Home
777 Tracking Unit End User Manual - Distributor
Contents
1. 18 4 6 Detault Parameletrs cue EESE teres eters LEE ERR eee 18 4 7 Combining Commande 19 5 0 UNIT SMS STRUCTURES eee rete cete e tete rai dee eae ee 21 5 1 Normal Location G Mode SMS Format T Mode 21 5 2 Hyperlink SMS Format W Model 21 5 3 Error Command Alert 21 5 4 Password Modification Successful Confirmation 22 5 5 User No Setting Successful Confirmation ssessssssssssseeeeenn 22 6 0 TROUBLE GHOOTING sse eene ene n nnnns nennen sien rnnt inest rnr sehn nnnn snnt nnns nnns 23 6 1 LED Flashes amp Relevant Device Status s nsssseneeserneetirrnsttrtettnrnsttrnnnrrnnnnrnnnnnrnnnnnt 23 7 0 CONTACT DETAILS nennen nnn nnnr seen rnnr sinn r nnns ses n nnns ERER sse n nnns nnns 24 Doc No 777 DST 2012 09 30 Rev No 1 00 Page 5 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved List of Figures Figure 1 Communication lines between the various products and 777 7 Figure 2 777 Component Illustration eueeeeeeeeieeeeeeeseeeeeseeeeene nennen nnn nint nnns nnn nnn 9 List of Tables Table 1 777 Unit Specification ecrire erre rrr nnn nnne uan nnER TERRA EI ERR RARE R EEEn ane ERR ERO 11 Table 2 LISt OF AIANIMS E 18 Table 3 Default Parametere cccccssceeecceeeeeeeeeeeeeeeeeeeeeeeeaneeeea
2. Document Title GOSAFE SYSTEMS 777 Tracking Unit End User Manual Distributor 777 Tracking Unit End User Manual Distributor Version number V2 02 Prepared by Mr Chen Approved by Mr Yang Issue date 07 31 2012 Gasafe Gosafe Company Limited Copyright 2012 All Rights Reserved Revision Sheet Rev No Change Summary Date 1 0 First Document 2011 04 27 2 0 1 Upload mode add to S mode UUM SSM TPM UPM 2011 05 16 command 2 Server port default 3032 SIP command 3 Server address domain default empty SDM command 3 1 Modified Chapter4 2 Insert SIM card 2012 07 31 2 Updated device appearance photos Note A full description of future changes will be found in the GoSafe Company Change Notes GoSafe 2012 Copy Right All rights reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of GoSafe Doc No 777 DST Rev No 1 00 2012 09 30 Page 2 of 24 Gasafe Gosafe Company Limited Copyright 2012 All Rights Reserved Abbreviations Abbreviation Description re Degree Celsius uA Micro Ampere APN Access Point Number g Gram G Gravitational Force
3. XXXX New UPW 4 digit SMS this command setting to the Message Centre Note 1 Please memorize your new password The expected reply 777 N0 12 This represents the tracking unit type 777 and the hardware software version UPW 3456 This will be your new password 4 3 2 Change Upload Mode and Reporting Interval Setting UUM This is to change the intervals or frequency between the responses and the format or type of response required Command Format 5 UUM xxxS G T Explanation PEER User password 4 digit S Command delimiter UUM Command Control Word H Command delimiter XXX SMS time interval value refer to operating cycle explanation below S Command control word interval in S econd M inute H ours A Command delimiter G Command Control Word Modes O S G or L H Command delimiter T Type of upload Text or hyperlink Refer to Message Types explanation below SMS this command setting to the Message Centre A reply with the following message UUM 30M G T in SMS Format will be received At the set intervals xxxS xxxM or xxxH the unit will respond with an asset location report If the unit operates in the real time positive work mode i e the operating cycle is set as 00S or 00M or 00H a single report message will be sent Should update location reports be required more frequently new time settings need to be submitted before the unit will respon
