Home
MANUAL - Ny side 2
Contents
1. 25 8 1 FIELD OF 25 8 2 FEED PIPE 25 8 3 CHANGE OF FEED 26 8 4 ADJUSTMENT FOR COMPONENT 44444444488 8 27 8 5 ROUND PULL DRIVE 29 8 6 02 555 31 8 7 SKIOLD RETURN VALVES 32 8 8 FEEDING VALVE WITH FEEDBACK 5 42 33 8 8 1 General Technical 33 8 8 2 User instructions and 33 6 8 3 34 920 42 Eres crm 34 8 8 5 Guidance for mounting the 35 rm 37 8 9 MOUNTING OF MIDDLE INLET IN CONNECTION WITH RESIDUE SILO 38 8 10 CONNECTION FROM FLEX AUGER TO TRANSPORK ener eene eminere nennen nennen 39 8 11 OPERATION AND TROUBLE SHOOTING eene enne keke ke kek Keke enne ke KA K KA KEKE KA KA teni KA KAKA 40 981 000 692 Part 2 3 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 445 99 89 88 87 Fax 45 99 89 88 77 es KI L LJ 9 Ma
2. Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD Example 1 Three 8 litres volume dispensers are set on 4 litres total 12 litres 2 The three portions weigh 2 75 2 91 2 85 kg 8 51 kg 3 Average weight 8 51 kg 12 litres 0 71 kg litre 4 Ata wanted quantity of 3 2 kg per feeding the volume dispenser is set on 3 2 kg 0 71 kg litre 4 51 litres 10 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD Example of trickle feeding 1 Three 8 litres volume dispensers at trickle feeding 11 litres content adjusted on 6 litres total 18 litres 2 Weight of the three portions 4 50 4 12 4 37 kg 12 99 kg 3 Average weight 12 99 kg 18 litres 0 72 kg litres 4 At a required quantity of 6 4 kg per feeding adjust the volume dispenser to 6 4 kg 0 72 kg litre 8 89 litres 6 6 3 Release The feed portion is released by turning the release arm on top of the dispenser In most cases the release arms are linked together in order to release several volume dispensers simultaneously The construction of the release system is described elsewhere in this manual When the feed is to be released manually you pull the handle slightly until the pawl tilts enabling it to pass the lock plate Release the feed slowly in order to avoid accumulation in the pipes When the volume dispensers close take care that the p
3. Fax 45 99 89 88 77 S KI r L LJ In order to facilitate assembly of the drive shafts one of the ends at the assembly of two shafts ought to be shortened 8 10 cm from a cellular dispenser The drive shafts can profitably be chamfered at the ends Fig 58 EJ Fig 58 Shortening of drive shaft NB In order to facilitate service it be recommended to mark up the joints During installation of cellular dispensers it is important that the various dispensers are supported correctly by supporting the protection pipe for drive shaft There must be a support at every third dispenser at distances under 75 cm and at every second dispenser at distances over 75 cm This support can either be undertaken with wall armature on wall or with wall armature mounting iron on cleaning wall pen partition Suspension iron can also be used for trickle feeding where other things are not possible or double U iron at stanchion for feed pipe see Fig 59 s il i rh dh SARI Fig 59 Suspension of protection pipe ez At the end that shall be connected to the next drive shaft the entire unit is rocked into position and the
4. The hand wheel is re tightened when the yellow indicator reaches the red line By constantly keeping an eye on the indicator you will have an impression of the present wire tension Tightening on the hand wheel can be carried out many times but when the indicator is so far away from the cabinet of the drive unit that the wide red area on the scale can be seen the feeding wire must be shortened 2 Fig 49 Indicator on the side of the drive unit 981 000 692 Part 2 7 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 KI Car L 6 5 Indicator and tightening of the feeding wire MiniPork drive unit The side of the drive unit is equipped with an indicator Pos 2 fig 49A where the wire tension can be watched continuously The wire tension can be adjusted by turning the handle pos 1 fig 49A The spring is tightened until the handle almost entirely covers the green area on the indicator The wire will stretch during operation but as long as the indicator moves in the green area an adjustment is not necessary The handle is re tightened when the indicator reaches the red area By constantly keeping an eye on the indicator you will have an impression of the present wire tension Tightening of the handle can be carried out many times but when the tension wheel Pos 3 fig 49A reaches the back of the housing the wire must be shortened Fig 49A Wire tension in
5. 0 kereke ke keke kek keke keke kK KA KA KA 14 6 10 MINIPORK DRIVE UNIT kude a tay nnn kun z ki n k W n n 15 6 11 REPLACEMENT OF BREAKING PART u ne e e ene n nnn KE KE KE KE KE KE KE KE KE KE KA 15 6 12 LOCATING FOREIGN BODY IN THE SYSTEM 800 keke ke ke ke ke KE KE KE KE KE KE KE KE KE KE KE KE KE KA 16 6 13 OPENING FOR MEDICINE e nennen nnne keke keke keke KEKE KE E KE KE KE KE KE KE KE KE KE KE HEKE KE KE KE KE KE KE KE KE KAR 16 6 14 CLEANING INSIDE INSPECTION OF THE VOLUME DISPENSER 2 16 O 15 gt TFROUBLE SHOOTING wescevssciesssceasvescicnsedudes MM AJA NE nEE HEEE MM MMI IEIMMIMDDD 17 7 Trickle feeding a kk kk kk k kk kk kk kk kk KK KK kk kk kk 18 7 1 FIELD OF APPLICATION ke Vu d l ke ka der ey yad cak y 18 7 2 INSTALLATION OF TRICKLE FEEDING SPECIAL PARTS s cccscssssececsssseeeceeseeeceesssseceessaeeeeeees 19 7 2 1 Installation of gear motor drive ease kaka kaka kaka ka keka k Kaka KA KA AA kK KA 19 7 2 2 Installation of cellular dispenserS z 20 7 2 3 Installation of down pipe L L c L L L L LLEE 22 7 3 nd WMWON orw owreaa o3op a 23 7 4 rena EU DD Het 24 e
6. 6 3 Adjusting the hopper transparent cover The hopper is fitted with an 100mm auger with 100mm pitch The amount of feed dosed into the feed pipe is constant and NOT adjustable The motorized hoppers are fitted with a geabox suited for the dimension of the feed pipe 50 8 260 0 and 063 5 The movement of the vibrator plate can be adjusted by moving the small nylon wheel driven by the auger Remember to remove foreign objects from the stone separator in order to avoid clogging Please be aware that the throttle in the silo must be closed when blowing feed into the silo This helps to avoid the feed jamming in the hopper 6 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L 6 4 Indicator and tightening of the feeding wire Transpork drive unit The side of the drive unit is equipped with an indicator where the wire tension can be watched currently without having to dismantle the front plate The indicator consists of a blue C profile pos 1 Fig 49 with coloured scale A yellow indicator pos 2 Fig 49 slides inside the profile As described in a previous section the wire tension is adjusted by turning the hand wheel pos 3 Fig 49 until the yellow indicator is flush with the end of the blue C profile The feeding wire will stretch during operation but as long as the indicator moves in the green area an adjustment is not necessary
