Home

(xvt) user`s manual - MaxPower Corporation

image

Contents

1. 120V Model XVT 600 XVT 800 XVT 1200 XVT 1500 Voltage 94V 144V 5V INPUT Capacity VA 600 VA 800 VA 1200 VA 1440 VA W 360 W 480 W 720 W 900 W Frequency 60HZ 5Hz Voltage 105 134 VAC 120V 12 Waveform Pure Sine Wave Typical Frequency AC mode follow utility Battery mode 60 0 5Hz OUTPUT a Time 4ms Typical Protection 29 Joules Input Protection Compliance with IEEE 587 Short Circuit Breaker Battery Type Sealed Maintenance free lead acid Battery Qty amp 1 12V 1 12V 2 12V BATTERY Size 7AH 9AH 7AH 2 12V 9AH Recharge less than 10 hours to 90 capacity Backup Time 3 min full load 2 6 min 50 load Charge Current 1 5A Max Dimensions W x D x H inches Product Dimensions 3 7 x 14 6 x 6 2 4 9 x 16 9 x 8 7 Shipping si 7 T Dimensions 6 1 x 16 2 x 10 2 7 5 x 18 9 x 12 8 Product Weight 15 3 Ibs 16 8 Ibs 27 6 Ibs 31 3 Ibs PHYSICAL Shipping 17 6 lbs 1921 bs 29 8 Ibs 32 4 Ibs Weight Line Cord 6 ft NEMA 5 15P Receptacles 6 NEMA 5 15R 3 SURGE PROTECTED 3 UPS Communication USB Communications Interface Bezel Color Brushed Metallic Outer Black Inner Included in box UPSILON CD USB cable Manual Operating cand Temperature 035 C ENVIRONMENT Humidity 0 90 Audible Noise 45dB Altitude 11 500 ft 3500 m above sea level WARRANTY Warranty Two years
2. X d Xtreme Power Conversion Corporation Rev 8 29 13 Page 3 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow ALL instructions carefully during the installation and operation of the UPS Read this manual thoroughly before attempting to unpack install or operate CAUTION ro prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION 7o reduce the risk of electric shock do not remove the UPS cover Qualified Service Personnel must perform ALL repairs and maintenance No user serviceable parts inside CAUTION Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected CAUTION UPS must be connected to AC power outlet with fuse or circuit breaker protection Do not plug into an AC wall outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT xtreme Power does not sell products for life support or medical applications DO NOT use these UPS in any circumstances that would affect operation or safety of any life support equipment or with any medical applications o
3. Remove all watches rings or other metal objects Only use tools with insulated handles Do not lay tools or metal parts on top of battery or any terminals Wear protective eye wear goggles rubber gloves and boots Disconnect the charging source before connecting or disconnecting the battery terminals Qr Wr Determine if the battery is inadvertently grounded If inadvertently grounded remove the source of the ground Contact with a grounded battery can result in electrical shock The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit DEFINITIONS FOR LED INDICATORS LED 1 green LED 2 yellow LED3 red Unit Status ON OFF On AC Power OFF OFF FLASH On Battery ON Charge Overheat Overload Protection Short Circuit Xtreme Power Conversion Corporation Rev 8 29 13 Page 11 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Note means any situation LED 1 GREEN LED 2 YELLOW LED 3 RED ALARMS Alarm Indication Unit Status Buzzer every 5 sec DC start Buzzer every 1 sec Self test 2 buzzer every 1 sec Low battery 4 beep every 2 4 sec Overload 3 buzzer every 1 sec Overheat Input is off long beep power off after 5 sec Short circuit Xtreme Power Co
4. Disturbance a If XPCs evaluation provides no evidence of damage from a Power Disturbance XPC will send to the Purchaser i a report summarizing the tests performed and ii a rejection of claim notice b If the Product shows evidence of damage from a Power Disturbance XPC will request that all Connected Equipment for which a Load Protection Policy claim has been submitted be sent for evaluation to either XPC or an authorized service center If it is determined that the Connected Equipment has been damaged by a Power Disturbance XPC will in its sole discretion issue payment to the Purchaser for either the cost of repair of the Connected Equipment or the Fair Market Value of the damaged Connected Equipment up to the dollar limits stated above XPC reserves the right to require the Purchaser to transfer title and deliver the Connected Equipment to XPC if it chooses to reimburse the Purchaser for the fair market value of the Connected Equipment XPCs maximum liability shall be reduced to reflect all such other payments or sources of recovery whether applied for or not 4 IfXPC issues payment to the Purchaser to have the Connected Equipment repaired the repair must be performed at a service center that is authorized by the manufacturer of the Connected Equipment XPC reserves the right to contact the authorized service center directly to discuss repair costs and damage to the Connected Equipment to determine if it was caused by a Power Disturba
