1. To reference Technical Advisories and Product Release Notes go to Canoga Perkins website http www canoga com CAUTION This product may contain a laser diode operating at a wavelength of 1300 nm 1600 nm Use of optical instruments e g collimating optics with this product may increase eye hazard Use of controls or adjustments or performing procedures other than those specified herein may result in hazardous radiation exposure Under normal conditions the radiation levels emitted by this product are under Class 1 limits in 21 CFR Chapter 1 Subchapter J ATTENCION Cet quipement peut avoir une diode laser mettant des longueurs d onde allant de 1300nm 1600nm L utilisation d instruments optiques par exemple un collimateur optique avec cet quipement peut s av rer dangereuse pour les yeux Proc der des contr les des ajustements ou toute proc dure autre que celles d crites ci apr s peut provoquer une exposition dangereuse des radiations Sous des conditions normales le niveau des radiations mises par cet quipement est en dessous des limites prescrites dans CFR21 chapitre 1 sous chapitre J NOTICE This device contains static sensitive components It should be handled only with proper ElectroStatic Discharge ESD grounding procedures NOTE Cet quipement contient des composants sensibles aux d charges lectro statiques Il doit absolument tre manipul en respectant les r gle
2. both DC sources to the same ground e For a DC supply loosen the screws for the GND and VDC terminals on the front panel then slide the wires under the square washers and tighten the screws See Figure 1 Check the polarity and use an ohmmeter to verify that 48 VDC is not shorted to GND Replace the shield over the terminals on the front panel and connect the power cables to the power source Note The connector for the ESD grounding strap on the front of each power supply connects to 10 11 12 13 Earth ground through the chassis Insert the CIM in slot 0 and tighten the captive screw see Figure 1 For details about connecting the cables for the alarm relays or the chassis link in the domain see the Model 1202 Chassis Interconnect Module User Manual If you have an optional DMM insert it in an unused slot slot 1 is recommended and tighten the captive screw see Figure 1 Insert the remaining modules into the chassis for details see the user manual for each module Install a cover on each unused slot Turn on the chassis power supply s All LEDs on all modules light amber during the power on sequence then the PWR LED lights green To configure each module in the chassis see the user manual for that module UCS 1002 User Manual 2 3 2 4 Blank EdgeAccess Universal Chassis System Chapter 3 Specifications Physical Specifications Chassis dimensions Power supply dimensions Chassis weight unpopul
3. equipment 3 To connect or isolate the Signal and Chassis grounds check the location of the lug installed between the backplane connectors for the power supplies between slots 14 and 15 See Figure 2 Caution To avoid breaking the shorting lug screw it in only finger tight e To isolate the signal and chassis grounds screw the lug into the hole with the round pad labeled CH_GND SIG_GND ISOLATED This is the factory default e To connect the signal and chassis grounds screw the lug into the hole with the square pad labeled CH_GND SIG_GND CONNECTED UCS 1002 User Manual 2 1 2 4 Blank EdgeAccess Universal Chassis System Figure 2 Chassis Backplane With CID Switch and Ground Options at Slots 14 and 15 4 Determine the number for this chassis within the domain then locate the DIP switch inside the chassis on the backplane between the power supply connectors see Figure 2 Check that the power is off then use a non conductive device to set the switches CIDO CID1 and CID2 according to the data in Table 1 The remaining switch is reserved Table 1 Chassis ID Switch Settings Chassis ID Number CIDO CIDI CID2 1 Closed Closed Closed Open Closed Closed Closed Open Closed Open Open Closed Closed Closed Open Open Closed Open Closed Open Open oo L IDAJ Jn IS ND Open Open Open 5 Plug the wire from Earth Ground into the lug on the back of the chassis this connects the chassis to Earth Ground 6 Mount the chassi
