalogCom note Digital 1 O Line A4 ACH2 65 Digital 1 O Line A5 ACH10 31 1 gj p Q Fa p e Pa r i in p E k 1 Da y E r x n 1 7 b bl uk 1 a My pa i L a Ar i 3 7 LA j A y d k L ni j Ay LA V 4 dg i a Ci n p k e u to m Oo Note 1 gt O es gt m UT N gt N m N 3 D e U Oje gt u O gt 6 7 Digital 170 Line A6 AGND AnalogCom note Digital 1 O Line A7 ACH3 Analog Input Digital I O Line BO Digital I O Line B1 Digital I O Line B2 Digital I O Line B3 Digital I O Line B4 Digital I O Line B5 Digital I O Line B6 Digital I O Line B7 Digital I O Line CO Digital I O Line Cl Digital I O Line C2 Digital I O Line C3 Digital I O Line C4 Digital I O Line C5 Digital I O Line C6 Digital I O Line C7 3 ACH11 Analog Input CH 11 6 m D 3 Note 2 UJ m UJ N m UJ 2 ACH12 Analog Input CH 12 6 AGND AnalogCom note2 ACH5 Analog Input 0 8 ACH13 Analog Input CH 13 26 5 8 UJ Ul UJ m m N Note 1 Digital Common Pins on the SCSI III connector are 35 36 and 40 Note 2 Analog Common Pins on the SCSI III connector are 24 27 29 32 56 59 64 and 67 SOSH nj pJUJN IN D N O C TTLTRG GND Digital Common CNTO Counter Inp
30. 4 Model 2000 E v The serial number is shown for reference only When you have multiple boards device name is matched to a particular board by physical slot not by serial number Device Resources Accessing the DaqBoard 2000 Properties Tab IG 4 DaqBoard 2000c Series Installation Guide 979294 1061 0940 rev 4 0 1 Run the Daq Configuration control panel applet Navigation from the desktop to the applet is as follows Start gt Settings gt Control Panel gt Daq Configuration double click 2 Double click on the Device Inventory s DaqBoard2K0 icon The DaqBoard 2000 Properties tab used for the entire DaqBoard 2000 Series will appear If the DaqBoard2K0 icon is not present skip to the Using Add Device section provided below 3 Enter a Device Name in the text box or use the default DaqBoard2K0 Device Name is for identifying the specific DaqBoard 2000 Series board Note that Device Name actually refers to the PCI slot and not to the actual board 4 Verify that the Device Type shows the correct DaqBoard 2000 Series board e g DaqBoard 2000 DaqBoard 2001 etc Note that available device types can be viewed via the pull down list 5 Confirm that the DaqBoard 2000 Series text box shows a Bus Slot and Serial Number If this text box is empty use its pull down list and select the serial number that matches the one for your board Refer to the inside front cover page for serial
31. BK200 Series adapter boards that were discussed in the first part of this chapter P1 P2 and P3 are subset connectors of the 100 pin P4 connector found on the DaqBoard 2000 Series and 2000c Series boards and for that reason P4 pin correlation is provided Do not confuse connectors Ensure that you only connect P1 I Os to P1 _ P2 TOs to P2 and P3 I Os to P3 Improper connection may result in equipment NX damage Note In the pinouts that follow some pins are irrelevant to certain DaqBoards For example DaqBoard 2002 2002c 12004 and 2004c have no P1 correlation and for those boards P1 and the associated P4 pins should be ignored The DaqBoard 2003 and 2003c only relate to P3 and the associated P4 pins but for these two boards a DBK205 screw terminal adapter is typically used see page 3 3 Note that chapter 1 Device Systems and Device Overviews contains detailed information that is specific to each board 3 8 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User s Manual P1 for DaqBoard 2000 Series and 2000c Series Boards Analog I O it LESE The P1 DB37 connector is SIT I SSeS obtained with the use of PIPL OE LOS amp one of the following SIF SPFIAEF i DBK200 DBK201 DBK202 DBK203 i The PI DB37 connector DBK207 does not apply to DBK205 DBK207 CJC or to DBK208 DBK209 Ea Signal Name Description for P1 Pin Use Correlation 6 Expansion6 Digital OUT external GAIN select b
32. Board 2002 Digital on 40 Digital 4 Counter 2 Timer I O Inputs Outputs DaqBoard 2002 and 2002c are high speed multi function plug and play data acquisition boards for PCI and compact PCI bus computers respectively They feature digital calibration bus mastering DMA 40 digital I O lines four counters and two timers Up to 470 channels of analog and digital I O can be accessed with one board Up to four boards can be installed into a PC A 100 pin connector on the boards provides access to all of the input and output signals The boards accommodate all I O with one cable and one PCI or compact PCI slot The 100 pin I O connector P4 is logically divided into three ports e P1 Not used by DaqBoard 2002 e P2 General purpose digital I O port with 24 lines or digital I O expansion port controlling up to 192 external lines e P3 16 bit digital I O port counter inputs timer outputs and analog outputs The on board scan sequencer lets you select up to 512 channel range combinations The sequencer scans all channels of the scan at 5 us channel or 10 us channel Bus mastering allows digital counter input data and digital output data to flow between the PC and the DaqBoard 2002 board without consuming CPU time DaqBoard 2002 supports a complement of trigger modes including e Digital and pattern triggering The boards have separate digital trigger input line allowing TTL level triggering and latencies less than
33. Both boards support Software based triggering In Software based triggering the PC detects the trigger event from the readings Six pre and post triggering modes are supported DBK205 SIGNAL NO Terminations DAC OUT BE v ee Pa TB1 1 AGND e s j 2 System i C TB1 3 AGND TB1 4 DACI F F 100 kHz nd TB 1 5 AGND 4 Output Configurable TB1 6 DAC2 F Clock PLD EEPROM TB1 7 AGND TB1 8 DAC3 TB1 9 AGND F TB1 10 XTTL TB1 11 CLK E TB1 12 DGND p s s 32 bit Data and al 5 a Address Bus DBK205 Adapter DaqBoard 2003 Block Diagram Note DaqBoard 2003 and DaqBoard 2003c are shipped with one DBK205 adapter The adapter has twelve screw terminals as follows DACO DAC1 DAC2 DAC3 1 digital ground 5 analog grounds 1 external clock CLK and 1 external trigger XTTL DBK205 connects directly to DaqBoard 2003 s P4 connector Connections Installation Reference Note For the DaqBoard 2003 and DaqBoard 2003c installation procedure refer to either the DaqBoard 1000 and 2000 Series Installation Guide or to the DaqBoard 2000c Series Installation Guide as applicable The guides are included at the beginning of this manual VO Connector Analog output signals are available at the board s 100 pin P4 connector A 3 foot 100 conductor ribbon cable part number CA 195 mates with connector P4 however a DBK205 adapter board is included for connecting the 100 pins of P4 to a terminal block
34. DaqView out of the box software provides a graphical user interface with easy to read spreadsheet formats for viewing channel data as well as a choice of analog digital and bar graph meters Waveform analysis can be performed when applicable A product support option included on the data acquisition CD provides a means of performing post data analysis More information is included in the software specific PDF documents that are installed on your hard drive as a part of product support In addition to the included out of the box software Daq products can be controlled via user written custom programs through Applications Program Interface API Several languages are supported including C C and VisualBASIC DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 1 Reference Note Programming topics are covered in the Programmer s User Manual p n 1008 0901 As a part of product support this manual is automatically loaded onto your hard drive during software installation The default location is the Programs group which can be accessed through the Windows Desktop Daq Data Acquisition Devices Category i DaqBook Portable Data Acquisition Modules Primary 12 bit DaqBook 100 112 120 Acquisition 16 bit DaqBook 200 216 260 2001 2005 2020 Device DaqBoard 1000 Plug In Boards for PCI Bus Slots Series 16 bit 200 kHz 2 boards identified as 11000 and 11005 Make use of a 68 pin SCS
35. Guard for DBK5 DBK8 and DBK44 e Applicable cables and connectors CE Cable Kits for DaqBoard 2000 Series and 2000c Series Boards Turn OFF the power to and UNPLUG the host PC and externally connected equipment prior to removing the PC s cover and removing or installing the DaqBoard 2000 Series or 2000c Series Board Electric shock or damage to equipment can result even under low voltage conditions Take ESD precautions packaging proper handling grounded wrist strap etc Use care to avoid touching board surfaces and onboard components Only handle boards by their edges or ORBs if applicable Ensure boards do not come into contact with foreign elements such as oils water and industrial particulate Note The CE Cable Kit used with DaqBoard 2000 Series Boards is pin CA 209 The CE Cable Kit used with cPCI DaqBoard 2000c Series Boards is p n CA 209c By following these instructions correctly your DaqBoard 2000 Series or 2000c Series Board will be CE Compliant in accordance with the conditions stated on your board s Declaration of Conformity If your board is already installed you will need to remove it from the PC before proceeding If your board is not yet installed proceed to the section entitled Install the CE ORB Remove DaqBoard 2000 Series or 2000c Series Board from the Host PC For DaqBoard 2000 Series Boards PCI type 1 Turn the host PC s power OFF 2 Turn power OFF to externally connected equi
36. I III connector The DaqBoard 1000 Series boards do not support DBK options DaqBoard 2000 Plug In Boards for PCI Bus Slots Series 16 bit 200 kHz Six boards identified as 2000 through 12005 Make use of a 100 pin connector P4 DaqBoard 2000c Plug In Boards for Compact PCI Bus Slots Series 16 bit 200 kHz Six boards identified as 2000c through 2005c Make use of a 100 pin connector P4 Unless otherwise specified documentation discussing a DaqBoard 2000 series board also applies to a DaqBoard 2000c Series board DaqBoard ISA types Plug In Boards for ISA Bus Slots 12 bit DaqBoard 100A 112A 16 bit DaqBoard 200A 216A 2000 Daq PC Card Plug In PCMCI Card 12 bit Daq 112B 16 bit Daq 216B i Analog Signal Cards and modules used to condition Analog Signals DBK Option Conditioning DBK 4 7 8 9 12 13 15 17 18 19 42 43A 44 45 50 51 52 53 54 Caros ana 55 65 80 81 82 83 84 85 90 100 207 207 CJC DBK 2 5 DBK 20 21 23 24 25 208 210 Expansion Cards and modules used to expand the acquisition system Connections DBK 1 10 11A 35 40 41 60 200 201 202 203 204 205 206 209 Power Supply DBKs 30A 32A 33 34 Included Software DaqView Post Data Acquisition Analysis Program actual application not specified Visual Basic extensions Application Programming Interface API Optional Software DaqView 2000 DaqViewXL DASYLab DBK Option cards and modules are not supported by DaqBoa
37. I III connector Chapter 2 includes a pinout The following cable and terminal board options can be used to provide convenient screw terminal connections for all signal I O lines Mating Cable The CA G56 is a 68 conductor shielded cable It is used to connect a DaqBoard 1000 Series board to a TB 100 termination board The cable length is 3 feet TB 100 TB 100 is an optional termination board It provides convenient screw terminal connections for all signal I O lines of a DaqBoard 1000 Series board Reference Note Daq Systems and Device Overviews 889094 The TB 100 terminal board connection option is discussed in chapter 2 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 2000 Digital on 16 Analog 2 Analog 40 Digital 4 Counter 2 Timer Input Output I O Inputs Outputs DaqBoard 2000 and DaqBoard 2000c are high speed multi function plug and play data acquisition boards for PCI and compact PCI bus computers respectively They feature a 16 bit 200 kHz A D converter digital calibration bus mastering DMA two 16 bit 100 kHz D A converters 40 digital I O lines four counters and two timers Up to 470 channels of analog and digital I O can be accessed with one DaqBoard 2000 Up to four boards can be installed into a PC A 100 pin connector on the boards provides access to all of the input and output signals The DaqBoard 2000 and 2000c accommodate all I O with one cable and one PCI or compact PCI
38. I is suitable for ANALOG IO DBK200 does not support Digital I O or frequency signals DBK200 s P4 100 pin connector connects to the DaqBoard 2000 Series or DaqBoard 2000c Series board s P4 connector via a CA 195 Cable DBK200 Adapter with PI 3 2 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User s Manual DBK201 The DBK201 P4 to P1 P2 P3 adapter provides DB37 P1 P2 and P3 connectors e Pl is used for ANALOG I O e P2is used for DIGITAL I O e P31s used for Pulse Frequency Digital and Counter Timer I O DBK201 s P4 100 pin connector connects to a DaqBoard 2000 Series or 2000c Series board s P4 connector via a CA 195 Cable DBK201 P4 to P1 P2 P3 Adapter DBK202 DBK203 and DBK204 DBK202 DBK203 with Cover Plate Removed P4 to P1 P2 P3 Adapter with Screw Terminals Chassis Mounted P4 to P1 P2 P3 Adapter with and Locators for RC Filter Setup Screw Terminals and Locators for RC Filter Setup Note The DBK203 DBK204 and DBK204c modules are identical The DBK204 designation indicates that the module includes a CE cable kit for use with DaqBoard 2000 Series boards that are of the standard PCI type The DBK204c designation indicates that the module includes a CE cable kit for use with the compact PCI type boards 1 e the DaqBoard 2000c Series The DBK202 DBK203 DBK204 and DBK204c adapters each provide a DB37 P1 connector DB37 P2 connector and a 40 pin header designated
39. Range Anywhere within range of the selected input channel Trigger level Programmable 11 bit resolution including window triggering Hysteresis Programmable 11 bit resolution Latency 5 us maximum 2 Single Channel Analog Software Trigger Any analog input channel including any of the 256 analog expansion channels can be selected as the software trigger channel If the trigger channel involves a calculation such as with temperature then the driver automatically compensates for the delay required to calculate the reading resulting in a maximum latency of one scan period Input Signal Range Anywhere within the range of the selected trigger channel Trigger level Programmable 16 bit resolution including window triggering Latency One scan period maximum 3 Single Channel Digital Trigger A separate digital input is provided for digital triggering Input Signal Range 15V to 15V Trigger level TTL Minimum pulse width 50 ns high 50 ns low Latency 5 us maximum Note Specifications subject to change without notice 889094 Specifications DaqBoard 2000 Series 7 3 4 Digital Pattern Triggering 8 or 16 bit pattern triggering on any of the digital input ports Programmable for trigger on equal above below or within or outside of a window Individual bits can be masked for don t care condition Latency One scan period maximum 5 Counter Totalizer Triggering Counter totalizer inputs can trigger an acquisitio