5. Prop and Ma 2 p IF Low Battery Docas Comme fi EH Enable EMal Shutdown Sequence irl E007 Emal Tima Needed for Shutdown Seguenos PERTE 2 Belew UPS Turns Oif due Sel Page Numbers and Codes FeplipwamrgMesageEvay A Sem Det Cana _ _ E M UN I Xtreme Power Conversion Corporation Rev 8 29 13 Page 10 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS REPLACING THE BATTERY QUALIFIED SERVICE PERSONNEL ONLY CAUTION Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of Qualified Service Personnel knowledgeable of batteries and their precautions CAUTION use only the specified type of battery See your dealer for replacement batteries CAUTION rne battery may present risk of electrical shock Do not dispose of batteries in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION po not open or mutilate the batteries Released electrolyte is harmful to skin and eyes and may be toxic CAUTION Although the battery system voltage is only 12VDC and 24 the battery can present a high risk of short circuit current and electrical shock The short circuit current capability of the battery is sufficient to burn wire or tools very rapidly producing molten metal Observe these precautions when replacing the battery
6. or circuit breaker and does not service equipment with large inrush electrical demands e g refrigerator copier etc Note DO NOT use extension cords or power or surge strips on the input or the output of the UPS 4 Depress the power switch to turn the UPS on The power on LED indicator and charging LED will illuminate after the UPS initial test to indicate the UPS is switched ON XL e rl Xtreme Power Conversion Corporation Rev 8 29 13 Page 7 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS 5 f an overload is detected an audible alarm will sound and the UPS will emit one long beep every 2 4 seconds To correct this turn the UPS off and unplug at least one piece of equipment from the battery powered outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on 6 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC wall outlet and there is acceptable AC voltage present the battery will automatically recharge Charging is controlled by firmware to rapidly charge units to 15VDC 600 800VA units and 29VDC 1200 1500VA units After this threshold is met the XVT places a float charge to maintain battery energy and the charging light will continue to stay on during this time 7 To maintain optimal battery charge leave the UPS plugged into an AC wall outlet with the power switch turned on at all times 8 To store your UPS for an extended period of time cover
7. the total amount of all payment s you have or are entitled to receive from insurance other warranties extended warranties a legal liability claim or from other sources or persons for the damaged Connected Equipment 5 Purchaser means the person or entity that originally purchased the Product from an authorized reseller or distributor of XPC Products The Purchaser of this Product is protected for the term of the XPC Limited Warranty against certain losses caused by a Power Disturbance for properly connected electronic equipment referred to as the Connected Equipment subject to certain terms and conditions provided below This policy applies only to the original purchaser of the Product If the Product is transferred or sold to another person or entity this policy is void Load Protection Policy Dollar and Period Limits For purchasers that meet the qualifications and conditions set forth in this policy XPC will provide reimbursement cost of repair or fair market value as determined by XPC during the period limits and up to the dollar limits stated as follows PRODUCT DOLLAR LIMIT PERIOD OF COVERAGE XVT 25 000 Term of XPC Limited Warranty XST 25 000 Term of XPC Limited Warranty XPRT 6kVA amp 10kVA 50 000 Term of XPC Limited Warranty NXRT 50 000 Term of XPC Limited Warranty P90 P9OL P90g P90Lg 50 000 Term of XPC Limited Warranty T90 50 000 Term of XPC Limited Warranty TX90 TX90i 50 000 Term of XPC Limi
8. CT FREENMAGE Power Conversion UNINTERRUPTIBLE POWER SUPPLY UPS XVT Line Interactive UPS 600VA 800VA 1200VA 1500VA Models USER amp INSTALLATION MANUAL WWVW Xpcc com 2013 Xtreme Power Conversion Corporation All rights reserved XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS TABLE OF CONTENTS PRODUCT DESCRIPTION cia nn eret cene irae ee 5 UPS eis tt eu A Mace eu ne M DA e ecc stc a Ed qe 5 Battery Surge Outlets e e M AU A RU CM MADE UE EE 6 M M Is LESE tk MM AC eta Mr PE MEE REPERTA S 6 Power ele f rtr t 6 CI CHIEBIGRKBE ta ES SUC ECA bM ATE 6 SE cana ee Rt eee re her et 6 DETERMINING THE POVVER REQUIREMENTS OF YOUR EQUIPMENT 7 HARDWARE INSTALLATION 0 7 QUICKSTART SOFTWARE INSTALLATION GUIDE FOR WINDOWS iic neci itee de nha tenis eat na C OLOR Ee iu 9 REPLACING THE BATTERY c thecninc cioe rica oekn cione s 11 DEFINITIONS FOR LED INDICATORS mme 11 ALARMS acoso o cre tae wes tee nn te et EE ION riva te state 12 TROUBLESHOOTING 13 SPECIFICATIONS ie issus scd ex ke b 14 SHIPPING GUS Essent 15 OBTAINING che hue coded eain pado duda i tie acu 16 XTREME POWER CONVERSION CORPORATION L
