Contents

1. The recommended gauge cross sectional area of the conductor depends on the distance between the power supply and the reader controller the distance between the readers and the controller and on the load at the reader controller This is particularly important when a reader with 5 Volt operation is being used as virtu ally no voltage drop can be allowed between the controller and the reader The table below is for a DC800 with an electric release The total load is 300 mA at 24 V or 600 mA at 12 V 24V Supply 12V Supply Min conductor Min conductor Cable length metres area diameter area diameter mm mm mm mm 0 17 0 46 0 51 0 80 51 100 101 150 151 200 201 250 251 300 Recommended cables Cable between DC800 and reader The readers documentation states what type of cables to be used Considerations concerning earthing 8 screening The cable screens must be connected to protective earth but only in one place in the system Also remember that metal parts in doors or vehicle barriers can be in contact with earth For readers installed on these surfaces the screen must not be connected to the metalwork Avoid placing the cables close to heavy current installations e g lifts and power doors since they may cause disturbance 12 DC800 Installation 8 User Manual LOCK m 4 injeizjejej tro Je na na O MXM bje 300 nf w R
2. to evenings nights weekends and holidays cards Anti passback Anti pass back is way to increase the security even further Anti passback simply means that a card holder may not enter through a door twice unless the card has been used for exiting in the same door This is used to e g prevent users to borrow the card from some one else Anti passback reguires that both Entry and Exit readers are of type BCLINK Also that the door environment is eguipped with some kind of arrangement for allowing only one person at a time pass the door The first time a card is used the DC800 assumes that the card holder wants to enter through the door Entry This means that it is not possible to do an Exit the first time 10 DC800 Installation 8 User Manual Installing the DC800 Installthe DC800 near to the card readers to be controlled by the unit A suitable place might be at the ceiling just above the door NOTE f you are using the DC800 card reader product to control an electric lock strike plate we recommend you to earth the lock The wiring should be as near the lock as possible Installing the BC43 BC43Prox BC43EM readers Install the card reader at a height of 120 140 cm from the floor to the bottom edge of the card reader To cater for disabled persons a suitable height is approximately 95 cm 1 Open the card reader with the key supplied The lock is located on the underside of the reader 2 Fasten the back pl
3. apoul 1801d o SUNNY 18010 o sulnjay epoui 1801d o sulnjay ujese 39U0 piomssed mau 8 7 peas aq 0 suonisod JO ou 191u3 8010 o 54 8010 o 54 48010 o 54 8010 o 54 48010 o 54 8010 o 54 8010 o 54 8 39UO 9SIZTI SSA S1151P 9 piowssed mau 191u3 07 10 10111500 1161s 191u3 10128 UOHJE NIJE2 181 7 e 191u3 440 Jezzng NO 1 zzng ssalng 7 9 qeisouoyw Helv lt UJUJEM L 390 2 9useLu NO 2 euuou NO L 440 66 10 spuo es JO ou 191u3 66 10 spuo es jo ou 191u3 98IZTI SSald Egy SSald Zey SSAld Z y SS3Jd Szy SSald YZY SSald Soy SSald 89V SS ld 99y ss ld zy SSald gey SSdld puewwo A owaw se13 y eqssed nuy p omssed Sueu2 Slajoweled Suiped pied Suuueg weisold Nid p eln le 440 NO Jezzng sseinq agersouow Halv ZuruieM SPEJUOI 1olluouu 1000 euin UJUJEM pjau 100P J3S euin Sulu do 100p jas 510112 19u10 ey UUM JIXJ Sulusey ase 5041 l u plomssed YIM Leys skem y DC800 Installation 8 User Manual 31 Daily use To open the door the user should do either of the following Enter a four digit group code if Group code is the current security level If the wrong group code is entered three times in succession group code is blocked T
4. lnp u s euin se13 s p u s euim WEISOJd du s uoz JWI se q s uoz uul 80 4 sauoz pue aw 8 YIM 3x3 Sulusel a1e 5021 29147 Y plomssed g YM pers skem y DC800 Installation 8 User Manual 28 epoul 180Jd 0 ge Mo 1 dajs O e poul 801d 0 g e MO 1 dajs O e 0000 ssald apo dno 5 801d 0 SUINJaY apow 801d 0 SUIN Jay 18014 0 SUJNJAN 4800 0 SUINJaY 1801d 0 SUJNJAN 01 10 ou lnp u s au 193u3 01 10 ou lnp u s euin 191u3 01 10 ou lnp u s euin 191u3 01 10 ou lnp u s euin 191u3 01 10 ou lnp u s euin 191u3 01 10 ou lnp u s euin 191u3 01 10 ou lnp u s aun 191u3 r d s m apo 4 8 se13 NI apo dnois asueys apo dnois 1349 ZEV SSald Aun s 318801 eu SUISN a NpayIs euin Jas 1349 gey ssald jun2es Nid Ple 9u1 SUISN np u3s euin 3 s 1349 SEY ssald Ay n9as uo p1e5 94 SUISN np u3s euin 1 S 1849 Aq VEY ssald n s po dnoly eu Sulsn a NpayIs euin Jas 1349 EEY ss lq Mun38s uedo eu SUISN np u3s euin jas puewwo SELE 8 UJIM JIXJ Sulusey ase sq31 2914 u piomssed g YUM HEIS SAEM V 29 DC800 Installation 8 User Manual apo 15010 0 Je do a
5. 30 11 59 and 13 00 14 59 on half days day O4 In the evening 8 night time oo oo 08 29 and 18 00 23 59 Monday to Friday day types 1 2 3 4 and 5 See O on next page type 8 See O on next page 07 In the night time oo oo 08 29 and 15 00 23 59 on half days day type 8 See on next page Up to 80 different time zones can be created You may for example define a specific time zone for the cleaning staff Applies between 06 00 and 07 59 day types 1 and 3 DC800 Installation 8 User Manual 00 00 06 00 12 00 18 00 23 59 o e Mon Fri lt e on Fri o Sat Sun 4 e Holidays o o o o Time schedules There are two purposes for creating time schedules e To beable to combine time zones into the same time schedule for an easier control of security levels To be able to combine time zones defined for the time control of specific cards When the desired time schedules have been defined it is an easy task to tie them either to a certain security level or to specific cards Up to 10 different time schedules with each eight time zones can be created This example shows how to include time zones into time schedules the time zones defined in the previous example are used no time schedule that can be changed o2 and o enabling the Group code security level to be assigned to both time zones o3 enabling assignment of the Card only security level to the lunch hour
