Home

SL3000UL8 Owner`s Manual

image

Contents

1. SPECIFICATIONS AND WARNINGS REQUIRED ENTRAPMENT PROTECTION DEVICE LOCATIONS AWARNING To prevent SERIOUS INJURY or DEATH from a moving gate Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate Locate entrapment protection devices to protect in BOTH the open and close gate cycles Locate entrapment protection devices to protect between moving gate and RIGID objects such as posts or walls Non Contact Sensors Photoelectric Sensors Install photoelectric sensors to protect against any entrapment or safety conditions encountered in your gate application See Entrapment Protection Devices Safety loops allow the gate to stay open when vehicles are obstructing the gate path Suggested for vehicles 14 feet or longer See Loop Detector Wiring Gate Rail Stops For safety reasons physical stops MUST be installed on both ends of the gate rail prior to installation of the gate operator This will assure that the gate does not derail while opening or closing fully SPECIFICATIONS AND WARNINGS REQUIRED ENTRAPMENT PROTECTION DEVICE LOCATIONS AWARNING To prevent SERIOUS INJURY or DEATH from a moving gate Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate e Locate entrapment protection devices to protect in BOTH the open and close gate cycles e Locate entrapment protection devices to
2. 12 CHAIN DISTANCE AND HEIGHT ON GATE 12 CONTROL BOARD DESCRIPTION 13 SURGE SUPPRESSOR TERMINAL CONNECTIONS 14 WIRING 15 EARTH GROUND ROD INSTALLATION 15 120 VAC POWER CONNECTION 16 HEATER POWER CONNECTION 16 LINKING PRIMARY SECONDARY OPERATORS 17 SOLENOID MAGLOCK RELAY CONNECTION 18 FACTORY INSTALLED DC2000 CONNECTION 19 DC2000 DEVICE WIRING 20 PLUG IN LOOP DETECTOR WIRING 21 120 VAC EXTERNAL LOOP DETECTOR WIRING 22 ENTRAPMENT PROTECTION DEVICES 23 ENTRAPMENT PROTECTION DEVICES 24 OMNICONTROL BOARD CONNECTIONS 25 ADJUSTMENTS 26 SET GATE OPENING DIRECTION 26 LIMIT SWITCH 26 RADIO RECEIVER PROGRAMMING 27 SETTING TIMER ON OFF 222222525 rrr m 28 ADJUSTING REVERSING SENSOR S 29 MAINTENANCE AND OPERATION 30 MAINTENANGE etre bi Dr oder med 30 BUILT IN SWITGH fasse e RR eR 31 AUDIO ALARM ar ensuite ones ts 31 MANUAL DISCONNECT 32 OPTIONAL MANUAL
3. White Neutral Green Ground Black 120Vac Red OmniControl Board 8 21 H H 0 0 ry ry N SN Input Power 3 120Vac 60 Hz Grounded H 2 Ii zl ira z 8 I e le 7 gt lt amis i a ew o arg E MS LINK SYSTEM ON TIMER Y 4 a0 35 vj 25 LOFF memo Black 120Vac af HBH 3 on E White Neutral 5 54 7 m Green Ground 28 me stake nai TE i5 5 DEPT OPEN RECEIVER OF Factory Heater 5 p E FE NOTE Wires into 8 C MBA gt 153 main power and draws 3 amps 5 210 J1 1 to J3 3 4 Safety Loo 2 om J1 3 to J3 1 2 Center Loop Not Used S S 4 Black oo 2 J1 5 to J2 3 4 Strike Open Push Button J1 6 to J3 5 6 Exit Loo Reset Switch J1 7 to J2 5 Radio Receiver Neg J1 8 to J2 6 Radio Receiver to 41 9 to J2 1 2 Fire Dept Key Switch M J1 10 to J2 7 Radio Receiver 4 Black Motor 2 White 2 White Motor 0 0 6 1 Red Relay 3 Black Module Optional 1 Red 2 Black UL Alarm NOTE Limit Limit Box switch wiring differs when DC2000 js used 1 Red 0 5 Brown Com 10 Orange 9 Yellow Com 4 Com 2 N O Interlock Assembly Assy NOTE Reset switch and interlock assembly connectio
4. Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed refer to ASTM F2200 for additional gate types Gates shall be designed constructed and installed to not fall over more than 45 degrees from the vertical plane when a gate is detached from the supporting hardware Gates shall have smooth bottom edges with vertical bottom edged protrusions not exceeding 0 50 inches 12 7 mm when other than the exceptions listed in ASTM F2200 The minimum height for barbed tape shall not be less than 8 feet 2 44 m above grade and for barbed wire shall not be less than 6 feet 1 83 m above grade An existing gate latch shall be disabled when a manually operated gate is retrofitted with a powered gate operator A gate latch shall not be installed on an automatically operated gate Protrusions shall not be permitted on any gate refer to ASTM F2200 for Exceptions Gates shall be designed constructed and installed such that their movement shall not be initiated by gravity when an automatic operator is disconnected A pedestrian gate shall not be incorporated into a vehicular gate panel or that portion of the adjacent fence that the gate covers in the open position 2 Specific Applications 2 1 2 2 2 3 Any non automated gate that is to be automated shall be upgraded to conform to the provisions of this specification This specification shall not apply to gates generally used for p
5. opening and closing to reduce the risk of entrapment Swinging gates shall not open into public access areas The gate must be properly installed and work freely in both directions prior to the installation of the gate operator Controls intended for user activation must be located at least six feet 6 away from any moving part of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use The Stop and or Reset if provided separately must be located in the line of sight of the gate Activation of the reset control shall not cause the operator to start A minimum of two 2 WARNING SIGNS shall be installed one on each side of the gate where easily visible For a gate operator utilizing a non contact sensor a Reference owner s manual regarding placement of non contact sensor for each type of application b Care shall be exercised to reduce the risk of nuisance tripping such as when a vehicle trips the sensor while the gate is still moving c One or more non contact sensors shall be located where the risk of entrapment or obstruction exists such as the perimeter reachable by a moving gate or barrier For a gate operator utilizing a contact sensor such as an edge sensor One or more contact sensors shall be located where the risk of entrapment or obstruction exists su
6. 120Vac 60 Hz 2 White Grounded 1 Relay I CaS E 2 White Adapter 3 E 3 Black Module 2 al zs gt gt H Optional amp e 2 1 Red Ne e 3 2 Black UL Alarm IS Limit Box Sus SYSTEM ON rer Assy E 50 OVERLOAD 409 0 z5 95 OFF 2 Black 120Vac 8 E H 3 ig OPEN LEFT OPEN RIGI White Neutral PIE 5 eji i 1 Red Green Ground B Brown Com Factory Heater J HE me NOTE Wires into LOOP LOOP LOOP main power and 4 Com draws 3 amps 2 N O E LING J1 1 to J3 3 4 Safety Loo om cal J13 to J3 1 2 Center Loop Not Used 3 S or 4 Black 5 to J2 3 4 Strike Open Push Button ee Interlock 2 Red J1 6 to J3 5 6 Exit Loo 1 Assembly J1 7 to 42 5 Radio Receiver Neg Reset Switch J1 8 to J2 6 Radio Receiver to J1 9 to J2 1 2 Fire Dept Key Switch OmniControl J1 10 to J2 7 Radio Receiver Board J10 3 to J1 3 A J102toJ12B Surge Suppressor 110110116 Primary Secondary Connectio t Green 0 Chassis Ground Te OmniControl Board Green i er White 2 Black 1 ais Red puon Boar Radio Harness NOTE See table on next page Optional 38 WIRING DIAGRAMS WIRING TABLE SL3000UL1HP87 OmniControl Board J Safety Loop Inpu
7. ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF THIS PRODUCT Some states do not allow the exclusion or limitation of consequential incidental or special damages so the above limitation or exclusion may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state 48 845 Larch Avenue Elmhurst Illinois 60126 1196 01 36718C 2014 LiftMaster All Rights Reserved
8. ARMED M S LINK Q Quick Close Circuit Allows the gate s close cycle to close quicker than the OmniControl timer will allow Refer to the QCC manual for more specific information See Accessories Ground Second Operator Proximity Switch KC 3 Button Station Dry Contact 12 Vdc House Alarm UL NOTE Cut jumper W4 wire ONLY when installing a 3 button station stop button or QCC Relay Contact Rating N 0 5 Amp 125 Vac april 1 Amp 24 Vdc 25 ADJUSTMENTS SET GATE OPENING DIRECTION WARNING To reduce the risk of SERIOUS INJURY or DEATH Disconnect electric power BEFORE performing ANY adjustments LIC ES gt OPEN LEFT OPEN RIGHT OPEN LEFT OPEN RIGHT Open to the LEFT Open to the RIGHT LIMIT SWITCH ADJUSTMENT Each notch on limit nut is an estimated one inch of gate travel Push and hold lock plate to release limit nuts Roll limit nuts to adjust the open and close limit switches 26 ADJUSTMENTS RADIO RECEIVER PROGRAMMING The receiver can be used as a single two or three channel receiver and is compatible with Security 2 0 remote controls ONLY Each channel is compatible with a certain number of remote controls and keypads Refer to the list below e CH1 50 remote controls and