7. gear motors do not operate Motor protection not disconnected Check that all systems are correctly mounted and possible breakages on the systems Material falls out Replace flaps 24 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 8 Phase feeding 8 1 Field of application With Transpork phase feeding system you can feed up to three mixtures in the same pipeline The system consists of the same components as an ordinary feeding system However each feed outlet can be adjusted to feed the required type of feed and below the silos motor hoppers flex augers are installed When feeding is initiated the component exchanger is set to position 1 Then all feed outlets are opened where feed type 1 is to be fed Then the drive unit and the motor hopper under silo 1 start The feeding continues until the stop sensor on the pipeline is activated and via the preset empty running time the pipeline is emptied When empty running time has ended the component exchanger goes to the position of the next active feed type and the feeding cycle starts again with the next feed type See description of operation and feed cycle in manual for phase feeding control 8 2 Feed pipe When mounting feed outlets it must be secured that the phase feeding throttle has enough room for moving meaning distance to the corners and pipe hangers Fig 64 You can possibly mount the
8. machinery in which this partly completed machinery is to be incorporated has been declared in conformity with all relevant health and safety requirements according to 2006 42 EC and other relevant directives Title Managing Director Name Samuel W Andreasen m Company SKIOLD A S Ikast date 01 05 2009 Signature 982 003 200
9. shortened to fit to the valve after which it is mounted with the joint After ended mounting the valve must be suspended correctly with minimum one fitting per valve It is possible to mount switches for indication of actual position Fig 74 2 Fig 74 Draft of SKIOLD valve 32 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 8 8 Feeding valve with feedback signal 8 8 1 General Technical Data The electric valve is available in 2 versions for tube diameter 50 8mm and 63 5mm Power supply is 24VDC Both versions have the same mechanical construction The control print is delivered with Feedback signal at activity of the valve The drive motor is equipped with a multi fuse Electrical valve with feedback 7 wire Feeding power Control U 24VDC U 24VDC luni 100mA Unloaded 15mA Iblock 800mA Motor blocked lo 5mA Motor standing still valve closed Led is red lo 14mA Motor standing still valve open Led is gren t 3sec Reactiontime open closed position In order to operate the valve in the open position the valve has to be supplied with control power during the entire open position period Connection Data Description
10. single push on the button makes the actuator return to its starting position again If disconnecting of sections is needed e g because they are empty this is made by turning the switch until the control lamp is turned off So the actuator in question is disconnected from the automatic feeding cycle but can still be operated manually with the push button The position of the actuator is constantly surveyed by the MultiPork control so that it is not possible to fill volume dispensers with feed if they are in open position 6 7 Remote operation The volume dispenser can be remote operated via a rod so that the quantity regulation can be done while walking behind the animals see Fig 51 SS mmnm Fig 51 Remote operation 981 000 692 Part 2 13 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 KI r 6 8 Disconnecting of feed release If a feed portion should not be released from a volume dispenser it is possible to disconnect same by pulling the lock out of the release arm and then turning the arm down into the release protection Fig 52 When the volume dispenser should be re connected press the release protection above the arm so that it is disengaged and the lock can be re pressed into the release arm Alternatively set the bottomflap lock to closed position so that the bottomflap stays up Fi
11. 7 S KI Car L Fig 76 Support of Multiple Feedvalves e The conveyor pipes have to be sawed squarely and the burrs have to be removed however do not round off Fig 77 1 After sawing with burrs 2 Burrs removed wrong 3 Not sawed squarely 4 Correct a p Hs J ee er 5 Fig 77 Sawing of Conveyor pipes e Do not assemble the connection cable of the valve too tight e Never connect the cable on the valve itself e Make sure that the connection boxes in the housing are waterproof 36 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 SIKISGLD 8 8 6 Connection diagram Ajddns JaMog 2 OND 01134 6 044u05 N SHUM 8 pelg S 7 dum 90 IN pepsi Jsnig rig m ON 6 elAV WAS Ajddns Jamad umolJg 0 JOA e Cu IM 37 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby n Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L 8 9 Mounting of middle inlet connection with residue silo The cover Fig 78 is used at proportioning of pelleted material At proportioning of granulated material the cover must be removed if the problem occurs that the material is stuck in the silo Fig 78 Installation of intermediary inlet in connection with
12. 9 89 88 77 em 2 Fig 70 A Opening direction for wire system B Phase feeding throttle C Piano wire e Fig 71 Installation of phase feeding throttle piano wire o o a Fig 72 Installation of turnbuckle 30 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 8 6 Residue silo For the remaining feed in the feed pipes after finished feeding sequence the system can be equipped with residue silo This can either be mounted with its own flexible auger for emptying or it can be mounted together with the silo as first inlet on the flexible auger of the silo where is used a flexible auger for filling of the feed system Fig 73 d 4 A Return valvel E B Residue silo C Silo D End inlet flex auger E Intermediary inlet flexible auger F Inlet for feed line am ri Fig 73 Draft over residue silo 981 000 692 Part 2 31 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L 8 7 SKIOLD return valves The valve is always placed above the residue silo At outdoor mounting the connection to the residue silo must be tightened with silicone and you can with advantage use rain cover for the valve The feed pipe must be
