1. LCD screen displays the results of all four quarters On Off Switch a handle housing a 9V battery On Off Button a handle with a 9V battery The device housing is drop proof what makes its use more safe and cleaning easier The instrument is made of polypropylene resistant to atmospheric conditions most chemicals shock breakage and not easily wet by milk It is sealed and waterproof for easy washing and cleaning OPERATION 1 Model 4x4Q MAST The display indicates the proper work of the device The first check out of the detector should be conducted with no milk in the cup in the empty when electrodes are spaced After pressing the button four column of dashes are displayed indicating the device readiness to work NOTE The device switches off after 30 seconds of idle operation for battery saving purposes After pouring milk into all four cups press the on button the device will count down 3 seconds 3 3 2 2 1 1 3 3 2 2 1 1 And the screen displays the results of all four quarters for example 370 380 380 380 Additionally the display indicates the exhaust state of the battery A flashing battery symbol signals that the battery is to be replaced 10 units is the lowest result possible whereas the measurement range is 10 990 units After the level of 990 units has been exceeded dashes are shown on
2. MEASUREMENTS Before starting your measurement the following should be done 1 Check the work of the detector in the open air ensuring that the battery is fully charged 2 Ensure that the electrodes in the cups are clean Contamination of electrodes with skin oil from handling or examination while on display in stores and or dried milk fat can result in incorrect high readings If required wipe the electrodes with methylated spirits clean cloth or tissue or similarly with kitchen detergent and rinse off a prepare a solution pour a pinch of salt into a glass of water of room temperature dissolving it completely b fill out the cups with the solution and read the result it depends on the solution concentration c Pour out the solution into the glass and clean thoroughly the electrodes with a tampon moisten with the liquid for washing the dishes Rinse the cups under the tap shaking the water remaining off d pour the solution into the cups again and read the result If there is a remarkable drop in the result in comparison to the previous measurement it means the electrodes were coated with fat the best is to repeat cleaning procedures until it is sure that the results do not change any more The latter means the electrodes are now clean Note that even touching the electrode with a finger may contaminate the electrodes 3 Prepare a bucket full of warm water for rinsing the cup after each measurement Add
3. cups should be immersed in water and vigorously moved to remove any residues of milk 7 Another cow may be tested immediately after rinsing the measuring cups and a short press of the switch All the results will be erased and readiness for another test will be displayed 11 8 The detector is automatically switched off after 30 seconds of idle operation following the last pressing of the switch The device may be also switched off by pressing and holding the switch for more than 3 seconds Model 4Q MAST 1 Switch the device on place the measuring cup under teat A and squirt the first stream of milk into the measuring cup to fill it up minimum volume is approx 1 cm from the top edge 2 Wait for a second and press the on off switch a result will be displayed For example 370 3 Discard the milk to the last drop and press the switch again dashes will flash in the next column of the display 4 Repeat the same procedure for teats B C and D to obtain readouts for the four quarters for example 370 380 320 380 5 For easier detection of the quarter in danger of the disease it is possible to press the switch again to display the differences between the individual quarters in relation to the highest result obtained for example 10 0 60 0 After reading the results and differences for the individual quarters they should be interpreted according to the principles presente
4. in practice it is never reached 3 Model 1Q MAST The display indicates the proper work of the device The first checkout of the detector should be conducted with no milk in the cup in the empty when electrodes are spaced After pressing the button two dashes are displayed indicating the device readiness to work After the switch is pressed again the display shows the value 1 0 Number 1 stands for no contact of the electrodes and number 0 indicates that no measurement has been made except for automatic verification of operation 1 0 When the device displays two dashes readiness for measurement the cup should be filled with milk and the switch should be pressed to read the result 350 Additionally the display indicates a low battery level A flashing LO BAT symbol indicates that it is necessary to replace the battery LO BAT Technical data indicate that the lowest result is 10 units and the measurement range is between 10 and 1990 units Beyond those limiting values the display shows 1 0 the same as for a dry trial measurement The measurement range of the device significantly exceeds the maximum resistance of the milk tested Therefore in practice it is never reached NOTE The MASTITIS DETECTOR all models is not intended for the measurement of pooled milk The device should be used only for measuring milk collected directly from udders
