1. A IP 54 NEMA Type 12 350 450 A1 IP 54 NEMA Type 12 350 450 HP 7 T gus 1270 0 IP 20 NEMA Type 1 4 00 381 0 254 0 50 00 IP 54 NEMA Type 12 250 300 HP y gt C e 15 0 gt 10 0 gt 10 o l A Ze 5 2286 0 nz 90 00 A gt Allow lt DRIVE OPTION DRIVE OPTION 152 4 ENCLOSURE ENCLOSURE 6 00 SUPPLIED AS for STANDARD le Air Flow X e le E Y le 762 0 508 0 635 0 30 00 20 00 25 00 50 8 Option Mounting Location a 406 4 eat 90 8 2 00 16 00 200 Mountable CB CF CP CT DS D1__ D2_ D3_ D5_ E__ 061 Option List D91 GM C GD C GMS C HA__ HJ__ HN__ JC o GM_C GD_C 0 HA__ HJ__ HN__ JF JR JT K_ L__ L___ M M__ N3_ N__ UL 279 4 LE E 11 00 Consult Factory JL JS LQ LT LR LW MP12N MP18A MP12A MP18N Option List 02 1 Removable Lifting Angle lt 26 00 gt lt 2 00 Vented Areas 20 NEMA Type 1 Only gm 160 5 Air Conditioner IP54 NEMA Type 12 350 450 HP 0nly 350 HP Dimension is actually 139 7 5 50 Special Smaller Enclosure 11 56 7 50 i 3 E
2. WITH OPTION BAY 1194 47 00 1067 42 00 dimensions in millimeters and inches 914 36 00 762 WITHOUT OPTION BAY 30 00 610 610 24 00 TENA 24 00 457 457 18 00 18 00 305 1336 PLUS II 305 1336 PLUS u 1200 DRIVE STD 12 00 DRIVE STD 152 152 6 00 EE 6 00 To 0 0 0 152 305 457 610 662 0 152 305 457 610 662 6 00 12 00 18 00 24 00 26 05 6 00 12 00 18 00 24 00 26 05 DRIVE CIRCUIT BREAKER OR DISCONNECT SWITCH Q DRIVE INPUT CONTACTOR D BYPASS MOTOR FUSES CONTROL TRANSFORMER DRIVE OUTPUT CONTACTOR D AUTO BYPASS LOGIC O RELAY LOGIC VARIES BYPASS CONTACTOR MOTOR GROUND TERMINAL COMMUNICATION OPTION CARD DRIVE OR PANEL MOUNTED OVERLOAD RELAY LINE GROUND TERMINAL INPUT ISOLATOR D BYPASS CIRCUIT BREAKER OR DISCONNECT SWITCH SIGNAL GROUND TERMINAL 93 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Panel Layouts Pre engineered P options include the following catalog numbers AA D10 D31 6 5 HNSBC LA2C AF D11 D32 6M6C HNSPC LA3C AJ D12 D41 6MS1C HNS1C LA4C BA D13 D42 GMS2C HNS2C LA5C BM D14 D51 GMS5C JC LA6C CB D15
3. WITH 0PTION BAY 1550 61 02 1372 54 00 1000 48 00 All dimensions in millimeters and inches 1000 42 00 WITHOUT BAY 914 36 00 900 35 43 762 762 30 00 80 00 1336 PLUS II 6 PLUS II DRIVE STD STD 24 00 Ns 457 18 00 ean 305 305 12 00 12 00 152 152 6 00 6 00 pe 0 0 152 305 457 610 762 800 0 152 305 457 610 762 800 6 00 12 00 18 00 24 00 80 00 31 50 6 00 12 00 18 00 24 00 80 00 31 50 DRIVE CIRCUIT BREAKER OR DISCONNECT SWITCH INPUT ISOLATOR CONTROL TRANSFORMER Q DRIVE INPUT CONTACTOR RELAY LOGIC VARIES DRIVE OUTPUT CONTACTOR COMMUNICATION OPTION CARD DRIVE OR PANEL MOUNTED Q BYPASS CONTACTOR NEXT PAGE 96 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Panel Layouts C Frame Drives 230V 15 22 kW 20 30 HP 460V 30 45 kW 40 60 HP 575V 18 5 45 kW 25 60 HP IP54 NEMA Type 12 IP65 NEMA Type 4 Consult Allen Bradley when adding additional heat producing components to existing NEMA Type 4 or 12 rated drives 1930 76 00 1829 72 00 1676 66 00 1524 60 00 1372 54 00 1194 48 00 1067 42 00
4. lt 22 2 0 88 Conduit Knockout 1 Plc Input Catalog kW HP Voltage Frame Number Rating al 22 2 28 6 0 88 1 13 230 A4 F75 5 5 7 5 Conduit Knockout 3 Plcs 40 M F5 5 5 7 5 0 7 F100 7 5 10 150 11 15 1 0 1 200 15 20 575 A4 F30 2 2 3 F50 3 7 5 NML 75 5 5 7 5 F100 7 5 10 F150 11 15 F200 15 20 i Y y v Fans will be present on A4 Frame Frame Reference L M N P 0 R 1 111 8 105 4 86 3 31 0 69 1 102 1 135 4 440 415 3 40 1 22 2 72 4 02 5 33 A2 132 3 126 0 106 9 31 0 69 1 102 1 135 4 5 21 4 96 4 21 1 22 2 72 4 02 5 33 A3 158 8 1524 133 4 31 0 69 1 102 1 135 4 6 25 6 00 5 25 1 22 2 72 4 02 5 33 M 164 0 164 0 139 0 27 0 65 0 97 0 128 7 6 45 6 45 5 47 1 06 2 56 3 82 5 07 Frames B and lt 5 gt R ih g 28 6 34 9 1 13 1 38 P Z Conduit Knockout 3 Plcs 22 2 0 88 Conduit Knockout 1 Plc I oc ET All Dimensions in Millimeters and Inches 9 92575 4 XX ML GG Frame Reference L M P 0 R 1 2 181 6 167 1 112 8 163 6 214 4 249 9 7 15 6 58 4 44 6 44 8 44 9 84 C 181 6 167 1 119 1 182 6 233 4 275 3 7 15 6 58 4 69 7 19 0 19 10
5. PE V W 2 3 72 T3 Y Dynamic Brake n To Motor H To Motor Li Cy I 1 Required Branch Required Circuit Disconnect Input Fusing AC Input Line 200 240V 15 22 kW 20 30 HP Terminal Designations 380 480V 30 45 kW 40 60 HP Terminal Designations 500 600V 18 5 45 kW 25 60 HP Terminal Designations GRD GRD R S T 0 U V qi 2 L3 m 2 13 T or d d To Motor WA DC Input Line To Motor Required Required Branch Input Fusing Circuit Disconnect T AC Input Line Dynamic Brake Important A brake malfunction will occur if the Dynamic Brake is connected to DC COM 200 240V 7 5 11 kW 10 15 HP Terminal Designations 380 480V 15 22 kW 20 30 HP Terminal Designations 500 600V 15 kW 20 HP Terminal Designations 011110111107 OOO OJO DG DC R S T U V 0 2 3 2 T Dynamic Brake A A A Required 1 Input Fusing To Motor
6. Option Must Be Used With Cannot Be Used With Option Must Be Used With Cannot Be Used With A208 230V Base Drives 460 or 5 5V Base Drives HABC AA AF AJ GD1C GD2C GU6C HAPC HA1C HA2C AF AJ HJPC HJ2C HJPC HJ2C AF AJ 10 2 HAPC AA AJ GD1C GD2C GUBC HA1C HA2C AJ HA2C 4 A B P BM B i a HAIC AA AJ 010 017 018 019 GD1C GD2C GUBC BD JF BA BC BM BP BS KM MK MT HAEC HAPC HAZC HJPC 2 BM JF BA BC BD BP BS KM MK MT HA2C AA AF AJ 010 017 018 019 GD1C GD2C GUEC BP JF BA BC BD BM BS KM MK MT HABC HAPC HA1C HJPC HJ2C BS JF BA BC BD BM BP KM MK MT HNSBC HNSPC HNS1C HNS2C GMS1C GMS2C CB DS 6 5 CC one BA BC BD BM BP or BS DT HNSPC HNSBC HNS1C HNS2C GMS1C GMS2C 6 5 CM ee HNS1C HNSBC HNSPC HNS2C GMS1C GMS2C DS CB HNS2C HNSBC HNSPC HNS1C GMS1C GMS2C D one BA BC BD BM BP or BS CC GMSSC D10 011 019 HATC HA2C HJ2C HJPC AF or AJ GDIC GD2C GUBC Di D10 D12 D19 HA2C HJ2C 7 17 HJ2C AFor AJ AA 010 017 018 019 GD1C GD2C GU6C d IS bs ars 36130 HA2C HJ2C 015 010 014 016 019 016 010 015 017 019
7. 135 Door Radius Y CONDUIT ACCESS Top or Bottom Three Phase Ratings All Dimensions in Millimeters and Inches gt p 74028 gt lt 79031 12 7 0 50 12 7 0 50 14 3 0 56 A A A A Mounting Slots Mounting Holes Option Mounting Location DRIVE OPTION All Option Codes Not Listed Below ENCLOSURE EXPANDED OPTION Option Codes BA BM CC D41 D42 DT JS ENCLOSURE CONSULT Option Codes BC BD BP BS CM JL LQ FACTORY LR MP12A MP12N MP18A MP18N MQ2 MQ3 Approximate Shipping Weights All Weights Kilograms and Pounds Drive Option D rive Option and Enclosure Only Expanded Option Frame 230V 460V 575V Al A2 B1 B2 Enclosures 1 0 37 3 7 0 37 3 7kW 655 0 630 0 600 0 500 0 1000 0 475 0 975 0 35 65 0 5 5 0 5 5 25 79 24 80 23 62 19 69 39 37 18 70 38 39 75 140 M orB 5 5 11kKW 5 5 22kW 0 75 15 kW 655 0 630 0 600 0 650 0 1150 0 625 0 1125 0 60 110 4 or 7 5 15HP 7 5 30HP 1 20 25 79 24 80 23 62 25 59 45 28 24 61 44 29 130 243 C 15 22kW 30 45kW 19 45 kW 855 0 830 0 800 0 900 0 1550 0 875 0 1525 0 95 145 20 30HP 40 60 25 60 HP 33 66 32 68 31 50 35 43 61 02 34 45 60 04 210 320 86 Artisan Technology Group Quality Instrumentation
8. Group Param No Disp Units Min Max Values Default Frequency Setup continued Pulse In Scale 264 Factor 1 4096 1024 PPR Encoder PPR 46 Factor 1 4096 1024 PPR Dwell Frequency 43 01 Hertz 0 0 7 0 Hz 0 0 Hz Dwell Time 44 1Second 0 10 Sec 0 Sec Speed Control 77 Settings Selection Parameter Slip Comp Slip ELA 42 0 1 Hertz 00 100 7 1 0 Hz Slip Comp Gain 95 None 1 40 1 Run OnPowerUp 14 Settings Selection Parameter Disabled Reset Run Tries 85 1Ty 0 9 0 Tries Reset Run Time 5 0 1 Second 0 5 30 0 Sec 1 0 Sec S Curve Enable 57 Settings Selection Parameter Disabled S Curve Time 56 0 1 Second 0 0 1800 0 Sec 0 0 Sec Language 4 Settings Selection Parameter English Flying Start En 55 Settings Selection Parameter Disabled FStart Forward 56 1Hz 0 400 Hz 60 Hz FStart Reverse 57 1Hz 0 400 Hz 0Hz LLoss Restart 228 Settings Selection Parameter Track Volts LLoss Mode 256 Settings Selection Parameter LoBus gt Off LLoss Volts 320 1 Volt 40 80 100 Volts 200 400 500 Volts 50 117 146 Volts Loss Recover 321 1 Volt 20 40 50 Volts 200 400 500 Volts 29 59 73 Volts Ride Thru Volts 322 1 Volt 40 80 100 Volts 200 400 500 Volts 29 59 73 Volts in Bus Volts 323 1 Volt 100 200 250 Volts 200 400 500 Volts 194 388 485 Volts Traverse Inc 78 0 01 Sec 0 00 30 00 Sec 0 00 Sec Traverse Dec 304 0 01 Sec 0 00 30 00 Sec 0 00 Sec ax Traverse 79 0 01 Hz 0 00 50 Maximum Freq 0 00
9. G QI QTM RSEN So 62 Q IQ I QO 9 G PE PE DC DC R S T U v W GRD GRD tt 2 3 T 3 Dynamic Brake A A A Required Input Fusing To Motor 1 Motor Disconnect AC Input Line 1 Required Branch Circuit Disconnect T AC Input Line 1 User supplied 2 Terminal located separately on Series A Drives 37 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Power Wiring TB1 Terminal Designations 200 240V 30 45 kW 40 60 HP 380 480V 45 112 kW 60 150 HP Terminal Designations 500 600V 56 112 kW 75 150 HP Terminal Designations eno DC DC PE Brake Brake To Motor T V W L1 L2 L3 T1 T2 T3 1 Required Branch Circuit Disconnect olololallc ioo To Motor 1 Required Input Fusing See Appendix B for detailed Dimensions AC Input Line 200 240V
10. 20 7 87 MOUNT TE BUSS LEFT OF OTHER COMPONENTS 200 7 87 400 15 75 600 23 62 N N N N N N N N 2 gt gt gt S 6 5 S Q F NS G o o VFB G 2 8 Se ODN BDH G M This page of the drawing package provides all the necessary enclosure information including dimensions conduit access operator devices and location and panel layout The actual drive system data nameplate is also shown on this sheet this is helpful for customers who might have multiple drives in one location and need to quickly match up the correct documentation for each actual drive by comparing nameplates 115 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Drawing Sample ge 5 P List and Interconnection Wirin 86 00 70 86 20 40 ON 9 1 5 1000 79 1000 31dWVS 9 m9 1511 SLYVd 2 3MIM LOSNNOOYALNI LO ES JAYA OV NILATING 193NNOOH3LNI DESCRIPTION PART NO E 86 80 80 uw Qvov N DRIVE UNIT 115VAC CNTRL CIRCUIT PROT FUSE FUSE CTRL TFMR H 0 A SEL SW A M SEL SW PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT PILOT LIGHT DRIVE DISABLE HIM MODULE RELAY RELAY RELAY RELAY DRV OFF BYP AUT BYP ENABL RELAY CONTACTOR
11. 0 5 AFO5C TA 28 0 9 23 075 7 14 35 12 30 1 AF10C 22 54 18 45 15 AF15C 29 13 24 6 0 2 AF20C 3 9 97 32 8 0 3 AF30C 5 7 14 3 48 12 5 AF50C 85 21 8 72 18 75 007 10 12 28 1 27 10 A010C 12 14 35 14 34 15 015 17 20 49 19 48 20 A020C 22 26 63 26 65 25 A025C 26 31 75 31 77 30 A030C 27 33 79 32 80 40 A040C 41 49 119 48 120 50 A050C 52 62 149 60 150 60 060 62 74 178 72 180 75 A075C 82 99 238 96 240 100 100 100 120 289 116 291 125 A125C 112 134 322 128 325 Drive Specifications 460V Constant Torque Input Input Output Output 1 2 1 2 5 2 4 2 1 2 2 20 42 5 48 42 4 3 CF30C 6 2 7 5 72 6 2 6 5 0 8 3 10 9 6 8 3 8 75 007 9 11 10 10 10 10 C010C 11 13 12 12 12 15 C015C 17 20 19 19 19 20 020 21 26 25 24 24 25 025 27 32 31 30 30 30 C030C 31 37 36 35 35 40 C040C 38 45 44 45 45 50 050 48 57 55 57 57 60 C060C 52 62 60 62 62 75 075 73 88 84 85 85 100 100 94 112 108 109 109 125 156 118 142 137 137 138 150 C150C 144 173 167 167 168 200 200 216 260 250 252 252 250 250 244 293 282 283 384 300 300 256 307 295 297 300 300 300 258 309 297 299 300 350 350 301 361 347 349 350 400 400 343 412 397 398 400 450 450 386 464 446 448 450 500 500 429 515 496 498 500 600 600 515 618 595 598 600 Constant Torqu
12. Run On Power Up For applications that require unattended operation the 1336 PLUS II offers the ability to resume running once power is restored after a power outage If Run On Power Up is activated and input power is lost when power is restored the drive will automatically restart and run at current command speed if all required signals are present Enable Auxiliary Not Stop and Start Traverse Period P Jump S P Jump J UNE Reference A Maximum Traverse Traverse P Jump 10 20 30 40 50 60 Seconds Output Frequency Power Lost Power Restored Time 4 20mA Loss Select Many control systems issue a 4 20 mA control signal for the drive to use as a speed reference The drive will run at minimum speed with a 4 mA signal and maximum speed with a 20 mA signal The drive can also invert this signal to run minimum speed at 20 mA and maximum speed at 4 mA Since a minimum signal of 4 is required the drive must have a fall back instruction in the event of a signal loss failed transducer or broken wire The 1336 PLUS II contains a loss select parameter that offers five choices for signal failure mode 1 Stop the drive and issue a fault 2 Go to minimum speed and issue a warning 3 Go to maximum speed and issue a warning 4 Maintain speed and issue a warning 5 Go to a preset speed and issue a warning 16 Drive at Com
13. 32 Power Wiring 1 36 Control and Signal Wiring 2 40 General Wiring Information 40 Terminal Block 2 41 Terminal 41 Encoder Inputs i c tdt eC RE Gs 45 Pulse Input Output eee ene 46 Digital OUTPUTS pak vegies cakes wes 46 Analog Inputs Outputs 47 Motor 65 50 User Supplied Enclosures 55 Derating 56 1336 PLUS II Remote Device 61 1336 PLUS II SELECTION 63 Catalog Number Explanation 63 Constant Variable Torque Drives and Enclosures 64 Language 65 Dynamic Brake 5 65 Factory Installed Optlons n ooh e bebe 66 Field Installed 67 Standard Packaged Drives Program 69 119 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Product Description Protective Special Function Detection and Trip Auto
14. Option D51 9 Use with Drive Output Contactor amp Drive Enable Option D52 6 For Use with Drive Enable Only Pon Speed By Drive Enable 1 Turn Option Set D6 amp Drive Enable Option D61 Speed 1 Turn NEMA 1 4 12 1 Refer to Operator Device Function Guide in the Options section Option Set D9 2 D22 must be used in conjunction with a Thermal Overload or Bypass Option Option D91 Convert the normally supplied A B Bulletin 800E Style 3 D41 must be used with a Manual Bypass Option 42 must be used with an Auto Bypass Option 5 051 must be used in conjunction with an Output Contactor or Bypass Option 6 052 cannot be used with a Bypass Option Operator Devices to A B Bulletin 800T Style Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options Operator Device Function Guide Drive Start Control Drive Stop Control Drive Speed Reference Pushbutton HLM Pushbutton HLM H I M Options Defined Device or Selector With Remote or Selector With Remote With Control by Drive Option Mode Switch Control Contact None Switch Control Contact None Parameter 5 Adapter1 Parameter None D10 Start Stop Jog Auto anual D11 Hand amp 0ff D12 Auto Auto anual D13 Hand 8 0ff D14 Auto D15 A
15. 80 Operator Device Functionality Meter Options Enclosure Options 81 Codes and Standards Drawing and Test Options Firmware 82 ENCLOSURE SPECIFICATIONS Installation Guidelines Enclosure Types 03 Material 5 04 Mounting and Spacing 85 DIMENSIONS NEMA 1 IP20 A C Frame 86 NEMA 4 amp 12 IP65 amp IP54 A C Frame Drives 87 NEMA 1 amp 12 IP20 amp IP54 D E Frame 08 NEMA 1 amp 12 IP20 amp IP54 F Frame 89 NEMA 1 amp 12 IP20 amp IP54 G Frame 91 o PANEL LAYOUTS DriVe tpe tails aman ain 93 Drive 95 diede dete terr etaed 96 Drive Frame 98 Drive Frame sus tace obe bee eta 99 Drive Frame 100 101 WIRE TERMINATIONS Power Terminal Block 1 102 Control and Signal Wiring Terminal Block 2 103 Control Interface Wiring Terminal Block 104 SELECTION GUIDE Catalog Num
16. 4 Carrier Frequency in kHz Guaranteed 888 88 SOURCE www artisantg com mamam Standard Rating for Enclosed Drive in 40 C Ambient amp Open Drive in 50 C Ambient Derating Factor for Enclosed Drive in Ambient between 41 C amp 50 Figure F 1336F B050 and BX060 Figure G 1336F A040 B075 C075 Figure H 1336F A050 B100 Figure 1336F C100 Figure J 1336 060 B125 BX150 Figure K 1336F C125 Artisan Technology Group Quality Instrumentation of Drive Rated Amps of Drive Rated Amps of Drive Rated Amps of Drive Rated Amps of Drive Rated Amps of Drive Rated Amps 100 100 100 100 100 95 90 85 80 75 70 65 1 2 4 Carrier Frequency in kHz 100 98 96 94 92 90 2 4 Carrier Frequency in kHz 95 90 85 80 75 70 65 i I 2 4 Carrier Frequency in kHz 98 96 94 92 90 2 4 Carrier Frequency in kHz 95 90 85 80 75 70 65 1 1 2 4 6 Carrier Freguency in kHz 95 90 85 80 75 70 65 1 1 1 2 4 40 6 Carrier Frequency in kHz Pre Installation Derating Guidelines Guaranteed 888 88 SOURCE www artisantg com Pre Installation Derating Guidelines mamam Standard Rating for Enclosed Drive in 40 C A
17. ola le 44 4 laput Fusing T 1 Required Branch 1 Line G3 DC DC typical terminal Brake Brake 380 480V 224 448 kW 300 600 HP Terminal Designations 500 600V 187 448 kW 250 600 HP Terminal Designations o o E p o olo o DC Z Z 5 3 2 L DC e a Required Brake G3 e nput Fusing Z U V w Circuit Disconnect WI AMA dum ee AC Input Line Brake terminals are located 22 behind the terminal To Motor Access terminals 0 from side of chassis typical terminal layout 1 User supplied located at top of drive located at bottom of drive 39 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Control and Signal Wiring General Wiring Information General requirements for analog signal wire include stranded copper 0 750 0 283 mm 18 22 AWG twisted pair 100 shield with drain wire 300V minimum insulation rating and a temperature rating suitable for the application not less than 60 degrees C The recommended signal analog 1 0 wire is e Belden 8760 9460 or equiv 0 750 mm 18 AWG twisted pair shielded Belden 8770 or equiv 0 750 mm 18 AWG 3 conductor shielded for remote pot only The recommended
18. 9 D52 D6 D9 EC EF 6 EH EH2 EP 208V AC Input Bypass Auto Bypass Auto SMC Pump Bypass Auto SMC Bypass Manual Bypass Manual SMC Pump Bypass Manual SMC Circuit Breaker Drive Circuit Breaker Bypass Control Power Drive Only Common Mode Core Control Power Plus 250VA Control Power Plus 500VA Disconnect Switch Drive Disconnect Switch Bypass Start Stop Jog A M H 0 A and A M Switches D11 Plus Pilot Lights Selector Switch D13 Plus Pllot Lights A M Selector Switch D15 Plus Pilot Lights Start amp Stop PBs Start Stop A M Start Stop Jog Pilot Light Package Pilot Light Package At Speed Pilot Light Fwd Rev Selector Switch Drive amp Bypass Lights Auto Bypass Enable Off On S S and Bypass PL Drive Disable PB Contactor Drive Disable PB Enable Speed Pot 800T Conversion Voltage Barrier Enclosure Filtered Door Openings Enclosure Floor Stand 12 Enclosure Floor Stand 24 Enclosure Filters and Gasketing Enclosure Heater Remote Power Enclosure Heater Local Power Enclosure Paint Special One Color 5 T CODE DESCRIPTION REUS C C LA3C LA4C LA5C LA6C LA7C 4 Enclosure Paint Special Two Color Encl Paint Special Three Color Enclosure Nameplate Fuse Block Motor Single Point RIO RS232 422 485 DF Single Point RIO RS232 422 485 DFI Devic
19. e S 2 NOT ACCEPTABLE 1 Some horizontal mounting conventions are acceptable provided the application and packaging is reviewed with Allen Bradley Input Conditioning In general the 1336 PLUS drive is suitable for direct connection to a correct voltage AC line that has a minimum impedance of 1 3 for 0 37 22 kW 0 5 30 HP drives relative to the rated drive input kVA If the line has a lower impedance a line reactor or isolation transformer must be added before the drive to increase line impedance If the line impedance is too low transient voltage spikes or interruptions can create excessive current spikes that will cause nuisance input fuse blowing and may cause damage to the drive power structure The basic rules for determining if a line reactor or isolation type transformer is required are as follows 1 If the AC input power system does not have a neutral or one phase referenced to ground Refer to Ungrounded Distribution Systems an isolation transformer with the neutral of the secondary grounded is highly recommended If the line to ground voltages on any phase can exceed 125 of the nominal line to line voltage an isolation transformer with the neutral of the secondary grounded is always required 2 If the AC line supplying the drive has power factor correction capacitors that are switched in and out an isolation transformer or 5 reactors are recommended between the capacitors and drive If th
20. 2 Wire Control Single Source Control Run Forward Stop Fault Reset 3 Wire Control Single Source Reversing Start Stop Fault Reset Individually Programmable Inputs Common Rev For Factory Default Jog Factory Default Auxiliary Factory Default Common programmable programmable programmable Speed Select 3 Factory Default programmable Speed Select 2 Factory Default programmable Speed Select 1 Factory Default programmable Common Enable not programmable 1 See Speed Select Table f this mode is selected the status of all inputs can be read at the Input Status parameter However only Stop Fault Reset and Enable will have control function 3 These inputs must be present before drive will start Bit 0 of Direction Mask must 1 to allow TB3 direction change 5 The encoder loss detection feature of the 1336 PLUS II requires the use of L7E L8E or L9E Stop contact terminal 20 will stop the drive If this contact is reclosed any fault will be reset If a valid Start ATTENTION Two wire control uses maintained Run contacts that act as both Run closed and Stop open devices Opening the command is still present the drive will restart If a three wire device i e HIM is also used pressing the HIM Stop key will also stop the drive Releasing the Stop key will clear any faults that are present but the drive will not restart without
21. F30 3 143 120 15 35 15 140M C2E C16 140M D8E C16 140M F8E C16 F50 5 213 180 25 60 30 140M C2E C25 140M D8E C25 140M F8E C25 140M CMN 2500 F75 75 226 1220 30 80 50 140M C2E C25 140M D8E C25 140M F8E C25 140M CMN 2500 B 007 75 280 1270 140 80 50 140M F8E C32 140M CMN 4000 010 10 350 340 50 100 50 140 4000 015 15 490 480 70 150 70 140M CMN 6300 C 020 20 630 650 100 200 100 140M CMN 9000 025 25 750 770 100 250 100 140M CMN 9000 030 30 790 800 125 300 150 140M CMN 9000 D 040 40 119 0 1200 120 300 150 050 50 149 0 150 0 200 350 250 060 60 1780 1800 250 450 250 075 75 2380 2400 300 500 250 100 100 2890 2910 400 700 100 125 125 13220 3250 450 800 600 _ Ratings VT Ratings Drive Dual Element Circuit Circuit Catalog Time Delay Non Time Breaker Protector 140M Motor Starter with Adjustable Current Number Input Ouput Input Ouput Fuse Delay Fuse 3 4 Range 1336F Amps Amps Amps Amps Min Max Min Amps Amps Available Catalog Numbers 140 7 A1 F05 05 13 11 05 14 12 3 25 3 3 15 3 C2E B16 F07 0 75 20 16 075 21 1 7 3 3 3 6 15 3 C2E B25 F10 1 26 2 1 1 28 23 3 45 3 8 15 3 C2E B40 M D8E B40 F15 15 33 28 15 3 5 3 0 4 6 4 2 15 7 C2E B40 M D8E B40 A2 F20 2 46 38 2 48 40 5 6 5 2 15 7 C2E C63 M D8E C63 _ _ F30 3 64 53 3 72 6 0 8 10 8 5
22. Consult Allen Bradley when adding additional heat producing components to existing NEMA Type 12 rated drives WITH OPTION BAY WITHOUT OPTION BAY 2286 2286 90 00 90 00 2133 6 2133 6 84 00 84 00 1981 2 1981 2 78 00 TERMINAL 78 00 TERMINAL 1828 8 1828 8 72 00 72 00 1676 4 1676 4 66 00 66 00 1524 1524 60 00 60 00 1371 6 1371 6 54 00 54 00 1219 2 1219 2 48 00 48 00 1066 8 1066 8 42 00 42 00 914 4 914 4 36 00 36 00 762 762 90 00 1336 PLUS m 36 PLU DRIVE STD RIVE STD 609 6 609 6 24 00 24 00 457 2 457 2 18 00 18 00 304 8 304 8 12 00 12 00 1524 1524 6 00 6 00 0 0 0 152 4 304 8 457 2 609 6 762 914 4 1066 8 1143 0 152 4 304 8 457 2 609 6 635 6 00 12 00 18 00 24 00 30 00 36 00 42 00 45 00 6 00 12 00 18 00 24 00 25 00 All dimensions in millimeters and inches DRIVE CIRCUIT BREAKER OR DISCONNECT SWITCH INPUT ISOLATOR CONTROL TRANSFORMER DRIVE INPUT CONTACTOR RELAY LOGIC VARIES DRIVE OUTPUT CONTACTOR COMMUNICATION OPTION CARD DRIVE OR PANEL MOUNTED
23. Guaranteed 888 88 SOURCE www artisantg com IP54 NEMA Type 12 and IP 65 NEMA TYPE 4 Dimensions For A C Frame Drives Dimensions 12 70 050 lt A gt 125 0 49 A NL Mounting Holes 2 _ see detail B2 EXPANDED OPTION ENCLOSURE G A DRIVE OPTION S 1 A ENCLOSURE 2 gt e Allen Bradley 34 p Pr wawar wana LL Di D QO O IO D Bi GSOOC PETS a sad 2 Mounting Slots 2 Y Y see detail 9 fu ini Y Y 135 Door Radius y CONDUIT ACCESS Top or Bottom Three Phase Ratings 404 gt 1 59 2 Additional Mounting Holes Not Present When EXPANDED OPTION ENCLOSURE Is Required Y 548 4 21 59 5080 20 00 EXPANDED ENCLOSURE Lifting Holes 2 Frames M B amp C Only ENCLOSURE DRIVE OPTION NOTE IP 65 NEMA Type 4 will have waterproof gasketing system and drive option mounting chassis gt lt 71028 12 7 0 50 Y E 14 3 0 56 A Mounting Holes Option Mounting Location DRIVE OPTION ENCLOSURE 12 7 0 50 _ 19030 f Mounting Slots All Option Codes Not Listed
24. m ze gt T e SMC Bypass 0ptions 6 8 BS BD BP or BC ej os ROS C 73 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options Drive Input Fuses Standard Power Disconnect Options This is a standard feature of all packaged drive assemblies except for frames A E with the circuit breaker option CB These fuses provide branch circuit protection in the drive mode of operation If a bypass option is included then separate branch circuit protection may be supplied by the customer or by specifying option FM Refer to AC Line Fusing in the Drive Specifications section for specific fuse rating information Drive Circuit Breaker Option CB This option provides branch circuit protection for frames A E and is for disconnecting power only for frames F G amp Standard drive input fuses see above supply branch circuit protection for frames G amp H Most ratings will utilize a motor circuit protector MCP type breaker Where MCP s are not available a molded case switch will be provided All switches include handle operators door interlocking and are padlockable Thermal magnetic type breakers are not required since this type of protection is already supplied in the drive Drive Disconnect Switch Option DS An Allen Bradley Bulletin 194R
25. 00000000 DEFAULT DEFAULT DEFAULT MAXIMUM VOLTAGE MAX RATED DEFAULT DATA IN D2 DEFAULT Ki PROCESS DEFAULT MOP INCREMENT 1 1 HZ SEC DEFAULT DATA OUT A1 DEFAULT KP PROCESS DEFAULT JOG FREQUENCY 10 0_HZ DEFAULT DATA OUT A2 DEFAULT PI NEG LIMIT DEFAULT ANALOG OUT O SEL FREQUENCY DEFAULT DATA OUT B1 DEFAULT PI POS LIMIT DEFAULT PRESET FREQ 1 0 0 HZ DEFAULT DATA OUT B2 DEFAULT PI PRELOAD 0 00 HZ DEFAULT PRESET FREQ 2 0 0 HZ DEFAULT DATA OUT C1 DEFAULT SHEER PIN FAULT DISABLED DEFAULT PRESET FREQ 5 0 0 HZ DEFAULT DATA OUT C2 DEFAULT ADAPTIVE 1 LIMIT ENABLED DEFAULT ACCEL TIME 2 10 0 SECS DEFAULT DATA OUT D1 DEFAULT LLOSS RESTART TRACK VOLTS DEFAULT DECEL TIME 2 10 0 SECS DEFAULT DATA OUT D2 DEFAULT FREQ REF SqROOT DISABLED DEFAULT SKIP FREQ 3 400 HZ 400 HZ DEFAULT DEFAULT DEFAULT PROCESS 1 DEFAULT DEFAULT DEFAULT CURRENT LMT SEL CURRENT LMT DEFAULT DEFAULT DEFAULT SKIP FREQ BAND 0 HZ DEFAULT PROCESS DEFAULT ANALOG OUT 0 Abs ENABLED DEFAULT CURRENT LIMIT 150 DEFAULT PROCESS DEFAULT ANLG OUT O LO 0 0 DEFAULT OVERLOAD MODE NO DERATING DEFAULT PROCESS DEFAULT OUT O HI 100 0 DEFAULT OVERLOAD AMPS 115 R
26. 1981 2 78 00 1828 8 72 00 1676 4 66 00 1524 60 00 1371 6 54 00 1219 2 48 00 1066 8 42 00 9144 86 00 762 80 00 609 6 24 00 4572 18 00 304 8 12 00 1524 6 00 0 2 BAY WITHOUT BYPASS E BRANCH FUBING IS IT ON THE DRIVE TERMINAL BLOCK 1336 PLU DRIVE STD 1524 3048 4572 6096 762 6 00 1200 18 00 24 00 30 00 36 00 42 00 48 00 PREVIOUS PAGE O MOTOR PE LINE GROUND TERMINAL SIGNAL GROUND TERMINAL 9144 2286 80 00 2133 6 84 00 1981 2 78 00 1828 8 72 00 1676 4 66 00 1524 60 00 1371 6 54 00 1219 2 48 00 1066 8 42 00 9144 36 00 762 30 00 609 6 24 00 457 2 18 00 304 8 12 00 152 4 6 00 0 3 BAY WITH BYPASS IDEI E Bi IANCH FUSING IS IT ON THE DRIVE TERMINAL BLOCK 1336 PLU DRIVE STD 1524 3048 4572 6096 762 9144 10668 12192 13716 1524 16764 18288 1981 2 6 00 12 00 18 00
27. 24 00 30 00 36 00 42 00 48 00 54 00 60 00 66 00 72 00 78 00 dimensions in millimeters and inches BYPASS CONTACTOR B AUTO BYPASS LOGIC BYPASS CIRCUIT BREAKER OR DISCONNECT SWITCH p BYPASS MOTOR FUSES 101 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Wire Terminations Power Wiring Drive Terminal Block TB1 The TB1 Terminal Block connections shown below are a generic representation intended to show the interface of internal or remote power devices to the power terminal block Specific TB1 terminal locations may vary by standard drive rating For more information refer to the Standard Drives section The location of user cable connections to a packaged drive will vary with the particular power options chosen After an order is entered Approval Drawings or Manufacturing Drawings may be ordered prior to shipment and specific customer interconnection information is supplied 2 13 Ground Ground Dynamic Brake a cl I n Optional Configured Drive 1 Drive Output Branch Fusing Power Device Provided as Standard Configured Drive Power Disconnect To Motor or Circuit Breaker Input Line User supplied remote power disconnect the drive if opened during drive operation If opened during drive operation the drive will continue to produce output vol
28. 4 rtisan Artisan Technology Group is your source for quality Femoog Ge new and certified used pre owned equipment FAST SHIPPING AND SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT DELIVERY Experienced engineers and technicians on staff Sell your excess underutilized and idle used equipment TENS OF THOUSANDS OF at our full service in house repair center We also offer credit for buy backs and trade ins IN STOCK ITEMS www artisantg com WeBuyEquipment EQUIPMENT DEMOS HUNDREDS OF InstraV ea REMOTE INSPECTION LOOKING FOR MORE INFORMATION MANUFACTURERS Remotely inspect equipment before purchasing with Visit us on the web at www artisantg com 7 for more our interactive website at www instraview com 7 information on price quotations drivers technical LEASING MONTHLY specifications manuals and documentation RENTALS ITAR CERTIFIED Contact us 888 88 SOURCE sales artisantg com www artisantg com Allen Bradley Technical Data 1336 PLUS Adjustable Frequency AC Drive A ro 7 MT SENSORLESS VECTOR NS po Rockwell Automation SOURCE www artisantg com Complete Line of Drives for Complete Family of Products Available in ratings from 0 37 to 448 kW 0 5 to 600 horsepower the drive helps to provide a single solution for virtually all of your speed control requirements Commonality of design across the entire ra
29. 705 0 Detail A 1 0 28 Dia me 14 3 0 56 Dia See Detail B 12 7 0 50 Dia Detail B pz 19 1 0 75 Dia Frame Approx Ship Reference A E F Weight 1 430 0 500 1 250 0 16 8 16 93 20 67 13 78 15 94 19 69 9 84 37 0 A2 430 0 525 0 350 0 404 9 500 1 250 0 N A N A 17 9 16 93 20 67 13 78 15 94 19 69 9 84 39 4 430 0 525 0 350 0 404 9 500 1 250 0 N A N A 18 6 16 93 20 67 13 78 15 94 19 69 9 84 41 0 M 655 0 650 0 425 0 629 9 625 1 293 0 63 5 76 2 39 5 25 79 25 59 16 74 24 80 24 61 11 54 2 50 3 00 87 0 B1 5 5 kW 7 5 HP at 200 240V AC 655 0 650 0 425 0 629 9 625 1 293 0 63 5 76 2 44 7 11 kW 15 HP at 380 480V AC 25 79 25 59 16 74 24 80 24 61 11 54 2 50 3 00 98 5 B2 7 5 11 KW 10 15 HP at 200 240V AC 655 0 900 0 425 0 629 9 875 0 293 0 63 5 76 2 56 5 15 22 kW 20 30 at 380 480V 25 79 35 43 16 74 24 80 34 45 11 54 2 50 3 00 124 5 C 655 0 1200 0 425 0 629 9 1174 5 293 0 63 5 76 2 80 7 25 79 47 24 16 74 24 80 46 22 11 54 2 50 3 00 178 0 26 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation IP 20 NEMA Type 1 Bottom View Dimensions Frames A C Fans are present on these drives Frames A1 through A4 lt S
30. H2 JR one of CF CP CT H ET K BC BD BM BP BS MT FM one BA BC BD BM BP or BS MT BA BC BD BM BP BS MK GD1C GM1C GMS1C GD2C GU6C 12 LR LT MP12N MP18A MP18N HA1C HA2C HJBC HJPC HJ2C 12 P12A MP18A MP18N GD2C GM2C GMS2C GD1C GUBC PISA LR LT MP12A MP12N MP18N HA1C HA2C HJBC HJPC HJ2C MION PON EA GM1C GD1C GM2C GM5C GMS1C Frame A Drives GM2C GD2C GM1C GM5C 6MS2C Frame A Drives 03 GM5C GM1C GM2C GMS5C Frame A Drives 03 02 GM6C GMIC GM2C 6 5 GU6C GMS6C Frame A Div GMSIC GDIC GM1C GMS2C GMS5C HNSBC HNSPC 3 1422 LABC LA7C NAT N5C NGT HNS1C HNS2C 4C LAC LAGC LA7C 3 NSC NST GMS2C GD2C GM2C GMS1C GMS5C HNSBC HNSPC AT LA2C LAGC LA7C N3 4 N5C N5T HNS1C HNS2C 5 LAZC LAEC LAC NAT NST GMSSC ree ree GMS2C HNSBC HNSPC LA2C LAGC LATC 3 NAC GMS6C GM6C GMS1C GMS2C GMS5C HNSBC GU6C BA HNSPC HNS1C HNS2C 7A 6A NGA GUGC 24V DC user supplied power GM6C GMS6C GD1C GD2C 8A 6A N7A HA1C HA2C HJBC HJPC HJ2C UL 111 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Drawing Sample Page 1 Drive and Power Distribution Each Packaged Drive ships with a set of order specific computer generated schematics Though a given drive pac
31. OUTPUT FREQ DEFAULT RUN BOOST 0 15 DEFAULT PROCESS 2 TXT 2 DEFAULT PULSE OUT SCALE 64 DEFAULT RESET RUN TRIES 0 DEFAULT PROCESS 2 TX DEFAULT ENCODER LOSS SEL DISABLED DEFAULT ANALOG TRIM EN DISABLED DEFAULT PROCESS 2 DEFAULT QUICK STOP LIMIT 150 DEFAULT LOW BUS FAULT ENABLED DEFAULT DEFAULT BUS REGULATION DISABLED DEFAULT LOGIC MASK 11111111 DEFAULT PROCESS 2 DEFAULT PHASE 1055 DET DISABLED DEFAULT LOCAL MASK X1111111 DEFAULT PROCESS 2 TXT 7 DEFAULT LOAD LOSS DETECT DISABLED DEFAULT NOTE THE READ ONLY PARAMETERS NOT LISTED FOR MORE INFORMATION REFER TO PUBLICATION 1336 PLUS 5 3 N o LOAD LOSS LEVEL 50 DEFAULT LOAD LOSS TIME 0 SEC DEFAULT ACAD 08 28 98 woos TRS wr 7 02 98 wo wr 7 02 98 PROJECT M x N 9 31 3 m C SAMPLE 0001 1 mM mom m AC DRIVE 8 T 5 CONFIGURATION PARAMETER LISTING V1 004 FOR BULLETIN 1336 PLUS factory default values and the ive ded for the user to enter h f the parameters the normal Standard Dr ist 0 Standard Packaged Drive factory default values Extra room ides a li ings page provi The Parameter Sett lled i