40. Series Boards Warm up 1 hour to rated specifications Supply voltage range 4 75 VDC to 5 25 VDC PCI bus Power consumption per board 3 5 W up to 10 W with external accessories Power Available for External Signal Conditioning and Expansion Options 5 Vat 1 A all boards 15 Vat 75 mA each with exception of DaqBoard 2002 Operating temperature 0 to 60 C Storage temperature 40 to 80 C Relative Humidity 0 to 95 non condensing Vibration MIL Std 810E Dimensions DaqBoard 2000 Series 165 mm W x 15 mm D x 108 mm H 6 5 x 0 6 x 4 2 DaqBoard 2000c Series 160mm W x 19 mm D x 100 mm H 6 3 x 0 7 x 3 9 Weight DaqBoard 2000 Series 160 g 0 35 Ibs DaqBoard 2000c Series 178 95 g 0 39 Ibs Note Specifications subject to change without notice 889094 Specifications DaqBoard 2000 Series 7 1 Analog Specifications Applicable to DaqBoard 2000 2001 2005 A D Successive approximation 200 kHz maximum conversion rate Resolution 16 bits Channels 16 single ended or 8 differential expandable up to 256 differential Conversion Time 5 us Connector 100 pin high density edge type Missing Codes None over full operating temperature range Input Voltage Ranges software programmable via sequencer Accuracy Note 2 Input Noise Notes One Year LSB rms 1 Specifications assume Voltage Range 0 to 35 C 10 Hz 200 kHz differential input single AN channel scan 200 kHz reading range Note 3 scan ra
41. VO Converters DENS SE P Analog Input pac our few 16 bit 200 kHz N ANALOG IN HER Gain amp Offset Analog to Digital s Amplitier Converter E ANALOG DE CONTROL FE t 512 step T Random Access 44 Channel Gain 22 Sequencer DIGITAL FE CONTROL PE T as Programmable s Sequences DIGITAL UO oere heute Configurable 32 bit Data and PLO EEPROM Address Bus DaqBoard 2001 Block Diagram The DaqBoard 2001c Block Diagram is the same with exception that the 2001c board uses a compact PCI Bus instead of a standard PCI bus Connections Installation GN Reference Note For the DaqBoard 2001 and 12001c installation procedure refer to either the DaqBoard 1000 and 2000 Series Installation Guide or to the DaqBoard 2000c Series Installation Guide as applicable The guides are included at the beginning of this manual VO Connector All input and output signals are available at the board s 100 pin P4 connector A 3 foot 100 conductor ribbon cable part number CA 195 mates with connector P4 Reference Note There are several P4 connector board options available for connecting the 100 pins of P4 to typical DB37 connectors P1 P2 and P3 In addition to being briefly discussed in chapter 3 of this manual these options referred to as DBK200 Series are detailed in the DBK Cards and Modules User s Manual p n 457 0905 1 14 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual Daq
42. able for both analog and digital expansion The board provides three DB37 connectors P1 P2 and P3 DBK209 connects to DaqBoard 2000 Series or 2000c Series P4 connector via a CA 195 cable Other than the form factor DBK209 is identical to DBK201 e PI is used for ANALOG I O e P2 is used for DIGITAL I O e P3is used for Pulse Frequency Digital and Counter Timer I O DBK209 DBK209 s P4 100 pin connector connects to the P4 to P1 P2 P3 Mini adapter Board DaqBoard 2000 Series or 2000c Series board s P4 connector via a CA 195 Cable DBK210 DBK210 is a four bank carrier board for optically isolated Grayhill 7OM Series mini modules Each bank supports up to eight digital I O modules Each bank can be independently set to input or output The settings are made via micro switches The Grayhill 70M Series I O modules are industry standard 5 volt logic level modules DBK210 boards are typically installed in NEMA type panels however they can be installed on DIN rails Separate mounting instructions are included with Rack Mount Kit part no Rack DBK 3 and with DIN rail Mount Kit part no DIN DBK 1 DBK210 boards contain three DB37 connectors as follows two P2 connectors for daisy chaining to other DBK210s or to other P2 supported devices one PI connector for convenient access to the analog input channels of a DaqBook 2000 Series or a DaqBoard 2000 Series device mi sti P 2 ee ee ee gg Er FR et d
43. ailable at the board s 100 pin P4 connector A 3 foot 100 conductor ribbon cable part number CA 195 mates with connector P4 Reference Note There are several P4 connector board options available for connecting the 100 pins of P4 to typical DB37 connectors P1 P2 and P3 In addition to being briefly discussed in chapter 3 of this manual these options referred to as DBK200 Series are detailed in the DBK Cards and Modules User s Manual p n 457 0905 1 20 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 2005 Digital v r on 16 Analog 40 Digital 4 Counter 2 Timer Outputs Input I O Inputs DaqBoard 2005 and DaqBoard 2005c are high speed multi function plug and play data acquisition boards for PCI and compact PCI bus computers respectively They feature a 16 bit 200 kHz A D converter digital calibration bus mastering DMA 40 digital I O lines four counters and two timers Up to 470 channels of analog and digital I O can be accessed with one board Up to four boards can be installed in one PC A 100 pin connector on the board provides access to all of the input and output signals The Each board accommodates all I O with one cable and one PCI or compact PCI bus slot as applicable The 100 pin I O connector P4 is logically divided into three ports e P1 Analog input port for 16 single ended or 8 differential analog inputs with 13 software programmable range
44. alog input modules The DBK207 board includes two P1 connectors for analog expansion a power connection terminal and 16 signal terminal blocks DBK207 CJC Carrier board for 5B compatible analog input modules The DBK207 board includes two P1 connectors for analog expansion a power connection terminal 16 signal terminal blocks and cold junction sensors for cold junction compensation CJC for thermocouple applications DBK208 Carrier board for Opto 22 compatible solid state relay SSR digital modules The DBK208 board includes two P2 connectors for digital expansion a power connection terminal and 16 signal terminal blocks DBK209 mini adapter board suitable for both analog and digital expansion The board provides three DB37 connectors P1 P2 and P3 DBK210 32 channel digital I O carrier board The DBK210 provides two P2 connectors one P1 connector footprints for 32 optically isolated Grayhill 7OM Series mini modules a 100 pin P4 connector and 4 removable screw terminal blocks Each block supports 8 mini modules DIN DBK 1 DIN rail mount kit for DBK206 DBK207 and DBK208 applications Rack DBK 3 Rack mount kit for DBK206 DBK207 DBK208 and DBK209 applications Manuals Manual Set Set 1033 p n 1033 0900 This is a hardcopy set of manuals that is available for purchase The set includes the following three manuals DaqBoard 1000 and 12000 Series User s Manual p n 1033 0901 Programmer s Manual
45. and start up the PC Note At this point some PCs may prompt you to insert an IG 4 installation disk While this is rare if you do receive such a prompt simply place the install CD ROM into the disk drive and follow additional screen prompts DaqBoard 1000 and 2000 Series Installation Guide 898195 7 Align Groove in Edge Connector 9 Replace Screw 8 Push Board ff Firmly into PCI Slot Installing a DaqBoard 2000 Series Board 1033 0940 rev 8 0 1033 0940 rev 8 0 898195 Step 3 Configure Boards DaqBoard 1000 and 2000 Series Boards have no jumpers or switches to set Configuration is performed in its entirety through software Refer to the following figure and steps to complete the configuration The numbers in the figure correspond to the numbered steps immediately following the figure Address E Control Panel E Add New Hardware E Add Remove Programs Daq Configuration Urii Daq Driver ga Core nak ae Configuration Utility Dag Configuration s ar y Daq Configuration Device Inventory Computer E s DaqBoard2K0 2 SF DaqBookO ax eVO Properties Add Device Close 3 4 Daq Configuration DaqBoard 2000 Properties Test Hardware Device Settings Device Name JDaqBoardzkd 3 DaqBoard 2000 Series Hardware Bus 0 Slot 12 S N 182814 Model 2000 E v The serial number is shown for reference only When you
46. aqBoard 2000 Series 7 5 Optional Accessories for DaqBoard 2000 Series Software DaqView including drivers for DasyLab and LabView eZ PostView post acquisition software DasyLab Hardware CA 37 x Expansion cable The x indicates number of devices on expansion side for example CA 37 1 is a DB37 to DB37 cable that provides expansion to 1 card CA 37 cables are used to connect from P1 to P1 P2 to P2 or P3 to P3 CA 195 Interconnect cable 3 ft 100 conductor mates with all above options and with DaqBoard 2000 Series P4 connectors DBK200 Adapter panel for connection of DBK signal conditioning and expansion options analog DBK201 Adapter panel connects DBK signal conditioning and expansion options DBK202 Adapter panel with screw terminals connects DBK signal conditioning and expansion options DBK203 Adapter module with screw terminals connects DBK signal conditioning and expansion options DBK204 Consists of a DBK203 and a CA 209 CE cable kit for meeting CE compliance DBK205 This adapter provides screw terminal access to DaqBoard 2003 s and DaqBoard 2003c s four analog outputs DACO DAC1 DAC2 and DAC3 1 digital ground 5 analog grounds an external clock CLK and an external trigger XTTL DBK206 Screw terminal board suitable for both analog and digital expansion It provides three DB37 connectors P1 P2 and P3 and corresponding terminal blocks DBK207 Carrier board for 5B compatible an
47. are used e The host computer and all connected equipment must be CE compliant e All power must be off to the device and externally connected equipment before internal access to the device is permitted e Isolation voltage ratings do not exceed documented voltage limits for power and signal inputs All wire insulation and terminal blocks in the system must be rated for the isolation voltage in use Voltages above 30 Vrms or 60 VDC must not be applied if any condensation has formed on the device e Current and power use must not exceed specifications Do not defeat fuses or other over current protection Emissions Immunity Conditions 4 2 The specific immunity conditions for CE compliance vary by product but general immunity conditions include e Cables must be shielded braid type with metal shelled connectors Input terminal connections are to be made with shielded wire The shield should be connected to the chassis ground with the hardware provided e The host computer must be properly grounded e In low level analog applications some inaccuracy is to be expected when I O leads are exposed to RF fields or transients over 3 or 10 V m as noted on the Declaration of Conformity CE Compliance 959495 DaqBoard 1000 and 2000 Series User s Manual CE Enhancements for DBKs The following CE enhancements are described in the individual document modules of the DBK Cards and Modules User s Manual p n 457 0905 e DBK41 CE e Edge
48. as P3 e Pl is used for ANALOG I O e P2 for DIGITAL I O e P3 for Pulse Frequency Digital and Counter Timer I O In addition to the P1 P2 and P3 connectors these boards include terminal blocks designated TB1 through TB12 The blocks provide a screw terminal connection option for P1 P2 and P3 Each of the three adapters can be connected to the DaqBoard 2000 Series or 2000c Series 100 pin P4 connector via a CA 195 cable Note These screw terminal adapter boards provide a means of connecting signals to a DaqBoard 2000 Series or a 2000c Series board through one of three methods e Cables connected to P1 P2 and P3 connectors as applicable e Signal wires connected to the appropriate screw terminal blocks TB1 through TB12 The board s silkscreen identifies all screw terminals e With a combination of the above two methods Note Board images are not to the same scale DaqBoard 1000 and 2000 User s Manual 898195 Connections amp Pinouts DaqBoard 2000 Series 3 3 DBK205 The DBK205 provides 12 screw terminal connections on one terminal block TB1 for DaqBoard 2003 and DaqBoard 2003c The signal lines on DBK205 s P4 connector correspond with P3 associated pins on the P4 connector of DaqBoard 2003 and 2003c The DBK205 can connect directly to the 100 pin P4 connector on the DaqBoard 2003 or DaqBoard 2003c SIGNAL VO DBK205 P Terminations DBK205 DAC OUT F TB1 1 AGND E Z an mi2 bach FEN En TB1 3 AGND
49. ate divided by 1 to 65535 programmable High level output voltage 2 0 V minimum 3 75 mA 3 0 V minimum 2 5 mA Low level output voltage 0 4 V maximum 2 5 mA Frequency Pulse Counters Applicable to DaqBoard 2000 12001 12002 12004 12005 Counter inputs can be scanned synchronously along vvith analog and digital scanned inputs based either on internal programmable timer or an external clock source Bus mastering DMA provides CPU and system independent data transfers insuring data acquisition performance irrespective of other system activities Counters can be configured to clear when read or to totalize and clear under program control Channels 4 x 16 bit cascadable as 2 x 32 bit Input rate 10 MHz maximum Input Signal Range 15 V to 15 V Input Characteristics 2 7 kQ series in parallel with 20 pF to common and 10 kQ to 5 V Input protection 8 kV ESD clamp diodes parallel Trigger Level TTL Minimum pulse width 50 ns high 50 ns low Included Accessories and Software for DaqBoard 2000 Series Software Windows Drivers 32 bit 90 day Getting Started DaqView Hardware DBK205 is included with only DaqBoard 2003 and DaqBoard 2003c This adapter option provides screw terminal access to the board s four analog outputs DACO DAC1 DAC2 and DAG3 1 digital ground 5 analog grounds an external clock CLK and an external trigger XTTL Note Specifications subject to change without notice 889094 Specifications D
50. atures a 16 bit 200 kHz A D converter digital calibration bus mastering DMA two 16 bit 100 kHz D A converters 24 digital I O lines four counters and two timers Up to four boards can be installed into a PC One 68 pin SCSI III connector on the board provides access to all of the input and output signals The DaqBoard 1000 accommodates all I O with one cable and one PCI slot The 68 pin I O connector is logically divided into three functions e Analog input forl6 single ended or 8 differential analog inputs with 7 software programmable bipolar ranges 10 V to 156 mV full scale e 24 lines of general purpose digital I O e 4 counter inputs 2 timer outputs and 2 analog outputs The on board scan sequencer lets you select up to 512 channel range combinations The sequencer scans all channels of the scan at 5us or 10 us channel Bus mastering allows analog and digital counter input data as well as analog and digital output data to flow between the PC and the DaqBoard without consuming CPU time DaqBoard 1000 supports trigger modes that include e Digital and pattern triggering The boards have separate digital trigger input line allowing TTL level triggering and latencies less than 5 us The trigger can be programmed for logic level or edge triggering In pattern triggering any of the digital input ports acts as the trigger port You can program the digital pattern e Software based triggering The PC detects the trigg
