1. a Pressure conversion chart from to pa kPa MPa kgf cm mmHg mmH O psi bar inHg 1Pa 1 0 001 0 000001000 0 000010197 0 007501 0 101972 0 000145038 0 000010000 0 0002953 1kPa 1000 000 1 0 001000 0 010197 7 500616 101 9716 0 145038 0 010000 0 2953 1MPa 1000000 1000 1 10 197162 7500 61683 101971 553 145 038243 10 295 299875 1kgf cm 98066 54 98 066543 0 09806 fl 735 5595 10000 20 14 22334 0 980665 28 95878 immHg 133 322368 0 133322 0 000133 0 001359 1 13 5954 0 019336 0 001333 0 039370 1mmH O 9 80665 0 00980 0 000099 0 0735578 1 0 00142 0 000098 0 002895 ipsi 6894 757 6 89757 0 00689 0 070307 51 71630 703 07 1 0 068947 2 036003 1bar 100000 0 100 0000 0 100000 1 019689 750 062 10196 89 14 50339 1 29 52998 1inHg 3386 417 3 388418 0 003386 0 034532 25 40022 345 31849 0 491158 0 033863 1 gt lt Ex For calculating 760mmHg as kPa According to above chart 1mmHg is 0 133322kPa therefore 760mmHg is 760 0 133322kPa 101 32472kPa a Specifications Model PSM4 V PSM4 A PSM8 V PSM8 A Display range Depending on pressure type pressure unit Refer to lm Rated pressure range Power supply 12 24VDC ripple P P max 10 Allowable voltage range 90 to 110 of rated voltage Power consumption Max 3W Current consumption Max 40mA Display di
2. Channel setting Switching Parameter 1 group is available to set for each channel Press the key key once channel is changed for the parameter suPPly Ex To set auto pressure sensor model identification Ht 5 and input display d 5P at CH1 2 3 in parameter 1 group Q Stepper CH1 auto pressure sensor CH2 auto pressure sensor CH3 auto pressure sensor a roller model identification model identification model identification acca E SE _ 7 ae _ u _ 7 R Drp E ng Z key ooce key ooce Sri C00 208 changes Da E a A changes Bad Oat a panel oe channel od channel S gt Field network device y Software Dey M key 0 key w Other VE E nE Owes Linus C00 204 me mO A b amp key amp key changes changes channel channel Autonics E 35 PSM Series a Output operation mode 1 Hysteresis mode H 5 A It is able to set certain value for pressure detection level 5t i 5t and hysteresis H95 1 H952 Parameter Set range Se Min display pressure lt 5 lt Max display pressure H951 Min display pressure lt H95 5t St2 Min display pressure lt 5 2 lt Max display pressure H952 Min display pressure lt H952 lt SEt2 Pressure Ste HYS2 St HYS OUT1 N O ON St I HY5 OFF OUT1 N C ON Se I HY5 OFF OUT2 N O ON St2 HYS2 OFF OUT2 N C ON St2 H4Se OFF Time 3 Hyster
3. n is 5HF in parameter 2 group T SSR a Auto pressure sensor model identification A 57 aret ior When connecting Autonics pressure sensor PSS Series this unit recognizes pressure model n t in parameter 1 group and pressure range automatically Counter Auto identification method Set auto pressure sensor model identification At 5 as an Turn PSM power OFF Connect PSS PSM power ON K XThis function is only for Autonics pressure sensor PSS Series Timer XTurn OFF the PSM power and connect PSS Otherwise it may cause malfunction A 0 a Channel change and setting on For manual channel change set channel auto change cycle Ht CH as 5 FF in parameter 2 group m For auto channel change set channel auto change cycle At CH as 2 or 5 in parameter 2 group PeR la Channel change meter e Manual channel change Press the K key in RUN mode The display part 2 changes channel and the display part 1 displays the value of this channel alee e Auto channel change It displays only connected channels It displays one of the connected channels and the next channel for the set time 2 or 5 sec automatically 0 Sensor In auto channel change when pressing the key to change channel it displays the value of this channel for 30 sec and it controtier displays the next channel automatically P
