Home
The 2-tone RF Sounder, 2-in-1 wireless receiver, is
Contents
1. Parameter no 100 Enable Disable Endpoints I2 and 13 Enabling 12 and I3 or both of them means that Endpoint 12 and Endpoint 13 or both will be present on Ul Disabling them will result in hiding endpoints according to parameter set value Note that hiding endpoint has no impact on it functionality Available configuration parameters data type is 1 Byte DEC e default value 3 e 3 Endpoints 12 I3 enabled e 2 Endpoints I2 enabled I3 disabled e 1 Endpoints I2 disabled I3 enabled e 0 Endpoints 12 I3 disabled NOTE After parameter change module has to be reconfigured Parameter no 110 Temperature sensor offset settings Set value is added or subtracted to actual measured value by sensor Available config parameters data type is 2 Byte DEC e default value 32536 e 32536 offset is 0 0C e From 1 to 100 value from 0 1 C to 10 0 C is added to actual measured temperature e From 1001 to 1100 value from 0 1 C to 10 0 C is subtracted to actual measured temperature Parameter no 120 Digital temperature sensor reporting If digital temperature sensor is connected module reports measured temperature on temperature change defined by this parameter Available configuration parameters data type is 1 Byte DEC e default value 5 0 5 C e 0 Reporting disabled e 1 127 0 1 C 12 7 C step is 0 1 C Technical Specifications Power supply 110 230 VAC 10 50 60H
2. basic on off triggered at change of the input I2 state and reflecting its state up to 16 nodes Group 3 basic on off triggered at change of the input I3 state and reflecting its state up to 16 nodes Configuration parameters Parameter no 1 Input 1 switch type Available configuration parameters data type is 1 Byte DEC e default value 1 e 0mono stable switch type push button e 1 bi stable switch type Parameter no 2 Input 2 contact type Available configuration parameters data type is 1 Byte DEC e default value 0 e ONO normally open input type e 1 NC normally close input type Parameter no 3 Input 3 contact type Available configuration parameters data type is 1 Byte DEC e default value 0 e ONO normally open input type e 1 NC normally close input type Parameter no 10 Activate deactivate functions ALL ON ALL OFF Available configuration parameters data type is 2 Byte DEC e default value 255 e 255 ALL ON active ALL OFF active e 0 ALL ON is not active ALL OFF is not active e 1 ALLON is not active ALL OFF active e 2 ALLON active ALL OFF is not active Flush 1 relay module responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controller belonging to the system Parameter no 11 Automatic turning off output after set time When relay is ON it goes automatically OFF after time defined by this parameter Timer is reset to z
3. LASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_CONFIGURATION COMMAND _CLASS_ MARK COMMAND _ CLASS _ BASIC Endpoint 1 COMMAND CLASS _ ZWAVEPLUS_INFO COMMAND _CLASS_VERSION_V2 COMMAND _ CLASS MANUFACTURER_SPECIFIC COMMAND _ CLASS _DEVICE_RESET_LOCALLY COMMAND _ CLASS POWERLEVEL COMMAND CLASS _ BASIC COMMAND CLASS _SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY COMMAND CLASS METER_V4 COMMAND _CLASS_SENSOR_MULTILEVEL_V7 COMMAND _ CLASS _ASSOCIATION_V2 COMMAND_CLASS_ ASSOCIATION _GRP_INFO_V2 COMMAND _CLASS_CONFIGURATION COMMAND _CLASS_MARK COMMAND _ CLASS _BASIC Endpoint 2 12 Device Class ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE _ALWAYS_ON GENERIC_TYPE_SENSOR_NOTIFICATION SPECIFIC_TYPE_NOTIFICATION_SENSOR Command Classes COMMAND CLASS _ ZWAVEPLUS_INFO COMMAND_CLASS_VERSION_V2 COMMAND _CLASS_SENSOR_BINARY COMMAND _ CLASS _ BASIC COMMAND_CLASS_NOTIFICATION_V5 COMMAND_CLASS_ ASSOCIATION _GRP_INFO_V2 COMMAND _CLASS_ MARK COMMAND _ CLASS _BASIC Endpoint 3 I3 Device Class ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE _ALWAYS_ON GENERIC_TYPE_SENSOR_NOTIFICATION SPECIFIC_TYPE_NOTIFICATION_SENSOR Command Classes COMMAND _CLASS_ZWAVEPLUS_INFO COMMAND _CLASS_VERSION_V2 COMMAND _CLASS_ SENSOR_BINARY COMMAND _ CLASS _ BASIC COMMAND_CLASS_NOTIFICATION_V5 COMMAND_CLASS_ ASSOCIATION _GRP_INFO_V2 COMMAND _CLASS_ MARK COMMAND _ CLASS _BASIC NOTE The above list is valid for the product with a temperature sensor connected to TS terminal In case t
4. Qubino The INNOVATIVE and SMALLEST Flush 1 relay ORDERING CODE Z WAVE FREQUENCY ZMNHAD1 868 4 MHz ZMNHAD2 921 4 MHz ZMNHAD3 908 4 MHz ZMNHAD4 869 0 MHz ZMNHAD5 916 0 MHz This Z Wave module is used for switching on or off the electrical device e g light fan etc The module can be controlled either through Z wave network or through the wall switch The module is designed to be mounted inside a flush mounting box hidden behind a traditional wall switch Module measures power consumption of electrical device and supports connection of digital temperature sensor It is designed to act as repeater in order to improve range and stability of Z wave network Supported switches Module supports mono stable switches push button and bi stable switches The module is factory set to operate with bi stable switches Installation e Before the installation disconnect power supply e Connect the module according to electrical diagram e Locate the antenna far from metal elements as far as possible e Do not shorten the antenna Danger of electrocution e Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician e Even when the module is turned off voltage may be present on its terminals Any works on configuration changes related to connection mode or load must be always performed by disconnected power supply disable the fuse Note D
5. ail info qubino com Web www qubino com Date 04 06 2015 Document Qubino_Flush 1 relay PLUS user manual_V1 0_eng