9. IMITED WARRANT Ms 17 EX Xtreme Power Conversion Corporation Rev 8 29 13 Page 2 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS SAFETY INSTRUCTIONS ATTENTION ro safely interact with and enjoy all the features and benefits of these Xtreme Power Conversion Uninterruptible Power Supplies UPS please read and follow all installation and operation instructions completely These UPS are designed to provide power protection for connected electronic equipment Please read this manual before installing the XVT Series UPS models XVT 600 XVT 800 XVT 1200 and XVT 1500 as it provides important information that should be followed during installation and maintenance of the UPS and batteries allowing you to correctly set up your system for the maximum safety and performance Included is information on customer support and factory service if it is required If you experience a problem with the UPS please refer to the Troubleshooting section in this manual to correct the problem If the problem is not corrected please collect information so that the Technical Support personnel can more effectively assist you CAUTION Any changes or modifications not expressly approved by the manufacturer of this device could void the user s authority to operate the equipment FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These lim
10. MENT FACILITIES OR SERVICES DOWNTIME THE CLAIMS OF THIRD PARTIES INCLUDING CUSTOMERS AND INJURY TO PROPERTY Submitting a Load Protection Policy Claim 1 Any claim under the Load Protection Policy must be made within 10 days of the date of alleged damage to the Connected Equipment 2 Call the XPC technical support department at 1 800 582 4524 and obtain a Load Protection Policy Returned Material Authorization RMA number Have information on all applicable insurance or other resources of recovery payment that is available to the Purchaser and the name of the power utility supplier for the location of the Connected Equipment XPC will forward to the Purchaser a Load Protection Policy claims form which must be completed and filed with XPC within 30 days a Markthe Load Protection Policy RMA number on the Product the Purchaser is returning b Packthe Product in its original packaging or similar packing materials if the original packaging has been discarded Enclose the completed Load Protection Policy claim form and a copy of the Purchaser s original sales receipt for the Product in the box Mark the RMA number clearly on the outside of the box d Ship the Product one way shipping charges paid by the Purchaser to XPC Corporation 230 Yuma Street Denver CO 80223 Attn LPP RMA 3 will evaluate the Product to determine its level of functionality and will examine the Product for evidence of damage from a Power
11. Power Conversion XPC Corporation warrants Xtreme Power Conversion equipment when properly applied and operated within specified conditions against faulty materials or workmanship excluding batteries for a period of two years for XVT Series products from the date of purchase XPC Corporation warrants internal batteries for a period of two years from the date of purchase For equipment sites within the United States and Canada this warranty covers repair or replacement at the sole discretion of XPC Corporation The customer is responsible for the costs of shipping the defective product to XPC Corporation XPC Corporation will pay for ground shipment of the repaired or replacement product This warranty applies only to the original purchaser If equipment provided by XPC Corporation is found to be Dead on Arrival DOA XPC Corporation will be responsible for the costs of shipping product to and returning equipment from the customer in a timely manner as agreed to with the customer once the customer has requested and received a Return Material Authorization RMA number DOA equipment is defined as equipment that does not properly function according to user documentation when initially received and connected in conjunction with proper procedures as shown in the user documentation or via support provided by XPC Corporation personnel or authorized agents This warranty shall be void if a the equipment is repaired or modified by anyone other than XPC Cor
