Blazer User Manual
Contents
1. Back up time is 1 Overload 1 Remove some shorten non critical load 2 Battery voltage is too low 2 Charge battery for 8 hours or more If any abnormal situations occur that are not listed above please call service people immediately Specification INPUT BATTERY amp CHARGER TRANSFER TIME EFFICIENCY AUDIBLE ALARM VA W Nominal Voltage Voltage Range Voltage Voltage Regulation Bat Mode Freguency Freguency Regulation Bat Mode Output Waveform Charger Current DC Voltage Overcharge Protection Typical AC to AC DC to AC AC Mode Battery Mode Battery Charging Mode Overload Fault Low Battery at Battery Mode Overload Fault INVEREX INVERE INVEREX INVEREX INVEREX 500 1 1000 1 1500 1 2000 1 X 500 500VA 300 1000VA 60 1500VA 90 2000VA 12 500VA 300 OW OW 00W W 110 120VAC or 220 230 240VAC 90 145VAC or 170 280VAC Narrow Range 50 145VAC or 90 280VAC Wide Range INVERE X 1000 1000VA 600W 120VAC or 230VAC 10 18 50Hz or 60Hz 0 1 Hz Modified Sine wave 10 Amp 10 Amp 1Amp 1Amp 1Amp 24v 15ms Typical 50ms Max 6Amp 1Amp 10 Amp 1Amp 12V 10 Amp 1Amp 12V 8 Amp 24V 15V 30V gt 95 gt 80 Green lighting Yellow lighting Green flashing every 2 seconds Red flashing every 0 5 second Red lighting Sounding every 2 seconds Sounding every 0 5 second Continuously sounding PR
2. Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes Avoid touching eyes while working near batteries NEVER smoke or allow a spark or flame in vicinity of a battery Remove personal metal items such as rings bracelets necklaces and watches when working with batteries Batteries can produce a short circuit current high enough to make metal melt and could cause severe burns If a remote or automatic generator start system is used disable the automatic starting circuit or disconnect the generator to prevent accident during servicing Introduction Inverex is a DC to AC inverter with auto line to battery transfer and integrated charging system serving as an extended run UPS a standalone power source or an automotive inverter Inverex supplies power from AC power and DC source When AC cable is connected to a wall socket utility power goes to connected equipment s and or charges the battery set via charging system In UPS mode Inverex automatically convert battery energy into AC power for backing up the connected devices Features Automatic line to battery switchover Selectable Input voltage ranges High efficient DC to AC conversion minimizing energy loss Rack Tower design for flexible placement Built in enhanced charger Intelligent 2 stage charger control for efficient charging and preventing overcharge Provides overload protection Auto restart whil
3. setting for general electrical appliance If you select this mode the Inverex operating voltage in Line mode is within 170 280Vac 90 145Vac with the same output voltage The line sensitivity is higher Hence you can connect the computer systems or other precision home equipment when you select this mode B Select Wide setting to save energy If you select this mode the Inverex operating voltage in Line mode will be extended within 90 280Vac 50 145Vac with the same output voltage The Inverex is with the lower line sensitivity Moreover there will be taking a long transfer time when the Inverex transfer from Normal mode to Battery mode during power failure Hence you can connect the home equipments such as light bulb fan fluorescent tube or TV when you select this mode Caution If you select the Wide mode and connect the computer to the output of Inverex the computer may reboot if the input voltage is too low to be accepted In addition the long transfer time will happen when power failure makes the computer reboot Battery Connection Step 1 Pinch the bottom of DC input cover and Open it See Figure 4 Step 2 Following battery polarity guide located near battery terminal Place the battery cable ring terminal over Inverex s battery terminal Tighten the M5 nut Do not place anything between the flat part of battery terminal and the battery cable ring terminal or overheating may occur Caution DO NOT pl
4. EX USER MANUAL Tree AEGSES EEE MAT gt E I 28 2INVO60002 General Precautions 1 Before using Inverex read all instructions and cautionary markings on Inverex 2 the batteries 3 this manual CAUTION To reduce risk of injury charge only lead acid type rechargeable batteries Other types of batteries may cause damage and injury Do not expose Inverex to rain snow or liquids of any type Inverex is designed for indoor Do not disassemble Inverex Take it to a qualified service center when service or repair is required WARNING Provide ventilation to outdoors from the battery compartment The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment NEVER charge a frozen battery Input output AC wiring must be no less than 18 AWG gauge copper wire and rated for 75 C or higher Battery cables must be rated for 75 C or higher and should be no less than 10AWG gauge The inner diameter of the copper ring terminal which is used to connect battery cables to Inverex DC terminals should be no less than 6mm Be extra cautious when working with metal tools around batteries Short circuiting the batteries could cause an explosion For battery installation and maintenance read the battery manufacturer s installation and maintenance instructions prior to operating Personnel Precautions 1 ao