6. ble add remove mode on main controller e auto inclusion 30 minutes after connected to power supply or e press service button S for more than 2 second or e press push button l1 three times within 3s 3 times change switch state within 3 seconds NOTE When connecting temperature sensor to module that has already been included you have to exclude module first Connect the sensor and re include the module Module Exclusion Reset Removing from Z Wave network e Connect module to power supply e bring module within maximum 1 meter 3 feet of the main controller e enable add remove mode on main controller e press service button S for more than 6 second or e press push button I1 five times within 3s 5 times change switch state within 3 seconds in the first 60 seconds after the module is connected to the power supply By this function all parameters of the module are set to default values and own ID is deleted If service button S is pressed more than 2 and less than 6 second module is excluded but configuration parameters are not set to default values Association Association enables Flush 1 relay module to transfer commands inside Z Wave network directly without main controller to other Z Wave modules Associated Groups Group 1 default reporting group reserved for the main controller Group 2 basic on off triggered at change of the output Q state and reflecting its state up to 16 nodes Group 3
7. efore a power failure e 1 Flush 1relay module does not save the state after a power failure it returns to off position Parameter no 40 Power reporting in Watts on power change Set value means percentage set value from 0 100 0 100 Available configuration parameters data type is 1 Byte DEC e default value 10 10 e 0 reporting disabled e 1 100 1 100 reporting enabled Power report is send push only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed independent of percentage set Parameter no 42 Power reporting in Watts by time interval Set value means time interval 0 32535 in seconds when power report is send Available configuration parameters data type is 2 Byte DEC e default value 300 300s e 0 reporting disabled e 1 32535 1second 32535 seconds Reporting enabled Power report is send with time interval set by entered value Parameter no 63 Output Switch selection Set value means the type of the device that is connected to the output The device type can be normally open NO or normally close NC Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 When system is turned off the output is OV NC e 1 When system is turned off the output is 230V or 24V NO
8. ero each time the module receive ON command regardless from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e default value 0 e 0 Auto OFF disabled e 1 32535 1second 0 01s 325385 seconds 325 35s Auto OFF enabled with define time step is 1s or 10ms according to parameter nr 15 Parameter no 12 Automatic turning on output after set time When relay is OFF it goes automatically ON after time defined by this parameter Timer is reset to zero each time the module receive OFF command regardless from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e default value 0 e 0 Auto ON disabled e 1 32535 1second 0 01s 32536 seconds 325 35s Auto ON enabled with define time step is 1s or 10ms according to parameter nr 15 Parameter no 15 Automatic turning off on seconds or milliseconds selection Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 seconds selected e 1 milliseconds selected NOTE Parameter is the same for turning OFF or ON Parameter no 30 Saving the state of the relay after a power failure Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 Flush irelay module saves its state before power failure it returns to the last position saved b
9. he sensor is not connected then following command class isn t supported COMMAND _CLASS_SENSOR_MULTILEVEL_V7 This product can be included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All constantly powered nodes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network Important disclaimer Z Wave wireless communication is inherently not always 100 reliable and as such this product should not be used in situations in which life and or valuables are solely dependent on its function Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to change and improvement without notice NOTE User manual is valid for module with SW version S1 SW version is part of P N Example P N ZMNHADx H1S1P1 Qubino K Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia Tel 386 5 335 95 00 C E m
10. o not connect the module to loads exceeding recommended values Connect the module only in accordance to the below diagrams Improper connections may be dangerous Package contents e Flush 1 relay Electrical diagram 230VAC Notes for the diagram Neutral lead Live lead Output for electrical device Input for switch push button or sensor Input for switch oush button or sensor Input for switch push button TS Terminal for digital temperature sensor only for Flush 1 relay module compatible digital temperature sensor which must be ordered separately asnpaora2 Notes for the diagram VDC VDC Output for electrical device Input for switch push button or sensor Input for switch push button or sensor Input for switch push button TS Terminal for digital temperature sensor only for Flush 1 relay module compatible digital temperature sensor which must be ordered separately Npaor2 Service button used to add or remove module from the Z Wave network Durability of the module depends on applied load For resistive load light bulbs etc and 10A current consumption of each individual electrical device the durability exceeds 100 000 switches of each individual electrical device Module Inclusion Adding to Z wave network e Connect module to power supply with temperature sensor connected if purchased e bring module within maximum 1 meter 3 feet of the main controller e ena
11. z 24 30VDC Rated load current of AC 1 X 10A 230VAC output resistive load Rated load current of DC 1 X 10A 30VDC output resistive load Output circuit power of 2300W 230VAC AC output resistive load Output circuit power of 240W 24VDC DC output resistive load accuracy P gt 50W 3 50 125 C Digital temperature sensor range sensor must be ordered separately Operation temperature 10 40 C Distance up to 30 m indoors depending on building materials Dimensions WxHxD 41 8x36 8x15 4mm package 79x52x22mm 28g 34g Electricity consumption For installation in boxes 2 60mm or 2M Weight Brutto with package Switching In case of load other than resistive pay attention to the value of cos and if necessary apply load lower than the rated load Max current for cos 0 4 is 3A at 250VAC 3A at 24VDC L R 7ms Z Wave Device Class ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE _ALWAYS_ON GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Z Wave Supported Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY COMMAND_CLASS_METER_V4 COMMAND_CLASS_SENSOR_MULTILEVEL_V7 COMMAND_CLASS_MULTI_CHANNEL_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATI ON_V3 COMMAND_C