12. Silon 2000 for Windows 1 cat DupaVolkege Batey Char UFS Load selec UPS upd Charge Kx E Deis Log UPS Manulachagsiidanmen Kehua Z SCR s UPS Hodel non Qi UPS Version VER10 Event Lo LPS Sal Tes 2003 03 20 15 07 06 UPS Connected C C MINI 1547 00 1 EE C Ml Tact in Proms Section 1 is the UPS Dynamic Display Area where relevant information regarding the UPS is displayed Selection of different display modes is possible with information including input voltage output voltage line frequency battery capacity load temperature etc Section 2 is the UPS Status Area shows whether the UPS is connected to the computer if AC power is in normal range status of the UPS and relevant information regarding the UPS Section 3 is the Function Selection Area allows configuration of the parameter values After selecting to monitor Local UPS computer shutdown sequence and automatic shutdown time parameters can then be programmed General Setting c Computer Shutdown Sequence Settings Communication Type ec F QohonslCommandFie lo Execule Browse b F SuloSaye Application fe Shutdown Operating System F OW UPS Select Comm Port cow 1 gt Pout M BecaduFS Data P Display Dored Record on UPSdon Restat Interval n Sece E Brosicat Seltings Shulidonn Time Petemeters 2 PooUp serge Alter fo BH pce Sud
13. and store it with the battery fully charged Recharge the battery every two months to maintain battery life Xtreme Power Conversion Corporation Rev 8 29 13 Page 8 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS QUICKSTART SOFTWARE INSTALLATION GUIDE FOR WINDOWS 1 Locate the USB Cable inside the box 2 Insert one end of the USB Cable into the UPS and the other into a USB port on your computer 3 Insert the CD into your computers CD drive 4 UPSilon 2000 will display the installation menu or you can select run from windows start menu and execute setup exe UPSilon files will be copied into the directory you appoint 5 Follow the software setup prompts 6 When UPSilon has been launched the operating system will select the local language for displaying UPSilon 7 Select UPSilon 2000 for Windows for parameter settings Click Select UPS to monitor local or remote UPS Select Settings to set Communication Type and Select Comm Port If Communication with UPS is on the main screen then you have connected to the UPS UPSilon 2000 is a smart UPS monitoring and control software UPSilon displays the status of the UPS in digital and graphic modes which will enable the user to monitor the UPS Xtreme Power Conversion Corporation Rev 8 29 13 Page 9 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS Functions After entering UPSilon a functional chart displays as below uP
14. ed by this Policy 1 Restoration of lost data and reinstallation of software 2 Damage from a cause other than AC power line transients except for damage due to telephone line Local Area Network or CATV transients which is covered only if the Product offers such protection 3 DAMAGE CAUSED BY FAILURE TO PROVIDE A SUITABLE INSTALLATION ENVIRONMENT FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO LACK OF A PROPER SAFETY GROUND Damage caused by the use of the Product for purposes other than those for which it was designed Damage caused by accidents or natural disasters including but not limited to fire flood and wind Damage caused by abuse misuse alteration modification or negligence Any labor costs or travel room and board expenses associated with the repair and or restoration of lost or damaged hardware software or data EXCEPT AS EXPRESSLY PROVIDED IN THIS POLICY XPC SHALL NOT BE LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO DIRECT INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL OR MULTIPLE DAMAGES ARISING OUT OF THE USE OF THE PRODUCT OR DAMAGE TO THE CONNECTED EQUIPMENT REGARDLESS OF THE LEGAL THEORY ON WHICH SUCH CLAIM IS BASED EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE SUCH DAMAGES INCLUDE BUT ARE NOT LIMITED TO LOSS OF PROFITS LOSS OF SAVINGS OR REVENUE LOSS OF USE OF THE PRODUCT OR THE CONNECTED EQUIPMENT OR ANY ASSOCIATED EQUIPMENT LOSS OF SOFTWARE COST OF CAPITAL COST OF ANY SUBSTITUTE EQUIP