4. 30 20 Baud rate of extend serial port 9600 Transmit mode of extend serial port Common mode USB port mode Common mode Supper link 0 GPS Link http maps google com staticmap zoom 14 amp size 300x300 amp markers n e amp sensor false Supper link 1 LBS Link empty Phone list of SMS forwarding empty Hot line list empty Time for talking 0 0 SMS number counter 0 0 4 7 Combining Commands To save time and money when configuring the tracking unit the user can consolidate commands where more than one command is included in a request The combined command begins with the user password which is followed by a series of command requests Notes 1 The command order is flexible but the sequence within the command should follow the format below 2 The combine command function is only available to the mobile phone number of the registered user Doc No 777 DST Rev No 1 00 2012 09 30 Page 19 of 24 Gasate Gosafe Company Limited Copyright 2012 All Rights Reserved The format is Password Command word Parameter Parameter Command word parameter First command Second Command If there is duplication in the command requests the latter request will be processed if there is an error in the command the incorrect command will be discarded and the unit will only confirm the settings of the cor
5. GHz Giga Hertz GPRS General Packet Radio Service GPS Global Positioning System GSM Global System for Mobile KB Kilo Byte Km h Kilometers per hour LBS Location Based Service mA Milli Ampere mAH Milli Ampere Hour MCU Main Control Unit MHz Mega Hertz mm Millimeter MOT Motion OBD II On Board Diagnostic OEM Original Equipment Manufacturer PIN Personal Identification Number PQR Polling Query Request RAM Random Access Memory RFID Radio Frequency Identification S Second SMS Short Message System SOP Speed Over Parameter SPD Speed UAC User Alarm Cleared UNO User Number UPW User Password UTC Universal Time Clock V0 12 Software Version VOM Voice Monitoring Doc No 777 DST Rev No 1 00 2012 09 30 Page 3 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved Terms and Definitions Geo fence A geo fence is a virtual boundary around a physical geographical space A geo fence consists of a set of coordinates that define an area Fleet Manager The communications controlling authority between the tracking unit and end user OBDII Port An on board vehicle diagnostics and reporting port Threshold Pre determined minimum and maximum set of values covering a range in which an Settings alarm will be triggered when a parameter is exceeded End User The owner of the 777 tracking unit Doc No 777 DST 2012 09 30 Rev No 1 00 Page 4 of 24 D Copy
6. Unit Specification Size 55x50x25 mm ADELER OL Weight 80g IP Rating IP62 Rechargeable Battery 7 4V 180mAh Lithium ION Sleep mode lt 20UA Power Power Consumption Power Save mode 5mA Max Performance lt 300mA MCU MCU TI MSP430 12KB RAM 256KB Flash Antenna Internal Modem uBlox LEON 100 Frequency Quad band 850 900 1800 1900MHz GPRS Class 10 4 downlink 2 uplink max 5 GSM Mobile Station Class B Approvals AT amp T R amp TTE CE GCF FCC PTCRB Anatel IC China SRRC etc SIM card 3 3V SIM LBS Location Accuracy 100 to 500meters Urban 0 5 to 30kilometers Suburb Antenna Internal Receiver uBlox NEO 6M GPS amp Sbase engine Channels 50 Parallel Channels Sensitivity 162dBm Navigation update 1sec Acquisition Cold Starts 27s Aided Starts 1s Hot Starts 1s Location Accuracy 2 5 to 10meters Strong Signals 500 meters Weak Signals Sensor 3D G Force Sensor Onboard O Flash 10 000 Locations Operating Temperature 40 to 70 Environmental 2 us Storing Temperature 40 to 85 Conditions Ges Humidity 9596 Doc No 777 DST Rev No 1 00 2012 09 30 Page 11 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved 4 0 UNIT SET UP PROCEDURE The end user of the 777 will now be guided to set up and personalised the settings on a newly fitted tracking unit into
7. a vehicle also called the asset This ensures safe communication between the end user and the unit and protects valuable data against misuse by dubious people Notes 1 A mobile phone is required to perform the personalised set up In future this mobile number is the only one that will be able to manipulate default settings on the unit and message centre 2 The end user must obtain Message Centre contact details from the Fleet Manager if the default settings need to be changed afterwards 4 1 Command Settings All the commands for unit settings in this End User Manual are in the same format i e user password command content The command content is restricted to digits 0 9 English characters a z and or A Z and or common punctuations The comma is used as a Command separator amp information separator The colon is used as 1 Separator between the information symbol and parameters of upload information OR 2 Separator between a command and a parameter when the device responds to a command The semi colon is used as 1 Parameter separator OR 2 Separator between a command and parameters when sending a command we Beyond these characters the unit will not be able to recognize any commands and therefor ignore such request No response or warning will inform the user of this fault The commands are not case sensitive 4 2 Set User Number Every user of the 777 will receive a User Number UNO from the Fleet Manager