9. Cause Radio receiver s signal is not getting to gate Solution Cycle the power to the radio receiver operator Solution Check wiring between receiver and surge suppressor Probable Cause Remote is not programmed correctly Solution Reprogram remote control see page 27 Probable Cause Remote is not on the same frequency as the radio receiver Solution Verify that remote control frequency is 315 MHz Probable Cause Blown surge suppressor Solution Measure the resistance between pin 12 and 13 on the surge suppressor See page 14 if the circuit closes when the radio receiver is transmitting replace the surge suppressor gt RESETTING MOTOR S NOTE Press firmly to reset thermal breaker button s A long slotted screwdriver may be needed to reach button on upper motor Motor s need resetting when Reset Motor LED light flashes once THEN System ON LED will flash rapidly 42 TROUBLESHOOTING TROUBLESHOOTING CHART Condition Probable Causes Solution Overload LED ON and Power LED OFF Overload LED ON and Power LED ON System On LED Flashing Reverse Sensor LED ON Alarm Sensor LED ON Command Processed LED ON Timer LED Blinking and Command Processed LED Blinking Timer LED Blinking Command Processed LED Blinking and Reverse Sensor LED ON Audio Alarm ON Any Loop LED ON and No vehicle on the sensing area Short circuit at terminals 11 an
10. NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram We recommend that you install an optional reversing edge BEFORE proceeding with the control station installation ALL power wiring should be on a dedicated circuit and well protected The location of the power disconnect should be visible and clearly labeled ALL power and control wiring MUST be run in separate conduit BEFORE installing power wiring or control stations be sure to follow ALL specifications and warnings described below Failure to do so may result in SEVERE INJURY to persons and or damage to operator DO NOT disconnect the built in audio alarm or reset switch 120 Vac Power Wire 1 2 HP and Dual Motor 14 Gauge 250 FT 16 Gauge up to 150 FT 12 Gauge 10 Gauge 650 FT 8 Gauge 1000 FT 4 Gauge 2200 FT 400 FT 1HP up to 75 FT 125 FT 200 FT 325 FT 500 FT 1100 FT All power wiring should be on a dedicated circuit and well protected NOTE Calculated using NEC guidelines Local codes and conditions must be reviewed for suitability of wire installation EARTH GROUND ROD INSTALLATION Proper grounding gives an electrical charge such as from an electrical static discharge or a near lightning strike a path from which to dissipate its energy safely into the earth Without this path the intense energy generated by lightning could be directed towards the gate operator Although nothing c
11. Top View of Gate Incorrect Installation 2 inch wire grid safety screen is missing Chain is mounted too high or x too low on gate Chain is too loose on gate b Operator is mounted too close and not parallel to gate Top View of Gate Over time the gate s chain will stretch out and need to have links removed from it The links can be removed during normal periodic maintenance of the operator 12 INSTALLATION CONTROL BOARD DESCRIPTION Plug In Loop Detectors Surge Suppressor Le a SE obi _ LVI 1 HP Board Maglock Solenoid Relay Module Connection 1 0050 UL Alarm Connection Primary Secondary T Connection W4 Jumper Wire Plug In Loop Wires 1HP Connection Factory installed SL3000UL1HP8 Models J3 Motor Limit Switch Maglock Solenoid Connection DC2000 Back Up Power or Reset Switch Interlock Connection Circuit Board Power LED Operator power OK when ON Overload LED Operator power has overloaded when ON On Board 3 Button Station Close Stop Open commands Timer Timed close Gate Opening Direction Selector Open Left Open Right Gate Locked LED Maglock Solenoid is activated when on Reset Motor LED Cycle operator power when ON Radio Receiver LED Radio transmitter is activated when ON 12 Center Loop LED Center loop detector activated
12. protect between moving gate and RIGID objects such as posts or walls Contact Sensors Edge Sensors Install edge sensors to protect against any entrapment or safety conditions encountered in your gate application See Entrapment Protection Devices Gate Rail Stops For safety reasons physical stops MUST be installed on both ends of the gate rail prior to installation of the gate operator This will assure that the gate does not derail while opening or closing fully Safety loops allows the gate to stay open when vehicles are obstructing the gate path Suggested for vehicles 14 feet or longer See Loop Detector Wiring Edge sensor for open cycle on wall jat Edge sensor for close cycle Edge sensor for close cycle on wall Edge sensor for open cycle on wall Edge sensor for open cycle on gate INSTALLATION INSTALLATION SETUPS Front or Rear Position with Single Operator UL approved catch roller with safety cover 2 inch wire grid safety screen 48 inches high Low Voltage UL approved conduit 224 FS Maximum gate length 37 ft em Maximum gate length with long gate kit 51 ft Concrete Pad Maximum gate weight varies for operators High Voltage UL approved conduit UL approved catch roller with safety cover Rear Position Warning Placard on both sides of gate Idl
13. separate devices wired to the OmniControl board surge suppressor DC 2000 BackUp System Battery Low C GoD e erp Ls Reverse Sensor Charge OK Manual Auto to Pin 3 4 OmniControl Board Sensor Common pm il 1 12Vdc Photoelectric Sensor 1 Open N O 6 12Vdc 4 Photoelectric Sensor Manual Three Button Dry Contact 5 One Button 4 One Button 4 Common Black Com Manual Key Switch Dry Contact Manual One Button Dry Contact 5 Key Switch Interlock 4 Black fim Assembly 2 2 Red 0 Reset Switch 41 TROUBLESHOOTING THE GATE WILL OPERATE WITH REMOTE The radio receiver LED on the control board remains OFF when using the remote control 1 Probable Cause Remote control battery is dead Solution Replace remote control battery 1 Probable Cause Stuck remote control button dU gal The radio receiver has malfunctioned in the Solution Unstick remote control button The radio receiver LED on the control board remains when using the remote control Po Solution Cycle the power to the radio receiver Remote 2 Probable Cause The radio receiver has malfunctioned in the control will need to be reprogrammed see page 27 ON position Probable
14. that the SL3000UL8 is free from defect in materials and or workmanship for a period of 7 year residential 5 year commercial from the date of purchase The proper operation of this product is dependent on your compliance with the instructions regarding installation operation maintenance and testing Failure to comply strictly with those instructions will void this limited warranty in its entirety If during the limited warranty period this product appears to contain a defect covered by this limited warranty call 1 800 528 2806 toll free before dismantling this product Then send this product pre paid and insured to our service center for warranty repair You will be advised of shipping instructions when you call Please include a brief description of the problem and a dated proof of purchase receipt with any product returned for warranty repair Products returned to Seller for warranty repair which upon receipt by Seller are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replaced with new or factory rebuilt parts at Seller s sole option ALL IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE 7 YEAR RESIDENTIAL 5 YEAR COMMERCIAL LIMITED WARRANTY PERIOD SET FORTH ABOVE EXCEPT
15. when ON 13 13 14 15 16 17 18 19 20 21 22 sensor ALARM 009 H G d ABE NGAI a EE ed id D Photoelectric Sensor Connection CLOSE STOP OmniControl Commercial Strike Open LED Strike connected device activated when ON Safety Loop LED Safety loop detector activated when ON Fire Dept LED Key Switch activated when ON Exit Loop LED Exit loop detector activated when ON Command Processed LED Successful command executed Alarm Sensor Limited Adjustment Reverse Sensor Gate hit obstruction when ON System On LED Operator is successfully performing a command J1 Surge Suppressor Data Connection M S Link LED Data being transferred between primary and secondary operators when ON Primary Secondary mim Connection SURGE SUPPRESSOR TERMINAL CONNECTIONS D 5 26 on r 2 ui 2 OPEN LEFT OPEN RIGHT _ OPEN RECEIVER amp Output Power z Ed r3 De Ground QU LiftMaster OmniControl Surge Suppressor A DOOODU 7 8 9 10 STOP OPEN sarerv exr Ca 120Vac Q Power a EAIN Removable Terminals Center ately xit Fire Dep Strife 0 Loop En Lop Key Switc Pus i Bujton 22 CAUTION GROUND To ENSURE proper operation of external devices ENSURE bare wires make good contact ins