4. Detection hysteresis is fixed to min display range Lau Min display pressure lt Lo lt Max display pressure The pressure detection level 5E is shown in the feel display interval following calculation St 145E2 HI GH Low value 3 x Min display interval lt Hi GH lt Max i b SS display pressure H Parameter Set range Pressure 4 Min display range i Sk Min display pressure lt 5 lt Max display pressure HGH etre ai a Sa 1 of rated pressure Lot Pepe cceencn rent be re eei Ngee i Ste St 1 1 of rated pressure lt St 2 lt Max display pressure Se i SEt Automatic setting 5 5E 2 2 HYS pressure VAN X1 Min display range f See Fix OUT1 N O ON l Se t HY S OFF i 5t 1 St2 2 SEb OUTI N C ON l Stl St H95 OFF OUT2 N O ON LoY H i GH OFF OUT2 N C ON Lo Y Hi GH OFF Time Autonics E 36 OUT1 N O ON SEE OFF OUT1 N C ON SEt OFF OUT2 N O ON St 1 5 2 OFF OUT2 N C ON Se 1 5t2 OFF Time Multi CH Pressure and Sensor Indicator 5 Freezer pressure control mode F E a This mode is proper for freezer system s pressure Control Parameter Set range clectc output 1 is utilized as main output control Se I Min display pressure lt St lt Max display pressure gt Set t
5. K 5 2 HY52 OFF 5b 2 H4S2 OFF Timer OUT2N C ON OUT2N C ON St2 HYS2 OFF i SE2 HYS2 OFF L X1 X1 X1 Time Time Panel meter 6 Forced output control mode F ct t eaaa This mode is to display pressure with forcibly holding output 1 2 OFF or ON regardless of SV ppe on Pulas In RUN mode press the M key for less than 2 sec and it is forced output control mode i Whenever pressing the Y key output 1 is changed as ON or OFF in turn CURA Whenever pressing the A key output 2 is changed as ON or OFF in turn unit Aiea When pressing the KX key output of current channel maintains that status and it moves to next channel rT GAN controller Displays Forced output o current pressure 0 key operation mode q key P aco Fda Poner i supply a rper Displays current pressure unit Displays current pressure unit motor amp f y yy f Driver amp Controller ON la OUT1 R off a gt Tine Sapne i panel ouT2 oN 3 fq ee i Time Se H Al A Al i network device y Preset value setting nee Set preset value of output mode for each channel Press the M key for less than 2 sec it enters preset parameters varied i E by each output mode Sher Press the A keys to set preset value within available set range in display part 2 L a When control output mode 5UE A is F otk it does not set preset and enters forced output control mode Factory defaults of preset values are different by each output mod
6. Rated pressure Displayed pressure Min display interval Rated pressure Displayed pressure Min display interval MPa APA 0 to 1 000 0 050 to 1 100 0 001 kPa EPA 0 to 1 000 50 to 1100 1 0 to 100 0 5 0 to 110 0 0 1 kg cm EGF 0 to 10 20 0 51 to 11 22 0 01 0 to 1 020 0 051 to 1 122 0 001 Bar bAr 0 to 10 00 0 50 to 11 00 0 01 0 to 1 000 0 050 to 1 100 0 001 psi P5 0 to 145 0 7 2 to 159 6 0 1 0 to 14 50 0 72 to 15 96 0 01 Unit Negative pressure u ACU Compound pressure CoAP Rated pressure Displayed pressure Min display interval Rated pressure Displayed pressure Min display interval MPa APA an kPa EPA 0 to 101 3 5 0 to 101 3 0 1 101 3 to 100 0 101 3 to 110 0 0 1 kg cm EGF 0 to 1 034 0 051 to 1 034 0 001 1 034 to 1 020 1 034 to 1 122 0 001 Bar bAr 0 to 1 013 0 050 to 1 013 0 001 1 013 to 1 000 1 013 to 1 100 0 001 psi P51 0 to 14 70 0 74 to 14 70 0 01 14 70 to 14 50 14 70 to 15 96 0 02 mmHg AnH 0 to 760 38 to 760 1 760 to 750 760 to 824 1 inHg nHG 0 to 29 9 1 5 to 29 9 0 1 29 9 to 29 5 29 9 to 32 6 0 1 mmH20 H20 0 to 103 4 5 1 to 103 4 0 1 103 4 to 102 0 103 4 to 112 2 0 1 X1 It displays the value by dividing 100 To read this multiply the display value by 100 X Display pressure range is 5 to 110 of the rated pressure Sra E 28 Autonics Multi CH Pressure and Sensor Indicator
7. Red G G Green Green Communication address AdrS B OO Set range 01 to 127 M Communication speed E 8 Set range 24 48 96 192 384 b p 4 Multiply the display value by 100 unit bps M A Communication parity bit J B Al A Preg EuEn M M Communication stop bit 8 5EF gt gt M Communication response wait time 8B e Set range 5 to 99 unit ms Communication write B A Enn ld 5A Parameter initialization n J B E A Initializes parameters v XBe sure that all SVs are initialized M A Parameter Function Lock Peri S rece ie gt gt lt _ _ _ gt ran Lol joc LOL Yy LaL iM SEL Locks parameter setting Preset value change Lole zero point adjustment and peak values auto Yy shift correction value initialization are available e E34 Autonics Multi CH Pressure and Sensor Indicator High Low peak value Auto shift value check A PSM electric sensor AJ 2 sec key gt __ optic p for eones over 1 sec ien h Door Area nitializes nig sensor peak value Vv D Y A for Seige M key over 1 sec Initializes low 3 Pressure peak value Tiesa F Rotary encoder M key G Connector Socket YY A for over 1 sec Initialize Auto shift value and returns to RUN mode H Temp controller X1 It displays only when digital input terminal function d