8. ain features ON or OFF it can be done by using a mobile phone Furthermore error reports also known as alarms will be automatically send to the end user on engine RPM Fuel Consumption Temperature and error codes down loaded via the ODBII port The illustration below provides a basic view of the communication lines between the various products involved r PC S OEM Manager authority SB l lt gt 9 SMS mobile terminal User authority DEV ICE Manager authority 1 GPRS server Sr Manager authority SMS SMS server UDI GPRS T Figure 1 Communication lines between the various products and 777 The default settings that can be manipulated by the end user which should be agreed prior to the installation between the manager and the end user are Password setting and changes User mobile phone number setting and change Alarm reporting intervals Speed alarm settings and enable disable Movement settings and enable disable VVVVV Doc No 777 DST 2012 09 30 Rev No 1 00 Page 7 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved Voice monitoring enable and disable Clear alarms Location polling Voice monitoring enable and disable Clear alarms Location polling VVVVV 1 1 Purpose The purpose of this document is to provide guidance to the end user to understand the various settings of the pre configured 777 tracking unit 1 2 Scope The document co
9. and this forms part of the service provided when the unit is procured The end user is required to provide a mobile number to the Fleet Manager which will be used to link the end user by means of a mobile number and the tracking unit by means of the UNO One UNO can be linked to mean tracking units 4 3 Creating your First Password It is recommended that the end user change the factory set password to your own personalized one as soon as possible A 4 digit password is chosen between the digits 0 9 To create a personalized password use your 4 digits e g 5678 of choice and send the following command See paragraph 4 Note 1 1234 UPW 5678 tothe Fleet Manager Centre See paragraph 4 Note 2 Explanation 1234 Factory Password UPW Command Word 5678 Your new personalized password Doc No 777 DST 2012 09 30 Rev No 1 00 Page 12 of 24 amp nucsol ec Copyright 2012 Gosafe Company Limited All Rights Reserved Notes 1 Please memorize your New Password and wait for the confirmation by SMS that your password modification was successful 2 The system can only process the command if there is a UNO registered by the Fleet Manager 4 3 1 Modify User Password UPW Should it become necessary to change your password for whatever reason follow these steps Command Format v o UPW XXxx Explanation EE Old UPW 4 digit j Command delimiter UPW Command Control Word A Command delimiter
10. command is 1234 SPO O The expected reply 777 N0 12 This represents the tracking unit type 777 and the hardware software version SPO 1 Parameter is enabled or 777 N0 12 This represents the tracking unit type 777 and the hardware software version SPO 0 Parameter is disabled 4 3 4 Enable Disable Over Speed Alarm SOP This is to change the default speed limits The range of the settings varies between 0 km h and 255 km h The alert speed threshold must be smaller than the over speed alarm threshold Doc No 777 DST 2012 09 30 Rev No 1 00 Page 14 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved Command format EE SOP Alert Speed Alarm Speed Explanation RON User password 4 digit j Command delimiter SOP Command Control Word Command delimiter Alert Speed Set the speed in KM H Default setting 80 km h Command delimiter Alarm Speed Set the speed in KM H Default setting 100 km h SMS this command setting to the Message Centre After receiving this command a reply with the following message SOP Alert speed alarm speed will be issued The Alert Speed is the speed when the tracking unit is activated once the vehicle exceeds the lower set speed limit and will respond with a single audio warning alert Once the vehicle exceeds the Alarm Speed or upper speed limit the unit will send alarms at the default set intervals 2 secon