15. electronics Two year batteries APPROVALS North America UL cUL FCC INDICATORS amp ALARMS AC Mode Green LED on Orange LED on Red LED off no beep Charging i Ene Battery Orange LED on until 80 charge Battery Mode Green LED and Orange LED off Red LED flash buzzer slow beep Battery Low Green LED and Orange LED off Red LED on buzzer fast beep Xtreme Power Conversion Corporation Rev 8 29 13 Page 14 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS SHIPPING LIST 1 1 UPS 1 User s and Installation Manual 1 Intelligent monitoring software 1 USB computer port cable 009 9 Xtreme Power Conversion Corporation Rev 8 29 13 Page 15 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS OBTAINING SERVICE If the UPS requires Service 1 Usethe TROUBLESHOOTING section in this manual to eliminate obvious causes Verify there are no circuit breakers tripped 3 Call your dealer for assistance If you cannot reach your dealer or if they cannot resolve the problem call Xtreme Power Conversion Corp Technical Support at 800 582 4524 Technical support inquires can also be made at support xpcc com Please have the following information available BEFORE calling the Technical Support Department a 5 Your name and address The serial number of the unit Where and when the unit was purchased All of the model information about your UPS Any information on the failure includin
16. g LED s that may or may not be illuminated A description of the protected equipment including model numbers if possible A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization number If you are returning the UPS to Xtreme Power for service please follow these procedures 1 4 Pack the UPS in its original packaging If the original packaging is no longer available as the Technical Support Technician about obtaining a replacement set of packaging material It is important to pack the UPS properly in order to avoid damage in transit Never use Styrofoam beads for a packing material Include a letter with your name address daytime phone number RMA number a copy of your original sales receipt and a brief description of the problem Mark the RMA number on the outside of all packages Xtreme Power cannot accept any package without the RMA number marked on the outside of the boxes Return the UPS by insured prepaid carrier to the address provided by the Technician Refer to the Warranty statements in this manual for additional details on what is covered Ux Asc T Xtreme Power Conversion Corporation Rev 8 29 13 Page 16 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS XTREME POWER CONVERSION CORPORATION LIMITED WARRANTY Xtreme
17. ilure Power Switch Can be used as a master on off switch for equipment connected to the battery powered outlets Power On Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing power free of surges and spikes Circuit Breaker The circuit breaker that provides overload and fault protection USB Port protocol that provides communication between the UPS and PC Network H1 Xtreme Power Conversion Corporation Rev 8 29 13 Page 6 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS DETERMINING THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Make sure the total Volt Amp VA requirements of your connected equipment does not exceed the maximum VA rating for the UPS The maximum VA ratings are shown in the Specifications section of this document 2 Ensure that the equipment plugged into the battery powered outlets does not exceed the UPS rated capacity If UPS rated capacities are exceeded an overload condition may occur and cause the UPS to shut down and trip the circuit breaker 3 If the power requirements of your equipment are listed in values other than Volt Amps convert Watts W or Amps A into VA by doing the calculations below Note The equation below only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any given time Use
18. its are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications There is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced technician for help Any special accessories needed for compliance must be specified in the instruction CAUTION A shielded type power cord is required in order to meet FCC emission limits and to prevent interference to the nearby radio or TV reception It is essential that only the supplied power cord be used Use only shielded cables to connect 1 0 devices to this equipment CAUTION Any changes or modifications not expressly approved by the manufacturer of this device could void the user s authority to operate the equipment aX LR
19. nce and the right to request that the service center forward the Connected Equipment or components of the Connected Equipment to XPC for inspection 5 Unless modified in writing signed by an officer of XPC and the Purchaser the terms of this policy are the complete and exclusive agreement between the parties superseding all prior agreements oral or written and all other communications between the parties relating to the subject matter of this agreement No employee of XPC or any other party is authorized to make any representations beyond those made in this agreement concerning the Load Protection Policy XPC Corporation 230 Yuma Street Denver CO 80223 1 800 582 4524 n EXER X 2 rl Xtreme Power Conversion Corporation Rev 8 29 13 Page 19