16. 2 keypads CH2 20 remote controls and 2 keypads e CH3 20 remote controls and 2 keypads When the channel has reached full capacity for remote controls all LEDs will blink 3 times When the channel has reached full capacity for keypads all LEDs will blink 4 times Additional accessories can be programmed however the newly programmed accessory will replace the first programmed accessory NOTE The receiver will only allow you to program a button on the remote control to one channel at a time For example if the button on the remote control is already programmed to channel 1 and then is programmed to channel 3 the button will be erased from channel 1 and will only work on channel 3 IMPORTANT Remote control is NOT provided Program a Single Button Remote Control 1 Press and release the Learn button for the selected channel on the receiver The corresponding LED will glow steadily for 30 seconds 2 Within 30 seconds press and hold the button on the remote control that you wish to program to the receiver 3 Release the remote control button when the LED on the receiver blinks then turns off Programming is complete Repeat the steps above for each remote control you would like to program Program a 3 Button Remote Control as OPEN CLOSE and STOP NOTE In order for the operator to function with a 3 button remote the OmniControl Board must be installed Connect CH1 to the Open input connect CH2 to the CLOSE input and c
17. B to Second M S Link B Connect Primary M S Link A to Second M S Link A Partial Primary Individual Control In order for the following operation to occur follow the instructions EXAMPLE There is a double gate the entry gate is to be opened with a radio transmitter and the exit gate with a free exit loop Only one safety loop system is to open both gates and a fire department switch should open both gates at the same time 1 Connect the radio receiver to entry gate only 2 Connect the exit loop to exit gate only 3 Connect the safety loop to both entry and exit gates Plug in loop detectors not applicable Observe polarity of voltage 4 Connect the fire department switch to both entry and exit gates Observe polarity of both operators 17 WIRING SOLENOID MAGLOCK RELAY CONNECTION Connection of a solenoid or magnetic lock can be made using the J7 board connector and Optional Relay Adapter Module Solenoid Lock Solenoid Lock To OmniControl Board Common Optional Relay Adapter Module Relay Module LEDs Relay Light On Indicates actuation of OmniControl board Power Light On Indicates power is being received Magnetic Lock Magnetic Lock Ground Plug In Relay Contact Rating 2 125 AC DC Common 2 Amp switching load capability Normally Open Optional Relay Adapter Module Ground 18 WIRING FACTORY INSTALLED DC2000 CO
18. G Plug In Loop Detectors See Accessories CENTER SAFETY EXIT lt NOt USE AAA jus AO WW wA M A zd LiftMaster m is OFF pP Eg 9 RA receiver LOCKED UM ER ERLOAD Litt Master 1 e ovi z 8 a 6 D 4 5 The wire MUST be twisted together 58 Si minimum 6 twists per foot from the Series Connected CAUTION end of the loop to the control board A To AVOID damaging control board disconnect ALL power to operator before installing plug in loop detectors p 0 Use a different frequency for every loop detector installed SSSSSSSSSSSSSssssy em utside Safety Plug In Safety Loop Detector Allows gate to stay open when vehicles are obstructing path CAUTION Suggested for vehicles 14 feet or longer If the Inside and Outside safety loops are connected to the same loop detector They should be series connected to the detector Have the same dimensions NOTE Refer to the plug in loop detector SHE IO same GL WIS US manual for more specific information Example of a inside and outside 2 wire turn loop connected in series See Installing Insulated Loop Wire on next page for more information Plug In Exit Loop Detector Allows gate to automatically open for exiting vehicles Example of a 3 wi
19. Gate Weight 800 105 Maximum Pull 100 Ibs SL3000ULDMH8 Dual Motor Two 1 2 HP Motors 120 Vac 4 7 Amp Heater 3 Amp Maximum Gate Length 37 ft Maximum Gate Weight 800 105 Maximum Pull 100 Ibs SL3000ULDMDCH8 Dual Motor Two 1 2 HP Motors DC2000 120 Vac 4 7 Amp Heater 3 Amp Maximum Gate Length 37 ft Maximum Gate Weight 800 lbs Maximum Pull 100 Ibs SL3000UL1HP8 1 Horse Power Two 1 2 HP Motors 120 Vac 8 4 Amp Maximum Gate Length 37 ft Maximum Gate Weight 2000 Ibs Maximum Pull 180 105 SL3000UL1HPH8 1 Horse Power Two 1 2 HP Motors 120 Vac 8 7 Amp Heater 3 Amp Maximum Gate Length 37 ft Maximum Gate Weight 2000 Ibs Maximum Pull 180 105 Front View Back View 6 DC2000 Back Up All operators come with 2 warning placards and a warranty card Moving Gate Can Cause Serious Injury or Death Front View Heater DC2000 Back Up Dual Motor Only NOTE The 1 HP models cannot have the DC2000 Battery Backup system SPECIFICATIONS AND WARNINGS UL325 MODEL CLASSIFICATIONS SL3000UL8 is intended for use in vehicular slide gate applications Class I Residential vehicular gate operator A vehicular gate operator or system intended for use in a home of one to four single family dwellings or a garage or parking area associated therewith Class Commercial Ge
20. MAX For more information about accessories X Quick Close Circuit QCC www liftmaster com Part OQCCOMNI 3 Button Control Station Part 02 103 OmniControl Board Part OOMNIEXB LiftMaster 12 Vdc Photoelectric Sensor Part AOMRON Stop Button Part AEXITP UL Approved Round Sensing Edge Part G65MGR20x X length 4 5 6 8 ft Heater Kit e g G65MGR206 is 6 ft Part 6651851 Mounting Plate Part MPEL UL Approved Square Sensing Edge Part G65MGS20x X length 4 5 6 8 ft e g G65MGS204 is 4 ft 33 WIRING DIAGRAMS SL3000UL8 eer O 9 EAN 2 7777 25555 Input Power EI 120Vac 60 Hz Grounded 6 Green 4 H 1 Red Relay h mn amp ES olf all 2 White 31 Adapter 8 3 Black 8 Module e zl s H Optional 21 Red B ES 2Black 5 UL Alarm NOTE Limit Limit Box SYSTEM ON switch wiring Assy differs when Ez DC2000 is used Be Black 120Vac White Neutral I 5 Brown Com Green Ground l ed NO Factory Heater a ET 10 orange 10 NOTE Wires into HeT GEL JJ 9 Yellow Com main power and 4 Com draws 3 amps e 22 al lt e 35 oa omn PP Interlock Reset Switch Assembly NOTE Reset switch and in
21. N Connect the black white and ground wire from the heater to the 120 Vac power supply as shown When the heater switch is left in CAUTI 0 N the ON position the heater will turn on and off automatically when needed To reduce the risk of SERIOUS INJURY DO NOT touch the heater when switch is on heater may be hot Green Wires Ground Switch should left in the ON position Green Wire Ground DQ CHASSIS 7 GROUND Green Wire Ground 16 WIRING LINKING PRIMARY SECONDARY OPERATORS Use a 20 amp dedicated power circuit for each operator Never run high voltage and low voltage wires in same conduit Run low voltage 16 18 gauge wire in UL approved conduit to link operators together Primary Board Primar Seen control boards are interchangeable Secondary Board a OS Ey D 9 AZ Use shielded twisted wires for M S link Shield wire MUST be grounded to primary operator SYSTEM on rowe AR so GD rive Surge Suppressor Primary Secondary NOTE To adjust Connection Vf BBBBBB M BBBBBBE timers see page 28 BBBBBH BBBBBBE A Center H A i E mI Loop 8 hi P P Loop Switch Push Button GROUND Jj NOTE Disconnect the second radio receiver when using a Shield Wire Connect Primary M S Link G to Second M S Link G primary secondary setup Connect Primary M S Link
22. NNECTION DC2000 Startup ED 1 Plug in the 12 pin plug into the DC2000 control unit Make LiftMaster sure the System ON and Charge OK LEDs are lit If the Battery Low led comes on the battery needs to charge before it can be used DC 2000 Sree ty cang 0 D 22 009 ote Low Setup 2 Make sure Gate Direction setting on DC2000 is set the l same as the OmniControl board setting See Adjustments M ae 5 4 y Di d 3 Adjust Reverse Sensor setting See Adjustment TER 4 Reversing Sensor s E 120 Vac Power Failure 120 Vac Power On OmniControl Board Malfunction Manual Mode Push and Hold to operate gate Turn the 120 Vac power off then push and Hold to operate gate Auto Mode Gate automatically opens Turn the 120 Vac power off then gate opens automatically NOTE All devices wired to the DC2000 MUST be dedicated to it alone Normal operation will be controlled by separate devices wired to the OmniControl board and surge suppressor EXAMPLE If the DC2000 js automatically opening the gate due to a power failure auto mode any manual command such as One Button Three Push Button Key Switch Photoelectric Sensor or Edge Sensor will cancel the automatic mode of the DC2000 After such cancellation the DC2000 will continue to operate in manual mode until 120 Vac power is restored 19
23. ON Mu Green N C AD 40 409 m 8E QE E eg FIRE 9 RADIO GATE E 5 DEPT OPEN RECEIVER LOCKED 62 6 Brown Com 7 2 9442 D2 Rea n o B 10 Yellow Com B 9 Orange 0 Limit Box Assembly 1 4 2 Blue 02200 r m 4 Yellow es 2 5 Orange 6 Brown 1 r o 7 Black Black Shield i Green N C Purple N C i 4 White 1 Red mom a ARE Red N O J 20 Black Com Interlock Red N O Assembly Black Com Q 4 Black Reset Switch 3 Red 40 WIRING DIAGRAMS WIRING TABLE DC2000 Signal Type Level s 10 m J20 Open 5 or 0 Vdc Manual Three Button Dry Close N 0 5 or 0 Vdc Reset Switch Stop N O Out 5 or 0 Vdc Reset Switch Common Manual One Button Dry Radio Out OV Key Switch Dry Radio Relay Reset Switch Interlock Assy Reset Switch Interlock Assembly 5 One Button e Manual One Button Dry Key Switch Out OV Key Switch Dry Radio Relay ESI Radio 12 Vdc 12 or 0 Vdc Photoelectric Sensor 12 Vdc Photoelectric Sensor 12 Vdc NOTE All devices wired to the DC2000 MUST be dedicated to LiftMaster it alone Normal operation will be controlled by