11. ction Temperature Power Device Name and Version Mobile Country Code Mobile Network Code Location Area Code Cell Identity Temperature Power Device Name and Version Google Map Link Temperature Power Device Name and Version http m maps yandex ru 1l 116 3875 39 949328 amp pt 116 3875 39 949328 amp z 12Yandex Link TMP 25 6C PWR 12 5 Unsuccessful Located Gosafe 777 V0 10 MCC 460 MNC 1 LAC 517A CID 1FB1 TMP 25 6C PWR 12 5 5 3 Error Command Alert Gosafe 777 V0 10 Error command Temperature Power Device Name and Version Mobile Country Code Mobile Network Code Location Area Code Cell Identity Temperature Power Doc No 777 DST Rev No 1 00 2012 09 30 Page 21 of 24 Gosafe Company Limited All Rights Reserved 5 4 Password Modification Successful Confirmation Gosafe 777 V0 10 UPW 5678 5 5 User No Setting Successful Confirmation Gosafe 777 VO 10 UNO 8613912345678 Doc No 777 DST 2012 09 30 Rev No 1 00 Page 22 of 24 Goaosafe Gosafe Company Limited Copyright 2012 All Rights Reserved 6 0 TROUBLE SHOOTING 6 1 LED Flashes amp Relevant Device Status An external flashing LED light next to the USB port reflects the operational status of the unit The LED will flash at 8 sec intervals to indicate the GSM and GPS operational status There is a short interval between each flashing cycle first the GSM then followed by the GPS status To check the statuses
12. d accordingly Doc No 777 DST 2012 09 30 Rev No 1 00 Page 13 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved Operating Cycle xxxS Seconds upload range 30 900 seconds xxxM Minute upload range 15 59 minutes xxxH Hour upload range 1 240 hours Work Modes O Cancel Upload G If there is GPS data send GPS based location If not send GSM base station LBS data S Always update with GSM base station LBS L Unit replies at the set intervals for voice monitoring Message Types T Text format SMS W Text format with hyperlink SMS with hyperlink of Fleet Manager Platform Example 1234 UUM 30S G T The expected reply 777 V0 12 UUM 30S G T 4 3 3 Enable Disable Over Speed Alarm SPO This is to activate or de activate the over speeding alarm feature Command format xxx spo M Explanations TEER User password 4 digit Command delimiter SPO Command Control Word Command delimiter M Parameter 1 Enable 0 Disable SMS this command setting to the Message Centre After receiving this command a reply with the following message SPO M will be issued which implies that the over speed alarm is now enabled 1 or disabled 0 In future the unit will only respond with over speeding alarms when an enabled command 1 is requested Example Enable over speed alarm command is 1234 SPO 1 Disable over speed alarm
13. ds and 255 seconds Example 1234 SOP 80 100 UPW 1234 Command SOP Alert speed 80 Alarm speed 100 The expected reply 777 NO 12 SOP 80 100 4 3 5 Enable Disable Movement MOT This is to activate or deactivate the asset movement feature Command format MOT M Explanation GEES User password 4 digit A Command delimiter MOT Command Control Word A Command delimiter M Parameter 1 Enable 0 Disable SMS this command setting to the Message Centre After receiving this command a reply with the following message MOT M will be issued which implies that the movement alarm is now enabled 1 or disabled 0 In future the unit will only respond with a movement alarm when an enabled command 1 is requested Note The unit will automatically respond with a single location SMS to the end user once it senses any asset movement Once the vehicle stops the unit will start a countdown sequence and after a 60 minutes uninterrupted stationery period will the unit responds to a movement Doc No 777 DST 2012 09 30 Rev No 1 00 Page 15 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved The expected reply Enable SMS upload when movement trigger command is 1234 MOT 1 Disable SMS upload when movement trigger command is 1234 MOT O 4 3 6 Set Voice Monitoring Number VOM This is to activate or de activate the voice monitoring feature on t