32. STANDARD DEFAULT 38 39 SHIPPED SETTING DEFAULT 40 4 INSTALLED SETTING FREQ SELECT 2 PRESET 1 ADAPTER 6 START MASK X1111111 DEFAULT MOTOR NP VOLTS MAX RATED DEFAULT ACCEL TIME 1 10 0 SECS DEFAULT JOG MASK 1111111 DEFAULT MOTOR NP AMPS MAX RATED DEFAULT DECEL TIME 1 10 0 SECS DEFAULT REFERENCE MASK 1111111 DEFAULT FLUX AMPS REF 0 0 AMPS DEFAULT CONTROL SELECT SENS VECTOR DEFAULT ACCEL MASK 1111111 DEFAULT AMPS 100 DEFAULT STOP SELECT 1 COAST DEFAULT DECEL MASK X1111111 DEFAULT IR DROP VOLTS 0 VOLTS DEFAULT BUS LIMIT EN DISABLED DEFAULT FAULT MASK 1111111 DEFAULT SLIP COMP GAIN 1 DEFAULT DC HOLD TIME 0 SEC DEFAULT MOP MASK 1111111 DEFAULT FLUX UP TIME 0 0 SEC DEFAULT DC HOLD LEVEL 0 DEFAULT DATA IN A1 DEFAULT MOTOR OL FAULT ENABLED DEFAULT RUN ON POWER UP DISABLED DEFAULT DATA IN A2 DEFAULT VT SCALING DISABLED DEFAULT RESET RUN TIME 1 0 SEC DEFAULT DATA IN B1 DEFAULT GROUND WARNING DISABLED DEFAULT MINIMUM FREQ 0 0 HZ DEFAULT DATA IN B2 DEFAULT ALARM MASK 1 111111111111111 DEFAULT BASE FREQ 60 HZ MAX RATED 60 HZ DEFAULT DEFAULT DEFAULT DATA IN C1 DATA 01 DEFAULT DEFAULT DEFAULT CONFIG
33. sm e 717 6 28 25 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation IP 20 NEMA Type 1 amp Open Dimensions Frame G 63 5 2 50 Removable Lifting Angle Y Chassis Dimensions Depth 508 3 20 01 Weight 453 6 kg 1000 Ibs 117 3 4 62 2324 1 91 50 1524 0 60 00 Y Y 648 0 762 0 o 6350 _ 19 3 25 51 30 00 25 00 0 76 Important Two 2 725 CFM fans are required if an open type drive is mounted in a user supplied Conduit enclosure Access Area All Dimensions in Millimeters and Inches See Bottom View Dimensions for Details 27 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation IP 65 54 NEMA Type 4 12 Dimensions See Detail A AB Allen Bradley Typical Top and Bottom Drive Heatsink All Dimensions in Millimeters and Inches All Weights in Kilograms and Pounds 9 0 31 gt lt A 12 7 0 50 12 4 0 49
34. 12 250 300 HP A 2 Three Phase Ratings All Dimensions in Millimeters and Inches DRIVE OPTION DRIVE OPTION BYPASS OPTION ENCLOSURE ENCLOSURE ENCLOSURE X e 762 0 508 0 au 762 0 x 30 00 20 00 30 00 26 00 gt lt 2 00 d 6 00 4 00 2 00 X D M 7 50 26 00 gt je 26 00 gt lt 2 00 400 gt lt 1600 4 00 11 56 7 50 9 3 50 0 625 DIA 6 MTG HOLES lt 15 00 gt 25 00 lt 25 00 101 6 4 00 c1 381 0 254 0 15 0 gt lt 0 0 gt n 0 2286 0 90 00 j b 635 0 25 00 Option Mounting Location Mountable Option Codes From Previous Option List Page Plus BA BM CC D41 D42 DT FM Consult Factory Option Codes From Previous Option List Page Plus BC BD BP BS 12 MP12N MP18A MP18N MQ2 MQ3 Removable Lifting Angle Vented Areas 20 NEMA Type 1 Only Air Conditioner IP54 NEMA Type 12 350 450 HP Only 350 HP Dimension is actually 139 7 5 50 Approximate Shipping Weights All Weights in Kilograms and
35. 16 1 10 220 15 16 1 75 220 1 100 BRF100 AA BRF100 AE BRF100 AF 100 AJ 240 15 240 15 240 11 24 0 11 50 BRF150 AA 150 AE BRF150 AF BRF150 AJ 270 20 270 20 27 0 15 210 15 BRF200 AN 200 AA 200 AE BRF200 AF BRF200 AJ 242 15 27 20 242 11 27 15 B015 Al B015 AA B015 AE 015 015 AJ 31 20 34 25 31 15 34 18 5 020 020 B020 AE B020 AF B020 AJ 3 2 42 30 39 185 42 22 025 025 B025 AE B025 AF B025 AJ 45 30 48 30 45 22 48 22 B030 A B030 AA B030 AE B030 AF B030 AJ 59 40 59 40 59 30 59 30 BX040 AN BX040 AA BX040 AE BX040 AF BX040 AJ 60 40 65 50 60 30 65 37 B040 AN B040 AA B040 AE B040 AF B040 AJ 75 5 75 60 75 37 75 45 B050 A B050 AA B050 AE 050 AF B050 AJ 7 60 77 60 77 45 7 45 BX060 AN 060 4 BX060 AE 4 BX060 AF 4 BX060 AJ 4 85 60 96 75 85 45 96 56 B060 AN 060 B060 AE 3 3 108 75 120 100 106 56 120 75 075 075 B075 AE 3 3 138 100 150 125 138 75 150 93 100 A B100 AA B100 AE 3 3 173 125 180 150 173 93 180 112 125 125 B125 AE 3 3 180 150 180 150 180 112 180 112 BX150 AN 150 AA BX150 AE 3 3 199 150 240 200 199 112 240 149 150 150 9 B150 AE 9 3 3 263 200 292 250 263 149 292 187 B200 AN 200 B200 AE 9 3 3 32
36. 4 A single 762 mm 30 In wide enclosure may be used if the option list m 2 requirements below met Consult factory for custom quotation in all cases gt i Any combination of 1 69 3 50 CM 010 091 EC EP 6010 GD2C GM1C GM2C GM5C JC JF JM JR 0 625 DIA 6 MTG HOLES JT L4C L5C L4EC L5EC L6EC LA C ME all HIMs and a max of 1 CF EB N3 NAC N5C NOT or lt 15 00 lt 25 00 gt Approximate Shipping Weights All Weights in Kilograms and Pounds Three Phase Ratings All Dimensions in Millimeters and Inches Drive and Drive Option Enclosures 460V CT 460 575V A2 C1 IP 20 NEMA Type 1 IP54 NEMA Type 12 F 187 224 kW 224 kW 139 7 624 624 250 300 HP 300 HP 11 5 50 1375 1375 325 360 360 REQUIRED 261 336 KW 261 336 261 298 kW 16574 14224 234 9 2159 624 805 350 450 HP 350 450 350 400 HP 65 25 56 0 9 25 8 50 1375 1775 425 525 A 425 525 A 425 475 A 89 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Dimensions IP20 NEMA Type 1 and IP54 NEMA Type 12 Dimensions for F Frame Drives with Bypass gt Allow 152 4 6 00 for Air Flow A IP 54 NEMA Type 12 350 450 HP 1 IP 54 NEMA Type 12 350 450 HP 2032 0 IP 20 NEMA Type 1 80 00 54 NEMA
37. 78 00 78 00 1828 8 1828 8 72 00 DRIVE BRANCH FUSING IS 72 00 DRIVE BRANCH FUSING IS RESIDENT ON THE DRIVE RESIDENT ON THE DRIVE 16764 um 16764 66 00 pipe 66 00 TERMINAL 1524 1524 im 60 00 TD 60 00 T 1371 6 1371 6 54 00 54 00 1219 2 1219 2 48 00 1386 PLU 48 00 1336 PLU IVE S IVE S 1066 8 1066 8 42 00 42 00 914 4 914 4 36 00 36 00 762 762 30 00 30 00 609 6 609 6 24 00 24 00 457 2 457 2 18 00 18 00 304 8 304 8 12 00 12 00 1524 1524 6 00 6 00 0 0 0 1524 3048 4572 6096 762 9144 10668 12192 0 1524 3048 4572 6096 762 9144 10668 12192 13716 1524 16764 18288 19812 6 00 1200 1800 24 00 30 00 36 00 42 00 48 00 6 00 1200 18 00 24 00 30 00 36 00 42 00 48 00 54 00 60 00 66 00 72 00 78 00 All dimensions in millimeters and inches DRIVE CIRCUIT BREAKER OR DISCONNECT SWITCH INPUT ISOLATOR CONTROL TRANSFORMER DRIVE INPUT CONTACTOR RELAY LOGIC VARIES DRIVE OUTPUT CONTACTOR COMMUNICATION OPTION CARD DRIVE OR PANEL MOUNTED OVERLOAD RELAY 100 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Panel Layouts G Frame Drives 460V 224 448 kW 300 600 HP 575V 224 448 kW 300 600 HP IP20 or IP54 NEMA Type 1 or NEMA Type 12 Consult Allen Bradley when adding additional heat producing components to existing NEMA Type 12 rated drives 2286 90 00 2133 6 84 00
38. 914 36 00 7622 30 00 610 24 00 457 18 00 305 12 00 152 6 00 WITH OPTION BAY 1336 PLUS II DRIVE 5TD TERMINAL BLOCK STD 0 152 305 457 610 762 918 6 00 1200 18 00 24 00 30 00 36 15 PREVI0US PAGE OVERLOAD RELAY BYPASS CIRCUIT BREAKER OR DISCONNECT SWITCH D BYPASS MOTOR FUSES All dimensions in millimeters and inches WITHOUT OPTION BAY 1194 48 00 1067 42 00 914 36 00 1336 PLUS II DRIVE STD 7622 30 00 610 24 00 457 18 00 305 12 00 TERMINAL 6 BLOCK STD 0 152 305 457 610 762 918 6 00 12 00 18 00 24 00 30 00 36 15 AUTO BYPASS LOGIC MOTOR GROUND TERMINAL LINE GROUND TERMINAL SIGNAL GROUND TERMINAL 97 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Panel Layouts D Frame Drives 230V 30 45 kW 40 60 HP 460V 45 112 kW 60 150 HP 180A 575V 56 93 kW 75 125 HP IP20 or IP54 NEMA Type 1 or NEMA Type 12
39. Guaranteed 888 88 SOURCE www artisantg com Motor Thermal Overload Relay Data Selection Guide The Thermal Overload Relay Option will have the following characteristics Class 10 Bulletin 193 Relays Class 20 Bulletin 592 Relays e Trip in 10 seconds or less at 600 of device current rating e Have integral heater elements Additional heater elements are not required e Have auto or manual reset e Have trip settings per the range chart shown below e f a motor outside the published adjustability range is to be used complete motor data must be supplied at order entry CLASS 10 ADJUSTABLE THERMAL OVERLOAD RELAY OPTION CODE MT DRIVE RATING ADJUSTABLE RANGE kW HP 230V 460V CT 460V VT 0 37 0 5 6 24A 1 6 A 1 6 A 0 56 0 75 2 4 4 A 1 6 A 1 6 A 0 75 1 46 6 24A 6 24A 1 6 2 4 A 1 2 1 5 46 2 4 4 A 2 4 4 A 1 5 2 6 10A 2 4 4 A 2 4 4 A 2 4 4 A 2 2 3 0 16 46 46 46 3 7 5 6 24 0 16 6 10A 6 10 A 5 5 7 5 8 30 A 0 16 A 0 16 A 6 10 A 7 5 10 30 45 0 16 0 16 10 16 11 15 45 60 6 24 6 24 16 24 15 20 60 75 A 8 30 8 30 16 24 18 5 25 70 90 30 45 30 45 18 30 A 22 30 70 90 A 30 45 45 60 A 30 45 A 30 40 80 120 A 45 60 A 45 60 A 30 45 A 37 50 120 200 A 60 75 A 60 75 A 45 60 A 45 60 120 200 A 70 90 A 70 90 A
40. maximum of one GD Series Options are panel mounted and require 120V AC power GU Series Options are panel mounted and require 24V DC power 7 For more information refer to the Standard Drives section Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options PLC and SLC Control Options PLC Hardware and Mounting 2 This options provides PLC hardware mounted in the drive or option enclosure Option JL Option includes a maximum of 4 Position Rack 1771 A1B 16 Amp Power Supply 1771 P1 no programming included SLC 500 Hardware and Mounting 1 2 This options provides SLC 500 hardware mounted in the drive or option enclosure Option JS Option includes a maximum of 4 Position Rack 1746 A4 Power Supply 1746 P1 No programming included Control Interface Options All 1336 PLUS II Packaged Drives come with a 115V AC Control Interface Card Option L6 as standard unless otherwise specified 24V AC DC control and Contact Closure control are available as options Encoder feedback is also available as an option with any of the three control methods All control interface cards provide input terminals for access to fixed drive functions that include start stop auxiliary fault line loss output contactor close speed select sync traverse reset and enable Additional inputs are programmed for functions such as reverse preset speed access jog second accel decel t
41. o Va Disconnect fi Option DT O Option CC Drive Circuit Breaker Motor i Drive Option CB Circuit Branch Drive Fusing Disconnect Breaker Option Option DS Drive Branch Fusing O 2 i Std 6 O Circuit Breaker la pe s Drive Branch H Drive Branch i ranc i i Option CB 12 and 18 Fusing Fusing Std Fusing Std Pulse Option Drive Branch 2 Input Contactor Input Contactor Drive Branch i 3 12 FM Option KD4 T Option KD H Fusing Std H Fusing Std xi MP12N P i MP18A Input Contactor MP18N Option KD L Output Contactor T T Bypass Bypass y y 8 Thermal Overload Relay 6 Thermal Overload Relay Output Line Reactor Options Options Option MK or MT Option MK or MT Option LQ or LW BA or BM BA or BM Bypass System Bypass System Oy Circuit Non Fused Breaker Disconnect Option CC 0ption DT Circuit Breaker Circuit Breaker DOR MG O Disconnect Option CB Motor Branch Option CB Motor Branch 0ption DS3 Fusing H Fusing H 0ption Option FM SMC SMC Drive Branch Fusing Drive Branch Fusing Drive Branch Fusing Std 9 Fusing Std 6 Fusing Std Input Contactor Input Contactor Input Contactor 7T Option KD 4 7T Option KD4 Option KD sw L se Pus PUS mnm ah
42. 0 22 6 8 8 22 A007 10 12 28 8 8 22 A010 12 14 35 14 34 A015 17 20 49 19 48 A020 22 26 63 26 65 A025 26 31 75 31 71 030 21 33 79 32 80 A040 41 49 119 48 120 A050 52 62 149 60 150 A060 62 74 178 72 180 A075 82 99 238 96 240 A100 100 120 289 116 291 A125 112 134 322 129 325 E BRF05 0 9 1 0 1 1 BRFO7 1 3 1 6 2 13 1 6 BRF10 17 21 2 6 1 7 2 1 BRF15 22 26 3 3 2 2 2 8 BRF20 30 37 46 3 0 3 8 BRF30 42 51 64 42 5 3 BRF50 6 6 8 0 10 0 6 7 84 BRF75 8 9 11 3 13 6 10 6 13 3 BRF100 10 8 13 6 16 4 12 8 16 1 BRF150 16 1 20 4 24 5 19 1 24 BRF200 18 23 28 22 2 B015 16 21 25 19 24 2 B020 21 26 32 25 31 B025 26 33 40 31 39 B030 30 38 46 36 45 BX040 40 50 61 47 59 B040 38 48 58 48 60 B050 48 60 73 60 75 BX060 62 75 61 77 B060 54 68 82 68 85 B075 69 87 105 84 106 B100 90 114 137 110 138 B125 113 143 172 138 173 150 148 178 143 180 150 130 164 197 159 199 200 172 217 261 210 263 250 212 268 322 259 325 250 212 268 322 259 325 250 212 268 322 259 325 300 235 297 357 287 360 BP BPR300 235 297 357 287 360 B350 277 350 421 339 425 BP BPR350 277 350 421 339 425 400 310 392 471 387 415 BP BPR400 310 392 471 378 415 450 343 433 521 418 525 BP BPR450 347 438 527 424 532 500 385 486 585 470 590 B600 437 552 664 534 670 1480 Volts Only 8 Variable Torque Input Input Output Output kVA Amps Amps 240V Drives 14 28 0 9 2 3 14 3 5 1 2 3 0 2 2 54 1 8 4 5 2 9 73 24 6 0 3 9 97 32 8 0 5 7 14 3 48 1
43. 030 A030C AJ D 40 120 0 040 040 A040C AJ 50 150 0 A050C AA 050 050 60 180 0 A060C AA 060 060 75 240 0 A075C AA 075 075 100 292 0 100 100 A100C AJ 125 325 0 125 A125C AF A125C AJ NEMA Type 1 IP20 4 IP65 12 1 54 Drive Rating General Purpose Resists Water and Dust Industrial Use Dust Tight Nominal HP Code Code Code Al 1 2 11 BFOSC AA BFOSC AF BF05C AJ 3 4 1 6 BFO7C AA BFO7C AF BFO7C AJ 1 24 BF10C AF 11 2 28 BF15C AA BF15C AF BF15C AJ A2 2 3 8 20 BF20C AF BF20C AJ 3 5 3 BF30C AA BF30C AF BF30C AJ A3 5 84 BF50C AA BF50C AF BF50C AJ 4 71 2 14 0 BF75C AA BF75C AF BF75C AJ 10 17 5 BF100C AA BF100C AF BF100C AJ 15 240 BF150C AA BF150C AF BF150C AJ 20 210 BF200C AA BF200C AF BF200C AJ B1 15 242 B015C AA B015C AF B015C AJ B2 20 310 B020C AA 020 B020C AJ 25 39 0 025 025 B025C AJ 30 45 0 B030C AA 030 030 C 40 59 0 B040C AA 040 B040C AJ 50 75 0 B050C AA 050 050 60 710 BX060C AA BX060C AF BX060C AJ D 60 85 0 B060C AA 060 060 75 106 0 B075C AA B075C AJ 100 138 0 B100C AA B100C AJ 125 173 0 B125C AA B125C AJ 150 180 0 BX150C AA BX150C AJ 150 199 0 B150C AA B150C AJ 200 263 0 B200C AA B200C AJ 250 325 0 B250C
44. 1336 PLUS II is powered up Throughout the entire run sequence the drive will continue to look for potential fault conditions To allow real time preventive maintenance drive output current and control conditions can be selectively monitored while the drive is running The operator is made aware of alarm conditions such as current limit bus voltage status motor overload or drive overload before the drive reaches a fault level Should a fault occur plain language diagnostic messages will help identify and isolate the problem allowing personnel to take quick corrective action Packaging Small size conserves expensive panel space Planer Construction eliminates most internal cables and connectors Increases reliability Laminar Bus Design reduces internal inductance thereby reducing snubber losses and improving IGBT performance Removable Human Interface provides simplicity of programming and flexibility of operation Thermal Dissipation Management Design and extensive infra red testing minimizes hot spots to maximize reliability NEMA and European standards Designed for acceptability throughout the world IP 65 amp 54 NEMA Type 4 amp 12 configurations accommodated with heat sink through the back design IGBT s Insulated Gate Bipolar Transistors Quiet motor operation through programmable carrier frequency Third Generation devices Reduced switching and conduction losses Used on complete line 0 37 448
45. 25 7 C2E C10 M D8E C10 M F8E C10 A3 F50 5 100 84 5 107 90 12 15 12 30 35 15 C2E C16 M D8E C16 M F8E C16 4 75 75 136 133 10 157 154 20 30 20 50 50 30 C2E C16 M D8E C16 M F8E C16 F100 10 164 16 1 15 224 220 30 40 30 80 80 30 C2E C25 M D8E C25 M F8E C25 CMN 2500 F150 15 245 240 20 245 240 35 60 35 100 100 50 C2E C25 M D8E C25 M F8E C25 CMN 2500 F200 20 280 270 20 1280 270 35 60 35 00 100 50 M F8E C322 CMN 4000 B 015 15 250 24 2 20 280 270 35 60 35 00 100 50 M F8E C32 CMN 4000 020 20 320 310 25 1350 340 45 70 45 125 125 50 M F8E C45 CMN 4000 025 25 400 390 30 430 420 60 90 60 150 150 70 M F8E C45 CMN 6300 030 30 460 450 30 490 480 70 90 70 50 150 70 CMN 6300 C X040 40 610 590 40 610 590 80 110 80 200 200 70 CMN 6300 040 40 580 60 0 50 63 0 650 80 125 80 250 250 100 CMN 6300 050 50 730 750 60 750 770 100 150 100 300 300 100 CMN 9000 X060 60 750 77 0 60 750 77 0 100 150 100 300 300 100 CMN 9000 D 060 60 820 850 75 930 960 125 200 125 350 350 150 075 75 105 0 106 0 100 119 0 120 0 150 250 150 450 350 250 100 100 137 0 1380 125 149 0 1500 200 350 200 600 450 250 125 125 172 0 1730 150 1780 180 0 250 400 250 600 500 250 X150 150 1780 180 0 150 178 0 1800 250 400 250 600 500 25
46. 3 350 261 350 350 C350 AN C350A AA9 3 3 400 298 400 400 CA00 AN CA00A AAS 3 3 450 336 450 450 C450 AN C450A AAS 3 3 500 373 500 500 C500 AN C500A AAS 3 3 600 448 600 600 C600 AN C600A AAS 3 3 Language Group Used Option Code Description With Language All Drives English EN French FR German DE Italian IT Japanese JP Spanish ES Dynamic Brake Kits Used Catalog Number Catalog Number Description With Complete Brake Brake Chopper for 200 240V AC Drives 0 37 3 7 kW 0 5 5 HP 6 KA005 WA018 5 5 7 5 kW 7 5 10 HP 6 KA010 WA018 11 22 kW 15 30 Hp 6 NA WA070 30 56 kW 40 75 HP 6 NA WA115 for 380 480V AC Drives 0 37 3 7 KW 0 5 5 HP 6 KB005 WB009 5 5 7 5 kW 7 5 10 HP 6 KB010 WB009 11 37 kW 15 50 HP KB050 WB035 45 149 kW 60 200 HP NA WB110 for 500 600V AC Drives 0 37 3 7 KW 0 5 5 HP 6 005 WC009 5 5 7 5 kW 7 5 10 HP 6 KC010 WC009 11 30 kW 15 40 HP KC050 WC035 37 149 kW 50 200 HP 6 NA WC085 1 Drive rating is based on nominal voltage and carrier frequency at altitudes of 1000 meters or less Refer to the Derating Guidelines on Pages 57 61 VT HP ratings are valid for 240V or 480V only 3 Not available in this rating 480 Volts only 5 A Language Group must be specified with each drive for User Manual 6 Multiple kits may be utilized together to obtain higher ratings Refer to the appropriate brake publication 1336 5 64 or 5 65 for
47. 400 250 200 200 251 0 2520 350 400 350 600 500 250 250 250 282 0 2840 400 500 400 700 700 400 X300 300 295 0 298 0 400 600 400 800 800 400 F P350 350 3470 350 0 450 Semiconductor fuse supplied with drive P400 400 397 0 4000 500 Refer to the 1336 Spare Parts list publication 1336 6 5 for replacement information 6 300 300 297 0 300 0 400 350 350 347 0 3500 450 400 400 3970 4000 500 Bussmann FWP SPP 170M Series 450 450 446 0 4500 600 630 Ferraz Shawmut A 700 A 700S or A070URD Series 500 500 496 0 500 0 800 600 600 595 0 600 0 800 1 Minimum protection device size is the lowest rated device that supplies maximum protection without nuisance tripping 2 Maximum protection device size is the highest rated device that supplies drive protection 3 Circuit Breaker inverse time breaker 4 Motor Circuit Protector instantaneous trip circuit breaker 5 Bulletin 140M with adjustable current range should have the current trip set to the minimum range that the device will not trip 6 Manual Self Protected Type E Combination Motor Controller UL listed for 208 Wye or Delta 240 Wye or Delta 480Y 277 or 600Y 347 Not UL listed for use on 480V or 600V Delta Delta systems 7 The AIC ratings of the Bulletin 140M Motor Protector may vary See publication 140M SG001B EN P 35 Artisan Technology Group Quality Instrumentation Guar
48. 56 pes e 17 50 11 75 PERS 1 i 1 i 381 0 635 0 i 429 15 00 25 00 gt X 15 87 0 625 Dia 88 9 1 69 Mounting Holes 4 3 50 Three Phase Ratings All Dimensions in Millimeters and Inches 101 6 4 00 2286 0 90 00 635 0 25 00 Option Mounting Location CB CF CP CT DEC DS D1_ D2_ D3_ D5_ E_ 061 091 GM C GD_C GMS_C HA__ HJ__ HN__ ITC JC JF JM JR JT K L L M M__ N3 N__ UL Consult Factory JL JS LQ LT LR LW MP12A MP12N MP18A MP18N Option List 02 MQ3 Mountable Option List Special Smaller Enclosure A single 762 mm 30 In wide enclosure may be used if the option list requirements below are met Consult factory for custom quotation in all cases Any combination of CM D10 D91 EC EP ET GD1C GD2C GM1C GM2C GM5C JC JF JM JR JT L4C L5C L4EC L5EC L6EC LA_C all HIMs and a max of 1 CF EB EH N2 N3 N4C N5C NST Removable Lifting Angle Vented Areas 20 NEMA 1 Only Air Conditioner 54 NEMA Type 12 Only Approximate Shipping Weights All Weights in Kilograms and Pounds Drive and Drive Option Enclosures Frame 460V CT 460V VT 575V A 1 A2 IP 20 NEMA Type 1 IP54 NEMA Type 12 G 224 261 kW 224 261 kW 224 261 KW 2103 1 1798 3 264 2 139 7 624 805 300 350 HP 300 350 HP 300 350 HP
49. 60 75 56 75 180 300 66 110 A 66 110 A 66 110 A 75 100 180 300 A 120 200 A 80 120 A 80 120 A 93 125 240 400 A 120 200 A 120 200 A 120 200 A 112 150 D Frame 120 200 120 200 112 150 E Frame 180 300 120 200 149 200 180 300 180 300 180 300 187 250 292 240 400 180 300 180 300 187 250 325 A 240 400 A 180 300 224 300 240 400 A 240 400 A 180 300 261 350 378 630 378 630 240 400 298 400 378 630 378 630 240 400 336 450 378 630 378 630 378 630 373 500 378 630 A 378 630 A 378 630 A 448 600 645 975 A 645 975 A 378 630 A e Trip in 20 seconds or less at 600 of device current rating Must be manually reset Can be programmed for Class 20 operation by choosing the appropriate heater elements from the A B Industrial Control Catalog Publication A113 or the chart on the next page Can also be programmed for Class 10 and 30 operation by choosing the appropriate heater elements from the A B Industrial Control Catalog Publication A113 109 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Selection Guide Heater Element Selection The Thermal Overload Relay Option MK will require the addition of thermal overload heater elements These elements are not available as part of the Packaged Drives Program The Class 20 chart shown below is supp
50. 90 80 1 1 1 I 0 1 000 2 000 3 000 4 000 m 3 300 6 600 9 900 13 200 ft Altitude 100 90 80 1 1 1 1 1 2 4 6 8 10 Input Voltage Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS II Remote Device Distances Total cable length between each device and the drive must be 10 meters 33 feet or less HIM or Other Remote Device sagas B 22 2220222227227 22 Maximum Cable Length in Meters 10 X Total cable distance between each device amp drive must be 10 meters 33 feet or less Pre Installation Maximum Cable Length in Meters 10 X Length X Meters Port Expansion Option 1203 5062 HIM or Other Remote Device Cable Length 10 Meters 61 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisanig com Pre Installation Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS II Selection Guide 1336 PLUS Selection Guide Fa 3j Mele Y WLLL LLL t HLM P DT ze Catalog Number Explanation 1336F 007 AA EN 1 6 HAST GM1 BULLETIN NO VOLTAGE RATING ENCLOSURE LANGUAGE CONTROL HUMAN COMMUNICATION MUST BE SPECIFIED MUST BE SPECIFIED 1 INTERFACE INTERFACE CARD OP
51. 91 4 91 4 91 4 30 5 30 5 91 4 61 0 91 4 229 1829 2 2 25 40 300 300 300 300 300 00 00 300 200 300 75 600 2 75 22 43 1829 914 82 3 82 3 30 5 30 5 914 61 0 829 229 182 9 5 25 4 375 600 300 600 600 00 00 300 200 600 75 600 0 75 75 22 43 1829 182 9 82 9 82 9 30 5 30 5 914 61 0 829 229 82 9 25 40 375 600 600 600 600 00 00 300 200 600 75 600 0 37 16 22 43 82 9 182 9 82 9 82 9 30 5 30 5 91 4 61 0 829 229 182 9 0 5 25 40 375 600 600 600 600 00 00 300 200 600 75 600 22 22 16 22 914 914 182 9 82 9 82 9 2718 82 9 3 3 25 40 300 300 600 600 600 75 600 5 7 6 12 2 43 1829 182 9 82 9 82 9 229 82 9 2 25 40 35 600 600 600 600 75 600 0 75 75 122 43 82 9 1829 1829 82 9 229 1829 1 25 40 375 600 600 600 600 75 600 0 37 75 12 2 43 1829 182 9 82 9 82 9 2710 82 9 0 5 25 40 375 600 600 600 600 75 600 37 37 7 6 12 2 43 1829 1829 82 9 229 1829 5 5 25 40 375 600 600 600 75 600 22 75 122 43 1829 1829 82 9 229 1829 3 25 4 375 Note 600 600 600 75 600 1 5 75 22 43 F TESTE 182 9 82 9 82 9 0240 82 9 2 25 Q0 75 ications 600 600 600 75 600 075 76 122 e29 1020 Use 1204 TFB2 229 1829 1 25 40 375 randa 600 600 600 75 600 0 37 75 122 43 Ropa 82 9 82 9 82 9 228 82 9 05 098 MO 0871 otage reflection 800 600 600 75 600 M 55 15 55 15 16 22 43 are necessary You 182 9 82 9 82 9 244 82 9 7 5 20 7 5 20 29 40 375 should observe 600 600 600 80 600 B 1 22 11 22 75 122 43 standard practices 182 9 82 9 8
52. AF A025 AJ 80 2 30 30 A030 AN A030 AA A030 AF A030 AJ 120 0 40 40 A040 AN A040 AA 3 3 50 7 50 50 A050 AN A050 AA 3 3 80 45 60 60 A060 AN A060 AA 3 3 240 56 75 75 A075 AN A075 AAS 3 3 291 75 100 100 100 100 AA9 3 3 325 93 125 125 125 125 AA9 3 3 80 480V Drive Rating Drive Rating Open NEMA 1 NEMA Type 1 Type4 Type 12 Constant Torque Variable Torque Constant Torque Variable Torque 00 IP20 IP20 IIP65 IP54 Amps HP Amps HP Amps kW Amps kW No Enclosure General Purpose CE C tick Conformance Resist Water Dust Industrial Use 11 05 12 05 14 0 37 12 0 37 5 5 BRFO5 AE BRFO5 AF BRFO5 AJ 16 075 17 015 1 6 0 56 17 0 56 7 BRF0O7 AA BRF07 BRF07 AF BRFO7 AJ 243 1 23 1 24 0 75 23 0 75 AN 1 AA BRF10 AE BRF10 AF BRF10 AJ 28 15 3 0 15 28 12 3 0 112 BRFIb AN 15 15 15 BRF15 AJ 38 2 40 2 38 15 40 15 BRF20 AN 20 BRF20 AE BRF20 AF BRF20 AJ 53 3 60 3 53 22 6 0 22 BRF30 AN BRF30 AE BRF30 AF BRF30 AJ 84 5 90 5 84 37 9 0 37 50 AN BRF50 AA BRF50 AE BRF50 AF BRF50 AJ 133 75 154 10 133 55 15 4 75 BRF75 AN BRF75 AA 75 75 BRF75 AJ
53. BYPASS CONTACTOR D NEXT PAGE 98 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com E Frame Drives 230V 56 93 kW 75 125 HP 460V 11 Panel Layouts 87 kW 150 199A 250 HP 575V 112 224 kW 15 IP20 or IP54 NEMA Type 1 or NEMA Type 12 Consult Allen Bradley when adding additional heat producing components to existing NEMA Type 12 rated drives 2286 90 00 2133 6 84 00 1981 2 78 00 1828 8 72 00 1676 4 66 00 1524 60 00 1371 6 54 00 1219 2 48 00 1066 8 42 00 914 4 36 00 762 30 00 609 6 24 00 4572 18 00 304 8 12 00 152 4 6 00 TERMINAL BLOCK WITH OPTION BAY DRIVE 1336 PLUS II STD 1524 304 8 4572 6096 762 9144 10668 12192 1371 6 1397 0 6 00 12 00 18 00 24 00 30 00 36 00 42 00 48 00 54 00 55 00 2286 90 00 2133 6 84 00 1981 2 78 00 1828 8 72 00 1676 4 66 00 1524 60 00 1371 6 54 00 1219 2 48 00 1066 8 42 00 9144 36 00 762 30 00 609 6 24 00 4572 18 00 304 8 12 00 1524 6 00 dimensions in millimeters and inches O
54. Below EXPANDED OPTION Option Codes BA BM CC D41 D42 DT JS ENCLOSURE CONSULT FACTORY Option Codes BC BD BP BS CM JL LQ LR MP12A MP12N MP18A MP18N MQ2 Approximate Shipping Weights All Weights in Kilograms and Pounds All Dimensions in Millimeters and Inches Drive Option Drive Option and Enclosure Only Expanded Option 230V 460V 575V A2 1 B2 C1 C2 Enclosures 1 0 37 3 7 0 37 3 7 kW 6647 639 8 609 6 685 8 11938 407 9 100 1 6609 1168 9 50 79 0 5 5 0 5 5 26 17 25 19 24 00 27 00 47 00 16 06 3 94 26 02 46 02 110 175 Mor B 5 5 11kKW 5 5 22kW 0 75 15kW 918 7 893 8 863 6 939 8 15494 3759 1320 9149 15245 77 129 7 5 15HP 7 5 30 HP 1 20 HP 36 17 35 19 34 00 37 00 61 00 14 80 5 20 36 02 60 02 170 285 C 15 22 kW 30 45 19 45kW 918 7 893 8 863 6 13208 19304 3759 132 0 1295 9 1905 5 116 166 20 30 HP 40 60 HP 25 60 HP 36 17 35 19 34 00 52 0 76 0 1480 5 20 51 02 75 02 255 365 87 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Dimensions IP20 NEMA
55. CABLE LENGTH RESTRICTIONS IN METERS FEET 380V 480V DRIVES 1 No External Devices w 1204 TFB2 Term w 1204 TFA1 Terminator Reactor at Drive Motor Motor Motor Motor 1600V or A B 1329 1329R L 1850V AorB 1329 A B 1329 B or 1329 Drive Drive kW Motor kW Any Any Any Any Cable Type Any Cable Type Cable Type Any Any Any Frame HP HP Cable Cable Cable Cable Shld 3 Unshld Cable Shld3 Unshld Shld 3 Unshld Cable Cable Cable 1 0 37 0 37 122 335 914 914 30 5 61 0 30 5 61 0 914 229 82 9 0 5 0 5 40 10 300 300 00 200 100 200 300 75 600 0 75 0 75 12 2 335 914 914 30 5 30 5 30 5 30 5 914 2215 TER 1 1 40 110 300 300 00 00 100 100 300 75 600 0 37 122 335 914 914 Use 1204 TFA1 30 5 61 0 30 5 61 0 914 2218 82 9 05 40 10 300 300 00 200 100 200 300 75 600 12 12 122 33 5 914 914 30 5 30 5 61 0 61 0 914 0218 82 9 1 5 15 40 110 300 300 00 00 200 200 300 75 600 0 75 122 335 914 914 30 5 30 5 61 0 61 0 914 2219 AG 1 40 110 300 300 00 00 200 200 300 75 600 0 37 122 335 43 1219 30 5 30 5 61 0 61 0 21 9 228 82 9 0 5 40 10 375 400 00 00 200 200 400 75 600 A2 76 12 2 91 4 91 4
56. CONTACTOR OVERLOAD TIMING RELAY MOTOR FUSE CONTACTOR CIRCUIT PROT SINGL PNT RIO ANLG OPT BRD EL TIME MTR N A 161428 160912 149859 142917 MA N A NA N A N A N A N A N A N A N A N A 171754 101215 101215 101215 NA N A N A 101215 120482 120482 138475 190475 N A 119058 160912 161455 188604 165413 1336F BO30 AN EN AB 1336 L6 WES GMCP060J2C BUSSMANN KLDR7 5 BUSSMANN FNM8 HEAVY DUTY E850 3PBX AB 800EP SM32C24LX22 5 2241 0 AB 800EP PL54RL5 AB 800EP PL74RL5 AB 800EP PL74RL5 AB 800EP PL44RL5 AB 800EP PL44RL5 AB 800EP PL54RL5 AB 800EP PL54RL5 AB 800EP MT44LX02 AB 1201 HA2 AB 700 HC24A1 AB 700 HC24A1 AB 700 HC24A1 AB 700 HC24A1 5 32 241 11 AB 800EP SM224LX10 AB 700 HC24A1 AB 100 A45 AB 100 A45 AB 193 CPC45 SPR SHUH RZ7 FS3A CU 23 BUSSMAN LPJ IYPE AB 100 A60ND3 WEST GMCP060J2C AB 1336 GM1 AB 1336F LA2 KESSLER ELLIS K 1884 EXTERNAL INTERCONNECT WIRING REQUIREMENTS POWER SEE INSTRUCTION MANUAL FOR CABLE CLASSES INTERCONNECTION INFORMATION WIRE SOURCE EXPLANATION TERMINAL NO WIRE RANGE LINE PE GROUND EQMT CONDUCTOR CURR CLASS AMPS NO GRND 117 OL1 TI 10 4 Ga 1T2 OL1 T2 1T3 011 135 FRAME MTR PE AC MOTOR MCP2 L1 INCOMING MCP2 L2 460 V LINES MCP2 L3 14 4 Ga CONTROL SEE INSTRUCTION MANUAL FOR CABLE CLASSES CLASSES 5 AND 6 ARE CONTROL WIRES 15 AMPS OR LESS INTERCONNECTION INFORMATION EX
57. Carrier Frequency in kHz Figure AB 1336F C300 through C600 Enclosed Drive 40 Ambient Assumes two 2 725 CFM cooling fans for IP 20 NEMA Type 1 enclosure 100 90 80 70 60 50 40 of Drive Rated Amps Carrier Frequency in kHz 100 90 80 70 60 50 40 4 Carrier Frequency in kHz 100 90 80 70 60 50 40 2 4 Carrier Frequency in kHz Figure AA 1336F CP400 CPR450 100 90 80 of Drive Rated Amps 70 60 50 1 1 6 2 4 Carrier Frequency in kHz Figure AC 6kHZ Data Not Available at Time of Printing 100 C300 1336F C300 90 0 through C600 RatedAmps T QI s Enclosed Drive 70 C500 C450 in 41 50 C Ambient 60 C600 C30 Assumes two 2 50 725 CFM cooling fans for 40 IP 20 NEMA Type 1 enclosure 3 Carrier Frequency in kHz Altitude High Input Voltage Figure AD Altitude All Drive Ratings of Drive Rated Amps Figure AE High Input Voltage Required Only of Drive for the following drives 1336F x025 18 5 kW 25 HP at 8 kHz 1336F x030 22 kW 30 HP at 6 or 8 kHz 1336F x060 45 kW 60 HP at 6 kHz Rated Amps 240 480 or 600V Nominal 60 Artisan Technology Group Quality Instrumentation 100
58. Current Limit Capability Proactive Current Limit programmable from 20 to 160 of rated output current Independently programmable proportional and integral gain Inverse Time Overload Capability Class 10 protection with speed sensitive response Investigated by U L to comply with N E C Article 430 U L file E59272 volume 4 6 Display Specifications Local Programming and Display Panel Backlit Supertwist LCD display 2 lines 16 characters each Multi lingual display of status faults and programming Process Display provides 2 lines any 2 parameters scalable with user text Selectable Power Up display Load Specifications Requirements A balanced 3 phase inductive motor load is typical Drive power rating is based on a typical NEMA Design B 4 or 6 pole motor 10 1 second increments using a HIM or 0 01 with serial communications N Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Specifications Input Output Ratings Requirements Each 1336 PLUS II Drive has constant and variable torque capabilities Note Drive ratings are at nominal values Refer to Derating Guidelines on Pages 56 60 Constant Torque Cat Input Input Output Output No kVA Amps Amps 200 240V Drives AQF05 1 1 2 8 0 9 2 3 AQFO7 1 4 25 1 2 3 0 AQF10 22 54 1 8 4 5 AQF15 29 7 3 24 6 0 AQF20 3 9 97 32 8 0 AQF30 57 143 48 12 AQF50 8 5 21 3 72 18 AQF75 9
59. D52 GMS6C JF LA7C CC D16 D61 HABC JM L9EC CF D17 FM HAPC JR ME CP D18 GD1C HA1C JT MK CT D19 GD2C HA2C KD MT DS D21 GM1C HJPC KM N3 DT D22 6M2C HJ2C LAIC A4 Frame Drives 460V 5 5 15 kW 7 5 20 HP IP20 NEMA Type 1 WITH OPTION BAY 1000 39 37 1067 42 00 916 36 00 dimensions in millimeters and inches 762 80 00 WITHOUT OPTION BAY 650 25 59 610 610 24 00 24 00 PLUS II PLUS II E STD E STD 457 457 18 00 18 00 305 305 12 00 12 00 152 152 6 00 6 00 TERMINAL TERMINAL BLOCK STD BLOCK STD 0 0 0 152 305 457 600 0 152 305 457 600 6 00 12 00 18 00 23 62 6 00 12 00 18 00 23 62 DRIVE CIRCUIT BREAKER OR DISCONNECT SWITCH INPUT ISOLATOR O CONTROL TRANSFORMER Q DRIVE INPUT CONTACTOR RELAY LOGIC VARIES DRIVE OUTPUT CONTACTOR COMMUNICATION OPTION CARD DRIVE OR PANEL MOUNTED Q BYPASS CONTACTOR NEXT PAGE 94 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Panel Layouts B1 B2 Frame Drive
60. Economizer Undervoltage Process PI Controller Overvoltage e Traverse Function Drive Overcurrent Sel ble Faul Overtemperature electable Fault External Signal Reset amp Run Drive Output Short e Auto Restart on Power Up Ground Fault Speed Sensitive Electronic Encoder Loss Overload At temperature Load Loss Auto tuning Single Phase Step Logic Overcurrent Stall n perationa Overvoltage Stall 6 sisse Control e Six Drive Alarms Fault Reset Input e Selectable Volts Hertz Mode Multi lingual selection 1 0 Interface Control Output Contacts 2 Form A N O 2 Form C N O N C Programmable to 17 different drive variables Flexible Analog Inputs Outputs Pulse Train Input Encoder Feedback Closed Loop Speed Control High Speed Input Programmable Dual Accel Decel Profiles e Three Skip Frequencies e DC Injection Braking e Dynamic Braking e Slip Compensation e Negative Slip Compensation Droop S Curve Accel Decel Profile ine Loss Restart Mode Proactive Current Limit ast Four Event Fault Memory e Flying Start e Seven Preset Speeds Diagnostics Real time preventive maintenance coupled with customized status and fault reporting Depending upon your particular drive configuration status and fault conditions can be reported through the Human Interface Module or through the SCANport Communications Port Fault diagnostic routines are started each time the