51. b at http www daqboard com and in your DBK Option Cards and Modules User s Manual p n 457 0905 After the install you can navigate to the DBK manual and other relevant electronic documents from your desktop as follows Start gt Programs gt IOtech DaqX Software gt DaqBoard 2000 Series Users Minimum System Requirements Reference Note Adobe PDF versions of user manuals will PC system with Pentium Processor automatically install onto your hard drive as a part of product Windows Operating System support The default location is in the Programs group which RAM as follows can be accessed from the Windows Desktop Refer to the PDF 32 Mbytes of RAM for Windows 95 98 NT documentation for details regarding both hardware and 64 Mbytes of RAM for Windows Me software Note that hardcopy versions of the manuals can be O ME ES ad ordered from the factory 64 Mbytes of RAM for Windows XP Step 1 Install Software IMPORTANT Software must be installed before installing hardware 1 Remove previous version Daq drivers if present You can do this through Microsoft s Add Remove Programs feature 2 Place the Data Acquisition CD into the CD ROM drive Wait for PC to auto run the CD This may take a few moments depending on your PC If the CD does not auto run use the Desktop s Start Run Browse feature 3 After the intro screen appears follow the screen prompts Upon completing the software installation continue with s
52. c DBK cards and Cees ye modules which can be used with DaqBoard 2000 Test Hardware Tab systems Condensed Screen Image Note If you experience difficulties please consult your user documentation included on your CD before calling for technical support Note that the user documentation At this point we are ready to connect signals e For DaqBoard 2000 Series boards signal connection is typically accomplished with the use of a DBK200 Series option e For DaqBoard 1000 Series boards connection is typically made via a terminal board such as the optional TB 100 Reference Notes gt DagqBoard 2000 Series users For detailed information regarding the DBK200 Series options refer to the DBK Option Cards and Modules User s Manual p n 457 0905 gt During software installation Adobe PDF versions of user manuals are automatically installed onto your hard drive as a part of product support The default location is in the Programs group which can be accessed from the Windows Desktop A copy of the Adobe Acrobat Reader is included on your CD The Reader provides a means of reading and printing the PDF documents Note that hardcopy versions of manuals can be ordered from the factory IG 6 DaqBoard 1000 and 12000 Series Installation Guide 898195 1033 0940 rev 8 0 DaqBoard 2000c Series Installation 2001 through 2004 by This guide tells you how to complete the following steps for a successful installation S
53. cable to an On Board 40 pin header Note 3 Pins 31 32 33 and 34 on the P3 DB37 connector are used for Analog Out DACs DaqBoard 2001 2003 amp 2004 can utilize all four pins DaqBoard 2000 does not make use of pins 31 or 32 DaqBoard 2002 and DaqBoard 2005 boards do not make use of pins 31 through 34 as these series two boards have no Analog Out DAC DaqBoard 1000 and 2000 User s Manual 898195 Connections amp Pinouts DaqBoard 2000 Series 3 11 P4 to P1 P2 and P3 Correlation The following table lists the correlation between the P4 I O lines and their respective P1 P2 and P3 pin locations on the DBK200 Series boards Ground correlation is provided in a subsequent table P1 pin 1 P2 pin 18 20 P3 pin 20 B1 Power Expansion 5 Volts P1 pin 1 P2 pin 18 20 P3 pin 20 P2 expansion Data bit 15 P2 expansion Data bit 14 P2 expansion Data bit 13 P2 expansion Data bit 11 P2 expansion Data bit 10 P2 expansion Data bit 9 P2 expansion Data bit 8 P2 expansion Data bit 7 P2 expansion Data bit 6 P2 expansion Data bit 5 P2 expansion Data bit 4 P2 expansion Data bit 3 B3 Port A bit 4 Dig I O P2 Digital Port A bit 4 or P2 pin 33 P2 expansion Data bit 12 Port C bit 0 Dig I O P2 Digital Port C bit 0 or P2 pin 29 P2 expansion Data bit 0 Ground Dig I O Digital Common See Ground Tables Port B bit 7 Dig I O P2 Digital Port B bit 7 or P2 pin 3 P2 expansion address bit 0 B8 Port C bit 2 Dig I O P2 Digital Port C b
54. calibrated However if adjustments are needed they should be completed in the following order L PGA Input and Output Offset 2 Sample Hold Offset 3 A D Offset and Gain 4 VDC Voltage Reference Da DACO Full Scale 6 DACI Full Scale 7 DAC2 Full Scale 8 DAC3 Full Scale In regard to the various DaqBoard 1000 and 12000 Series boards DAC applicability is as follows DaqBoard 1000 DACO and DACI apply DaqBoard 1005 No DACs apply DaqBoard 2000 and 2000c DACO and DACI apply DaqBoard 2001 and 2001c DACO DACI DAC2 and DAC3 apply DaqBoard 2002 and 2002c No DACs apply DaqBoard 2003 and 2003c DACO DACI DAC2 and DAC3 apply DaqBoard 2004 and 2004c DACO DACI DAC2 and DAC3 apply DaqBoard 2005 and 2005c No DACs apply A Windows based program DaqCal exe is used to calibrate Daq systems including analog expansion cards DaqCal exe is used in conjunction with e a 4 5 digit digital multi meter e an adjustable voltage calibrator e an ambient temperature meter To use the calibration program 1 Launch DaqCal Note DaqCal is installed automatically from your data acquisition CD as a part of product support This takes place during software installation DaqCal s default location is the IOtech DaqX Software folder in the Programs group 2 When DaqCal opens you will be prompted to select your device from a list After doing so simply follow the illustrated on screen instructions DaqBoard 1000
55. clude e 40 TTL level digital I O lines They are divided into three 8 bit ports and one 16 bit port e Four 16 bit counters Each can accept frequency inputs up to 10 MHz The counters can be cascaded into two 32 bit counters e Two 16 bit timer outputs Each can generate square waves from 16 Hz to 1 MHz e Configuration through software There are no switches or jumpers on a DaqBoard 2005 DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 21 SIGNAL V 8 DENS SE Analog Input PGA 3 ga x1 24 8 l Input Protection mi sain amp Offset 18 bit 200 kHz P Et ao ANALOG IN 3 Analog to Digital naogopa s x16 32 54 Amplifier Canvertar ad i 8 Four External Ch Select ANALOG PFS Two External Gain Select CONTROL PES One SS amp H 1 s External 512 step E oo Din TTL Trigger Input MUA Control Random Access FE pj Pone Analog In Pacer Clock ChannevGain d Sequencer E FIFO DIGITAL FER Four 16 bit Counter Inputs I Data CONTROL H Two 16 bit Timer Outputs Sequencer Reset Bu umer k s d Proorammable Dual 11 bit m andet Trigger DACs i l d Timebase DIGITAL VO 5 ps to amp hours F oo J System L PEI Controller j Controller Configurable Configurable 32 bit Data and FLD EEPROM Address Bus DaqBoar
56. counter Six pre and post triggering modes are supported The two 16 bit 100 kHz analog output channels have an output from 10 V to 10 V These channels are separate from the D As used to determine analog trigger levels Using Bus Mastering DMA each D A can output a waveform Bus Mastering DMA also allows for digital pattern generation on the 16 bit high speed digital I O port Other features of the DaqBoard 2000 include e 40 TTL level digital I O lines They are divided into three 8 bit ports and one 16 bit port e Four 16 bit counters Each can accept frequency inputs up to 10 MHz The counters can be cascaded into two 32 bit counters e Two 16 bit timer outputs Each can generate square waves from 16 Hz to 1 MHz e Configuration through software There are no switches or jumpers on the DaqBoard 2000 DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 11 Two 16 bit Digital to Analog SIGNAL 110 Converters DAC OUT ANALOG IN Four External Ch Select ST External Gain Select One 5584H ANALOG CONTROL DIGITAL CONTROL DIGITAL VO a T ED DD RN Ae oR WN he ha FM 8 DEMS SE Analog input PGA mi x1 2 4 8 x16 32 64 16 bit 200 kHz Sy Anakog to Digital Converter i I Gan amp Offset Amplifier kHz 512 step Random Access ChannelGain Sequencer Programmable Sequences Timebasa 5 pus to 6 hours System
57. crew terminals for accessing all I O for one DaqBoard 1000 or DaqBoard 1005 The terminal board connects to the DaqBoard 1000 Series board s 68 pin connector via a CA G56 cable Rack Mount Kit Rack3 This is a kit for mounting the TB 100 termination board to a rack 68 Conductor Cable CA G56 68 conductor 3 ft shielded cable Used to connect a TB 100 terminal board to a DaqBoard 1000 or a DaqBoard 1005 Manual Set Set 1033 p n 1033 0900 This is a hardcopy set of the following 3 manuals available for purchase o DagBoard 1000 and 2000 Series User s Manual p n 1033 0901 o Programmers Manual for developing custom programs using API commands p n 1008 0901 o DBK Option Cards amp Modules User s Manual p n 457 0905 Note DaqBoard 1000 Series boards do not support DBK options Software Applicable to DaqBoard 1000 1005 DaqView for setup data acquisition display and analysis DaqViewXL for seamless execution within Microsoft Excel s tool palette eZ PostView for post acquisition viewing and analysis 6 4 Specifications DaqBoard 1000 Series 889094 Note Specifications subject to change without notice Specifications DaqBoard 2000 Series Boards 7 I O Comparison Matrix for DaqBoard 2000 Series Boards DaqBoard Analog Input Analog Output Digital I O Counter Timer Identity Channels Channels Channels Inputs Outputs Dac 2 g E KE Le Le General Specifications Applicable to all DaqBoard 2000
58. ct of the bodies or when induced by an electrostatic field ESD energy can damage an integrated circuit IC Some transducers e g strain gages thermistors and resistance temperature detectors RTDs require a known voltage or current Typically the variation of this signal through the transducer corresponds to the condition measured The degree to which an input signal is amplified or attenuated to allow greater accuracy and resolution can be expressed as xn or dB The arrangement or operation of a circuit so that signals from another circuit or device do not affect the isolated circuit In reference to Daq devices isolation usually refers to a separation of the direct link between the signal source and the analog to digital converter ADC Isolation is necessary when measuring high common mode voltage Some transducers produce a voltage in linear proportion to the condition measured Other transducers e g thermocouples have a nonlinear response To convert nonlinear signals into accurate readings requires software to calibrate several points in the range used and then interpolate values between these points A device that collects signals from several inputs and outputs them on a single channel The value of a signal on a channel at an instant in time When triggered the ADC reads the channel and converts the sampled value into a 12 or 16 bit value A series of measurements across a pre selected sequence of channels A
59. cy inputs up to 10 MHz The counters can be cascaded into two 32 bit counters e Two 16 bit timer outputs Each can generate square waves from 16 Hz to I MHz e Configuration through software There are no switches or jumpers on the DaqBoard 1005 DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 9 Signal I O 16 Input o e o o Analog In 2 Protection 8 o e 9 29 o 0 96 0 QO 8 o Analog aa One TTL Tngger Input Control Baja One Analog Input Pacer Clockf _ Digital 2 Four 16 bit Counter Inputs Control pg Two 16 bit Timer Outputs Digital 1 0 68 Pin SCSI III 8 DE 16 SE Analog Input xl 2 4 8 Progiamunab le Gain A mpli fier x16 32 64 16 bit 200 kHz Analog to Digital Converter 512 step Random Access Channel Gain Sequencer sequencer Reset Prog rammable sequencer Tumebase 5 us to 6 hows System Controller Configwable PLD Configurable 32 Bit EEPROM Data and Address Bus DaqBoard 1005 Block Diagram Connector Connections Installation Reference Note VO Connectors For the DaqBoard 1005 installation procedure refer to the DaqBoard 1000 and 2000 Series Installation Guide A copy of the guide is included at the beginning of this manual All input and output signals are available at the board s 68 pin SCS
60. d 2005 Block Diagram The DaqBoard 2005c Block Diagram is the same with exception that the 2005c board uses a compact PCI Bus instead of a standard PCI bus Connections Installation Reference Note For the DaqBoard 2005 and compact PCI DaqBoard 2005c installation procedure refer to either the DaqBoardi 1000 and 2000 Series Installation Guide or to the DaqBoard 2000c Series Installation Guide as applicable The guides are included at the beginning of this manual VO Connector All input and output signals are available at the board s 100 pin P4 connector A 3 foot 100 conductor ribbon cable part number CA 195 mates with connector P4 Reference Note There are several P4 connector board options available for connecting the 100 pins of P4 to typical DB37 connectors P1 P2 and P3 In addition to being briefly discussed in chapter 3 of this manual these options referred to as DBK200 Series are detailed in the DBK Cards and Modules User s Manual p n 457 0905 1 22 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual Using DBK Cards and Modules for Signal Conditioning The DBK signal conditioning cards and module are designed for use with DaqBooks LogBooks and various types of data acquisition boards 1 e ISA PCI and compact PCI types The DBKs perform best when used with an acquisition device that can dynamically select channel gain and range DBK cards and