14. eeeseeeeegseeesaneeeeeeeeeaaeeseaneeeaeeeeennnees 19 Table 4 LED Status Reporting ccceseecseeeeesseeeeeeeeeneeeeeseenenseeeeaseeeeaseeeeseeeeaseeeeaseeeeeeeeeaseneeasents 23 Table 5 LED Fault Reporting 2 ce ege 23 Doc No 777 DST 2012 09 30 Rev No 1 00 Page 6 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved 1 0 INTRODUCTION This new tracking unit is designed by the Gosafe Company Limited and the Connect amp Go concept of the 777 enables the unit to interface with an OBDII diagnostic port of the vehicle which provides real time performance parameters on the engine as well as driver behaviour While the 777 is plugged into the ODBII port power to the tracking unit is received from the vehicle electrical system The 777 is available from established distributors who are involved in the asset tracking and recovery business No configuration or installation of any components is required by the end user as this forms part of the distributor s service who acts as the Fleet Manager A set of default parameters which may or may not satisfy the client s needs are loaded by the manager during the fitment of a unit into an asset By means of a mobile phone the end user can change some default settings on the tracking unit to satisfy unique requirements within a set range This should be agreed upon between the manager and the end user Should the end user require switching cert
15. ent sensor manages the power to the unit when an asset is stationary for long periods The 777 is fitted with the latest available GPS uBlox modules and use Assist GPS A GPS technology to connect the unit faster and more accurately Doc No 777 DST 2012 09 30 Rev No 1 00 Page 8 of 24 s Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved Figure 2 illustrates the complete 777 tracking unit which is installed into your asset Figure 2 777 Component Illustration Description Illustration Unit OBDII plug to connect with vehicle port Rear View with USB port and microphone USB Port MIC Complete Set with USB Cable Doc No 777 DST Rev No 1 00 2012 09 30 Page 9 of 24 D Copyright 2012 Gasate Gosafe Company Limited All Rights Reserved 2 0 KEY FEATURES The main features of the 777 are gt Real Time Location Mobile Map Location Latitude and Longitude Location gt GSM Base Station Location LBS Technology gt Convenient GSM Mobile Control Easy to use SMS Communication Mode Internal Movement Sensor for better power management gt Internal backup battery for Device disconnection notification gt Internal memory for the data buffer Doc No 777 DST 2012 09 30 Rev No 1 00 Page 10 of 24 Gasafe Gosafe Company Limited Copyright 2012 All Rights Reserved 3 0 UNIT SPECIFICATIONS Table 1 777
16. ght 2012 All Rights Reserved 4 5 Alarms The unit transpond alarms when certain conditions or parameters are triggered The expected messages to receive when the unit is in the alarm state are listed in table 2 Table 2 List of Alarms SMS Received Explanation 777 V0 12 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E113 428606 SPD Okm h 0 Alarm Power Off Ignition Off 777 V0 12 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E113 428606 SPD Okm h O Alarm Over Speed Over Speed 777 N0O 12 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E113 428606 SPD Okm h O Alarm Moving Moving When the movement sensor is enabled 1 an alarm is triggered by the movement sensor as soon as the vehicle gets in motion 777 NO 12 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E113 428606 SPD 0km h 0 Alarm Geo Fence Geo Fence The format provided are just an example from GoSafe Company Every Fleet Manager s platform is unique and may differ from this 777 NO 12 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E113 428606 SPD Okm h O Alarm Anti Jamming Anti Jamming This alarm appears when the anti jamming feature is enable and someone uses a GSM jammer near the unit Alarms This depends on the Fleet Manager s platform and the alarm reporting format for e g Temperature RPM Fuel Consumption and ODBII error codes readings Note The user can use the UAC command to clear user ba