13. Colour Function Feeding power Green GND Brown 24 VDC Feedback signal Blue C contact Grey NC Pink NO Control Yellow ND White 24 VDC 8 8 2 User instructions and Maintenance Please Note Always disconnect the power before maintenance or repairs Never Place hands or fingers inside the valve nor disassemble the valve before the power is disconnected During the first days of using the valve check on a regular basis if the electric valve turns well Also check regularly if the tubes of the transport system are still horizontal The electric valve is when used normally maintenance free Please note Never clean the valve with water under high pressure Also never spray water in the opening of the valve 981 000 692 Part 2 33 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 SKISL D 8 8 3 Reset the Multi fuse To protect the drive motor a multi fuse is placed in the switch If the charging rate of the motor is too high probably caused by blocking of the rotating bush the fuse will activate To reset the multi fuse the power has to be switched off Then the cause of the blocking has to be removed and the power can be switched on The valve is now in working order again Check the working of the valve 8 8 4 Troubleshooting Problem Possible cause 1 The electric valve does not function No power The switch is not activated There is no signal from the compute
14. SKIOSL D SKIOLD MAKES A DIFFERENCE TRANSPORK DRY FEEDING SYSTEM 050 8 063 5 MM PART 2 USER MANUAL 981 000 692 Ver 7 00 23 04 2013 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 SKISLD Contents 6 Instruction Manual siete ria or Fa b rera b eon Ee a b KA KA KK 5 6 1 START STOP OF SYSTEM 3 6 2 ADJUSTMENT OF 000 4460 1 618 00800000000000000000 H nenne 5 6 3 ADJUSTING THE HOPPER TRANSPARENT 201 2 00 0 0000 0 6 6 4 INDICATOR AND TIGHTENING OF THE FEEDING WIRE TRANSPORK DRIVE UNIT 7 6 5 INDICATOR AND TIGHTENING OF THE FEEDING WIRE MINIPORK DRIVE UNIT 8 6 6 OPERATION OF VOLUME DISPENSERS 2 0 0 1 0 0000 0111100000000000000000000 9 se grng 9 6 6 2 Control cupi E qer anjl aa 9 6 62 22 12 11 6 6 4 Automatic release Model 2007 11 6 6 5 Automatic Release Model 2007 and fletu seit taret ttti Eat 12 6 7 REMOTE OPERATION RC 13 6 8 DISCONNECTING OF FEED RELEASE 422 2422420222000000000000000000000005000008 000 14 6 9 SAFETY SYSTEM OF THE TRANSPORK DRIVE UNIT 0
15. als via the release When the volume dispensers are again closed the feed plant starts to fill up the volume dispensers for the next feeding It is also possible to release the feed manually via the release controller In an ordinary operating situation the release slowly opens the volume dispensers in order to reduce the risk of bridge building in the hopper The dispensers are kept open during 10 seconds before they are closed again and the plant starts filling up again to make the dispensers ready for the next feeding On the control for section wise feed release this situation is indicated by reversing switch in vertical position and control lamp lightening Switch in stop position e Push button The release can be operated manually via the push button to function in open or closed position e g for control of the release system The manual operation can also be used if itis wanted to release the feed before the set feeding time to have more time for adjusting the volume dispensers before filling them again 12 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 es ICI r L LD The manual sequence of programs is so that pushing once the push button makes the actuator going forward to the end stop Here it waits 10 seconds before reversing and going back If the button is maintained in pushed position until the actuator is at the end the actuator remains here One
16. awl locks correctly so that the feed is not released involuntarily 6 6 4 Automatic release Model 2007 and before In systems with automatic release a feeding sequence starts when the filled volume dispensers via the release are emptied into the animal troughs Then the system starts to fill up for the next feeding However on automatic feed release start of system it is possible to release the feed manually on the release control before the preset time in order to have a little more time to adjust The release opens the volume dispensers slowly step by step to avoid accumulation in the hopper The dispensers are kept open for 5 minutes before they re close and the system re starts the filling so that the dispensers are filled for the next feeding The release can be operated manually via the buttons pos 3 and 4 fig 47 to run in open or closed position e g for control of the release system The manual operation can also be used if you want to release the feed before the automatics in order to get a longer time for adjustment of the volume dispensers before they are re filled It is a demand that the release is returned before the automatics start the next feeding as else the controller will give alarm The release is mounted with a control switch in each outer position so that it is possible to check whether the volume dispensers open or close as they must The return switch pos 5 Fig 47 must be activated when the volume dispen
17. der not to collide with this Fig 71 Also the wing nut shall turn upwards here where with advantage you can mount it downwards at ordinary phase feeding outlets NB Do not forget to place a lock nut on the bolt so that the wing nut does not fall off during cleaning The steel pipes MUST be degreased before the label is added Re adjustment between the various feed mixtures takes place when the component exchanger is in neutral position where the phase feeding throttle is then placed so that the wing nut is standing at the required feed mixture The system must be constructed in such a way that the drive on the phase feeding throttles has the same degree in order to reduce the necessary tractive effort At phase feeding the system rollers must always be installed on wall in order to ensure stability at the round pull drive The system must be designed with piano wire on all straight distances meaning that there should only be used system at the system rollers in order to reduce the necessary re adjustment Do not forget turnbuckles on EACH row Fig 72 At mounting at corner wheels and through walls there shall be at least 200 mm from corner wall to wire lock in order for the system to be able to move Further directives for erection of release system see directives for releaser system for volume dispensers 981 000 692 Part 2 29 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 SIKISGLUD Fax 45 9
18. dicator of the MiniPork drive unit 8 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 6 6 Operation of volume dispensers 6 6 1 Operation Opening the throttle placed just under the transport pipe starts filling of feed into the volume dispenser The quantity to be filled into the dispenser is regulated by dislocating the telescope up or down via the operation handle on the dispenser The best regulation is made when the dispensers are empty and before the feed system is restarted The quantity is read on the litre scale by flushing the lower side of the blue triangular marking in connection with the replaceable telescope see Fig 50 Fig 50 Reading of scale 6 6 2 Control weighing It is very appropriate to control weigh frequently and always in connection with change of feed type to be sure that the feed quantity corresponds with the expected A certain deviation must be expected because the angle of slide of the feed can vary much depending on the feed type In order to determine the specific weight of the feed type three volume dispensers placed in the middle of the system are adjusted to a number of litres corresponding to half full The feed system is started until the bins are filled The three portions are emptied and weighed The weight is found in kg per litre 981 000 692 Part 2 9 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby
19. e are different procedures for start stop of the system depending on the type of controller used Follow the procedure in the controller manual 6 2 Adjustment of hopper When filling feed into the system you must adjust the hopper so that the filling of the pipes is done correctly The filling is adjusted by adjusting the handle under the hopper pos 1 Fig 48 After loosening the handle it is pushed slowly from pos min towards max until you get a filling of 50 60 When the adjustment is satisfactory re tighten the handle Be aware that the proportioning cannot be closed completely and that the adjustment can only be altered while the system is operating in order to secure against over filling and against jamming of the throttle It is important to adjust correctly as too much feed may overload the system whereas too little feed may cause problems with faulty signals from the stop system Remember to check the filling currently especially at change of feed If stone drops are installed please remember to remove the sorted out foreign bodies preventing the outlet from blocking Fig 48 Adjustment of hopper Please note that the silo shutter must be in closed position when feed is filled into an empty silo in order to prevent the feed from piling up in the hopper 981 000 692 Part 2 5 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby n Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L
20. ecessary to replace the oil but check that the gear does not leak oil The nylon wheel driving the vibrator plate must be checked and adjusted to provide sufficient movement 9 8 Maintenance on corners The corners are mounted with lifetime lubricated ball bearings so that they need no re lubrication Normally maintenance of the corners is not necessary but checks whether the corners make noise during operation if so the cover must be dismantled and it must be checked whether something is stuck or the corner is turned incorrectly Generally it is recommended to clean the corners at least at every 1000 operation hours It is also recommended in this connection to keep an eye on the wear of the wheels as there is a risk of wearing out the corner housings if the wheels are not replaced in time The wear is biggest on the last corners before the drive unit meaning that this spot needs a special attention 9 9 After adjustment of Feeding wire tension When the system has been running for some time it is necessary to adjust the wire tension again because the wire ends at the release rollers have stretched Usually it can be seen that a row is not closing as much as other Here only the row of turnbuckles in question is adjusted 44 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 10 Technical specifications 10 1 Noise When the feeding system is runnin
21. ed and a new ORIGINAL breaking part is mounted Not original or self made breaking parts can under no circumstances be mounted as such would not protect the system in the correct way against overload Remember that the arm on the hub has to pull at the breaking part 981 000 692 Part 2 15 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 6 12Locating foreign body in the system If a foreign body is in the system it is mostly sitting in the hopper or at one of the first corners NB Note that the inspection windows of the hopper cannot be opened without disconnecting the main switch of the system If it is difficult to locate the foreign body the drive unit can be turned manually after dismantling the breaking part so that the system is tightened Once the system is tight it is blocked so that it is tight on the pull side Then the tension wheel is screwed all the way forward and the system may be taken off the tension wheel so that the system is perfectly slack on the exit side Now the foreign body can be located by checking at various spots in the system whether the system is slack or tight Removing the lids from the corners makes access to the wire 6 13 Opening for medicine If medicine should be added to the feed it is possible to take out a plug at the top of the volume dispenser so that medicine can be added into the feed in order that it is mixed during feeding I
22. ets too small to obtain safe feeding at least a 60 inclination see Fig 62 Fig 62 Installation of hose for down pipe 22 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 7 3 Operation The cellular dispenser is as standard meant for proportioning to two eating stalls If only one side shall be used either because of an uneven number of eating stalls in a pen or because a pig has to be removed from the pen push the closing throttle for the cellular dispenser to one side Fig 68 where it is automatically kept in place by the small spring locks REMEMBER to set the dispenser on half feed quantity in relation to the rest If a dispenser shall not be used close the throttle on the volume dispenser Fig 63 meaning no feed in the dispenser Fig 63 Throttle for cellular dispenser 981 000 692 Part 2 23 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 7 4 Trouble shooting Found fault cause and remedy Cellular wheel does not proportion or only to one side Closing throttle is entirely or partly closed Set throttle in correct position Cellular wheel is blocked Dismount cellular wheel and clean The feed sticks to the volume dispenser Clean the volume dispenser Rubber flaps in cellular dispenser defective Replace A few or more
23. feed pipes under the pipe hangers instead of on top Fig 65 However there will still be systems where this is impossible a o certain pipe feeding automats Here you can use a U clamp No 137000020 on top of the armature of the feeder Fig 66 A clamp is installed and fixed on each side of the feed outlet in order to prevent the feed outlet from moving during change of component Remember to tack on label before installing the clamp Fig 64 Installation of phase feeding throttle distance from corner and pipe hangers 981 000 692 Part 2 25 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 KI r L LD Fig 65 Installation of phase feeding throttle feed pipe below pipe hangers Fig 66 Installation of phase feeding throttle U clamp and feeder armature Because of emptying of the feed line the holes for feed outlets should be drilled min 238 in order to ensure an efficient outlet as theoretically almost all outlets can be the last outlets for the individual mixture At a long pipeline no problems should occur at the first outlets 8 3 Change of feed The system for change between the various feed mixtures must be designed as a round pull drive controlled by a component exchanger Fig 67 The component exchanger is mounted either on the wall or on a feed pipe so that the drive on the system is equal in pr