61. Jog Owner 105 Bit 1 0 Read Only None Reference Owner 106 Bit 1 0 Read Only None Accel Owner 107 Bit 1 0 Read Only None Decel Owner 108 Bit 1 0 Read Only None Fault Owner 109 Bit 1 0 Read Only None Disp Units Min Max Values Default Artisan Technology Group Quality Instrumentation Group Param No wners continued Parameter List Disp Units Min Max Values Default MOP Owner 10 Bit 1 0 Read Only None Traverse Owner 306 Bit 1 0 Read Only None Sync Owner 309 Bit 1 0 Read Only None Local Owner 79 Bit 1 0 Read Only None Data In 8 11 118 Parameter None 0 Data Out 8 19 126 Parameter None 0 Alt Type 2 Cmd 315 Settings Selection Parameter Disabled Process 1 Par 27 Parameter None 1 Process 1 Scale 28 umeric 327757 1 00 Process 1 Txt 1 8 29 136 ASCII Code None Volts Process 2 Par 80 Parameter None 54 Process 2 Scale 81 umeric 327757 1 00 Process 2 Txt 1 8 82 189 ASCII Code None Amps Speed Control 71 Settings Selection Parameter Slip Comp Encoder Type 52 Settings Selection Parameter Quadrature Encoder PPR 46 Factor 1 4096 1024 PPR Maximum Speed 51 1 Hertz 0 400 Hz 400 Hz Motor Poles 53 1 Pole Read Only Speed KI 65 Numeric 0 20000 100 Speed KP 64 Numeric 0 20000 0 Speed Error 66 0 01 Hz 8 33 Base Frequency Speed Integra 67 0 01 Hz 8 33 Base Frequency Speed Add
62. LAC L7EC Jr 017 010 016 018 019 2 HJ2C JL JS 018 010 017 019 HA1C HA2C HJ2C JM D19 010 018 HA1C 2 HJ2C JR 02 022 JS JL D22 one BC BD BM BP BS MK or MT 021 JT D3 D32 D 032 031 BA BD BM BP BS CC DT FM M E BA BC BD BM BP BS KD KAG HAZG HRL AC LA3C LAAC LASC D4 one BA BC BD BM BP or BS D42 5 T Da2 one BA BC BD D41 BM BP BS 1426 D61 LA7C 3 NAC NAT N5C NST D5 one BA BC BD BS orKM 052 LAC LATC LASC D52 051 BA BC BD BM BP BS LMC LAC LASC 06 HAC HA2C HJ2C LA2C LA6C LA7C la LA3C LMC 09 At least 010 19 021 22 031 32 LAC 061 LA2C LA7C N3 NAC NAT NSC NGT 041 42 051 or D52 INC 061 LAZC LAGC 3 NAC NSC NGT i XXI LAC D12 D14 D16 L5C L7EC LBEC L9EC EF Wall Mounting Enclosures BOGOC B600C BOGOV BEOUV LAC LEG LBEC 1986 Frames A C C0750 CB00C EF Frames D G L7EC D12 D14 D16 LAC L5C LBEC L9EC EF2 Wall Mounting Enclosures 060 600 BOBOV B500V L8EC LAC LSC L7EC 19 Frames A C C075C C600C EF1 Frames 0 6 L9EC LAC LSC L7EC L8EC EG AJ EC LQ AA AF AJ LT LW EH JR EH2 LR AA AJ LT LW EH2 JR one of CT AF or AJ AA LR LO EST ENSSC SUN EN945C ENS1OC EN935C a HP or larger 5 HP or smaller EPI EP2 EP3 EP2 EP3 MH JR H2 EP3
63. Loss Restart In the event that a line loss condition occurs the 1336 PLUS II provides a variety of programmable selections to control the timing and method of reconnecting the motor after power returns Choices include Use flying start to determine motor speed Check for motor terminal voltage to determine motor speed Read the encoder if present Reconnect at last known output frequency Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Function Description Volts per Hertz The 1336 PLUS II offers a fully programmable Volts per Hertz mode Maximum that allows maximum performance for applications requiring multiple motors on a common drive particularly if the motors are not of equal size and type i e a 3 7 kW 5 HP and 11 kW 15 HP Voltage motor on a 15 kW 20 HP drive Base Voltage Base Frequency v 4Maximum Voltage Maximum Frequency Motor Rated b break Voltage Start Boost P Break Frequency 0 0 Frequency Motor Rated Maximum Motor Overload Protection Motor I t protection is separated from the drive power overload feature The electronic motor overload operates independently to Overload Patterns provide improved Class 10 protection Operation at full load amps w No Dorato Ge E will raise the overload to approximately 70 80 of its trip level S Overloading beyond FLA will move the value towards tripping level
64. Mode and Auto Bypass Enable On pilot lights are available option 042 Manual Bypass with SMC Plus 1 2 3 Option BS This option provides a means to manually switch a single motor from drive control to bypass across the line operation An SMC Plus solid state controller provides soft start capability when first switching to bypass operation Separate Bulletin 100 where available contactors are provided for drive output SMC output and total bypass All contactors are electrically interlocked A door mounted Drive Off Bypass selector switch is provided Optional Drive Mode and Bypass Mode pilot lights are available option 041 Automatic Bypass with SMC Plus 1 2 3 Option BD This option provides a means to manually or automatically upon a drive fault switch a single motor from drive control to bypass across the line operation An SMC Plus solid state controller provides soft start capability when first switching to bypass operation Separate Bulletin 100 where available contactors are provided for drive output SMC output and total bypass All contactors are electrically interlocked Door mounted Drive Off Bypass and Auto Bypass Off On selector switches are provided Optional Bypass Mode and Auto Bypass Enable On pilot lights are available option D42 Manual Bypass with SMC Plus Pump Option 2 3 Option BP This option provides a means to manually switch a si
65. NA NR 82 9 NR 610 3 600 200 15 NR NR 82 9 NR 82 9 NR 61 0 A 2 600 600 200 0 75 NR NR 82 9 NR 82 9 335 3 NR 61 0 82 9 1 600 600 1100 200 600 0 37 NR NR 82 9 NR 82 9 335 3 NR 61 0 182 9 0 5 600 600 1100 200 600 55 15 55 15 NR 9 82 9 914 82 9 182 9 NR 61 0 182 9 30 5 914 182 9 7 5 20 7 5 20 30 600 300 600 600 200 600 100 300 600 C 18 5 45 8 5 45 NR 9 82 9 914 82 9 82 9 NR 61 0 829 30 5 914 82 9 25 60 25 60 30 600 300 600 600 200 600 100 300 600 D 56 93 56 93 NR 9 82 9 914 182 9 182 9 NR 61 0 829 61 0 914 82 9 75 125 75 125 30 600 300 600 600 200 600 200 300 600 E 112 224 12 224 NR 9 82 9 914 82 9 82 9 NR 61 0 829 182 9 182 9 829 150 X300 150 X300 30 600 300 600 600 200 600 600 600 600 F 261 298 261 298 NR 9 82 9 914 82 9 82 9 NR 61 0 82 9 182 9 182 9 82 9 350 400 350 400 30 600 300 600 600 200 600 600 600 600 G 224 448 224 448 NR 9 82 9 914 82 9 182 9 NR 61 0 82 9 182 9 182 9 82 9 300 600 300 600 30 600 300 600 600 200 600 600 600 600 NR Vot Recommended NA Not Available at time of printing Values shown are for 480V nominal input voltage drive carrier frequency of 2 kHz and ambient temperature at the motor of 40 Consult factory regarding operation at carrier frequencies above 2 kHz Multiply values by 0 85 for high line conditions For input voltages of 380 400 or 415V AC multiply the table values by 1 25 1 20 or 1 15 respectively 2 A 3 reactor reduces motor and cable stress but may cau
66. Power option CF CP or CT see Options section 3 SMC style bypass options will include short circuit fusing for the SMC Once the motor is up to speed it is transferred from the SMC control to total across the line operation which required option FM to have branch circuit protection Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options Multi Pulse Harmonic Mitigation Option This 1336 PLUS II drive may be quoted with a multi pulse front end option for use in harmonic mitigation This feature reduces drive harmonics at the drive input that could be reflected back to the power distribution system Excessive harmonics can cause component overheating nuisance tripping and noise transfer to other load surfaces The hardware supplied with this option will include line fusing phase shifting input transformer and an AC to DC diode type converter bridge The traditional AC fed 1336 PLUS II drive will be replaced by a DC common bus equivalent Guidelines for Harmonic Specification IEEE519 1992 This is a North American standard developed from input provided by utilities electrical equipment manufacturers and power consumers Total harmonic distortion limits are recommended based upon the type of installation Important For compliance to this standard refer to the description in the specific option detailed below For more information on harmonic mitigation and the IEEE519 1992 standard ref
67. SOURCE www artisantg com Enclosures Specifications Installation Guidelines The information in the remaining sections of this document is very useful in making pre installation decisions Consideration should be given to enclosure type environment enclosure size mounting area available and mounting convention panel layouts customer wiring connection locations and extra customer mounting area terminal block descriptions what connections land where and catalog number definition how do order exactly what need Pay special attention to all footnotes and carefully read all warnings or the noncompliance to any code national local or otherwise for the proper installation of this drive or associated equipment T ALLEN BRADLEY A hazard of personal injury and or equipment exists if codes are ignored during installation ATTENTION The following information is merely a guide for proper installation The Allen Bradley Company cannot assume responsibility for the compliance contactor Both functions disable inherent or optional dynamic braking effects If hazards of injury due to contact with moving machinery or unintentional flow of liquid gas or solids exist it is the users responsibility to provide an additional hardwired stop circuit in accordance with applicable codes and standards ATTENTION The drive disable circuitry only shuts off the power transistors or opens an output Encl
68. SOURCE www artisantg com Pre Installation Motor Cables MAXIMUM MOTOR CABLE LENGTH RESTRICTIONS IN METERS FEET 500V 600V DRIVES 4 No External Devices w 1204 TFB2 Terminator w 1204 TFA1 Terminator Reactor at Drive Motor Motor Motor Motor 1600V or 1600V or 1600V or 1329R L 1329R L 1329R L A B 1329R L A B 1850V A B 1850V A B 1850V Drive Drive kW Motor kW Any Any Any Any Any Any Any Any Any Any Any Any Frame HP HP Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable M 0 75 0 75 NR NR NA NR 82 9 335 3 NR 61 0 1 1 600 00 200 0 37 NR NR NA NR 182 9 335 3 NR 61 0 182 9 0 5 600 1100 200 600 15 15 NR NR NA NR NA 335 3 NR 61 0 2 2 100 200 12 NR NR NA NR 82 9 335 3 NR 61 0 82 9 15 600 1100 200 600 0 75 NR NR 182 9 NR 82 9 335 3 NR 61 0 182 9 1 600 600 1100 200 600 0 37 NR NR 182 9 NR 82 9 335 3 NR 61 0 82 9 0 5 600 600 00 200 600 22 22 NR NR NA NR 82 9 335 3 NR 61 0 Not Recommended 3 3 600 1100 200 15 NR NR NA NR 82 9 335 3 NR 61 0 2 600 00 200 0 75 NR NR 182 9 NR 82 9 335 3 NR 61 0 182 9 1 600 600 00 200 600 0 37 NR NR 182 9 NR 82 9 335 3 NR 61 0 182 9 0 5 600 600 100 200 600 37 37 NR NR NA NR 82 9 NR 610 5 5 600 200 22 NR NR
69. SPLICING OF SHIELDED CABLES IF NECESSARY SHOULD BE DONE SUCH THAT THE SHIELD S REMAIN CONTINUOUS AND INSULATED FROM GROUND N N N N gt o a N o o SEE INSTRUCTION MANUAL FOR CABLE CLASSES CLASSES 7 THROUGH 12 ARE SIGNAL WIRES 5 AMPS OR LESS INTERCONNECTION INFORMATION BLUE GM1 1 SHLD GM1 S CLR 1 2 RIO 24 18 Ga 1770 CD OR EQUIV LL 0 6 8 4 9 6 t e This page provides a list of the non drive peripheral components contained in the system package The A B part number vendor and vendor s part number are included Also provided is a list of remote wiring interconnections required and the acceptable wire gauges for power control and signal wiring This page has a lot of useful contractor installer type information 116 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Drawing Sample N em co DESCRIPTION FREQ SELECT 1 STANDARD DEFAULT ADAPTER 1 10 11 SHIPPED SETTING ADAPTER 2 12 13 INSTALLED SETTING 14 15 16 PARAMETER 1 17 18 9 20 DESCRIPTION DIRECTION MASK 22 23 STANDARD DEFAULT 11111110 24 25 SHIPPED SETTING DEFAULT 26 27 INSTALLED SETTING 28 29 30 PARAMETER 3 32 33 34 DESCRIPTION PROCESS 2 TXT 8 35 36 37
70. further information 7 A Common Mode Choke option CM or No Common Mode Choke option NCM must be specified with each F Frame Drive 8 These units include as standard an integral EMC filter 9 This drive will not accept a Snap In HIM HASP HAST HAS2 HCS1 HCS2 65 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS Selection Guide Factory Installed Options Used Option Code Description With Installed Communication Options Frames B amp Up Single Point RIO Adapter 6 Only GM13 RS232 422 485 DF1 amp DH485 Protocol GM23 DeviceNet GM53 Enhanced DeviceNet GM63 Communication Options All Frames Single Point RIO with Snap In Cradle Adapter 1 Only GMS13 RS232 422 485 DF1 amp DH485 Protocol w Snap In Cradle GMS23 DeviceNet GMS53 Enhanced DeviceNet GMS63 Snap In Cradle Blank Plate HASB3 Control Interface All Drives Contact Closure L4 24V AC DC L5 115VAC L6 Control Interface with Encoder Feedback All Drives Contact Closure L4E 24V AC DC L5E 115V AC L6E Control Interface with Encoder Feedback All Drives Contact Closure 17 24V AC DC L8E 115V AC L9E Analog Interface Port A Choose One All Drives Two Isolated Configurable Inputs LA2 One Isolated Bi Polar Input 10V and One Isolated Themistor Input LA6 One Isolated Bi polar
71. list will be determined at time of order entry 3 For more information refer to the Standard Drives section Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options Human Interface Modules NEMA Type 1 and 12 Door Mounted HIMS Programming Panel Control Panel with Analog Speed Pot Control Panel with Digital Speed Pot Standard on all Human Interface modules Option 1 Option HA2C and HJ2C LCD Display Analog Speed Pot JogKey X Start Key Up Down Arrow Keys Speed Indicator Key Start Key Escape Key SelectKey Increment Decrement Keys Enter Key Direction LEDs Reverse Key Stop Key Direction LEDs Reverse Key Stop Key NEMA Type 1 Drive Mounted HIMS Option HNSBC Blank No Functionality Option HNSPC Program Only Option HNS1C Program Control with Analog Speed Pot Option HNS2C Program Control with Digital Speed Pot NEMA Type 1 Door Mounted HIMS Option HABC Blank No Functionality Option HAPC Program Only Option HA1C Program Control with Analog Speed Pot Option HA2C Program Control with Digital Speed Pot NEMA Type 12 Door Mounted HIMS 1 Option HJPC Program Only Option HJ2C Program Control with Digital Speed Pot Handheld A separate handheld module may be connected to the drive Maximum cable length is 33 feet 10 meters 1 Not removable from the door as with NEMA Type 1 HIMS 79 Artisan Technology Group
72. provided to allow the motor to run at base speed by operating across the line Manual Bypass 1 2 3 Option BM This option provides a means to manually switch a single motor from drive control to bypass across the line operation Separate Bulletin 100 where available contactors are provided for drive output and bypass operation and are electrically interlocked A Bulletin 193 Class 10 overload is also provided for motor protection while operating in the bypass mode refer to Motor Thermal Overload Data in the Selection Guide section A door mounted Drive Off Bypass selector switch is provided Optional Drive Mode and Bypass Mode pilot lights are available option 041 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Automatic Bypass 1 2 3 Option BA Bypass Options continued Options This option provides a means to manually or automatically upon a drive fault switch a single motor from drive control to bypass across the line operation Separate Bulletin 100 where available contactors are provided for drive output and bypass operation and are electrically interlocked A Bulletin 193 Class 10 overload is also provided for motor protection while operating in the bypass mode refer to Motor Thermal Overload Data in the Selection Guide section Door mounted Drive Off Bypass and Auto Bypass Off On selector switches are provided Optional Bypass
73. rotary switch is provided on A C frame drives A flange mount or rotary style switch 1494 F where possible is provided on D frame drives and larger With the exception of the F frame drive the drive input fuses will be resident on the switch allowing it to meet the requirements for branch circuit protection All disconnect switches are door interlocked and padlockable Drive Input Contactor Option KD An Allen Bradley Bulletin 100 contactor where available is provided between the AC line and the drive The contactor will close on power up using A B circuitry or may be alternately controlled by customer supplied remote contact closure logic Drive Output Contactor Option KM An Allen Bradley Bulletin 100 contactor where available is provided between the drive output and the motor The contactor will close on power up and open after a drive fault or loss of power Control Power Options Drive Only Control Power Option CF Provides a control power transformer mounted and wired inside the drive enclosure The transformer is rated for drive and options power only There is no additional capacity for customer use Drive Plus 250VA Control Power Option CP This option provides a control power transformer mounted and wired inside the drive enclosure The transformer is rated for drive power plus an additional 250VA at 120V AC for customer use Drive Plus 500VA Control Power Option CT This option provides a c
74. the back design wherever possible Pre defined to reduce cost and time By using pre defined and in most cases pre engineered options standardization provides consistency of product offering resulting in reduced costs shorter delivery time and ease of product installation Even in the case of custom designed drive packages generally 80 of the engineering already exists Drive Specifications General Specifications In most cases the general specifications of a standard packaged drive will match those of a stand alone drive refer to pages 18 and 19 Some items such as Agency Certification and Maximum Short Circuit Protection will be specific to the options chosen Agency Certification Refer to the Codes and Standards in the Options section Maximum Short Circuit Drive Package The short circuit interrupt capability of any standard packaged drive will be based upon the specific Current Rating combination of power options chosen 70 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Input and Output Ratings 230V Each 1336 PLUS II Drive has constant and variable torque capabilities In the case of 230V and 5 5V ratings the constant torque and variable torque ratings will be the same The listings on this page provide input and output current Artisan Technology Group Quality Instrumentation Constant Torque Input Input Output Output HP Cat No
75. wD Y 4 CC Mounting Holes 4 See Detail All Dimensions in Millimeters and Inches All Weights in Kilograms and Pounds Frame Shipping Reference C Max D 3 Y 1 BB CC Weight E Enclosed 511 0 1498 6 424 4 477 5 1447 8 16 8 40 1 195 0 901 4 151 9 186 20 12 59 00 16 71 18 80 57 00 0 66 1 61 7 68 35 49 5 98 410 E Open 511 0 1498 6 372 6 477 5 1447 8 16 8 40 1 138 4 680 0 126 3 163 20 12 59 00 14 67 18 80 57 00 0 66 1 61 5 45 26 77 4 97 360 24 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation IP 20 NEMA Type 1 amp Open Dimensions Frame F 635 0 500 Removable Lifting Angle Open Chassis 762 0 r 63 5 2 50 487 7 19 20 lt gt 30 00 Y lt 2827 gt gt 9 95 Allen Bradley 2286 0 37 9 90 00 1 49 gt 193 0 7 60 Y ES _ A 501 7 1219 2 19 75 48 00 Fan Vertical 5
76. wire for encoder inputs outputs is e Lengths less than or equal to 30 meters 98 feet Belden 9730 or equiv 0 196 mm 24 AWG individually shielded e Lengths greater than 30 meters 98 feet Belden 9773 or equiv 0 750 mm 18 AWG twisted pair shielded Signal Connections If the drive control connections are to be linked to an electronic circuit or device the common or OV line should if possible be grounded at the device source end only Important Signal Common User speed reference signals are terminated to logic common at TB2 terminal 5 This puts the negative or common side of these signals at earth ground potential Control schemes must be examined for possible conflicts with this type of grounding scheme Shield Termination TE True Earth The TE terminal block not available on 0 37 7 5 kW 0 5 10 HP A Frame drives provides a terminating point for signal wiring shields The maximum and minimum wire size accepted by this block is 2 1 and 0 30 mm 14 and 22 AWG Maximum torque is 1 36 N m 12 Ib in Use Copper wire only and always separate control and power cabling Cable Routing If unshielded cable is used control signal circuits should not run parallel to motor cables or unfiltered supply cables with a spacing less than 0 3 meters 1 foot Cable tray metal dividers or separate conduit should be used Important When user installed control and signal wiring with an insulation rating of less than
77. 0 E 150 150 197 0 199 0 200 238 0 240 0 300 500 300 700 700 400 200 200 261 0 2630 250 2900 2920 100 600 400 800 800 400 250 250 322 0 325 0 250 3220 3250 450 600 450 800 800 400 _ _ _ _ F P250 250 322 0 3250 300 3570 360 0 450 P300 300 357 0 360 0 350 4210 4250 500 P350 350 421 0 4250 400 4710 4750 600 Semiconductor fuse supplied with drive P400 400 471 0 4750 450 5270 5320 600 Refer to the 1336 Spare Parts list publication 1336 6 5 for replacement information P450 450 5270 5320 700 G 250 250 322 0 3250 300 3570 360 0 450 300 300 357 0 360 0 350 4210 4250 450 350 350 421 0 4250 400 4710 4750 500 400 400 471 0 475 0 450 521 0 5250 600 630 Bussmann Type FWP SPP or 170M Series 450 450 521 0 5250 500 5850 5900 800 Ferraz Shawmut Type 700 7005 or A070URD Series 500 500 585 0 590 0 600 6640 670 0 800 600 600 664 0 670 0 600 6640 670 0 900 34 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Recommended Protection Devices user supplied ww T Pre Installation CT Ratings
78. 0 360 00 0 00 Sec Remote CR Output 326 Settings None xxxx0000 Analog 1 0 Anlg In 0 Lo 237 01 300 0 0 0 Anlg In 0 Hi 238 01 300 0 100 0 Anlg In 1 Lo 239 0 1 300 0 0 0 Anlg In 1 Hi 240 0 1 300 0 100 0 Anlg In 2 Lo 248 0 1 300 0 0 0 Anlg In 2 Hi 249 0 1 300 0 100 096 Analog Trim En 90 Settings Selection Parameter Disabled AnlgSignalloss 250 Settings Selection Parameter Disabled 4 20mA Loss Sel 150 Settings Selection Parameter Min Alarm Anlg Out 0 Sel 25 Settings Selection Parameter Frequency Anlg Out 0 Offset 154 Disabled Selection Parameter Disabled Anlg Out 0 Abs 233 Disabled Selection Parameter Enabled Anlg Out 0 Lo 234 0 1 300 0 0 0 Anlg Out 0 Hi 235 0 1 300 0 100 096 Anlg Out 1 Sel 274 Settings Selection Parameter Current Anlg Out 1 Abs 271 Enabled Selection Parameter Enabled Anlg Out 1 Offset 2778 Enabled Selection Parameter Disabled Anlg Out 1 Lo 215 0 1 300 0 0 0 Anlg Out 1 Hi 216 0 1 300 0 100 0 Slot A Option 252 Settings Selection Parameter Standard Slot B Option 253 Settings Selection Parameter Standard Firmware 3 001 amp later Firmware 4 001 amp later Firmware 5 001 amp later Guaranteed 888 88 SOURCE www artisantg com Group Param Fault Buffer 0 86 Fault Code Fault Storage one Fault Buffer 1 87 Fault Code Fault Storage one Fault Buffer 2 88 Fault Code Fault Storage one Fault Buffer 3 89 Fault Code Fa
79. 0 BF20V AA BF20V AF BF20V AJ 3 6 0 BF30V AA BF30V AF BF30V AJ A3 5 90 BF50V AA BF50V AF BF50V AJ 4 10 175 BF75V AA BF75V AF BF75V AJ 15 25 0 BF100V AA BF100V AF BF100V AJ 20 240 BF200V AA BF200V AF BF200V AJ B2 25 34 0 B020V AA B020V AF B020V AJ 30 48 0 B030V AA B030V AF B030V AJ C 40 59 0 BX040V AA BX040V AF BX040V AJ 50 65 0 B050V AA B050V AF B050V AJ 60 710 BX060C AA BX060V AF BX060V AJ D 75 96 0 B060V AA B060V AJ 100 120 B075V AA B075V AJ 125 150 B100V AA B100V AJ 150 180 BX125V AA BX125V AJ E 200 240 B150V AA B150V AJ 250 292 B200V AA B200V AJ 250 325 B250V AA B250V AJ 300 360 BP250V AA BP250V AJ 350 425 BP300V AA BP300V AJ 400 415 BP350V AA BP350V AJ 450 532 BP400V AA BP400V AJ G 300 360 BX250V AA BX250V AJ 350 425 B300V AA B300V AJ 400 415 B350V AA B350V AJ 450 525 B400V AA B400V AJ 500 590 B450V AA B450V AJ 600 670 B500V AA B500V AJ 575V Constant and Variable Torque Drives and Enclosures 1 3 108 NEMA Type 1 IP20 NEMA 4 IP65 NEMA Type 12 IP54 Drive Rating General Purpose Resists Water and Dust Industrial Use Dust Tight Nominal HP Code Code Code A4 1 2 0 CF10C AF 2 40 CF20C AA CF20C AF CF20C AJ 3 6 0 CF30C AA CF30C AF CF30C AJ 5 8 0 CF50C AA CF50C AF CF50C AJ 71 2 10 0 75 CF75C AF CF75C AJ 10 12 0 CF100C AA CF100C AF CF100C AJ 15 19 0 CF150CAA CF150C AF CF150C AJ 20 240 CF200C AA
80. 00 7 6 131 1 180 8 719 227kg 10 88 1875 8 86 8 37 18 15 5 18 3 68 3 50 1 26 0 30 5 16 7 12 283 50 Ibs C 301 8 701 0 225 0 238 0 685 8 131 6 93 5 88 9 32 00 7 6 131 1 374 7 71 9 38 6 kg 11 88 27 60 8 86 9 37 27 00 5 18 3 68 3 50 1 26 0 30 5 16 1475 2 83 85 Ibs D 381 5 1240 0 2708 325 9 12162 813 189 5 184 9 27 94 11 94 131 1 686 836 108 9 kg 15 02 4882 10 66 12 83 4788 3 20 7 46 7 28 1 10 0 47 5 16 27 11 3 29 2401bs Artisan Technology Group Quality Instrumentation 23 Guaranteed 888 88 SOURCE www artisantg com Pre Installation IP 20 NEMA Type 1 amp Open Dimensions Frame E A a Z lt zm gt bim j Y 525 00 00000 1 1 1 e Allen Bradley P 149 L gt E A E Mounting Hole Detail I 10 4 0 41 Dia 1 1 1 z n 17 0 0 67 6 A SS 2 5 19 0 0 75 Dia BB See Bottom View Dimensions for Details 1 1 l l l l DID i oo O O Q OO E Uy
81. 1 C 0 255 C Power OL Count 84 1 0 200 otor OL Count 202 196 0 200 Last Fault 4 Fault None orque Current 162 0 1A 200 Drive Rating one Flux Current 163 0 1A 2009 Drive Rating one Output Power 3 1 200 Drv Rated Out Power one Output Curr 2 1 0 200 Rated Drv Out Curr one Elapsed Run Time 279 0 1 Hr 0 6553 5 Input Mode 241 Mode None Status Freq Select 1 5 Settings Selection Parameter Adapter 1 Accel Time 1 1 0 1 Second 0 0 3600 0 Sec 0 0 Sec Decel Time 1 8 0 1 Second 0 0 3600 0 Sec 10 0 Sec Minimum Freq 16 1 Hertz 0 120 Hz 0 Maximum Freq 19 1 Hertz 25 400 Hz 60 Hz Stop Select 1 10 Settings Selection Parameter Coast Current Limit 36 196 20 300 0 0 300 0 Rated Amps150 Current Lmt Sel 232 Settings Selection Parameter Current Lmt Adaptive Lim 227 Settings Selection Parameter Enabled Overload Mode 37 Settings Selection Parameter No Derate Overload Amps 38 0 1A 20 115 Drive Rated Amps 15 Drv Rtd VT Scaling 203 Settings Selection Parameter Disabled otor NP RPM 177 1 RPM 60 24000 RPM 1750 RPM otor NP Hertz 178 1 Hertz 1 400 Hz 60 Hz otor NP Volts 190 1 Volt 0 2 x Drive Rated Volts Div Rated Volts otor NP Amps 191 1 Amp 0 2 x Drive Rated Amps Div Rated Amps Advanced Setup inimum Freq 16 1 Hertz 0 120 Hz 0Hz Freq 19 1 Hertz 25 400 Hz 60 Hz PWM Frequency 45 2 kHz 2 8 kHz A amp B Frame Based on Drv Type 2 kHz 2 6 kHz C Frame amp up Based on Drv Type Accel Ti
82. 100 based on 14 Trip curves are provided for both hot and cold 5 o states Parameter settings include a 0 Overload Amps from the motor nameplate FLA Min Derate Motor OL Fault parameter to disable the fault condition e In addition Bit 14 Motor OL Trip of the Drive Alarm parameter is of Load Time to Trip Seconds Cold high 1 any time the existing level of output current will cause an Overload Fault to occur The overload feature remains speed sensitive with m 3 derating choices 100 Max Derate is used for motors not designed for variable speed E Min Derate is used for motors with a 4 1 speed range not 5 intended for operation below 25 of base Speed 115 0 1 No Derate is used for variable speed motors with a speed range j of Base Speed Multiple of Overload Amps capability of 10 1 or better Auto Economizer This feature combines stator flux control with an economizer routine to help the end user save energy costs The Auto Economizer monitors drive current and compares it against the full load amps Overload Amps that the user has programmed into the drive In load situations i e idle where the actual current draw of the motor is significantly less than the programmed overload amps the drive will automatically begin reducing the output voltage to the motor This minimizes flux current in a lightly loaded motor and results in a lower kW usage Artisa
83. 12 GA Sheet Steel A B Standard Gray Paint NEMA Type 1 12 40001 109 02 ASA 49 GRAY B Heatsink Frame Material Finish Finish Spec A G Aluminum Bronze Chromate 40001 058 C Enclosure Frame Material Finish Finish Spec A1 C 14 GA Sheet Steel A B Standard Light Gray Paint NEMA Type 1 40001 109 08 ANSI 49 GRAY Ds NEMA Type 4 12 1 40001 108 04 D G 12 GA Sheet Steel A B Standard Light Gray Paint NEMA Type 1 12 40001 109 02 ASA 49 GRAY Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Enclosures Specifications Mounting and Spacing Requirements Approved Mounting Methods for Wall Mounting Enclosures CEILING 152 4 mm 6 0 In ALLEN BRADLEY Approved Mounting Method Approved Mounting Methods for Floor Mounting Enclosures All Floor Mounting Style Enclosures can be mounted tight against the back wall NEMA Type 1 Floor Mounting Style Force ventilated as standard may be mounted side by side with zero clearance NEMA Type 12 Floor Mounting Style Enclosures will require six inch clearance on the sides Not Acceptable 152 4 mm 6 0 In ALLEN BRADLEY Approved Mounting Method y 152 4 mm 6 0 In FLOOR Approved Mounting Method y 152 4 mm 6 0 In E wi o fa amp 3
84. 1336 PLUS II pulse inputs or a separate 125 ohm load at TTL levels 4V at 32 mA source 0 8V at 3 2 mA sink The digital outputs are at terminals 10 through 18 of TB2 Digital Outputs TB2 CR1 CR2 CR3 CRA CR4 N N 0nly Present on B Frame amp Up Drives 13 14 15 16 17 18 A1 A2 Contacts Shown in Unpowered State Y Y or Powered State with Fault Alarm Present Reserved for Terminal Signal Future Use TE True Earth Shield Termination 10 11 CR1 Programmable Contact 11 12 CR2 Programmable Contact 13 14 m le Contact Resistive Rating 115V AC 30V DC 5 0A 14 15 Programmable Contact Inductive Rating 115V AC 30V DC 2 0A 16 17 17 18 CR4 Programmable Contact 1 2 Reserved for Future Use 46 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Analog Inputs Outputs The 1336 PLUS II analog 1 0 configuration provides a standard set of inputs and outputs with the capability to install up to 2 option boards thus replacing the standard 1 0 with a variety of options connections are performed at TB2 Installing an option board in the slot A or B location will change the function of those terminals on TB2 from standard Only one option board can be installed in each slot The standard and optional 1 0 configurations a
85. 15 rpm providing a 120 1 constant torque speed range Improved acceleration control can provide up to 250 breakaway acceleration torque to move the toughest loads with ease e Solid out of the box performance Enhanced performance can be gained by programming the setup parameters with actual motor nameplate values Optimum results can be achieved by programming the actual amps required to generate no load flux and the actual voltage needed for IR compensation If these values are not known setup procedures can determine the exact values A fast accel mode is provided Disabling the Adaptive Current Limit feature provides the lowest possible acceleration time for low inertia applications A fast flux up mode is programmable to aid in acceleration with large motors e Selectable Volts Hertz modes are also available When selected they provide full functionality including Start Boost and Run Boost Boost Slope and Full Custom V Hz operation Process Pl Control Simple process control monitoring a feedback device and adjusting drive output according to feedback requirements can be accomplished with the 1336 PLUS II Proportional and integral gain adjustments plus feedback scaling error inversion output clamping and integrator reset functions allow the Process PI function to control the output of the 1336 PLUS II based on the PI reference setpoint and the feedback If the feedback device indicates that the process is moving aw
86. 152 6 00 0 WITH 0PTION BAY 1522 59 93 I All dimensions in millimeters and inches 9 WITHOUT OPTION BAY 916 36 06 7622 30 00 al 610 1336 24 00 1336 Puls DRIVE STD en DRIVE STD 457 18 00 305 12 00 152 0 09 6 00 0 152 305 457 610 762 914 0 152 305 457 610 76236 914 6 00 12 00 18 00 24 00 30 00 36 00 6 00 12 00 18 00 24 00 30 00 36 00 PREVI0US PAGE AUTO BYPASS LOGIC OVERLOAD RELAY MOTOR GROUND TERMINAL D BYPASS CIRCUIT BREAKER OR DISCONNECT SWITCH LINE GROUND TERMINAL BYPASS MOTOR FUSES SIGNAL GROUND TERMINAL 95 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Panel Layouts C Frame Drives 230V 15 22 kW 20 30 HP 460V 30 45 kW 40 60 HP 575V 18 5 45 kW 25 60 HP IP20 NEMA Type 1
87. 152 4 mm 152 4 mm 6 0 in 6 0 in e Allen Bradley 101 6 mm C 4 0 in Cc C 3 55006 Boone p Bion ARS 152 4 152 4 6 0 6 0 NOTE F Frame drives require 152 4 mm 6 0 in on the sides and or back for proper air flow Input Power Conditioning In general the 1336 PLUS II is suitable for direct connection to a correct voltage AC line that has a minimum impedance of 196 396 for 0 37 22 kW 0 5 30 HP drives relative to the rated drive input kVA If the line has a lower impedance a line reactor or isolation transformer must be added before the drive to increase line impedance If the line impedance is too low transient voltage spikes or interruptions can create excessive current spikes that will cause nuisance input fuse blowing overvoltage faults and may cause damage to the drive power structure The basic rules for determining if a line reactor or isolation transformer is required are as follows 1 If the AC input power system does not have a neutral or one phase referenced to ground see Unbalanced Distribution Systems on next page an isolation transformer with the neutral of the secondary grounded is highly recommended If the line to ground voltages on any phase can exceed 125 of the nominal line to line voltage an isolation transformer with the neutral of the secondary grounded is highly recommended 2 If t