61. d the maximum update rate of 100kHz Synchronous Output Data Source Associated boards allow the data source for synchronized output operations to be that of a memory based buffer or a file located on a mass storage medium With either type of output data source the output data for all the channels are contained in the buffer and or file The file path may be any file located on the machine or network accessible file Asynchronous I O Operations Associated boards allow asynchronous input of any counter or digital channel that is not currently configured for synchronous acquisition The boards also allow for asynchronous output to any D A channels not currently configured for waveform output In addition for DaqBoard 2000 Series boards the 16 bit P3 digital port can be used for both asynchronous input and output operations if it is not currently configured for streamed pattern output operations Also the timer outputs can be programmed at any time regardless of the current state of synchronous or asynchronous operations on other channels Digital VO Channels Local 8255 Channels The boards which have digital I O capabilities have an implemented Intel 8255 core in the digital I O logic For DaqBoard 2000 Series boards this is applicable to the P2 port see pinouts for P2 to P4 relationship With the Intel 8255 there are three 8 bit wide ports available for I O and one 8 bit wide port for configuration purposes The configuration port is
62. des information regarding eZ FrequencyView and eZ TimeView These two applications have more features than does eZ PostView and are available for purchase They can however be used freely during a 30 day trial period DaqBoard 1000 and 12000 Series User s Manual DBK Options pdf The DBK Option Cards and Modules Manual discusses each of the DBK products available at the time of print The DBK Options document does not apply to PDF DaqBoard 1000 Series boards 457 0905 Programmers Manual pdf The programmer s manual pertains to developing custom programs using Applications Program Interface API commands FE Programmers should check the readme file on the install CD ROM for the location of 1008 0901 program examples included on the CD DaqBoard 1000 and 2000 Series User s Manual vi DaqBoard 1000 and 12000 Series User s Manual Manual Layout DaqBoard 1000 and 12000 Series Installation Guide p n 1033 0940 DaqBoard 2000c Series Installation Guide pin 1061 0940 Chapter 1 Dag Systems and Device Overviews This chapter begins with a discussion of the modular concept that is associated with Daq data acquisition systems The chapter then goes on to provide an overview for each DaqBoard 1000 and 2000 Series board Chapter 2 Connections and Pinouts DaqBoard 1000 Series This chapter includes board pinouts for the DaqBoard 1000 Series 68 pin connector It includes screw terminal identification for TB
63. ditional information regarding your PC and enabling Bus Mastering DMA for PCI slots 1 Turn off power to and UNPLUG the host PC and externally connected equipment 2 Remove the PC s cover Refer to your PC Owner s Manual as needed 3 Choose an available PCI bus slot 4 Carefully remove the DaqBoard from its anti static protective bag If you have not already done so write down the serial number of your board at this time 5 Refer to the figure at the right Remove the screw that 6 Remove Blank secures the blank adapter plate which is associated with the Adapter Plate gt PCI Slots PCI slot you will be using Refer to your PC Owner s Sn Manual if needed 6 Remove the blank adapter plate 5 Remove Screw PC Rear Panel Removing a Blank Adapter Plate 1033 0940 rev 8 0 898195 DaqBoard 1000 and 12000 Series Installation Guide IG 3 7 Refer to the figure at the right Align the groove in the DaqBoard s PCI edge connector with the ridge of the desired PCI slot and with the PC s corresponding rear panel slot 8 Push the board firmly into the PCI slot The board will snap into position 9 Secure the board by inserting the rear panel adapter plate SCrew 10 Using the previous steps install additional boards into available PCI bus slots if applicable to your application 11 Replace the computer s cover 12 Plug in all cords and cables that were removed in step I 13 Apply power to
64. e channels at the same 10 us channel rate as other DBKs 256 scans in 2 56 ms in a full system Each user installed 5B module offers 500 V isolation from the system and between channels Both DBK207 and DBK207 CJC include 16 screw terminal blocks for signal inputs In addition the DBK207 CJC includes cold junction compensators CJCs for use with thermocouple 5B modules Sockets are provided for user installed AC1362 current sense resistor modules as discussed in 5B Module Connection in the DBK207 section of the DBK Option Cards and Modules User s Manual p n 457 0905 DaqBoard 1000 and 2000 User s Manual 898195 Connections amp Pinouts DaqBoard 2000 Series 3 5 DBK208 DBK208 is a two bank carrier board for optically isolated Solid State Relay SSR modules Each bank supports up to eight digital I O modules The banks can be independently set as input or output via jumpers JPO for Bank 0 and JP1 for Bank 1 The I O modules are industry standard Opto 22 compatible 5 volt logic level modules The DBK208 provides e two P2 connectors for DIGITAL I O e footprints for sixteen optically isolated Solid State Relay SSR Modules e 16 dual screw terminal blocks DBK208 includes a 100 pin P4 connector for use with DaqBoard 2000 Series and 2000c Series Boards DBK208 Ge Board for Opto 22 Solid State Relays WARNING Ensure that hard wire emergency over ride circuitry exists for all applications that make use
65. e following ESD guidelines in an appropriate ESD controlled area Such guidelines include the use of properly grounded mats and wrist straps ESD bags and cartons and related procedures Overview DaqBoard 2000 Series and DaqBoard 2000c Series boards communicate external from the host PC through the board s 100 pin P4 connector Typically a DBK200 Series P4 adapter is used to provide one or more DB37 connectors P1 P2 P3 which are subsets of the 100 pin P4 connector Pinouts for P1 P2 P3 and P4 are located after the following DBK200 Series board descriptions DaqBoard 2000 Series and cPCI DaqBoard 2000c Series boards communicate external from the host PC through the board s 100 pin P4 connector Typically a DBK200 Series P4 adapter is used to provide one or more DB37 connectors P1 P2 P3 Analog ue Digital I O CA 113 P 2 Pulse Frequency Digital amp Counter Timer O Host Computer Using a DBK201 P4 to P1 P2 P3 Adapter DaqBoard 1000 and 12000 User s Manual 898195 Connections amp Pinouts DaqBoard 2000 Series 3 1 The following matrix provides a quick comparison of the DBK200 Series adapter boards Details for each board are provided in the DBK Option Cards and Modules User s Manual p n 457 0905 An illustration and brief discussion of each DBK200 Series adapter board is presented after the following table No fr Analog IO use only NO Like DBK209 except for form factor Custom RC DBK202 is
66. er an internal onboard clock or an external clock source Analog outputs can also be updated asynchronously independent of any other scanning in the system Bus mastering DMA provides CPU and system independent data transfers ensuring accurate outputs that are irrespective of other system activities Streaming from disk or memory is supported allowing continuous nearly infinite length waveform outputs limited only by available PC system resources Channels 2 DAC channels DACO DAC1 Resolution 16 bits Output voltage range 10 V Digital Feedthru 50 mV when updated Output current 10 mA Offset error 0 0045 V maximum Gain error 0 01 Update rate 100 kHz maximum 1 5 Hz minimum no minimum with external clock Settling Time 10 us maximum to 1 LSB for full scale step Clock Sources 4 programmable 1 Onboard D A clock independent of scanning input clock 2 Onboard scanning input clock 3 External D A input clock independent of external scanning input clock 4 External scanning input clock Digital I O Applicable to DaqBoard 1000 1005 Channels 24 expandable to 208 with external DBK options Input Scanning Modes 2 programmable 1 Asynchronous under program control at any time relative to input scanning 2 Synchronous with input scanning Ports 3 x 8 bit 82C55 emulation Each port is programmable as input or output Input Characteristics 100 series 20 pF to common Input protection 8 kV ESD clamp diodes paral
67. er event from analog digital or counter readings Six pre and post triggering modes are supported The two 16 bit 100 kHz analog output channels have an output from 10 V to 10 V Using Bus Mastering DMA each D A can output a waveform Other features of the DaqBoard 1000 include e 24 TTL level digital I O lines They are divided into three 8 bit ports e Four 16 bit counters Each can accept frequency inputs up to 10 MHz The counters can be cascaded into two 32 bit counters e Two 16 bit timer outputs Each can generate square waves from 16 Hz to 1 MHz e Configuration through software There are no switches or jumpers on the DaqBoard 1000 DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 7 100 kHz Output Elek 8 DE 16 SE Analog Input Two 16 bit Digital to Analog C mrrerters signal LiD DAC ou ies oo xl 2 4 8 16 lnt 200 Hz F J Input Frogranunab le GE Analog 1 a Gain Amplifier e 5 x16 33 64 Sh Shed n dj en sh q n ba QE 512 step Analog EE Random Access iS ontrol Chameli aiti ananem Digital ee FIFO C antral Data z a m Buffer ua Di sit al LO roer anim able Sequence Tim ebase 68 Pin SCSI III 5 usto hours Comector i ee Three 8 Bit Digital LO Ports Ju system PCI f Contr oll er Controller Configurable C onfi gurable 32 Bit PLD EEPROM Data and Address
68. er s Manual 889094 Pin Function se 68 Anatoginpae Jano emon 67 rocon 66 Anaioginput Jano emro analog com analog Com Analog Common Analog Common 5 VDC Negative Reference Digital Common Digital 170 line Al Digital I O line A3 Digital Oline OOOO O as bites meni as bite nett Digital 170 line B3 as fosravomess 65 CE 63 62 61 60 59 58 56 55 54 53 52 51 50 rae 4 fosmavomea 42 fosmavomes TI aa fosavomecr 40 bstarcommen TT 39 comer nowa ae counter noer 36 Ditar commen cs Digital Common They do not apply to DaqBoard 1005 Connections amp Pinouts DaqBoard 1000 Series 2 3 2 4 Connections amp Pinouts DaqBoard 1000 Series 889094 DaqBoard 1000 and 12000 Series User s Manual Connections and Pinouts DaqBoard 2000 Series 3 Overview 3 1 DBK200 Series P4 Connector Options 3 2 Pinouts for DaqBoard 2000 Series and 2000c Series Boards 3 8 Turn off power to all devices connected to the system before connecting cables or setting configuration jumpers and switches Electrical shock or damage to equipment can result even under low voltage conditions The discharge of static electricity can damage some electronic components Semiconductor devices are especially susceptible to ESD damage You should always handle components carefully and you should never touch connector pins or circuit components unless you ar
69. ewXL and Post Acquisition Data Analysis User s Guide are not included as part of the hardcopy manual but are available in PDF version See the PDF Note below gt Programming topics are covered in the Programmer s User Manual 1008 0901 As a part of product support this manual is automatically loaded onto your hard drive during software installation The default location is the Programs directory which can be accessed through the Windows Desktop PDF During software installation Adobe PDF versions of user manuals will automatically Note install onto your hard drive as a part of product support The default location is in the Programs directory which can be accessed from the Windows Desktop Refer to the PDF documentation for details regarding both hardware and software A copy of the Adobe Acrobat Reader is included on your CD The Reader provides a means of reading and printing the PDF documents Note that hardcopy versions of the manuals can be ordered from the factory 1 24 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual Connections and Pinouts DaqBoard 1000 Series 2 Overview 2 1 TB 100 Terminal Connector Option 2 2 Pinout for DaqBoard 1000 and DaqBoardi 1005 2 3 Turn off power to all devices connected to the system before connecting cables or setting configuration jumpers and svvitches Electrical shock or damage to equipment can result even under lo
70. gt Post Acquisition Data Analysis User s Guide discusses three post acquisition data analysis programs eZ PostView eZ TimeView and eZ Frequency View gt For detailed information regarding specific DBKs refer to the DBK Option Cards and Modules User s Manual p n 457 0905 Each DBK section includes device specific hardware and software information The document includes a chapter on power management DaqBoard 1000 Series boards do not support DBK options gt For programming related information refer to the separate Programmer s Manual p n 1008 0901 DaqBoard 1000 and 2000 Series User s Manual 889094 vil This page is intentionally blank viii 889094 DaqBoard 1000 and 2000 Series User s Manual Table of Contents DaqBoard 1000 and 2000 Series Installation Guide p n 1033 0940 DaqBoard 2000c Series Installation Guide p n 1061 0940 1 Daq Systems and Device Overviews Daq Systems the Modular Concept 1 1 Theory of Operation DaqBoard 1000 and 2000 Series Boards 1 3 Using DBK Cards amp Modules for Signal Conditioning 1 23 Note DBK options do not apply to DaqBoard 1000 Series Boards Daq Software 1 23 2 Connections and Pinouts DaqBoard 1000 Series Overview 2 1 TB 100 Terminal Connector Option 2 2 Pinouts for DaqBoard 1000 Series Boards 2 3 3 Connections and Pinouts DaqBoard 2000 Series Overview 3 1 DBK200 Series P4 Connector Op
71. have multiple boards a device name is matched to a particular board by physical slot not by serial number Device Type DagBoard 2000 Device Resources Accessing the DaqBoard 2000 Properties Tab Note Images are similar for DaqBoard 1000 Series 1 Run the Daq Configuration control panel applet Navigation from the desktop to the applet is as follows Start gt Settings gt Control Panel gt Daq Configuration double click 2 Double click on the Device Inventory s DaqBoard2K0 or DaqBoard1K0 icon as applicable The DaqBoard s Properties tab will appear If the DaqBoard icon is not present skip to the upcoming Using Add Device section 3 Enter a Device Name in the text box or use the default e g DaqBoard2K0 The Name is for identifying the specific DaqBoard but actually refers to the PCI slot 4 Verify that the Device Type shows the correct board e g DaqBoard 1000 DaqBoard 2001 etc Note that available device types can be viewed via the pull down list 5 Confirm that the DaqBoard s text box shows a Bus Slot and Serial Number If this text box is empty use its pull down list and select the serial number that matches the one for your board DaqBoard 1000 and 2000 Series Installation Guide IG 5 Using Add Device This method is for users who have accessed the Daq Configuration Ree ana control panel applet but have no DaqBoard1K icon or DaqBoard2K ico