24. g 52 Disconnecting from releaser system 6 9 Safety system of the Transpork drive unit The drive unit is always equipped with at least two safety systems A breaking part is mounted between the disc arm of the gear shaft and the nave of the wheel The breaking part is dimensioned in such a way that the system is not damaged if e g a foreign body is getting into the system The breaking part also protects the system if the system is otherwise overloaded e g at too much filling The other safety system of the drive unit is placed on the yellow indicator Fig 53 At one end of the indicator are placed two pins moving together with the tension wheel Between the two pins is placed an end stop switch Fig 53 which switches off the drive unit if the system is too slack or too tight If the system is long the tension unit will slide much at start of the system Thus it might be necessary to increase the distance between the indicator pins by adjusting one pin in the oblong track 14 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 es KI r L LD Fig 53 Safety system at indicator If a motor driven filling of the system is used it is recommended to mount a revolution guard in the drive unit This revolution guard is delivered with fittings for being mounted to the nave bolt of the tension wheel The revolution guard detects on the screws next to the path of the w
25. g 80 Fig 80 Installation of connection pipe of the regulation pipe For further information in connection with installation of flex augers please see manual for flex augers 8 10Connection from flex auger to Transpork Feed inlets from flexible augers to feed systems can deliver into inlet from horizontal auger or from 45 inclination Here a 30 150 bend must be used as the feed will otherwise accumulate in the inlet Fig 81 136150508 136150508 Fig 81 Accessories for feed inlet from flex augers Do not forget inspection pipe after last inlet 981 000 692 Part 2 39 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 KI r L LD At phase feeding the silo A must always be first on the filling side If not problems might occur with over filled pipe Fig 82 Fig 82 Draft over placing of silo 8 11 Operation and trouble shooting For further information regarding operation and fault finding in connection with phase feeding please see our manual for phase feeding control 40 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 9 Maintenance 9 1 Shortening of feeding wire When the system is put into operation the feeding wire wi
26. g the piping contains feed which reduces the noise which makes the noise level below 70 dB Furthermore the system is designed to function in housing where the feeding system s contribution to the total airborne notice is minimum 10 2 Motors For data regarding motors we refer to data sheets of each component as well at the name plates of each motor 981 000 692 Part 2 45 SKISLUD Declaration of Incorporation of partly completed machinery Acc To the Machinery Directive 2006 42 EC annex II B Manufacturer Company Name SKIOLD A S Adress Kjeldgaardsvej 3 Post Code City DK 9300 S by Country Danmark Tel 45 9989 8887 Hereby declare that the partly completed machine meant only to be used in connection with SKIOLD TransPork MiniPork MultiChain LineFeed and MiniFeed dry feeding systems Drive Unit item numbers 131050875 131050811 131063075 131063011 131110000 181038002 181050800 181050802 141050800 141038000 121038000 121038001 121050800 121050801 121063501 121063511 Hopper item numbers 132000001 132000010 122038000 122038002 122038030 122038032 122050088 122050089 122050800 122050801 122050802 122050803 122050830 122050832 122063500 122063502 122063530 122063532 132310508 132310600 132310635 132311635 152000100 Is in conformity with and is designed and manufactured according to the following national and harmonized standards e COUNCIL DIRECTIVE of May 17th 2006 2006 42 EC
27. heel so that the number of revolution is constantly checked The revolution guard switches off the entire system if e g a foreign body gets into the system and the breaking part bursts so that you avoid that the filling continues after blocking of the system NOTE Cannot be used for TPO and MultiPork controls 6 10MiniPork Drive Unit The drive unit is always equipped with two safety systems A breaking part is mounted between the disc arm of the gear shaft and the nave of the wheel pos 3 fig 53A The breaking part is dimensioned in such a way that the system is not damaged if e g a foreign body is getting into the system The breaking part also protects the system if the system is otherwise overloaded e g at too much filling The other safety system of the drive unit is placed on the threaded rod A sleeve pos 1 fig 53A is screwed onto the threaded rod and this sleeve must always be positioned opposite to the micro switch pos 2 fig 53A If the spring tension is too low or indeed too high the sleeve will move away from the switch and cause the system to stop Fig 53a MiniPork safety system 6 11 Replacement of breaking part A breaking part is mounted between the driving wheel and the gear shaft The breaking part will protect the system against overload if e g a foreign body gets into the system If the breaking part bursts the faults must be located and repaired before the two plate pieces are dismantl
28. intenance S n WHH E HHHHHHE HEHE H H H H H H HHHEEEMMNMNMNMMMn 41 9 1 SHORTENING OF FEEDING WIRE 0 0000100000 1 41 9 2 INSPECTION OF WIRE TENSION ccccccsececcccescececcscececnsccececceseececceseeceecseseeenssescecneneeseenenees 42 9 3 INSPECTION OF nennen etes eene KA KA EKA KA KA KA KA AKA KA HA KA KA 42 9 4 MAINTENANCE OF DRIVING 00 1 etse keke E KA KA KA KA KAKA KA KA KA A AA KA KA KA kk KHK KA kK kk 42 9 5 TURNING THE DRIVING WHEE L cccseecccccscececcsccececnscececnsseececcseececceseesecnesesecensneesecaeners 43 9 6 TURNING OF THE DISCS ON THE DRIVING 0 0000 43 9 7 MAINTENANCE ON HOPPER ccccccccccccscessscececccccecsessscccecesccessususseeseccesseseussucececseseseuensaseeees 43 9 8 MAINTENANCE ON CORNERS 44 9 0 AFTER ADJUSTMENT OF FEEDING WIRE 44 10 Technical specifications E i i EEE kk kk kk kk kK kK KK KK KK KK KK 45 LOST NORE 45 10 27 IWIOTOR S 45 4 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby n Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 6 Instruction Manual 6 1 Start stop of system Ther