88. 2 8 5 21 3 72 18 90 22 6 8 8 22 10 23 8 8 22 14 35 14 34 20 49 19 48 26 63 26 65 31 75 31 77 33 79 32 80 49 119 48 120 62 149 60 150 74 178 72 180 99 238 96 240 120 289 116 291 134 322 129 325 r VATES 1 1 12 14 1 7 2 2 28 1 8 2 3 28 3 5 24 3 0 3 8 4 8 3 2 4 0 5 7 7 2 48 6 0 8 5 107 72 9 0 13 157 12 3 15 4 18 6 22 4 175 22 20 4 245 19 1 24 23 28 22 27 23 28 22 2 29 35 27 34 36 43 33 42 41 49 38 48 50 61 47 59 52 63 52 65 62 75 61 77 62 75 61 77 77 93 76 96 99 119 96 120 124 149 120 150 148 178 143 180 148 178 143 180 198 238 191 240 241 290 233 292 268 322 259 325 297 357 287 360 297 357 287 360 350 421 339 425 350 421 339 425 392 471 378 475 392 471 378 475 433 521 418 525 438 527 424 532 486 585 470 590 438 527 424 532 552 664 534 670 552 664 534 670 Artisan Technology Group Quality Instrumentation Input Input Output Output kVA Amps Amps L 5 j 0 9 1 33 14 2 7 1 89 1 8 28 1 8 2 55 23 3 5 24 3 33 3 2 48 3 2 4 44 47 72 48 6 66 70 10 7 72 9 99 10 3 15 7 12 3 19 43 14 7 224 17 5 22 00 16 1 245 19 1 24 00 18 28 22 21 15 18 28 22 29 97 23 35 27 37 74 28 43 33 46 62 32 49 38 53 28 40 61 47 66 60 4 63 52 72 15 49 75 61 83 25 62 15 61 85 47 61 93 76 106 56 78 119 98 133 20 98 149 120 166 50 117 178 143 199 80 148 178 143 199 80 157 238 191 266 40 191 290 233 324 12 212 322 259 360 75 235 357 287 399 60 228 357 279 399 60 261 397 319 471 75 271 421 339 471 75 2
89. 2 9 244 1829 15 30 15 30 25 40 375 forvoltage drop 600 600 600 80 600 C 30 45 30 45 76 22 43 cable capacitance 182 9 82 9 82 9 762 82 9 X40 X60 40 60 25 40 375 and other issues 600 600 600 250 600 D 45 112 45 112 12 2 30 5 43 For retrofit 1829 1829 82 9 61 0 914 60 150 60 150 40 100 375 situations check 600 600 600 200 300 E 112 187 112 224 122 533 43 with the motor 1829 1829 82 9 1829 1829 150 250 150 300 40 75 375 manufacturerfor 600 600 600 600 600 F 87 336 187 336 183 533 43 insulation rating 1829 1829 82 9 1829 18729 250 450 250 450 60 75 375 600 600 600 600 600 G 87 448 187 448 183 533 43 1829 1829 82 3 1829 182 9 250 600 250 600 60 175 375 600 600 600 600 600 Type A Motor Characteristics phase paper or misplaced phase paper lower quality insulation systems corona inception voltages between 850 and 1000 volts Type B Motor Characteristics Properly placed phase paper medium quality insulation systems corona inception voltages between 1000 and 1200 volts 1329R L Motors These AC Variable Speed motors are Control Matched for use with Allen Bradley Drives Each motor is designed to meet or exceed the requirements of the Federal Energy Act of 1992 All 1329R L motors are optimized for variable speed operation and include premium inverter grade insulation systems which meet or exceed NEMA MG1 Part 31 40 4 2 51 Artisan Technology Group Quality Instrumentation Guaranteed 888 88
90. 2 Standard Analog Input 2 is maintained at this terminal configure with J11 10V or 20mA Pulse Output Pulse In Pulse In Analog 1 0 Option Slot A Analog 1 0 Option Slot 47 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Analog Inputs Outputs All isolated 1 0 is designed with full galvanic greater than 10 meg ohms less than 50 pf isolation This results in an insulation withstand capability of 200V AC from each channel to True Earth TE ground and between channels The Analog 1 0 Option Boards are summarized below Option Board Type Slot Description 1 Dual Analog Output B This option replaces both standard analog outputs with two single ended high resolution LA1C analog outputs Analog Output 0 is configurable to 0 10V or 0 20 mA operation while Analog Output 1 is for 0 20 mA operation only This option maintains access to the standard non isolated Analog Input 2 through TB2 6 Configuration remains with jumper J11 LA2 Dual Isolated Input This option replaces the two standard analog inputs with two galvanically isolated analog LA2C 2 inputs Both analog input channels are configurable for 0 10V or 0 20 mA operation LA3 Dual Isolated Output B Replaces Analog Input 2 and both standard analog outputs with two galvanically isolated LA3C high resolution analog outputs Both analog output channels
91. 207 0 185 2 275 0 15 35 7 5 130 0 76 2 85 3 6 71 8 50 11 42 8 15 7 29 10 83 0 60 0 30 5 12 3 00 3 36 14 8 M 260 0 350 0 212 0 230 0 320 0 15 35 15 35 130 0 133 0 86 0 15 90 10 24 13 78 8 35 9 06 12 60 0 60 0 60 5 12 5 23 3 39 85 0 1 Refer to the Derating Guidelines on Pages 56 60 for derating Information 22 Artisan Technology Group Quality Instrumentation 2 kW HP are constant torque ratings Guaranteed 888 88 SOURCE www artisantg com IP 20 NEMA Type 1 Dimensions Allen Bradley Frames B C D Mounting Holes 4 See Detail p Frames B amp C All Dimensions in Millimeters and Inches All Weights in Kilograms and Pounds Bottom View Will Vary with HP See Bottom View Dimensions Mounting Hole Detail Frames B amp C 7 0 28 7 1 0 28 12 7 0 50 EI 12 7 0 50 Mounting Hole Detail Frame D 10 4 0 41 Dia _ 147 0 58 1 pra 19 0 0 75 Dia Pre Installation Frame D Frame Shipping Reference Weight B1 B2 276 4 476 3 225 0 212 6 461 0 131 6 93 5 88 9 32
92. 27 1 20 75 711 2 28 00 19 1 Y 079 158 8 Y yyy 625 199 A 779 gt gt peo 108 0 4 25 x 158 8 6 25 Fan Horiz Removable Plate for 82 6 3 25 Cable Access 1 each side Conduit Access Area All Dimensions in Millimeters and Inches See page 2 1 for Mounting Information Approximate Shipping Weight drive amp pallet Bottom View 415 0 kg 915 lbs 25 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Open Dimensions Frame F Roll In Chassis All Dimensions in Millimeters and Inches 635 0 25 00 9 DANGER ES anen Bradiey 5 A awan L 2 x DANGER E 5 io 6 6 ells B o RLi 5 12 T L3 PE U M1 W M3 JO
93. 3 98 166 195 315 W37 W38 2 59 110 183 215 350 W38 W39 284 120 198 235 385 W39 W40 3 15 132 218 260 420 W40 W41 346 143 239 298 465 W41 W42 384 155 260 320 515 W42 W43 4 27 170 285 350 570 W43 W44 473 193 310 380 630 W44 W45 5 36 415 W45 W46 5 82 455 W46 W47 6 33 500 W46 W48 6 97 550 W48 W49 183 iu ix 1 49 W50 8 49 8 45 W50 W51 924 929 W51 W52 10 1 10 3 W52 W53 11 1 114 W53 W54 122 125 W54 W55 13 6 13 7 nee W55 W56 14 6 15 0 W56 W57 157 16 3 W57 W58 172 17 6 mE W58 W59 18 9 18 9 522 W59 W60 20 5 20 9 21 1 m W60 W61 22 2 22 9 23 7 25 1 W61 W62 243 250 257 27 5 W62 W63 a 27 6 285 30 5 W63 W64 30 0 30 5 33 5 W64 W65 32 0 33 0 36 5 m W65 W66 34 0 355 40 0 43 0 W66 W67 37 0 38 5 44 0 470 W67 W68 39 0 415 48 5 51 W68 w69 41 0 45 0 53 56 Weg W70 48 5 58 61 W70 W71 53 62 66 W71 W72 56 67 72 W72 W73 58 72 TI W73 W74 60 77 83 W74 WIS 62 82 89 W75 W76 me 88 95 W76 W77 94 102 W77 WIS 98 108 W78 W79 102 116 W79 W80 108 123 W80 W81 117 130 W81 W82 125 137 W82 W83 T 150 iis E das W83 W84 n ET aa 160 ess m W84 W85 PE bet s 165 d dus n W85 Table 181 1 Table 1951 Selection Guide Listed in the chart below are possible option combination conflicts that may occur when selecting 1336 PLUS II Packaged Drive Options Option Selection Rules
94. 4 0 5476 444 5 21 56 pne i 11 75 M Y d 380 635 0 635 0 A 15 00 25 00 25 00 1 69 3 50 Three Phase Ratings All Dimensions in Millimeters and Inches lt 101 6 4 00 9 g i P oll gt G x i 2286 0 90 00 e Y e a c 635 0 25 00 Option Mounting Location Mountable Option Codes From Previous Option List Page Plus BA BM CC D41 D42 DT FM Consult Factory Option Codes From Previous Option List Page Plus BC BD BP BS MP12A MP12N MP18A MP18N MQ2 MQ3 Removable Lifting Angle Vented Areas IP20 NEMA Type 1 Only Air Conditioner IP54 NEMA Type 12 Only Approximate Shipping Weights All Weights in Kilograms and Pounds Drive Drive Option and Bypass Option Enclosures Frame 460V CT 460V VT 575V A A2 IP 20 NEMA Type 1 IP54 NEMA Type 12 G 224 261 kW 224 261 kW 224 261 kW 2865 1 2560 3 264 2 139 7 1066 1247 300 350 HP 300 350 HP 300 350 HP 112 80 100 80 10 40 6 50 2350 2750 360 425 A 360 425 A 360 425 298 448 kW 298 448 kW 298 448 kW 2992 1 2687 3 327 7 215 9 1066 1275 400 600 HP 400 600 HP 400 600 HP 117 80 105 80 12 90 8 50 2350 2810 475 670 A 475 670 A 400 600 A 92 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artis
95. 4 20mA Option N5T Speed Trim proportional to the input pressure The 4 20mA signal is fed to the drive as either a speed command or speed trim Communication Options Single Point RIO 9 7 RIO communication options provide a single point remote 1 0 interface board The board can be Option GM1C GD1C or GMS1C configured for 1 4 1 2 3 4 or full rack with a baud rate of 57 6 115 or 230 kBaud The remote 1 0 Board may be set up by the user to control drive logic control speed reference commands monitor drive status and monitor drive logic RS232 422 485 DF1 or DH485 Protocol 6 7 Communication interface module Option GM2C GD2C or GMS2C DeviceNet 7 DeviceNet to scanport module Option GM5C GMS5C GM6C GMSEC or GU6C 1 The Bypass Operation capability provided by this option does not allow for maintenance of the drive or entry into the enclosure with power applied while operating in the bypass mode Bypass Options do not include the required 120V AC control power Control power may be supplied remotely by the user or as part of the drive package by ordering a Control Power option CF CP or CT see Options section 3 Where branch circuit protection is required in the drive option FM should be specified see Options section Requires a control power transformer option CP or CT 5 Contact Allen Bradley for possible drive enclosure size changes when selecting this option 6 GM Series Options are drive mounted
96. 5 250 35 250 325 187 325 187 B250 AN _ B250 AA B250 AE 9 3 3 325 250 360 300 325 187 360 224 250 AN BP250 AA79 3 3 BPR250 AN 7 BPR250A AE 7 89 325 250 360 300 325 187 360 224 250 AN 250 250 AE 8 9 3 3 360 300 425 350 360 224 425 261 B300 AN _ B300A AA B300A AE8 9 3 3 360 300 425 350 360 224 425 261 BP300 AN7 BP300 AA7 9 3 3 BPR300 AN 7 BPR300A AE 7 8 9 425 350 475 400 425 261 415 298 B350 AN _ B350A AA 50 8 9 3 3 425 350 475 400 425 261 415 298 BP350 AN7 BP350 AA7 9 3 3 BPR350 AN 7 BPR350A AE 7 8 9 475 400 525 450 415 298 525 336 B400 AN _ B400A AA B400A 8 9 3 3 475 400 532 450 415 298 532 336 BP400 AN7 BP400 7 9 3 3 BPR400 AN 7 BPR400A AE 7 8 9 525 450 590 500 525 336 590 373 B450 AN 450 9 B450A AE8 9 3 3 532 450 532 450 532 336 532 336 BP450 AN 7 450 3 3 BPR450 AN 7 BPR450A AE 7 8 9 590 500 670 600 590 373 670 448 500 AN B500A AA 500 8 9 3 3 670 600 670 600 670 448 670 448 B600 AN _ B600A AA B600A AE9 9 3 3 64 See page 65 for footnotes Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS II Selection Guide Constant Variable Torque Drives and Enclosures 500 600 Open NEM
97. 56 75 kW 75 100 HP Terminal Designations 380 480V 112 187 kW 150 250 HP Terminal Designations 500 600V 112 224 kW 150 300 HP Terminal Designations olo ele elelelelele 2 ff Heng Er TE DC DC PE PE ER BUS ais zi See Appendix B for detailed Dimensions To Motor Required 1 Input Fusing 1 User supplied 38 R L1 42 T43 U M V M2 W M3 INPUT OUTPUT E08 f I To Motor 1 Required Branch Circuit Disconnect AC Input Line Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Power Wiring TB1 rmm 380 480V 187 336 kW 250 450 HP Terminal Designations R L1 5 12 U M1 V M2 uv L3
98. 59 325 25 BP250C 212268 322 259 325 300 300 228 288 347 279 360 300 BX250V 228288 347 279 360 30 BP300C 235 297 357 287 360 300 250 235 297 357 287 360 35 350C 261 330 397 319 425 350 B3OOV 261 330 397 319 425 35 BP350C 277 350 421 339 425 350 wBP300V 277 350 421 339 425 400 400 294 371 446 359 475 400 350V 294 371 446 359 475 40 BP400C 310 392 471 378 475 400 BP350V 310 392 471 378 475 450 450 326 412 496 398 525 450 B40V 326 412 496 398 525 45 BP450C 347 438 527 424 532 450 BP400V 347 438 527 424 532 500 500 372 470 565 454 590 500 450 372 470 565 454 590 60 B600C 437 552 664 534 670 600 500 437 552 664 534 670 8 11 1 1 Drive ratings are at nominal values Refer to the Drive Derating Guidelines in the Standard Drives section 480V only Guaranteed 888 88 SOURCE www artisantg com 71 Drive Specifications Standard AC Line Fusing Drive input fuses are supplied as standard when required 1 The fuses provide branch circuit protection for the drive Generally fuses and fuse blocks are supplied F frame drives will have the fuses mounted internally to the drive itself If a Drive Disconnect Switch option is supplied the fuses will be resident on that switch except F frame drives Packaged drives may have different input fuse ratings than those recommended for equivalent standard 1336 PLUS II drives This is because packaged drives are rated for a single input voltage as oppose
99. 600 515 618 595 598 600 618 595 598 600 Control Inputs Option L4E L7E or L4 Contact Closure Interface Board Requirements Contacts must be capable of operating at 10mA current levels without signal degradation Reed type input devices are recommended The L4E L7E options are compatible with the following Allen Bradley PLC modules e 1771 0YL 1771 07L Note Option 14 is the same as Option but without encoder feedback terminals Option L5E L8E or L5 24V AC DC Interface Board Requirements Circuits used with Option L5 L8E must be capable of operating with high true logic DC external circuits in the low state must generate a voltage of no more than 8V DC Leakage current must be less than 1 5 mA into a 2 5k ohm load AC external circuits in the low state must generate a voltage of no more than 10V DC Leakage current must be less than 2 5 mA into a 2 5k ohm load Both AC and DC external circuits in the high state must generate a voltage of 20 to 26 volts and source a current of approximately 10 mA for each input The L5E L8E options are compatible with these Allen Bradley PLC modules e 1771 08 1771 0016 e 1771 0B16 e 1771 0BD 1771 0YL 1771 0BN e 1771 0ZL 1771 00 1771 0BB Note Option L5 is the same as Option L5E but without encoder feedback terminals Option LGE L9E or L6 115V AC Interface Board Requirements Circuits used with Option L6E LSE must be capable of operating with high true
100. 600V is used this wiring must be routed inside the drive enclosure and separated from any other wiring and or uninsulated live parts Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Terminal Block TB2 TB2 is located at the bottom of the Main Control Board 0 37 7 5 kW 0 5 10 HP A Frame drives have 18 positions Remaining frame sizes from 5 5 kW 7 5 HP and up have 22 positions The maximum and minimum wire size accepted by TB2 is 2 1 and 0 30 mm2 14 and 22 AWG Maximum torque for all terminals is 1 36 N m 12 Ib in Use Copper wire only Terminal Block TB3 The Control Interface Option provides a means of interfacing various signals and commands to the 1336 PLUS II by using contact closures Six different versions of the option are available 4 Contact Closure Interface1 e L4E L7E2 Contact Closure Interface1 with Encoder Feedback Inputs 5 24V AC DC Interface e 5E L8E2 24V AC DC Interface with Encoder Feedback Inputs e 6 115V AC Interface e L6E L9E2 115V AC Interface with Encoder Feedback Inputs The user inputs are connected to the option board through TB3 see Figure 2 1 for location The L4 L5 and L6 options each have nine control inputs The function of each input must be selected through programming as explained later in this section The L4E L7E L5E L8E and L6E L9E2 options are similar to L4 L5 and L6 with the addition of encod
101. 82 80 70 80 10 40 5 50 1375 1775 360 425 A 360 425 A 360 425 A 298 448 kW 298 448 kW 298 448 kW 2230 1 1925 3 327 7 215 9 624 832 400 600 HP 400 600 HP 400 600 HP 87 80 75 8 12 9 8 50 1375 1885 475 670 A 475 670 A 400 600 A 91 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Dimensions IP20 NEMA Type 1 and IP54 NEMA Type 12 Dimensions for G Frame Drives with Bypass lt A IP 54 NEMA 12 1 IP 54 NEMA Type 12 gt roc pum IP 20 NEMA Type 1 M gt 4 BIS DRIVE ENCLOSURE DRIVE OPTION BYPASS OPTION ENCLOSURE ENCLOSURE gt Allow lt gt Allow 1524 152 4 600 6 00 or e for Air Air Flow Flow E ha 762 0 5080 762 0 30 00 20 00 80 00 101 6 50 8 406421 i 508 2 00 16 00 1 26 00 Q00 y Z Z Z x D ale a 444 5 e Jazz 290 141016 438 074 1 406 4 1 4 00 660 4 50 8 17 17 00 hit 1600 26 00 Zi 2 00 BR VELL 25
102. 84 29 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation IP 20 NEMA Type 1 Bottom View Dimensions Frames D G All Dimensions in Millimeters and Inches 144 0 5 67 52 1 2 05 gt 34 9 50 0 1 38 1 97 Conduit Knockout 1 Plc Frame D 261 4 10 29 343 9 13 54 62 7 76 2 2 47 3 00 Conduit Knockout 2 Plcs 34 9 1 38 Conduit Knockout 3 Plcs 11 0 STA 5 080 204 5 f 805 WI 153 7 _ 605 11 Frame E lt 432 3 17 02 305 3 12 02 178 3 7 02 88 9 101 6 3 50 4 00 38 6 1 52 Conduit Knockout Pics 12 7 0 50 Conduit Knockout 6 Pics A 311 12 35 260 ah 10 25 525 8 25 ER B 4 Frame G 660 4 26 00 lt 508 200 1319 FT 29 0 1 14 E aro 1 Conduit 254 0 Access Area 10 00 lo JO Conduit Access Area Biss 11 75 N Y 381 0 429 15 00 15 9 0 63 Dia 2 Mtg Holes 1 69 Bottom 30 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Mounting Requirements
103. 9 Precharge Fault The precharge device was open 20ms after the end of a line loss condition or the bus charging alarm remains on for 20 seconds 22 DSP Reset Fault Power up has been attempted with an Open Stop contact or Closed Start contact 23 Loop Overrn Fault An overrun of the 2 5ms control loop has occurred 24 otor Mode Fault A fault has been detected originating from the Control Board 26 Power Mode Fault The internal power mode variable received an incorrect value 29 Hertz Err Fault This fault indicates that there is not a valid operating frequency 30 Hertz Sel Fault A frequency select parameter has been programmed with an out of range value 32 EEPROM Fault EEPROM is being programmed and will not write a new value 33 ax Retries Fault Drive unsuccessfully attempted to reset a fault and resume running for the programmed number of tries 34 Prm Access Flt A communication error occurred between the microprocessor and serial EEPROM or DSP 35 eg Slope Fault Drive software detected a portion of the v hz curve with a negative slope 36 Diag C Lim Fit The Cur Lim Trip En parameter was enabled 38 Phase U Fault A phase to ground fault has been detected between the drive and motor in this phase 39 Phase V Fault A phase to ground fault has been detected between the drive and motor in this phase 40 Phase W Fault A phase to ground fault has been detected between the drive and motor in this phase 41 UV Short Fault Excessive current has been detected between these two outpu
104. 94 446 359 527 25 310 471 378 527 25 326 496 398 582 75 347 527 424 532 05 372 565 454 654 90 347 527 424 532 00 437 664 534 743 70 437 664 534 743 70 Variable Torque Guaranteed 888 88 SOURCE www artisantg com Specifications Input Output Ratings continued Cat Input Input Output Output Input Input Output Output No Amps Amps Amps Amps rsen 500 600V Drives 600V Drives CWF10 21 225 24 2 1 2 0 2 5 24 2 1 2 0 CWF20 42 50 48 42 4 0 5 0 48 4 2 40 CWF30 62 375 72 6 2 6 0 75 72 6 2 6 0 CWF50 8 3 10 0 9 6 8 3 8 0 10 0 9 6 8 3 8 0 CWF75 9 11 10 10 10 11 10 10 10 CWF100 11 13 12 12 12 13 12 12 12 CWF150 17 20 19 19 19 20 19 19 19 CWF200 21 26 25 24 24 26 25 24 24 C025 27 32 31 30 30 32 31 30 30 C030 31 37 36 35 35 37 36 35 35 C040 38 45 44 45 45 45 44 45 45 C050 48 57 55 57 57 57 55 57 57 C060 52 62 60 62 62 62 60 62 62 C075 73 88 84 85 85 88 84 85 85 C100 94 112 108 109 109 112 108 109 109 C125 118442 137 137 138 142 137 137 138 C150 144 173 167 167 168 173 167 167 168 C200 217 261 251 251 252 261 251 251 252 C250 244 293 282 283 284 293 282 283 284 CX300 256 307 295 297 300 307 295 297 298 C300 258 309 297 299 300 309 297 299 300 C350 301 361 347 349 350 361 347 349 350 CP CPR350 301 361 347 343 350 361 347 349 350 C400 343 412 397 398 400 412 397 398 400 400 343 412 397 398 400 412 397 398 400 C450 386 464 446 448 450 464 446 448 450 C500 429 515 496 498 500 515 496 498 500 C
105. A Type 1 NEMA Type 4 NEMA Type 12 Drive Rating IP00 IP20 IP65 IP54 Amps kW CT HP VT HP No Enclosure General Purpose Resist Water Dust Industrial Use 20 0 75 1 1 CWF10 CWF10 CWF10 AF CWF10 AJ 40 15 2 2 CWF20 AN CWF20 AA CWF20 AF CWF20 AJ 6 0 22 3 3 CWF30 AN CWF30 AA CWF30 AF CWF30 AJ 8 0 37 5 5 CWF50 AN CWF50 AA CWF50 AF CWF50 AJ 10 55 75 75 CWF75 CWF75 AA CWF75 AF CWF75 AJ 12 75 10 10 CWF100 AN CWF100 AA CWF100 AF CWF100 AJ 19 11 15 15 CWF150 AN CWF150 AA CWF150 AF CWF150 AJ 24 15 20 20 CWF200 AN CWF200 AA CWF200 AF CWF200 AJ 30 18 5 25 25 C025 A C025 AA C025 AF C025 AJ 35 22 30 30 C030 A C030 AA C030 AF C030 AJ 45 30 40 40 C040 A C040 AA C040 AF C040 AJ 57 37 50 50 C050 A C050 AA C050 AF C050 AJ 62 45 60 60 C060 AN C060 AA 060 AF C060 85 56 75 75 C075 A C075 AA 3 3 109 75 100 100 C100 A C100 AA 3 3 138 93 125 125 C125 A C125 AA 3 3 158 112 150 150 C150 A C150 AA9 3 3 252 149 200 200 C200 A C200 3 3 284 187 250 250 C250 A C250 AA9 3 3 300 224 300 300 CX300 AN CX300 AAI 3 3 350 261 350 350 CP350 AN 7 CP350 AA 7 9 3 3 CPR350 AN 7 3 3 400 298 400 400 CP400 AN 7 CP400 AA 7 9 3 3 CPR400 AN 7 3 3 300 224 300 300 C300 AN C300A AAS 3
106. AA B250C AJ F 250 325 0 BP250C AA BP250C AJ 300 360 0 BP300C AA BP300C AJ 350 425 0 BP350C AA BP350C AJ 400 475 0 400 BP400C AJ 450 527 0 BP450C AA G 300 360 0 B300C AA B300C AJ 350 425 0 B350C AA B350C AJ 400 475 0 400 B400C AJ 450 525 0 B450C AA B450C AJ 500 590 0 B500C AA B500C AJ 600 670 0 600 B600C AJ 1 The basic drive does not include a Control Power Transformer If local 115V AC power is not available refer to options CF CP and CT 2 The drive rating is based on a nominal voltage of 240 volts and a carrier frequency of 4kHz at altitudes of 1 000 meters or less Refer to the Drive Derating Guidelines in the Standard Drives section 3 The drive rating is based on a nominal voltage of 480 volts and a carrier frequency of 4kHz at altitudes of 1 000 meters or less Refer to the Drive Derating Guidelines in the Standard Drives section 107 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Selection Guide 460V Variable Torque Drives and Enclosures 1 2 4 NEMA Type 1 IP20 NEMA 4 IP65 NEMA Type 12 IP54 Drive Rating General Purpose Resists Water and Dust Industrial Use Dust Ti Nominal HP Code Code Code Al 1 2 12 BF05V AA BFO05V AF BF05V AJ 3 4 17 BFO7V AA BFO7V AF BFO7V AJ 1 23 BF10V AA BF10V AF BF10V AJ 11 2 3 0 BF15V AA BF15V AF BF15V AJ A2 2 4
107. ATED A DEFAULT PROCESS DEFAULT ANLG IN O LO 0 0 DEFAULT FLT CLEAR MODE ENABLED DEFAULT PROCESS DEFAULT ANLG IN O HI 100 DEFAULT LINE LOSS FAULT DISABLED DEFAULT PROCESS DEFAULT ANLG IN 1 LO 0 DEFAULT MOTOR TYPE INDUCTION DEFAULT PROCESS DEFAULT ANLG IN 1 HI 100 DEFAULT SLIP F L A 1 0 HZ DEFAULT 4 20 LOSS SEL MIN ALARM DEFAULT INPUT MODE STATUS 3 WRE DWELL FREQUENCY 0 0 HZ DEFAULT MAXIMUM SPEED 400 HZ DEFAULT TB3 TERM 22 SEL REV FOR DEFAULT DWELL TIME 0 SECS DEFAULT ENCODER TYPE QUADRATURE DEFAULT TB3 TERM 23 SEL JOG DEFAULT PWM FREQUENCY 4 KHZ DEFAULT ANLG OUT O OFFSET DISABLED DEFAULT TB3 TERM 24 SEL AUX FAULT DEFAULT ENCODER PPR 1024 PPR DEFAULT FLYING START EN DISABLED DEFAULT TB3 TERM 26 SEL SPEED SEL 3 DEFAULT LANGUAGE START BOOST ENGLISH 0 MTS DEFAULT DEFAULT FSTART FORWARD FSTART REVERSE 60 HZ 0 HZ DEFAULT DEFAULT TB3 TERM TB3 TERM 27 SEL 28 SEL SPEED SEL 2 SPEED SEL 1 DEFAULT DEFAULT BREAK FREQUENCY 25 MAX FREQ DEFAULT OUT SEL AT SPEED DEFAULT ANLG IN 2 LO 0 DEFAULT BREAK VOLTAGE 25 RATED V DEFAULT DIG OUT FREQ 0 0 HZ DEFAULT ANLG IN 2 100 DEFAULT STOP SELECT 2 COA
108. C350 9 350 Figure AB amp AC 1000 5935 6935 CP CPR350 350 Figure Z 580 6125 6705 C400 9 400 Figure AB amp AC 1430 7120 8550 CP CPR400 400 Figure AA 711 7000 7711 450 9 450 Figure AB amp 1465 8020 9485 C500 9 500 Figure AB amp AC 1500 8925 10425 C600 9 600 Figure AB amp AC 1610 10767 12377 Derate Heat Dissipation Cat No Amps Curve 2 3 Drive Watts 2 3 4 Heatsink Watts 2 Total Watts 2 200 240V DRIVES Pre Installation parenthesis in table indicates Series C drive ratings Base Derate Amps are based on nominal voltage 240 480 or 600V If input voltage exceeds Drive Rating Drive Output must be derated Refer to Figure AE Rating is at 4 kHz 2 kHz for 224 448 kW 300 600 HP 500 600V If Carrier frequencies above 4 kHz are selected drive rating must be derated Refer to Figure A AC 3 Drive Ambient Temperature Rating is 40 C If ambient exceeds 40 C the drive must be derated Refer to Figure A AC Drive Rating is based on altitudes of 1 000 m 3 000 ft or less If installed at higher altitude drive must be derated Refer to Figure AD 5 Important Two 2 725 fans are required if an open type drive is mounted in a user supplied enclosure 8 Important 1336F BPRxxx drives require two 2 fans capable of producing greater than 450 CFM if an open type drive is mounted in a user supplied enclosure 55 Artisan Technology Group Quality Instrume
109. CF200C AF CF200C AJ C 25 30 0 C025C AA C025C AF C025C AJ 30 35 0 C030C AA C030C AF C030C AJ 40 45 0 C040C AA 040 C040C AJ 50 57 0 050 050 C050C AJ 60 62 0 060 060 C060C AJ D 75 85 0 075 C075C AJ 100 109 C100C AA C100C AJ 125 138 C125C AA C125C AJ E 150 168 C150C AA C150C AJ 200 252 C200C AA C200C AJ 250 284 C250C AA C250C AJ 300 300 CX300C AA CX300C AJ G 300 300 C300C AA C300C AJ 350 350 C350C AA C350C AJ 400 400 C400C AA C400C AJ 450 450 C450C AA C450C AJ 500 500 C500C AA C500C AJ 600 600 C600C AA C600C AJ 1 The basic drive does not include a Control Power Transformer If local 115V AC power is not available refer to options CF CP and CT 2 The drive rating is based on a nominal voltage of 480 volts and a carrier frequency of 4kHz at altitudes of 1 000 meters or less Refer to the Drive Derating Guidelines in the Standard Drives section 3 The drive rating is based on a nominal voltage of 600 volts and a carrier frequency of at altitudes of 1 000 meters or less Refer to the Drive Derating Guidelines in the Standard Drives section When choosing horsepower related options for variable torque drives match the option to the actual variable torque horsepower rating not to the base catalog number Example A 15 HP VT Drive requires a 15 HP Circuit Breaker not a 10 HP Circuit Breaker Artisan Technology Group Quality Instrumentation
110. DC external circuits in the low state must generate a voltage of no more than 8V DC Option L8EC With Encoder Feedback Leakage current must be less than 1 5 mA into a 2 5k ohm load AC external circuits in the low state must generate a voltage of no more than 10V AC Leakage current must be less than 2 5 mA into 2 5k ohm load Both AC and DC external circuits in the high state must generate a voltage of 20 to 26 volts and source a current of approximately 10 mA for each input The L5C L8EC option is compatible with the following Allen Bradley PLC modules e 1771 0B 1771 0BN 1771 0016 e 1771 07L 1771 0B16 1771 0BD 1771 00 e 1771 0YL e 1771 0BB 115V AC Control Interface Circuits used with the standard L6 interface or Option L9EC must be capable of operating with high true logic Standard L6 Interface Without Encoder Feedback In the low state circuits must generate a voltage of no more than 30V AC Leakage current must be less than Option LSEC With Encoder Feedback 10 mA into a 6 5k ohm load In the high state circuits must generate a voltage of 90 115V AC 10 and source a current of approximately 20 mA for each input The L6C L9EC option is compatible with the following Allen Bradley PLC modules e 1771 0W e 1771 0WN e 1771 0A e 1771 OAD Contact Factory for Recommended Series Rev Level 1 Rack size will impact enclosure size Contact Allen Bradley for possible enclosure size changes 2 Actual hardware
111. Drive Circuit Circuit 5 Catalog Dual Element Non Time Breaker Protector 5 Number Input Ouput Time Delay Fuse Delay Fuse 3 4 140M Motor Starter with Adjustable Current Range X 1336 Amps Amps Min Max Min Max Amps Amps Available Catalog Numbers A4 10 1 24 20 3 3 3 6 15 3 140M C2E B25 F20 2 48 40 6 6 6 10 15 7 140M C2E C63 140M D8E C63 F30 3 72 6 0 10 12 10 15 5 7 140M C2E C10 140M D8E C10 140 10 F50 5 9 6 8 0 15 20 15 20 20 15 140M C2E C10 140M D8E C10 140M F8E C10 F75 75 100 10 0 15 20 15 30 35 15 140M C2E C10 140M D8E C10 140M F8E C10 F100 10 120 120 20 25 20 40 40 15 140M C2E C16 140M D8E C16 140M F8E C16 F150 15 190 190 25 35 25 60 60 30 140M C2E C20 140M D8E C20 140M F8E C20 140 CMN 2500 F200 20 250 240 30 45 30 80 80 30 140M C2E C25 140M D8E C25 140M F8E C25 140 CMN 2500 C 025 25 310 300 40 60 40 100 100 50 140M F8E C32 140 CMN 4000 030 30 360 350 50 70 50 125 125 50 140M F8E C45 140 CMN 4000 040 40 440 450 60 90 60 150 150 70 140M F8E C45 140 CMN 6300 050 50 550 570 80 110 80 200 200 70 140M CMN 6300 060 60 60 0 620 90 125 90 225 225 100 140M CMN 6300 D 075 75 840 850 110 150 110 300 300 100 140M CMN 9000 100 100 1080 109 0 150 200 150 350 350 150 125 125 137 0 1380 175 250 175 500 350 250 E 150 150 167 0 168 0 225 300 225 500
112. Hz P Jump 80 0 01 Hz 0 00 25 Maximum Freq 0 00 Hz Bus Regulation 288 Settings Selection Parameter Disabled Load Loss Det 290 Settings Selection Parameter Disabled Load Loss Level 291 1 0 100 0 Load Loss Time 292 1Second 0 30 Sec 0 Sec Bus Reg Level 358 716 895 Volts ax Bus Volts 325 1 Volt 403 907 1009 Volts 358 716 895 Volts nput Mode 241 Mode Selection Parameter Status B3 Term 22 242 Settings Selection Parameter Rev For Input 3 B3 Term 23 243 Settings Selection Parameter Jog Input 4 TB3 Term 24 244 Settings Selection Parameter Aux Fault Input 5 TB3 Term 26 245 Settings Selection Parameter Spd Sel 3 Input 6 B3 Term 27 246 Settings Selection Parameter Spd Sel 2 Input 7 TB3 Term 28 24 Settings Selection Parameter Spd Sel 1 Input 8 nput Status 55 Settings Selection Parameter Out Select 158 Settings Selection Parameter At Speed CR2 Out Select 174 Settings Selection Parameter Running CR3 Out Select 175 Settings Selection Parameter Fault Out Select 176 Settings Selection Parameter Alarm Dig Out Freq 159 0 01 Hz 0 00 Hz Maximum Freq 0 00 Hz Dig Out Current 160 0 0 200 0 Dig Out Torque 161 0 0 0 200 of Rated Amps 0 0A Dig At Temp 267 186 0 255 C 0 Error 293 0 01 Hz 400 00 Hz None Pulse Out Select 280 Settings Selection Parameter Output Freq Pulse Out Scale 281 Factor 1 4096 1024 PPR Pulse In Scale 264 Factor 1 4096 1024 PPR At Time 327 0 01 Sec 0 0
113. Input 10 and One Isolated Configurable Input LA7 Analog Interface Port B Choose One All Drives Single ended Non isolated Input Configurable or Pot amp 2 Single ended Non isolated 0 20mA Outputs LA1 Two Isolated Configurable Outputs LA3 One Isolated Configurable Input amp Output LA4 One Isolated Pulse Input amp Non isolated Output and One Single ended Non isolated 0 10V Output LA5 Human Interface Module Snap In IP20 00 Open A G Frame amp IP20 NEMA Type 1 NEMA Type 1 A D Frame Drives Snap In Cradle Blank Plate HASB Programmer Only HASP Programmer Only amp Upload Download Capability HCSP Programmer Controller with Analog Pot HAS1 Programmer Controller with Analog Pot amp Upload Download Capability HCS1 Programmer Controller with Digital Pot HAS2 Programmer Controller with Digital Pot amp Upload Download Capability HCS2 Human Interface Module IP20 NEMA Type 1 IP20 NEMA Type 1 Programmer Only E G Frame Enclosures HAP2 Programmer Controller with Analog Pot HA12 Programmer Controller with Digital Pot HA22 Human Interface Module 66 IP66 or IP54 Programmer Display Only NEMA Type 12 Drives HJP Programmer Controller with Digital Pot HJ2 1 This option may be used on an IP65 or IP66 rated enclosure to meet watertight indoor applications 2 Requires a Communication Option Cable 1202 Cxx to be functional A maximum of one Communication Option may b
114. NAMEPLATE FOR DATA MOTOR FLA MUST NOT EXCEED DRIVE AMP RATING GENERAL NOTES 4 COIL AND CONTACT CROSS REFERENCING NUMBERS ADJACENT TO COIL AND UNDER CONTACT INDICATE SHEET AND LINE NUMBERS BUILDING GROUND TO BE GROUNDED BY CUSTOMER SIGNAL COMMON amp 0O4 1 3 INDICATES LINE NO 3 INDICATES SHEET NO 1 POWER EQUIPMENT GROUND 248 CHASSIS CONNECTION M UNDERSCORED TEXT LINE INDICATES NORMALLY CLOSED CONTACT 2 INDICATES COMPONENTS SUPPLIED BY OTHERS OFF PAGE CROSS REFERENCING NUMBERS ADJACENT TO SOURCE 3 INDICATES TB4 TERMINAL BLOCK Ai FROM 1 24 4 9g INDICATE SHEET AND LINE NUMBERS 24 4 INDICATES LINE 24 INDICATES TERMINAL INDIVIDUAL INDICATES SHEET NO 1 1000 71dNYS 9 COMPONENTS TO 1 24 N N N N N N N N 2 gt zs S 8 85515 BR BS N B o ilo 2 o S BN 0 0 G N The Drive and Power Distribution page of the drawings contains the 1336 PLUS II drive the heart and brains of the system and all the power related components The power distribution scheme is determined by the catalog number options chosen Any Human Interface Modules or drive mounted options located within the drive package will also be shown on this page Motor data will be shown if supplied with the order or if an Allen Bradley motor is ordered 112 Artisan Technology Group Quality Instrumentation G