4. 0 T D O O lt D O LLI CANOGA PERKINS Universal Chassis System Model UCS 1002 User Manual NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation operation and or maintenance of Canoga Perkins equipment The drawings specifications and information contained in this document are the property of Canoga Perkins and any unauthorized use or disclosure of such drawings specifications and information is prohibited Canoga Perkins reserves the right to change or update the contents of this manual and to change the specifications of its products at any time without prior notification Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that is accurate with regard to any specification Canoga Perkins Corporation 20600 Prairie Street Chatsworth California 91311 6008 Business Phone 818 718 6300 Monday Friday 7 a m 5 p m Pacific Time FAX 818 718 6312 24 hrs Web Site www canoga com Email fiber canoga com Copyright 2002 2006 Canoga Perkins Corporation All Rights Reserved EdgeAccess Universal Chassis System Model UCS 1002 User Manual Product Number 6913000 Rev G 01 2008 EdgeAccess and Canoga Perkins are registered trademarks of Canoga Perkins Corp
5. ated Power supply weight Power Redundancy AC power supply auto ranging Model 1102 2100 DC power supply Model 1112 2400 DC power supply Model 1112 2401 Environment Operating temperature Humidity Regulatory Compliance 3 47 H x 17 39 W x 10 8 D 88 mm x 442 mm x 274 mm 3 1 H x 1 6 W x 7 875 D 79 mm x 41 mm x 200 mm 11 4 Ibs 5 17 kg 1102 2100 1 50 lbs 0 68 kg 1102 2101 1 34 Ibs 0 61 kg 1112 2400 and 1112 2401 0 66 lbs 0 3 kg Optional AC AC DC DC or AC DC Input 120 W 100 240 VAC 1 25 A 50 to 60 Hz Heat dissipation max 410 BTU hr Output 5 VDC 15 A nominal Input 100 W 36 to 75 VDC 3 0 A max Heat dissipation max 341 BTU hr Output 5 VDC 15 A nominal Input 135 W 36 to 75 VDC 4 0 A max Heat dissipation max 462 BTU hr Output 5 VDC 20 A nominal 0 to 50 C 10 to 95 non condensing e ETL cETL CAN CSA C22 2 No 60950 UL 60950 EN 60950 e EN 60825 1 FCC Part 15B Class A EN 55022 e EN 55024 EN 61000 3 2 EN 61000 3 3 e R amp TTE Directive EN 300 386 e C Tick AS NZS 3548 e NEBS Level 3 e CE Mark UCS 1002 User Manual 3 1 3 2 Blank EdgeAccess Universal Chassis System poet A arranty Information Current Warranty information is available on line in the Client Login Area of the Canoga Perkins web site www canoga com or by contacting Technical Support at 800 360 6642 voice or fiber canoga com email UCS 1002 User Ma
6. ess Universal Chassis System Chapter 2 Installing and Setting Up the Chassis This section describes how to set up and install the chassis Before setting up the chassis make sure these items are available e Chassis with application modules the CIM is required and the DMM is optional e Power cables 14 or 16 gauge wire for DC power e Contact wires for the Alarm Relays optional Caution Equipment intended only for installation in a RESTRICTED ACCESS LOCATION accessible only to electrically skilled persons and electrically instructed persons with the proper authorization Follow these steps to install the chassis 1 Plan the installation considering these characteristics e Place the chassis within 7 ft 2 134 m of the power source e Plan to use one or more of these locations for the connection to Earth Ground e The bonding lug on the rear of the chassis near the bottom e The grounding prong on the AC power cord e The ground of the 48 VDC terminal strip e The mounting hardware for the rack if the rack is tied to Earth Ground e Place the chassis adjacent to other Canoga Perkins or related equipment e Allow room for the cable management bracket s that channel the cables allowing slack in the cables and providing a surface for securing with a tie wrap 2 Unpack the chassis cables and modules and inspect all parts for damage and compare them with the packing list Set the packaging aside in case you need to return the
7. nual A 1 CANOGA PERKINS CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth California 91311 6008 USA Phone 818 718 6300 FAX 818 718 6312 Web Site www canoga com Email fiber canoga com