5. the display the same symbol as in the case when the device tried in the empty air 2 Model 4Q MAST The display indicates the proper work of the device The first checkout of the detector should be conducted with no milk in the cup in the empty air when electrodes are spaced After pressing the button four column of dashes are displayed indicating the device readiness to work Now the consecutive milk quarters can be measured Blinking dashes indicate the column where the results from specific milk quarter will be shown To take a measurement the milk is to be poured in and the switch pressed Note The device switches off after 30 seconds of idle operation for battery saving purposes After the switch is pressed the flashing dashes disappear and result will come up in specific numbers Next the flashing dashes will appear in the next column Similarly all other measurements from the next quarters will be done 370 Additionally the display indicates a low battery level When the battery icon flashes it indicates that it is necessary to replace it Technical data indicate that the lowest result is 10 units and the measurement range is between 10 and 990 units Beyond those limiting values the display shows dashes the same symbol as for a dry measurement The measurement range of the device significantly exceeds the maximum resistance of the milk tested Therefore
6. CONTENTS TSINFRODUGTION a a 3 2 GONSTRUGTION 4 SL 7 4 MEASUREMENT Sissy 10 5 INTERPRETATION OF RESULT Sissit ennaa anal 14 6 BATTERY REPLAGEMENT iier kaa oi a aaas 15 Ts TECHNICAL DATA k is tine erimda aaa e aiaa 16 END NOTES Kian iaai laden 16 ELECTRONIC DETECTOR OF SUBCLINICAL MASTITIS IN COWS e Enables the rapid detection of subclinical mastitis in a large number of cows directly in the cowhouse just before milking It allows appropriate preventive steps to be made that could prevent the disease from its transition into a clinical condition e Has a mobilising effect on breeders and the personnel taking of animals e Improves the economic results of stock farming INTRODUCTION Mastitis inflammation of the udder is one of the most important and costly problems in dairy farming Subclinical states of mastitis are particularly dangerous In this state milk looks normal and the udder or quarter affected appears healthy Subclinical mastitis can rapidly become clinical mastitis or can continue at subclinical levels affecting milk production milk quality and spreading infection to other cows in the herd Research carried out over many years has established that the development of subclinical mastit
7. d in the following section 6 After a cow has been tested the device should be rinsed the cup should be immersed in water and vigorously moved to remove any residues of milk 12 Note Rinsing should also be completed after testing a quarter in which a subclinical condition has been detected That way residues of milk from that sample will not affect the measurement of another quarter fi Another cow may be tested immediately after rinsing the measuring cup and a short pressing of the switch All the results will be erased and readiness for another test will be displayed The device may be switched off by pressing and holding the switch for more than 3 seconds The detector automatically switches itself off after 30 seconds of idle operation following the last pressing of the switch Model 1Q MAST Press the on off switch to display readiness for measurement two dashes Place the measuring cup under teat A and collect the first stream of milk into the measuring cup to fill it up minimum volume is approx 1 cm from the top edge Press the switch again and read the result Repeat the same procedure for teats B C and D After a cow has been tested the device should be rinsed the cup should be immersed in water and vigorously moved to remove any residues of milk Note Rinsing should also be completed after testing a quarter in which a subclinical condition has been detected That way residues of milk from that sample