115. No Display Name Fault Description 02 Auxiliary Fault The auxiliary input interlock is open 03 Power Loss Fault DC bus voltage remained below 85 of nominal for longer than 500ms 04 Undervolt Fault DC Bus voltage fell below the minimum value 05 Overvolt Fault DC bus voltage exceeded maximum value 06 otor Stall Fault Current remained over 15096 of Rated Amps for more than 4 seconds 07 Overload Fault Internal electronic overload trip 08 Overtemp Fault Heatsink temperature exceeds a predefined value of 90 C 195 F 09 Open Pot Fault An external pot is connected and the common side of the pot is open 0 Serial Fault A SCANport adapter has been disconnected and the Logic Mask bit for that adapter is set to 1 1 Op Error Fault A SCANport device requests a Read or Write of data type not supported 2 Overcurrent Flt Overcurrent is detected in instantaneous overcurrent trip circuit 3 Ground Fault A current path to earth ground in excess of 100A has been detected at one or more of the drive output terminals 4 Option Error An analog option board has been installed in the wrong slot 5 otor Thermistor An analog option board with thermistor input is installed and the value at the terminals is less than 60 ohms or greater than 3300 ohms 6 Bipolar Dir Fit 3 Wire Bipolar input is the active frequency reference and direction control is not possible 2 Wire Run Forward or Run Reverse commands attempt direction control but bipolar input is not masked from direction control
116. PL Q Q Q Q Option D13 Hand Off Auto start stop speed ref SS Option D12 Option D14 Option D16 Option D18 Option D10 Ws a ed an s E amp Auto Mes Hand Auto Hand Auto Auto Manual Start Jog Start pt on U uto anua Spee reterence on y D Option D16 D15 Option plus Auto PL amp Manual PL 9 9 9 2 Auto 9 9 Option D17 Start PB amp Stop PB Aio Manual Manual sip Manual Sop Option D18 Start PB Stop PB amp Auto Manual SS Option D19 Start PB Stop PB amp Jog PB 0ption Set D2 0ption Set D3 Option Set D4 N Option D21 Option 022 Option 031 Option 032 Standard with Any Option D41 Option Set D2 Cu CORE RR Manual Bypass Option Drie Bypass Option D21 Control Power On PL Run PL amp Drive Fault PL Option D22 2 D21 Options plus Motor Fault PL Drive Motor Drive At Drive Oft Fault Fault Fault Speed Fwd Rev Bypass Opti on Set D3 ei Option D31 At Speed PL Standard with Standard with Standard with Any Option D42 Option D32 Forward Reverse SS Option MH and MH2 Option EH Auto Bypass Option Bypass Enabled Mode Motor Enclosure AB Option Set D4 E Option 041 3 Drive Mode PL amp Bypass Mode PL 0 Option D42 4 Auto Bypass Enabled On PL amp Bypass Mode PL Option Set D5 Option Set D6 Option Set D5 Drive Disable push pull MHPB
117. PLANATION TERMINAL WIRE RANGE 2223 TB4 15 22 14 Ga 2204 TB4 14 AUTO RUN CONTACT FAULT NO FAULT NC FAULT NO FAULT NC 18 16 Ga 18 16 Ga 18 16 Ga 18 16 Ga CR6 6 10 CR6 10 2 18 16 Ga 18 16 Go 18 16 18 16 CR11 5 9 CR11 9 1 CR11 6 10 CR11 10 2 PWR ON NO PWR ON NC PWR ON NO PWR ON NC 18 16 Ga 18 16 Ga 18 16 Ga 18 16 Ga ALARM NO ALARM NC ALARM NO ALARM NC CR10 5 9 CR10 9 1 CR10 6 10 CR10 10 2 18 16 Go 18 16 Go 18 16 Ga 18 16 Go GENERAL WIRING NOTES SIGNAL 1 CUSTOMER TERMINALS ARE SIZED FOR 75 C WIRE PER NEC TABLE 310 16 75 C 2 STEEL CONDUIT IS RECOMMENDED FOR ALL WIRING CLASSES BUT IS REQUIRED FOR SIGNAL CATEGORY CLASSES ALUMINUM CONDUIT REQUIRES THE SAME MINIMUM SPACING AS SHOWN FOR CABLE TRAYS 3 SPACES BETWEEN CLASSES SHOWN IN THE INSTRUCTION MANUAL IS THE MINIMUM REQUIRED FOR PARALLEL RUNS EQUAL TO OR LESS THAN 400 FEET GREATER SPACING SHOULD BE USED WHERE POSSIBLE 4 No 16 Ga WIRE IS THE MINIMUM RECOMMENDED SIZE FOR CONTROL WIRE POWER WIRE IS SELECTED BY CONTINUOUS MAXIMUM LOAD FLA SHIELDS FOR SHIELDED SIGNAL CABLE MUST BE CONNECTED AT ONE END ONLY THE OTHER END SHOULD BE CUT BACK AND INSULATED IT IS RECOMMENDED THAT SHIELDS FOR SHIELDED CABLE FROM A CABINET TO AN EXTERNAL DEVICE BE CONNECTED AT THE CABINET END OF THE CABLES SHIELDS FOR SHIELDED POWER CABLE MOTOR LEADS MUST BE CONNECTED AT BOTH ENDS THE
118. PREVIOUS PAGE OVERLOAD RELAY BYPASS CIRCUIT BREAKER OR DISCONNECT SWITCH BYPASS MOTOR FUSES WITHOUT OPTION BAY TERMINAL BLOCK DRIVE 1336 PLUS II STD 1524 3048 6 00 12 00 D AUTO BYPASS LOGIC MOTOR GROUND TERMINAL LINE GROUND TERMINAL SIGNAL GROUND TERMINAL 4572 18 00 609 6 762 889 24 00 30 00 35 00 99 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Panel Layouts F Frame Drives 460V 187 336 kW 250 450 HP 575V 261 298 kW 350 400 HP IP20 or IP54 NEMA Type 1 or NEMA Type 12 Consult Allen Bradley when adding additional heat producing components to existing IP 54 NEMA Type 12 rated drives F FRAME 2 BAY WITHOUT BYPASS F FRAME 3 BAY WITH BYPASS 2286 2286 90 00 90 00 2133 6 2133 6 84 00 84 00 1981 2 1981 2
119. Pounds Drive Drive Option and Bypass Option Enclosures 460V CT 460V VT A 2 IP 20 NEMA Type 1 IP54 NEMA Type 12 F 187 224 kW 224 kW NOT APPLICABLE 139 7 1066 1066 250 300 HP 300 HP NO AIR CONDITIONER 5 50 2350 2350 325 360 A 360 A REQUIRED 261 336 kW 261 336 kW 261 298 kW 2419 4 2267 0 235 0 21590 1066 1247 350 450 HP 350 450 HP 350 400 HP 95 25 89 25 9 25 8 50 2350 2750 425 525 A 425 525 425 475 90 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Dimensions IP20 NEMA Type 1 and IP54 NEMA Type 12 Dimensions for G Frame Drives without Bypass gt Allow 1524 6 00 for Air Flow 1 IP 54 NEMA Type 12 A IP 54 NEMA Type 12 1270 0 IP 20 NEMA Type 1 50 00 M gt AO 9 lt DRIVE ENCLOSURE DRIVE OPTION gt Allow lt ENCLOSURE 1524 6 00 for Air X Flow 762 0 508 0 30 00 20 00 406 4 50 8 2n 4 __ 8 200 7115000 y ii x x 2 4445 e 17 50 431 8 29 0 17 00 7 144 547 6 444 5 21
120. Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options Standard Door Layout Standard Door Layout Elapsed Drive Enclosure Time Option Enclosure Meter D3 Interface O Option 102 D6 Option Set D1 D5 OO Option Set D4 Door Mounted Operator Devices Operator devices specified in the drive catalog number are supplied mounted and wired on the enclosure door The Standard Door Layouts shown indicate the mounting locations of door mounted options or option groups The operator device options listed below are logically grouped into sets Only one option code selection may be made from each set Where possible Allen Bradley Bulletin 800E style operator devices will be supplied Description Code PB Pushbutton SS Selector Switch PL Pilot Light POT Potentiometer MHPB Mushroom Head Pushbutton Legend plates will be 30 mm x 50 mm black with white lettering Option Set D1 Option Set D1 Option D11 Option D13 Option D15 Option D17 Option D19 Orion 0 Start PB Stop PB PB amp Auto Manual SS Start Jog Start h Option D11 Hand Off Auto start stop only SS amp Auto Manual speed reference only SS Wu e Ed bride Stop Stop Option D12 D11 Options plus Hand PL amp Auto
121. ST DEFAULT DIG_OUT CURRENT 0 DEFAULT ANLG SIGNAL LOSS 0000000 DEFAULT S CURVE TIME 0 0 SECS DEFAULT DIG OUT TORQUE 0 0 AMPS DEFAULT LINE LOSS MODE LOBUS gt OFF DEFAULT S CURVE ENABLE DISABLED DEFAULT SPEED KP 0 DEFAULT PULSE IN SCALE 64 DEFAULT PRESET FREQ 4 0 0 HZ DEFAULT SPEED KI 1 00 DEFAULT DSP COMM FAULT ENABLED DEFAULT PRESET FREQ 5 0 0 HZ DEFAULT BOOST SLOPE 1 5 DEFAULT DIG AT TEMP 120 DEGC DEFAULT PRESET FREQ 6 0 0 HZ DEFAULT CR2 OUT SELECT RUNNING DEFAULT MOTOR THERM FLT ENABLED DEFAULT PRESET FREQ 7 0 0 HZ DEFAULT CR3 OUT SELECT FAULT DEFAULT ALARM MASK 2 111111111111111 DEFAULT SPEED CONTROL SLIP DEFAULT CR4 OUT SELECT ALARM DEFAULT ANLG OUT 1 SEL CURRENT DEFAULT TRAVERSE PERIOD 0 00 SECS DEFAULT MOTOR NP RPM 1750 RPM DEFAULT ANLG OUT 1 LO 0 0 DEFAULT MAX TRAVERSE 0 00 HZ DEFAULT MOTOR NP HERTZ 60 HZ DEFAULT ANLG OUT 1 HI 100 0 DEFAULT P JUMP 0 00 HZ DEFAULT PROCESS 2 PAR 54 DEFAULT ANLG OUT 1 ABS ENABLED DEFAULT BLWN FUSE FLT ENABLED DEFAULT PROCESS 2 SCALE 1 00 DEFAULT ANLG OUT 1 OFFST DISABLED DEFAULT CUR LIM TRIP EN DISABLED DEFAULT PROCESS 2 TXT 1 DEFAULT PULSE OUT SELECT
122. TIONAL 2 OPTIONAL 2 OPTIONAL 2 1 A Language Module must be specified with each drive 2 At least one of either a Control Interface Human Interface or Communication Card Option will be required to make the drive functional The chosen option s may be ordered factory installed or as add on kits 63 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS Selection Guide q 200 240V Drive Rating Open NEMA Type 1 NEMA Type 4 NEMA Type 12 Constant Torque IP00 IP20 IP65 IP54 Amps kW CT HP VT HP 2 No Enclosure General Purpose Resist Water Dust Industrial Use 23 0 37 0 5 A0F05 AN AQF05 AA A0F05 AF A0F05 AJ 3 0 0 56 0 75 A0F07 AN AQF07 AA AQFO7 AF AQFO7 AJ 45 0 75 1 AQF10 AN AQF10 AA AQF10 AF AQF10 AJ 6 0 2 1 5 15 AQF15 AN AQF15 AA AQF15 AF AQF15 AJ 8 0 1 5 2 2 AQF20 AN AQF20 AA AQF20 AF AQF20 AJ 12 22 3 3 AQF30 AN AQF30 AA AQF30 AF AQF30 AJ 8 40 5 5 AQF50 AN AQF50 AA AQF50 AF AQF50 AJ 22 55 75 75 AQF75 AN AQF75 AA AQF75 AF AQF75 AJ 22 55 75 75 007 007 007 A007 AJ 34 75 10 10 A010 AN A010 AA A010 AF A010 AJ 48 11 15 15 A015 AN A015 AA A015 AF A015 AJ 65 5 20 20 A020 AN A020 AA A020 AF A020 AJ 7 8 5 25 25 A025 AN A025 AA A025
123. Type 1 and IP54 NEMA Type 12 For D E Frame Drives IP54 NEMA Type 12 gt lt A2 IP54 NEMA Type 12 101 6 lt gt Al IP20 NEMA Type 1 gt 4 00 m mm q 7 lt gt gt 20 00 Y 650 15 00 C2 A O O A g a 9 e Z 1 i i lt e Allen Bradley Ey gagag d 4 Allow a a o o 1524 6 00 i for gt 9 e e 2286 0 M 9 Nr 90 00 Flow Option Mounting Location DRIVE OPTION EXPANDED OPTION Ee ENCLOSURE ENCLOSURE M DRIVE OPTION All Option Codes Not ENCLOSURE Listed Below EXPANDED 0ption Codes BA BM OPTION CC D41 D42 DT ENCLOSURE and JS CONSULT Option Codes BC BD FACTORY BP BS CM JL LQ d LR LT LW 12 g sj i MP12N MP18A MP18N 02 and MQ3 Q Removable Lifting Angle Air Conditioner 54 NEMA Type 12 Only O Vented Areas IP20 NEMA Type 1 Only Heatsink Fan Accessible from Inside of Enclosure lt 2540 gt 10 00 NC d JAAN AA DAD DAN AD IT DAN AA e e 50 8 1 em 2174 CONDUIT ACCESS CONDUIT ACCESS iA EY z 8 56 Ili 293 6 eid 11 56 e 12194 CONDUIT ACCESS CONDUIT ACCESS 11 00 I I 820 1 beg qp eee See a
124. a a 3 20 di L Dt T l l l A 5 87 0 625 Dia Mounting Holes 4 7 Y I i i ika 50 8 D3 x 4064 508 300 4501 300 2 00 16 00 2 00 14 7 02 772 7 7 0440 Three Phase Ratings All Dimensions in Millimeters and Inches Approximate Shipping Weights All Weights in Kilograms and Pounds Drive Option Enclosure Only Drive Option amp Expanded Option Enclosures 1 20 IP 54 IP 20 54 NEMA 1 NEMA 12 NEMA 1 NEMA 12 Frame 230V 460V CT 460V VT 575V A Al A2 ci 02 D D1 30 45 KW 45 112 56 112KW 56 93kW 6350 11430 1378 0 15304 6071 4661 85 1 3175 1280 5766 5334 386 436 522 D 40 60 60 150HP 75 150HP 75 125HP 25 00 45 00 5425 6025 25 75 2021 6 21 12 50 6 90 2270 21 00 850 960 1150 120 1804 85 180 96 180 85 138 A 56 93KW 112 187 kW 149 187KW 112 149KW 889 0 1397 0 16320 17844 6541 5133 1323 4445 1753 8306 7874 408 458 544 E 75 125HP 150 250 HP 200 250 HP 150 300HP 35 00 55 00 6425 70 25 0575 2021 521 17 50 6 90 32 70 31 00 900 1010 1200 240 325 A 199 325 A 240 325 A 158 300 A 88 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Dimensions IP20 NEMA Type 1 and IP54 NEMA Type 12 Dimensions for F Frame Drives without Bypass
125. ackaged Drive Catalog Number This chart should be used to understand the scope of the overall product offering and assembling a specific catalog number Care should be taken to verify that the assembled catalog number qualifies as an available configuration option combination by referring to all pages of this section 105 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Selection Guide HORSEPOWER CODE CTHP VTHP DUTY VOLTAGE A 230VAC F05 F07 SVS SSS SS ann BONS r3 gt an eye 075 00 125 0 5 07 1 15 2 3 5 Jm 10 15 20 25 30 40 50 60 75 100 125 Constant NEMA Torque Type 1 AF NEMA 4 AJ NEMA Type 12 ENCLOSURE B 460VAC F05 P400 450 P45 500 600 0 5 0 75 0 5 0 75 100 128 150 200 250 250 300 300 350 350 400 400 450 450 500 600 Constant NEMA Torque Type 1 V Variable Torque AF NEMA Type 4 AJ NEMA Type 12 C 575VAC F0 F20 F30 F50 75 F100 F150 F200 025 030 040 050 060 075 100 125 150 200 250 300 X300 350 400 450 500 600 106 100 125 150 200 250 300 300 350 400 450 500 600 Constant NEMA Torque 1 AF NEMA Type 4 AJ NEMA Type 12 CODE DESCRIPTION A208 BC BD BM BP BS CB AUG CF
126. al electrical codes may determine additional requirements for these installations Installations Per U S NEC UL CSA Fuses In general the specified fuses are sutiable for branch short circuit protection and provide excellent short circuit protection for the drive The fuses offer a high interrupting capacity and are fast acting Refer to the North American selections in the table on page 37 Circuit Breakers The Westinghouse HMCP breakers specified in the table on pages 34 35 also provide branch short circuit protection Because circuit breakers are typically slower than fuses and those listed are magnetic trip only they may not be as effective in offering short circuit protection to the drive in the event of an internal drive short circuit They may not be as effective in limiting damage to the drive IEC Installations Fuses For those installations that are not required to meet the U S NEC UL CSA the specified fuses are sutiable for branch short circuit protection and provide excellent short circuit protection for the drive The fuses offer a high interrupting capacity and are fast acting Refer to the European selections in the table on page 37 Circuit Breakers For those installations that are not required to meet the U S NEC UL CSA requirements additional devices are available as input circuit breakers The Bulletin 140 and KTA3 devices meet the circuit breaker requirements of IEC947 2 but do not meet UL CSA circuit breaker req
127. ality Is consistent Removable lifting bar on cost usiomer Aesthetically ergonomically large drives Interface wiring pleasing Faster troubleshooting Control Power Power Bypass Mode Enclosure Drive Input Door Mounted Drive Circuit Transformer Line Ground Distribution Smart Motor Exhaust Fans Fuses Operator Devices Breaker with Fusing Terminal Terminal Block Controller SMC 7 Bypass _ L Contactor E Drive Auxiliary Control Relay Logic Drive Output Drive Input Motor Thermal SMC Output Terminal Block Contactor Contactor Overload Relay N Contactor Motor Ground Terminal 500 HP 6 Pulse 460V AC NEMA Type 1 Floor Mounted Packaged Drive with SMC Style Bypass 119 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Integrated Architecture Superior s Value Added Complete Services amp Global Automation Expertise Supply amp Local Capabilities World Class Products The 1336 PLUS II is a world class product that will help to provide you with a single solution for virtually all of your speed control requirements Its common design and control interface functions will help save you time and money in set up integration and maintenance of your automation system For Allen Bradley Drives support there are specialists at local sales offices and distributor locations across North America and around the world We also offer G
128. anteed 888 88 SOURCE www artisantg com Pre Installation Power Wiring TB1 Input and output power connections are performed through terminal block TB1 For maintenance and setup procedures the drive may be operated without a motor connected The most common causes are e Wiring AC line to drive output or control terminals Improper bypass or output circuits not approved by Allen Bradley Output circuits which do not connect directly to the motor Contact Allen Bradley for assistance with application or wiring ATTENTION An incorrectly applied or installed bypass system can result in component damage or reduction in product life TB1 SIGNALS Terminal Description PE Ll Potential Earth Ground TE L Shield Termination True Earth L1 S L2 T L3 AC Line Input Terminals DC DC DC Bus Terminals U T1 V T2 W T3 Motor Connection Terminal Max Min Wire Size 1 Maximum Torque Block Type AWG N m Ib in A1 A4 Page 50 5 3 0 8 10 18 1 81 16 1 50 8 4 0 8 8 18 1 81 16 2 50 13 3 0 5 6 20 1 70 15 C Page 50 26 7 0 8 3 18 5 65 50 D Page 513 127 0 2 1 250 14 6 00 52 674 24 00 14 2 6 00 52 E Page 51 3 253 0 2 1 500 MCM 14 10 00 87 F Page 52 3 303 6 2 1 600 MCM 14 23 00 200 G Page 52 3 303 6 2 1 600 MCM 14 23 00 200 1 Wire sizes given are maximum minimum si
129. antg com Panel Layouts The panel layouts shown on the following pages are typical for the drive ratings listed he layouts include a worst case Pre Engineered P Options Only scenario See Option List on the next page The dimension grid can be used to determine available panel space by taking into account which of the components shown will actually be included in an individual drive package A1 A3 Frame Drives 230 460V 0 37 3 7 kW 0 5 5 HP IP20 NEMA Type 1 WITH OPTION BAY 1000 39 37 914 36 00 762 dimensions in millimeters and inches 30 00 610 WITHOUT OPTION BAY 24 00 457 18 00 1336 PLUS II DRIVE STD 1336 PLUS DRIVE STD 305 12 00 o o 152 6 00 TERMINAL TERMINAL BLOCK STD BLOCK STD 0 152 305 457 600 0 152 305 457 600 6 00 12 00 18 00 23 62 6 00 12 00 18 00 23 62 IP54 NEMA Type 12 IP65 NEMA Type 4 Consult Allen Bradley when adding additional heat producing components to existing NEMA Type 4 or 12 rated drives
130. are configurable for 0 10V or 0 20 mA operation LA4 Isolated Input B This option replaces Analog Input 2 and both standard analog outputs with a galvanically LA4C 2 Isolated Output isolated analog input and a galvanically isolated high resolution analog output Both analog channels are configurable for 0 10V or 0 20 mA operation 5 Analog Output Pulse B This option replaces Analog Input 2 and both standard analog outputs with a single ended LABC Output Pulse Input high resolution analog output a single ended 5V pulse output and galvanically isolated pulse input The analog output channel is configurable for 0 10V or 0 20 mA operation LA6 Isolated Bipolar This option replaces the two standard analog inputs with agalvanically isolated analog LA6C 2 Isolated Thermistor input and a galvanically isolated thermistor input Analog Input 0 is configurable Input for 10V or 20 mA operation with polarity determining forward or reverse operation Analog Input 0 is suitable for use with PTC sensor chains with a maximum total resistance at normal operating temperature of 1 8k ohms An indication occurs in short circuit or over temperature conditions A short circuit condition is when the total resistance of the sensor chain is less than 60 ohms with reset from the short circuit condition occurring when the resistance exceeds 70 ohms An over temperature condition is when the total resistance of the sensor chain exceeds 3 3k ohms w
131. ask will generate a Bipolar Direction F16 fault Packaged Drives Program options which are typical of North America Other locations should contact their local Rockwell Automation office for availability of similar poroduct 48 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Standard Analog 1 0 Setup The 1336 PLUS rr has a series of jumpers to connect the standard 1 0 to TB2 when no analog options LA1 LA2 etc are present Connectors J9 and J10 see below each have four jumpers connecting pins 1 2 3 4 5 6 and 7 8 These jumpers must be in place for the inputs and outputs to be active at TB2 Connector J9 Input Configuration J8 J11 J13 0 10V OP 3 J13 TB2 3 Input 1 o mM Pot Configuration Shown TB2 4 8 O 27 Common 0 20 mA TB2 3 e O O Input 1 TB2 2 40 3 Input 0 TB2 1 2 O 1 Pot Ref 5V 0 10V Ome TB2 5 Common g J8 TB2 2 Input 0 7 O 7 0 10 Configuration Shown 0 20 mA 0 10V TB2 9 8 7 Common O O OO 3 411 TB2 6 Input 2 TB2 8 6 9 Ojo Output 1 0 20 mA Configuration Shown TB2 7 4 Output 0 0 20 mA TB2 6 20 O Input 2 Connector J10 In addition each input can be configured see figure above for 0 10V 0 20 mA or potentiometer Placing a jumper across the top of the connect
132. ation is possible for A amp B Frame drives at a derating of 5096 refer to frame designations on Page 22 and the Derating Guidelines on Pages 56 60 Displacement Power Factor A1 A3 Frame 0 80 Standard 0 95 with Optional Inductor 4 Frame amp Up 0 95 Standard Efficiency 97 596 at rated amps nominal line volts Maximum Short Circuit Current Rating 200 000A rms symmetrical 600 volts when used with AC line fuses specified on Page 37 Control Specifications Method Sine coded PWM with programmable carrier frequency Ratings apply to all drives A Frame 2 10 kHz Drive Rating based on 4 kHz B Frame 2 8kHz Drive Rating based on 4 kHz C amp D Frame 2 6kHz Drive Rating based on 4 kHz E Frame amp Up 2 6kHz Drive Rating based on 2 kHz refer to frame designations on Page 22 and the Derating Guidelines on Pages 56 60 Output Voltage Range 0 to rated voltage Output Frequency Range 0 to 400 Hz Frequency Accuracy Digital Input Within 0 01 of set output frequency Analog Input Within 0 496 of maximum output frequency Selectable Motor Control sieges vecroe COntrol with full tuning Standard V Hz with full custom capability Accel Decel Two independently programmable accel and decel times Each time may be programmed from 0 to 3600 seconds in 0 1 second increments Intermittent Overload Constant Torque 150 of rated output for 1 minute Variable Torque 115 of rated output for 1 minute
133. ay from the desired setpoint the software responds by adjusting the drive output until the feedback again equals the setpoint Selectable inputs provide auto manual capability for open loop threading operation Programmable presets and preloads assure smooth transitions PI Reference Select Integral Term 0 pi reference PI Reference Speed Adder Config sqrt fdbk Config inv error Parameter 65 PI Output Freq Command Master Frequency Reference 32767 Compute Speed Accel Speed He Speed Command Control Ramp er PI Config zero clamp Output Frequency Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Function Description Encoder Feedback For those applications that require excellent speed regulation the 1336 PLUS II offers optional encoder feedback This option er 40 1 provides closed loop speed regulation from no load to full load 9 Slip Comp 405 of 0 1 A feedback encoder and interface board L4E L5E or L6E with encoder inputs is required The encoder loss detection feature of the 1336 PLUS II requires the use of L7E L8E or L9E 43 Typical 1 1 1 1 1 1 1 l l l 0 10 20 30 40 50 60 70 80 90 100 of Load Slip Compensation To develop torque in an induction motor rotor speed slips relative to stator s
134. ber Definition 105 Thermal Overload Relay Data 109 Heater Element 110 Option Selection Rules 111 30 HP NEMA TYPE 1 Packaged Drive with Option Enclosure DRAWING SAMPLES 112 69 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Product Description The 1336 PLUS Standard Packaged Drive Package The heart of every standard packaged drive is a 1336 PLUS II variable frequency controller The packaged drives program provides 1336 PLUS II drives assembled with a much larger offering of factory mounted options than what is normally available with a standard product Ratings are provides for 0 37 93 kW 0 5 125 HP at 230V 0 37 448 kW 0 5 600 HP at 460V or 0 75 448 kW 1 600 HP at 575V Separate constant torque and variable torque ratings are available for 460V applications Packaging Removable common Human Interface Module Provides simplicity of programming and flexibility of operation Thermal dissipation management Design and extensive infra red testing minimizes hot spots to maximize reliability Modular enclosure Design to accommodate a wide variety of drive ratings and option combinations IP 20 IP65 amp 54 NEMA Type 1 4 amp 12 configurations Accommodated with heat sink through
135. ce 62 Settings Read Only Use Last Freq Command 65 0 01 40000 one Drive Direction 69 Settings Read Only one Stop Mode Used 26 Settings Read Only Coast otor Mode 141 Settings Read Only one Power Mode 142 Settings Read Only one Output Pulses 67 1 Pulse 0 65535 one Current Angle 72 Deg Read Only Heatsink Temp 70 P G 0 255 Set Defaults 64 Settings Selection Parameter Ready DC Bus Memory 212 Volt Read Only one eas Volts 272 Volt Read Only one EEPROM Cksum 172 None Read Only one Rated Volts 47 Volt Read Only Drive Rating Rated Amps 10 Read Only Drive Rating Rated kW n kW Read Only Drive Rating Firmware Ver 7 None Read Only 0 00 Cntrl Board Rev 251 None Read Only 0 00 Rated CT Amps 148 0 1A Read Only Drive Rating Rated CT kW 49 kW Read Only Drive Rating Rated VT Amps 98 0 1A Read Only Drive Rating Rated VT kW 199 kW Read Only Drive Rating Drive Type 6 Read Only Drive Rating Direction Mask 94 Bit 1 0 0 01 Start Mask 95 Bit 1 0 0 0 Jog Mask 96 Bit 1 0 0 011 1 Reference Mask 97 Bit 1 0 0 011 Accel Mask 98 Bit 1 0 0 0 Decel Mask 99 Bit 1 0 0 011 Fault Mask 100 Bit 1 0 0 011 OP Mask 101 Bit 1 0 0 0 raverse Mask 305 Bit 1 0 0 011 Sync Mask 308 Bit 1 0 0 011 Logic Mask 92 Bit 1 0 0 0 Local Mask 93 Bit 1 0 0 011 Alarm Mask 1 206 Bit 1 0 0 01 Alarm Mask 2 271 Bit 1 0 0 0 Stop Owner 102 Bit 1 0 Read Only None Direction Owner 103 Bit 1 0 Read Only None Start Owner 104 Bit 1 0 Read Only None
136. com 4 rtisan Artisan Technology Group is your source for quality Femoog Ge new and certified used pre owned equipment FAST SHIPPING AND SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT DELIVERY Experienced engineers and technicians on staff Sell your excess underutilized and idle used equipment TENS OF THOUSANDS OF at our full service in house repair center We also offer credit for buy backs and trade ins IN STOCK ITEMS www artisantg com WeBuyEquipment EQUIPMENT DEMOS HUNDREDS OF InstraV ea REMOTE INSPECTION LOOKING FOR MORE INFORMATION MANUFACTURERS Remotely inspect equipment before purchasing with Visit us on the web at www artisantg com 7 for more our interactive website at www instraview com 7 information on price quotations drivers technical LEASING MONTHLY specifications manuals and documentation RENTALS ITAR CERTIFIED Contact us 888 88 SOURCE sales artisantg com www artisantg com
137. cycling the Start contact Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Digital 1 0 Default Settings TB3 Pre Installation Available Functions for Inputs 3 through 8 A variety of combinations made up of the following inputs are available Input Description 1st 2nd Accel Closing these inputs 1st or 2nd Accel 1st or 2nd Decel commands the corresponding 1st 2nd Decel rate If both inputs are open or both are closed the current rate is maintained 1st 2nd Accel Decel Allows selection of the accel or decel time used by the drive 1 2nd 0 15 Auxiliary Faults the drive via external devices i e motor thermoswitch O L relays etc Opening this contact will fault F02 Aux Fault the drive and shut the output off ignoring the programmed stop mode Clear Fault If drive has faulted closing this input will clear the fault Digital Pot MOP These inputs increase up or decrease down the drive commanded frequency when MOP Motor Operated Up Down Potentiometer is chosen as the frequency command source The rate of increase decrease is programmable Forward Closing these inputs Forward or Reverse commands the corresponding direction If both inputs are open or both are closed the current direction is maintained Forward Reverse Available only with three wire control Closing this input commands reverse direction and opening this input com
138. d The buffer stores faults in a first in Next Fault D 4th Fault first out manner Additional diagnostic parameters listed in the Diagnostic Group Refer to the Parameter List on Page 18 3rd Fault Buffer 1 2nd Fault Buffer 2 1st Fault Buffer 3 17 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Parameter List The 1336 PLUS II uses an extensive set of parameters divided into groups for ease of programming Grouping replaces a sequentially numerical parameter list with functional parameter groups that increase operator efficiency and help reduce programming time Group Param No Disp Units Values Default Output Current 54 0 1A 0 200 Rtd Drv Out Current one Output Voltage 1 1 Volt 0 200 Rtd Drv Out Volts one Output Power 23 2009 Rtd Out Power Bus Voltage 53 1 Volt 0 200 DC Bus Volt Max one Output Freq 66 0 01 Hertz 400 00 Hz one Freq Command 65 0 01 Hertz 400 00 Hz one Anlg In 0 Freq 138 0 01 Hertz 0 00 400 00 Hz one Anlg In 1 Freq 139 0 01 Hertz 0 00 400 00 Hz one Anlg In 2 Freq 140 0 01 Hertz 0 00 400 00 Hz one Encoder Freq 63 0 01 Hertz 0 00 400 00 Hz one Pulse Freq 254 0 01 Hertz 0 00 400 00 Hz one Freq 137 0 01 Hertz 0 00 400 00 Hz one Heatsink Temp 70
139. d to the voltage range of a standard product Drive Rating and Catalog Number 230V AC 230 AC 460V AC CT 460V AC CT 460V AC VT 460V AC VT 575V AC 575V AC Fuse Quantity Vendor HP Cat No HP Cat No HP Cat No HP Cat No Description Required Part Number 0 5 0 75 BFOSC BFO7C 0 5 0 75 BF05V BFO7V 1 CF10C 3A 3 Bussmann LPJ 3 0 5 0 75 5 7 1 1 5 BF10C BF15C 1 1 5 BF10V BF15V 2 CF20C 6A 3 Bussmann LPJ 6 1 AF10C 2 BF20C 2 BF20V 3 CF30C 10A 3 Bussmann LPJ 10 1 5 2 AFI5C AF20C 3 BF30C 3 BF30V 5 7 5 CFS0C CF75C 15A 3 Bussmann LPJ 15 5 7 5 14 50 BF75C 5 10 17 5 BF50V BF75V 10 CF100C 20A 3 Bussmann LPJ 20 3 AF30C 15 CF150C 25A 3 Bussmann LPJ 25 10 17 54 BF100C 15 25 BF100V 20 200 30 3 Bussmann LPJ 30 15 BF150C 24A BF200C 20 BF200V 35A 3 Bussmann LPJ 35 5 AF50C 40A 3 Bussmann LPJ 40 15 B015C 35A 3 Bussmann JKS 35 75 A007C 25 C025C 40A 3 Bussmann JKS 40 20 B020C 25 020 45A 3 Bussmann JKS 45 10 A010C 30 030 50 3 Bussmann JKS 50 25 B025C 40 C040C 60A 3 Bussmann JKS 60 15 A015C 30 B030C 30 B030V 70A 3 Bussmann JKS 70 40 040 40 50 BX040V B040V 50 050 80 3 Bussmann JKS 80 60 C060C 90A 3 Bu
140. defined through programming For Packaged Drives functions are pre programmed at the factory for a specific application and configuration and should not require field re programming A variety of combinations made up of the following inputs are available Control Interface Options e Start 2 Accel Decel Rates 2 Stop Mode Selects 15V 24V TTL e Stop Clear Fault 3 Speed Selects e Run Forward AC DC Contact Reverse Enable Run Reverse Std L5C LAC e Digital Potentiometer MOP Auxiliary Local Control With Encod Feedback 49 48EC EC routinely disconnects then reapplies line power to the drive for the purpose of starting and stopping the motor ATTENTION The drive is intended to be controlled by control input signals that will start and stop the motor A device that is not recommended If this type of circuit is used a maximum of 3 stops in any 5 minute period with a minimum 1 minute rest between each cycle is required These 5 minute periods must be separated by 10 minute rest cycles to allow the drive precharge resistors to cool Refer to codes and standards applicable to your particular system for specific requirements and additional information ATTENTION User remote speed reference signals are terminated to logic common at TB2 terminals 3 amp 4 This puts the negative or common side of these signals at earth ground potential Control schemes should be examined for p
141. des 1203 SFC amp 1202 10 Cables SCANport Expander Module All Drives One to Two 203 SG2 One to Four 203 SG4 Flex 1 0 SCANport Module 4 All Drives Flex 1 0 Terminal Base 336 FB1 Flex 1 0 Module 336 FM1 HIM Snap In IP20 NEMA Type 1 00 Open A G Frame amp IP20 Snap In Cradle Blank Plate NEMA Type 1 A D Frame 201 HASB Programmer Only Drives 201 HASP Programmer Only amp Upload Download Capability 201 HCSP Programmer Controller with Analog Pot 201 HAS1 Programmer Controller with Analog Pot amp Upload Download Capability 201 HCS1 Programmer Controller with Digital Pot 201 HAS2 Programmer Controller with Digital Pot amp Upload Download Capability 201 HCS2 HIM Hand Held 1 20 NEMA Type 1 1 20 NEMA Type 1 E G Frame Requires Cable Below Enclosures Programmer Only 201 HAP Programmer Controller w Analog Speed Pot 201 HA1 Programmer Controller w Digital Speed Pot 201 HA2 HIM IP66 NEMA Type 12 UL Type 4X Indoor IP66 NEMA Type Programmer Only 12 UL Type 4X 1201 HJP2 Programmer Controller w Digital Speed Pot Indoor Enclosures 201 HJ22 Option Cable Kit Connect to Comm Port All HIMs not mounted 0 33 Meters 1 1 Feet on the drive chassis 202 C03 1 Meter 3 3 Feet 202 C10 3 Meter 9 8 Feet 202 C30 9 Meter 29 5 Feet 202 C90 Door Mount Bezel Kit 20 NEMA Type 1 User Supplied IP20 201 DMA NEMA Type 1 Enclosures and HIM 1 This option may be used on an IP65 or IP66 rated enclosure to meet watertight indoor applicati
142. e R 100 1336 400 400 ee of Drive 80 Rated Amps 79 60 50 2 4 Carrier Frequency in kHz Figure S Howe 1336F BP450 BP450 aa of Drive 80 Rated Amps 700 _ 60 50 x 1 2 4 Carrier Frequency in kHz Figure T 1336 500 600 of Drive 90 Sohe Assumes two 2 725 CFM cooling fans for Rated Amps 70 50 Hz IP 20 NEMA Type 1 enclosure 60 Hz 60 50 Hz 50 7 1 1 2 i 4 Carrier Frequency in kHz Figure U T 1336F CWF10 through CWF200 Wm of Drive 96 Not Rated Amps 94 Recommended 92 90 7 I 1 I 4 6 8 10 12 Carrier Frequency in kHz Figure V 95 1336 150 site of Drive 85 Rated Amps 80 75 70 65 1 2 4 Carrier Frequency kHz Figure W Mone 90 1336F C200 ii of Drive Rated Amps Kia 60 50 40 Artisan Technology Group Quality Instrumentation 4 Carrier Frequency in kHz Pre Installation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Derating Guidelines mamam Standard Rating for Enclosed Drive in 40 C Ambient amp Open Drive in 50 C Ambient mamma Derating Factor for Enclosed Drive in Ambient between 41 C amp 50 C Figure X 1336F C250 of Drive Rated Amps Figure Y 1336F CX300 of Drive Rated Amps Figure Z 100 1336F CP350 CPR350 90 80 of Drive Rated Amps 70 60 50 2 4