5. OTECTION F j i Full Protection Discharge overcharge and overload protection PHYSICAL 224 X 255 X 80 Dimension DxWxH mm ENVIRONMENT Operating Environment Product specifications are subject to change without further notice 0 40 C 0 90 relative humidity non condensing Less than 50dB
6. ace anything between battery cable ring terminals and battery terminals The terminal stud is not designed is to carry current Apply Anti oxidant paste to aL terminals after terminals have been torqued Figure 4 Battery Cable Connection to Inverex Step 3 Connect battery cables to your batteries e Single battery connection When using a single battery its voltage must be equal to the voltage of Inverex Nominal Input Voltage Apply to Inverex 500 1000 6 e For the user operation safety we strongly recommend that you should isolate the battery terminals before you start to operate the unit Please refer to below instruction for further information If you parallel more batteries to extend the backup time please make sure that you already use tapes to isolate the rest battery terminals before you start to operate the unit e Series battery connection When using multiple batteries in series all batteries must be equal in voltage and amp hour capacity and the sum of their voltages must be equal to the voltage of Inverex Nominal Input Voltage Apply to Inverex 1500 2000 e Parallel battery connection When using multiple batteries in parallel each battery s voltage must be equal to the voltage of Inverex Nominal Input Voltage Apply to Inverex 500 1000 extend the backup time ADD AC Connection Before having AC connection match the power requirements of connected devices with the power output of Inverex to
7. avoid overload Consult a qualified electrician and follow local code for the proper wire sizes connectors and conduit requirements Step 1 A three station terminal block is provided to make AC input connections Remove the cover plate Caution Be sure that AC source is disconnected before attempting to connect AC to Inverex Step 2 Connect the hot wire black brown of AC input cable to the HOT IN terminal Step 3 Connect the neutral wire white blue of AC input cable to the NEU IN terminal Pi Step 4 Connect the ground wire green of AC input cable D to the GND IN terminal Step 5 Tighten screws to affix wires in terminal block Step 6 Cover up the AC Input by the plastic cover ESS Step 7 Simply plug your equipment s FI into the output receptacle s Step 8 Turn on Inverex when you are using connected equipment s Figure 5 AC Input Connections Troubleshooting Problem Possible Cause Remedy No LED display 1 Battery Weak 1 Re charge battery cable and DC input connection 2 Battery defect 2 Battery replacement 3 Power switch is not pressed B Press and hold power switch Mains normal but works in inverter mode 1 AC Input is missing 1 Check AC input connection 2 Input protector is 2 Reset the input effective protector Alarm buzzer beeps 1 Overload 1 Verify that the load continuously matches the capability specified in the specs
8. e AC recovery Multi function LED indications and buzzer alarms Operation Front Panel Controls and LED Indicators Shown below are the controls and indicator lights on the front of Inverex FAULT LED INVERTER MODE LED MAINS MODE LED 0 0 0 A 8 A ly POWER ON OFF Figure 1 Front Panel Power On Off power on off button is shown as above Once Inverex has been properly installed and batteries are connected press this button and Inverex will turn on automatically and works in mains mode or inverter mode according to input AC source s status When press this button again Inverex will turn off automatically Mains Mode LED The green LED will blink or light steadily when power mains is normal Note The green LED blinks every 2 seconds to indicate that battery capacity is not full enough and battery is being charged by high rate Inverter Mode LED The Yellow LED will light when power mains is abnormal And unit will work in inverter mode Fault LED The red LED will light when fault occurs Back Panel Description Shown below are the components on the back of Inverex Figure 2 Back Panel 1 DC Input Connector Battery Terminal 2 Input Breaker 3 AC Input Connector Three station Terminal Block 4 Output Receptacle s 5 Input Voltage Range Selector Input voltage range is defined in specification chapter and output voltage is the same as input voltage in mains mode A Select Narrow