6. bank or company supplying the card You may also contact Bewator for advice For information on how to activate Bank Lobby Function read the Bank Lobby Function chapter see Table of contents NOTE If Bank Lobby Function is enabled the security level always have to be Card only otherwise the card will not work DC800 Installation 8 User Manual How does the DC800 work DC800 can easily be adapted to the security requirements in a particular building a par ticular day of the week or time of day To make this possible you have to be familiar with the following concepts e Security levels e Time zones e Daytypes e Time schedules e Anti passback Security levels The security level determines what action is reguired to unlock the door The following security levels exist e Unlocked door Neither cards nor codes are needed to unlock the door free access e Group code A four digit code same code for all users is required to unlock the door e Card only The user must use their card to open the door e Card PIN The user must use their card and enter a personal code PIN to unlock the door Toggle function Used together with current security level i e Card only Group code or Card PIN Every second time the card or code is used the door is opened The door remains unlocked until the card code is used the next time or until another security level starts by a time schedule Examples of timing security le
7. codes and cards can be used in parallel 1 2 3 Set DC800 to programming mode Press A21 eoe Enter to which time schedule the code should belong Use 2 digits e g o1 for time schedule 1 Enter a four digit group code The existing code if any will be over written To erase the group code from a time schedule enter 0000 To programme change or erase another group code follow steps 3 4 Press B to leave programming mode DC800 Installation 8 User Manual 19 Set time schedule Door unlocked Set DC800 to programming mode Press A33 Q Q Enter the number of the time schedule to control the Door unlocked security level Use two digits e g 01 for time schedule 1 To remove a time schedule from this secu rity level enter 00 in step 3 instead DC8oo automatically go back to programming mode Press B to leave the program ming mode Set time schedule Group code 1 2 3 Set DC800 to programming mode Press A34 Q Q Enter the number of the time schedule to control the Group code security level Use two digits e g o1 for time schedule 1 To remove a time schedule from this security level enter 00 in step 3 instead DC8oo automatically go back to programming mode Press B to leave the program ming mode Set time schedule Card Only 1 2 3 Set DC800 to programming mode Press A35 Q Q Enter the number of the time schedule to control the Card only se
8. paxlan n 22 Bur ON OFF PERE AE a en n 23 Door monitor contacts ON OFF aaa ena 23 WC 24 A D 25 Calculated x 0 0 re 25 Programming OGITING cani 25 Erase the memory aaa 26 Factory dei odeje 26 Programming overview 27 DIT RR E 31 Choose change PIN code een 31 DUES S yar alla 31 Troublesho00ti ng uu nennen ir ir 32 Technical specification 33 um 34 DC800 Installation 8 User Manual What is the DC800 DC800 a reader controller designed for one door It has a capacity of storing up to 1000 cards Card readers for both entry and exit can be connected BCLINK The DC800 can also be included in a larger systems consisting of several card reader controllers e Stand Alone Programming is done on the DC800 s or the card reader s keypad e Asa component in a small system Programming is done via a connected PC with the Entro Lite software installed and a USB RIF 2 interface Up to eight DC800 can be con nected Information about the installation and how to use it is explained in the sepa rate documentation supplied with the software e Asa component in a large system Programming is done via a connected PC wit
9. 05 kk 9 Artpass DOCK une 9 installing the DC8oo 10 Installing the BC43 BC43Prox BC43EM readers 10 Installing other type of Fender o a ua 10 Dimensioning the CAD 11 Recommended Snai 11 Wiring s Re A OR MERI 12 Using cable gland b huniy sis 14 PO 15 Delia 15 Set DC8oo to programming mode 15 Seeds 15 Changing the password 16 Program UMEZONES cicale 16 Erase E Ume ZO leads 16 Program time SCHEDULES 17 Erase a time schedule ENO A RE 17 Program B6lld Ve a u n u Sau amana AO u es 17 Delete individual holidays 17 Dede 18 Programme change erase group code 18 Set time schedule Door UNIOCKeA inni 19 Set time schedule Group Code 19 Set ume schedule Card ONY scri 19 Set time schedule Card PIN ad 19 Set time schedule Toggle aida 19 Logona care Uu R en 20 Log on a card without the dd 20 Log on Q Series ar OI o s 20 Cancel card WIN TA eek 21 Cancel card MO 21 Bank LOODY FURCHOM aaa 21 4 DC800 Installation 8 User Manual Special settings 2 5 adal 22 Card reading BOTO EBAY 22 57700 iii EI TEV NEVAR 22 Set door held warning UME aaa a
10. 2 magnetic lock Anti passback O OFF O ON a Prefix Bank Lobby Function refix ID Start position Digits with without joker A max 7 P o o o o o o 1 1 1 1 1 Password Muz33 Door Held Warning Time 1 2 3 4 5 2 o 1 2 3 4 Example Means that all cards 5700 5710 5720 5730 5740 5750 5760 5770 5780 5790 in posi tion 04 07 will be accepted DC800 Installation 8 User Manual Holidays Holiday periods No Date MMDD Duration in days Daytype m 37 38 DC800 Installation 8 User Manual Persons Name d ardnumber Time schedule Example Nm Cardnumber Time schedule Smith Willie 12345678 BEWATOR A Siemens Business