143. e Variable Torque Input nput Output Output Input Input Output Output Cat No kVA Amps kVA Amps 0 5 BFOSC 0 9 1 3 0 9 11 0 5 BF05V 0 9 1 1 14 1 12 075 BFO7C 1 3 1 6 2 13 16 075 BFON 14 17 21 14 17 1 BF10C 1 6 2 2 8 16 2 1 1 BF10V 1 8 2 2 2 8 18 23 15 BF15C 22 26 33 22 28 15 BF15V 23 28 35 24 3 2 BF20C 3 0 3 7 46 3 38 2 BF20V 32 3 8 48 32 4 3 BF30C 42 51 64 42 53 3 BF30V 47 57 7 2 48 6 5 F50C 6 6 8 0 67 84 BF50V 7 0 8 5 10 7 12 9 75 B007C 8 11 13 10 175 75 BX007V 8 11 13 10 125 75 75 9 5 11 6 45 112 14 75 BF75V 122 147 185 13 9 175 10 B010C 11 14 17 13 16 1 10 B007V 9 12 14 11 14 10 F100C 122 447 185 139 175 10 BF100V 171 207 26 19 9 25 15 B015C 16 21 25 19 242 15 010 14 18 22 17 21 20 B020C 21 26 32 25 31 20 B015V 18 23 28 22 27 25 B025C 26 33 40 3 39 25 B020V 23 28 35 27 34 30 B030C 30 38 46 36 45 30 B030V 32 41 49 38 48 40 BX040C 40 50 61 47 59 40 BX040V 40 50 61 47 59 50 050C 48 60 73 60 75 50 B040V 41 52 63 52 65 60 BXOGOC 62 75 6 7 60 BX060V 62 75 61 77 60 060C 54 68 82 68 85 75 B075C 69 87 105 84 106 75 060 61 77 93 76 96 100 100 90 114 137 110 138 100 075 78 99 119 96 120 125 125 113 143 172 138 173 125 B100V 98 124 149 120 150 150 150 148 178 143 180 150 125 117 148 178 143 180 15 B150C 130 164 197 159 199 200 200 172 217 261 210 263 200 150 157 198 238 181 240 25 B250C 212 268 322 259 325 250 200 191 241 290 233 292 250 B250V 212 268 322 2
144. e capacitors are permanently connected and not switched the general rules for impedance mismatch above apply 3 If the AC line frequently experiences transient power interruptions or significant voltage spikes an isolation transformer or 5 reactors are recommended Line reactors and isolation transformers can be ordered as loose items or installed in the drive enclosure 85 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Dimensions IP20 NEMA Type 1 Dimensions For A C Frame Drives 375 4 127 lt A gt 14 78 950 Loc 125 335 0 Al 0 49 203 0 13 19 132 0 Y lt 2 gt 19 p 7 99 gt lt 5 20 gt A 4 6 i Mounting Holes 2 Lifting Holes 2 A see detail Frames M B amp C Only q Ex B2 SA mm EXPANDED OPTION EXPANDED OPTION ENCLOSURE ENCLOSURE ES TA l F A 7 DRIVE OPTION 2 2 ENCLOSURE Additional Mounting Holes Not Present When EXPANDED OPTION ENCLOSURE Is Required e Allen Bradley 4 ee 22 2 IO saang ao c posa 2 d 53 amp 1 9 amp Mounting Slots 2 nn Y Y see detail O a
145. e connection must be made at both ends to minimize interference If cable trays or large conduits are to be used to distribute the motor leads for multiple drives shielded cable is recommended to reduce or capture the noise from the motor leads and minimize cross coupling of noise between the leads of different drives The shield should be connected to the ground connections at both the motor and drive end Armored cable also provides effective shielding Ideally it should be grounded only at the drive PE and motor frame Some armored cable has a PVC coating over the armor to prevent incidental contact with grounded structure If due to the type of connector the armor is grounded at the cabinet entrance shielded cable should be used within the cabinet if power leads will be run close to control signals In some hazardous environments it is not permissible to ground both ends of the cable armor because of the possibility of high current circulating at the input frequency if the ground loop is cut by a strong magnetic field This only applies in the proximity of powerful electrical machines In such cases consult factory for specific guidelines Conduit If metal conduit is preferred for cable distribution the following guidelines must be followed Drives are normally mounted in cabinets and ground connections are made at a common ground point in the cabinet Normal installation of conduit provides grounded connections to both the motor frame
146. e ordered factory installed on A Frame drives 2 for B Frame drives and up limited to 1 Snap in and 1 Main Control Board mount Each Flex 1 0 SCANport Module requires 1 1203 FB1 and 1 1203 FM1 5 The encoder loss detection feature of the 1336 PLUS Il requires the use of L7E L8E or L9E Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS II Selection Guide Field Installed Options Used Catalog No Description With Loose Kit Remote Mounted w Integral 115V AC Power Supply All Drives Single Point RIO 203 GD12 RS 232 422 485 DF1 DH485 203 6022 Remote Mounted for use with 24V DC Power Supply All Drives Single Point RIO 203 GK12 RS232 422 485 DF1 DH485 203 GK22 DeviceNet 203 GK5 2 Enhanced DeviceNe 203 GU6 2 Drive Mounted and Drive Powered A Frame Drives with loose snap in cradle blank plate Adapter 1 w Snap in Single Point RIO Cradle Blank Plate 336 GM13 RS232 422 485 DF1 DH485 Protocol Frame amp Up 336 GM23 DeviceNet Adapter 6 or Adapter 1 336 GM53 Enhanced DeviceNe w Snap in Cradle Blank Plate 336 GM6 3 5 Firmware Download Module All Drives 336F FDM Module allows firmware upgrade Control NetM to SCANport Adapter All Drives 203 135 Remote Mounted DIN Rail 24V DC Requires 24V DC power supply Smart Serial to SCANport Adapter All Drives 203 555 Inclu
147. e running With the Line Loss Fault parameter enabled if input power is lost T1 the drive will continue to operate until the bus voltage falls below 8596 of nominal T2 At this point the drive output is turned off and a 500 mS timer is started One of the following conditions will then occur 1 The bus voltage will fall below minimum before the time expires T6 This will generate an Undervoltage Fault 2 The bus voltage will remain below 8596 but above minimum and the timer expires T5 This will generate a Line Loss Fault 3 The input power is restored T3 and the bus voltage rises above the 8596 level before the timer expires T4 This allows the drive to turn its output on and resume running 100 85 Vgus Minimum Vgus DIAGRAM 2 100 85 Vgus Minimum Vgus Function Description ndervoltage Fault 1 depends on Low Bus Fault 1 1 T n 15 1 Loss of Power T2 Bus Level at 85 of Nominal Outputs Shut Off T3 Power Returned 4 Outputs Turned On T5 Minimum Bus Voltage Level Undervoltage Fault Point Off Output Line Loss Fault 7 ndervoltage Fault depends on Low Bus Fault 1 1 1 T3 4 T6 5 1 Loss of Power T2 Bus Level at 85 of Nominal Outputs Shut Off T3 Power Returned 4 Outputs Turned On T5 500mS Time Out Line Loss Fault T6 Minimum Bus Voltage Level Undervoltage Fault Point 1 1 2 Line
148. eNe Enhanced DeviceNe Single Point RIO RS232 422 485 DFI DeviceNe Enhanced DeviceNe HIM Blank NEMA Type 1 Programmer NEMA Type 1 Analog NEMA Type 1 Digital NEMA Type 1 Programmer NEMA Type 12 Digital NEMA Type 1 Blank Open Programmer Open Analog Open igital Open Control Power s Fault a D ardware amp acts Alarm cts Run ounting I 22 232 co LC Hardware amp Mounting Contacts At Speed Contactor Drive Input Contactor Drive Output Two Analog Outputs One Input Two Analog Inputs Two Analog Outputs One Analog Input and Output Two Analog Outputs One Input Two Analog Inputs Two Analog Inpu Control Interface TTL a NOTE Not all options are available with all ratings CODE DESCRIPTION 450 460 EC LTEC L8EC 49 10 LR alll AW MB ME MP18A Control Interface 24V Control Interface 115V AC Std Control Int TTL Encoder Control Int TTL Encoder Control Int 24V Encoder Control Int 115V Encoder Output Reactor NEMA 1 Input Reactor NEMA 1 Input Reactor NEMA 4 12 Output Reactor NEMA 4 12 Blower Motor Starter Motor Time Run Meter Motor Heater Control Remote Power Motor Heater Control Local Power hermal Overload Class 20 2 Pulse Front End with Auto Transformer 2 Pulse Front End with Isolation Transfor
149. eed The drive will then bring the motor to the commanded speed Flying start can be accomplished with or without a motor mounted encoder The 1336 PLUS II can be programmed to perform seven logic steps with or without the use of a programmable controller These steps can be based on Time Digital Input Time and Digital Input Encoder Feedback Counts or Pulse Input Counts The Step Logic is selected as a continuous loop or fault End Fault Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Power Loss Ride Thru DIAGRAM 1 The 1336 PLUS II has the ability to ride through short power interruptions loss of input power to the drive the drive offers two methods of operation With the Line Loss Fault parameter disabled if a power interruption occurs T1 the drive will continue to operate off stored DC bus energy until bus voltage drops to 85 of its nominal value 2 At this point the drive output is shut off allowing the DC bus to discharge more slowly he drive will retain its logic and operating status as long as bus voltage is above the absolute minimum bus voltage refer to Page 7 If bus voltage should fall below this level T5 the drive will trip and Undervolt Fault will be displayed If input power is restored before this minimum is reached 3 and bus voltage rises above the 85 level the drive will restore output power to the motor and resum
150. el parameter shown _ limited to 70 of drive rating until a a Sta rt command is issued Stop Command Time Opening Enable Input instead or of reissuing a Start Command will cause drive to Stop b the Enable input is opened Reset Run The 1336 PLUS II offers the ability to automatically reset a fault if the condition that causes the fault is no longer present and restart Both the number of reset attempts 0 9 and the time between reset attempts 0 30 Sec are programmable If the condition causing the fault is still present when the number of reset run tries is exceeded the drive will shut down and issue a Max Retries Exceeded Fault This feature will not operate for ground faults or shorted output faults The 1336 PLUS II displays which of the available adapters currently ON Gon Gon fon mim Go owns certain control functions To avoid conflict some owners are exclusive only one device can issue a direction command while gt Adapter 1 currently others can have multiple control many devices can simultaneously Typical Owner Direction Command controlling direction issue a start command Owner displays are excellent diagnostic tools displaying precisely where drive control commands are coming from All external control connections to the 1336 PLUS II are made through a multi connection communication bus called SCANport Frame drives have 5 availab
151. equency programmed divided by 32767 15 bits 60 Hz 0 0018 Hz 100 Hz 0 003 Hz 400 Hz 0 012 Hz Contact Outputs 115V AC 30V DC 5 0 Amp Resistive 2 0 Amp Inductive 2 Form C Contacts 2 Form A Contacts All contacts are fully programmable for closure relative to 17 different drive variables selected through the CR1 4 Out Select parameters Encoder Inputs Requirements Line Driver Encoder 5V DC or 8 15V DC Output Minimum Current 10mA per Channel Quadrature or Pulse Single Ended or Differential Maximum Input Frequency 250 kHz Serial Communications Options Remote 1 0 Single drop remote 1 0 to Allen Bradley PLCs and SLC 500 Supports full block transfer and link mode discrete transfer RS232 422 485 DFI Protocol DH485 Protocol Customer Specific Protocol DeviceNet DeviceNet to SCANport module Available for all drive ratings Hex 1 0 Flex 1 0 to SCANport module Available for all drive ratings SLC SLC to SCANport module Available for all drive ratings 10 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Function Description Sensorless Vector Motor Control New vector control adds exceptional torque performance to the 1336 PLUS II N 7X This powerful algorithm provides the following performance enhancements SENSORLESS VECTOR Qutstanding low speed torque at speeds as low as
152. er 68 0 01 Hz 8 33 Base Frequency Slip Adder 255 0 01 Hz 8 33 Base Frequency otor NP RPM 71 1 RPM 60 24000 RPM 1750 RPM otor NP Hertz 78 1 Hertz 1 400 Hz 60 Hz Encoder Counts 283 1 Count 332167 0 Enc Count Scale 282 0 4096 Encoder Loss Sel 284 Settings Selection Parameter Disabled Encoder Freq 63 0 01 Hertz 0 00 400 00 Hz Enc Counts 328 1 Count 0 32767 0 Process PI Speed Control 71 Settings Selection Parame Slip Comp PI Config 213 Bit 1 0 0 00000000 PI Status 214 Bit 1 0 Read Only PI Ref Select 215 Settings Selection Parameter Preset 1 PI Fdbk Select 216 Settings Selection Parameter Analog 1 PI Reference 217 0 01 Hertz 2400 00 Hz Feedback 718 0 01 Hertz 40000 Hz Error 219 0 01 Hertz 2400 00 Hz PI Output 220 0 01 Hertz 2400 00 Hz Process 271 0 1024 128 Process 222 N A 0 1024 256 PI Neg Limit 223 0 01 Hz 3400 00 Hz 8 33 Max Freq PI Pos Limit 224 0 01 Hz 3400 00 Hz 8 33 Max Freq PI Preload 225 0 01 Hz 38 33 Max Freq 0 00 Hz Control Select 9 Settings Selection Parameter Sens Vector Flux Amps Ref 92 0 0 0 75 Drive VT Rtd Amps 0 0A R Drop Volts 94 Vol 0 25 Drive Rated Voltage 0 Volts Flux Up Time 200 0 1 Sec 0 0 5 0 Sec 0 0 Sec Start Boost 48 Vo 0 9 5 Drive Rated Voltage 0 Vo
153. er feedback inputs Refer to Appendix A in Pub 1336 PLUS 5 3 for input impedance values The maximum and minimum wire size accepted by TB3 is 2 1 and 0 30mm 14 and 22 AWG Recommended torque for all terminals is 0 90 1 13 N m 8 10 Ib in Use Copper wire only Digital Inputs Digital inputs are connected at TB3 Input Mode Select A number of combinations are available by first programming Input Mode to the desired control scheme i e 2 wire 3 wire or Status The remaining inputs can then be configured by programming TB3 Term 22 Sel through TB3 term 28 Sel Refer to the Digital 1 0 parameter group in Chapter 6 of Pub 1336 PLUS 5 3 for programming information 1 Uses internal 45V DC supply 2 The encoder loss detection feature of the 1336 PLUS II requires the use of L7E L8E or LIE 41 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Digital 1 0 Default Settings TB3 Input 1 Input 2 Common Input 3 Input 4 Input 5 Common Input 6 Input 7 Input 8 Common Input 9 Encoder B Encoder NOT A Encoder NOT B Encoder A 12 200mA max Encoder Common Input Mode Start Stop Functions Only Status Factory Default Status Stop Fault Reset Status Only Default Mode shown at right is not active when Input Mode is set to Status Included on L4E L7E L5E L8E amp L6E L9ES
154. er to publication Drives BR007A EN P 12 Pulse Front End with Auto Transformer This option provides a 12 pulse drive front end fed by a 12 pulse auto transformer It does not Option MP12A guarantee meeting the guidelines of harmonic specification IEEE519 1992 without a detailed harmonic analysis 12 Pulse Front End with Isolation Transformer This option provides a 12 pulse drive front end fed by a 12 pulse isolation transformer It does not Option MP12N guarantee meeting the guidelines of harmonic specification IEEE519 1992 without a detailed harmonic analysis 18 Pulse Front End with Auto Transformer This option provides an 18 pulse drive front end fed by an 18 pulse auto transformer It will meet the Option MP18A guidelines of IEEE519 1992 at the drive input terminals provided the input power phases are balanced to within 196 18 Pulse Front End with Isolation Transformer This option provides an 18 pulse drive front end fed by an 18 pulse isolation transformer It will meet Option MP18N the guidelines of IEEE519 1992 at the drive input terminals provided the input power phases are balanced to within 296 Motor Interface Options Blower Motor Starter This option provides blower motor fusing an Allen Bradley Bulletin 100 contactor and an Allen Bradley Option MB Bulletin 193 Class 10 thermal overload relay The blower starter is electrically interlocked with the drive enable function or the bypass contactor if bypass is p
155. erminal Block connections shown below are a generic representation intended to show the interface of internal or remote signal and control devices to the terminal block This terminal block is located on the bottom of the main control board Specific TB2 terminal locations may vary by standard drive rating For more information refer to the Standard Drives section The location of user control wire connections to a packaged drive will vary with the particular control options chosen After an order is entered Approval Drawings or Manufacturing Drawings may be ordered prior to shipment and specific customer interconnection information is supplied Programmable Run Fault Fault Alarm Alarm ONLY PRESENT Installing an analog option board in the CR1 CR2 CR3 CR3 CR4 CR4 ON B FRAME DRIVES Slot A or B location will change the N N AND LARGER standard function of these terminals TE TE 9 10 11 12 13 14 15 16 17 18 Al A2 8 E tity A A O AT At standard Drive Contacts Shown In Unpowered State 2 C I I Note If Standard Drive Contacts CR2 CR3 amp CR4 are used A by 1336 PLUS II Configured Drive options JF and or ONLY PRESENT to 0 10 JR and or JM they will not be available for customer ON B FRAME DRIVES TE 4 20mA Input use Refe
156. es on pages 52 and 53 list the maximum recommended cable length for unterminated cables since the voltage doubling phenomenon occurs at different lengths for different drive ratings If your installation requires longer motor cable lengths a reactor or cable terminator is recommended Also refer to these tables for frequency cable length and voltage restrictions of 1204 TFA1 or 1204 TFB2 terminators Optional Output Reactor Bulletin 1321 Reactors listed in the 1336 PLUS 3 0 Price Sheet can be used for drive input and output These reactors are specifically constructed to accommodate IGBT inverter applications with switching frequencies up to 20 kHz They have a UL approved dielectric strength of 4000 volts opposed to a normal rating of 2500 volts The first two and last two turns of each coil are triple insulated to guard against insulation breakdown resulting from high dv dt When using motor line reactors it is recommended that the drive PWM frequency be set to its lowest value to minimize losses in the reactors Important By using an output reactor the effective motor voltage will be lower because of the voltage drop across the reactor this may also mean a reduction of motor torque User Supplied Enclosures 1336 PLUS II drives installed in user supplied enclosures may be mounted within an enclosure or may be mounted to allow the heatsink to extend outside the enclosure Use the following information in combination with the enclosure manufac
157. es that the configured drive has gone through test Certified Motor Dimension Drawing Certified Transformer Dimension Drawing Certified Line Reactor Dimension Drawing Not available if mounted in the drive enclosure AutoCAD Disk copy of order schematics after order has shipped Basic Harmonic Analysis Pre order review of customers one line power distribution diagram Complete Harmonic Analysis Post order detailed Harmonic Spectrum Analysis followed up with a written report Deluxe Harmonic Analysis Post order site verification of actual harmonics detailed Spectrum Analysis and written report Witness Test Customer viewing of A B standard test procedures only Additional tests and documentation per customer requirements are also available Custom Drive Firmware Options 2 Second Power Loss mplementation of a 2 second power loss fault delay time The timer is engaged when the Fault Delay Line Loss Fault parameter is enabled and bus voltage drops below 85 but above minimum Option EN910 bus voltage MOP Reset On Stop MOP frequency source is programmed to reset to zero following a stop Option EN935 60 Hertz Maximum Frequency Option EN945 Maximum frequency of the drive is limited to 60 Hz 1 This option should not be used with other packaged drive options that do not have power fault delay capability Artisan Technology Group Quality Instrumentation Guaranteed 888 88
158. gic to allow interfacing of extraneous control devices to the existing drive logic 113 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Drawing Sample Page 3 Control Logic 21 24 o 00000000 0 115V 2 3065 CR11 CR11 CR11 CR11 el 10 2 s 9 1 PL2 POWER ON PL5 ARE MOTOR FAULT M4 3181 9 01 12 9 10 INPUT CONTACTOR PL11 2 20 DRIVE BYPASS DRIVE MODE w4 3221 3223 a 050 O 1 1 32 AUTO BYPASS OFF NY ON CR14 O OX 555 AUTO BYPASS ENABLE PL12 BYPASS MODE 3302 S 1HS 1000 Jid gas BYPASS MOTOR RUN 3 TME 5 METER 21901 LO dH0 0 1000 314 5 9 Ov 966 OUVW3HOS N N N N N MO gt o s a m a a m 9 8 NS 8 amp G S N B o o ilo o s G 2 S o o BD M The Control Logic page of the drawings contains the control power supply and all associated control ladder logic not found on the previous page The complexity of this page changes dramatically with the number of options chosen Notice the customer interlock locations in the logic to allow remote interfacing 114 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg c
159. gle Channel pulse applications eliminate the B and B NOT connections Some encoders may label the A connection as Signal Important Correct direction of motor rotation as determined during start up may require that the A or B channel wiring be reversed Encoder Power Wiring Internal External o Encoder Power Connections using 12V DC Internal Drive Power Source Minimum On Volts 7V DC Minimum Current 10mA o Encoder Power Connections using External DC Power Source Minimum On Volts 3V DC Minimum Current 10mA Important Control Interface Board jumpers JP3 amp JP4 must be set for the voltage level of the encoder output 45 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Pulse Input Output Option Pulse Input The pulse input signal must be an externally powered square wave pulse at a 5V logic level As measured at the terminal block circuits in the high state must generate a voltage between 3 6 and 5 5V DC at 8 mA Circuits in the low state must generate a voltage between 0 0 and 0 8V DC Maximum input frequency is 250kHz Scale factor Pulse Enc Scale must be set ATTENTION If input voltages are maintained at levels above 12V DC signals may be degraded and component damage may result Pulse Output Provides a TTL pulse train suitable for driving up to three
160. ground junction box and drive cabinet ground These ground connections help minimize interference This is a noise reduction recommendation only and does not affect the requirements for safety grounding No more than three sets of motor leads can be routed through a single conduit This will minimize cross talk that could reduce the effectiveness of the noise reduction methods described If more than three drive motor connections per conduit are required shielded cable as previously described must be used If practical each conduit should contain only one set of motor leads ends For the same reason if a drive sharing a conduit is being serviced or installed all drives using this conduit ATTENTION To avoid a possible shock hazard caused by induced voltages unused wires in the conduit must be grounded at both should be disabled This will eliminate the possible shock hazard from cross coupled drive motor leads Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Motor Cables Motor Lead Lengths Installations with long cables to the motor may require the addition of output reactors or cable terminators to limit voltage reflections at the motor Refer to the following tables for the maximum length cable allowed for various installation techniques For installations that exceed the recommended maximum lengths listed contact the factory MAXIMUM MOTOR
161. he AC line supplying the drive has power factor correction capacitors that are switched in and out an isolation transformer or 5 reactors are recommended between the drive and capacitors If the capacitors are permanently connected and not switched the general rules for impedance mismatch see above apply 3 If the AC line frequently experiences transient power interruptions or significant voltage spikes an isolation transformer or 596 reactors are recommended Refer to Unbalanced Distribution Systems on next page 31 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation AC Supply Source 1336 PLUS II drives are suitable for use on a circuit capable of delivering up to a maximum of 200 000 rms symmetrical amperes 600 volts maximum when used with the AC input line fuses specified on Page 37 ATTENTION To guard against personal injury and or equipment damage caused by improper fusing use only the recommended line fuses specified on Page 37 Unbalanced Distribution Systems This drive is designed to operate on three phase supply systems whose line voltages are symmetrical Surge suppression devices are included to protect the drive from lightning induced overvoltages between line and ground Where the potential exists for abnormally high phase to ground voltages in excess of 12596 of nominal or where the supply ground is tied to another system or equipme
162. ill often require a larger enclosure than the same option in a Option LW Output NEMA type 1 box Reactor Specifications Iron core 3 impedance Class H insulation 115 C rise copper wound 50 60 Hz Common Mode Choke 5 This option will help reduce the common mode noise at the drive output and help guard against Option CM nuisance tripping of the drive caused by capacitive leakage effects Capacitive currents are larger at higher PWM frequencies 76 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options Control and Feedback 0ptions ili Contacts Available 230 460 460VAC VT 575V AC Option JT At Speed Figure 1 0 5 125 HP 0 5 200HP 0 5 250 0924 HP 1 300 HP Option JC Control Power On olloNo Option JF Drive Fault Option JR Drive Run Figure2 250 600 HP 250 325A 600 350 600 HP ollooNo ollooNo Isolated Analog Input This option provides an isolator for the analog input speed reference to the drive and is mounted and Option N3 wired in the drive enclosure The default as shipped setting will be to accept a remote 4 20mA input The isolator may be reconfigured by the user to accept any input signal in the range of 0 256V DC or 0 100mA with or without offset and optional inverse operation This option is generally required when both a local speed pot and a remote speed input are u
163. ime access and local control selection The function of each input is defined through programming For Packaged Drives functions are pre programmed at the factory for a specific application and configuration and should not require field programming Operator control devices provided as part of the drive package will be interfaced to these same input terminals All control input terminals are optically isolated from the drive internal control logic Optional encoder feedback is available for use with single ended or differential type encoders When using a single ended encoder there is a 12V DC power supply available for customer use Differential encoders will require a user supplied power supply Contact Closure Control Interface Circuits used with Option LAC or L7EC must be capable of operating with low true logic Option LAC Without Encoder Feedback In the low state external circuits must be capable of a sinking current of approximately 10 mA to pull Option L7EC With Encoder Feedback the terminal voltage low to 3 0V DC or less In the high state external circuits must allow the terminal voltage to rise to a voltage of 4 0 5 0V DC Note Reed type input devices are recommended The LAC L7EC option is compatible with the following Allen Bradley PLC modules e 1771 0YL e 1771 0ZL 24V AC DC Control Interface 3 Circuits used with Option L5C or L8EC must be capable of operating with high true logic Option L5C Without Encoder Feedback
164. ith reset from the over temperature condition occurring when the resistance is less than 2 2k ohms LA7 Isolated Bipolar This option replaces the two standard analog inputs with two galvanically isolated analog LA7C 2 Input lsolated Input inputs Analog Input 0 is configurable for 10V 20 mA operation with polarity determining forward or reverse operation while Analog Input 1 is configurable for 0 10V 0 20 mA operation 1 Jf a bi polar input option LAB or LA7 is installed the signal is designated Analog Input 0 Note the following 3 Wire Control If Input Mode is set to 3 Wire and the bi polar input is selected as the active frequency reference Freg Select 1 or 2 it is assumed that direction control is desired via analog polarity If another source has control of direction a Bipolar Direction fault F16 will occur If direction control via polarity is not required bit 7 of Direction Mask should be set to 0 This causes the input to be treated as a 0 10V frequency reference only Negative analog signals are treated as zero and direction control must come from another source 2 Wire Control If Input Mode is set to 2 Wire it is assumed that direction control is provided via the 2 wire inputs Run Forward and Run Reverse Bit 7 of Direction Mask must be set to 0 This causes the input to be treated as a 0 10V frequency reference only Negative analog signals are treated as zero Failure to set the M
165. kW 0 5 600 HP Status LEDs Four status indicators located on the control board Dynamic Current Control Multiple sensors Exceptional torque production through Control Proactive current limit control Reduces trips Ability to start low inductance motors A Artisan Technology Group Quality Instrumentation Independent Certification C UL Listed for dual U S and Canadian Certification Designed to meet EN IEC VDE and other international standards Isolated Power and Logic eliminates noise to provide reliable and stable operation DC Cooling Fan on many ratings eliminates the need for a transformer and voltage tapping accommodates global usage Internal Logic Supply from DC Bus does not require separate control power wiring improved ride thru capability Communications Designed to accommodate on board communications for all ratings Guaranteed 888 88 SOURCE www artisantg com Product Description The 1336 PLUS The standard solution to your application needs exceptional reliability when controlling 3 phase motors The output The 1336 PLUS II provides ratings from 0 37 448 kW 0 5 600 HP can be tuned to provide optimum performance for virtually any load in three voltage ranges 200 240V AC 380 480V AC and condition Selectable Refer or V Hz operation provides 500 600V AC The 1336 PLUS II is a micro processor based outstanding motor control adjustable frequency PWM AC d
166. kage may be configured and ordered as desired by the customer the drawing information remains consistent This is especially helpful when multiple drive ratings and or different configurations are ordered The following pages illustrate a typical set of 1336 PLUS II Standard Packaged Drive schematics L1 12 460 VOLTS 3PH 60HZ AC LINES 15 60 AM LINE PE ADAPTER 18 45 TERMINAL BLOCK 1 TERMINAL BLOCK TB2 INTERFACE CONTROL BOARD FOR DETAILED INFORMATION REFER TO PAGE 2 TERMINAL BLOCK TB3 INTERFACE BOARD FOR DETAILED INFORMATION REFER TO PAGE 2 BULLETIN 1336 PLUS DIGITAL AC DRIVE 30 HP CT FOR FURTHER DRIVE INFORMATION REFER TO 460 VOLTS INSTRUCTION MANUAL PUBLICATION 1336 PLUS 5 3 45 0 AMPS 22 1 37 20 21 9 3 160 1 0 224 210 12 22 82 20 08 19 1 FLV RIO ADAPTER FROM PREVIOUS RACK RACK OR PLC TO NEXT RACK H GM1 OR TERMINATING R DETAILED INFORMATION RESISTOR REFER TO PUB 1203 5 1 ADAPTER 2 EA2 HUMAN INTERFACE MODULE fsc E 4 M 9 A pos 1 d Sus MOTOR DATA HP VOLTS FLA RPM BASE 4 NOLNEIXLSIO N3MOd LO 3AlO 9661 OILVW3HOS u AC MOTOR REFER TO MOTOR
167. l Vary with HP See Bottom View Dimensions CS Dimensions in Millimeters and Inches All Weights Kilograms and Pounds C Max gt Mounting Hole Detail 7 0 0 28 SES 777 7 0 0 28 12 7 0 50 lt gt 12 7 0 50 Frame Reference Three Phase Rating 1 2 200 240V 380 480V 500 600V 0 37 0 75 kW 0 37 1 2 kW 0 5 1 HP 0 5 1 5 HP 1 2 1 5 kW 1 5 2 2 kW A2 1 5 2 HP 2 3 HP 2 2 3 7 kW 3 7 kW A3 3 5 HP 5HP 5 5 15 kW 0 75 15 kW M 7 5 20 HP 1 20 HP 5 5 11 kW 11 22 kW B1 B2 7 5 15 HP 15 30 HP 15 22 kW 30 45 kW 18 5 45 kW 6 20 30 40 60 25 60 30 45 kW 45 112 kW 56 93 kW D 40 60 HP 60 150 HP 75 125 HP 56 93 kW 112 187 kW 112 187 kW E 75 125 HP 150 250 HP 150 300 HP 187 336 kW 261 298 kW F 250 450 HP 350 400 HP 187 448 kW 224 448 kW G 250 600 HP 300 600 HP Use care when choosing Frame Reference Some ratings may exist in another frame size Frame Shipping Reference B C Max D E Y 1 AA BB CC Weights M 215 9 290 0 160 0 185 2 275 0 15 35 75 130 0 76 2 85 3 4 31 8 50 11 42 6 30 7 29 10 83 0 60 0 30 5 12 3 00 3 36 9 5 A2 215 9 290 0 180 5 185 2 275 0 15 35 7 5 130 0 76 2 85 3 5 49 8 50 11 42 7 10 7 29 10 83 0 60 0 30 5 12 3 00 3 36 12 1 215 9 290 0