72. in 14 Analog Input Chan 4L DIF B B B Analog In Ch Analog Analog Input Chan 4 SE P1 pin 33 Analog Input Chan 4H DIF Analog Signal Common See Ground Tables B42 Analog In Ch11 Analog Analog Input Chan 11 SE P1 pin 15 Analog Input Chan 3L DIF 39 A40 41 Analog Input Chan 3H DIF Analog Signal Common Analog Input Chan 2L DIF Analog Input Chan 2H DIF Analog Input Chan 1L DIF Analog Input Chan 1H DIF Analog Signal Common Analog Input Chan OL DIF Analog Input Chan OH DIF P3 pin 37 P3 pin 19 DAC 2 and DAC 3 from P4 pins B49 and B50 respectively only apply to DaqBoard 2001 12003 12004 and the equivalent cPCI DaqBoard 2000c Series Boards 3 14 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User s Manual Ground Tables P4 Pin to P1 P2 and P3 Ground Correlation Digital Common DGND DBK200 DBK201 DBK206 DBK207 DBK208 DBK209 DBK204 i fe ee fee pit PI Analog Common AGND DBK200 DBK201 DBK202 DBK206 DBK207 DBK208 DBK209 DBK203 DBK204 DaqBoard 1000 and 2000 User s Manual 898195 Connections amp Pinouts DaqBoard 2000 Series 3 15 3 16 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User s Manual CE Compliance 4 Overview ce Overview 4 1 CE Standards and Directives 4 1 Safety Conditions 4 2 Emissions Immunity Conditions 4 2 CE Enhancements for DBKS 4 3
73. is lt 5 us e Digital and pattern triggering The DaqBoard 2001 has a separate digital trigger input line allowing TTL level triggering and latencies less than 5 us The trigger can be programmed for logic level or edge triggering In pattern triggering any of the digital input ports acts as the trigger port You can program the digital pattern e Software based triggering The PC detects the trigger event from readings either analog digital or counter Six pre and post triggering modes are supported The four 16 bit 100 kHz analog output channels have an output from 10 V to 10 V These channels are separate from the D As used to determine analog trigger levels Using Bus Mastering DMA each D A can output a waveform Bus Mastering DMA also allows for digital pattern generation on the 16 bit high speed digital I O port Other features of the DaqBoard 2001 include e 40 TTL level digital I O lines They are divided into three 8 bit ports and one 16 bit port e Four 16 bit counters Each can accept frequency inputs up to 10 MHz The counters can be cascaded into two 32 bit counters e Two 16 bit timer outputs Each can generate square waves from 16 Hz to 1 MHz e Configuration through software There are no switches or jumpers on a DaqBoard 2001 DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 13 Four 16 bit Digital to Analogj SIGNAL
74. it 2 or P2 pin 27 P2 expansion Data bit 2 Port B bit 6 Dig I O P2 Digital Port B bit 6 or P2 pin 4 P2 expansion address bit 1 A9 Port C bit 1 Dig I O P2 Digital Port C bit 1 or P2 pin 28 P2 expansion Data bit 1 P2 expansion address bit 2 P2 expansion address bit 3 This table is continued Port B bit 5 Dig I O P2 Digital Port B bit 5 or P2 pin 5 P2 expansion address bit 2 3 12 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User s Manual P2 expansion RESET P2 expansion WRITE P2 expansion READ B14 Ground See Ground Tables A15 P3 Dig bit 14 P3 pin 23 B15 i A16 i B16 A17 B17 A18 B18 A19 B19 A20 B20 A21 B21 A22 B22 A23 B23 A24 B24 A25 B25 A26 P3 Dig bit 15 P3 pin 22 P3 Dig bit 12 P3 pin 25 P3 Dig bit 13 P3 pin 24 P3 Dig bit 10 P3 pin 27 P3 Dig bit 8 Dig I O P3 Digital Port bit 8 P3 pin 29 P3 Dig bit 7 P3 pin 3 P3 Dig bit 4 P3 pin 6 P3 Dig bit 5 P3 pin 5 P3 Dig bit 2 P3 pin 8 P3 Dig bit 3 P3 pin 7 P3 Dig bit 9 Dig I O P3 Digital Port bit 9 P3 pin 28 P3 Dig bit 0 Dig I O P3 Digital Port bit 0 P3 pin 10 P3 Dig bit 6 Dig I O P3 Digital Port bit 6 P3 pin 4 P3 Dig bit 1 Dig I O P3 Digital Port bit 1 P3 pin 9 XCK Dig I O No Connection Ground Dig I O Digital Common 5ee Ground Tables Timer 0 Dig OUT P3 Timer 0 Output P3 pin 15 Timer 1 Dig OUT P3 Timer 1 Output P3 pin 16 Ground Dig I O Digital Common 5ee Ground Tables Ground Dig I O Digital Common 5ee G
75. it port e Four 16 bit counters Each can accept frequency inputs up to 10 MHz The counters can be cascaded into two 32 bit counters e Two 16 bit timer outputs Each can generate square waves from 16 Hz to 1 MHz e Configuration through software There are no switches or jumpers on a DaqBoard 2004 DaqBoard 1000 and 12000 Series User s Manual 889094 Daq Systems and Device Overviews 1 19 SHALL WO P a Four 16 bet DAC OUT Hift n na Pa F Qi ANALOG H CONTROL PE F External E MUX Controij 512 step s Random Access s Channelsain amp Sequencer a DIGITAL H Ki CONTROL Bytter Programmable DE 8 Fa Sequence DIGITAL WO ae Timebase so 5 pus to 6 hours J g EET Pisia ps Three amp bit Digital VO Ports PT 100 kHir i G p A Teen System PC I Controlle i Controller Configurable I Configurable 32 bit Data and PLD EEPROM Address Bus DaqBoard 2004 Block Diagram The DaqBoard 2004c Block Diagram is the same with exception that the 2004c board uses a compact PCI Bus instead of a standard PCI bus Connections Installation Reference Note For the DaqBoard 2004 and DaqBoard 2004c installation procedure refer to either the DaqBoard 1000 and 2000 Series Installation Guide or to the DaqBoard 2000c Series Installation Guide as applicable The guides are included at the beginning of this manual VO Connector All input and output signals are av
76. ks Bus Mastering DMA is utilized to provide CPU and system independent data transfers insuring data acquisition performance irrespective of other system activities Scan Clock Sources 2 1 Internal programmable from 5 us to 5 96 hours maximum in 5 us steps 2 External TTL level input up to 200 kHz maximum Programmable parameters per scan channel random order gain unipolar bipolar Depth 512 locations On board Channel to channel scan rate 5 or 10 us per channel programmable Expansion channel scan rate 5 or 10 us per channel programmable External Acquisition Scan Clock Input Applicable to DaqBoard 2000 12001 12005 Maximum rate 200 kHz Signal Range OV to 5V Input Characteristics 100 series 20 pF to common and 10 kQ to 5V Input protection 8 kV ESD clamp diodes parallel Trigger Level TTL Slew Rate Requirement 14 V us minimum Minimum pulse width 50 ns high 50 ns low Triggering Applicable to DaqBoard 2000 2001 2005 Trigger Sources 6 individually selectable for starting and stopping an acquisition Stop acquisition can occur on a different channel than start acquisition stop acquisition can be triggered via modes 2 4 5 or 6 described below Pre trigger is supported with fixed or variable pre trigger periods 1 Single Channel Analog Hardware Trigger Any analog input channel can be software programmed as the analog trigger channel including any of the 256 analog expansion channels Input Signal
77. lel I O levels TTL Sampling Update rate 200 kHz maximum Output Characteristics Output 12 mA per pin 200 mA total continuous per bank of 24 outputs Counters Applicable to DaqBoard 1000 1005 Counter inputs can be scanned synchronously along with analog and digital scanned inputs based either on internal programmable timer or an external clock source Bus mastering DMA provides CPU and system independent data transfers insuring data acquisition performance irrespective of other system activities Counters can be configured to clear when read or to totalize and clear under program control Channels 4 x 16 bit cascadable as 2 x 32 bit Frequency Measurement Rate 10 MHz maximum Input Signal Range 15 V to 15 V Input Characteristics 2 7 kQ series in parallel with 20 pF to common and 10 kQ to 5 V Input protection 8 kV ESD clamp diodes parallel Trigger Level TTL Minimum pulse width 50 ns high 50 ns low Note Specifications subject to change without notice 889094 Specifications DaqBoard 1000 Series 6 3 Frequency Pulse Generators Applicable to DaqBoard 1000 11005 Channels 2 x 16 bit Output Waveform Square wave Output rate 1 MHz base rate divided by 1 to 65535 programmable High level output voltage 2 0 V minimum 3 75 mA 3 0 V minimum 2 5 mA Low level output voltage 0 4 V maximum 2 5 mA Accessories and Cables Applicable to DaqBoard 1000 11005 Termination Board TB 100 Termination board with s
78. lock Input Applicable to DaqBoard 1000 11005 Maximum rate 200 kHz Clock Signal Range OV to 5V Minimum pulse width 50 ns high 50 ns low Triggering Applicable to DaqBoard 1000 1005 Trigger Sources 4 individually selectable for starting and stopping an acquisition Stop acquisition can occur on a different channel than start acquisition stop acquisition can be triggered via modes 2 3 or 4 described below Pre trigger is supported with fixed or variable pre trigger periods 1 Single Channel Digital Trigger A separate digital input is provided for digital triggering Latency 5 us max 2 Digital Pattern Triggering 8 or 16 bit pattern triggering on any digital input Programmable for trigger on equal above below or within or outside of a window Individual bits can be masked for don t care condition Latency One scan period maximum 3 Counter Totalizer Triggering Counter totalizer inputs can trigger an acquisition User can select to trigger on a frequency or on total counts that are equal above below or within outside of a window Latency One scan period maximum 4 Software Triggering Trigger can be initiated under program control 6 2 Specifications DaqBoard 1000 Series 889094 Note Specifications subject to change vvithout notice Analog Outputs Applicable to DaqBoard 1000 does not apply to DaqBoard 1005 Two analog output channels are updated synchronously relative to scanned inputs and clocked from eith
79. n as described on page IG 5 step 21 A After accessing the Dag Configuration control panel applet click on Hanes twa the lt Add Device gt button see figure right The Select Device Type DagBoara 2o00 nj window will appear B Using the Device Type s pull down list select the applicable board In the example at the right DaqBoard 2000 is selected C Click the lt OK gt button The board s Properties tab will appear Note that this tab will apply to all boards in the series OK Cancel At this point complete steps 3 through 5 from page IG 5 Using Add Device Step 4 Test Hardware Use the following steps to test the DaqBoard board Note that these steps are continued from those listed under the previous section Configure Board 1 Select the Test Hardware tab 2 Dag Configuration 2 Click the Resource Test button rer i DaqBoard 2000 Properties Test Hardware 1 3 After the test is complete click OK Prior to testing please make sure your device it connected bo the PC System capability is now tested for the DaqBoard and a list IF pour computer does not respond for 30 seconds please of test results appears on screen reboot and change the settings in the configuration utility Test Results Mo tests have beer run Torun click Test includes a troubleshooting chapter as well as a great OK C ul deal of information regarding specifi
80. n User can select to trigger on a frequency or on total counts that are equal above below or within outside of a window Latency One scan period maximum 6 Software Triggering Trigger can be initiated under program control Analog Output Applicable to DaqBoard 2000 12001 12003 12004 The analog output channels are updated synchronously relative to scanned inputs and clocked from either an internal onboard clock or an external clock source Analog outputs can also be updated asynchronously independent of any other scanning in the system Bus mastering DMA provides CPU and system independent data transfers ensuring accurate outputs that are irrespective of other system activities Streaming from disk or memory is supported allowing continuous nearly infinite length waveform outputs limited only by available PC system resources Channels DaqBoard 2000 2 DAC channels DACO DAC1 DaqBoard 2001 2003 2004 4 DAC channels each DACO DAC1 DAC2 and DAC3 Resolution 16 bits Output voltage range 10 V Output current 10 mA Offset error 0 0045 V maximum Digital Feedthru 50 mV when updated Gain error 0 01 Update rate 100 kHz maximum 1 5 HZ minimum no minimum with external clock Settling Time 10 us maximum to 1 LSB for full scale step Clock Sources 4 1 Onboard D A clock independent of scanning input clock 2 Onboard scanning input clock 3 External D A input clock independent of external scanning input clock
81. nces may be made to other chapters or other documentation Tips provide advice that may save time during a procedure or help to clarify an issue Tips may include additional reference Specifications and Calibration Specifications are subject to change without notice Significant changes will be addressed in an addendum or revision to the manual As applicable the hardware is calibrated to published specifications Periodic hardware calibration is not covered under the warranty and must be performed by qualified personnel as specified in this manual Improper calibration procedures may void the warranty Your order was carefully inspected prior to shipment When you receive your system carefully unpack all items from the shipping carton and check for physical signs of damage that may have occurred during shipment Promptly report any damage to the shipping agent and your sales representative Retain all shipping materials in case the unit needs returned to the factory Using this equipment in ways other than described in this manual can cause personal injury or equipment damage Before setting up and using your equipment you should read all documentation that covers your system Pay special attention to Warnings and Cautions Note PDF 1033 0901 During software installation Adobe PDF versions of user manuals will automatically install onto your hard drive as a part of product support The default location is in the Programs gr
82. number information Using Add Device This method is for users who have accessed the Daq Configuration control panel applet but have no DaqBoard2K icon as described in step 2 above r Device Type A After accessing the Daq Configuration control panel applet click on the Add DaqBoara 200 4 Device button see figure right The Select Device Type window will appear B Using the Device Type s pull down list select the applicable board In the example at the right DaqBoard 2000 is selected C Click the OK button The DaqBoard 2000 Properties tab will appear This tab applies to all boards in the DaqBoard 2000 Series At this point complete steps 3 through 5 from above Using Add Device Step 4 Test Hardware Use the following steps to test the DaqBoard 2000 Series board Note that these steps are continued from those listed under the previous section Configure Board 1 Select the Test Hardware tab z4 Dag Configuration 2 Click the Resource Test button cc 55 DaqBoard 2000 Properties Test Hardware 1 3 After the test is complete click OK Prior to testing please make sure your device is connected to the PC System capability is now tested for the DaqBoard 2000 IF your computer does not respond for 30 seconds please Series board and a list of test results appears on screen reboot and change the settings in the configuration utility