11. Ao4 and A16 commands Example If the card number is 5432 enter 00005432 when using the Ao3 Ao4 and A16 commands Set door release time The door release time determines for how long the lock should remain released following a correct transaction The default value is 7 seconds This is hovv to change the opening time if required 1 Set DC8oo to programming mode 2 Press A28 eee 3 Enter the desired door release time between o1 and 99 seconds 4 DC800 automatically go back to programming mode Press B to leave the program ming mode Set door held warning time Ifthe door is still open when the door release time is over a buzzer sounds at the door for the time set as door held warning time The buzzer reminds the person entering to close the door immediately as an alarm is about to go OFF This is how to change the door held warning time if reguired 1 Set DC8oo to programming mode 2 Press A29 eee 3 Enterthe desired door held warninge between o1 and 99 seconds 4 DC800 automatically go back to programming mode Press B to leave the program ming mode DC800 Installation 8 User Manual 23 Buzzer ON OFF The default is that the buzzer is activated If you do not want the buzzer to beep on key presses or door opening it can be turned OFF Note that even when the buzzer is OFF for normal operation it will continue to sound during programming 1 Set DC800 to programming mode 2 Press A65 s 3 Pres
12. DC800 Installation 8 User Manual EN BEWATOR A Siemens Business Copyright O 2006 Bewator AB Solna Material from this manual may only be copied with the consent in writing of Bewator Bewator reserves the right to alter both the content of the manual and the design of the product Document number 81473 5 Bevvator AB develops and markets a complete security product enter that includes access control and alarm Sales installation and servicing are handled by a national dealer netvvork Actions such as unauthorised manipulation copying etc must not be taken vvith the softvvare contained in the products and systems Such actions are regarded as copyright violation and may result in imprisonment or fines and may likevvise lead to an obligation to pay damages and compensation for using the softvvare DC800 Installation 8 User Manual Content What is the DC8oo 5 Features included in the DCS007 siriana 5 Documenting the programming 5 Using non Bewator cards for entrance 6 How does the DC8oo work 7 Security levels un ua kasa ce TA aba ae 7 Examples of timing security levels Sd YR Ero a 7 Time ZONES And dra 8 51506
13. ED LED GREEN LED COM C DO CLK COM D D1 DATA B EWATOR a DC800 READER BEWATOR shi COM D DI DATA DC800 Installation 8 User Manual 13 Lock to be opened with supplied special key The corner details can be lifted and are prepared with knockouts used for sealing or hiding cable entry The position of them should however remain due to mechanical differences They are numbered like this 81284 B1 Lower left corner 81285 B2 lt Upper left corner The box is fastened on the wall with four screws Brackets are supplied to allow for using glands M12x1 5 these are not included If glands shall be used the default washers have to be re moved See picture on next page The cables can either be safely mounted cable goes over the edge or via knockouts in the same edge Prepared with fixing details for securing the cables with cable ties Power in Terminal block nos 1 and 2 10 40V DC or 8 28V AC Opening relay Voltage free contacts Maximum load 2 A Relay for Warning Monostable Alarm by pass Alert or Duress Software controlled When Alert is selected also the tamper switch will activate this relay RS485 connection for system communication Com A 8 Com B to USB RIF 2 Entro Lite next DC800 or SR34i Entro Input for door monitor contact Indicates open or closed door Remote opening input For conne
14. and B to leave programming mode Example If you set start position to 5 and the prefix to 12Ao all cards with 1200 1210 1220 1230 1240 1250 1260 1270 1280 and 1290 from position s will work NOTE1 The Bank Lobby Function will only work with Clock 8 Data mag stripe readers which reads all characters on the card E g BC18 and BC16 UK only NOTE2 If Bank Lobby Function is used do not forget to set security level to Card only command A35 with e g time schedule 01 24 hours all days 22 DC800 Installation 8 User Manual Special settings Card reading parameters When DC800 is delivered the card reader reads positions 9 to 16 on the card or the last 8 positions if they are fewer than 16 If you want to use your own cards and they should be read differently enter from which position on the reader should start reading and how many digits should be read minimum 1 maximum 8 NOTE Previously logged on cards will not work if you change the card parameters 1 Set DC800 to programming mode N Press Ag7 eeo Enter from which digit in the card number 01 40 the digits should be read 3 4 To reset this function to the default setting press A at this point 5 Enter the number of digits to be read 1 8 6 Press B to leave programming mode NOTE Ifless than 8 digits are used in the card number add as many o digits as neces sary to make up an eight digit card number when using the Ao3
