Manual ekgMove - movisens GmbH
Contents
1. 13 Close This application shows information about sensor hardware sensor state and sensor configuration 16 Before you start a measurement please check the charging status of the battery The maximum measurement duration can only be reached when the battery is fully charged To start a measurement do the following steps Step 1 In the sensor manager software click on the Start Recording button in the lower left of the window v You can see the following window Measurement configuration x Measurement duration 13 Days oJ Hours oE Minutes Start time Start measurement immediately Start measurement at the specified time Date 10 09 2012 Time 10 35 Step 2 Please supply the following information into the text fields O Measurement duration The maximum measurement duration depends on the manufacturer configuration of your sensor Start time You can start the measurement immediately or delayed at a specific time If you want to start your measurement delayed please specify date and time The given time should not be more than 2 days from now 3 Start the measurement by clicking the Start button v You can see the following window 17 movisens SensorManager Remove sensor 5 xj The recording was started Please remove the sensor from the USB port o 4 Please follow the instructions and remove the sensor from the cradle v The status LED will flash red once per s
2. Flashing blue fast three times per second The sensor is connected to a PC ora charger The battery is actually being charged The battery is flat sensor will turn off soon Flashing Red fast three times per second An error occurred Please contact the manufacturer No LED active The sensor is inactive Combination of red blinking and green blinking as well as red blinking and blue blinking are possible whit the appropriate combination of the above described meanings The ekgMove sensor features a vibration alarm to signal the beginning and the end of a measurement 11 6 Software Installation This chapter describes how to install and uninstall the software and how to update it Beside this the system requirements are defined A 6 1 System Requirements Before installing the software please check if the following system requirements are fulfilled e PC with Windows XP or higher e Administrator rights during installation e A minimum of 300 MB free space on hard disc The delivered software consists of two programs SensorManager Program to configure the sensor to start a measurement and to download the data from the sensor UnisensViewer Program to view the stored data 6 2 Ins tallir Ng the s sof tware Please ensure that your PC fulfills the requirements described above Step 1 Plug the USB drive into the USB port of your PC The content of the medium will be show
3. Order No Chest Belt Size S 10105 Chest Belt Size M 10103 Chest Belt Size L 10104 Chest Belt Size XL 10106 ae one way TBD Micro USB Cable 30102 Cradle with Micro USB Interface 30105 Bluetooth Dongle 30103 Micro USB Charger for 110 240V 30100 USB Hub 7 Ports 30101 5 Description of the sensor ekgMove can either be used e with a comfortable chest belt with dry electrodes O with two one way electrodes For long term measurements the belt is more comfortable For short term measurements the one way electrodes may be more practical The sensor can be attached to the belt by two press buttons movisens M Ovi S e N c If used with one way electrodes the electrode patch adapter has to be used Included in the delivery you also receive a cradle with a micro USB interface To connect the sensor to a PC you have to separate it from the chest belt or the electrode patch adapter and plug it into the cradle The axes of the integrated acceleration sensor are defined as described in the following figure The ekgMove sensor is equipped with a multi colored LED to show the status of the sensor Status LED Meaning Flashing red once The sensor is active and records data per second Flashing red slowly every two seconds Delayed recording active The sensor is connected to a PC ora Hashlng green charger The battery is fully charged 10 Flashing blue
4. red in the picture oe SN 9 v After connecting the sensor to a USB port the charging process starts immediately During charging the status LED is blinking blue If the sensor is fully charged the LED is blinking green If the sensor is deeply discharged e g after a long period where it was not used it can take up to several minutes until the sensor reacts and can be identified by the computer 7 2 Preparing a measurement Before conducting a measurement please make sure you installed the software as described in chapter 6 1 15 Step 1 Start the movisens SensorManager by selecting Windows Startmenu gt movisens SensorManager gt SensorManager Y SensorManager is now searching for available sensors EA movisens SensorManager 1 5 10079 Searching sensor JE xj Searching sensor Please connect a sensor to the usb port Step 2 Connect the ekgMove sensor with your PC using the cradle v The software will automatically detect the device and open the following window 21x et Physiologische Parameter intelligent messen MOVISEnS Sensor information Sensor type ekgMove acc 64 Hz ecg 256 Hz bpmlist nnList press 8 Hz temp 1 Hz Serial number 00459 Firmware revision 10062 Status Size of recorded Data ok Measuremet Duration 0 seconds Battery status charging 54 Configuration Interval 1 second Duration 10 minutes Start time 10 09 2012 at 11 13
