Home
Manual - Microh
Contents
1. er Senn 8 8 6 CLEANING AND MAINTENANCE Caution DANGER TO LIFE Disconnect from mains before starting maintenance operation The operator has to make sure that safety relating and machine technical installations are inspected by an expert after every four years in the course of an acceptance test The operator has to make sure that safety relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device must be tightly connected 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The electric power cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Replacing the fuse If the fine wire fuse of the device fuses only replace the fuse by a fuse of same type and rating Before replacing the fuse unplug mains lead Procedure Step 1 Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing anticlockwise Step 2 Remove the old fuse from the fuseholder Step 3 Install the new fuse in the fuseholder Step 4 Repla
2. 100 119 RED 0 100 GREEN 0 BLUE 100 120 139 RED 100 GREEN 0 BLUE 100 0 140 159 RED 100 GREEN 0 100 BLUE 0 100 160 179 RED 100 0 GREEN 100 0 BLUE 100 180 199 RED 100 GREEN 100 BLUE 100 200 204 White Color Temprature 1 WARM 205 209 White Color Temprature 2 210 214 White Color Temprature 3 215 219 White Color Temprature 4 220 224 White Color Temprature 5 225 229 White Color Temprature 6 230 234 White Color Temprature 7 235 239 White Color Temprature 8 240 244 White Color Temprature 9 245 249 White Color Temprature 10 250 255 White Color Temprature 11 COQL 000 009 No function 010 023 Auto Program PR 01 RGB colors switching 024 038 Auto Program PR 02 7 colors switching 039 053 Auto Program PR 03 R G B colors fading 054 068 Auto Program PR 04 7 colors Fading 069 083 Auto Program PR 05 Color Macros Fading 084 098 Auto Program PR 06 Chase 1 099 113 Auto Program PR 07 Chase 2 7 114 128 Auto Program PR 08 Chase 3 129 143 Auto Program PR 09 Chase 4 144 158 Auto Program PR 10 Chase 5 159 173 Auto Program PR 11 Chase 6 174 188 Auto Program PR 12 Chase 7 189 203 Auto Program PR 13 Chase 8 204 218 Auto Program PR 14 Chase 9 219 233 Auto Program PR 15 Loop above Pro 01 Pr 14 234 255 Sound active 8 000 255 Speed of Auto Programs Slow Fast 000 009 Default dimmer speed 010 048 Line
3. 41 000 255 Green 0 100 LED 14 42 000 255 Blue 0 100 43 000 255 Red 0 100 44 000 255 Green 0 100 LED 15 45 000 255 Blue 0 100 46 000 255 Red 0 100 47 000 255 Green 0 100 LED 16 48 000 255 Blue 0 100 53 Channels Mode CHANNEL VALUE 000 255 FUNCTION Red 0 100 LED 1 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 Red 0 100 5 000 255 Green 0 100 LED 2 6 000 255 Blue 0 100 7 000 255 Red 0 100 8 000 255 Green 0 100 LED 3 9 000 255 Blue 0 100 10 000 255 Red 0 100 11 000 255 Green 0 100 LED 4 12 000 255 Blue 0 100 13 000 255 Red 0 100 14 000 255 Green 0 100 LED 5 15 000 255 Blue 0 100 16 000 255 Red 0 100 17 000 255 Green 0 100 LED 6 18 000 255 Blue 0 100 19 000 255 Red 0 100 20 000 255 Green 0 100 LED 7 21 000 255 Blue 0 100 22 000 255 Red 0 100 23 000 255 Green 0 100 LED 8 24 000 255 Blue 0 100 25 000 255 Red 0 100 26 000 255 Green 0 100 LED 9 27 000 255 Blue 0 100 28 000 255 Red 0 100 4 29 000 255 Green 0 100 LED 10 30 000 255 Blue 0 100 31 000 255 Red 0 100 32 000 255 Green 0 100 LED 11 33 000 255 Blue 0 100 34 000 255 Red 0 100 35 000 255 Green 0 100 LED 12 36 000 255 Blue 0 100 37