15. ate against the wall using three screws 0 0 and according to the illustration below Seal the screw and cable holes with sealant if the unit is exter nally mounted 3 Make sure the back plate is earthed Use a separate cable to the earthing point Make sure the front and back plates are connected with a cable 4 Fitthe front and check that the card reader is securely fastened NS Installing other type of readers Instructions for other type of readers like e g Proximity readers are to be found in sepa rate documentation supplied with these Because the DC8oo allows for several reader interfaces it is important that jumpers for voltage and interfaces are checked in the DC800 NOTE f a 3rd party reader is connected the behaviour of any particular LEDs and buzzer in that reader might not correspond to those referred to in this manual DC800 Installation 8 User Manual 11 Dimensioning the cables It is important to use cables with the correct conductor gauge to keep the voltage drop in the cables as low as possible 12 volt supplies A 12 V electric locking device generally needs at least 11 V to work properly so the voltage at the reader controller should never be less than 11 V 24 volt supplies A 2 V electric locking device generally needs at least 21 V to work properly so the voltage at the reader controller should never be less than 21 V
16. ation of PIN codes based on the card holder s card number Proceed as follows 1 Set DC800 to programming mode 2 Press A24 eoe 3 Enter a 4 digit calculation factor 4 Press B to leave programming mode To disable the function enter 0000 in step 3 The calculation factor is added to the last four digits in the card number Example If the card number is 15278014 and the calculation factor is 4567 the code will be 2571 8014 4567 12571 All the extra result 1 is disregarded X X 8014 4567 12571 Programming barring Another way to increase security is to enable programming barring which means that pro gramming can only be done in the controller not on the card reader NOTE Remember that if the barring is enabled any card have to be logged on or can celled using the digits of the cards See commands Ao3 Ao4 or A14 This is how to enable programming barring 1 Set DC800 to programming mode 2 Press A25 eee 3 Press 1 4 Press B to leave programming mode To disable barring press 0 in step 3 26 Erase the memory DC800 Installation 8 User Manual When the reader controller s memory is erased the default settings are restored see below 1 Open the lid of the controller with the supplied keys 2 PressB 3 Press 112186 4 Press 112186 once again All previously entered data have now been erased The reader controller reverts to the fol lowing settings Facto
17. ction of an exit reguest button push to make Connection of card reader keypad Maximum load 300 mA Maximum distance for BCLINK read ers 100 m dependant on cabling Maximum distance for Clock 8 Data readers e g proximity reader 50 m Jumper for output voltage selection to reader keypad 5V or Vin lt incoming supply Warning Make sure the setting is correct otherwise readers may be damaged Default 5 V Jumper for interface selection CLOCK amp DATA BCLINK or Wiegand 26bit 32bit or 8bit PIN code Default BCLINK Jumper for system configuration Stand Alone Entro Lite or Entro Default Stand Alone Jumper for address selection 1 8 for Entro Lite or Entro Default Address 1 Tamper switch Gives warning if the DC800 controllers lid is opened Note Will also activate the relay in item G when this is setup as Alert Keypad o 9 plus A amp B to program the DC800 The LEDs red yellow 8 green together with the buzzer indicates the different steps in the programming seguences When the DC800 is in idle mode the green LED will flash with approx 5 seconds interval to verify that the DC800 is powered 14 DC800 Installation 8 User Manual Using cable glands In some cases it is desired to secure the cables via glands The housing allows for using glands of M12 dimension 12 mm When the DC8oo is shipped there are washers mounted at the screw holes to allow for different kin
18. curity level Use two digits e g 01 for time schedule 1 To remove a time schedule from this security level enter 00 in step 3 instead DC8oo automatically go back to programming mode Press B to leave the program ming mode Set time schedule Card PIN Set DC800 to programming mode Press A36 Enter the number of the time schedule to control the Card PIN security level Use two digits e g o1 for time schedule 1 To remove a time schedule from this security level enter 00 in step 3 instead DC8oo automatically go back to programming mode Press B to leave the program ming mode Set time schedule Toggle 1 2 3 Set DC800 to programming mode Press A37 Q Q Enter the number of the time schedule to control the Toggle security level Use two digits e g o1 for time schedule 1 To remove a time schedule from this security level enter 00 in step 3 instead DC800 automatically go back to programming mode Press B to leave the program ming mode 20 DC800 Installation 8 User Manual Log on a card with a card Using this function the cards to be used are programmed 1 2 3 Set DC800 to programming mode Press Ao1 Oee Enter the time schedule during which the card s should be valid Use 2 digits e g o1 for time schedule 1 Use the card at the reader If several cards should be valid during the same time schedule use these cards as well When finished press B to
19. d of screw types when fixing it to e g a wall see item C in the picture If glands instead shall be used proceed like below 1 Zi 6 Remove the default washer s Place the gland bracket s on the little location pin to decide which knockout to cut out There are two different positions of he bracket Cut out approx 12 13 mm and mount the supplied gland bracket s Place the gland in the big hole of the bracket and fix it with the nut The cable is then mounted through the outer sleeve and connected to the desired ter minal blocks on the PCB Optionally fix the cable even further using cable ties and then fix the sleeve In the picture below is shown how to mount the gland bracket NOTE The glands are not supplied with the housing only the brackets M12x1 5 DC800 Installation 8 User Manual 15 Programming n the sections below are the instructions on how to program the DC8oo controller To be able to program DC800 you have to set the reader controller to programming mode This is done by entering a six digit code password Although the DC800 should be shipped with default settings we recommended to read and proceed according to the chapter Erase the Memory to ensure that the unit is erased before any programming take place The six digit code password is initially 112233 Buzzer and LEDs During programming you will be guided by the buzzer and the LEDs In this manual the LEDs are illustrated