8. he handle 2 Slide the battery from the handle and disconnect it from the catch 3 Install a new battery and slide it into the handle 4 Screw both screws in to fix the cover Take care to ensure even compression of a gasket We recommend using alkaline batteries or high capacity regular batteries of renowned brands 15 TECHNICAL DATA Weight approx 450 g 4x4Q Mast approx 300g 4Q Mast 1Q Mast Power supply Ibattery 9 V type 6 F22 Power consumption approx 17 mA 4x4Q Mast approx 14 mA 4Q Mast approx 12 mA 1Q Mast Display LCD display 4 x 3 digits 4x4Q Mast 4Q Mast LCD display 3 5 digits 1Q Mast Minimum graduation 10 units Measuring range 10 to 990 units 4x4Q Mast 4Q Mast 10 to 1990 units 1Q Mast Operation and storage temperature 0 C to 50 C Equipment 1 Electronic detector battery included 2 Packaging 3 User Manual and Warranty Card END NOTES Cleaning of electrodes e Dirty greasy electrodes cause false results to be given by the device too high Also the presence of other liquids than milk on the electrodes may cause false results e g too low Therefore maintaining the cleanliness of the electrodes and the whole device is of utter importance Degreasing cleaning of electrodes should be performed before each session of measurements Commonly used detergents are used for cleaning washing up liquid washing powder In those regions where the tap
9. he udder resulted in the development of the DRAMINSKI MASTITIS DETECTOR by Mr J 1989 with the co operation of Polishagricultural universities CONSTRUCTION Currently there are three models of Mastitis detectors are available 1 Model 4x4 Q MAST The device consists of a 4 measurement vessel cups with electrodes electronic unit with LCD panel handle containing a standard 9 volt battery marked as 6F22 6LR61 or 1604E and a switch Application of a special display showing results taken from all 4 quarters makes work more effective a measuring vessel cup with two metal electrodes LCD screen displaysthe results of all four quarters On Off button a handle with a 9V battery 2 Model 4Q MAST 3 Model 1Q MAST The device consists of a one measurement vessel cup with electrodes electronic unit wath Lop panel hande containing standard 9 volt battery marked as GF22 and The device consists of a one measurement vessel cup with electrodes electronic unit switch Application of a special display showing results taken from all 4 quarters makes with LCD panel handle containing a standard 9 volt battery marked as 6 22 and work more effective switch Application of a special display showing results taken from single quarters a measuring vessel cup with two metal electrodes LCD screen displays the results of the one quarter a measuring vessel cup with two metal electrodes
10. is is accompanied by a rise in the level of salt in the milk which immediately lowers its electrical resistance Since the discovery of this relationship electronic methods of detecting subclinical mastitis have become widely accepted and practical It seems that only one cow is affected Fig 1 ee ee r 2 1 However in reality the situation is D T 8444 different Fig 2 20 100 of cows a herd DAS may be sick Undiagnosed subclinical 3 r r Yr T BB conditions are a cause of the most severe ya 4 ee yg g 105 sustained by milk producers RESAS S KH MASTITIS is a world wide problem Yr ELECTRONIC DETECTOR 8573498 0884 SUBCLINICAL MASTITIS r successfully used by farmers all over the whole world FH healthy cows P ill cows clinical mastitis ill cows subclinical mastitis symptoms are clearly visible symptoms are invisible Research carried out over many years has established that the development of subclinical mastitis is accompanied by a rise in the level of salt in the milk which immediately lowers its electrical resistance Since the discovery of this relationship electronic methods of detecting subclinical mastitis have become widely accepted and practical The relationship of milk electrical resistance and health of t
11. itionally another empty bucket will be useful for pouring out the milk from the cup after the measurement To comply with the hygienic regulations you must not pour the milk out on the cowshed bedding ALLWAYS THE FIRST SQUIRTS OF MILK SHOULD BE MEASURED that are squirted directly to the measurement cup Each quarter should be examined separately 10 Measurements are made in the following way Model 4x4Q MAST 1 Place the cups under teats A B C D and squirt the first streams of milk to fill the cups minimum volume approx 1 cm from the top edge of the cup Milk should be squirt as fast as possible 2 Then press the on off switch The device will count down three seconds 3 3 2 2 1 1 3 3 2 2 1 1 3 Results for each quarter will be displayed for example 370 380 380 380 4 For easier detection of the quarter in danger of the disease it is possible to press the switch again to display the differences between the individual quarters in relation to the highest result obtained for example 10 0 0 0 After reading the results and differences for individual quarters they should be interpreted according to the principles presented in the following section 5 Pour the milk into the prepared bucket to the last drop In the case of a milk yield hall the milk may be discarded into the catch basin 6 After a cow has been tested the device should be rinsed