17. he tracking unit Command format kk kk VOM YYXXXXXXXXXXX Explanation TART User password 4 digit P Command delimiter VOM Command Control Word Command delimiter YYXXXXXXXXXX Registered telephone number of end user Refer to paragraph 4 note 1 SMS this command setting to the Message Centre After receiving this command a reply to the number listed in the command YYXXXXXXXXXxX will be issued The user will then be able to listen to conversations inside the vehicle cab without the knowledge of the driver When the unit is busy a SMS VOM BSY will be send and the request needs to be resubmitted Example 1234 V 0M 86123456789 The expected reply 777 V0 12 VOM 123456789 4 3 7 Location Poll PQR There are two methods to poll the location of the tracking unit 1 By sending PQR SMS to the unit KKK PRQ Explanation K User password 4 digit j Command delimiter PRQ Command Control Word SMS this command setting to the Message Centre Example 1234 PRQ The expected reply 777 N0 17 PRQ The unit will respond with the location information after the first GPS data update is received 777 N0 17 Doc No 777 DST Rev No 1 00 2012 09 30 Page 16 of 24 Gasate Copyright 2012 Gosafe Company Limited All Rights Reserved GPS 5 67 UTC 11 05 11 06 47 N23 164367 E113 428548 SPD Okm h TMP 37 8C PWR 10 5V Notes 1 N North E Eas
18. please count the LED light flashes and compare it to the table below Table 4 LED Status Reporting Status LED Flashes Device Power on GSM module ON but unregistered LED ON 1 sec 1 flash at the beginning of each flash cycle GSM module ON and registered 2 flashed at the beginning of each flash cycle GSM module OFF No flash at the beginning of each flash cycle GSM module on and registered 3 flash then GPRS connection GSM module on and registered 4 flash then TCP connection GPS module ON but haven t located 1 flash after interval behind GSM status flash in each flash cycle GPS module ON and located 2 flashes after interval behind GSM status flash in each flash cycle GPS module OFF No flash after interval behind GSM status flash in each flash cycle The unit also uses the LED flashes to indicate an error during the following situations Device Error SIM card funds depleted GSM network cannot register During any of the above errors the LED light will come ON for 1 sec and then flash quickly To assist with trouble shooting errors the user can count the quick flashes of the LED and compare it with the table below Table 5 LED Fault Reporting Error Details LED Flashes Solutions GSM module Communication Error 1 flash Power OFF Check GSM module power supply and communication SIM card Error 2 flashes Power OFF Check
19. rect commands No error warning will be given If all the commands are in error an alarm will be sent All command settings except for the User No setting command are controlled by the user Any mobile phone type can be used to communicate Example 1234 UUM 30M G T UPW 1234 Doc No 777 DST Rev No 1 00 2012 09 30 Page 20 of 24 Gasate Gosafe Company Limited Copyright 2012 All Rights Reserved 5 0 UNIT SMS STRUCTURES The SMS and hyperlink formats for every Fleet Management Platform is unique and should be obtained from the specific fleet manager Below the GoSafe fleet management platform format details 5 1 Normal Location G Mode SMS Format T Mode Successfully Located Gosafe 777 V0 10 GPS 3 56 LTMO08 00 11 24 10 02 54 N23 9 8329 E113 25 7149 Speed 1km h 39 TMP 25 6C PWR 12 5 Unsuccessful Located Gosafe 777 WO 10 MCC 460 MNC 1 LAC 517A CID 1FB1 TMP 25 6C PWR 12 5 5 2 Hyperlink SMS Format W Mode Successful Located Google link Gosafe 777 VO 10 http maps google com staticmap zoom 14 amp size 150x150 amp markers 39 9493 116 3875 amp sensor false TMP 25 6C PWR 12 5 Successful Located Yandex link Gosafe 777 WO 10 Device Name and Version Satellites Connected amp Time used for Location secs Specific time zone and Location time based on specific time zone Latitude in degree minute format Longitude in degree minute format Device speed and Move Dire