20. dA Aep ojep MEJS SUIPNIUI s ep JO ou Ja UJ SUSIP 8 s u s y ui Jaquinu pied 1se 191U3 301d 0 SUINJay epoui 480Jd 0 g e Jo I dajs O e apo 1301d 0 g e I dajs O e 18010 o sulnjay epoui 1S01d 0 g e MO 1 dajs ole COMM 212p 19443 07 10 uonisod 1163s i uq apo 1501d 0 g e I dais ole poul 1501d 0 g e 1 2915 ole SUSIP 8 s u s y l JaqUINU pJeo 1511 S1I IP 8 Jaquinu ple 191u3 pied as zdajs ujese 2 SSY ss ld 91 10 spouad Aepijoy sAep 1 OU 40 OU 191U3 91 10 spoued Aepijoy sAep HOU 10J OU 191U3 91 10 pi 191u3 s118Ip 8 Jequinu pied 191u3 pied as 01 10 ou lnp u s uun s uq 01 10 ou lnp u s uun J9 UJ 01 10 ou lnp u s au J9 UJ r d s SSY SSald ma m puewwo spouad Aep Noy sAepnoy ye l q spouad Aep yoy s ep Hoy spouad Aep Noy sAep joy ure1S04d spou d Aepnoy sAepnjoH uon un4 Aqqo7 yueg pues INOUJIM pied ja2ue pied YUM pied 3ue2 Spied JO Salas e uo 801 pied pied uo 801 pied U3IM pled uo 30 8 UUM JIXJ Sulusey ase 5041 29147 u plomssed g YUM 34835 SAEM V S 3 S a D o 2 E 8 n lt O 30 apoul 1804d o SUNAY
21. en a duress code is entered the door is unlocked at the same time as the extra relay is activated for 5 seconds 32 DC800 Installation 8 User Manual Troubleshooting Problem Possiblecause Action Cannot enter program Wrong password Choose a new password ming mode Red LED is lit after two trials Green LED is lit on Lock error Check cable between reader accepted entrance but controller and lock Change the door does not open locks A card is used at the The magnetic reader head Tighten the reader head card reader but nothing is loose happens No beep is The magnetic reader head Clean the reader head using a heard is dirty special cleaning card The reader head is not work Check the cabling Change card ing reader or reader head A card is used at the The card is not logged on Log on the card reader a beep is 3 i N heard but nothing Wrong time Chec m e i es and or happens set calendar clock The card do not work Three wrong PIN in suc Log on the card again and with PIN code cession and the card is choose enter the correct PIN blocked No PIN code have been Program unique PIN codes at chosen for the card reader or use calculated PIN A24 Card only works when Wrong time schedule and Check that the security level Card PIN should apply or security level Card PIN have been pro grammed correctly Group code do not Security level Group code Both the code and the Security work n
22. go back to programming mode Press B one more time to leave programming mode Log on a card without the card Using this function cards can be programmed by keying in the card number 1 2 3 6 7 Set DC800 to programming mode Press Ao3 Oee Enter the time schedule during which the card s should be valid Use 2 digits e g o1 for time schedule 1 Enter the card number on the keypad If several cards should be valid during the same time schedule use these cards as well When finished press B to go back to programming mode Press B one more time to leave programming mode Log on a series of cards Using this function you can quickly log on a contiguous series of cards 1 2 3 Set DC800 to programming mode Press Ao4 Oee Enter the time schedule during which the cards should be valid Use 2 digits e g o1 for time schedule 1 Enter the card number of the first card 8 digits in the series Enter the card number of the last card 8 digits in the series e fthe programming is done at the card reader with keypad the yellow LED lit all the time as the cards are logged on ifthe programming are made at the controller the buzzer in the controller will sound instead It takes approximately 30 seconds to log on 100 cards 1000 cards takes approximately four and a half minutes Press B to leave programming mode DC800 Installation 8 User Manual 21 Cancel card with card Using th
23. h the Bewator Entro software installed and a Segment Controller to control the DC800 NOTE This handbook describes only how the DC800 is installed and programmed in a Stand Alone mode Features included in the DC800 e Different reader type DC800 can be connected to BCLINK CLOCK amp DATA as well as WIEGAN26 BIT WIEGAND32 bit and WIEGAND 8 bit PIN code readers e Bank Lobby Function It is possible to use one or several types of cards e g American Express or Visa This operates using prefixes see section Bank Lobby Function Five different security levels Various methods of opening the door e g Card only Card PIN and Group code Built in time clock Enables time control of cards and security levels Holidays half days and holiday periods can be pre programmed e Door Monitoring Enables activation of an alarm if the door is forced open or held open too long A duress function is integrated to protect an User from threats from an intruder Anti passback An entry access must be followed by an exit access with the same card Requires two BCLINK readers e Automatic adjustment of clock for daylight saving According to European standard last Sunday in March and October Documenting the programming When the DC800 is used as a stand alone unit is it very important that any changes of e g time schedules and a card parameters is continuously logged manually due to the fact that no printout can be done