12. lt below 300 but the maximum difference is only 20 units quarter C 300 quarter D 300 Important factors affecting the level of results obtained from the tests of healthy cows 1 animal s age 2 breed the above interpretation is valid for black and white hf cows Jersey cows would have readouts at a higher level individual properties of animals e g fat content in milk nutrition composition of a dose or its alteration may influence results physiological condition e g tests should be discontinued during heat period metabolic abnormalities acidosis or alkalosis may be diagnosed based on a surprising significant increase or decrease of results for all cows in a herd Note Only the systematic control of cows allows the proper and effective use of the detector The detector may not be used for the testing of quarters clearly inflamed and with significant changes in milk In those cases the correct interpretation of results is impossible The method of the measurement of changes in milk impedance may be used for the detection of the early stages of Mastitis subclinica O20 00 BATTERY REPLACEMENT If the battery icon flashes 0 for some time or permanently LO BAT symbol is displayed the battery needs to be immediately replaced Results obtained with a device indicating a low battery are not reliable and cannot be properly interpreted Battery replacement procedure 1 Unscrew both screws fixing the cover to t
13. nits a sudden drop is observed to the level of 250 300 units the cow should be considered at risk of mastitis Regarding item 2 A difference exceeding 40 50 units between the highest and the lowest result obtained for quarters in a tested cow indicates the onset of subclinical mastitis It is necessary to examine the cow systematically before each milk yield and observe it for the progression of the disease a further drop of results for the suspected quarter Moreover particular care and increased hygiene before and after milk yield are necessary SAMPLE INTERPRETATIONS a young cow 2 lactation readouts over 300 units were obtained for all quarters but a difference suggests that the quarter C may be subclinically inflamed Further tests of that cow are necessary quarter A 370 quarter B 380 quarter C 310 a difference of 70 units compared to the maximum result quarter B quarter D 370 a middle aged cow 5 lactation results indicate that one quarter D is at risk of inflammation therapy should be started and the cow should be further observed 14 quarter A 340 quarter B 350 quarter C 350 quarter D 260 result below 300 units and a difference of 90 units compared to the highest result quarters and an old cow 9th lactation for one quarter B the readout is below 300 units but it is rather common in cows at that age all is physiologically normal quarter A 310 quarter B 290 resu
14. water is hard high iron calcium phosphorus salts content electrode cleaning is particularly important After degreasing a measuring cup should be thoroughly rinsed with running water e In the case of abnormal excessively high readouts degrease electrodes first e General principles of hygiene should be observed when making measurements e housing of the device may be cleaned with a damp cloth using mild detergents The procedure should be completed directly after the end of a session of tests Do not use hot or boiling water for cleaning e device should be stored in a dry place optimally at room temperature e After the end of the warranty period the Manufacturer offers maintenance and service of the device at a fee e Considering valid zoo sanitary requirements lending the device to other farmers is not recommended 16
15. will not affect the measurement of another quarter After a cow has been tested it is recommended to note the principle conclusion or mark it with a symbol Is the udder completely healthy or is there a suspicion of the disease 13 INTERPRETATION OF RESULTS IT IS NECESSARY TO EVALUATE RESULTS ACCORDING TO TWO CRITERIA 1 What is the value obtained from the tests of quarters and is it typical for the tested cow individual evaluation considering the age of a cow 2 What are the differences between the quarters in a tested cow Regarding item 1 Readings below 250 units Indicate clear subclinical inflammation of a quarter of an udder or high risk of transition into an acute condition which may be rapid Readings over 300 units good condition of a quarter of an udder Usually results fall within the range of 330 360 units In young and healthy cows results may be higher 370 400 and in older cows they may be lower 300 320 Readings from 250 to 300 units a transitional state between subclinical mastitis and a normal condition Due to physiological differences it is difficult to define a strict border value the exceeding of which indicates the disease of a quarter of an udder In some cows a readout between 250 and 300 units is considered normal especially if no higher values are obtained from that individual cow In that case a quarter should be considered normal However if in a cow for which normal values exceeded 300 u