24. RELEASE 32 ACCESSORIES 33 WIRING DIAGRAMS 34 d s titrate RR E pee 34 WIRING TABLE SL3000UL81 35 SES000U DMBIM 25 icq ake ER ain ed 36 WIRING TABLE SL3000ULDM8 37 SESO00OULTHPOIM ane ch ER dupe ren 38 WIRING TABLE SL3000UL1HP8 39 DC2000 FOR SINGLE AND DM 40 WIRING TABLE 06200077 41 TROUBLESHOOTING 42 THE GATE WILL NOT OPERATE WITH 42 RESETTING MOTOR O 42 TROUBLESHOOTING 43 REPAIR PARTS 44 REPAIR PARTS ILLUSTRATIONS 44 HOW TO ORDER REPAIR PARTS 45 REPAIR PART NAMES AND NUMBERS 45 SYSTEM DIAGRAM 46 INSTALLATION CHECKLIST 47 WARRANTY POLICY 48 AWARNING Mechanical AAWARNING Electrical CAUTION When you see these Safety Symbols and Signal Words on the following pages they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them The hazard may come from something mechanical or from electric shock Read the warnings carefully When you see this Signal Word on the following pages it will alert you to the possibility of damage to your gate an
25. ROTECTION DEVICES Non Contact Sensors 12 Vdc Photoelectric Sensors NOTE Property owners are obligated to test photoelectric sensors monthly See Accessories for part number Entrapment Non Contact Sensor z tc d tc e 7 wW AWARNING To prevent SERIOUS INJURY or DEATH from a moving gate Locate entrapment protection devices to protect in BOTH the open and close gate cycles Locate entrapment protection devices to protect between moving gate and RIGID objects such as posts or walls NOTE If the photoelectric beam gets blocked while the gate is closing it will stop and reopen The gate will remain open until the obstruction is cleared Safety Non Contact Sensor I y IL uu ul l G B A Center Lus Link Loop r7 Loop KeySwitch E LL Class 2 Supply ys It is best to use Failsafe Photoelectric Sensors for this Safety Option Failsafe Photoelectric Sensors a failsafe photoelectric sensor is not working loses power or photoelectric beam is blocked then the photoelectric beam will stop ALL gate operation Contact your local dealer for more information about photoelectric sensors 24 WIRING OMNICONTROL BOARD CONNECTIONS NOTE Refer to the OmniControl board manual for more specific information 2 9 44666166 Purchased separately from LiftMaster See Accessories ALARM
26. T NUMBER PART NAME e MODEL NUMBER Address orders to LIFTMASTER Technical Support Group 6050 S Country Club Road Tucson Arizona 85706 REPAIR PART NAMES AND NUMBERS Crank Housing Kit K75 50932 Manual Crank not Included Power Back Up Unit ODC2000SL Drive Belt DC SL Q164 Drive Belt DC SL DM Q065 Back Up Motor DC 12V Chassis DC Back Up Hardware Kit for DC Back Up Wire Harness DC2000 Pulley DC2000 1 2 ID Idler Pulley Assembly Q013 Bushing 7 8 OD 120 Wall x 1 950 Pulley Idler Molded Plastic SL Screw Hex 5 8 11 x 2 3 4 Grade 5 Nut Hex Jam 5 8 S Z Washer Flat 5 8 SAE S Z Limit Switch Assembly 0024 Limit Switch Bolt Limit Switch Adjustment Nuts Limit Switch Sprocket Limit Switch Bearing Holder Collar 3 8 Control Box Assembly K75 34709 5 Electronic Metal Box Surge Suppressor Audio Alarm Dust Guard Hardware Kit 77 50382 Chain Bolt Chain Bracket NOTE Assembly Parts Number 45 1941240D Chain no 41 10 ft 1940240D Chain no 40 10 ft 1941240DNP Chain no 41 Nickel Plated 1950307 Master Link no 41 1950310 Master Link no 40 K23 51158 Reset Switch Assembly K75 50893 Safety and Interlock Assembly G6518SL Heater K73 36702 SL 3000 Chassis K82 PX06 05 PC Board Screws Q014 Drive Sprocket Q015 Gear Reducer 32 50091 10 Gear Reducer M
27. THE IMPLIED WARRANTIES WITH RESPECT TO THE SL3000UL8 WHICH ARE LIMITED IN DURATION TO THE 7 YEAR RESIDENTIAL 5 YEAR COMMERCIAL LIMITED WARRANTY PERIOD FOR THE SL3000UL8 AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD Some States do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you THIS LIMITED WARRANTY DOES NOT COVER NON DEFECT DAMAGE DAMAGE CAUSED BY IMPROPER INSTALLATION OPERATION OR CARE INCLUDING BUT NOT LIMITED TO ABUSE MISUSE FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE UNAUTHORIZED REPAIRS OR ANY ALTERATIONS TO THIS PRODUCT LABOR CHARGES FOR REINSTALLING A REPAIRED OR REPLACED UNIT OR REPLACEMENT OF BATTERIES THIS LIMITED WARRANTY DOES NOT COVER ANY PROBLEMS WITH OR RELATING TO THE GARAGE DOOR OR GARAGE DOOR HARDWARE INCLUDING BUT NOT LIMITED TO THE DOOR SPRINGS DOOR ROLLERS DOOR ALIGNMENT OR HINGES THIS LIMITED WARRANTY ALSO DOES NOT COVER ANY PROBLEMS CAUSED BY INTERFERENCE ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE TO YOU UNDER NO CIRCUMSTANCES SHALL SELLER BE LIABLE FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES ARISING IN CONNECTION WITH USE OR INABILITY TO USE THIS PRODUCT IN NO EVENT SHALL SELLER S LIABILITY FOR BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE OR STRICT LIABILITY EXCEED THE COST OF THE PRODUCT COVERED HEREBY NO PERSON IS AUTHORIZED TO ASSUME FOR US
28. Timer on Primary Board Only 3 to 60 seconds NOTE If a secondary safety sensor device is NOT used when the timer is ON the gate WILL hit a vehicle obstructing the gate path before reversing during the close cycle With Timers OFF 1 Turn BOTH timers OFF NOTE Push button once to open gate push button again to close gate 28 ADJUSTMENTS ADJUSTING REVERSING SENSOR S Adjust the Reverse Sensor on the OmniControl board Alarm Sensor does not need to be adjusted except where noted below The level of reverse sensitivity depends on the weight of the gate and the condition of installation Sensor is set too sensitive If the gate stops in mid cycle or reverses by itself Sensor is not set sensitive enough If the gate hits an object and does not stop or reverse SAN TIT 20 Maximum Sensitivity O factory set Minimum Sensitivity OmniControl 0020007 Reverse Sensor The DC2000 has a separate reverse sensor that will need to be adjusted The 120 Vac operator power needs to be turned off and the DC2000 should have the Charge OK LED ON to make the adjustment Maximum Sensitivity Minimum Sensitivity 29 MAINTENANCE AND OPERATION IMPORTANT SAFETY INSTRUCTIONS A AWARNING To reduce the risk of SEVERE INJURY or DEATH READ AND FOLLOW ALL INSTRUCTIONS 5 Use the emergency release ONLY when the gate is NEVER let childr
29. VEHICULAR SLIDE GATE OPERATOR OWNER S MANUAL Model SL3000UL8 Your model may look different than the model illustrated in this manual THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY Visit www liftmaster com to locate a professional installing dealer in your area This model is for use on vehicular passage gates ONLY and not intended for use on pedestrian passage gates This model is intended for use in Class II and IV vehicular swing gate applications e UL us LISTED UL991 1325 compliant compliant e LiftMaster 845 Larch Avenue gt Elmhurst IL 60126 1196 ELITE SERIES TABLE OF CONTENTS SPECIFICATIONS AND WARNINGS 2 SL3000UL8 MODELS OVERVIEW 2 UL325 MODEL CLASSIFICATIONS 3 SAFETY INSTALLATION INFORMATION 4 GATE CONSTRUCTION INFORMATION 5 SAFETY INSTALLATION INFORMATION 6 WARNING SIGN PLACEMENT 6 REQUIRED ENTRAPMENT PROTECTION DEVICE LOCATIONS 7 REQUIRED ENTRAPMENT PROTECTION DEVICE LOCATIONS 8 INSTALLATION 9 INSTALLATION SETUPS 9 SAFETY CATCH ROLLERS AND GATE RAIL STOPS 10 MOUNTING 11 POST MOUNTING PLATE OPTIONAL 11 CHAIN INSTALLATION TYPES
30. WIRING DC2000 DEVICE WIRING Manually Operated DC2000 Devices Manual external devices should be dry contact which do not consume any current like push buttons or a key switch Key switch is for property owner s emergency access ONLY DO NOT USE FOR AN EMERGENCY FIRE POLICE KEY ACCESS Contact your local Fire Police municipalities for more information on correct Fire Police emergency key access Manual One Button Manual 3 Button Push and HOLD button to Open Push and HOLD a button to operate Push button again and HOLD to Close Reset button and interlock wires Do Not Remove Manual Key Switch Turn and HOLD key to Open Turn key again and HOLD to Close DC2000 Entrapment Protection Devices It is recommended using separate entrapment protection devices to maintain gate safety when the DC2000 is needed for any reason The entrapment protection devices connected to the OmniControl board and surge suppressor WILL NOT protect the gate when there is a AC power failure and the DC2000 is used See Accessories for part number Edge Sensor OmniControl Board Sensor Connection Photoelectric Sensor Failsafe Photoelectric Sensor If a photoelectric sensor is not working loses power or photoelectric sensor is blocked then the photoelectric sensor will stop all gate operation 20 WIRING PLUG IN LOOP DETECTOR WIRIN