8. Set pressure range after correction Set pressure range preset set range D otary Positive standard 5 2kPa to 110 0kPa 110 0kPa to 110 0kPa encode Positive lower 50 0kPa to 1 100kPa 1 100kPa to 1 100kPa Vacuum 101 3kPa to 5 0kPa 101 3kPa to 101 3kPa Socket Compound 101 3kPa to 110 0kPa 100 0kPa to 110 0kPa fer M emp Example of Auto shift controller lt When Auto shift is not used gt lt When Auto Shift is used gt o SSR Increase of primary Cee iat b EN ii Increase of primary A Normal primary n oA pressure i rop of prima a a ae ressure ee Drop of primary pressure Pressure pressure Teie ry T SE ily hey p H pressure Sk I h ba WA y r H i 4 Counter AMS Hg is HYS Ty j K Timer i tree et Ti ig 4 fee Ppp Tm Bnet baie Gea i ON i 4 meter out ON Oum OFF E l i f gt OFF ee omen g H Horn koe ri ho Time Time tee M Auto sed pee Auto ie pect Tachi bi pee ulse Reference pressure Reference pressure lt Reference pressure meter Atmospheric pressure Atmospheric pressure Atmospheric pressure 0 0kPa 0 0kPa 0 0kPa Display Correction set value St 5t I 5HI n an Correction set value H95 HYS SHIn X SHI n is the reference pressure set by Auto shift input 0 Sensor controller 2 Hold function Hol d a When hold digital input is supplied it maintains the current display value and control output When hold digital input is owen supplied over 5 sec this function is appl
9. X2 It is only for the digital input option model PSMCH D X3 It is only for the RS485 communication option model PSMCH R Installation Insert this unit into a panel fasten bracket by pushing with tools as shown E 30 Autonics Multi CH Pressure and Sensor Indicator Part descriptions PSM m g a ooo x a rai 5 6 7 8 1 Display part 1 PV In RUN mode it displays the measured value of the current channel In setting mode it displays the set parameter name 2 Display part 2 In RUN mode it displays the unit for the measured value of the current channel In setting mode it displays SV of the set parameter Channel display part In RUN mode it displays the channel of the value from the display part 1 In setting mode it displays the channel of the set parameter 4 Control output indicators oo PSM4 Series has 4 channels control output indicators and PSM8 Series has 8 channels control output indicators When the output is ON the relevant channel s indicator OUT1 or OUT2 turns ON 5 M key Used to enter setting mode save SV move parameters or set preset 6 amp key In RUN mode it is used to change the currently displayed channel In setting mode it is used to change the set channel or move the digit for numerical SV key In setting mode it is used to change SV from each parameter A ke
10. copy PSM PSM 0 key for over 4 sec M key U key key pu E X Converts the set of original CH or RIE subject CH E 38 Autonics Multi CH Pressure and Sensor Indicator Digital input terminal This unit executes the set function from digital input terminal d n in parameter 2 group or communication As the below there are three functions to set digital input 1 Auto shift SHFE A Photo electric sensor B Fiber When initial pressure of the pressure sensor is changed supply auto shift digital input to correct the current pressure as a reference pressure by the changed level P e Press the A key for over 2 sec in RUN mode to check correct auto shift correction value SH n Pariroa e When not using auto shift reference pressure is atmospheric pressure 0 0kPa aaa When the channel is forced output control mode or the value is HHHH or LLLL auto shift does not operate D XWhen auto shift digital input is supplied over 5 sec initial pressures of OUT1 OUT2 for all channels are changed regardless Froximlty of the applied channel range When auto shift is set preset set range is bigger than the rated pressure range as changed initial pressure B Pressure lt Preset range after auto shift correction gt Sensor Pressure