24. in the following way O OFF e lit Flashes In programming mode before a function is chosen All three LEDs are flashing During programming The LEDs are lit or OFF depending on the function being pro grammed Correct programming Confirmed by a rising signal consisting of two quick beeps Faulty programming Confirmed by a falling signal consisting of one long and one short beep See also troubleshooting at the end of this manual NOTE f having entered programming mode no key is pressed within 60 seconds the unit will leave programming mode Using the reader for programming If you have a BC43 with keypad you can optionally use this or the DC800 for program ming If only the DC800 shall be allowed for programming it is possible to inhibit the alter native with BC43 See chapter Programming barring Set DC800 to programming mode To program a function the controller has to be in the programming mode All programming is done from the controller s or the card reader s keypad 1 Press B 00 2 Enter the 6 digit password 33 The reader controller is now in programming mode NOTE Ifthe wrong password is entered twice in succession the reader controller is blocked from further attempts for 40 seconds Set time and date 1 Set DC800 to programming mode 2 Press A23 eee 3 Enter the current year month and date e g 050921 for the 21 of September 2005 4 Enter the current day of the week Examp
25. is function a card can be cancelled with the card so that it cannot be used in the card reader 1 Set DC800 to programming mode 2 Press A14 eoo 3 Usethe card at the reader If several cards should be valid during the same time schedule use these cards as well 4 When finished press B to go back to programming mode 5 Press B one more time to leave programming mode Cancel card without card Using this function cards can be cancelled using the card number 1 Set DC8oo to programming mode 2 Press A16 eoo 3 Enter the card number If the card is not logged on the faulty programming signal is heard 4 Cancel the next card as required 5 When finished press B to go back to programming mode 6 Press B one more time to leave programming mode Bank Lobby Function Using this function DC800 can be programmed so mag stripe cards of a certain type e g credit cards can be used for entrance Up to 15 prefixes can be programmed Note that simultaneously it is possible to use cards programmed with the commands Ao1 Ao3 or A04 Proceed like this 1 Set DC800 to programming mode 2 Press Ag8 eeo 3 Enterthe identity of the prefix 01 15 4 Enter from which position in the card number o1 40 the digits should be read To remove an existing prefix enter 00 5 Enter which digits maximum 7 to be read Press A in the desired place to enter a wild card digit E g 12 6 Press B to end the command
26. le 1 Monday 2 Tuesday etc 5 Enter the current time e g 1601 for one minute past 4 PM DC8oo automatically goes back to programming mode 16 DC800 Installation 8 User Manual Changing the password 1 2 3 4 Set DC800 to programming mode Press A27 Enter the new password A warning tone is heard Enter the new password again The warning tone sounds until all six digits have been entered Program time zones This function is used to program the time zones to be used in the installation 1 2 3 10 Take out the completed Time zone chart s Set DC800 to programming mode Press A31 Enter the number of the time zone to be programmed Use two digits e g 1 for time zone 1 Enter the starting time of the first time interval using four digits e g o800 for 8 AM Enter the finishing time of the first time interval using four digits e g 1159 for 11 59 PM If there is no need for a second time interval press A to skip and go to step 9 Enter the start time of the second time interval using four digits e g 1300 for 1 PM Enter the stop time of the second time interval using four digits e g 1659 for 4 59 PM Enter the desired day type s for this time zone Press B and go to step 4 to program another time zone or press B twice to go back to programming mode Erase a time zone Set DC800 to programming mode Press A31 Enter the number of the time zone to be erased P
27. no RS232 interface available NOTE f instead the Entro Lite software and a PC is used the information and events can be printed on the PC s normal printer 6 DC800 Installation 8 User Manual Using non Bewator cards for entrance In DC800 mag stripe cards of different types e g credit cards or some organisation s special card can be used for access This is possible by programming the card s prefix in the DC800 It is possible to combine the use of these cards with the normal cards pro grammed via the standard procedures NOTE Because all positions have to be read and then evaluated the reader MUST be of type Clock 8 Data and reading mag stripe card E g BC18 or BC16 UK only Example 1 Cards with exact prefix The card number is 5760 0096 0029 5679 The four first digits the prefix identifies the card as a certain bank s card Example 2 Cards with some wild card digits When programming a prefix a digit in the prefix can be substituted for a wild card Any digit may occur in the wild card s place to make the card valid If a prefix is programmed as 12570 cards using the prefixes 125700 125710 125720 125730 125740 125750 125760 125770 125780 and 125790 will be valid In DC800 15 prefixes can be programmed Each prefix may consist of maximum 7 digits The first digit in the prefix may begin at any position on the card Information about pre fixes on different cards can be obtained from the