29. iscs at the shaft end pos 1 and 2 Fig 84 Then the driving wheel can be removed and the bush at the wheel nave can be moved to the other side pos 3 Fig 84 The wheel can now be re mounted Do remember to lubricate the shaft with a little cupper grease Fig 84 Driving wheel can be turned 9 6 Turning of the discs on the driving wheel In time the discs on the driving wheel may be worn out They can be turned around one time so a new wearing surface is available The screws pos 1 Fig 85 holding the discs are loosened and then each disc pos 2 Fig 85 is turned a half round and the screws are tightened again Fig 85 The discs can be turned 9 7 Maintenance on hopper The hopper is designed in such a way that the feed does not tend to accumulate in the hopper housing Yet it is recommended to clean the hopper at least at every 1000 operation hours in order to avoid that old feed becomes tainted The frequency of this cleaning depends very much on the feed type If e g much fat is used in the feed it may be reasonable to clean more often 981 000 692 Part 2 43 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD If a stone trap wheel is mounted on the hopper it must be cleaned frequently and at least at every 500 working hours in order to function satisfactorily The gear on a motor driven hopper if any is filled with oil at delivery and it is not n
30. ith replacement of the feeding wire the driving wheel must always be replaced or turned if that has not been done previously At driving wheels with loose discs it is recommended to turn or replace the discs on the driving wheel because worn discs may have a unfavourable influence on the lifetime of a new feeding wire see section regarding turning of discs later in this manual It is very important to get a new wear surface on the drive unit in order to achieve the correct pitch and engagement on the wheel 9 4 Maintenance of driving unit The drive unit demands very little maintenance but it is of course relevant to take off the front system and check a few things regularly and at least at every 500 operation hours Remember to disconnect the safety switch while the front plate is dismantled Check that the tension bracket slides easily on the two shafts Lubricate with a little oil if necessary Check the cabinet for possible dust and feed for preventing tainting Check the driving wheel for wear Turn or replace if it is worn The gear on the drive unit is lubricated at delivery and it is not necessary to replace the oil Check that the gear does not leak oil 42 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 9 5 Turning the driving wheel The driving wheel on the drive unit can easily be turned by dismantling the breaking part and the d
31. ll stretch The stretch is biggest at the beginning where it is necessary to keep an extra eye on the wire tension The drive unit is also equipped with a stop switch switching off the system if the wire gets too slack When the feeding wire has stretched so much that a shortening is necessary normally several discs can be shortened off The front plate is dismantled and the joint link is driven forward in the drive unit After that do remember to disconnect the current at the safety switch so that the system does not suddenly start After the tension wheel is driven forward towards the driving wheel dismount the joint link in both wire ends It is recommended to shorten a disc after and before a joint in turns see Fig 83 as it usually is around a joint a later break will occur The screws at the wire ends that have to be shortened are unscrewed and pulled out of the joint A solid jerk is made at the first disc in order to prevent eventual tensions in the wire One disc is removed Use the assembly template to cut at the correct position see section 5 12 1 After shortening the wire and before lubricating the wire ends and mounting it in the joint link check that the heart yarn has not withdrawn in order to ensure that they are mounted into the joint link See also section 5 12 1 where assembly of feeding wire is further described Remember to lubricate the wire ends with system oil before remounting the joint link Fig 83 Sh
32. n the assembly sleeve for drive shaft is pushed into position and the 981 000 692 Part 2 21 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 es KI r L LD protection pipe is closed with the assembly sleeves Do not forget to mount the screw on the joint for drive shaft If not it might be displaced during feeding resulting in no connection Fig 60 IN Fig 60 Screw for assembly sleeve At termination of gear drive use a bushing at both ends of the shaft The shaft itself must be positioned in the bushing Fig 61 in order to reduce the wear on the cellular dispenser as much as possible Fix the end bushing to a machine or a wall N Fig 61 Bushing for shaft end 7 2 3 Installation of down pipe Install the various down pipes 50 8 mm in the individual feeding stall They can profitably be cut in an angle of 45 at the bottom in order to reduce the risk of piling up Install the down pipes either with double U iron in the front of the eating stall or with wall armature on wall equipment Once the down pipe is installed connect it to the cellular dispenser by means of the supplied plastic hose that ought to be mounted on the cellular dispenser first It might be necessary to lubricate the hose with oil before installation for enabling this The hose must be as short as possible in order to avoid that the inclination g
33. on and reset Safety switch not connected after disconnection Connect and re start Fuse blown Find reason and re start after replacement of fuse Fault on revolution guard in drive unit Reset and re start once the reason is found No feed in the system Silo empty Fill the silo or go to alternative silo Hopper blocked or incorrectly adjusted Clean and adjust Check function of motor driven hopper if any 981 000 692 Part 2 17 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L 7 feeding 7 1 Field of application Transpork trickle feeding is designed for new installation of Transpork feeding systems with volume dispensers or for later installation on existing volume dispensers with an outlet designed for g 75 mm pipes The system is primarily used for feeding of untethered sows gilts and porkers in flock in order to ensure that all animals get the required feed quantity However the system can be used in other pig sections where a restrictive feeding in animal flocks is required The system is meant for feeding of meal and pellet with a max diameter of 5mm anda max length of 10 mm One proportioning unit is meant for feeding of one or two animals A proportioning unit consists of a volume dispenser 1 a cellular dispenser 2 two flex hoses for connection to cellular dispensers and down pipes 3 two down pipes 250 8mm 4 and two a