11. A Photo electric Low limit sensor scale value B a 5 C B moog Set the display value for analog input 1VDC X Displays when input display d SP ras or DC4mA is set as 50 AL sensor MI e Set range 1999 to 9999 High limit Decimal point of set range is Oika scale value al depending on scale decimal point sensor EF r r Set the display value for analog input 5VDC position d ot setting e or DC20mA Proximit y sensor A Output 2 GET ure operation mode B v Al Al A A A sensor HLS I lt gt oita HuSa gt et narli fg a Fout f M Hysteresis Window Hysteresis Window Automatic Freezer Forced output Rotary comparison comparison output sensitivity pressure control encoder output setting control 4 G Yy Seco Socket Output type Bii 8 Parameter OUT1 output OUT2 output w DAL l Bes Normally Ogen Normally Open Set output type as normally open or controller M Hoel Normally Open Normally Closed normally closed for OUT1 OUT2 I Epo Normally Closed Normally Open Ua Auto shift 1 Cec Normally Closed Normally Closed Power applied range controller GHot B Parameter _ Set range Set the applied range to auto shift w ouk Applies OUT1 of the channel Displays when digital input terminal Counter M ok Applies OUT2 of the channel d nis set as 5HF t in parameter 2 oULA Applies OUT1 OUT2 of the channel group w ALL Applies OUT1 OUT2 of all channels Timer eParameter 2 group X Parameter 2 group is avai
12. Auto identification method Set as on Turn PSM power OFF Connect PSS 4 m Turn PSM power ON Input display ae B A rO i A 15 P 5 E m d o gt 5 L AL Select display method for measured input AJ MI Standard Scale v A Pressure type Set pressure type p S A A 7 A m i e Ea I lt I e H E H Po SH wi Po SL g LI AL u J Lon P X Displays when input Positive standard Positive low Vacuum Compound display d 5P is set m 4 as Stnd v Display unit v B Pressure Unit Positive standard kPa PA kgf cm e GF bar bAr psi P 5 MPa aPA M Positive low Pa t PA kgficm7 GF bar b Ar psi P 5 Vacuum Pa t PA kgf lcm t5F bar bAr psi PS MPa aPA mmHg AAHE Compound inHg i nHE mmH2O H20 Scale decimal A i F ii point position J Set decimal point position a S A FAAN A TA AAA for high low limit scale poe E a i ni i 2D dot oogg a gogo s gt 000g 3 aoon X Displays when aa e ens y Y bd input display d 5F M is set as 5CAL J Y E 32 Autonics Multi CH Pressure and Sensor Indicator
13. PLC etc it is available to set or monitor parameters and to transmit the data by communications Interface Application standard Compliance with EIA RS485 gt It may cause malfunction when changing parameters by Max connections 31 units address 01 to 127 front keys of PSM during connecting communications Comm type 2 wire half duplex In same communication line duplicated communication Comm method Asynchronous address is not allowed Used twisted pair cable as Comm distance Within max 800m communication cable for RS485 communications Comm speed 2400 4800 9600 19200 38400bps Comm response time 5 to 99ms Start bit 1bit fixed Data bit 8bit fixed Parity bit None Even Odd Stop bit 1 2bit Protocol Modbus RTU 1 Character fixed as 11Bit a Error and troubleshooting Error Causes Troubleshooting Err When external pressure is input while adjusting zero point Remove external pressure and re try it Erre When overload is applied to control output Remove overload LLL When applied pressure is lower than display range Apply pressure within the rated display range HHHH When applied pressure is higher than display range H H LL Auto shift correction value error Set the correct SV within the set pressure range HL Proper usage Use separated line from high voltage line or power line in order to avo
14. PSM Series Display and alarm output for pressure analog MV from up to 8 CH Features e Displays pressure and MV of analog sensor from up to 8 CH e Input range 0 5VDC 1 5VDC DC4 20mA e Auto pressure sensor model identification function only for PSS Series pressure sensor e Selectable PV display part color by output operation red green e Easy check output by output indicator of each channel e Supports Modbus RTU RS485 communication e Freezer pressure control mode e Easy wiring with sensor connector CNE Series e Power supply 12 24VDC 10 Please read Caution for your ee ee ea in operation manual before ee ee ea available soon ass A a N AA pending Integrated device management program DAQMaster You can set and monitor parameters by DAQMaster Visit our website www autonics com to download DAQMaster program user manual a Ordering information ps m 4 in 2 ontrol output No mark NPN open collector output g Digital input R RS485 communication P PNP open collector output Input V Voltage A Current Number of channels 4 4CH 8 8CH Type M Multi Channel Item PS Pressure Sensor Rated pressure range and Max display pressure Unit Standard pressure standard Po5H Standard pressure lower Po 5L