28. o release the blockage enter the correct group code twice in succession Use a card tag if Card only or Group code is the current security level Use a card and enter a personal code belonging to the card if Card PIN is the current security level Should the wrong PIN code be entered 3 times in succession the card is automatically cancelled and must be logged on once again The toggle function Ifthe toggle function is activated the user can open the door in one of the above men tioned ways depending on the current security level The door remains open until a user need not be the same one as opened the door again completes a valid transaction or until another security level starts Choose change PIN code To choose change your individual PIN Duress NOTE If Calculated PIN is used this function does not work Press A on the reader controller s keypad eoo Use your card at the reader eeo If it is the first time you are setting a PIN code for this card enter 0000 Otherwise enter the existing code Enter the new code using four digits Enter the new code again OOO The card is ready to use This is what the cardholder should do to activate a duress alarm if forced to open the door under threat 1 2 Use the card as usual Enter the usual PIN only add 1 to the last digit in the PIN code Example 1 If the PIN is 1234 press 1235 instead Example 2 If the PIN is 1239 press 1230 instead Wh
29. ot programmed level must be programmed A21 amp A34 The Door monitor func The function wrongly pro Program Door monitor function tion do work properly grammed A66 correct The function chosen but Check cables and program incorrect cable connection function correct DC800 Installation 8 User Manual Technical specification Power supply Power consumption Relay outputs nputs nterface Temperature range Dimensions WxHxD mm 33 10 40V DC 8 28 V AC Maximum 200 mA 24Vdc excluding reader Opening relay Maximum 2A 30 V DC Extra relay Maximum 2A 30 V DC Normally pulled high Active when pulled low i e o V RS485 connection To PC via USB RIF 2 To next DC800 e To Bevvator Entro Segment controller 35 Cto 50 C at go air humidity 250X128 X54 34 DC800 Installation 8 User Manual Charts Time zones ist 77 2nd Day type s From From DC800 Installation 8 User Manual Time schedules Time zones included Example No Name 7 UC Timezones included Office staff The example above includes the time zones 1 2 3 and 5 in time schedule 1 Security levels Level Time schedules 35 36 DC800 Installation 8 User Manual Special settings Default inst llning Function extra O Warning 1 O Alert 2 Warning 1 relay 2 O Monostable 3 O Duress 4 OFF DONO O Door monitor O OFF 9 ON 1 normal OFF contact CJ ON
30. ress A DC800 Installation 8 User Manual 17 Program time schedules This function is used to program the time schedules to be used in the installation 1 2 3 Take out the completed Time schedule chart s Set DC800 to programming mode Press A32 Enter the number of the time schedule to be programmed Use two digits e g 1 for time schedule 1 Enter the time zones maximum 8 to be included in the time schedule Example To include time zones 1 2 and 4 enter 010204 Press B and go to step 4 to program another time schedule or press B twice to go back to programming mode NOTE Remember that if you unintentionally program overlapping time schedules used for the security levels the highest security level apply in the following order Closed Door Card PIN Card Group code and Unlocked Erase a time schedule 1 2 3 4 Set DC800 to programming mode Press A32 Q Q Enter the number of the time schedule to be erased Press A Program holidays This function is used to pre program holidays that do not occur on Sundays and holiday periods The total number of holidays and or holiday periods are 15 1 2 3 4 5 Set DC800 to programming mode Press A51 eeo Enter the number of the holiday using two digits 01 15 Enter the date of the holiday e g 1224 for the 24 of December If you program only one holiday press o1 If a holiday period is being programmed enter
31. ry settings Password 112233 Programming barring OFF o Buzzer ON 1 Door monitor contacts OFF o Extra relay Warning 1 Anti passback OFF o Group code None Opening time 7 seconds Door Held Warning Time 10 seconds Card parameters Position 9 16 the last 8 positions if fewer than 16 positions Bank Lobby Function Time zone 01 None 00 00 23 59 day types 1 7 Time schedule 01 Time zone 01 Security level Group code 27 DC800 Installation 8 User Manual ing overview Programm apo ugod indu 0 g e WIYUOI Mo 0 g I dajs OL e SSald 8 d s 1 WWHH e 191ul puz JO au dojs J91u3 1804 0 g e do 1 dajs ol 9 dajs o dpjs 01 V ssald WWHH eAJ91uI puz 10 uul 1461s 191u3 apow 8010 sumas poul 18010 0 SUINJay indu uuu UO2 0 g SSAd poul 18010 0 SUINJay WWHH e 19 UI JST JOJ euin dojs 191u3 WWHH euin juauno y SS 1d p pni ul s ou uoz aWI V SS 1d WWHH 8A4 1Uu JST 10 QUI 1615 191u3 2 1 edA Aep jueuno 191u3 01 10 ou ln p u s DU 01 10 ou ln p u s DU 08 10 ou uoz ull 191u3 08 10 OU uoz al QQWWAA 9 ep 1uaJIno t ZEY SSald ZEY SSald LEY SSald LEY SSald EZY SSald muasir s
32. s o 4 Press B to leave programming mode To reactivate the buzzer press 1 in step 3 instead Door monitor contacts ON OFF If door monitor contacts are used and this function is activated a warning signal sounds during the time set as door held warning time i e when the opening time has expired and the door is still open This is how to make the settings 1 Set DC800 to programming mode 2 Press A66 es 3 Press any of the follovving o lt door contacts deactivated 1 door contacts activated normal 2 door contacts activated magnetic locks 4 Press B to leave programming mode 24 DC800 Installation 8 User Manual Function for extra relay In the DC800 there exist an extra relay to be used for three different functions Warning Alert Monostable Alarm by pass or Duress The diagram shows the function of the relay with different setup Note that only one of the settings is possible Opening time Door Held Warning Time Doorcontact return n lt F Q Warning 1 c Alert 2 Monostable 3 Warning Access is granted and the door is opened monitor contact breaks If door is still open after Opening Time the relay changes over and remains until door is closed Alert Access is granted and the door is opened monitor contact breaks If door is still open after Door Held Warning Time the relay changes over and remains until door is closed Note that this selection