5. e not permitted A 0 2 Disclaimer The material in this manual is for informational purposes only The products it describes are subject to change without prior notice movisens makes no representations or warranties with respect to this manual or with respect to the products described herein movisens shall not be liable for any damages losses costs or expenses direct indirect or incidental consequential or special arising out of or related to the use of this material or the products described herein The activity sensor Move Il is no medical device and is not intended to be used for medical purposes ANNI Trarsamsari c 10 3 Trademar ks Windows and Windows XP are registered trademarks of Microsoft Corporation 29 movisens GmbH Tel 49 721 381344 0 Fax 49 721 381344 90 Fritz Erler Str 1 3 info movisens com 76133 Karlsruhe http www movisens com Germany
6. econd as soon as the measurement has started and data will be recorded If a delayed start was configured the LED flashes red every two seconds until the measurement starts v At the end of the measurement the LED stops flashing 2 If you reconnect the sensor after starting a measurement again with a PC the measurement will be stopped prematurely Activation of recording x A The measurement will be started If you reconnect the sensor to a pc during measurement the measurement will prematurely be terminated to If you connect the sensor to an USB charger the measurement won t be stopped That means you can extend the measurement duration by intermediately charging the sensor during a measurement Step 5 using a ches t Attach the chest belt directly on the skin at ithe level of the sternum at the test person so that the two snap fasteners point forward Adjust the size of the chest belt so that it cannot slip out of position but only so tightly that it can be worn comfortable over longer periods Attach the ekgMove sensor at the two snap fasteners The movisens label on the sensor has to be upright and readable 18 Step 5 using one way electrodes Attach the sensor to the electrode patch adapter Attach two one way electrodes to each side of the electrode patch adapter Attach the sensor to the test person The movisens label on the sensor has to be upright and readable Y Due to the long term electrodes used in the ch
7. ekgMove Mobile ECG and Physical Activity Sensor User Manual movisens movi S e N ot movisens Imprint User manual ekgMove Version 02 04 2014 movisens GmbH Fritz Erler Stra e 1 3 76133 Karlsruhe Telefon 49 721 381344 0 Telefax 49 721 381344 90 Internet www movisens com E Mail support movisens com Copyright movisens GmbH Contents A scscsisscccscsssescosssessinssaveusectcecaseciovnscassdvsasussdsousiesdesusesiouws ceuseesstussansessbassebse 1 2 Scope of application ussessessessessevsressersseerssersserssersserssersssersserssseesseense 3 3 Instructions FOF USE ainia cian 5 4 Scope of delivery and accessories nsserseerssssereseerssersesseresserassssesseesessseensser 7 4 1 Scope of delivery 7 4 2 ACCOSSOMGS PPOPPPPPO_A o5 A REEREEEEEEETEERREELEIVEEREFERRIFFERTE FELFEIFEIFEFFEIENFEIFEFFEFEEFELFER 8 5 Description Of the Sensor mssessesserssrssersseesssersserssersserssersssessserssserssersse 9 6 Software Installation ssesserssersserssersressersessersssrrsossessersssessesserssessssssrsssesser 13 6 1 System Requirements sersseessrssrenevesrnsvessrnsessernseensesseensessernsvessesseessesseensssssenseeser 13 6 2 Installing the software 6 3 Updating the software 6 4 Uninstalling the Software nesesseersersseresserrseresseesseveseresseessersseeessersseesseessersseensee 14 AAA 7 1 Charging the Sensor 7 2 Preparing MEaSUre
8. est belt the maximum signal quality will be reached about 15 minutes after applying the chest belt to the skin Therefore please take care that the chest belt is always attached long enough before the acquisition of relevant data Otherwise strong artifacts can occur in the ECG signal especially under vigorous movements e g while running To improve the signal quality you can moisten the electrode areas with water before you attach the chest belt Correct wearing position of chest belt and sensor Sy 19 20 7 4 Stopping a measurement The measurement will automatically be stopped if the configured measurement duration has passed A running measurement will also be stopped when e The sensor is connect to a PC e The end of the battery run time has been reached N U 1 ad FAA AN AN ata urement d ala Storin 19 me To store recorded measurement data on the PC do the following steps Step 1 Start the SensorManager by selecting Windows Start menu gt movisens SensorManager gt SensorManager Step 2 Remove the ekgMove sensor from the chest belt orthe electrode patch adapter and connect the sensor to the PC using the cradle v After the SensorManager has detected the connected sensor the following windows will be shown 21 i EA movisens SensorManager 1 5 10079 Physiologische Parameter intelligent messen Step 3 Click on Save Data v You will see the following