15. Y A for over 4 sec Zero point settings adjustment X2 Parameter 1 C for over 2 sec Manual return for group freezer control output Parameter 2 C for over 4 sec group for change over 2 sec X3 High peak value check 0 key X1 Whe tput operation mode os Ut is F o Ut it enters fi d X1 n output operation modefao u t is F o ut it enters force Low peak value check output control mode 0 key X2 It executes this function when more than one channel s output Auto shift correction value operation mode oUt A jis freezer pressure control F E and check its control output 2 reset is manual An X3 Press the A keys for over 1 sec to initialize high low peak value or auto shift correction value Parameter setting eParameter 1 group X Parameter 1 group is available to set for each channel RUN mode Refer to m Channel change and setting XPress the M key for 3 sec during setting parameter it saves SV and returns to RUN mode M 2sec There is no additional key operation in 30 sec it returns to RUN mode Not saved SV by the J applied and the parameter maintains before SV Parameter 1 group Dot line parameters may not be displayed by other parameter settings XH Press any one key among YA keys r Ba m Auto pressure sensor model identification When connecting Autonics pressure sensor PSS Series it sets pressure T B A model automatically RESC gt na
16. applied channel range for the set digital input function d n L L T JIL x Displays for digital input option model M The channel All channels Autonics E 33 PSM Series A Zero point adjustment applied channel range ro i F 8 r A I Set the applied channel range for zero point y adjustment to change reference pressure M The channel All channels Peak value initialization applied channel Progg _ A Set the applied ch fi k r A 1 pplied channel range for pea PEs y esl value initialization M The channel All channels Channel auto change cycle A r H B Displays the value of one channel and EL that of the next channel for the set time M automatically unit sec Energy save B Saves energy to turn OFF the front except output 5 Au E indicators when there is no operation for over 1 Mi min in RUN mode Display part 1 color Status Status i Fi B Parameter Parameter Select color of display part 1 LLor gt Normal Output Normal Output depending on output status 7 r G Red Green G r Green Red r r Red
17. ctric strength 3000VAC 50 60Hz for 1 min between power terminal and case 1000VAC 50 60Hz for 1 min between power terminal and RS485 terminal Vibration 0 5mm amplitude at frequency of 10 to 50Hz for 1 min in each of X Y Z directions for 2 hours Insulation resistance Max 100MQ Ambient temperature 10 to 50 C storage 20 to 60 C Environment Ambient humidity 30 to 85 RH storage 30 to 85 RH Protection IP65 front the others IP30 Accessory Bracket 2EA Approval C pending Weight Approx 108g approx 65g X1 It is able to select at display part 1 color EL ar in parameter 2 group X2 Do not short V and OV of sensor connector It may cause break inner circuit X3 It is only for digital input option model PSM_H_ILID X4 It is only for RS485 communication option model PSML _JLIR X5 For more information about sensor connector plug refer to G Connector Socket X6 The weight is with packaging and the weight in parentheses is only unit weight X Environment resistance is rated at no freezing or condensation OEE E 29 Autonics A Photo electric sensor B Fiber optic sensor Cc Door Area sensor D Proximity sensor 3 Pressure sensor F Rotary encoder G Connector Socket H Temp controller SSR Power controller J Counter K Timer L Panel met