4. 1 CH 32 function as following 1 000 255 Warm white 0 100 HER 2 000 255 Cool white 0 100 3 000 255 Warm white 0 100 LED 2 4 000 255 Cool white 0 100 5 000 255 Warm white 0 100 LED 3 6 000 255 Cool white 0 100 7 000 255 Warm white 0 100 LED 4 8 000 255 Cool white 0 100 9 000 255 Warm white 0 100 LED 5 10 000 255 Cool white 0 100 11 000 255 Warm white 0 100 LED 6 12 000 255 Cool white 0 100 13 000 255 Warm white 0 100 LED 7 14 000 255 Cool white 0 100 15 000 255 Warm white 0 100 LED 8 16 000 255 Cool white 0 100 17 000 255 Warm white 0 100 LED 9 18 000 255 Cool white 0 100 19 000 255 Warm white 0 100 LED 10 20 000 255 Cool white 0 100 21 000 255 Warm white 0 100 LED 11 22 000 255 Cool white 0 100 23 000 255 Warm white 0 100 LED 12 24 000 255 Cool white 0 100 25 000 255 Warm white 0 100 LED 13 26 000 255 Cool white 0 100 27 000 255 Warm white 0 100 LED 14 28 000 255 Cool white 0 100 29 000 255 Warm white 0 100 LED 15 30 000 255 Cool white 0 100 31 000 255 Warm white 0 100 LED 16 32 000 255 Cool white 0 100 LED ARRAY oc g gt gt
5. 000 255 Red 0 100 38 000 255 Green 0 100 LED 13 39 000 255 Blue 0 100 40 000 255 Red 0 100 41 000 255 Green 0 100 LED 14 42 000 255 Blue 0 100 43 000 255 Red 0 100 44 000 255 Green 0 100 LED 15 45 000 255 Blue 0 100 46 000 255 Red 0 100 LED 16 47 000 255 Green 0 100 48 000 255 Blue 0 100 49 000 255 Master Dimmer 0 100 000 009 No function a 010 255 Strobe Slow Fast 1 30Hz 000 009 No function 010 023 Auto Program PR 01 RGB colors switching 024 038 Auto Program PR 02 7 colors switching 039 053 Auto Program PR 03 R G B colors fading 054 068 Auto Program PR 04 7 colors Fading 069 083 Auto Program PR 05 Color Macros Fading 084 098 Auto Program PR 06 Chase 1 099 113 Auto Program PR 07 Chase 2 51 114 128 Auto Program PR 08 Chase 3 129 143 Auto Program PR 09 Chase 4 144 158 Auto Program PR 10 Chase 5 159 173 Auto Program PR 11 Chase 6 174 188 Auto Program PR 12 Chase 7 189 203 Auto Program PR 13 Chase 8 204 218 Auto Program PR 14 Chase 9 219 233 Auto Program PR 15 Loop above Pro 01 Pr 14 234 255 Sound active 52 0000 255 Speed of Auto Programs Slow Fast 000 009 Default dimmer speed 010 048 Linear dimmer 049 088 Non linear dimmer 1 53 089 128 Non linear dimmer 2 129 168 Non linear dimmer 3 169 208 WW CW Mode ON 209 255 WW CW Mode OFF When CH 53 169 208 WW CW ON CH
6. MICROF LED NOVA 16 USER MANUAL For safety please read this user manual carefully before initially use Package Included LED NOVA 16 User Manual Power Input Cord 5mm Allen Key Safety Instructions Do not open this device there is no user serviceable parts inside e DO not look at the light source when the device is on e CAUTION This unit s housing may be hot when lights are operating e Install this device in a location with adequate ventilation at least 20 inch 50 cm from adjacent surfaces Do not leave any flammable material within 50 cm of this unit while operating or connected to power e Use a safety rope when mounting this device overhead e Do not hang units using only the coffin locks e Do not operate this device outdoors or in any location where dust excessive heat water or humidity may affect it e Do not operate this device if the housing lenses or cables appear damaged e Do not connect this device to a dimmer or rheostat ONLY connect this device to a grounded and protected circuit ONLY use the hanging bracket to carry this device e In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this device at higher temperatures Power Input amp Power Linking This device has an auto switching power supply work with input voltage range of 100 240 VAC 50 60 Hz Link up to the maximum 4 devices at 120 VAC or 8