34. oportion to the feed throttles The feed pipes must be supported so that they do not move when the component exchanger is working The component exchanger is coupled directly to the feed computer from where it can also be operated manually 26 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby a Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI L LD The number of feeding spots per component exchanger depends on the design of the system drive The component exchanger has a tractive effort of 2000 N which is sufficient for closing 40 feed outlets At bigger systems more component exchangers are mounted IUD _ _ 1 MET fi Fig 67 Draft of housing layout 8 4 Adjustment for component exchanger During start up it might be necessary to re adjust the switches for pos A and pos C on the component exchanger Fig 68 Usually it appears by the feeding computer not getting a feedback that it has changed At adjustment the switches are moved 1 mm at a time At missing feedback from C they are moved towards the motor and at missing feedback from A they are moved at the opposite direction This procedure should only take place d
35. ortening of feeding wire The wire is placed in the drive wheel and the open corner wheel is remounted The lid of the drive unit is installed and the spring on en eventual telescopic joint is tightened Check that the indicator is the green field 981 000 692 Part 2 41 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 9 2 Inspection of wire tension It is recommended constantly to keep an eye on the joint link in order to avoid a demolition of the feeding wire Re tighten the pivot screws after 50 100 hours of operation and at the same time check the distance around the joint link After many operation hours it must be expected that fatigue failure start on the wire around the joint link This means that every now and then and at least after 500 hours of operation the joint link should be driven forward in the drive unit in order to check the joint At a starting wire break at the joint the system must be shortened as described above Thereby it can be avoided that the feeding wire starts to flush and to be destroyed at a long piece 9 3 Inspection of Feeding wire It is recommended to keep an eye on the condition of the feeding wire and to check it at least at every 1 000 operation hours If the wire shows signs of wear e g by bulges between the discs it must be replaced at once If the wire often breaks it is time for a replacement Do remember that in connection w
36. r The motor is blocked The multi fuse is activated 2 The electric valve turns with great difficulty and slowly The power supply is too low The axial tension on the valve is too high Feed has accumulated Conveyor pipes are not horizontal 34 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI Car L 8 8 5 Guidance for mounting the valve Please note e Never assemble the electric valve against or on a wall e Always assemble the electric valve on a horizontal part of the conveyor pipes Use if necessary a flexible pipe between the valve and the outlet pipe so that the outlet pipe can be mounted at an angle e The pipe has to enter and leave the valve in a straight line It is important that the axial pressure on the valve is as low as possible e Make sure that the conveyor pipes and the valves are hung correctly this means that they have to hang completely free and in a straight line Fig 75 Fig 75 Mounting of Feedvalves e Use as much as possible 1 pipe with T Clamps 1 x tube diameter for supporting the pipes Where this is not possible a chain can be used hanging from the ceiling If two or more valves are hung close to one another a support or chain has to be placed between the valves Fig 76 981 000 692 Part 2 35 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 7
37. regarding mutual convergence of the membership states machinery legislation 89 392 with all later changes with special reference to appendix 1 regarding significant safety and health requirements in connection with design and manufacture of machinery The Machinery Directive o DS EN ISO 12100 1 2003 Machine Safety Basic terms and overall principles for planning designing and shaping Part 1 Basic terms and methods o DS EN ISO 12100 2 2003 Machine Safety Basic terms and overall principles for planning designing and shaping Part 2 Technical principles o DS EN 294 1994 Machine Safety Areas of danger and safety distances Hand and arm protection e COUNCIL DIRECTIVE of December 15 2004 regarding mutual convergence of the legislation on electromagnetic compatibility 2004 108 EC EMC Directive o DS EN 61000 6 3 2007 Electromagnetic compatibility Generic emission standard Part 1 Private homes businesses and light industry o DS EN 61000 6 1 2007 Electromagnetic compatibility Generic standard of immunity Part 1 Private homes businesses and light industry e COUNCIL DIRECTIVE of December 1211 2006 regarding mutual convergence of the legislation on electric devices meant for use within certain voltage spans 2006 95EC Low Voltage Directive o EN60204 1 2006 Machine Safety Electric devices on machines Part 1 General Requirements This partly completed machinery must NOT be put into service before the complete
38. residue silo Intermediary inlets are difficult to control from a capacity point of view and may cause overloading of the auger if following lines of direction are not followed carefully There may only be mounted one intermediary inlet on an auger The distance from the first inlet to the intermediary inlet may not exceed 3 m The total length of the auger may not exceed 20 m when an intermediary inlet is mounted The first inlet and the intermediary inlet shall be mounted in line so that the auger is totally straight to and including the intermediary inlet If the intermediary inlet is mounted under a bigger silo from where pellets are proportioned the cover pos 1 Fig 78 shall be mounted in order to reduce the pressure on the auger A pipe for inlet regulation shall be mounted in the intermediary inlet This pipe shall at the same time prevent that the auger gets up into the inlet The pipe shall be connected to the regulation pipe of the first inlet as follows Fig 79 E md Fig 79 Installation of regulation pipe 38 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD The length of the connection pipe shall be similar to the centre distance between the inlets The connection pipe is led 85 mm into the regulation pipes and fastened with perforation of 8 mm steel bolt and lock nut Fi
39. sers are closed and the end stop 981 000 692 Part 2 11 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 es ICI r L LD switch pos 6 Fig 47 must be activated when they are open If the release does not reach the correct position within 2 minutes e g because of a blocked system transmission the controller stops the feeding and gives alarm If the controller gives alarm the error is corrected and the controller is reset and re started and then the controller continues the feeding sequence from where it was stopped The automatic release model 2 000 N can normally operate up to 100 volume dispensers mounted in the release system with return drive If you need to release more volume dispensers more releases are parallel coupled The control box contains an overload protection for protecting the actuator against overload It might be necessary to adjust the potentiometer in the overload protection if the actuator does not give satisfactory power The adjustment is done when the release is in outlet position by screwing up the potentiometer until the actuator starts to buzz and then the potentiometer is turned a little backwards until the overload protection is re coupled and the actuator stops to buzz 6 6 5 Automatic Release Model 2007 and after In systems with automatic release a feed sequence starts with filled volume dispensers being emptied into the through of the anim
