1. Limit hand Spacer p F aes under the spacer ee a Bezel clamp Lifting Lever es ced C Fit the groove in the lifting lever bracket Seo B Bezel T I Release under the screw head which can then Stem 06 00 be tightened A PS ii Indicator Y Spindle 7 i Dial type 4 P OESS 10 Instructions for Use m a Passien f IN EA g 1 Wipe the contact point and surface of the measuring table to remove any dust If there is damage to the measuring table refer to section 6 and _Measuring table soma ben Measuring table request repairs or move the center of the contact point away from the position of the damage for use D a 2 Adjust the height of the measuring table and securely fix the measuring table clamp Frame a vere Frame KERER me 3 Set the reference point xp ype Specify the measuring table or master gage such as the gauge block as the reference surface Specifying the master gage as the reference surface is E 7 fae recommended to avoid damage to the measuring table Measuring table clamp Measuring table clamp 4 Set the measuring table or master gage gauge block etc as the reference surface 5 Specifications Use the lifting lever and release to move the contact point up and down several times Check that the graduation value when the contact point touches Measuring Range Contact Measuring Table the
2. User s Manual Upright Gage Dial Type Digital Type No 99MAG020B3 f 7 Attaching and Removing Limit Hand Dial Type 8 Attaching Bezel Clamp Dial Type Series No 7 547 g g ype g p ype Separate the limit hand Attachment Removal i Clamp screw z ao Limit hand i B Introduction before attaching it B A a Attachment Please read this user s manual before using the gage Store this manual in an easily accessible place after reading it Las Clamping plate A insert clamp bracket in the Export Control Compliance SSK A dovetail groove The goods technologies or software described herein may be subject to National or International or Japanese Export Controls To export directly or indirectly such Clamp bracket B Fix with clamp screw matter without due approval from the appropriate authorities may therefore be a breach of export control regulations and the law i P 1 Safety Precautions Take care not to A A injure yourself when U sd Note Take note that the clamp may loosen A separating the limit A Attach the limit hand to the a To remove the limit or fall off under vibration Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury or property damage hand or handling the bezel Bo hand push it up in the i SS Caution B Push the limit hand all the direction of the arrow Caution separated parts way until it clicks 2 On Various Types of Notes 9 Attaching and Remov
3. asured dimension is the sum of the indicated value and the master gage f o 1 2 0 to 30 mm i j S48 carbide 57 7 ith lifting lever A 547 034 t9 5 10 to 12 mm 201 1D C1012EB 0 01 mm Eee pont jga mm 3 um 8 20 mm Frame Type B dimension This does not apply when using the PRESET function Dio 120030 mm 543 2525 D0005 S carbide 157 DIA F ar Wil Telas Slowly return the contact point to the original position when adjusting the reference measuring a workpiece or after completing 547 035 9 to 5 0 to 12 mm 00015 ID C112EB 0 001 mm contact point 1440 mm Hm mm Frame Type B measurement Repeatedly dropping the contact point and causing it to contact the measuring table might damage the 0 to 30 mm 543 270B S carbide With lifting lever measuring table master gage or workpiece 941 054 0 to 12 mm 20umM ap c1012B 001mm a point p40 mm 3 um 20 mm Frame Type B g ait p z Reference Tolerance judgment 547 055 0 to 30 mm 3 um 543 250B 0 001 mm S48 carbide 40 mm 3 um 20 mm With release a ue p i A 0 to 12 mm aa ID C112B contact point Frame Type B It is possible to set the gage to indicate whether the measured dimension is within tolerance as follows Limit hand is not included in No 7056 e Dial type gage Set the tolerance by attaching a limit hand to the positions of the upper and lower limit values Judge whether the Reference Optional Accessories workpiece dimensions are within the
4. hich a neutral detergent has been Be sure to check the accuracy of gage if it has been dropped or otherwise subjected to shock applied If the contact point of the indicator repeatedly contacts the measuring table the measuring table might be damaged If a bulge results from damaging the measuring table the measuring table must be ground again Ask Mitutoyo for repairs in this case Even if a bulge is not caused the zero position of the indicated value might become incorrect due to the damage To use the dial gage move the tip of the contact point away from the position of the measuring table damage by loosening the portion for fixing the indicator in place and rotating the indicator for models that have the type A frame or rotating the measuring table for models that have the type B frame Ensure that the spindle and hands operate smoothly Also check that the digital display is working normally Remove dirt or dust on the bezel or digital display surface using a soft dry cloth or a cloth on which a neutral detergent has been applied If you will not use the upright gage for a long period of time apply a little anti corrosive oil to the top of the measuring table and the bottom of the frame before putting the gage into storage The performance deterioration of this gage differs greatly depending on the usage conditions Customers are therefore advised Ensure that the contact point and screw are not loose to establish in house standa
