Home

remote control - CAS Systems Limited

image

Contents

1. and the connection to the OFF terminal is disconnected When the Sensaphone relay is turned OFE a connection is made between the OFF and the C common terminals and the connection beetween the ON and C common is disconnected See Figure 1 When the Sensaphone unit is put in standby mode the relay remains in its last known state If the Sensaphone is completely shut down by removing the batteries and unplugging it from power the relay returns to an OFF state connecting the OFF terminal to the C common The Sensaphone relay is a low voltage relay Only voltages less than 30 volts AC 2AMPS or 30 volts DC 2 AMPS may be switched For higher voltages an additional high voltage relay would be required RemoteControl Addendum Always enlist the services of a licensed electrician when working with high voltages Improper wiring can cause harm to you or your property NOTE For safety reasons it is highly recommended that the unit only be used to switch low voltage signals 30 volts or less If you intend to control higher voltages you must install the unit in an NEC approved electrical panel or enclosure and have wiring performed by a qualified electrician Switching the Output using the Keypad To switch the output ON from the keypad 1 Press STATUS STATUS CONFIGURE 2 Press 6 CALIBRATE To switch the output OFF from the keypad 1 Press STATUS STATUS CONFIGURE 2 Press 3 INTERCALL TIME Switching the Output
2. SEN SAPHO N E Model 1104 08 RemoteControl Addendum Your local RemoteControl dealer Sensaphone Model 1104 1108 User s Manual Model 1104 08 Owner s Manual Addendum Sensaphone RemoteControl How to use this Addendum This is a supplement to the Sensaphone 1104 08 Owner s Manual Review the entire manual before reading this addendum This addendum does not explain the Sensaphone setup configuration or operation The purpose of this addendum is to instruct you on the use of the remote control functions of your Sensaphone in order to turn on or turn off devices such as any low voltage device a high voltage relay or even an X10 device utilizing the X10 Powerflash module not included Sensaphone 1104 08 RemoteControl Feature A 1 The Sensaphone 1104 08 RemoteControl allows you to monitor and check on the status of your facility from any cellular or ordinary telephone The Sensaphone 1104 08 RemoteControl also allows you to turn a device on or off using the 1104 08 keypad or using your touch tone telephone You can also inquire about the status of the device during a voice status report This Sensaphone contains a relay contact on the rear of the unit See Figure 1 The relay contact supports both a normally open and a normally closed contact commonly referred to as a double throw relay When the Sensaphone relay is turned ON a connection is made between the ON and C common terminals
3. d up to date SENSAPHONE INC assumes no responsibility for the results of errors beyond its control SENSAPHONE INC also cannot guarantee that changes in equipment made by other manufacturers referred to in this addendum will not affect the applicability of the information herein Addendum 2002 by Phonetics Inc Written and produced by SENSAPHONE INC Please address all comments on this publication to SENSAPHONE INC 901 Tryens Road Aston PA 19014 www sensaphone com Sensaphone is a registered trademark of Phonetics Inc Touch Tone is a registered trademark of AT amp T A 5
4. over the Telephone 1 Call the Sensaphone When the unit answers it will begin reciting a status report At any time during the call press a touch tone The unit will respond with OK The Sensaphone is now ready to accept touch tone commands 2 On your phone press 6 to turn ON the output The Sensaphone will respond ON j A 2 Sensaphone Model 1104 1108 User s Manual 3 Press 3 to turn OFF the output The Sensaphone will respond OFF This initiates a full recitation of the Status Report At the end of the status report the Sensaphone will say Number five On Off for the Model 1104 RemoteControl and Number nine On Off for the Model 1108 RemoteControl 12 24 VAC or 12 24 VDC Power Supply 115 230 VAC 50 60 Hz NJ Ventilation Neutral Figure 1 Controlling a Ventilation Fan RemoteControl Addendum Controlling Lights or other devices with Sensaphone Using X10 technology you can remotely activate any electrical device or appliance in your home through your Sensaphone X10 technology is a suite of control modules that plug into your existing electrical outlets and transmit coded signals to lamps lights and appliances to turn them on or off See Figure 2 r Powerflash Lamp Light Module Module Figure 2 X10 Lighting Control Setup Sensaphone supports these devices through use of the popular X10 Powerflash relay interface To lea
5. rn more about this technology consult X10 products on the web at www x10 com or visit your local electronics shop such as Radio Shack Such applications may include turning on a lamp or exterior lights remotely from your cellular telephone when arriving at your cottage or cabin late at night Or you can use the X10 Powerflash Module set to momentary contact in conjunction with the X10 Universal Module to remotely control your electric garage door opener over the telephone an ideal way of letting in your cottage or cabin service personnel without being on site You may also use the X10 technology to send the ON OFF signal to a furnace or heater if your thermostat is not easy to wire directly Finally in addition to remotely controlling devices X10 technology lets you extend the reach of certain Sensaphone sensors such as door contacts motion sensors or water sensors This is of great benefit where it is impossible to wire directly from your sensors to your Sensaphone Consult a qualified electrician or your heating professional for assistance with locating your remote sensors or contact your Sensaphone dealer A 4 Sensaphone Model 1104 1108 User s Manual Relay Output Specifications Rated Load 2A at 30 VAC 2 A at 30 VDC Max Operating Voltage 30 VAC 30 VDC Max Operating Current 2A Max Switching Capacity 60 VA 60 W Every effort has been made to ensure that the information in this document is complete accurate an