31. an absorb the tremendous power of a direct lightning strike proper grounding can protect the gate operator in most cases The earth ground rod must be located within 3 feet from the gate operator Use the proper type earth ground rod for your local area The ground wire must be a single whole piece of wire Never splice two wires for the ground wire If you should cut the ground wire too short break it or destroy its integrity replace it with a single wire length 15 CAUTION To AVOID damaging gas power or other underground utility lines contact underground utility locating companies BEFORE digging Single piece of 12 gauge wire local codes for proper depth WIRING 120 VAC POWER CONNECTION __Y _ Green Ground Connect the black Peet aroung white and ground wire from the junction box to the 120 Vac power supply Green Ground e On Off switch for operator Use a 20 amp dedicated circuit for each operator Input power 120 Vac 60 Hz SES CHASSIS s j GROUND Earth Ground Rod Highly Recommended Power supply in i See previous page Green Ground waterproof conduit 120 Vac Power Wire 16 Gauge 14 Gauge 12 Gauge 10 Gauge 8 Gauge 4 Gauge 1 2 HP and Dual Motor up to 150 FT 250 FT 400 FT 650 FT 1000 FT 2200 FT 1 HP up to 75 FT 125 FT 200 FT 325 FT 500 FT 1100 FT HEATER POWER CONNECTIO
32. and a swing gate when in the open position shall not be less than 16 inches 406 mm refer to ASTM F2200 for exception Class IV vehicular horizontal swing gates shall be designed constructed and installed in accordance with security related parameters specific to the application in question 4 1 1 4 1 1 1 4 1 1 2 4 2 SPECIFICATIONS AND WARNINGS SAFETY INSTALLATION INFORMATION THE SL3000UL8 IS FOR USE ON VEHICULAR PASSAGE GATES ONLY AND NOT INTENDED FOR USE ON PEDESTRIAN PASSAGE GATES AWARNING To prevent SERIOUS INJURY or DEATH from a moving gate Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate Locate entrapment protection devices to protect in BOTH the open and close gate cycles Locate entrapment protection devices to protect between moving gate and RIGID objects such as posts or walls Property owners MUST never mount any gate operating device near the gate s path Property owners MUST never allow anyone to hang or ride on the gate Property owners MUST never let pedestrians cross the path of a moving gate WARNING SIGN PLACEMENT Moving Gate Can Cause Serious Injury or Death KEEP CLEAR Gate may move at any time without prior warning AWARNING To prevent SERIOUS INJURY or DEATH from a moving gate Install Warning signs on BOTH sides of EACH gate in PLAIN VIEW
33. apter White 0 Vdc Relay Adapter Black 0 Vdc Plug In Exit Loop Wire 2 to 10 Vdc Plug In Loop Detector Loop Wire Inputs Plug In Safety Loop Wire 2 to 10 Vdc Not Used 16 Pins 1 HP Board Ee 210 e Not Used 1 G M S Link In Out 0 Vdc Primary Secondary Link M S Link In Out 5 or 0 Vdc MIS Link In Out 5 or 0 Vdc J11 10 Pins Not Used Plug In Loop Detector Inputs Safety Loop Detector 5 or 0 Vdc Exit Loop Detector 5 or 0 Vdc OmniControl Surge Suppressor G M S Link G In Out 0 Primary Secondary Link Input B 5 Link B In Out 5 or 0 Vdc A MIS Link A In Out 5 or 0 Vdc Fire Dept Key Switch Radio Receiver Strike Open Push Button Fire Dept Key Switch y Fire Dept Key Switch Inputs J9 J10 EUN ows roa Ron Ron Radio Receiver 11 Radio Receiver 12 Radio Receiver 13 Not Used External Loop Detector Center Safety Exit Safety External Loop Detector In 2 to 10 Vdc Wires Input Exit External Loop Detector In 2 to 10 Vdc NOTE See diagram on previous page PO n 37 WIRING DIAGRAMS SL3000UL1HP8 White Neutral Green Ground Black 120Vac Reu Black i ni White OmniControl Board D 1 HP Board 1 S Laut iGreen M nii 3 Black otor D 5 White i 52 6Green Motor Input Power S 4 Black
34. ch and Interlock Assembly Input Reset Switch Interlock Red Reset Switch Interlock Black UL Alarm Red UL Alarm and Safety Sensors UL Alarm Black Safety Sensor Safety Sensor Relay Adapter Red 5 ri ve ie Relay Adapter Module Input Relay Adapter White Relay Adapter Black 9 Vac Plug In Exit Loop Wire 2 to 10 Vdc Plug In Loop Detector Loop Wire Inputs Plug In Safety Loop Wire 2 to 10 Vdc Not Used 16 Pins 1 HP Board 0 7 Not Used G M S Link In Out 0 Vdc Primary Secondary Link B M S Link In Out 5 or 0 Vdc A M S Link In Out 5 or 0 Vdc 10 Pins Not Used Plug In Loop Detector Inputs 10 Pins Safety Loop Detector 5 or 0 Vdc 10 Pins Exit Loop Detector 5 or 0 Vdc OmniControl Surge Suppressor G M S Link G In Out Primary Secondary Link Input B M S Link B In Out 5 or Vdc A MIS Link A In Out 5 or 0 Vdc Fire Dept Key Switch 7 Radio Receiver Strike Open Push Button Fire Dept Key Switch 8 y Fire Dept Key Switch Inputs Strike Open Push Button 9 Strike Open Push Button 1 Radio Receiver 11 Radio Receiver 12 Radio Receiver 13 gc gt D O 4 CO Not Used External Loop Detector Center Safety Exit Safety External Loop Detector Wires Input Exit External Loop Detector bb sica NOOB CO PO DOAN NOTE See diagram on previous page 35 WIRING DIAGRAMS SL3000ULDM8
35. ch as at the leading edge trailing edge and post mounted both inside and outside of a vehicular horizontal slide gate b One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate c A hard wired contact sensor shall be located and its wiring arranged so the communication between the sensor and the gate operator is not subject to mechanical damage d wireless contact sensor such as the one that transmits radio frequency RF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not obstructed or impeded by building structures natural landscaping or similar obstruction wireless contact sensor shall function under the intended end use conditions e One or more contact sensors shall be located on the inside and outside leading edge of a swing gate Additionally if the bottom edge of a swing gate is greater than 6 152 mm above the ground at any point in its arc of travel one or more contact sensors shall be located on the bottom edge f One or more contact sensors shall be located at the bottom edge of a vertical barrier arm 4 SPECIFICATIONS AND WARNINGS GATE CONSTRUCTION INFORMATION Vehicular gates should be installed in accordance with ASTM F2200 Standard Specification for Automated Vehicular Gate Construction For a copy contact ASTM directly at 610 832 9585 or www astm org 1 General Requirements 1 1 1 2
36. cuts 04 Le Home Run sj t 1 8 to 1 4 Width Saw Cut Feeder Slot Contact your local dealer Road Surface for more information about loop detectors Recommended Loop Wire XLPE 12 18 gauge Use heavier wire gauge for a more durable loop Sealant Backer Rod NOTE Wire mesh or reinforcement 2 to 2 5 Depth embedded in the road surface should Saw Cut be cut away a minimum of 6 inches from the perimeter of the loop Insulated loop wire 3 turns shown amount varies Refer to table 22 WIRING ENTRAPMENT PROTECTION DEVICES Contact Sensors Edge Sensor AWARNING To prevent SERIOUS INJURY or DEATH from a moving gate Locate entrapment protection devices to protect in BOTH the open and close gate cycles Locate entrapment protection devices to protect between moving gate and RIGID objects such as posts or walls NOTE When touched these electrically activated edge sensors immediately signal the gate operator to stop and reverse Property owners are obligated to test edges monthly See Accessories Entrapment Danger a Parallel Connection Open Sensor on Wall 215615 ALARM Open Sensor on Wall L x il Close Sensor on Wall Connect all edge sensors to the sensor connection Close Sensor on Gate WIRING ENTRAPMENT P
37. d 13 Short circuit at any of the loop detectors in the board Short circuit in the control board Excessive current draw at terminal 13 Over voltage at the 120 Vac line input Motor thermal fuse has popped out Rapid Flashing One limit switch is faulty Rapid Flashing Gate has encountered an obstruction during traveling Reverse sensor is extra sensitive Gate encountered an obstruction during traveling Alarm sensor is extra sensitive There is a command hold active There is a command holding the gate open Gate has reopened because it encountered an obstruction while closing Gate has encountered two consecutive obstructions while trying to close or open The loop detector needs to be reset The wire loop has been disrupted The loop detector needs to work in a different frequency The loop detector is too sensitive For technical support 1 800 528 2806 43 1 Remove the short circuit condition at the terminals Remove the defective loop detector Send the board to repair Reduce the accessories load from surge suppressor terminal 13 Verify your electrical power Reset the motor Test the limit switches and wire connections fix the fault Remove the obstruction Turn the reverse sensor switch counter clockwise a little more and try again Remove the obstruction Turn the alarm sensor switch counter clockwise a litt