20. nversion Corporation Rev 8 29 13 Page 12 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS TROUBLESHOOTING PROBLEM POSSIBLE CAUSE Full time surge protection outlets stop providing power to equipment Circuit breaker has tripped due to an overload Battery not fully charged The UPS does not supply SOLUTION Turn the UPS off amp unplug at least one piece of equipment Wait 10 sec replace the fuse with a fuse of like size amp rating amp turn the UPS on Recharge the battery for at least 4 hours expected runtime The battery is defective Contact Xtreme Power Conversion about replacement of batteries The on off switch is designed to prevent damage by rapidly turning it off and on Turn the UPS off Wait 10 sec amp then turn the UPS on The UPS is not plugged into an AC The UPS will not turn on wall outlet Connect the UPS to an 110 120V 60Hz AC wall outlet The battery is defective Contact Xtreme Power Conversion about replacement of batteries Mechanical problem Contact Xtreme Power Conversion The UPS shuts down when The UPS is not providing battery there is loss of AC power power Shutdown your load amp turn the UPS off Wait 10 sec amp turn the UPS back on This should reset the UPS Xtreme Power Conversion Corporation Rev 8 29 13 Page 13 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS SPECIFICATIONS
21. poration or a XPC Corporation approved third party b the equipment is damaged by the customer is improperly used or stored is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications or c the equipment has been used or stored in a manner contrary to the equipment s operating manual intended use or other written instructions Any technical advice furnished by XPC Corporation or a XPC Corporation authorized representative before or after delivery with regard to the use or application of Xtreme Power Conversion equipment is furnished on the basis that it represents XPC Corporations best judgment under the situation and circumstances but it is used at the recipient s sole risk EXCEPT AS STATED ABOVE XPC Corporation DISCLAIMS ALL WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCEPT AS STATED ABOVE IN NO EVENT WILL XPC Corporation BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF Xtreme Power Conversion EQUIPMENT including but not limited to any costs lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data cost of substitutes or claims by third parties Purchaser s sole and exclusive remedy for breach of any warranty expressed or implied concerning Xtreme Power Conversion equipment and the only obligation of XPC Corporation
22. r patient care NOTICE wot for use in a computer room as defined in the Standard for Protection of Electronics Computer Data Processing Equipment NOTICE an acceptable outlet based upon UPS Specifications shall be installed near the equipment and shall be easily accessible c Xtreme Power Conversion Corporation Rev 8 29 13 Page 4 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS PRODUCT DESCRIPTION L RELAY RELAY U INPUT OUTPUT RELAY gt UPS Functionality The XVT UPS products use Line Interactive Automatic Voltage Regulation AVR UPS technology Under normal AC power operation the input power flows through the AVR circuit regulating the incoming AC power to the output of the UPS and the load connected If the input power disappears the Inverter circuit is switched on to provide output from the batteries contained within the UPS POWER ON OFF AC MODE GREEN LED CHARGE MODE YELLOW LED BATTERY MODE RED LED XVT FRONT PANEL Xtreme Power Conversion Corporation Rev 8 29 13 Page 5 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS USB Connector 3 Battery Protected Outlets 3 Surge Only Outlets 6 Foot Power Cord Input Breaker XVT REAR PANEL Battery Surge Outlets Provides battery powered surge outlets for the connected equipment and insures uninterruptible operation of your equipment during a power fa
23. rs should expect usage requirements to be approximately 6096 of the value to estimate power requirements Watts W x 1 67 VA or Amps A x 120 VA Add the totals for all of the equipment and multiply this total by 0 65 to calculate actual power requirements Note Many factors can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 8596 of the UPS capacity HARDWARE INSTALLATION GUIDE 1 Your new UPS may be used immediately upon receipt however charging the battery for at least 4 hours is recommended to ensure that the batteries maximum charge capacity is achieved Charge loss may occur during shipment and storage To recharge the battery plug the power cord into the correct type AC wall outlet and turn the power switch on Note Xtreme Power units will charges the battery with the power switch in either the on or off position 2 With the UPS off and unplugged connect your computer monitor and or any other externally powered equipment into the battery power supplied outlets DO NOT plug a laser printer copier space heater vacuum or other large electrical device into the UPS The power demands of these devices will overload and possibly damage the UPS 3 Plug the UPS into a 2 pole 3 wire grounded receptacle AC wall outlet as rated in the Specifications section of this document Make sure the wall outlet is protected by a fuse