5. ing the Lifting Lever IMPORTANT Animportant note provides information essential to the completion of a task Attachment Dial Type Removal Dial Type An important note is a type of precaution which if neglected could result in a loss of data decreased accuracy or instrument A Lift the spindle and fit the forked end of i a Push the finger rest up in the matfune ton fallure the lifting lever to the spindle stop direction of the arrow and under the spacer remove the lifting lever NOTE A note emphasizes or supplements important points of the main text B Fit the lifting lever into the dovetail 3 Operating Environment groove and fix in position by pushing down in the direction of the arrow IMPORTANT Use the gage in an environment with a temperature of 0 to 40 C and a relative humidity of 30 to 70 ee Avoid sudden changes in temperature Condensation may negatively affect the performance of the gage Use the gage in a place with minimal exposure to dust oil and oil mist Attachment Digital Type Removal Digital Type Use the gage in a place out of direct sunlight A Loosen the screw in the indicator body a Loosen the screw and remove B Lift the spindle and fit the forked end of the lifting lever the lifting lever to the spindle stop 4 Part Names the appearance of a gage varies with the model
6. rds that take into consideration the actual usage frequency environment and method and perform Regularly check and adjust the reference point when using the gage in a place subject to temperature variation regular maintenance checks on the gage based on these standards f This spacer is there to aid the movement of the lifting lever and should not be removed Mitutoyo does not guarantee the performance of this gage if repair or disassembly has been performed by other than Mitutoyo Mitutoyo
7. reference surface is stable Code No individual indicator ACCUracy Indicate Graduation Point Diameter Flatness Stroke Remarks e Dial type gage Adjust the long hand so that it points to the zero graduation mark by rotating the bezel 7050 ae p m 15 um 2046S 0 01 mm S carde 440 mm 3 um 20 mm ng e e Digital type gage Press the ZERO ABS button This is useful when the master gage is set as the reference surface because the measurement contact poini H C 6 20 mm ein With T value can be automatically read by using the PRESET function See the Digimatic Indicator User s Manual for details of the 7051 0 to 10 mm 15 um 20169 oot mm contact point gomm 3 um 20 mm Frame Type A PRESET function 7052 0 to 35 mm 15 um 2046SLB 0 01 mm S carbide 440 mm 3 um 20 mm With lifting lever Use the lifting lever and release again to check that the reference point has not shifted 0 to 10 mm contact point Frame Type B x 16 30 nm S carbide With lifting lever 4 Measure the workpiece es 0 to 1 mm 5 ym 2109SLB 10 0 001 mm contact point p40 mm 3 um 20 mm Frame Type B Use the lifting lever or release to slowly bring the contact point into contact with the workpiece 7056 0 to 1 002 2416S 001 S48 carbide 1 57 DIA 3 um 8 20 mm With lifting lever Repeat this several times and read the value after checking that the graduation value is stable a ne See sae contact point Err T Type A NOTE If a master gage was used to set zero the me
8. tolerance range by determining whether the long hand points within the allowable g80 Large measuring table No 902190 g50 Ceramic measuring table No 903526 Limit hand No 21AAB155 Clamp bracket No 21AAB161 range indicated by the limit hands when the workpiece is measured Be aware of the value indicated by the short hand to Clamp screw No 21AAB162 Except No 7056 No 101214 For No 7056 Clamping plate No21AAB163 avoid misreading one rotation of the long hand e Digital type gage Set the tolerance by using the tolerance setting function Judge whether the workpiece dimensions are within the tolerance range via the symbol that is displayed when the workpiece is measured See the Digimatic Indicator User s Manual for details of the tolerance setting function NOTE Workpieces with a height exceeding the measurement range or a depth exceeding 45 mm cannot be measured Do not apply the load of 30N or more onto the measuring table when the measuring table clamp is tightened The indicator of No 7052 and No 7053 can be moved up and down within a range of 20 mm by adjusting the position of the stem clamp 11 Maintenance and Repairs ance aNd RepalrS 6 Notes on Use IMPORTANT When carrying the gage be sure to hold the frame so that you do not drop the unit IMPORTANT _ Do not suddenly activate the spindle or apply an excessive horizontal load Remove dirt or dust from the sliding surface of the spindle using a dry cloth or a cloth on w