18. e aU t A and input display di 5 setting S Autonics E 37 PSM Series a Functions Pressure type n t This unit is able to set measured pressure type by each channel This parameter is displayed only when input display d 5P is set as standard mode SE nd e Set range Positive pressure standard Po 5H Positive pressure lower Po 5L Vacuum pressure AEU Compound pressure CanF e When using auto pressure sensor model identification At 5 pressure type of each channel is set automatically e When changing pressure type display unit Un scale decimal point position dat high low scale value H 5C L 5C preset input value and auto shift correction value 5H n are initialized Input display d 57 Select display method for measured input e Standard mode 5t nd Displays input within the rated pressure display range by pressure type unit e Scale mode 5C AL J Displays input within the set range 1999 to 9999 of high low limit scale value L 50 H 5C The resolution of PSM is 2000 and if set range is over 2000 display value is automatically proportioned Ex When set range 1999 to 2000 is over two times of the resolution of PSM the display value is automatically proportioned When changing input display preset values are initialized Display scale function H 50 5C It displays low limit value 1VDC or DC4mA high limit value 5VDC or DC20mA of transmitted anal
19. el meter M Tacho Speed Pulse meter N Display unit 0 Sensor controller P X Before using this unit you must execute zero point adjustment 2 Press the Y A keys for 4 sec at the same time the value of display part 1 flashes twice as 000 0 and zero adjustment is complete You can set the applied channel range for this function at zero point adjustment channel range 5 in parameter 2 group e 5 0H Executes zero point adjustment only for current channel e 5AL Executes zero point adjustment for all channels Zero point adjustment 4 value forcibly 1 With opening pressure ports of pressure sensors Supplying atmospheric pressure this function is to set zero point for the current pressure display 2 PS apog Press these for 4 sec keys at atmospheric pressure Autonics If there is external pressure and executing zero point adjustment Err flashes during pressing the Switching mode power supply Q Stepper motor amp Driver amp Controller R Graphic Logic panel device T Software U Other Remove the external pressure and re execute zero point adjustment E 31 PSM Series a Settings X1 Preset 0 for less than 2 sec
20. er M Tacho Speed Pulse meter N Display unit 0 Sensor controller P Switching mode power supply Q Stepper motor amp Driver amp Controller R Graphic Logic panel S Field network device T Software U Other PSM Series PC loader port SCM US USB to Serial converter sold separately Dimensions e Panel cut out Min 65 HHA ELI l en Min 65 gt e Accessory e Bracke e Sold separately Pressure sensor Sensor connector plug PSS Series 8 type Output connector cable CNE P04 YG Flat Cable 20 wire 1 27mm SCM US AWG28 2 54mm for socket oOo unit mm 45 5 lt gt Communication converter USB to Serial converter Control output circuit eNPN open collector output ePNP open collector output a d a V ouri Load J rotection 12 24voc z x Load ouT1 F fertecion 1 OUT2 z S 12 24voc E EA T 3 OUT2 Grein t 3 x a Difinputy RS485 A4 L g RS485 B OT Tao R52 Ov X1 OUT1 and OUT2 consist as the number of channels
21. esis Window comparison output mode H4 It is available to set hysteresis mode and window comparison output mode when both hysteresis mode St 1 H95 i and window comparison output mode L o Hi GH are necessary Detection hysteresis is fixed to min display range 2 Window comparison output mode Y n Itis able to set the range for high H 1 Hi 2 low Lo La 2 limit of pressure detection level when it is required to detect pressure at a certain range Detection hysteresis is fixed to min display range Parameter Set range Min display pressure 1 o lt Max display pressure 3xMin display interval eee Lan Low value 3 x Min display interval lt Hi lt Max display pressure Min display pressure lt L o 2 SMax display pressure 3xMin display interval Low value 3 x Min display interval lt Hi 2 lt Max display pressure Pressure Hisz Lag Hi 1 to IR OUT1 N O ON Lo I Hi OFF OUT1 N C ON Lo HHI OFF OUT2 N O ON Lo c Hi 2 OFF OUT2N C ON Lo c Hi 2 OFF Time 4 Automatic sensitivity setting mode AUto Parameter Set range i This mode is to set pressure detection level to the m a E a a EE E E EE i proper position automatically It is set by applied paip i Play p pressure from two positions 5 5t 2 HAG d WE eee eee
