Home
A9GT-QBUSS type Bus connection User`s Manual
Contents
1. MITSUBISHI A9GT QBUSS type Bus connection User s Manual Thank you for purchasing the MELSEC GOT Series To ensure correct use of this equipment please carefully read this manual prior to use A9GT QBUSS U Type 1DM132 IB NA 0800073 D 0512 MEE Mitsubishi Graphic Operation Terminal Manuals The following manuals are relevant to this product Refer to the following list and order the required manuals Detailed Manual Manual Name Manual Number Type Code A985GOT A975GOT A970GOT A960G OT User s Manual Available as option H 4005 1DM099 Relvant Manual For relevant manuals refer to the PDF manual stored within the drawing software 1999 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Read these precautions prior to use When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in this manual Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the CPU module user s manual for a description of the PLC system safety precautions These SAFETY PRECAUTIONS classify the safety precautions into two categories DANGER and CAUTION DANGER Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly i AACAUTION Procedures which may lead to a dangerous condition and cause superficial to m
2. Specifications subject to change without notice Printed in Japan on recycled paper
3. reverse the removing procedure Here securely install the slot cover and securely tighten the mounting screws 2 pcs within the specified torque range 36 to 48N cm 3 2 to 4 2 b inch When A9GT QBUSS is used the mounting fixture of the GOT interferes with the connector due to the shape of the communication cable connector Please substitute for the mounting fixture included in this product and use the mounting fixture as shown in diagram below Back side of GOT main unit it nun A9GT QBUSS 00 00000 0 00000 OU OUOUU Communication cable connector Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict
4. 1 252 2 consumed GOT 5VDC Included in GOT Weight kg Ib 0 09 0 2 1 The power supply of PLC CPU is the current consumed while turned on when the power supply of GOT is turned off The power supply is supplied from the GOT side and PLC CPU side 2 The power supply of GOT is the current consumed while turned on when the power supply of PLC CPU is turned off The power supply is supplied from the PLC CPU side 3 NAME OF THE PARTS AND OUTLINE DIMENSION DRAWING 145 6 5 73 Lo 5 LSI p oeo 73 7 2 9 P Ec ay wo 0 68 gt 17 3 unit mm inch connecting Interface connection cable IN side mounting screw hole 48N cm included with this product mounting screw hole 48N cm included with this product 5 Ratingplate 4 INSTALLATION PROCEDURE 1 Loosen the mounting screws 2 pcs which secure the slot cover Remove the slot cover Save the removed slot cover Insert the pretruding portion of the A9GT QBUSS into the recessed portion of the GOT Securely press the communication board against the GOT 3 Tighten and fix the mounting screws 2 pcs of the A9GT QBUSS within the specified torque range 36 to 48N cm 3 2 to 4 2 lb inch 4 To remove the A9GT QBUSS reverse the installing procedure To install the slot cover also
5. edium injury or physical damage only if not carried out i properly Depending on circumstances procedures indicated by Z CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user DESIGN PRECAUTIONS ZA CAUTION Do not bundle control lines or communication wires together with main circuit or power lines or lay them close to these lines As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS gt DANGER Before mounting or dismounting this module to or from the GOT always shut off GOT power externally in all phases Not doing so can cause a module failure or malfunction Before connecting the Bus connection cable to this module always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction ZA CAUTION Use this module in the environment given in the general specifications of the GOT User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure o
6. quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system SS I Country Region Sales office Tel Country Region Sales office Tel USA Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500 Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 2100 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation Rua Correia Dias 184 Instrumentation Plaza 103 Cao Bao Rd Edificio Paraiso Trade Center 8 andar Shanghai 200233 China Paraiso Sao Paulo SP Brazil Tel 86 21 6120 0808 Tel 55 11 5908 8331 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg UK Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 Alexandra Road 05 01 02 Italy Mitsubishi Electric Europe B V Italian Mitsubishi Electric Building Branch Singapo
7. r malfunction Overtightening can cause a drop failure or malfunction due to GOT or screw damage WIRING PRECAUTIONS CAUTION Insert and fit the bus connection cable into the connector of the module to be connected until it clicks After fitting check for looseness Not doing so can cause a malfunction due to a connection fault STARTUP AND MAINTENANCE PRECAUTIONS gt DANGER Do not change the switch setting during to the be in operation Doing so can cause a malfunction Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a module failure or malfunction ZA CAUTION Do not disassemble or modify any module This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this module directly Doing so can cause a module malfunction or failure Always secure the cables connected to the module e g run them in conduits or clamp them Not doing so can cause module or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the module Doing so can cause module or cable damage or a malfunction due to a cable contact fault Before handling the unit touch grounded metal or similar object to dischange the static electricity from the human body Failure to do so may cause the
8. re 159943 Centro Dir Colleoni Pal Perseo Ingr 2 Salaki o a aR Via Paracelso 12 20041 Agrate B pan A Tech Co Ltd Milano Italy 898 28 29 30 S V City Building Office Tel 39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road Spain Mitsubishi Electric Europe B V Spanish Bangkpongpang Yannawa Branch Bangkok 10120 Carretera de Rubi 76 80 Tel 66 2 682 6522 08190 Sant Cugat del Valles Indonesia P T Autoteknindo SUMBER MAKMUR Barcelona Spain Jl Muara Karang Selatan Block a Utara Tel 34 93 565 3131 No 1 Kav No 11 Kawasan Industri France Mitsubishi Electric Europe B V French Pergudangan Jakarta Utara 14440 Branch Tel 62 21 663 0833 India Messung Systems Put Ltd 25 Boulevard des Bouvels E2210 Electronic Sadan NO 111 Unit No15 Nanterre Cedex France M LD C BHOSARI PUNE 411026 India TEL 33 1 5568 5568 Tel 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission
9. unit to fail or malfunction DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste 1 OVERVIEW This User s Manual describes the A9GT QBUSS type Bus connection communication board hereinafter A9GT QBUSS The A9GT QBUSS is mounted on the A985GOT V A975GOT A970GOT A960GOT hereinafter GOT to PLC system of the Q Series via a bus The A9GT QBUSS is used with the following system 1 One GOT is connected to one PLC CPU or 2 Used with the last GOT when two or more GOTs are connected to one PLC CPU Since this module has one interface GOT back eS A9GT QCNB type Bus extension connector box Necessary when the distance between GOT and the base unit exceed 13 2m it is When A9GT QBUS2S is used it is necessary to set the increased number of stages and the I O slot number Setting is made in the Setup of the utility feature of GOT Refer to the GOT A900 Series User s Manual Connection System Manual for the configuration of the bus connection system and setting When using A9GT QBUSS version A or higher or the SW3D5C GOTRE PACK is required A9GT QBUSS can be used only with QCPU Q mode After opening the box check that the following items are present Description Quantity A9GT QBUSS Communication M3x10 o O 1 S O board GOT mounting fixture 2 SPECIFICATION n 16 points I O assignment l Ooccupied points intelligent 16 points Internal CPU 5VDC 39
Download Pdf Manuals
Related Search
Related Contents
MANUAL DEL USUARIO Manual de instalación y uso Videograbador de 4 cámaras さか2014年7月 1 HistaSure ™ Fish Trust Leather Protective Sleeve Perfect BW importantes instruções de segurança! Zセンサ Bulletin d`informations : printemps 2006 Guide d`apprentissage sur Rhone-Alpes Copyright © All rights reserved.
Failed to retrieve file