83. o screen appears follow the screen prompts Upon completing the software installation continue with step 2 Install Boards in available PCI Bus slots IG 2 DaqBoard 1000 and 12000 Series Installation Guide 898195 1033 0940 rev 8 0 Step 2 Install Boards in available PCI Bus slots IMPORTANT Software must be installed before installing hardware Turn off power to and UNPLUG the host PC and externally connected equipment prior to removing the PC s cover and installing the DaqBoard Electric shock or damage to equipment can result even under low voltage conditions Take ESD precautions packaging proper handling grounded wrist strap etc Use care to avoid touching board surfaces and onboard components Only handle boards by their edges or ORBs if applicable Ensure boards do not come into contact with foreign elements such as oils water and industrial particulate IMPORTANT Bus Mastering DMA must be Enabled For a DaqBoard 1000 or 2000 Series board to operate properly Bus Mastering DMA must be Enabled on the PCI slot for which the board is to be installed Prior to installation verify that your computer is capable of performing Bus Mastering DMA for the applicable PCI slot Note that some computers have BIOS settings that enable or disable Bus Mastering DMA If your computer has this BIOS option ensure that Bus Mastering DMA is Enabled on the appropriate PCI slot Refer to your PC Owner s Manual for ad
84. onverter digital calibration bus mastering DMA four 16 bit 100 kHz D A converters 40 digital I O lines four counters and two timers Up to 470 channels of analog and digital I O can be accessed with one DaqBoard 2001 board Up to four boards can be installed into a PC A 100 pin connector on the DaqBoard 2001 provides access to all of the input and output signals The boards accommodate all I O with one cable and one PCI or compact PCI slot The 100 pin I O connector P4 is logically divided into three ports e P1 Analog input port for16 single ended or 8 differential analog inputs with 13 software programmable ranges 10 V to 156 mV full scale e P2 General purpose digital I O port with 24 lines or digital I O expansion port controlling up to 192 external lines e P3 16 bit digital I O port counter inputs timer outputs and analog outputs The on board scan sequencer lets you select up to 512 channel range combinations The sequencer scans all channels of the scan at 5us channel or 10us channel Bus mastering allows analog and digital counter input data as well as analog and digital output data to flow between the PC and the DaqBoard 2001 without consuming CPU time DaqBoard 2001 supports a full complement of trigger modes including e Hardware analog triggering A user programmed trigger level sets an analog DAC which is compared in hardware to the analog input level on the selected channel Trigger latency
85. or P2 compatible DBK digital input expansion modules Refer to the applicable pinouts to see how P1 P2 and P3 relate to the 100 pin P4 connector DaqBoard 1000 Series boards do not support DBK options Analog Input Channels The boards that offer analog input see previous matrix allow analog input configuration for the board For applicable DaqBook 2000 Series boards analog input can be received from P1 compatible DBK analog input expansion modules Channel Selection and Mode Settings The main unit accepts up to 16 single ended or up to 8 differential ended inputs and can be programmed for single ended or differential ended on a per channel basis In regard to DaqBoard 2000 Series boards just one analog channel is sacrificed when a DBK expansion module is enabled See DBK documentation in the DBK Option Cards amp Modules User s Manual p n 457 0905 for further information Channel Range and Polarity DaqBoard 2000 Series board channels can be programmed for either unipolar or bipolar mode with gain settings of 1 2 4 8 16 32 and 64 DaqBoard 1000 Series boards have the same gains but are only bipolar Channel Sampling Interval The boards allow programmable sampling intervals of Sus or 10us on a per channel basis This mode allows some channels which change slowly but a higher degree of accuracy is desirable to be sampled at a longer interval while channels that change more rapidly to be sampled using a shorter interval Each 5us or 1Qu
86. oup which can be accessed from the Windows Desktop Initial navigation is as follows Start Desktop Start pull down menu gt Programs gt IOtech DaqX Software You can also access the PDF documents directly from the data acquisition CD by using the lt View PDFs gt button located on the opening screen Refer to the PDF documentation for details regarding both hardware and software A copy of the Adobe Acrobat Reader is included on your CD The Reader provides a means of reading and printing the PDF documents Note that hardcopy versions of the manuals can be ordered from the factory DaqBoard 1000 and 2000 Series pdf Contains the DaqBoard 1000 and 2000 Series hardware related and software related chapters as well as links to the pdf files listed below This pdf file plus the following constitute a complete set of documentation for the DaqBoards discussed Note that the Programmer s Manual 1008 0901 and the DBK Option Cards amp Modules 457 0905 are completely separate documents The later does not apply to DaqBoard 1000 Series boards PDF 457 0909 PDF 1086 0926 1086 0922 DaqView pdf Discusses how to install and use this out of the box data acquisition program PostAcquisition Analysis pdf This pdf consists of two documents The first discusses eZ PostView a post data acquisition analysis program The application is included free as a part of DaqTemp product support The second inclu
87. p to four D A channels Each D A channel may be asynchronously updated by an application if the D A channel is not currently being used for waveform output operations Counter Input Channels With exception of DaqBoard 2003 the boards have counter input capabilities and have the ability to read counter input if the counter channel is not configured for synchronous acquisition As in the case of synchronous operations the 4 16 bit counter input channels can be used individually or cascaded into two 32 bit counter channels For either cascaded or non cascaded counter channels each channel can be configured for e Clear on Read Mode specifies that each counter should be cleared reset to 0 upon being read e Continuous Totalize Mode specifies that each counter is to free run and not be cleared during the read operation Operation Matrix 1000 1005 2000 2001 2002 2003 2004 2005 ET NE ye Yes x iz E Yes ves m reel Yes reno TT Yes A similar matrix intended to highlight board differences at a glance is presented on page 1 3 1 6 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 1000 Digital j om 16 Analog 2 Analog 24 Digital 4 Counter 2 Timer Input Output I O Inputs Outputs DaqBoard 1000 is a high speed multi function plug and play data acquisition board for PCI bus computers It fe
88. pment 3 UNPLUG the host PC and all externally connected equipment 4 Remove the PC s cover Refer to your PC Owner s Manual as needed 5 Locate the DaqBoard 2000 Series Board and carefully remove the board from its PCI slot For cPCI DaqBoard 2000c Series Boards cPCI Type 1 Turn the compact PC s power OFF Upper Lock Screw 2 Turn power OFF to externally connected equipment 3 UNPLUG the compact PC and all externally connected equipment 4 Loosen the upper and lower lock screws see figure 5 Push the cPCI board s injector ejector down to disengage the board 6 Slide the board free of the compact PC ower Lock Screw ss Removing a cPCI DaqBoard 2000c Series Board DaqBoardi 1000 and 12000 Series User s Manual 959495 CE Compliance 4 3 Install the CE ORB 1 Remove the two screws that secure the standard non CE ORB to the board see figures 2 Using the same screws mount the CE ORB to the board Tighten the screws snug but do not over tighten Note For the cPCI DaqBoard 2000c Series Boards the board s edge will locate between the ORB s Retaining Edge and the two screw mounts cPCI DaqBoard 2000c series Board Replaces EN ore n CE ORB for 2000c Series Boards Mounting DaqBoard 2000 Series and cPCI DaqBoard 2000c Series Boards to CE ORBs Install the Board with its CE ORB For DaqBoard 2000 Series Boards PCI type N If you a installing the DaqBoard 2000 Series Board fo
89. r the first time refer to chapter 1 of this manual 3 or to the DaqBoard 2000 Series Quick Start Guide prior to installing the board 1 If you have not already done so turn off power to and a Align Groove in Edge Connector UNPLUG the host PC and externally connected Sn ee Rela equipment Then remove the PC s cover Refer to your i Replace 2 PC Owner s Manual as needed Screw 2 Install the DaqBoard 2000 Series Board with CE ORB as follows a Align the groove in the edge connector with the b Push Board ridge on the PCI slot Firmly into PCI Slot b Push the DaqBoard 2000 Series Board firmly into the PCT slot Installing a DaqBoard 2000 Series Board c Replace the rear panel adapter screw 3 Replace the PC s cover 4 4 CE Compliance 959495 DaqBoard 1000 and 12000 Series User s Manual For cPCI DaqBoard 2000c Series Boards cPCI Type AP If you a installing the cPCI DaqBoard 2000c Series Board for the first time refer to chapter 2 of this WS manual or to the cPCI DaqBoard 2000c Series Quick Start Guide prior to installing the board ig Turn the compact PC s power OFF 2 Turn power OFF to externally connected equipment 3 UNPLUG the compact PC and all externally connected equipment 4 With the board s injector ejector down slide the board into the compact PC Make sure you use the PCs card guides 5 After the board is inserted pull the cPCI board s injector ejector up to
90. rd 1000 Series boards 1 2 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual Theory of Operation for DaqBoard 1000 and 2000 Series Boards As implied by the following matrix the operational material does not apply globally to every board For example DaqBoard 1005 2002 and 2005 have no analog output channels For ease of understanding each board is discussed independently following the matrix Note that pinouts are provided in chapter 2 for the DaqBoard 1000 Series and in chapter 3 for the DaqBoard 2000 Series IO Comparison Matrix I O Comparison Matrix for DaqBoard 1000 and 2000 Series Boards DaqBoard Analog Input Analog Output Digital I O Counter Timer I dentity Channels Channels Channels Inputs Outputs i Note DaqBoard 1000 Series boards do not support DBK options DaqBoard 1000 and 2000 Series User s Manual 889094 Daq Systems and Device Overviews 1 3 Synchronous Input Operations for DaqBoard 1000 and DaqBoard 2000 Series Boards As indicated in the I O matrix applicable DaqBoards allow for synchronous scanning and acquisition of Analog Input Digital Input and Counter Input Data at up to 200kHz aggregate scanning rates For applicable DaqBoard 2000 Series devices the Analog Input data can be either directly to the board or from expansion analog input modules connected to Pl The Digital Input data can be to the board s 8 bit P2 8255 digital inputs 16 bit P3 digital inputs
91. rmity and include CISPR22 1985 EN55022 1988 Information Technology Equipment Class A for commercial industrial use and EN50082 1 1992 for various categories of EMI immunity The safety standard that applies to Daq products is EN 61010 1 1993 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use Part 1 General Requirements Environmental conditions include the following e indoor use e altitude up to 2000 m e temperature 5 C to 40 C 41 F to 104 F e maximum relative humidity 80 for temperatures up to 31 C 87 8 F decreasing linearly to 50 relative humidity at 40 C 104 F e mains supply voltage fluctuations not to exceed 10 of the nominal voltage e other supply voltage fluctuations as stated by the manufacturer e transient overvoltage according to installation categories overvoltage categories I II and III For mains supply the minimum and normal category is II e pollution degree I or II in accordance with IEC 664 DaqBoard 1000 and 12000 Series User s Manual 959495 CE Compliance 4 1 For clarification terms used in some Declarations of Conformity include e pollution degree any addition of foreign matter solid liquid or gaseous ionized gases that may produce a reduction of dielectric strength or surface resistivity Pollution Degree I has no influence on safety and implies the equipment is at operating temperature with non condensing humidity conditions no cond
92. round Tables DAC Pacer Dig VO External DAC Pacer Clock Input P3 pin 21 Internal DAC Pacer Output P3 Dig bit 11 Dig I O P3 Digital Port bit 11 P3 pin 26 B26 ADC Pacer Dig I O External ADC Pacer Clock Input P1 pin 20 Internal ADC Pacer Output XI O Gain 0 Dig OUT Analog Expansion Gain Select bit 0 P1 pin 6 TTL Trigger P1 pin 25 Ground Digital Common See Ground Tables Counter 3 P3 pin 35 Counter 2 P3 pin 17 Counter 1 P3 pin 36 Counter 0 P3 pin 18 CD ACK No Connection SDI No Connection Ground See Ground Tables XI O Gain 1 P1 pin 5 XI O Address 3 P1 pin 3 XI O Address 2 P1 pin 22 XI O Address 1 P1 pin 4 XI O Address 0 P1 pin 23 Sample Hold Signal Ground See Ground Tables Positive Ref P1 pin 9 Negative Ref Analog 5 Volt Reference P1 pin 8 Analog In Ch15 Analog Input Chan 15 SE P1 pin 11 Analog Input Chan 7L DIF A37 Analog In Ch7 Analog Input Chan 7 SE P1 pin 30 Analog Input Chan 7H DIF Ground See Ground Tables Analog In Ch14 Analog Input Chan 14 SE P1 pin 12 Analog Input Chan 6L DIF B38 Analog In Ch6 Analog Analog Input Chan 6 SE P1 pin 31 Analog Input Chan 6H DIF A39 Ground See Ground Tables U S w Q a Q Q S I ag QD DaqBoard 1000 and 2000 User s Manual 898195 Connections amp Pinouts DaqBoard 2000 Series 3 1 Analog Input Chan 5L DIF Analog Input Chan 5H DIF B40 Analog Signal Common See Ground Tables B40 A41 Analog In Ch12 Analog Analog Input Chan 12 SE P1 p
93. rry the CE marker indicating they comply with the safety and emissions standards of the European Community When applicable these products have a Declaration of Conformity stating which specifications and operating conditions apply You can view the Declarations of Conformity at www mccdaq com legal aspx CE Information page Cautions Notes and Tips Refer all service to qualified personnel This caution symbol warns of possible personal injury or equipment damage under noted conditions Follow all safety standards of professional practice and the recommendations in this manual Using this equipment in ways other than described in this manual can present serious safety hazards or cause equipment damage This warning symbol is used in this manual or on the equipment to warn of possible injury or death from electrical shock under noted conditions This ESD caution symbol urges proper handling of equipment or components sensitive to damage from electrostatic discharge Proper handling guidelines include the use of grounded anti static mats and wrist straps ESD protective bags and cartons and related procedures This symbol indicates the message is important but is not of a Warning or Caution category These notes can be of great benefit to the user and should be read In this manual the book symbol always precedes the words Reference Note This type of note identifies the location of additional information that may prove helpful Refere