22. git Adigit Display part 1 PV 7 Segment LED red or green Display Display part 2 7 Segment LED green method CH display part 7 Segment LED red Output display part 8EA 16EA Max input points 4EA 8EA Sensor inpu 1 5VDC 4 20mA 1 5VDC 4 20mA Power supply for sensor 12 24VDC 40mA for each channel Control output NPN or PNP open collector output eLoad voltage Max 30VDC sLoad current 100mA Residual voltage NPN Max 1V PNP Max 2V Display accuracy Hysteresis 0 1 2digit at 23 5 C Min display interval Refer to Rated pressure range Repeat error 0 1 F S min display range Response time 2 5 100 500 1000ms 5 100 500 1000ms Resolution 1 2000 Control output and display Temp characteristics 0 to 50 C 40 2 F S 2digit 10 to 0 C 0 3 F S 2digit Protection circuits Output short overcurrent protection reverse power polarity protection circuit Digital input 1 point Digital input Contact input LOW LEVEL input max 0 2V Non contact input ON Residual voltage max 1 0V OFF leakage current max 0 1mA Communi Serial Serial communication with SCM US USB to Serial converter sold separately cation RS485 4 RS485 communication Modbus RTU method Connection Sensor Sensor connector terminal CNE P04 YG sold separately Output Hirose connector 20 pin HIF3BA 20D 2 54R flat cable 20 wire sold separately terminal block Diele
23. he output OFF delay time to prevent frequent ON OFF E ikd 8 Control output 2 is utilized as alarm for error pressure H951 funit digi oordisplay range ES optic Set pressure detection level1 Set 1 and hysteresis 1 EI RE 0 lt tr aE lt 3600 unit sec m H45 i output OFF delay time ti AE for control output 1 Bee IMA display pressure lt SES 2 Mex display pressie O a a6 joor Area During the output OFF delay time E AE it delays output s pay pay p sensor after hysteresis 1 H45 1 it turns OFF the output HYSe funit digity 10 of display range F S E 3 Z D Set pressure detection level 2 5t 2 hysteresis 2 H952 A A AUto auto reset An manual reset Proximity manual auto reset A A for control output 2 SEnSOF e Manual reset A An Output maintains ON before applying the reset signal digital input or 4 after hysteresis 2 B H952 he e Auto reset AUE o Output turns OFF after hysteresis 2 H952 Control output1 and control output 2 operate individually otary di lt Manual reset AAn gt lt Auto reset Ault o gt ee fl X1 Reset signal digital input or QHA Xt Output OFF delay timelt E T on Xt Output OFF delay time k AE Socket Sta LTN Ste N lt NA A p aaa Se sa sn Seri Power ll OUT1 N O ON OUT1 N O ON a Se I HY5 OFF Se W HYS OFF 9 OUT1 N C ON OUT1 N C ON Counter St I H95 OFF St 1 H45 OFF OUT2 N O ON OUT2 N O ON
24. id inductive noise Install power switch or circuit breaker in order to supply or cut off the power The switch or circuit breaker should be installed near by users for safety Be sure to avoid using the following unit near by machinery making strong high frequency noise High frequency welder amp Sewing machine High capacity SCR unit etc When input is applied if HHHH or LLLL is displayed there is some problem with measured input check the line after power off Input line Shield wire must be used when the measuring input line is getting longer in the place occurring lots of noise Installation environment e If shall be used indoor Altitude max 2 000m Pollution degree 2 Installation category II E 40 Autonics
25. ied for all channels supply 3 Manual return for freezer control output function r E St ar For freezer pressure control when control output 2 is set as manual reset AAn it resets maintained control output 2 motore at manually by supplying digital input of manual return for freezer control output Press the K 4 A keys in RUN mode it enters E 5 parameter to set the applied channel for manual return for control nig output before executing manual return for freezer control output Bei Press the M key and it returns control output 2 manually m Hold Maintains the current output status Field th e ALL Returns all output status device e Each channel Displays only the CH which output is ON Returns output of the select CH gt For digital input option model PSMLH_ _ID it is available to set the applied channel range for digital input at digital Os input applied channel range d CH e di CH Applies digital input for the channel e di AL Applies digital input for all channels By communications the only one digital input function set at ADDRESS 400053 0034 is available E 39 Autonics U Other PSM Series a USB to Serial communication Connect Autonics communication converter SCM US USB to Serial converter sold separately to the PC load port of PSM to set or monitor parameters from PC by communications a Communications From external upper system PC