8. odule User Manual e Domain Management Module DMM optional and recommended in slot 1 provides management for all chassis in the domain through a single IP addressable user interface screen for details see the Model 1502 Domain Management Module User Manual or the Model 1500 Domain Management Module User Manual when the DMM is installed in the UCS 1000 e Application modules located in any slot from 1 through 14 such as fiber optic modems multiplexers or media converters e Power Supply can be one or two AC or DC supplies or an AC supply and a DC supply place the primary supply in slot 15 and the secondary supply in slot 14 Figure 1 UCS 1002 Chassis Power Supplies You can use one or two AC and or DC power supplies in the chassis each power supply uses one slot With one power supply the chassis supports the CIM and up to 14 modules with two power supplies the chassis supports the CIM and up to 13 modules For specifications for the power supplies see Chapter 3 An LED on each power supply lights green when the power is on The chassis is a passive device that does not generate an alarm if the power fails However the CIM includes circuitry and alarm relay contacts that can route the alarm signal to an external device The CIM forwards the power status to the DMM which logs the power failure and sends an alarm trap for details see the user manuals for your CIM and DMM UCS 1002 User Manual 1 1 1 2 Blank EdgeAcc
9. s de mise la terre afin de pr venir de telles d charges EdgeAccess Universal Chassis System Table of Contents Universal Chassis System Model UCS 1002 User Mannal ccsscccsssscssssscsseeees i Chapter 1 OVER VIC Win Tes 1 1 Power SUppli s Erin tient nt ren ne a Met due niet fin tas acid 1 1 Chapter 2 Installing and Setting Up the Chassis 0 0000ss00000s0000000000002000002000000 2 1 Chapter 3 DECITICACIONS ia IRA AA EAS ARAS 3 1 Physical Specifications ie ooer rea eeina EB ERREGER 3 1 Regulatory Compliance cin da ida 3 1 Appendix A Warranty Information esse A 1 List of Figures Figure l UCS 1002 Chassis assiste ase Be ai ma DER Dar E aiik 1 1 Figure 2 Chassis Backplane With CID Switch and Ground Options at Slots 14 and 15 2 2 List of Tables Table 1 Chassis ID Switch Settings sers 2 2 UCS 1002 User Manual i ii Blank EdgeAccess Universal Chassis System Chapter 1 Overview The Model 1002 Universal Chassis System UCS Chassis houses and supplies power to Canoga Perkins modules that are 2U high The UCS 1002 can be part of a managed domain of up to eight chassis these can be a mix of UCS 1000 and UCS 1002 Figure 1 shows the UCS 1002 with these components e Chassis Interconnect Module CIM required in slot 0 provides alarm relays connection to other chassis in the domain and management through the chassis backplane for details see the Model 1202 Chassis Interconnect M
10. s in a standard 19 inch relay rack in a 23 inch rack or on a table top The chassis ships with mounting brackets preconfigured for flush mounting in a standard 19 inch relay rack you can reposition the brackets as needed e Fora 19 inch rack position the chassis in the rack and secure the brackets to the rack with four screws See Figure 1 e For a 23 inch rack remove the mounting screws for the 19 inch mounting brackets and secure the optional 23 inch mounting bracket with the screws then position the chassis in the rack and secure the brackets to the rack with screws e Fora tabletop select a flat surface in a secure location turn the chassis up side down and attach the self adhesive feet near the four corners of the chassis then turn the chassis right side up and place it on the flat surface 2 2 UCS 1002 User Manual EdgeAccess Universal Chassis System Install the power supply s Always place the primary power supply in slot 15 If you have a secondary power supply place it in slot 14 See Figure 1 To install the power supply s follow these steps a Unplug the power cables or cord and turn the power switch off b Insert the power supply firmly into its slot then secure the screws e Foran AC supply plug the power cord into the front panel then plug the cord into the power source Caution To prevent damage to the power supply or power source do not reverse polarity and if you use two DC power supplies connect