94. s 10 V to 156 mV full scale e P2 General purpose digital I O port with 24 lines or digital I O expansion port controlling up to 192 external lines e P3 16 bit digital I O port counter inputs and timer outputs The on board scan sequencer lets you select up to 512 channel range combinations The sequencer scans all channels of the scan at 5 us channel or 10 us channel Bus mastering allows analog and digital counter input data as well as analog and digital output data to flow between the PC and the board without consuming CPU time DaqBoard 2005 supports a full complement of trigger modes including e Hardware analog triggering A user programmed trigger level sets an analog DAC which is compared in hardware to the analog input level on the selected channel Trigger latency is lt 5 us e Digital and pattern triggering Both boards have a separate digital trigger input line allowing TTL level triggering and latencies less than 5 us The trigger can be programmed for logic level or edge triggering In pattern triggering any of the digital input ports acts as the trigger port You can program the digital pattern e Software based triggering The PC detects the trigger event from readings either analog digital or counter Six pre and post triggering modes are supported Bus Mastering DMA also allows for digital pattern generation on the 16 bit high speed digital I O port Other features of the DaqBoard 2005 in
95. s interval reduces the maximum aggregate acquisition rate for the entire scan by that amount Digital Input Channels Associated boards allow either synchronous scanning of digital input channels or asynchronous I O operations for all configured digital channels Counter Input Channels Associated boards allow synchronous scanning of the 4 16 bit counter input channels The four 16 bit counter channels can also be cascaded into two 32 bit counter channels For either cascaded or non cascaded counter channels each channel can be configured for e Pulse Counting Mode specifies that each counter should be cleared upon being read and placed into the input scan e Totalize Counting Mode specifies that each counter is to free run and not be cleared during the input acquisition Synchronous Input Acquisition Clocking Associated boards allow clocking of the synchronized inputs either by an internal programmable pacer clock or by external clocking These products use a sequencer to implement a multiplexing approach to gathering the input data This means that with either internal or external clocking the entire channel scan including the sampling time for each channel may not exceed the maximum aggregate rate of 200kHz 1 4 Daq Systems and Device Overviews 889094 DaqBoard 1000 and 2000 Series User s Manual Synchronous Output Operations The DaqBoard 1000 allows synchronous output of any D A channels available at up to 100kHz for each
96. se of one SY OeR HSA TEASE YVOCHP LA BS Digital 4 Digital 12 Digital 3 Digital 11 of the Digital 2 Digital 10 following Digital 1 Digital 9 Digital 0 Digital 8 Digital Ground Digital Ground a Expansion 2 Expansion 1 Analog Out DAC 3 DBK201 t Ke Expansion 3 Expansion 0 Analog Out DAC 2 DBK202 Note 1 E GR SA acy cee Fa Fy amp Expansion 4 Analog Out DAC 1 Yl er Fee ee Pee se es SS SN Timer 0 Analog Out DAC 0 DBK203 Note 1 i TARRE 99 S S Timer 1 Counter 3 DBK204 Note 1 SS SITS 9 g SFF Counter 2 Counter 1 Ke SP Counter 0 15 Volts DBK206 Ko t t 15 Volts Digital Ground DBK209 v NN Digital Ground No Pin DB37 P3 Connector Note There is no direct pin number correlation between the 40 pin header and the DB37 P3 connector eas epee DBK204 In regard to pins 31 through 34 see Note 3 On Board 40 Pin Header The P3 DB37 connector does not apply to DBK200 DBK205 DBK207 DBK207 CJC or DBK208 Signal Name Description for P3 Pin Use P4 Correlation 6 Digital4 P8DigitalPortBit4 A 8 Digtal2 P3DigitalPortBit2 A 9 Digital P8DigitalPortBit1 BT 12 Expansion2 Reserved me y 13 Expansion3 fReseved mme 14 Expansion4 fReseved mm Analog Out DAC 0 Note 3 15 Volts Expansion 15 VDC Power Refer to Power Management ch 2 in DBK Manual Note 1 P3 pins 1 and 2 are not connected on DBK201 Note 2 For DBK202 DBK203 and DBK204 the 37 pin P3 connector is obtained by connecting a CA 60
97. signal interference more commonly referred to as noise A digital signal is one of discrete value in contrast to a varying signal Combinations of binary digits Os and Is represent digital data 959395 G 1 Digital to Analog Converter DAC DIP switch Differential mode Differential mode voltage ESD Excitation Gain Isolation Linearization Multiplexer MUX Sample reading Scan Sequencer Simultaneous Sample and Hold Single ended mode G 2 A circuit or device that converts digital values binary bits into analog signals A DIP switch is a group of miniature switches in a small Dual In line Package DIP Typically users set these switches to configure their particular application The differential mode measures a voltage between 2 signal lines for a single channel Also see single ended mode Differential mode voltage refers to a voltage difference between two signals that are referenced to a common point Example Signal I is 5 VDC referenced to common Signal 2 is 6 VDC referenced to common If the 5 VDC signal is used as the reference the differential mode voltage is 1 VDC 6 VDC 5 VDC 1 VDC If the 6 VDC signal is used as the reference the differential mode voltage is 1 VDC 5 VDC 6 VDC 1 VDC Electrostatic discharge ESD is the transfer of an electrostatic charge between bodies having different electrostatic potentials This transfer occurs during direct conta
98. slot The 100 pin I O connector P4 is logically divided into three ports e PI Analog input port for16 single ended or 8 differential analog inputs with 13 software programmable ranges 10 V to 156 mV full scale e P2 General purpose digital I O port with 24 lines or digital I O expansion port controlling up to 192 external lines e P3 16 bit digital I O port counter inputs timer outputs and analog outputs The on board scan sequencer lets you select up to 512 channel range combinations The sequencer scans all channels of the scan at 5us or 10 us channel Bus mastering allows analog and digital counter input data as well as analog and digital output data to flow between the PC and the DaqBoard 2000 without consuming CPU time DaqBoard 2000 supports a full complement of trigger modes including e Hardware analog triggering A user programmed trigger level sets an analog DAC which is compared in hardware to the analog input level on the selected channel Trigger latency is lt 5 us e Digital and pattern triggering The boards have separate digital trigger input line allowing TTL level triggering and latencies less than 5 us The trigger can be programmed for logic level or edge triggering In pattern triggering any of the digital input ports acts as the trigger port You can program the digital pattern e Software based triggering The PC detects the trigger event from readings either analog digital or
99. sult your PC owner s manual as needed 2 DaqBoard 2000 Series users should read about the DBK cards and modules applicable to their acquisition system Specific DBK information can be found in the world wide web at http www daqboard com and in the DBK Option Cards and Modules User s Manual p n 457 0905 After the install you can navigate to the DBK manual and other relevant electronic documents from your desktop as follows Start gt Programs gt IOtech DaqX Software gt DaqBoard 2000 Series Users Note DaqBoard 1000 Series boards do not support DBK options Minimum System Requirements PC system with Pentium Processor Windows Operating System RAM as follows 32 Mbytes of RAM for Windows 95 98 NT 64 Mbytes of RAM for Windows Me 64 Mbytes of RAM for Windows 2000 64 Mbytes of RAM for Windows XP Q Install Board in PCI Slot Configure Board through software Test Hardware through software Installation A Pictorial Overview Step 1 Install Software IMPORTANT Software must be installed before installing hardware 1 Remove previous version Daq drivers if present You can do this through Microsoft s Add Remove Programs feature 2 Place the Data Acquisition CD into the CD ROM drive Wait for PC to auto run the CD This may take a few moments depending on your PC If the CD does not auto run use the Desktop s Start Run Browse feature and run the Setup exe file 3 After the intr
100. t C Bit 6 or P2 Expansion Data Bit 6 BG Digital I O P2 Digital Port C Bit 5 or P2 Expansion Data Bit 5 A Digital VO P2 Digital Port C Bit 4 or P2 Expansion Data Bit 4 Br Digital VO P2 Digital Port C Bit 3 or P2 Expansion Data Bit 3 A Digital VO P2 Digital Port C Bit 2 or P2 Expansion Data Bit 2 B8 Digital I O P2 Digital Port C Bit 1 or P2 Expansion Data Bit 1 A9 Digital I O P2 Digital Port C Bit 0 or P2 Expansion Data Bit 0 B9 Digital VO P2 Digital Port A Bit 7 or P2 Expansion Data Bit 15 Digital I O P2 Digital Port A Bit 6 or P2 Expansion Data Bit 14 Digital I O P2 Digital Port A Bit 5 or P2 Expansion Data Bit 13 AS 1 Digital VO P2 Digital Port A Bit 4 or P2 Expansion Data Bit 12 B3 1 Digital VO P2 Digital Port A Bit 3 or P2 Expansion Data Bit 11 AM Digital VO P2 Digital Port A Bit 2 or P2 Expansion Data Bit 10 BA Digital VO P2 Digital Port A Bit 1 or P2 Expansion Data Bit 9 AS o o Digital VO P2 Digital Port A Bit 0 or P2 Expansion Data Bit 8 BE 3 10 Connections amp Pinouts DaqBoard 2000 Series 898195 DaqBoard 1000 and 2000 User s Manual P3 for DaqBoard 2000 Series and 2000c Series Boards Pulse Frequency Digital I O P3 The P3 DB37 NN Lvov el deka OI LEA wow EEE es yo igital Groun nalog oc connector Is S SS S ETE S Z SN oe Digital 7 Digital 15 obtained with gt PSS SSS SESS EEELE SSO a arene PP SSLSP ISL ISIS OSE SFE Digital 5 Digital 13 the u
101. tall CD Customers who did not order DaqView 2000 can run a 30 day free trial version as discussed in the user s manual Take ESD precautions packaging proper handling grounded wrist strap etc Use care to avoid touching board surfaces and onboard components Only handle boards by their edges or ORBs if applicable Ensure boards do not come into contact with foreign elements such as oils water and industrial particulate Reference Note During software installation Adobe PDF versions of user manuals are automatically installed onto your hard drive as a part of product support The default location is in the Programs group which can be accessed from the Windows Desktop A copy of the Adobe Acrobat Reader is included on your CD The Reader provides a means of reading and printing the PDF documents Note that hardcopy versions of manuals can be ordered from the factory Note In regard to functionality the DaqBoard 2000c Series boards are identical to their DaqBoard 2000 Series counterparts 979294 061 0940 rev 4 0 IG 1 Reference Notes gt Each DaqBoard 2000c Series Board plugs into a 5 volt compact PCI bus slot located on the PC s backplane Note that the 5 V compact PCI bus slot contains a blue key see page 3 Consult your PC owner s manual as needed gt Be sure to read about the DBK cards and modules applicable to your acquisition system Specific DBK information can be found in on the world wide we
102. te unfiltered Absolute Typical 2 Accuracy specification is 0 to 10 V 0 015 005 exclusive of noise 0 to 5 V 0 015 005 ME a 3 Inputs shorted to P4 45A 0to 2 5V 0 015 005 if differential input 8192 Oto 125V 00154008 2 samples 0to 0 625V_ 0015 008 fJ 2 Oto 40 3125V 00184008 f 2 10to 10V_ 00400 1 Stos v 00164008 1 25t0 25V 0 0151 005 1 I 2I1 2IDIDIN Voltage Specifications one year 0 35 C Applicable to DaqBoard 2000 2001 2005 Differential Nonlinearity 2 LSB maximum Integral Nonlinearity 1 LSB maximum Temperature Coefficient 10 ppm 0 3 LSB C typical Input Impedance 10 MQ single ended 20 MQ differential in parallel with 50 pF Bias Current lt 1 nA 0 to 35 C Common Mode Rejection 86 dB typical from DC to 60 Hz for gains lt 8 95 dB typical from DC to 60 Hz for gains 216 Hostile Channel to channel Crosstalk 100 dB DC to 60 Hz 86 dB 10 kHz Maximum Input Voltage 11 V relative to analog common Over Voltage Protection 35 V relative to analog common 7 2 Specifications DaqBoard 2000 Series 889094 Note Specifications subject to change without notice Input Sequencer Applicable to DaqBoard 2000 2001 2002 2004 2005 Analog digital and counter inputs can be scanned synchronously based either on an internal programmable timer or an external clock source Analog and digital outputs can also be synchronized to either of these cloc
103. tep 1 Install Software page 2 Step 2 Install Boards into Available 5 Volt Compact PCI Bus Slots page 2 Step 3 Configure Boards page 4 Step 4 Test Hardware page 5 Reference Note After you have completed the installation you should refer to the electronic documents that were automatically installed onto your hard drive as a part of product support The default location is in the Programs group which can be accessed from the Windows Desktop You should keep your DaqBoard 2000c Series board s serial number and your Daq View 2000 authorization code if applicable with this document Space is provided below for recording up to 4 board numbers and their compact PCI bus slot location Board serial numbers are located on the 100 pin P4 connector mn Board Type Serial Number Compact PCI Bus Slot Location e g DaqBoard 2005c PT d G y O Board 2 Board 3 Board 4 Compact PC support for DaqBoard 2000c Series boards varies A system can support no more than four boards Note The DaqBoard 2000c Series boards have their board identity indicated on the latch as indicated in the photo on the front page of this guide This identification is provided since the boards look very much alike and are visually identical once installed DaqView 2000 Authorization Code Customers who ordered DaqView 2000 can find their authorization code on the authorization code sheet located inside the sleeve of the ins