24. t have been damaged by a Power Disturbance on a properly installed grounded and National Electric Code NEC code compliant 120 208 240 Volt AC power line in the United States or Canada by a Power Disturbance on standard telephone land line or PBX telephone equipment line that is properly installed and connected to an RJ11 port on the Product or by a Power Disturbance on a standard Local Area Network connection that is properly installed and connected to an RJ45 port on the Product and d is directly plugged into and properly connected to the Product in its original condition which was properly operated when a Power Disturbance passed through the Product and i exhausts the protection capacity of the Product or ii damages the Product The Load Protection Policy does not apply if the Product has been operated in a failure mode or not in compliance with XPC operating instructions in the Product user s manual or if the Connected Equipment has not been operated in compliance with the instructions and manuals of its manufacturer vendor This policy is null and void if XPC determines in its sole discretion that the Product has been tampered with or altered in any way What is Not Covered Under the Load Protection Policy tz c oen a ee Xtreme Power Conversion Corporation Rev 8 29 13 Page 18 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS The following damage is not cover
25. ted Warranty This Load Protection Policy is not deemed first dollar coverage 5 obligation is reduced by any amounts that the Purchaser is entitled to recover from other sources regarding the Connected Equipment including but not limited to insurance other warranty extended warranty or legal liability regardless of whether or not the Purchaser makes a claim for recovery Eligibility for Coverage Under the Load Protection Policy 1 The Product must be registered the XPC website www xpcc com within 10 days of purchase All required information must be provided and Purchaser should retain a copy for Purchaser s records When registering on the website Purchaser must list all connected equipment that is directly connected to the product Only those devices registered in that manner will be covered All Connected Equipment must be UL or CSA approved The Product must be plugged into a properly wired and grounded outlet Use of input surge devices extension cords adapters ground wires or electrical connections not manufactured by XPC voids the XPC Load Protection Policy No other surge protection device may be connected to the output sockets of the Product The installation must comply with all applicable electrical and safety codes set forth pursuant to the NEC The Product must have undeniable physical evidence of a Power Disturbance that directly and proximately caused the damage The Connected Equipment mus
26. under this warranty shall be the repair or replacement of defective equipment components or parts or at XPC Corporations sole discretion refund of the purchase price or substitution of an equivalent replacement product Ux X O Xtreme Power Conversion Corporation Rev 8 29 13 Page 17 XVT USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS XTREME POWER CONVERSION LOAD PROTECTION POLICY THIS POLICY IS NOT A WARRANTY REFER TO THE XPC CORPORATION INC LIMITED WARRANTY FOR INFORMATION CONCERNING THE WARRANTY FOR YOUR XPC PRODUCT THE LIMITATIONS AND CONDITIONS CONTAINED IN THIS POLICY DO NOT AFFECT THE TERMS OF THE XPC LIMITED WARRANTY Definitions 1 Product means a Standard 120 208 or 240 Volt power protection device that is used in the United States and Canada This policy does not include custom manufactured products 2 Power Disturbance means an AC power line transient telephone line or Local Area Network if applicable spike or surge 3 Connected Equipment properly connected electronic equipment 4 Fair Market Value of damaged Connected Equipment as determined by XPC shall be the lower of a the average price the same or similar items are being sold for on eBay b the price list of Orion Blue Book or if such price list is no longer published a published or announced price list reasonably selected by XPC c the lowest price the same or similar items can be purchased for in the United States or d

Download Pdf Manuals