168. le adapter ports while B Frame amp larger drives D A All from Adapter 1 have 6 ports With the possibility of many devices able to issue drive 2 control functions start stop reverse speed reference etc the Typical Jog Mask 1336 PLUS II offers a mask for each control function that gives the user complete flexibility to lock out any function except stop from any port Denies jog from Adapter 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Function Description Traverse Function The 1336 PLUS II output frequency can be programmed to modulate around a set frequency This is accomplished by programming three parameters to develop an inertia compensated triangular waveform Traverse Period Max Traverse and P Jump In surface driven winding applications the waveform developed can be used by traverse drives to perform the traverse function electronically A traverse drive will move the thread back and forth in a diamond pattern to distribute the thread evenly across a tube surface To prevent a build up of thread at the same points on the surface this pattern must be altered This can be accomplished by continuously varying the speed of the traverse in a cyclical manner over a specified speed range With the use of inertia compensation the result is a series of distributed diamond patterns over the entire tube surface 40 4 20 4 Hertz
169. lied for reference purposes only If Class 10 or 30 operation is required refer to the A B Industrial Control Catalog Publication A112 for selection guidance Motor Full Load Amperes for Sizing of Class 20 Heater Elements for Various Options Drive Ratings in kW HP 1 Heater element selection tables taken from A B Industrial Control Catalog Publication A113 110 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 0 37 3 7 0 5 5 5 5 7 5 7 5 10 11 18 5 15 25 22 37 30 50 45 60 56 75 75 100 93 125 0 37 3 7 0 5 5 5 5 18 5 7 5 25 22 30 30 40 37 75 50 100 93 112 125 150 149 187 200 250 224 300 261 373 350 500 Heater 0 37 3 7 0 5 5 5 5 18 5 7 5 25 22 30 30 40 31 15 50 100 93 112 125 150 149 187 200 250 224 300 261 373 350 500 Type W 0 37 3 7 0 5 5 5 5 22 7 5 30 30 45 40 60 56 93 75 125 112 150 149 224 200 300 261 336 350 450 373 500 Number W20 0 49 aU W20 W21 0 54 E W21 W22 0 60 em is W22 W23 0 67 70 M W23 W24 0 74 75 127 W24 W25 0 84 as W25 W26 0 90 2 TA 115 W26 W27 1 00 43 78 125 W27 W28 1 10 45 85 135 W28 W29 1 22 50 94 147 W29 W30 1 31 54 104 165 W30 W31 1 43 59 114 179 W31 W32 1 55 65 125 196 W32 W33 1 66 70 on 139 216 W33 W34 1 80 75 127 150 232 W34 W35 1 97 81 138 160 260 W35 W36 2 12 89 151 175 287 W36 W37 2 3
170. lobal Technical Services specializing in a full spectrum of value added services and expertise to help simplify maintenance and enhance productivity Rockwell Automation is committed to helping you meet ever changing customer demands for more less expensive product in less time Our capabilities enable us to become your Complete Automation partner 1336 FORCE 1336 IMPACT DriveTools32 Flex SLC SCANport SMC SMC Dialog Plus SMP CENTERLINE Complete Automation and the Complete Automation graphic are trademarks of Rockwell Automation DeviceNet is a trademark of the Open DeviceNet Vendor Association ControlNet is a trademark of ControlNet International Ltd www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 1336F TD001E EN P December 2004 Copyright 2004 Rockwell Automation Inc All Rights Reserved Printed in U S A Supersedes 1336F TD001D EN P November 2003 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg
171. logic In the low state circuits must generate a voltage of no more than 30V AC Leakage current must be less than 10 mA into a 6 5k ohm load In the high state circuits must generate a voltage of 90 115V AC 1096 and source a current of approximately 20 mA for each input The L6E L9E options are compatible with these Allen Bradley PLC modules e 1771 0W e 1771 0A e 1771 0WN e 1771 0AD Note Option L6 is the same as Option L6E but without encoder feedback terminals 1The encoder loss detection feature of the 1336 PLUS II requires the use of L7E L8E or L9E Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Specifications Flexible Analog Inputs and Outputs Analog Option Card Slot A No Option Card Two single ended non isolated inputs configurable for a potentiometer reference 0 10V or 0 20 mA signal LA2 Dual Isolated Input Card LAG Isolated Bipolar Isolated Thermistor Input Card 7 Isolated Bipolar Input Isolated Input Card Analog Option Card Slot B No Option Card One single ended non isolated input configurable for a potentiometer reference 0 10V or 0 20 mA signal and two single ended non isolated 0 10V only outputs LAT Dual Analog Output Card LA3 Dual Isolated Output Card LA4 Isolated Input Isolated Output Card LA5 Analog Output Pulse Output Pulse Input Card Digital Inputs and Outputs Digital Input Specifications Frequency Resolution Maximum fr
172. lts Run Boost 83 Vo 0 9 5 Drive Rated Voltage 0 Volts Boost Slope 69 None 1 0 8 0 15 Break Voltage 50 Vol 0 50 Drive Rated Voltage 25 Drive Rtd V Break Frequency 49 Hertz 0 120 Hz 25 Max Freq Base Voltage 8 Vol 25 120 Drive Rated Voltage Drive Rtd Volts Base Frequency 7 Hertz 25 400 Hz 60 Hz Maximum Voltage 20 Vol 25 120 Drive Rated Voltage Drive Rtd Volts Run Accel Volts 317 50 100 100 Sync Loss Sel 310 Settings Selection Parameter Disabled Sync Loss Gain 311 Numeric 0 100 40 Sync Loss Comp 313 Vol 0 25 of Drive Rtd Volts 0 Volts Sync Loss Time 312 Sec 1 30 Sec 5 Sec PWM Comp Time 333 None 20 90 80 Break Freq 334 0 01 Hz 0 30 Hz 0 Hz SLx Logic Step 335 371 Settings Selection Parameter Step On Time SLx Logic Jump 336 372 Settings Selection Parameter Do Not Step SLx Step Jump 337 373 Settings Selection Parameter Jump to 0 SLx Step Setting 338 374 Bit 1 0 0 1 0000 SLx Time 339 375 0 01Sec 0 00 600 00 0 00 Sec SLx Encoder Cnts 340 376 1 Count 32767 0 Current Step 377 None 0 9 0 Firmware 3 001 amp later Firmware 4 001 amp later Firmware 5 001 amp later Guaranteed 888 88 SOURCE www artisantg com e Fault List Over 40 faults can be displayed through the Human Interface Module The display indicates a fault by showing a brief text statement relating to the fault that will be displayed until a drive reset is initiated Fault
173. mand Frequency Output Frequency prive Ramps to Preset Speed k Signal Loss Warning Issued Time Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Function Description Skip Frequencies Many mechanical systems have resonant frequencies that can Frequency cause severe vibration If theses systems are run at these speeds continuously this vibration can cause mechanical breakdowns The 1336 PLUS offers three programmable Skip Frequencies that prevent the drive from running continuously at resonant lt speeds An additional parameter allows a programmable Skip Skip Frequency nd Bandwidth around the skip frequencies Actual Time Process Display In order to provide complete flexibility in monitoring drive performance the 1336 PLUS II offers a Process Mode for the liquid crystal super twist display on the Human Interface Module 1721 6 Tes im This feature provides two lines of 16 characters each that can display any two drive parameters scaled into user selectable units Each line uses 8 value display characters and 8 programmable text characters to create the process display Simple keystrokes can designate the process display as the standard display shown ESC SEL at power A MA Fault Buffer The 1336 PLUS II contains a fault buffer that records the last four faults the drive experience
174. mands forward direction Jog Closing this input starts the drive and causes it to run at programmed jog frequency Opening this input stops the drive using the programmed stop mode Line Loss Closing this input gives exclusive control of drive logic to the inputs at terminal blockTB3 No other devices may issue logic commands excluding Stop to the drive Output Contactor Closed Output contactor auxiliary contact indicates that the output contactor is closed Reverse See Forward above PI Enable Enables the output of the process PI loop PI Reset Opening this input clamps the process PI integrator value at zero Closing this input allows the integrator to continue to operate Run Reverse Available only with two wire control Closing this input issues both a start command and a reverse command to the drive Opening the input issues a stop command to the drive Speed Select 1 2 3 These inputs choose the frequency command source for the drive See following pages for details Stop Type Closing this input selects the stop mode in Stop Select 2 as the method of stopping when a stop command is issued Opening this input selects the stop mode in Stop Select 1 as the method of stopping Sync Normally wired to multiple drives When the Sync input is low the drive operates normally When the input is high the speed of the drive will be held constant and the speed command will have no effect Duri
175. mbient amp Open Drive in 50 C Ambient mamam Derating Factor for Enclosed Drive in Ambient between 41 C amp 50 C Figure L 1336F A075 B150 Figure M 1336F A100 B200 Figure N 1336F A125 B250 Figure 0 1336F BP250 BPR250 Figure P 1336F BP300 BPR300 Figure 0 1336F BP350 BPR350 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 100 96 of Drive 92 Rated Amps 8g _ 84 80 I 4 Carrier Frequency in kHz 100 95 90 of Drive 85 Rated Amps 80 75 70 65 5 4 Carrier Freguency in kHz 100 95 90 of Drive 85 Rated Amps 80 75 70 65 I J 4 60 6 Carrier Frequency in kHz 100 96 of Drive 92 Rated Amps 88 84 80 i I 4 Carrier Frequency in kHz 100 95 90 of Drive 85 Rated Amps 80 75 70 65 7 1 I 4 6 Carrier Frequency in kHz 100 90 of Drive 80 Rated Amps 70 60 50 4 Carrier Frequency in kHz Derating Guidelines mamam Standard Rating for Enclosed Drive in 40 C Ambient amp Open Drive in 50 C Ambient Derating Factor for Enclosed Drive in Ambient between 41 C amp 50 C Figur
176. me eal Speed Select 1 Contact operation for the speed select switch is described in the table below If the user does not select an input as Speed Select 3 Preset Freq 4 7 would not be available Speed Select Input Switch Parameter Used for Programmed Position 1 28 2 27 Speed Ref Setting Local Open Open Freq Select 1 Adapter 1 1 Closed Open Freq Select 2 Preset Freq 1 2 Open Closed Preset Freq 2 20 Hz 3 Closed Closed Preset Freq 3 30 Hz 44 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Encoder Inputs Encoders must be line driver type quadrature or pulse 5V DC or 8 15V DC output single ended or differential and capable of supplying a minimum of 10mA per channel Maximum input frequency is 250 kHz Encoder inputs are available at TB3 The interface board is jumper selectable to accept a 5V TTL or 12V DC square wave with a minimum high state voltage of 3 0V DC TTL or 7 0V DC 12 volt encoder Maximum low state voltage is 0 4V DC Encoder Signal Wiring Single Ended Dual Channel Differential 31 32 3 35 3 1 32 3 35 36 lt m Power Supply Common lt m gt Terminal 36 or External gt lt C TD toTE 12 gt to TE Single Ended Differential Encoder Output Encoder Output Connections Connections 1 For Single Ended Sin
177. me 2 30 0 1 Second 0 0 3600 0 Sec 10 0 Sec Decel Time 2 31 0 1 Second 0 0 3600 0 Sec 10 0 Sec Sync Time 307 0 0 Second 0 0 6000 0 Sec 0 0 Sec Stop Select 1 10 Display Drive None Coast DC Hold Time 12 1Second 0 90 0 Sec 0 0 Sec DC Hold Level 13 196 0 150 96 100 96 Hold Level Sel 231 Settings Selection Parameter DC Hold Lvl Bus Limit En 11 Settings Selection Parameter Disabled otor Type 4 Settings Selection Parameter Induction Stop Select 2 52 Settings Selection Parameter Coast KP Amps 193 NA 25 400 100 Speed Brake En 319 Settings Selection Parameter Disabled Freq Select 1 5 Settings Selection Parameter Adapter 1 Freq Select 2 6 Settings Selection Parameter Preset 1 Jog Frequency 24 0 1 Hertz 0 0 400 0 Hz 10 0 Hz Preset Freq 1 27 0 1 0 0 400 0 Hz 0 0 Hz Preset Freq 2 28 0 1 Hertz 0 0 400 0 Hz 0 0 Hz Preset Freq 3 29 01 Hertz 0 0 400 0 Hz 0 0 Hz Preset Freq 4 73 0 1 Hertz 0 0 400 0 Hz 0 0 Hz Preset Freq 5 74 0 1 0 0 400 0 Hz 0 0 Hz Preset Freq 6 75 0 1 Hertz 0 0 400 0 Hz 0 0 Hz Preset Freq 7 16 0 1 0 0 400 0 Hz 0 0 Hz Skip Freq 1 32 1 Hertz 0 400 Hz 400 Hz Skip Freq 2 33 1 Hertz 0 400 Hz 400 Hz Skip Freq 3 34 1 Hertz 0 400 Hz 400 Hz Skip Freq Band 35 1 Hertz 0 15 Hz 0 Hz OP Increment 22 0 1 Hertz Sec 0 78 Freq Sec 1 1 Hz Sec Save M0P Ref 230 Settings Selection Parameter Disabled Freq Ref SqRoot 229 Settings Selection Parameter Disabled 18 Artisan Technology Group Quality Instrumentation
178. mer 8 Pulse Front End with Auto Transformer 8 Pulse Front End with isolation Transformer Line Metering System Deluxe Line Metering System Basic hermal Overload Class 10 Conformal Coating Analog Input Isolator ransducer Local Command ransducer Local Trim ransducer Remote Command ransducer Remote Trim RTD Protection 120 Ohm Nlckel RTD Protection 10 Ohm Copper RTD Protection 100 Ohm Platinum L UL Panel Recognition Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com All Base Drive Catalog Numbers listed on the A Standard Drive Selection Guide following pages include Drive Branch Fusing A 115V AC Control Interface Card Option L6 Enclosure of Choice 230V Constant NEMA Type 1 IP20 NEMA Type 4 IP65 NEMA Type 12 IP54 Drive Rating General Purpose Resists Water and Dust Industrial Use Dust Tight Nominal HP Code Code Code Al 1 2 2 3 AFOSC AA AFOSC AF AFO5C AJ 3 4 3 0 AFO7C AA AFO7C AF AF07C AJ 1 45 AFT0C AA AF10C AF AF10C AJ A2 11 2 6 0 AF15C AA AF15C AF AF15C AJ 7 80 AF20C AA AF20C AF AF20C AJ A3 3 12 0 AF30C AA 0 AF30C AJ 5 18 0 AF50C AA AF50C AF AF50C AJ 1 71 2 27 0 A007C AA A007C AF A007C AJ B2 10 340 010 010 010 15 480 015 015 A015C AJ C 20 65 0 A020C AA 020 020 25 77 0 A025C AA A025C AF A025C AJ 30 80 0 A030C AA
179. mps has been exceeded 64 Power Overload The drive rating of 15096 for 1 minute has been exceeded 65 Adptr Freq Err The SCANport adapter sent an illegal frequency reference to the drive 66 EEPROM Checksum checksum read from the EEPROM does not match the checksum calculated from the EEPROM data 68 ROM or RAM Fit Internal power up ROM or RAM tests have not executed properly 69 Step Logic Fit SLx Step Jump is set to End Fault or Encoder Counts has reached the endpoint of 32767 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation 1336 PLUS Pre Installation VECTOR N NI NI N NI NI N N 22222 responsibility for the compliance or the noncompliance to code national local or otherwise for the proper ATTENTION The following information is merely a guide for proper installation The Allen Bradley Company cannot assume installation of this drive or associated equipment A hazard of personal injury and or equipment exists if codes are ignored during installation 21 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation IP 20 NEMA Type 1 Dimensions Frames A1 Through A4 Mounting Holes 4 See Detail 66 Bottom View Wil
180. n Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Function Description Many applications require a holding brake function to stop Ramp to Stop motor rotation between operations The 1336 PLUS II provides a programmable DC Hold level and DC Hold time to develop holding torque in the motor after a ramp to stop Volts Speed For applications that require a quick stopping time the 1336 PLUS II can inject a DC voltage into the motor for a programmed time to brake the motor to a stop While this does not take the place of an stop Command Time external brake for emergency stopping it is an effective stopping method under normal operation DC Hold Level Brake to Stop Voltage The drive is capable of extended or unlimited injection braking for both stopping and holding a motor It provides Volts Speed e Injection braking at selectable levels for extended periods up to 90 seconds Level e Extended Hold Braking up to 90 seconds Time Sn Command e Continuous event ended Hold Braking This is accomplished by Ramp to Hold setting the Stop mode to Ramp to Hold In this mode the drive will decelerate according to the programmed decel ramp When the drive reaches zero Hertz output it will supply programmed Reissuing a Start Command at this point will cause the drive to Restart Volts Speed and Ramp as current for hold braking per the DC Hold Lev
181. ng this period the speed input of the drive will normally be changed to a different source and or value Allows synchronized change of frequency command to multiple drives Traverse Setting this input low disables the traverse function When the input is high the traverse function will be active Speed Control must also be set to P Jump for the function to be active Important If a Control Interface Option is not installed the Input Mode parameter must be set to Status default and jumpers must be installed If the drive was shipped from the factory without the option these jumpers will have been installed Important The Input Mode and TB3 Term 22 28 Sel parameters can be changed at any time but the change will not affect drive operation until power to the drive has been removed and bus voltage has decayed completely When changing either parameter it is important to note that the functions of the Start and Stop inputs will change when power is reapplied to the drive Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Digital 1 0 Default Settings TB3 The programming options of the Control Interface Option allow the user to select an input combination to meet the needs of a specific installation The firmware will verify programming to assure an appropriate combination has been selected Speed Select Frequency Reference The drive speed c
182. nge coupled with identical control interface functions device communications training and maintenance provide you with a tremendous advantage in your control needs Add that to integration with Allen Bradley SMC and SMP power products the 1305 drive the 1336 IMPACT and 1336 FORCE field oriented control drives all of which use the same control interface and communication options and you ve just gained significant advantage in system design component integration operator training and maintenance 22 j x v MMIII UOUN Z MM MM EHE EHE ELE HL 8 it Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com MM Alien Bradley Table of Contents 1336 PLUS tt Product Data Product Description 4 OPECHICAIONS osten pe RI RUP UI ERE kk 6 Function 11 Fault and Parameter List 18 1336 PLUS 21 20 NEMA Type 1 Dimensions __ 22 IP 65 54 NEMA Type 4 12 Dimensions 28 20 NEMA Type 1 Bottom View Dimensions 29 Mounting Requirements 31 Iriput GoriditiOnlfig s te RIS 31 AC Supply
183. ngle motor from drive control to bypass across the line operation An SMC Plus with the pump control option solid state controller provides soft start and smooth acceleration capability when first switching to bypass operation and smooth deceleration when stopping in bypass Separate Bulletin 100 where available contactors are provided for drive output SMC output and total bypass All contactors are electrically interlocked A door mounted Drive Off Bypass selector switch is provided Optional Drive Mode and Bypass Mode pilot lights are available option D41 Automatic Bypass with SMC Plus Pump Option 2 3 Option BC This option provides a means to manually or automatically upon a drive fault switch a single motor from drive control to bypass across the line operation An SMC Plus with the pump control option solid state controller provides soft start and smooth acceleration capability when first switching to bypass operation and smooth deceleration when stopping in bypass Separate Bulletin 100 where available contactors are provided for drive output SMC output and total bypass All contactors are electrically interlocked Door mounted Drive Off Bypass and Auto Bypass Off On selector switches are provided Optional Bypass Mode and Auto Bypass Enable On pilot lights are available option D42 Bypass Mode Circuit Breaker Option CC This option is for disconnecting power only and is n
184. noise interference Refer to the table below 1336 PLUS Common Mode Chokes Catalog Number Used with Description 1321 001 Communications Cables Analog Signal Cables etc Open Style Signal Level 1321 M009 All 1336 PLUS Drives Rated Open Style with Terminal Block 9A 480V 0 37 3 7 kW 0 5 5 HP 1321 M048 All 1336 PLUS Drives Rated Open Style 48A 480V 5 5 22 kW 7 5 30 HP 600V 5 5 30 kW 7 5 40 HP 1321 M180 All 1336 PLUS Drives Rated Open Style 180A 480V 30 112 kW 40 X150 HP 600 37 93 kW 50 125 HP 1321 M670 All 1336 PLUS Drives Rated Open Style 670A 480V 112 448 kW 150 600 HP 600V 149 448 kW 200 600 HP Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Cable Termination Optional Cable Terminator Voltage doubling at motor terminals known as reflected wave phenomenon standing wave or transmission line effect can occur when using drives with long motor cables Inverter duty motors with phase to phase insulation ratings of 1200 volts or higher should be used to minimize effects of reflected wave on motor insulation life Applications with non inverter duty motors or any motor with exceptionally long leads may require an output filter or cable terminator A filter or terminator will help limit reflection to the motor to levels which are less than the motor insulation rating The tabl
185. nt that could cause the ground potential to vary with operation suitable isolation is required for the drive Where this potential exists an isolation transformer is strongly recommended Ungrounded Distribution Systems All 1336 PLUS II drives are equipped with an MOV Metal Oxide Varistor that provides voltage surge protection and phase to phase plus phase to ground protection which is designed to meet IEEE 587 The MOV circuit is designed for surge suppression only transient line protection not continuous operation With ungrounded distribution systems the phase to ground MOV connection could become a continuous current path to ground Energy ratings are listed below Exceeding published line to line and line to ground energy ratings may cause physical damage to the MOV R Joules J Line to Line MOV Rating Three Phase S Joules J Includes 2 Line Line MOVs AC Input Joules J Line to Ground M0V Rating Joules J Includes Line Line amp Line Ground MOVs Ground 2 Frame Reference A B G D G Device Rating V AC 240 480 600 240 480 600 240 480 600 Line Line Total 160J 320J 280J 320J 280J 300J Line Ground Total 220J 380 360J 410J 360J 370J 32 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Input Fuses and Circuit Breakers 1336 PLUS II can be installed with either input fuses or an input circuit breaker Local nation
186. ntation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Derating Guidelines Drive ratings can be affected by a number of factors If more than one factor exists derating percentages must be multiplied For example if a 14 Amp drive B007 is installed at a 2 000 m 6 600 ft altitude and has a 2 high input line voltage the actual amp rating will be 14 X 94 Altitude Derate X 96 High Line Derate 12 6 Amps Ambient Temperature Carrier Frequency mamam Standard Rating for Enclosed Drive in 40 C Ambient amp Open Drive in 50 C Ambient mwwm Derating Factor for Enclosed Drive in Ambient between 41 C amp 50 C Figure A 1336F AQF05 AQF75 and BRFO5 BRF200 Figure B 1336F A010 and B020 Figure C 1336F B025 Figure D 1336F A015 and B030 Figure E 1336F B040 and BX040 Artisan Technology Group Quality Instrumentation 100 98 96 of Drive Rated Amps 94 92 90 71 I I 1 1 1 2 4 6 8 10 12 Carrier Freguency in kHz 100 98 of Drive 96 Rated Amps 94 92 90 1 i 7 2 4 6 8 Frequency kHz 100 96 of Drive 92 Rated Amps 999 84 80 2 4 6 Carrier Frequency in kHz 100 95 90 of Drive 85 Rated Amps 80 75 70 65 1 7 1 2 4 6 Carrier Frequency in kHz 100 98 96 of Drive 94 Rated Amps 92 90 88 86
187. ogy Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Drive input fuses are not supplied with the circuit breaker option CB for Frames A E Suggested Power Distribution Schemes Options The power distribution schemes shown below are for typical configurations and offered as suggestions only Actual specified configurations may vary with accepted design practices or code restrictions Oy Circuit Breaker Option CB Drive Branch Fusing Std Output Contactor T Option KM Thermal Overload Relay Option MK or Motor Branch Fusing H Option FM SMC Fusing Tasa PLI 1 This option is redundant to the existing electronic overload protection supplied by the drive as standard 2 If the motor branch fusing option FM or the bypass system circuit breaker option CC are not specified the user must supply motor branch circuit protection 3 Standard drive branch fusing will be located on the optional drive disconnect switch if supplied except F and G Frame drives 4 For F Frame drive ratings the input contactor option will be located ahead of the internal drive branch fusing 5 Line reactor is standard on MP12A and MP18A only 6 Drive branch fusing is standard for Frames F G and H only Bypass System Bypass System Non Fused
188. om Drawing Sample Page 4 Enclosure Panel Layout and Data Nameplate ENCLOSURE DIMENSIONS AND DOOR LAYOUT S 360 14 19 ew 335 13 19 HEAT SUGGESTED SINK CONDUIT ACCESS LT 203 7 99 ByPass DESCRIPTION DESCRIPTION CNTRL PWR ON PL2 9 AUTO MAN 551 RUN PL3 10 H O A 552 NOT USED 11 MODULE EA2 HAND PL9 12 DRIVE MODE PL11 AUTO PLIO 13 BYPASS MODE 12 gt MOTOR FAULT PL5 14__ EN OFF ON 555 0 313 DRIVE FAULT PL4 15 DRV OFF BP SS4 NOT USED 16 RUN TME EA6 23 627 NOT USED 17 DRIV DISABLE PB1 24 7 DIMENSIONS ARE IN MILLIMETERS INCHES 25 78 1125 44 275 7 95 e ojo e w NOTE ENCLOSURE WATTS LOSS IS BASED ON THE CARRIER FREQUENCY OF 4KHZ OPERATION AT HIGHER FREQUENCIES MAY REQUIRE ADDITIONAL COOLING CHASSIS LAYOUT S 31383 23 62 DATA NAMEPLATE 11336 F B030CAA BA CB CC CT D12 D22 D41 D51 FM GM1C HA2C JF JR JC M KD VIVO ANIILNO 330SO1ON3 LO dHOC INYA 9 L 40 LA2C ME SA 15 75 SAMPLE 0001 SAMPLE O001 SAMPLE 0001 2 45 0
189. ommand can be obtained from a number of different sources The source is determined by drive programming and the condition of the Speed Select Inputs on TB3 or reference select bits of command word if PLC controlled Refer to Appendix A in Publication 1336 PLUS 5 3 The default source for a command reference all speed select inputs open is the selection programmed in Freq Select 1 If any of the speed select inputs are closed the drive will use other parameters as the speed command source Refer to the table below and the examples that follow Speed Select Input State vs Frequency Source Speed Select3 Speed Select2 Speed Select 1 Frequency Source Open Open Open Freq Select 1 Open Open Closed Freq Select 2 Accessed through Freq Select 2 parameter Preset Freq 1 Open Closed Open Preset Freq 2 Open Closed Closed Preset Freq 3 Closed Open Open Preset Freq 4 Closed Open Closed Preset Freq 5 Closed Closed Open Preset Freq 6 Closed Closed Closed Preset Freq 7 Important The final speed command may be affected by the type of modulation selected with Speed Control parameter 77 Example Application is to follow a local HIM unless a preset speed is selected The drive is programmed as follows e Freq Select 1 e Freq Select 2 e Preset Freq 1 e Preset Freq 2 e Preset Freq 3 30 Hz Ad 1 1 Local 3 10 Hz X o 2L eal Speed Select 2 220016
190. ons 2 Requires a Communication Option Cable 1202 Cxx to be functional 3 A maximum of one Communication Option may be drive mounted Each Flex 1 0 SCANport Module requires 1 1203 FB1 and 1 1203 FM1 5 Adapter is programmed contigured with Windows HyperTerminal via RS 232 using the 1203 SFC cable purchased separately or using a compatible network specific software tool 67 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS II Selection Guide Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com 1336 PLUS Standard Packaged Drives 1336 PLUS II Standard Packaged Drives Table of Contents PRODUCT DESCRIPTION 70 DRIVE SPECIFICATIONS Input and Output 05 71 Standard AC Line 72 OPTIONS Suggested Power Distribution Schemes 73 Disconnects Control Transformers Overload Relays 74 Bypass Auto Manual SMC 75 Multi pulse Front Ends Motor Interface 76 Power Conditioning Control and Feedback Communication T PLC SLC Control Interface 78 Human Interface 0 79 Door Mounted Operator
191. ontrol power transformer mounted and wired inside the drive enclosure The transformer is rated for drive power plus an additional 500VA at 120V AC for customer use Thermal Overload Relay Options Class 10 Motor Thermal Overload Relay Option MT This option provides an Allen Bradley Bulletin 193 bi metallic thermal overload relay The 193 contains an integral heater element with an adjustable trip setting refer to Motor Thermal Overload Relay Selection in the Selection Guide section No additional heater elements are required A Class 10 overload relay will trip in 10 seconds or less at 600 of motor current setting The motor overload protection provided by this option is redundant to the electronic overload protection provided by the drive itself Class 20 Motor Thermal Overload Relay Option MK This option provides an Allen Bradley Bulletin 592 thermal overload relay The Bulletin 592 contains a manual reset and requires a eutectic alloy heater element refer to Heater Element Selection in the Selection Guide section The heater element is not supplied with this option because specific motor data generally is not known A Class 20 overload relay will trip in 20 seconds or less at 600 of motor current setting The motor overload protection provided by this option is redundant to the electronic overload protection provided by the drive itself Bypass Options Where system downtime cannot be tolerated a bypass option can be
192. or configures that input for 0 10V operation The bottom provides 0 20 mA and the right side provides potentiometer operation Analog Option Board Installation and Removal If the drive is not factory configured with Analog Options LA1 LA2 etc the desired option boards can be user installed Prior to installation the jumpers at 9 and or J10 must be removed If a board is removed at a later time the jumpers must be reinstalled Refer to the detailed instructions supplied with the option boards Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Motor Cables A variety of cable types are acceptable for drive installations For many installations unshielded cable is adequate provided it can be separated from sensitive circuits As an approximate guide allow a spacing of 0 3 meters 1 foot for every 10 meters 32 8 feet of length In all cases long parallel runs must be avoided Do not use cable with an insulation thickness less than or equal to 15 mils 0 4mm 0 015 in The cable should be 4 conductor with the ground lead being connected directly to the drive ground terminal PE and the motor frame ground terminal Shielded Cable Shielded cable is recommended if sensitive circuits or devices are connected or mounted to the machinery driven by the motor The shield must be connected to both the drive ground drive end and motor frame ground motor end Th
193. ossible conflict with this grounding scheme and possible equipment damage E gt lt 5 a N lt ea e B E o o aa oo B 5 2 c gt D lt oO c d N D 8 E E E EE E S 8 gt 5 c e S B 5 E B 5 5 S B B8 EB gt gt c gt lt c gt c LLI Lu LLI 19 2 2 22 23 24 25 26 27 28 29 30 3 3 33 34 35 36 BEES JUI OH T The maximum and minimum wire size accepted by TB3 is 2 1 and 0 30 mm2 14 and 22 AWG Maximum torque for all terminals is 1 36 N m 12 Ib in 1 Packaged drives will generally be factory programmed for the control scheme shown Parameter 241 set to 2 which is a 3 wire control and all other inputs set to default Refer to publication 1336 PLUS 5 3 for further information 104 INCLUDED ONLY ON L7EC L8EC amp LOEC OPTIONS Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Selection Guide Catalog Number Definition ALLEN BRADLEY Base Drive Options as Required 1336F 020 BM GM1C HA1C Product Bulletin No HORSEPOWER VOLTAGE CODE DUTY ENCLOSURE CODE DESCRIPTION CODE DESCRIPTION CODE DESCRIPTION The chart shown on the next page details the segments that make up a Standard P
194. osure Types Packaged Drives are assembled in NEMA Type 1 4 or 12 enclosures with the heatsinks mounted out the back wherever possible G frame drives and certain special NEMA ratings will require internally mounted heatsinks Each enclosure type lends itself to a particular type of protection and environment The enclosures detailed below do not normally protect electrical equipment from condensation corrosion or contamination which may occur within the enclosure or enter via the conduit or unsealed openings Users must make adequate provisions to safeguard against such conditions and satisfy themselves that the equipment is properly protected Other enclosure types are available by custom quotation For further information on criteria associated with NEMA enclosure ratings refer to NEMA Standards Publication NO 250 1991 IP20 NEMA Type 1 Type 1 enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment in locations where unusual service conditions do not exist The enclosures are designed to meet the rod entry and rust resistance design tests Slotted openings in the enclosure sides or door s allow for free exchange of inside and outside air IP54 NEMA Type 12 Type 12 enclosures are intended for indoor use primarily to provide a degree of protection against dust falling dirt and dripping non corrosive liquids They are designed to meet drip dust and rust resistance tests The