9. her parameters could be calculated from raw data by movisens 3 Instructions for use eo e ve eo to e ve eo e ekgMove is not a medical device Only use ekgMove for the designated applications Never open ekgMove The battery of the ekgMove may only be changed by manufacturer ekgMove is not waterproof Don t use the sensor in wet environments Only use the ekgMove under the specified conditions To charge the battery of the sensor only use USB standard compatible devices Only use movisens chest belts If ekgMove is used with a chest belt these have to be cleaned regularly If there are any problems by using the sensor chest belt e g pressure marks skin irritations itching redness of skin hypersensitivity or other discomfort please stop using the sensor chest belt immediately 4 Scope of delivery and accessories In this chapter you come to know which parts are within the scope of delivery and what is available as accessories All of these parts could be reordered Please consider the order number in the following paragraph To use the sensor a computer is needed in addition to the scope of delivery 4 1 Scope of delivery The following components are included in delivery Article Order No ECG and Activity Sensor ekgMove Cradle with Micro USB Interface Mirco USB Cable SensorManager Software 10101 The following accessories are available Article
10. iological parameters in everyday life Please read this manual completely and thoroughly before bringing the measurement system into service In his manual you will find all Information relevant to the use and maintenance of the measurement system as well as for solving problems If you have any further questions don t hesitate to call us It is our pleasure to help you Phone 49 721 381344 0 2 Scope of application ekgMove is a scientific research instrument to capture the ECG and the physical activity of a person and other secondary parameters derivable from these measurement signals ekgMove is designed and tailored for the use in research applications The ECG and activity sensor ekgMove is not a medical device The sensor acquires a single channel ECG signal It can be used with a chest belt with dry electrodes or with one way electrodes In addition to this the sensor is measuring acceleration in three dimensions air pressure and ambient temperature The configuration of the sensor is done from PC by means ofthe software included in this package ekgMove allows the measurement and in conjunction with movisens DataAnalyzer the analysis of the following parameters Electrocardiogram Acceleration in three dimensions Air pressure and temperature O Heart rate and heart rate variability Movement Acceleration and Step Count Activity Classes and Body Position e Energy Expenditure Tip On demand ot
11. ment ssessessessrssessesssssssnssnssessnssensensensensensessensensenensenseneen 15 73 Starting a measurement usrserssersersserssrsssrvsrrsessrrnersserserssersersserssenserssesnerssesnseener 17 74 Stopping a measurement sersseaserssrensrassensrrssensrrsersseesersseessesseessesseessesseesseessesne 21 7 5 Storing measurement data m neressevssersseressersseressressevessresseessersseressersserssseessersseer 21 7 6 Viewing measurement data isseneresseesserssseesserssersseeessersseresseessersseresserssersseeesee 24 8 Maintenance and proper disposal cssscrrscresicescessoe 25 81 VEE CR iiseeosrressssoosssssods ssi iitstssiissssiss oss visar 25 8 2 Cleaning instructions nesrseresserssersssressersseresseesseveseresseessevsseeessersseresseessersseresssensernr 25 8 3 Cleaning the chest belt ssseraseressersseresseessevsseresseessersseressersserssseersersserssseessernn 25 8 4 Proper disposal 9 Technical Data sseseserseernsserseverssvevevseneversevensseesevsrsevsssnensensssenssessenersevenssnsenes 27 10 Legal Notes 10 1 Copyright near rien 10 2 Disclaimer 10 3 Trademarks mrssssersersesssssersessessessersessessessessessersessessessessessessrsssssssersersersersersene 1 Welcome Dear customer Thank you for choosing the ECG and Activity Sensor ekgMove from movisens With this sensor you get the newest technology for mobile monitoring of psycho phys