26. lable to set for each channel t Refer to m Channel change and setting Panel RUN mode XPress the M key for 3 sec during setting parameter it saves SV and returns to RUN mode gt lt There is no additional key operation in 30 sec it returns to RUN mode M i H 4sec Not saved SV by the J applied and the parameter maintains before SV Spsed Pulse X Dot line parameters may not be displayed by other parameter settings mor Parameter 2 group XH Press any one key among A keys v isplay m 0 M Sensor y controller Channel copy Copies parameter SV of one channel P B aganin sujeacn C orac Subject Sienno PSM4 1 2 3 4 1 2 3 4 ALL supply M Psm8__ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ALL a y Stepper Response time a ee s Change response time of control output and pressure display value to prevent output chattering When response time is longer the number of digital filters is increased for stable display 5Pd Wh time is the number of digital filters is i d for stable displ R nier e Set range 2 5 100 500 1000ms PSM4 5 100 500 1000ms PSM8 Logic M panel T a Digital input A network terminal function device S A A Set the function to execute by external Auto shift Hold Manual return for M 3 function function freezer control output 4 U Other y Digital input applied channel range s A Set the
27. og input from pressure sensors as the set high low limit value set range 1999 to 9999 High Low limit scale value L S H 5 parameters are displayed only when input display di 5P is set as scale mode SCAL e Factory default of low limit scale value 0000 Factory default of high limit scale value 1000 gt High limit scale value should be set over low limit scale value 3xmin display unit Ex When low limit scale is 50 set high limit scale value lt 47 or high limit scale2 53 Channel copy Parameter SV and preset values of the particular channel are able to copy to the desired channel or all channels Set original CH subject CH in display part 2 at channel copy CoP 49 in parameter 2 group When executing channel copy it copies preset values and parameter 1 group s SVs except SHat J Copied items are as below Preset values Auto pressure sensor model identification At 5 Input display d 57 Pressure type a t Display unit ini t Scale decimal point position dot Low limit scale value L 5 High limit scale value H 5 Output operation mode oUt 7 Output type nanl Auto shift correction value 5H n and zero point adjustment FE ro of the subject channel are initialized Ex Copies parameter SV and preset values of CH2 to CH3 original CH 2 subject CH 3 CH1 RUN mode Enters parameter 2 group Enters channel
28. y In RUN mode press this key for over 2 sec to enter peak value auto shift correction value parameters In setting mode it is used to change SV from each parameter Connections Sensor connector input It is recommended to use Autoncis sensor connector CNE P04 sold separately PIN No DPS Voltage input Current input 4 INPUT 3 ov N C 2 TYPE 1 V X1 Dot line parts are only for PSM8 Series X2 No 2 pin is for auto pressure sensor model identification Wire it only for using Autonics pressure sensor PSS Series sold separately J Refer to the E 26 page Hirose connector HIF3FB 20PA 2 54DSA 20 pin PIN NO 1 2 6 8 10 12 14 16 18 20 Type W Ch4 Ch4 Ch3 Ch3 Ch2 Ch2 Ch1 Ch1 DI OV ouT2 OUTI OUT2 OUT OUT2 OUTI OUT2 OUTI RS485 B PIN NO 1 3 5 7 8 1 13 15 7 19 Type 1224 Che Ch8 Ch7 Ch7 Ch6 Ch6 Ch5 Ch5 Di input VDC ouT2 OUTI ouT2 outi OUT2 OUT1 OUT2 OUTI RS485 A No 19 20 pins are sub I O pins and support digital input function DI or RS485 communication A Photo electric sensor B Fiber optic sensor Door Area sensor K Proximity sensor F Rotary encoder G Connector Socket H Temp controller 0 SSR Power controller K Timer L Pan

Download Pdf Manuals

image

Related Search

Related Contents

User Manual - Gilman Group  Troubleshooting for the Online Participant  RVR MEANDER – USER`S MANUAL  deTec4 Core Ex, 8017085  APM USB Adapter WIFI 54Mb/s  DIVISION OF LIBRARY SERVICES EndNote X7 Mac User Manual  Samsung HT-D350 User Manual  Sistema di visualizzazione Christie Velvet LED  BEDIENUNGSANLEITUNG  Brochure Catalogue  