195. ot intended for branch circuit protection Branch circuit protection is provided by the bypass fusing option FM Most ratings will utilize a motor circuit protector MCP type breaker Where 5 are not available a circuit breaker will be provided All switches include handle operators door interlocking and are padlockable Bypass Mode Non Fused Disconnect Switch Option DT This option is for disconnecting power only and is not intended for branch circuit protection Branch circuit protection is provided by the bypass fusing option FM An Allen Bradley Bulletin 194R rotary switch is provided on A C frame drives A flange mount or rotary style switch 1494 F where possible is provided on D frame drives and larger All disconnect switches are non fusible door interlocked and padlockable Bypass Mode Motor Fuse Block Option FM This option provides a fuse block only Fuses must be customer supplied and installed This option is used in conjunction with any bypass option for motor branch circuit protection 1 The Bypass Operation capability provided by this option is not intended for maintenance of the drive or entry into the enclosure with power applied while operating in the bypass mode Maintenance Bypass positive lockout is available as a custom option 2 Bypass Options do not include the required 120V AC control power Control power may be supplied remotely by the user or as part of the drive package by ordering a Control
196. peed The amount of slip is proportional to the motor load While this increased slip provides the necessary torque load speed is sacrificed For those applications where this speed decrease is unacceptable the 1336 PLUS II offers Slip Compensation As load increases the drive automatically increases of Speed 1 With Slip Compensation 98 97 v 4 Without Slip Compensation 96 output frequency to provide needed motor slip without a decrease in speed The amount of compensation is proportional to the load 95 RF V o o gt 2o a increase allowing one setting for the entire speed range The 0 10 20 30 40 50 60 70 80 90 100 1336 PLUS II Slip Compensation function can provide typical of Load speed regulation of 0 5 e Slip compensation is based on programmed motor flux instead of drive rated amps providing more accurate speed regulation Slip compensation is active for both steady state and accel decel conditions Dynamic response to load changes is parameter adjustable Slip compensation enhances torque performance at all speeds Some applications require that the drive pick up a spinning load at its current speed and direction then accelerate or decelerate to the actual commanded speed and direction The 1336 PLUS II offers a programmable feature called Flying Start This feature has the ability to determine the speed and direction of a rotating motor and begin its output at that sp
197. r to the 1336 PLUS II Standard Packaged AND LARGER 0 L CT Drive Option Description section for additional TE ccce 10k Ohm information These contacts are reprogrammable Remote Pot to to by the user TE TE 0 10V Analog 0ut User speed reference signals Y Y Y Y negative or common side of these signals at earth ground potential Control schemes must be examined for ATTENTION Signal Common User reference signals are terminated to logic common at TB2 terminal 3 4 or 5 This puts the possible conflicts with this type of grounding scheme 103 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Wire Terminations Control Interface Wiring Drive Terminal Block TB3 Control interface inputs are connected to terminal Block TB3 TB3 is located on the Control Interface Board installed in the drive All 1336 PLUS II Packaged Drives come with a 115V AC Control Interface Card Option L6 unless otherwise specified 24V AC DC control and Contact Closure control are available as options Encoder feedback is available as an option with any of the three control methods All control interface cards provide input terminals for access to fixed drive functions that include start stop and enable Four additional inputs are programmed for functions such as reverse preset speed access jog second accel decel time access and local control selection The function of each input is
198. rS Add a UL option to the catalog string at no charge This option provides UL panel recognition from the factory Drawing and Test Options Approval Drawings Cat No 1301 APPDWG Black amp Whites Cat No 1301 APPRV Velumes One set 11 x 17 electrical schematics and enclosure outlines see sample drawings at the back of this publication Further engineering and manufacture of drive held until drawings are returned approved by the customer and any changes are approved by the manufacturer Manufacturing Drawings Cat No 1301 MFDWG Black amp Whites Cat No 1301 MFRV Velumes One set 11 x 17 electrical schematics and enclosure outlines see sample drawings at the back of this publication Information Only Does not affect drive manufacturing Availability is typically 2 3 weeks prior to shipment of the drive s Final Drawings Cat No 1301 FINDWG Black amp Whites Cat No 1301 FINRV Velumes Cat No 1301 FINRM Mylar One set 11 x 17 electrical schematics and enclosure outlines see sample drawings at the back of this publication Same drawings as shipped with the configured drive instruction book Cat No 1301 TESTR Cat No 1301 CERMTR Cat No 1301 CERXFR Cat No 1301 CERLR Cat No 1301 DISK Cat No 1301 HARM1 Cat No 1301 HARM2 Cat 1301 HARM3 Cat No 1301 WT Special Drawings and Reports Test Report Configured Drive Only Certifi
199. re are no ventilation openings within the enclosure to allow free exchange of inside and outside air Closed loop auxiliary cooling may be required for higher HP ratings Specifications calling for NEMA 12 ventilated enclosures should be reviewed with the factory IP65 NEMA Type 4 Type 4 enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain splashing water and hose directed water and to be undamaged by the formation of ice on the enclosure They are designed to meet hose down dust external icing and rust resistance design tests Doors and openings will be gasket sealed There are no ventilation openings within the enclosure to allow for free exchange of inside and outside air Closed loop auxiliary cooling may be required for higher HP ratings 8 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Enclosures Specifications Material Specifications 84 A Back Plate Chassis for Heatsink Frame Material Finish Finish Spec 1 12 GA Sheet Steel A B Standard Light Gray Paint NEMA Type 1 Low Gloss 40001 109 08 ASA 61 GRAY A B Standard Light Gray Paint NEMA Type 4 12 Powder Coat Low Gloss 40001 108 04 D E 12 GA Sheet Steel A B Standard Gray Paint NEMA Type 1 12 40001 109 02 ASA 49 GRAY F G
200. re shown below Analog 1 0 2 Only Present on B Frame Signal amp Up Drives Common TE Pot Single Ended Single Ended Signal Single Ended Single Ended Single Ended Signal Reference Input 0 Input 1 Common Input 2 Output 0 Output 1 Common 5V 1 Pot 10Vor20mA Pot 10V or 20mA Pot 10V or 20mA 0 10 Only 0 10V Only or select 1 or select 1 Isolated Isolated Isolated Isolated Single Ended Single Ended Single Ended 0 20 IVA InputO Input 0 Input 1 Input 1 6 input 22 Output 0 Output 1 Output 10V or 20 10V or 20mA 10V or 20mA 10V or 20mA N Pot 10 20 10Vor20mA 20mA Only Return Isolated Isolated Thermistor Thermistor Isolated Isolated Isolated Isolated Input 0 Input 0 Isolated Isolated Output 0 Output 0 Output 1 Output 1 10V 20mA 10V 20mA Input Input C 10V or 20mA 1OVor20mA 10Vor20mA 10Vor20mA 0 Isolated Isolated Isolated Isolated M Isolated Isolated Isolated Isolated Input 0 Input 0 Input 1 Input 1 M IFTE Input 2 Input 2 Output 1 Output 1 10V 20mA 10V 20mA 10V or 20mA 10V or 20mA 0 10V or 20mA 10 20 10Vor20mA 10Vor20mA 1 If an Option Board is installed in Slot A the 5V pot reference will not be Single Ended Non Isolated Isolated Isolated available If a 5V source is required it must be user supplied IEEE Output 0 250 kHz 250 kHz 250 kHz
201. rive Its advanced design provides Simplicity Design and programming simplicity is evident in An easy to read Supertwist Liquid Crystal Display gives Condensed packaging that allows for easy mounting 2 lines of 16 characters each for easy one finger installation and wiring in all types of applications programming and drive monitoring Common assembly parts that reduces the need to stock Serial communications that provide easy integration and a multitude of parts access to peripheral equipment Fully compatible with all equi Easy to program parameters that are organized in a group and element structure for quick access to related functions Common options that are used throughout the entire Simple tuning for optimum torque performance Digitally programmable to help provide precise and Configurable 1 0 allows simple connection to many accurate control customer preformed control schemes The 1336 PLUS II uses digitally programmable features to achieve Control inputs and outputs can be programmed to meet nearly precise and consistently accurate control setup and operation every application requirement The drive can be programmed locally from the Human Interface Module or through a serial communications port using a PLC SLC or DriveTools programming software Performance Powerful algorithms provide unparalleled sis vecron performance Starting acceleration and running torque in exces
202. rovided and selected The blower motor will be assumed to be 1 HP unless motor data is supplied with the order Motor Heater Control This option provides the drive control circuitry for an existing motor heater The heater is interlocked Option MH with the drive run relay and will be energized whenever the motor is not running Option includes a Option MH2 4 white Motor Heater On pilot light mounted on the enclosure door Option MH Customer supplied remote 120VAC 360W power Option MH2 120VAC supplied from drive package RTD Protection Module This option provides a door mounted RTD sensing module for over temperature and under temperature protection Each unit will monitor up to 8 motor mounted RTD s and has 3 output relays for alarm trip and fault Customer contacts are rated 5A 250V AC res Option N6A 120 Ohm Nickel RTD Option N7A 10 Ohm Copper RTD Option N8A 100 Ohm Platinum RTD Power Conditioning Options NEMA Type 1 Line Reactor This option provides an open core line reactor which mounts inside the NEMA Type 1 drive enclosure Option LR Input This option may require a larger enclosure than the standard Option 10 Output Reactor Specifications Iron core 3 impedance Class H insulation 115 C rise copper wound 50 60 Hz NEMA Type 4 12 Line Reactor This option provides an open core line reactor which mounts inside NEMA Type 4 or 12 drive enclosures Option LT Input This non ventilated construction w
203. s 230V 5 5 11 kW 7 5 15 HP 460V 11 22 kW 15 30 HP IP20 NEMA Type 1 1000 39 37 1067 42 00 916 36 00 762 30 00 610 24 00 457 18 00 305 12 00 152 6 00 0 WITH 0PTION BAY All dimensions in millimeters and inches e WITHOUT BAY 650 25 59 3 1336 PLUS II 9 24 00 1336 PLUS I 9 DRIVE STD DRIVE STD L 457 11 18 00 ep 9 omy o pese L 305 4 e 12 00 9 152 6 00 Hooo x 6 Bele ze 0 0 152 305 457 600 0 152 305 457 600 6 00 12 00 18 00 23 62 6 00 12 00 18 00 23 62 M B1 And B2 Frame Drives 230V 5 5 11 kW 7 5 15 HP 460V 5 5 22 kW 7 5 30 HP 575V 75 15 kW 1 20 HP IP54 NEMA Type 12 IP65 NEMA Type 4 Consult Allen Bradley when adding additional heat producing components to existing NEMA Type 12 rated drives 1549 61 00 1372 54 00 1219 48 00 1067 42 00 916 36 06 7622 30 00 610 24 00 457 18 00 305 12 00
204. s Altitude 1000 m 3300 ft maximum without derating refer to the Derating Guidelines on Pages 56 60 Ambient Operating Temperature 00 Open 0 to 50 degrees C 32 to 122 degrees F IP20 NEMA Type 1 0 to 40 degrees C 32 to 104 degrees F IP54 NEMA Type 12 0 to 40 degrees C 32 to 104 degrees F IP65 NEMA Type 4 0 to 40 degrees C 32 to 104 degrees F refer to the Derating Guidelines on Pages 56 60 Storage Temperature all constructions 40 to 70 degrees C 40 to 158 degrees F Relative Humidity 5 to 95 non condensing Shock 15G peak for 11 ms duration 1 0 ms Vibration 0 006 inches 0 152 mm displacement 1G peak Agency Certification ULL Listed Lm Lm CSA Certified UL Marked for all applicable directives C Emissions EN 50081 1 EN 50081 2 EN 55011 Class A EN 55011 Class B Immunity EN 50082 1 EN 50082 2 IEC 801 1 2 3 4 6 8 per EN 50082 1 2 Low Voltage EN 60204 1 PREN 50178 1 Note Installation guidelines called out in Appendix C of the 1336 PLUS II User Manual publication 1336 PLUS 5 3 must be adhered to Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Specifications Electrical Specifications Input Data Voltage Tolerance 1096 of Minimum 10 of Maximum Frequency Tolerance 48 62 Hz Input Phases Three Phase input provides full rating for all drives Single Phase oper
205. s of 250 combined with a constant torque speed range of 120 1 allow the 1336 PLUS II to handle the tough applications other drives can t DriveTools PLC SLC and SCANport are registered trademarks of Rockwell Automation Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Specifications AC Input Overvoltage Trip AC Input Undervoltage Trip Bus Overvoltage Trip Bus Undervoltage Trip Nominal Bus Voltage Heat Sink Thermistor Protection Specifications 200 240V Drive 380 480V Drive 500 600V Drive 285V AC 570V AC 690V AC 138V AC 280V AC 343V AC 405V DC 810V DC 1013V DC 200V DC 400V DC 498V DC 324V DC 648V DC 810V DC Monitored by microprocessor overtemp trip Drive Overcurrent Trip Software Current Limit 20 to 16096 of VT rated current Hardware Current Limit 180 to 25096 of VT rated current dependent on drive rating Instantaneous Current Limit 220 to 30096 of VT rated current dependent on drive rating Line transients Up to 6000 volts peak per IEEE C62 41 1991 Control Logic Noise Immunity Showering arc transients up to 1500 volts peak Power Ride Thru 15 milliseconds at full load refer to Page 13 Logic Control Ride Thru 0 5 seconds minimum 2 seconds typical refer to Page 13 Ground Fault Trip Phase to Ground on Drive Output Short Circuit Trip Phase to Phase on Drive Output Environmental Specification
206. s own as insta is provi specia parameter settings 117 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Packaging Programs When Allen Bradley Manufactures YOUr sus Factory Wired Options Drive Package 0 Proper wire and size Neatly bundled and routed Sufficient heat dissipation Separated power control You Can Count On aa Drive Input Output and Bypass Contractors Bypass System Circuit Breaker Door Mounted Operator Devices Bypass Mode Motor Fusing Drive Mechanical Door Interlock Drive Mode Circuit Breaker Digital Meter HIM Cable Drive Input Fusing Frames G amp H Only tan p v LUE E Door Mounted k TB2 Control Operator Devices 7X Terminal Block Control Power TB3 Control Interface Transformer with Fusing Terminal Block Auxiliary Control Terminal Block TB1 Power Relay Logic Terminal Block 60 HP 6 Pulse 460V AC NEMA Type 1 4 or 12 Wall Mounted Packaged Drive with Bypass 118 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com istent Panel rovision for Mountinc onsistent Doo ovision for Lifti Slotted tabs on small drives Slotted chassis holes on Proper electrical Easier operator training small drives Floorplate holes on mechanical clearances larger drives Function
207. se a degradation of motor waveform quality Reactors must have a turn turn insulation rating of 2100 volts or higher 3 Includes wire in conduit Values shown are for nominal input voltage and drive carrier frequency of 2 kHz Consult factory regarding operation at carrier frequencies above 2 kHz Multiply values by 0 85 for high line conditions 5 When used on 600V systems 1329R 1329L motors have a corona inception voltage rating of approximately 1850V 6 These distance restrictions are due to charging of cable capacitance and may vary from application to application Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Output Devices Drive Output Disconnection terminals and is opened during drive operation Any disconnecting means wired to drive output terminals U V and W must be capable of disabling the drive if opened during drive operation An auxiliary contact must be used to simultaneously disable the drive ATTENTION The hazard for injury or death from electric shock may exist if a disconnecting means is wired to drive output Common Mode Cores Common Mode Cores will help reduce the common mode noise at the drive output and guard against interference with other electrical equipment programmable controllers sensors analog circuits etc In addition reducing the PWM carrier frequency will reduce the effects and lower the risk of common mode
208. ssmann JKS 90 20 25 A020C A025C 50 60 050 060 60 BXO60V 100A 3 Bussmann JKS 100 75 075 110 3 Bussmann JKS 110 30 A030C 60 B060C 75 B060V 125A 3 Bussmann JKS 125 40 A040C 75 B075C 100 B075V 100 100 150 3 Bussmann JKS 150 125 C125C 175A 3 Bussmann JKS 175 50 050 100 100 125 B100V 200A 3 Bussmann JKS 200 150 C150C 225A 3 Bussmann JKS 225 60 060 125 150 B125C 150 150 B125V 250A 3 Bussmann JKS 250 75 075 150 150 200 B150V 300A 3 Bussmann JKS 300 200 200 350A 3 Bussmann JKS 350 100 A100C 200 B200C 250 B200V 250 300 C250C CX300C 400A 3 Bussmann JKS 400 300 C300C 400A 3 Gould A2 70C400A 125 125 250 250 250 B250V 450A 3 Bussmann JKS 450 300 B300C 300 350 BX250V B300V 350 C350 450A 3 Gould A3 70C450A 250 BP250C 300 BP250V 450A 3 Gould 7005 450 350 B350C 400 B350V 400 C400C 500A 3 Gould A3 70C500A zs 300 BP300C 350 BP300V 500A 3 Gould 7005 500 400 B400C 450 B400V 450 C450C 600A 3 Gould A3 70C600A 350 400 BP350C BP400C 400 BP350V 600A 3 Gould 7005 600 450 BP450C 450 BP400V u 700A 3 Gould 7005 700 450 500 B450C B500C 500 600 B450V B500V 500 600 C500C 600 800A 3 Gould A3 70C800A 600 B600C 900A 3 Gould A3 70C900A 72 Artisan Technol
209. t terminals 42 UW Short Fault Excessive current has been detected between these two output terminals 43 VW Short Fault Excessive current has been detected between these two output terminals 47 Xsistr Desat Flt Output transistors operating in the active region instead of desaturation Frame C amp Above 48 Reprogram Fault The drive was commanded to write default values to EEPROM 49 Input Phase The drive is operated on single phase power 50 Poles Calc Fault Generated if the calculated value of Motor Poles is less than 2 or greater than 32 91 Bgnd 10ms Over Microprocessor loop fault 52 Fgnd 10ms Over Microprocessor loop fault 53 EE Init Read Trouble reading EEPROM during initialization or gate drive board needs replacing 54 EE Init Value Stored parameter value out of range on initialization 55 Temp Sense Open Heatsink thermistor is open or malfunctioning 56 Precharge Open The precharge circuit was commanded to close but was detected to be open 57 Ground Warning A current path to earth ground in excess of 2 has been detected at one or more of the drive output terminals 58 Blwn Fuse Flt The bus fuse in 30kW 40 HP and up drives has blown 61 ult Prog Input A single source input function has been programmed to more than one input or more than one Run Reverse input 62 III Prog Input Fault Data 98 3 Wire is selected as the Input Mode and one or more digital inputs are programmed to Run Reverse 63 Shear Pin Fault Programmed Current Limit a
210. tage between U V and W An auxiliary contact must be used to simultaneously disable the drive or output component damage may occur ATTENTION Any user supplied disconnecting means wired to drive output terminals U V and W must be capable of disabling User supplied remote drive bypass system ATTENTION An incorrectly customer applied or installed bypass system can result in component damage or reduction in product life The most common causes are e Wiring AC line to drive output or control terminals e Improper bypass or output circuits Output circuits which do not connect directly to the motor Contact Allen Bradley for assistance with application or wiring 1 Packaged drives may have different input fuse ratings than those recommended for equivalent standard 1336 PLUS II drives Packaged drives are rated for a single input voltage not a voltage range and may have fuses resident on the drive F Frame or an optional disconnect switch 2 drive input power option is not supplied incoming power connections are made directly to the drive branch fusing except F or G Frame drives or any drive with bypass 3 fa drive output power option is not supplied motor connections are made directly to drive terminals U V and W 102 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Wire Terminations Control and Signal Wiring Drive Terminal Block TB2 The TB2 T
211. th finger safe terminals and any foreign voltage sources Floor Stand This option converts a wall mounted enclosure to a floor mounted enclosure and adds 12 or 24 to Option EF1 12 High the height of the enclosure Special consideration should be given to the final height of the drive Option EF2 24 High package and corresponding operator devices Nameplate Pin or screw mounted 6 25 x 2 door mounted white lamacoid nameplate with black letters The message Option ET is defined by the customer at order entry if no definition is supplied the nameplate is shipped blank for customer engraving Special Paint Option EP1 1 color Special color s and or type of paint A manufacturer s specification number and or paint chip Option EP2 2 color Option EP3 3 color will be required at order entry Note A special primer specification is considered as one color Space Heater Remote Powered Provides 1 enclosure space heater to help prevent condensation inside the enclosure during periods Option EH of drive inactivity Space heater is energized whenever drive power is removed requires a remote 120V AC power source Option includes a 180W fin strip type heater and a white Enclosure Space Heater On pilot light mounted on the enclosure door If remote power is not available refer to option EH2 Space Heater Locally Powered Provides 1 enclosure space heater to help prevent condensation inside the enclos
212. tilized Analog Inputs Outputs 7 All isolated 1 0 are designed with galvanic isolation This results in an isolation withstand capability of 200V AC from each channel to True Farth TE ground and between channels Analog Interface Port A Choose One Analog Interface Port B Choose One LA2C Two Isolated Configurable Inputs LATC Single ended Non isolated Configurable or Pot amp LA6C One Isolated Bi polar Input 10V or 2 Single ended Non isolated Outputs 20mA and one Isolated Thermistor 1 Configurable 1 20mA Input Isolated Configurable Outputs LA7C One Isolated Bi polar Input 10 and LA4C One Isolated Configurable Input amp Output One Isolated Configurable Input One Isolated Pulse Input amp Output and One Single ended Non isolated Configurable Output 3 15 PSI Transducer Local Feedback This option provides a 4 wire 3 15 PSI transducer mounted inside the enclosure The transducer accepts Option N4C Speed Command air pressure only with a 1 4 NPT fitting and generates an isolated output of 4 20mA proportional to Option N4T Speed Trim the input pressure The 4 20mA signal is fed to the drive as either a speed command or speed trim 3 15 PSI Transducer Remote Feedback This option provides a 2 wire 3 15 PSI transducer as a loose item for remote mounting The transducer Option N5C Speed Command accepts air or fluid pressure with a 1 4 NPT fitting and generates an isolated output of
213. turer s guidelines for sizing Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com User Supplied Enclosures Base Derate A0F05 23 Figure A 13 9 15 11 28 20 AQFO7 3 0 Figure A 15 11 21 15 36 26 AQF10 45 Figure A 17 12 32 23 49 35 AQF15 6 0 Figure A 21 15 42 30 63 46 AQF20 8 0 Figure A 25 18 56 40 81 59 AQF30 12 Figure A 33 24 72 52 105 76 AQF50 18 Figure A 42 30 116 84 158 114 AQF75 22 Figure A 58 186 244 A007 27 No Derate 156 486 642 A010 34 Figure B 200 721 921 A015 48 Figure D 205 819 1024 A020 65 No Derate 210 933 1143 A025 77 No Derate 215 1110 1325 A030 80 No Derate 220 1110 1330 A040 120 Figure G 361 1708 2069 A050 150 Figure H 426 1944 2370 A060 180 Figure J 522 2664 3186 A075 240 Figure L 606 2769 3375 A100 291 Figure M 755 3700 4455 A125 325 Figure N 902 4100 5002 380 480V DRIVES BRF05 12 Figure A 12 9 21 BRF07 17 Figure A 13 15 28 BRF10 23 Figure 15 20 35 BRF15 3 0 Figure 16 12 27 21 43 33 BRF20 4 0 Figure A 19 15 36 28 55 43 BRF30 6 0 Figure A 23 18 54 42 77 60 BRF50 9 0 Figure A 29 23 84 65 113 88 BRF75 15 4 Figure A 58 186 244 BRF100 22 0 Figure A 68 232 300 BRF150 24 0 Figure A 88 332 420 BRF200 21 0 Figure A 96 356 452 B015 27 No Derate 117 486 603 B020 34 Figure B 140 628 768 B025 42 Figure C 141 720 861 B030 48 Figure D 141 820 961 BX040 59 igure E 175 933 1108 B040 65 Fig
214. uaranteed 888 88 SOURCE www artisantg com Page 2 Control Interface Drawing Sample SQNV9 SNOILdO 9 21907 LD dH0 OV 91 NLININE OLLVN3HOS 9 6 INPUT 0 INPUT 1 20 INPUT 1 SIGNAL COMMON 0 10 X INPUT 2 T 0 20 OUTPUT 0 0 10 OUTPUT 1 0 10V SIGNAL COMMON CUSTOMER INTERLOCK W8 2204 CR7 CR7 CR7 CR7 2 e 70 Ne si 9 CR6 CR6 CR6 CR6 12 s 9 CRIOCRIO cRt0 cRIg CRIO 2206 2114 e ho N sls 69 MOD L6 115VAC INTERFACE BOARD START azj Pan AUTO RUN 1 0 3 19 CUST INTERLOCK 05 G as Ps HAND MODE PL9 AUTO MODE CUSTOMER INTERLOCK 2291 PL10 TERMINAL BLOCK TB3 COMMON REVERSE JOG MA Pa w6 AUTO MANUAL 2342 AUXILIARY COMMON SPD SEL 3 SPD SEL 2 8 SPD SEL 1 551 CUSTOMER FROM 3 6 INTERLOCK 2 JL EF 1 2362 2365 COMMON 3 22 W 256 22019 _ 2 01 N N N N N gt a 2 55 BUR NB a G N ENABLE The Control Interface page of the drawings contains the drive Main Control Board and the standard Control Interface Board as well as all the control logic that interfaces to these two boards Several customer interlock locations are included in the lo
215. uirements They can be used in non U S installations where local national codes allow if they are installed per their installation instructions ATTENTION The 1336 PLUS II does not provide input power short circuit protection Specifications for the recommended fuse or A circuit breaker to provide drive input power protection against short circuits are provided 33 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Pre Installation Recommended Protection Devices user supplied Drive Dual Element Motor 2 Catalog Input Output Time Delay Non Time Circuit Circuit E Number Rating Rating Fuse Delay Fuse Breaker Protector 140M Motor Starter with Adjustable Current Range 1336F HP Amps Min Min Amps Available Catalog Numbers A1 F05 0 5 28 23 4 15 3 140M C2E B40 140M D8E B40 F07 075 35 3 0 4 15 7 140M C2E B40 140M D8E B40 F10 1 5 4 4 5 6 15 7 140M C2E B63 140M D8E B63 A2 F15 15 73 6 0 8 20 15 140 2 10 140M D8E C10 140M F8E C10 _ F20 2 97 8 0 10 25 15 140M C2E C10 140M D8E C10 140M F8E C10
216. ult Storage one Clear Faul 51 Settings Selection Parameter Ready Cur Lim Trip En 82 Settings Selection Parameter Disabled Shear Pin Fault 226 Settings Selection Parameter Disabled otor OL Fault 201 Settings Selection Parameter Enabled otor Therm Fit 268 Fault Code Fault Storage Enabled Line Loss Fault 40 Settings Selection Parameter Disabled Blwn Fuse Fit 81 Settings Selection Parameter Enabled Low Bus Fault 91 Settings Selection Parameter Enabled Fault Data 207 Param 1 255 one Fit Motor Mode 143 Settings Read Only one Fit Power Mode 144 Settings Read Only one Fault Frequency 145 0 01 Hertz 0 00 400 00 Hz one Fault Status 1 146 Bit 1 0 Read Only one Fault Status 2 286 Fault Code Fault Storage one Fault Alarms 1 173 Bit 1 0 Read Only Fault Alarms 2 287 Fault Code Fault Storage one Fit Clear Mode 39 Settings Selection Parameter Enabled Ground Warning 204 Settings Selection Parameter Disabled Phase Loss Mode 330 Settings Selection Parameter Disabled Phase Loss Level 331 0 1 Volts 51 10 1 12 7Volts 22 5 45 0 56 2 Volts 9 0 18 0 22 5 Volts Precharge Fault 332 Settings Selection Parameter Enabled Diagnostics Drive Status 59 Bit 1 0 Read Only one Drive Status 2 236 Bit 1 0 Read Only one Application Sts 316 Bit 1 0 Read Only one Drive Alarm 1 60 Bit 1 0 Read Only one Drive Alarm 2 269 Bit 1 0 Read Only one Latched Alarms 1 205 Bit 1 0 Read Only one Latched Alarms 2 270 Bit 1 0 Read Only one nput Status 55 Bit 1 0 Read Only one Freq Sour
217. ure E 175 933 1108 B050 71 Figure F 193 1110 1303 BX060 77 Figure F 193 1110 1303 B060 96 No Derate 361 1708 2069 B075 120 igure G 361 1708 2069 B100 150 igure H 426 1944 2370 B125 180 igure J 522 2664 3186 BX150 180 igure J 606 2769 3375 B150 240 igure L 606 2769 3375 B200 292 igure M 755 3700 4455 250 325 igure 902 4100 5002 BP BPR250 6 322 igure 0 491 4658 5149 250 360 No Derate 902 4100 5002 B300 5 425 No Derate 1005 4805 5810 BP BPR300 357 Figure P 619 5342 5961 350 9 475 No Derate 1055 5455 6510 BP BPR350 421 Figure 733 6039 6772 B400 525 No Derate 1295 6175 7470 BP BPR400 471 Figure R 793 6329 7122 B450 590 No Derate 1335 6875 8210 BPBPR450 5 527 Figure S 931 7000 7931 B500 5 670 Figure T 1395 7525 8920 B600 9 670 Figure T 1485 8767 10252 500 600V DRIVES CWF10 24 Figure U 25 29 54 CWF20 48 Figure U 29 57 86 CWF30 72 Figure U 32 87 119 CWF50 96 Figure U 35 117 152 CWF75 10 Figure U 38 148 186 CWF100 12 Figure U 41 177 718 CWF150 19 Figure U 52 286 338 CWF200 24 Figure U 60 358 418 025 30 No Derate 141 492 633 C030 35 No Derate 141 526 667 C040 45 No Derate 175 678 853 C050 57 No Derate 193 899 1092 C060 62 No Derate 193 981 1174 C075 85 Figure G 361 1533 1894 C100 109 Figure 426 1978 2404 C125 138 Figure K 522 2162 2683 C150 168 Figure V 606 2315 2921 200 252 Figure W 755 3065 3820 250 284 Figure X 890 3625 4515 CX300 300 Figure Y 940 3990 4930 C300 9 300 Figure AB amp AC 926 5015 5941
218. ure during periods of Option EH2 Requires a control drive inactivity Space heater is energized whenever the drive is not in Run status If the space heater power transformer option CF CP or CT is required to run when drive power is removed refer to option EH Filtered Door Openings Only This option provides washable metal mesh filters on the outside of the enclosure door and over all Option EC other vented openings This option applies only to NEMA Type 1 drives Gasketed with Filtered Door Openings This option provides filtering as described in option EC In addition all doors and wall panels will be Option EG gasketed as necessary to prevent unfiltered air from entering the enclosure 81 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Options Codes and Standards Code Standard Action CE European Conference Standard Consult the factory with requirements to meet the separate Low Voltage and or EMC directives In most cases Packaged Drives qualify for Restricted Industrial applications and will only require meeting the Low Voltage directive 519 Harmonic Distortion Levels Provide a one line plant power distribution drawing and the associated harmonic specification to the factory for review A software based harmonic analysis will be performed to determine actual harmonic mitigation requirements ED 5 UL C UL CSA lt gt
219. uto amp anual e e D16 1 The function of the Auto Mode speed reference is dependent upon the programming of Freq Select 2 parameter 6 in the drive The use of an Analog Input Card is recommended for any analog signal being fed to the drive The function of the mode is dependent upon the programming of Jog Freq parameter 24 in the drive Meter Options Motor Run Time Meter This option provides a digital non resettable door mounted elapsed time meter The meter is Option ET r electrically interlocked with the Drive Run relay and Bypass contactor if supplied to indicate actual ime Meter motor operating hours Note The standard internal drive elapsed time meter requires a HIM for viewing and is not operable in the bypass mode Line Metering System Deluxe This option provides a Powermonitor II unit at the point of incoming power to the drive package Option M02 Option includes a powermonitor and a single display Current transformers are supplied as necessary Line Metering System Basic This option provides a Powermonitor 3000 unit at the point of incoming power to the drive package Option MQ3 Option includes a powermonitor and a single display Current transformers are supplied as necessary Enclosure Options Voltage Barriers Protective covers for line side of disconnect switch door mounted devices above 50V Option EB except for devices wi
220. zes that TB1 will accept these are not recommendations 2 Applies to 30 kW 40 HP 200 240V 45 amp 56 kW 60 amp 75 HP 380 480V 56 kW 75 HP 500 600V drives only 3 These configurations of TB1 are stud type terminations and require the use of lug type connectors to terminate the field installed conductors 14 6 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com Power Wiring TB1 A1 A3 Frame 200 240V 0 37 3 5 5 HP Terminal Designations 0 37 3 7 kW 0 380 480V 0 37 3 7 kW 0 5 5 HP Terminal Designations eee DC U GRD DC Dynamic Brake Option To Motor H H P d Required 1 Required Branch Input Fusing Circuit Disconnect AC Input Line 200 240V 5 5 kW 7 5 HP Terminal Designations V T2 wW T3 To Motor 380 480 500 600V 5 5 11 kW 7 5 15 HP Terminal Designations DC D R S T U 380 480V 5 5 15 kW 7 5 20 HP Terminal Designations 500 600V 0 75 15 kW 1 20 HP Terminal Designations Pre Installation eelelelele EE DC