7. ar dimmer 049 088 Non linear dimmer 1 9 089 128 Non linear dimmer 2 129 168 Non linear dimmer 3 169 208 WW CW Mode ON 209 255 WW CW Mode OFF 48 Channels Mode CHANNEL VALUE FUNCTION 1 000 255 Red 0 100 2 000 255 Green 0 100 LED 1 3 000 255 Blue 0 100 4 000 255 Red 0 100 5 000 255 Green 0 100 LED 2 6 000 255 Blue 0 100 7 000 255 Red 0 100 8 000 255 Green 0 100 LED 3 9 000 255 Blue 0 100 10 000 255 Red 0 100 11 000 255 Green 0 100 LED 4 12 000 255 Blue 0 100 13 000 255 Red 0 100 14 000 255 Green 0 100 LED 5 15 000 255 Blue 0 100 16 000 255 Red 0 100 17 000 255 Green 0 100 LED 6 18 000 255 Blue 0 100 19 000 255 Red 0 100 20 000 255 Green 0 100 LED 7 21 000 255 Blue 0 100 22 000 255 Red 0 100 23 000 255 Green 0 100 LED 8 24 000 255 Blue 0 100 25 000 255 Red 0 100 26 000 255 Green 0 100 LED 9 27 000 255 Blue 0 100 A 28 000 255 Red 0 100 29 000 255 Green 0 100 LED 10 30 000 255 Blue 0 100 31 000 255 Red 0 100 32 000 255 Green 0 100 LED 11 33 000 255 Blue 0 100 34 000 255 Red 0 100 35 000 255 Green 0 100 LED 12 36 000 255 Blue 0 100 37 000 255 Red 0 100 38 000 255 Green 0 100 LED 13 39 000 255 Blue 0 100 40 000 255 Red 0 100
8. at 230 VAC DO NOT exceed this number DMX Linking amp Connection This device can work with a DMX controller using a regular DMX serial connection This device uses a regular DMX protocol for its DMX modes 3 5 9 48 and 53 channels Art Net Connection Art Net is an Ethernet protocol that uses TCP IP to transfer large amounts of DMX512 data over a large network Art Net uses the EtherCon RJ 45 connection Art Net is Designed by and Copyright Artistic Licence Holdings Ltd 1 Disconnect the DMX controller from this device 2 Use RJ45 cables connect this device to your computer 3 You can link the other these devices with RJ45 cables or regular DMX cables 4 You can use the Art Net software to control and programming these devices Your computer needs the relevant software of Art Net protocol Cooling Fans This device has cooling fans controled by temperature sensor When the device temperature inside reach about 60 C the fans start working from a slow speed to fast as the temperature increasing Mounting This device can be mounted in many orientation provided each individual device is secured through the mounting bracket The coffin locks are for device alignment only and are not weight bearing DO NOT hang device using only the coffin locks Use a safety rope when mounting this device overhead Mounting Diagram CONTROL BOARD OPERATION Press the Menu until one of the following displayed Di
9. ce the fuseholder in the housing and fix it TECHNICAL SPECIFICATIONS Power supply 100 240 V AC 50 60 Hz Power consumption 390 W DMX control channels 3 5 9 48 or 53 chs DMX512 connection 3 pin XLR 5 pin XLR Sound control via built in microphone LED type 30 W COB Tri color RGB Number of LEDs 16 Beam angle 30 Dimensions LxWxH 425 x 425 x 141 mm Weight 11 3 kg Maximum ambient temperature Ta 40 Maximum housing temperature TC steady state 80 C Min distance from flammable surfaces 0 5 m Min distance to lighted object 0 1 m Fuse T 3 15A 250V