40. ssembly sleeves 5 The various proportioning units are connected by means of a driving shaft 6 protected by a pipe Apart from that at least one gear motor 7 should be used as a minimum at every 20 cellular dispensers see Fig 55 Fig 55 Construction of trickle feeding 18 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 KI r L LD The volume dispensers are filled by a dry feeding system During feeding the gear motors operate with a pulse pause time that can be regulated depending on the quantity of feed to be fed per minute The system can feed from 0 05 to 2 8 litres per eating spot per minute The cellular dispenser will proportion feed to one or two animals in an even speed which keeps the animal at the eating spot until all feed is fed thus avoiding fights during feeding The feeding time can be adjusted to the time it takes to feed the animals that shall have the most feed Trickle feeding is controlled from a controller in which can be adjusted the necessary feeding speed by means of a timer system where you adjus
41. stallation of cellular dispensers Install the cellular dispenser in the outlet hopper by pushing it up into the hopper and fastening it by screw pos 7 Fig 56 7 Fig 56 Installation of cellular dispenser Now connect the various cellular dispensers to the gear motor drive by means of the drive shaft which is drawn through X number of cellular dispensers depending on the distance between them One end is led to the spot where the gear motor is to be mounted Then adjust the gear motor in height and length During mounting of shaft for cellular dispensers the protection pipe g50 8mm and the sleeves between the various dispensers must be shortened and mounted An easier mounting is achieved by pointing the square shaft a little The mounting should start from the gear motor and to the sides In order to facilitate a possible service it is important that the distance on the protection pipe is equal to the distance between the two dispensers minus 100 mm This distance will be covered by assembly sleeves and will at the same time permit the opening to the joints of the drive shafts The opening on the assembly sleeves must point downwards so that possible dust and moisture can get out Fig 57 Fig 57 Shortening of protection pipe 20 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby n Tel 45 99 89 88 87
42. t is marked on Fig 54 where the plug can be taken out Afterwards a plastic plug that can be ordered from your TransPork dealer can close the hole Fig 54 Opening for medicine 6 14Cleaning Inside inspection of the volume dispenser The easiest way to clean the volume dispenser is to wash with water possibly cautiously with a high pressure cleaner where it is recommended to turn down the water pressure to avoid damage to the volume dispenser 16 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby n Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 6 15Trouble shooting Breaking part is burst Foreign body in the system see the section Locating Foreign Body in the System Too heavy filling Adjust the hopper Joint link mounted incorrectly Check by means of assembly template Critical dimension of granulates which stick between pipe and discs The granulate diameter cannot exceed 5 mm and the length must be under 10 mm The system is not recommended for beet pellets and other hard pellets Corner makes noise Corner housing mounted so that it has become jammed Adjust Foreign body in the corner wheel Clean the corner Worn out corner wheels Replace the wheels Corner wheel mounted with wrong revolution direction Turn the wheel The system does not start Wrong system tension so that switch in drive unit disconnects Adjust system tension Motor protection cuts off Find reas
43. t the pulse and pause time necessary for achieving the required feeding speed and the necessary feeding time in order to be able to empty all volume dispensers The basic unit comprises a controller with timers and two motor guards for the gear motor Apart from that you can connect a random number of extra boxes for motor guards each with the possibility of up to 6 gear motors Use a gear motor at every 20 cellular dispensers The system can be started manually or with start from a 24 hour clock It is possible to start the filling systems after finished feeding There can also be connected a magnet valve for water so that the animals can get water in the manger during feeding 7 2 Installation of trickle feeding special parts 7 2 1 Installation of gear motor drive If possible the gear motor must be placed in the middle of the number of cellular dispensers for which the drive is meant The single gear motor is meant for up to 20 cellular dispensers The gear motor ought to be mounted on a wall with a wall garniture or on a cleaning wall pen partition with wall garniture mounting iron It is important that the gear motor is mounted in a solid way However the final placing cannot be made until the drive shaft is mounted Mount shaft connector and pipe sleeve on the gear motor drive shaft 981 000 692 Part 2 19 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 7 2 2 In
44. uring start up of the system If the control switches are not activated within the programmed time the controller gives alarm The error must be remedied before the system is re started 981 000 692 Part 2 27 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI Car L Offnungsrichtung Opening direction Sens d ouverture Abningsretning ei Fig 68 Component exchanger Fig 69 Shows the connection diagram for Control switches Lodd kytt rympetlex Fig 69 Circuit diagram for control switches 28 981 000 692 Part 2 SKIOLD A S Kjeldgaardsvej 3 DK 9300 Saeby Tel 45 99 89 88 87 Fax 45 99 89 88 77 S KI r L LD 8 5 Round pull drive When mounting the round pull drive it must be noted that the phase feeding throttle must move to the left seen from the side with the wing nuts when the system changes from neutral mixture A to mixture B or C because of label for adjustment of throttle The piano wire should be mounted so that it is on the opposite side of the phase feeding throttle in proportion to the wing nut see Fig 70 At the volume dispensers the piano wire for the phase feeding throttle must be placed at the opposite side of the release arm in or
Download Pdf Manuals