38. d or the gate operator if you do not comply with the cautionary statements that accompany it Read them carefully IMPORTANT NOTE BEFORE attempting to install operate or maintain the operator you must read and fully understand this manual and follow all safety instructions DO NOT attempt repair or service of your gate operator unless you are an Authorized Service Technician SPECIFICATIONS AND WARNINGS SL3000UL8 MODELS OVERVIEW Single Motor Models SL3000UL8 Single Motor 1 2 HP Motor 120 Vac 4 Amp Maximum Gate Length 37 ft Maximum Gate Weight 1000 Ibs Maximum Pull 105 Ibs SL3000ULDC8 Single Motor 1 2 HP Motor DC2000 120 Vac 4 Amp Maximum Gate Length 37 ft Maximum Gate Weight 1000 Ibs Maximum Pull 105 Ibs SL3000ULH8 Single Motor 1 2 HP Motor 120 Vac 4 Amp Heater 3 Amp Maximum Gate Length 37 ft Maximum Gate Weight 1000 Ibs Maximum Pull 105 Ibs SL3000ULDCH8 Single Motor 1 2 HP Motor DC2000 120 Vac 4 Amp Heater 3 Amp Maximum Gate Length 37 ft Maximum Gate Weight 1000 Ibs Maximum Pull 105 Ibs Dual Motor and 1 HP Motels SL3000ULDM8 Dual Motor Two 1 2 HP Motors 120 Vac 4 7 Amp Maximum Gate Length 37 ft Maximum Gate Weight 800 Ibs Maximum Pull 100 Ibs SL3000ULDMDC8 Dual Motor Two 1 2 HP Motors DC2000 120 Vac 4 7 Amp Maximum Gate Length 37 ft Maximum
39. der Gate systems design and installation must reduce public exposure to potential hazards gate operator can create high levels of force in its function as a component part of a gate system Therefore safety features must be incorporated into every design Specific safety features include Gate Edges e Guards for Exposed Rollers e Photoelectric Sensors e Screen Mesh Vertical Posts Instructional and Precautionary Signage Install the gate operator only when a The operator is appropriate for the construction and the usage class of the gate b All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 1 2 m above the ground to prevent a 2 1 4 6 cm diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjacent fence that the gate covers in the open position c All exposed pinch points are eliminated or guarded and guarding is supplied for exposed rollers The operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate The gate must be installed in a location so that enough clearance is supplied between the gate and adjacent structures when
40. eck for proper synthetic oil level in the gear box 10W 30 weight synthetic oil Severe or high cycle usage will require more frequent maintenance checks Inspection and service should always be performed anytime a malfunction is observed or suspected When servicing please do some house cleaning of the operator and the area around the operator Pick up any debris in the area Clean the operator as needed It is suggested that while at the site voltage readings be taken at the operator Using a Digital Voltmeter verify that the incoming voltage to the operator it is within ten percent of the operators rating Verify all safety and entrapment devices are functioning 30 MAINTENANCE AND OPERATION BUILT IN RESET SWITCH When the gate operator s audio alarm has been tripped see below the reset switch must be pushed for the operator to function again The reset switch will shut off an activated audio alarm and reset the operator to function again If the audio alarm goes off always check the gate area for e Obstructions in the gate path e Damage to the gate and or gate operator Pressing the reset switch will stop a moving gate during a normal open close cycle like a stop button The operator does NOT need to be reset after doing this AUDIO ALARM The alarm could be tripped when one of the following happens twice consecutively then the alarm will sound for 5 minutes or until the reset switch is pressed Pre
41. edestrian access and to vehicular gates not to be automated Any existing automated gate when the operator requires replacement shall be upgraded to conform to the provisions of this specification in effect at that time 3 Vehicular Horizontal Slide Gates 3 1 3 1 1 3 1 2 The following provisions shall apply to Class Class and Class vehicular horizontal slide gates All weight bearing exposed rollers 8 feet 2 44 m or less above grade shall be guarded or covered All openings located between 48 inches 1 22 m and 72 inches 1 83 m above grade shall be designed guarded or screened to prevent a 4 inch 102 mm diameter sphere from passing through the openings anywhere in the gate and in that portion of the adjacent fence that covers in the open position 3 1 3 A gap measured in the horizontal plane parallel to the roadway between a fixed stationary object nearest the roadway such as a gate support post and the gate frame when the gate is in either the fully open position or the fully closed position shall not exceed 2 1 4 inches 57 mm refer to ASTM F2200 for Exception Positive stops shall be required to limit travel to the designed fully open and fully closed positions These stops shall be installed at either the top of the gate or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function All gates shall be d
42. elay Adapter Module Input 0 Vdc 0 Vdc 10 Vdc Plug In Loop Detector Loop Wire Inputs 10 Vdc 120 Vac 1 HP Board Input In Out 0 Vdc Primary Secondary Link In Out 5 or 0 Vdc Plug In Loop Detector Inputs 2t 2t 2t In Out 5 or 0 Vdc 5 or 0 Vdc 1 HP Board 2 Motors Input OmniControl Surge Suppressor G M S Link 6 B M S Link B A M S Link A Fire Dept Key Switch 7 Fire Dept Key Switch 8 Strike Open Push Button 9 Strike Open Push Button 10 Radio Receiver 11 Radio Receiver 12 Radio Receiver 13 Not Used Safety External Loop Detector Exit External Loop Detector ows omn ms In Out 0 Primary Secondary Link Input In Out 5 or 0 Vdc In Out 5 or 0 Vdc Dry Radio Receiver Strike Open Push Button Fire Dry Dept Key Switch Inputs 5 or 0 Vdc V 2 to 10 Vdc 2 to 10 Vdc 39 NOTE See diagram on previous page External Loop Detector Center Safety Exit Wires Input WIRING DIAGRAMS DC2000 FOR SINGLE AND DM 4 m m NOTE This diagram only shows the DC2000 wiring and all other wiring not shown is the same as the diagram on the single or dual motor models The 1 HP models Can Not have the DC2000 Battery Backup system Hi SENSOR ALARM 2 1021 E SE SYSTEM
43. en operate or play with gate controls NOT moving Keep the remote control away from children 6 KEEP GATES PROPERLY MAINTAINED Read the ALWAYS keep people and objects away from the gate owner s manual Have a qualified service person make NO ONE SHOULD CROSS THE PATH OF THE MOVING repairs to gate hardware GATE The entrance is for vehicles ONLY Pedestrians MUST Test the gate operator monthly The gate MUST reverse use separate entrance on contact with a rigid object or stop when an object Disconnect ALL power BEFORE performing ANY activates the non contact sensors After adjusting the maintenance force or the limit of travel retest the gate operator 9 ALL maintenance MUST be performed by a LiftMaster Failure to adjust and retest the gate operator properly professional can increase the risk of INJURY or DEATH 10 SAVE THESE INSTRUCTIONS MAINTENANCE lt A OQ d WH Disconnect power before servicing The gate area should be kept clean to insure proper operation Check for belt tightness Check chain for tightness Refer to chain distance and height page Make sure the reversing sensor is functioning properly Check it monthly page 29 Make sure the gate track is clear of dirt rocks or other substances Make sure the wheels are operating smoothly on the track Oil the chain regularly with a chain lubrication oil available at most motorcycle stores Ch
44. er pulley MUST have safety cover Earth Ground is highly recommended Weld physical stops Use the proper type earth ground rod for your area on ends of gate rail Primary Secondary Operators y UL approved catch rollers with safety covers Maximum gate length 37 ft for each gate Maximum gate weight varies for operators Separate power supply for each operator Warning Placard on both sides of each gate 2 inch wire grid safety screen 48 inches high Low Voltage UL approved conduit High Voltage UL approved conduit Earth Ground is highly recommended for each operator Weld physical stops Use the proper type earth ground rod for your area on ends of gate rail Concrete Pad INSTALLATION SAFETY CATCH ROLLERS AND GATE RAIL STOPS Safety Catch Rollers DO NOT use a Gate Catch Post Because the coasting distance may vary due to changes in temperature it is NOT recommended to install a stop or catch post in front of the gates path To do so will cause the gate to hit the post in certain instances Gate Rail Stop It is only recommended installing catch rollers with safety covers on the side of a post or wall with a minimal distance of half an inch between the rollers and gate When fully opened the end of the sliding gate should stop at least five inches from an obstructing wall 1 End View of Gate and Wall NOTE For safety