10. nter see following graphic Mode Value Function Static color lt R gt Red Static color lt G gt Green Static color lt B gt Blue Static Color Static color lt RG gt Red Green Static color lt BG gt Green Blue Static color lt RB gt Red Blue Static color lt RGB gt Red Green Blue User Mode This mode allows the user set intensity of R G B separately to get endless color mixing from the control board without DMX controller to set the device to run strobe desired Entered user mode Manual color use lt UP gt and lt DOWNs gt to select the R G B for Colors intensity or S for strobe Use lt UP gt and lt DOWNs gt to set the colors intensity values 0 255 or Strobe speed values 000 100 Freeze Slow Fast then press Enter to confirm Automatic Mode This fixture has a built in automatic program Entered Auto Program mode use lt UP gt and lt DOW N gt to select the built in programs Pr01 Pr 12 then press the Enter to confirm Use lt UP gt and lt DOWNs gt to select the operating speed of the program Value Speed 000 Speed100 Freeze Slow Fast press Enter to confirm Mode Value Function Auto program Pr 01 RGB colors switching Auto program Pr 02 7 colors switching Auto program Pr 03 R G B colors fading Auto program Pr 04 7 colors Fading Auto program Pr 05 Color Macros Fading Auto program P
11. r 06 Chase 1 ce Auto program Pr 07 Chase 2 Piani Auto program Pr 08 Chase 3 Auto program Pr 09 Chase 4 Auto program Pr 10 Chase 5 Auto program Pr 11 Chase 6 Auto program Pr 12 Chase 7 Auto program Pr 13 Chase 8 Auto program Pr 14 Chase 9 Auto program Pr 15 Loop above Pro 01 Pr 14 Master Slave Operation This mode allows for multiple units slave fixtures to follow a single master fixture 1 Set the master fixture to one of the standalone operating modes automatic sound user mode or static color modes 2 For slave units entered the Master Slave mode select Slave press Enter DMX VALUES 3 Channels Mode CHANNEL VALUE FUNCTION 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 5 Channels Mode CHANNEL VALUE FUNCTION 1 000 255 Red 0 100 2 000 255 Green 0 100 3 000 255 Blue 0 100 4 000 255 Master Dimmer 0 100 000 009 No function i 010 255 Strobe Slow Fast 1 30Hz 9 Channels Mode CHANNEL VALUE FUNCTION Red 0 100 000 255 000 255 Green 0 100 000 255 Blue 0 100 4 000 255 Master Dimmer 0 100 000 009 No function j 010 255 Strobe Slow Fast 1 30Hz 000 019 No Function 020 039 RED 100 GREEN 0 100 BLUE 0 040 059 RED 100 0 GREEN 100 BLUE 0 060 079 RED 0 GREEN 100 BLUE 0 100 080 099 RED 0 GREEN 100 0 BLUE 100
12. splay Function 1 DMX Address To set DMX address 2 DMX Channel 3 Dimmer Curve 4 Sound Mode To set DMX channel modes CH 03 CH 05 CH 09 CH48 CH53 To set dimmer speeds 01 02 03 04 To set sound active mode and the sensitivity Speed 000 Speed 100 5 Static Color To set static colors Static Color R G B GB RG RB RGB 6 Manual Color To set user mode intensity of R G B separately for color mixing and strobe rate 7 Auto Program To set built in automatic programs Pr 01 Pr 15 and speeds 000 100 8 Master Slave To set Master Slave modes Use Up and Down button to select your desired operation then press Enter to confirm DMX Addressing After select the DMX Address and press Enter then use Up and Down to set the desired DMX address 001 512 press Enter again to confirm DMX Modes After select the DMX Channel and press Enter then use Up and Down to set the desired DMX mode 03 05 09 48 53 press Enter again to confirm Dimmer Speed Setting After select the Dimmer Curve and press Enter then use Up and Down to set the desired dimmer speed 01 02 03 04 press Enter again to confirm Sound Mode Entered Sound mode use lt UP gt and lt DOWNs to set the sensitivity Sen 000 Sen 100 press Enter to confirm Setting Static Colors Entered Static Color you can select the desired solid color via the UP or DOW N buttons and confirm by E