104. tep 2 Install Boards in available 5 Volt Compact PCI Bus slots Step 2 Install Boards in available 5 Volt Compact PCI Bus slots IMPORTANT Software must be installed before installing hardware IMPORTANT Bus Mastering DMA must be Enabled For a DaqBoard 2000c Series board to operate properly Bus Mastering DMA must be enabled Prior to installation verify that your computer is capable of performing Bus Mastering DMA for the applicable compact PCI bus slot Note that some computers have BIOS settings that enable or disable Bus Mastering DMA If your computer has this BIOS option ensure that Bus Mastering DMA is Enabled on the appropriate compact PCI bus slot Refer to your PC s owner manual for additional information regarding Bus Mastering DMA IMPORTANT The Compact PCI Bus Slot must be keyed for 5 Volt use Note The 5 Volt Key location is indicated in the first photograph on page 3 IG 2 DaqBoard 2000c Series Installation Guide 979294 1061 0940 rev 4 0 Turn power OFF and UNPLUG the host PC and externally connected equipment prior to removing any cover plates or modules Electric shock or damage to equipment can result even under low voltage conditions Take ESD precautions packaging proper handling grounded wrist strap etc Use care to avoid touching board surfaces and onboard components Only handle boards by their edges or ORBs Ensure boards do not come into contact with foreign elements such as oils
105. the cable Note that the Clamps must be positioned over the cable s Copper Band as shown in the figure on page 4 5 Tighten screws snug but do not over tighten Note In the following figure the cable is not shown to allow for greater clarity of parts Cable Clamp 1033 2009 Cable Clamp E gt 1033 2010 i Screw 440 x 5 16 1 of 2 Grounding M Pigtail Connect Cable and Grounding Pigtail to DBK203 Note DBK204 for use with DaqBoard 2000 Series Boards consists of a DBK203 and a CA 209 CE cable kit DBK204c for use with cPCI DaqBoard 2000c Series Boards consists of a DBK203 and a CA 209c CE cable kit 1 Verify correct PA connector alignment of the CA 195CE Cable and DBK203 s P4 connector 2 Complete the connection 3 Connect the open end of the Grounding Pigtail to the threaded insert located to the right of DBK203 s P4 connector See figure on page 4 5 Note When mating P4 connectors ensure that the P4 white locator triangles VEZA PA point to each other The triangles locate pin Al wy PA At this point your board will be CE compliant providing that the conditions listed on your board s Declaration of Conformity are satisfied You can return power to the system and commence with normal operation of your DaqBoard 2000 Series or 2000c Series Board 4 6 CE Compliance 959495 DaqBoard 1000 and 2000 Series User s Manual Calibration 5 DaqBoard 1000 and 2000 Series boards are factory
106. tions 3 2 Pinouts for DaqBoard 2000 Series and 2000c Series Boards 3 8 4 CE Compliance Overview 4 1 CE Standards and Directives 4 1 Safety Conditions 4 2 Emissions Immunity Conditions 4 2 CE Enhancements for DBKSs 4 3 CE Cable Kits for DaqBoard 2000 Series and 2000c Series Boards 4 3 5 Calibration 6 Specifications DaqBoard 1000 Series Boards 7 Specifications DaqBoard 2000 Series Boards Glossary DaqBoard 1000 and 2000 Series User s Manual 889094 This page is intentionally blank xX 889094 DaqBoard 1000 and 2000 Series User s Manual DaqBoard 1000 and 2000 Series Installation This guide tells how to complete the following steps for a successful installation Step 1 Install Software page 2 Step 2 Install Boards in Available PCI Bus Slots page 3 Step 3 Configure Boards page 5 Step 4 Test Hardware page 6 Reference Note After you have completed the installation you should refer to the electronic documents that were automatically installed onto your hard drive as a part of product support The default location is in the Programs group which can be accessed from the Windows Desktop You should keep your DaqBoard s serial number and your DaqView 2000 authorization code if applicable with this document Space is provided below for recording up to 4 board numbers and their PCI bus slot loca
107. tions The board serial number is located on the connector as indicated in the following figure Serial Number xxx Serial Number Location on DaqBoard 2000 Series Connector The location is similar for DaqBoard 1000 Series Board Board Type e g Serial Number PCI Bus Slot Location 1000 1005 2000 2001 etc Boat ors Boards ports The host PC can support up to four Boards Note DaqBoards have device labels which read for example DaqBoard 1000 DaqBoard 2001 DaqBoard 2002 etc The name labels are convenient for users of more than one board type Daq View 2000 Authorization Code Customers who ordered Daq View 2000 can find their authorization code on the authorization code sheet located inside the sleeve of the install CD Note that earlier documents may refer to this as a registration code or registration ID Customers who did not order Daq View 2000 can run a 30 day free trial version as discussed elsewhere in the User s Manual Take ESD precautions packaging proper handling grounded wrist strap etc Use care to avoid touching board surfaces and onboard components Only handle boards by their edges or ORBs if applicable Ensure boards do not come into contact with foreign elements such as oils water and industrial particulate 1999 through 2004 by 898195 1033 0940 rev 8 0 Reference Notes 1 Each DaqBoard plugs into a PCI bus slot Con
108. to 1 A 8 Negative Reference Analog 5 V reference 1 A36 9 Positive Reference Analog 5Vreference 1 B35 O CH 15 SE or CH 7 LO DIFF Ch 15 HI IN single ended mode Ch 7 LO IN differential mode Ch 14 HI IN single ended mode Ch 6 LO IN differential mode Ch 13 HI IN single ended mode Ch 5 LO IN differential mode Ch 12 HI IN single ended mode Ch 4 LO IN differential mode CH 11 SE or CH 3 LO DIFF Ch 11 HI IN single ended mode Ch 3 LO IN differential mode CH 10 SE or CH 2 LO DIFF Ch 10 HI IN single ended mode Ch 2 LO IN differential mode Ch 9 HI IN single ended mode Ch 1 LO IN differential mode Ch 8 HI IN single ended mode Ch 0 LO IN differential mode Ch 6 IN single ended mode Ch 6 HI IN differential mode Ch 5 IN single ended mode Ch 5 HI IN differential mode Ch 3 IN single ended mode Ch 3 HI IN differential mode Ch 2 IN single ended mode Ch 2 HI IN differential mode Ch 1 IN single ended mode Ch 1 HI IN differential mode CH 0 SE or CH 0 HI DIFF Ch 0 IN single ended mode Ch 0 HI IN differential mode DaqBoard 1000 and 2000 User s Manual 879194 Connections amp Pinouts DaqBoard 2000 Series 3 9 P2 for DaqBoard 2000 Series and 2000c Series Boards Digital I O P2 gt amp Digital NO Port B ef E S Pins 3 thru 10 Se Fe Se FeSL The P2 DB37 connector is P uD SEE SELES obtained with the use of S E SE FIFO RIG 1 gt be E ee
109. uctive particles are permitted in the atmosphere warm up time is sufficient to avert any condensation or frost no hazardous voltages are applied until completion of the warm up period Pollution Degree II implies the expectation of occasional condensation e overvoltage installation category classification with limits for transient overvoltage dependent on the nominal line voltage to earth Category I implies signals without high transient values Category II applies to typical mains power lines with some transients Safety Conditions Users must comply with all relevant safety conditions in the user s manual and the Declarations of Conformity This manual and Daq hardware make use of the following Warning and Caution symbols If you see either of these symbols on a product carefully read the related information and be alert to the possibility of personal injury This warning symbol is used in this manual or on the equipment to warn of possible injury or death from electrical shock under noted conditions This warning caution symbol is used to warn of possible personal injury or equipment damage under noted conditions Dag products contain no user serviceable parts refer all service to qualified personnel The specific safety conditions for CE compliance vary by product but general safety conditions include e The operator must observe all safety cautions and operating conditions specified in the documentation for all hardw
110. used to configure the other three 8 bit ports for either input or output operations Local 16 bit P3 Port DaqBoard 2000 Series only For DaqBoard 2000 series devices the 16 bit P3 Digital Port can be used as either an input or an output port With this port no configuration is required as the port simply outputs when written to and inputs when read DaqBoard 1000 and 2000 Series User s Manual 889094 Daq Systems and Device Overviews 1 5 Expansion Digital I O DaqBoard 2000 Series only The DaqBoard 2000 Series boards that have digital I O capabilities have the ability to expand these through the P2 port and the connection of applicable digital I O expansion modules These modules are discussed in the DBK Option Cards amp Modules User s Manual When using the digital I O expansion modules the local P2 Intel 8255 digital I O becomes inaccessible in lieu of the expansion modules These expansion modules provide additionally Intel 8255 ports as well as input isolation for applications that require the expanded capabilities Pulse Stream Output Using Timers The boards allow the generation of output pulses based upon a programmable setting These output timers can be set at any time regardless of the state of any synchronous or asynchronous operations which are currently taking place on other channels Analog Output Channels The boards that have analog output capabilities have the ability to output analog data to any of the available u
111. ut CTRO CNT1 Counter Input CTR1 CNT2 Counter Input CTR2 CNT3 Counter Input CTR3 TMRO TMR1 Timer Output 1 XDPCR DAC Pacer Clock I O GND Digital Common N B m TTL Trigger Input Note 1 UJ WO UJ 00 m w Ww u QI P R H A m u m I UJ u NIN u Timer Output 0 m O Note 1 2 2 Connections amp Pinouts DaqBoard 1000 Series 889094 DaqBoard 1000 and 2000 Series User s Manual Pinout for DaqBoard 1000 and DaqBoard 1005 3 mba r Gi Pin numbers refer to the 68 pin SCSI III female connector located on the DaqBoard 1000 and DaqBoard 1005 boards Function SE DIFF Pin analog input che woofs analog input Jona mamas macon e analog input Jonao ciziojan analog input cus smao macon e masmu ona Hani fa macn fa Analog input Jonas msio 26 analog input Jone nomls anaogcom fa analog input cuts cH7o 23 Analog Output 0 DACO Note 1 I Analog Output I baca Morel Jar Svoc Positive Reference 20 vezes ves TJET ii 10 in 80 fa Distal 10 ine na fe ii 10 ine n fs Digital Vo ine Bo fu aome fe Distal 10 ine ga fe Digital vo ine 86 a rol vo ine co o ii vo ine ca e rol vo ine Ga e Teorin JET counter input rro T S Courier fe river Output TJERT AD Pacer Cock npuvOutput J2 DAC Pacer Cockvo TJ Note 1 DACO and DACI apply to DaqBoard 1000 DaqBoard 1000 and 12000 Series Us
112. ve the buffer b A follower stage used to drive a number of gates without overloading the preceding stage c An amplifier which accepts high source impedance input and results in low source impedance output effectively an impedance buffer An amplifier used primarily to match two different impedance points and isolate one stage from a succeeding stage in order to prevent an undesirable interaction between the two stages Also see Buffer In reference to Daq devices channel simply refers to a single input or output entity In a broader sense an input channel is a signal path between the transducer at the point of measurement and the data acquisition system A channel can go through various stages buffers multiplexers or signal conditioning amplifiers and filters Input channels are periodically sampled for readings An output channel from a device can be digital or analog Outputs can vary in a programmed way in response to an input channel signal Common mode pertains to signals that are identical in amplitude and duration also can be used in reference to signal components Common mode voltage refers to a voltage magnitude referenced to a common point that is shared by two or more signals Example referenced to common Signal lis 5 VDC and Signal 2 is 6 VDC The common mode voltage for the two signals is 5 5 VDC 5 6 2 An undesired transfer of signals between systems or system components Crosstalk causes
113. w voltage conditions The discharge of static electricity can damage some electronic components Semiconductor devices are especially susceptible to ESD damage You should always handle components carefully and you should never touch connector pins or circuit components unless you are following ESD guidelines in an appropriate ESD controlled area Such guidelines include the use of properly grounded mats and wrist straps ESD bags and cartons and related procedures Overview DaqBoard 1000 Series boards communicate external from the host PC through a 68 pin SCSI MI connector The TB 100 board is used to provide convenient screw terminal connections for all signal I O Pinouts for both the TB 100 and the DaqBoard 1000 Series boards follow Note that a TB 100 board can be easily connected to a DaqBopard 1000 or DaqBoard 1005 via a 68 conductor shielded cable p n CA G56 The cable has a length of three feet DaqBoard 1000 and 2000 Series User s Manual 889094 Connections amp Pinouts DaqBoard 1000 Series 2 1 TB 100 Terminal Connector Option The TB 100 Terminal Connector option can be used to connect all signal I O lines that are associated with a DaqBoard 1000 Series device TB 100 connects to the DaqBoard s 68 pin SCSI M connector via a shielded 3 ft 68 conductor cable p n CA G56 TB 100 Pinout The Pin column refers to the pin no on the 68 Pin SCSI III Connector 5V Vec 5 VDC ACHO GND Digital Common ACH8
114. water and industrial particulate 1 Turn the PC s power OFF 2 Turn power OFF to externally connected equipment 3 UNPLUG the host PC and all externally connected equipment 4 Remove the computer s compact PCI bus slot cover plate or remove an unwanted module if applicable Refer to your PC Owner s Manual as needed 5 Verify that the available compact PCI bus slot is for 5 volt applications The computer s 5 volt compact PCI bus slots can be recognized by a blue voltage key that is located in the center of the slot see figure 6 Carefully remove the DaqBoard 2000c Series Board from its anti static protective bag If you have not already done so write down the serial number of your board at this time The serial number is located on the 100 pin P4 connector 7 With the board s injector ejector down guide the board into the PC s slot Note that the top and bottom edges of the board locate in edge guides within the PC 8 Push the board back into the PC to engage the board s compact PCI connector with the computer s compact PCI bus slot 9 Pull the board s injector ejector up This will fully engage the connectors Installing a DaqBoard 2000c Series Board 10 Secure the board by tightening the upper and lower lock screws 11 Using the previous steps install additional boards into available compact PCI bus slots if applicable to your application Lower Lock Screw Note