12. n If the window does not open automatically select the appropriate drive from the window My computer 13 Double click the file movisens SensorManager Setup Full exe v The Installation runs automatically in the background After successfull installation shortcuts are created in the Windows Start Menu under the entry movisens SensorManager Double click the file UnisensViewer Setup Full exe v The Installation runs automatically in the background After successfull installation a shortcut UnisensViewer is created in the Windows Start Menu You need an internet connection to make an update Select Windows Start Menu gt movisens SensorManager gt Updater and respectively Windows Start Menu gt UnisensViewer gt Updater If anew version is available it will be downloaded and installed automatically The software can be uninstalled using the Windows Control Panel 14 7 Handling This chapter describes how to prepare a measurement and how to attach the sensor to a test person Furthermore you get information to save delete and analyze data from the sensor m 1 CA BE the sensor 71 Char 7 1 Chat ging Step 1 Connect the cradle with the USB cable to a USB port USB port of your computer or another port that conforms to USB standard like USB hub or USB charger Attach the sensor with the help of the push buttons at the cradle Please make sure that the 4 contacts are connected marked
13. o your measurements folder and then open the folder with the desired ID Then double click on the unisens xml file The measurement will then be shown in the UnisensViewer Ansicht Plugins ille 10 Sekunden Tag Auswahl t pe Y Kompression r Minute Woche s Physkakschen Wert runden Stunde Alles Nach Einheiten Sample Point Alle Datei gruppiert and Hold Y Fadenkreuz schlie en analysieren Code w XML Validation L 4 movisens also offers analyzing your data and generating reports according to your needs as a service If you have any further questions please do not hesitate to contact us 24 8 Maintenance and proper disposal 8 1 Maintenance Besides charging the batteries the ecgMove sensor does not need any further maintenance The battery capacity will decrease slowly with charging cycles and age The battery can only be changed by movisens Please contact us in the case when a replacement is necessary 8 2 Cleaning instructions If you want to clean the ekgMove sensor please note the following e Disconnect the sensor from chest belt electrode patch adapter or cradle e Usea soft slightly moistened cloth Take care that no humidity enters the sensor housing 8 3 Cleaning the chest belt If you want to clean the chest belt please consider the following e Wash the chest belt by hand and not in the washing machine e Usea liquid mild detergent e Directly after washing dry the chest belt at the ai
14. r before storing or using it for new measurements 25 The Move Il is subject to the EU directive WEEE Waste Electrical and Electronic Equipment Please consider your local regulations for waste disposal 26 9 Technical Data Power supply Lithium lon battery Supply voltage 3v Battery voltage 2 7 4 2V Number of charging cycles 300 with 1C 1C gt 80 Maximum recording capacity At least 2 weeks depending on firmware configuration Battery run time recording Bluetooth off 2 days Size of sensor WxHxD Internal sensors 62 3mm x 38 6mm x 10 5mm ECG Amplifier Resolution 12bit Input range CM 560mV DM 5mV Gain 227 3db bandwidth 1 6 to 33Hz Output rate 256Hz to 1024Hz 3D acceleration sensor Measurement range 8 g Noise 4 mg Output rate 64 Hz Pressure sensor Measurement range 300 1100 hPa Noise 0 03 hPa Output rate 1 Hz LED 3 color operation and charging status Indicators ani Vibrating alert start and end of measurement Interfaces Micro USB Bluetooth 27 Environmental conditions 28 Temperature 20 C to 60 C 0 C to 45 C during charging Humidity 0 to 75 RH relative humidity Atmospheric pressure 300 to 1100 hPa absolute 10 Legal Notes 10 1 Copyright The software that comes with the Move 3 sensor is protected by copyright Renting exchanging broadcasting duplication or copies ar
15. window or 00459 x Measurements 012 07 23 14 58 00 IDO1 22 Step 4 Please type in the following information e Select the base folder where your measurements should be stored To do this click the button after the text field e Type in the ID of the measurement If you want to use date and time in the ID click the button after the text input field e Allother information is optional If the measurement data shall be further processed with the movisens DataAnalyzer the additional information is mandatory Step 5 Finally click on Save data The measurement data will be stored in the Unisens format Unisens is an open data format for multi sensor data You can find further information about Unisens here www unisens org v The software confirms the end of data storing process The following window is shown x J How do you want to continue Open destination folder Show data Analyze data You can now directly show the stored data The measurement will be opened in the UnisensViewer If you have installed the movisens DataAnalyzer you can directly start data analysis and generate reports be clicking on Analyze data You can find more information in the DataAnalyzer manual 23 76 Viewing measurement data To view recorded measurements click on Show data directly after the string process To view previously stored measurements use the Windows Explorer to navigate t