45. esigned with sufficient lateral stability to assure that the gate will enter a receiver guide refer to ASTM F2200 for panel types The following provisions shall apply to Class IV vehicular horizontal slide gates All weight bearing exposed rollers 8 feet 2 44 m or less above grade shall be guarded or covered Positive stops shall be required to limit travel to the designed fully open and fully closed positions These stops shall be installed at either the top of the gate or at the bottom of the gate where such stops shall horizontally or vertically project no more than is required to perform their intended function 3 2 3 2 1 3 2 2 4 Vehicular Horizontal Swing Gates 4 1 The following provisions shall apply to Class I Class Il and Class III vehicular horizontal swing gates Gates shall be designed constructed and installed so as not to create an entrapment area between the gate and the supporting structure or other fixed object when the gate moves toward the fully open position subject to the provisions in the 4 1 1 1 and 4 1 1 2 The width of an object such as a wall pillar or column covered by a swing gate when in the open position shall not exceed 4 inches 102 mm measured from the center line of the pivot point of the gate refer to ASTM F2200 for exception Except for the zone specified in Section 4 1 1 1 the distance between a fixed object such as a wall pillar or column
46. ide removable terminal connections DO NOT let wire insulation interfere with connection Remote NOT Included Second Operator Link Separate Power 315 MHz Factory Installed Radio Receiver 955509555 i Separate power for card reader External 120 Vac Safety Loop Detector Separate Power Push Button Dry Contact Telephone Entry System Separate power for TES 12 Vdc Failsafe Photoelectric Sensor NOTE Terminals 11 and 12 are the ONLY terminals that will Open and Close with a single push of a button All other terminals will ONLY Open with a single push of a button Fire or any Key Switch Dry Contact 14 WIRING To reduce the risk of SEVERE INJURY or DEATH ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking out the power Upon completion of maintenance the area MUST be cleared and secured at that time the unit may be returned to service Disconnect power at the fuse box BEFORE proceeding Operator MUST be properly grounded and connected in accordance with local electrical codes NOTE The operator should be on a separate fused line of adequate capacity ALL electrical connections MUST be made by a qualified individual A AWARNING DO
47. le more and try again This is a normal response of the gate operator It does not represent necessarily that there is a problem This is a normal response of the gate operator It does not represent necessarily that there is a problem Check inputs for command Any re new command will resume normal operation Check for obstructions Any re new command will resume normal operation but not a radio command Check for obstructions You can stop the alarm by using the built in reset button You can stop the alarm by using an optional stop button Reset the loop detector If you use LiftMaster Plug in Loop detectors change the setting for sensitivity and come back to your original setting Verify and correct connections Set a different working frequency Decrease the sensitivity of the loop detector REPAIR PARTS REPAIR PARTS ILLUSTRATIONS ODC2000SL K75 51048 75 50932 LP K75 50893 K10 36700 Master Link 0 in lt mE 6651851 lt E Ce 36702 13 34729 77 50382 NOTE Sold Individually 2 shown 44 list on next page REPAIR PARTS HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZATION SPANS AMERICA INSTALLATION AND SERVICE INFORMATION IS AS NEAR AS YOUR TELEPHONE SIMPLY DIAL OUR TOLL FREE NUMBER 1 800 528 2806 www liftmaster com WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PAR
48. n differs when DC2000 is used Surge Suppressor J10 3to J13 A J10 2 to J12 B J10 1 to J1 1 G Primary Secondary Connection to OmniControl Board NOTE See table on next page Omni Option Board Optional 36 Green Chassis Ground wo OJ White Black Red Green Black Radio Harness WIRING DIAGRAMS WIRING TABLE SL3000ULDM8 amp OmniControl Board Signal Type Level 10 Input Connection J1 In Safety Loop 5 or 0 Vdc External Loop Detector Wires 120 Vac Input Power Neutral OV Power Radio Receiver Strike Open Key Not Used Switch Harness Input Power 120 Vac 120 Vac Strike Open 5 or 0 Vde Exit Loop 5 or 0 Vde Radio Receiver V Radio Receiver 0 Fire Dept Key Switch Radio Receiver 10 Pins OmniControl Board 24 OmniControl Board Input 0V Limit Switch Red Motor s Limit Switches Motor White Maglock Solenoid Harness Normally Closed No Wire Motor Black Limit Switch Brown Com Motor Red Purple Com Blue N O Limit Switch Yellow Com Limit Switch Orange N O O O1 gt Co PO O Reset Switch and Interlock Assembly Input Reset Switch Interlock Red Reset Switch Interlock Black UL Alarm Red UL Alarm and Safety Sensors UL Alarm Black Safety Sensor Safety Sensor OV Relay Adapter Red 5 or 0 Vdc Relay Adapter Module Input Relay Ad
49. neral access vehicular gate operator A vehicular gate operator or system intended for use in a commercial location or building such as a gt lt multi family housing unit five or more single family units hotel garage retail store or other building servicing the general public Class Industrial limited access vehicular gate operator A vehicular gate operator or system intended for use in a industrial location or building such as a E 5 factory or loading dock area or other location not intended to service the general public TNT Class IV Restricted access vehicular gate operator A vehicular gate operator or system intended for use in a guarded industrial location or building such as an airport security area or other restricted access locations not servicing the general public in SIT which unauthorized access is prevented via supervision by security personnel m UL325 ENTRAPMENT PROTECTION REQUIREMENTS This chart illustrates the entrapment protection requirements for each of the four UL325 classes In order to complete a proper installation you must satisfy the entrapment protection chart shown That means that the GATE OPERATOR ENTRAPMENT PROTECTION installation must have one primary means of entrapment UL325 Slide Gate Operator protection and one independent secondary means of Installation Classification entrapment p
50. odel SL3000ULE8 only Q016 Limit Switch Drive Sprocket Q018 1 2 HP Electric Motor Q020 Drive Belt Q021 Gear Pulley Q025 Motor Pulley Q027 Motor Capacitor 0028 Manual Crank 0029 Limit Switch Q030 Limit Switch Chain 0039 Drive Belt DM and 1 HP Q237 Crank Input K75 51048 Cover HD Polyethylene SL 04000 Omni Main PCB OmniControl 0401 Omni 1 HP Board 0404 Omni Siren 0407 Omni Motor Harness 1 HP K10 36700 Junction Box with On Off Switch and Receptacle K13 34729 Dust Guard 0410 Surge Suppressor Terminal Block 0420 Omni Motor Harness Single Motor 0421 Omni Motor Harness DM 850LM Radio Receiver SYSTEM DIAGRAM 46 INSTALLATION CHECKLIST 1 Owner and Installer must read all warnings and safety precautions 2 Make sure concrete mounting pad is big enough and deep enough for operator 3 Operator must be securely fastened to concrete pad 4 Operator chain must be 4 inch minimum from gate Chain must not be too tight or too loose 5 Gate operator sho
51. onnect CH3 to the STOP input of the OmniControl Board 1 Press and release the CH1 Learn button on the receiver 2 Within 30 seconds press the desired OPEN button on the remote control 3 Press and release the CH2 Learn button on the receiver 4 Within 30 seconds press the desired CLOSE button on the remote control 5 Press and release the CH3 Learn button on the receiver 6 Within 30 seconds press the desired STOP button on the remote control NOTE If a remote control button is not pressed within 30 seconds the LED next to the selected Learn button will turn OFF In that case repeat the programming To Erase the Memory 1 Press and hold the Learn button for the channel you want to erase Release the button when the corresponding LED turns off the memory has been erased Optional Remote Controls See Accessories 21 AWARNING To prevent possible SERIOUS INJURY or DEATH from electrocution Be sure power is NOT connected BEFORE installing the receiver To prevent possible SERIOUS INJURY or DEATH from a moving gate or garage door ALWAYS keep remote controls out of reach of children NEVER permit children to operate or play with remote control transmitters Activate gate or door ONLY when it can be seen clearly is properly adjusted and there are no obstructions to door travel ALWAYS keep gate or garage door in sight until completely closed NEVER permit anyone to cross path of moving ga