33. the duration in days of the period with two digits including the starting date Enter the day type to apply for this holiday holiday period e g 7 for Sunday Follow steps 3 6 to enter a new holiday holiday period or press B to go back to pro gramming mode Delete individual holidays This function is used to delete individual holidays as distinct to deleting all programmed holidays see the next section 1 2 3 4 Set DC800 to programming mode Press A52 eeo Enter the number of the holiday e g o1 Press B to go back to programming mode 18 DC800 Installation 8 User Manual Delete all holidays This function is used to delete all programmed holidays 1 2 3 Set DC800 to programming mode Press Ass eeo Press A55 one more time DC800 automatically goes back to programming mode Programme change erase group code This is how to program a group code You can program a maximum of 10 group codes Remember that the security level must be set command A34 to work at the same time as the group codes Otherwise the group codes will not work In the opposite way different time schedules for group codes can be used to disable when group codes shall work E g if the security level is Group code one code can work daytime and another in the nigthtime Note that the security level Group code also allow for users by convenience to use valid access cards to enter a door That is both 4 digit
34. times of the day e To beable to make certain cards valid at certain times Example The working hours in an office could be as follows Monday to Friday 08 30 11 59 and 13 00 17 59 Saturdays Sundays and Closed holidays Holidays e g the day 08 30 11 59 and 13 00 14 59 before Christmas To make the reader controller understand that holidays e g Christmas Eve and holiday periods should not be treated as ordinary working days this information must be pro grammed NOTE A time zone is valid from and including the first second in the first minute up to and including the last second in the last minute So a 24 hour day is programmed as 00 00 23 59 The day type determines what day of the week the time zone applies 1 Monday 2 Tuesday etc 8 is an extra day type that can be used for holidays e g the day before Christmas Each time zone may consist of two intervals To be able to assign suitable security levels to the office example above the following time zones are needed no 01 Applies 24 hours a day all day types Note Default time zone that can be changed See on next page o2 08 30 11 59 and 13 00 17 59 Monday to Friday day types 1 2 3 4 and 5 See on next page 3 During lunch 12 00 12 59 Monday to Friday and half days day types 1 2 3 4 5 and 8 See O on next page On Saturdays and Sundays oo oo 23 59 day types 6 and 7 See Gon next page During working hours 08
35. vels During office hours when there are people in the premises the security level may not need to be high Unlocked door or Group code may be suitable levels During lunchtime the level may be raised to Card only The remaining time i e eve nings nights and weekends Card PIN is a suitable security level The Toggle function can be used in premises where a person is responsible during cer tain hours e g a classroom or a loading bay door In a classroom the teacher can open the door which remains open until he or she locks the door The pupils may come in and out without having cards or group code NOTE DC800 has by default the security level Group code with time schedule o1 tied to time zone ot oo oo 23 59 all days This means that if a group code is pro grammed command A21 it will be valid 24 hours a day A valid card can then also be used in parallel Overlapping security levels Remember that if you unintentionally program overlapping time schedules used for the security levels the highest security level apply in the following order Closed Door Card PIN Card only Group code and Unlocked E g if Card only is using time schedule 08 00 16 59 but Card PIN is using time schedule 12 00 12 59 Card PIN will be overriding due to higher priority 8 DC800 Installation 8 User Manual Time zones and day types There are two purposes of creating time zones e To be able to assign different security levels to different
36. will also allow the tamper switch to control the relay If the lid is opened the tamper switch breaks the relay changes over and remains until the lid is closed Monostable The relay changes over and remain during both the Opening Time and the Door Held Warning Time Will return automatically if the door is closed during these periods This can be used for by passing an intruder alarm system monostable mode Duress If the security level is Card PIN the user can when threatened raise the last digit in the PIN code 1 to 2 o to 9 etc A 5 second long pulse is gen erated on the relay output beside unlocking the door The duress signal can be sent to an external alarm system for further action Proceed like this to select the function 1 Set DC8oo to programming mode 2 Press A68 eee 3 Press one of the following 1 Warning function default 2 Alert Tamper 3 lt Monostable 4 Duress 4 Press B to leave programming mode DC800 Installation 8 User Manual 25 Anti passback Anti passback only works with card readers of the BC link type where the reader can be set to be an Entry or Exit reader This is how to activate anti passback 1 Set DC800 to programming mode 2 Press A63 3 Press 1 To deactivate anti passback press 4 Press B to leave programming mode Calculated PIN f it is preferred not to have the users choose their own PIN codes this function will enable automatic calcul