52. re turn loop See Installing Insulated Loop Wire on next page for more information Contact your local dealer for information about plug in loop detectors 21 WIRING 120 VAC EXTERNAL LOOP DETECTOR WIRING G BA 120 Vac Safety Loop Detector Allows gate to stay open when vehicles are obstructing path CAUTION Suggested for vehicles 14 feet or longer If a vehicle is shorter a center loop system is recommended and should be installed If the Inside and Outside safety loops are connected to the same loop detector They should be series connected to the detector Have the same dimensions Have the same number of wire turns See table below Safety Loop 120 Vac Exit Loop Detector Allows gate to automatically open for exiting vehicles Exit Loop Installing Insulated Loop Wire Number of Wire Turns Needed for Loop Sizes Loop Perimeter Number of Wire Turns 10 feet to 13 feet E 14 feet to 26 feet 27 feet to 80 feet The wire is continuously wound in 3 the loop saw cut for the required 4 number of turns One turn shown 9 80 feet and up Refer to table 4 The wire MUST be twisted together minimum 6 Saw Cut twists per foot from the end of the feeder slot to the Q Remove sharp inside ALLIE p loop detector by making corner
53. reasons physical stops MUST be installed on both ends of the gate rail prior to installation of the gate operator This Will assure that the gate does not derail while opening or closing fully 10 INSTALLATION MOUNTING OPERATOR Suggested installation for dirt ground The measurements depend on the type of ground ie asphalt cement dirt Check local building codes before installation Top Inside View Conduit area without battery back up 4 Concrete Anchors 1 2 x 3 1 2 High voltage conduit Above Ground 6 Low voltage conduit Below the frost line Check all local codes Concrete Reinforced Recommended 3 heavy steel posts can be U bolted to mounting plate and Post Mounting Plate cemented in ground Power and control wiring should be run 4 in separate conduits 11 INSTALLATION CHAIN INSTALLATION TYPES Drawings not to scale Front Operator Position Weld rear bracket with gate in closed position AWARNING To reduce the risk of SERIOUS INJURY or DEATH make sure exposed idler pulleys have safety covers on them Weld front bracket with gate in open position CHAIN DISTANCE AND HEIGHT ON GATE Correct Installation Don t connect chain too tight to gate Gate is 4 inches minimum distance away from drive sprocket and parallel to gate
54. rotection Both primary and secondary entrapment protection methods must be designed arranged Class I Class IV B1 or B2 or configured to protect against entrapments in both the open and close directions of gate travel For Example For a gate system that is installed on a single family residence UL325 Class 1 you must provide the following Type A Inherent built into the operator entrapment sensing and at least one of the following as your secondary entrapment protection Type B1 Non contact sensors such as photo eyes or Type B2 Contact sensors such as gate edges 17 Il m VIS NOTE UL requires that all installations must have warning signs placed in plain view on both sides of the gate to warn pedestrians of the dangers of motorized gate systems 3 SPECIFICATIONS AND WARNINGS SAFETY INSTALLATION INFORMATION 1 2 10 11 12 Vehicular gate systems provide convenience and security Gate systems are comprised of many component parts The gate operator is only one component Each gate system is specifically designed for an individual application Gate operating system designers installers and users must take into account the possible hazards associated with each individual application Improperly designed installed or maintained systems can create risks for the user as well as the bystan
55. ss the built in reset switch to shut off alarm and reset operator see above An externally wired entrapment protection device has been triggered twice Photoelectric sensor blocked The gate wheel is off the gate rail The gate has one or more broken axles or wheels 31 MAINTENANCE AND OPERATION MANUAL DISCONNECT NOTE Use the dedicated breaker switch to disconnect power to the operator Turn the power OFF Push the crank tool in hole Safety releases will separate Turn the crank to open the gate NOTE YOU may use a cordless power drill 6 sec for quicker opening in non emergency situations Allen wrench drill bit size is 5 16 Remove crank tool OPTIONAL MANUAL RELEASE Contact your local dealer for information about a Fire Box Release Pull firmly on the T Handle to release the chain The chain is held in place by a spring loaded pin 32 ACCESSORIES Magnetic Lock Outdoor 120 Vac External Brackets Part MG1300 DC2000 Kit Loop Detector 109411 Loop dde inm Part ODC2000SL A79 Part AELD 6 1 gt V Groove Power Wheels Series E 4inch 5inch _ 6inch e eye Omni Relay Adapter Remote Controls Part Q400MAU Part 893MAX Part 811LM Part 890
56. t Power Neutral Not Used Input Power 120 Vac Strike Open Exit Loop Radio Receiver Radio Receiver Fire Dept Key Switch Radio Receiver e 5 eu 29 5 o Limit Switch Red Normally Closed No Wire Limit Switch Brown Com Purple Com Blue 0 Limit Switch Yellow Com Limit Switch Orange N O Reset Switch Interlock Red Reset Switch Interlock Black UL Alarm Red UL Alarm Black Safety Sensor Safety Sensor Relay Adapter Red Relay Adapter White Relay Adapter Black J EIN RTE Ci Plug In Exit Loop Wire Plug In Safety Loop Wire Plug In Center Loop Wire i 1 HP Board G M S Link B M S Link A M S Link Not Used Safety Loop Detector Exit Loop Detector Motor Red Motor Black Motor White Neutral Motor Black Motor White Neutral a zd D EN awn 22 10 Pins 10 Pins 10 Pins O gt sorov e J Pin Signal Type Level 10 Input Connection 5 or 0 Vdc External Loop Detector Wires 120 Vac Power 0 Radio Receiver Strike Open Key Switch Harness 120 Vac 5 or 0 Vdc OmniControl Board 24 Vdc OmniControl Board Input 5 or 0 Vdc 5 or Vdc ov ov 5 or 0 Vdc OV 5 or 0 Vdc Limit Switches Maglock Solenoid Harness Reset Switch and Interlock Assembly Input UL Alarm and Safety Sensors V 5 or 0 Vdc R
57. te or door NOTICE This device complies with Part 15 of the FCC rules and Industry Canada IC license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This Class B digital apparatus complies with Canadian ICES 003 CH2 Learn Button CH1 Learn Button CH3 Learn Button NOTE Disconnect the secondary receiver when using a primary secondary setup ADJUSTMENTS SETTING TIMER 0N OFF Single Operator To use the automatic close for the gate system the timer switch should be put in the ON position To use the push close command the timer should be switched to the OFF position Push button once to open gate pus button again to close gate Primary Secondary Operators Operators need to be connected by M S LINK See Linking Primary Secondary page 17 M S LINK Primary Secondary control boards are interchangeable Primary Board With Timers ON Secondary Board 1 Turn Primary Timer ON 2 Turn Secondary Timer OFF 3 Use
58. terlock assembly connection differs when DC2000 is used to J1 9 to J2 1 2 Fire Dept Key Switch OmniControl n 10 to J2 1 Radio Receiver LiftMaster OmniControl Surge Suppressor E NN ET Surge Suppressor 7 m FTT E Supply Primary Secondary Connection Brean Pte a A K 8 Z7 Omi geez Option Board cr iRadio Harness Optional 34 Chassis Ground Green Black NOTE See table on next page WIRING DIAGRAMS WIRING TABLE SL3000UL8 Board Signal Type Level 10 Input Connection Safety Loop 5 or 0 Vdc External Loop Detector Wires 120 Vac Input Power Neutral OV Power Radio Receiver Strike Open Key Not Used Switch Harness Input Power 120 Vac 120 Vac Strike Open 5 or 0 Vdc Exit Loop 5 or 0 Vdc Radio Receiver OV Radio Receiver OV Fire Dept Key Switch In Dry Radio Receiver O 4 e N OmniControl Board Input Limit Switch Red Motor s Limit Switches Motor White Maglock Solenoid Harness Normally Closed No Wire 5 or 0 Vdc Motor Black 120 Vac Limit Switch Brown Com OV Motor Red 5 or 0 Vdc Purple Com OV Blue N 0 5 or 0 Vdc Limit Switch Yellow Com OV Limit Switch Orange N O 5 or 0 Vdc Reset Swit
59. uld be grounded to an earth ground within 3 feet 6 Verify that power is connected properly Know where the main power disconnect is for operator s 7 Verify that the gate opens and closes as needed 8 When gate hits object during operation it must stop or reverse depending on the direction gate is traveling 9 Make sure that any pinch point or potential entrapment are guarded by means of entrapment protection devices or like 10 Warning placards need to be permanently mounted on both sides of gate s 11 Test all additional equipment connected to operator 12 Make sure all wire connections are securely fastened 13 Review typical maintenance on operator 14 Schedule periodic maintenance on operator by qualified service technician 15 Inquire about manufacturer s operator warranty Warranty card included with operator 16 Inquire about separate installation warranty with installer Installer Company Name Address and Phone Number Date of installation 47 WARRANTY POLICY 7 YEAR RESIDENTIAL 5 YEAR COMMERCIAL SL3000UL8 LIMITED WARRANTY LiftMaster Seller warrants to the first purchaser of this product for the structure in which this product is originally installed that it is free from defect in materials and or workmanship for a period of 7 year residential 5 year commercial from the date of purchase and

Download Pdf Manuals