20. right 2012 Gasate Gosafe Company Limited All Rights Reserved Table of Contents RUM Usedom KREERET 7 I nani oo E HEP 8 Eoo s T 8 1 9 Product Description EE 8 2 0 dqddslse abet 10 3 0 UNIT SPECIFICATIONS ssssssssssssseeeeene nennen enn nnern snnt nnnr inen nnne sinn rines snnt rte sene n nnne nn 11 4 0 UNIT SET UP PROCEDURE ssssssssesssssessrrssssrnesertrntettnntsttnntstttnntttenntetrnntetttnnnttnnnnttennnetn nesen e 12 4 1 Command Settings ccccceccccccccecceeeesseceeeeeeecaeeeeseececeeeeeaeseeeceeeesesseaaseeeeeeeeessaaaaeeeeeeeeeeseaes 12 42 Set User Numbefiibhh esee BOO b De oe E Ert EEN EEE EFTER EE EE e EP pepe FREE PV Ed 12 4 3 Creating your First Password enne ennt nnne 12 4 3 1 Modify User Password UPW nennen nnns 13 4 3 2 Change Upload Mode and Reporting Interval Setting UUM 13 4 3 3 Enable Disable Over Speed Alarm PO 14 4 3 4 Enable Disable Over Speed Alarm OP 14 4 3 5 Enable Disable Movement MOT 15 4 3 6 Set Voice Monitoring Number VOM nnns 16 4 3 7 Location Poll PQB aired tod dotar eco edes 16 4 3 8 Clear Alarm AC 17 4 4 Pending Commande ssssssseessekneseretttettnrttttntstttntntttnttettnnnsttnntstEnnsttEnnnnEnnnnnn neeem ennen 17 LM dude C
21. sed alarms 4 6 Default Parameters The unit is set to the following default parameters When the unit is powered up for the first time the unit will default to the following parameters and wait for user or server commands to update The user will be able to manipulate the parameters marked as Y whilst the Manager OEM can change any default parameter Doc No 777 DST Rev No 1 00 2012 09 30 Page 18 of 24 Gosafe Gosafe Company Limited Copyright 2012 All Rights Reserved Table 3 Default Parameters Description Parameter User number EMPTY SMS center number EMPTY PIN code of SIM 1234 APN list APN list of China only User password 1234 User upload mode 30M G W Manager phone number empty Manager upload mode 30M G T Server IP or domain name domain name empty IP 114 142 154 28 TCP port 3032 UDP port 3032 TCP channel upload mode mode 0 60S G B UDP channel upload mode mode 0 60S G B Package number per TCP upload 1 Package number per UDP upload 1 Percentage of data buffer per TPC 50 upload Percentage of data buffer per UDP 50 upload Over speed 80 100 Enable disable over speed alarm Disable Enable disable vibration sensor Disable Enable disable phone roaming status Enable test Enable disable anti jamming Disable Time zone 0 00 Vibration sensor parameter 10 10 30 Anti jamming parameter
22. t W West and S South 2 Anegative represent Western Time zone a positive represent Eastern Time zone 2 Bycalling the Unit Number and hang up after the first ring the device will send back the GPS location to the user mobile phone Note The Unit Number is the contact number of the SIM Card installed by the Fleet Manager in the tracking unit The expected reply 777 NO 17 GPS 5 67 UTC 11 05 11 06 47 N23 164367 E113 428548 SPD Okm h TMP 37 8C PWR 10 5V 4 3 8 Clear Alarm UAC This is to clear an alarm response from the unit to the end user Command format KKK UAC Explanation ZE User password 4 digit j Command delimiter UAC Command Control Word SMS this command setting to the Message Centre After receiving this command a reply with the following message UAC is issued This implies that the alarm has been cleared Example 1234 UAC The expected reply 777 N0O 12 UAC 4 4 Pending Commands In the event the user sends commands and the unit is in the sleep mode the unit will not process the commands During the next wakeup session the unit will download and process the commands within the first minute A message will be send to the user afterwards to confirm the reception of the commands There after the unit will receive and process the commands in real time and reply accordingly Doc No 777 DST 2012 09 30 Rev No 1 00 Page 17 of 24 Goasafe Gosafe Company Limited Copyri
23. vers the following aspects Section 2 Key Features A short summary of the key features of the 777 product is provided Section 3 Unit Illustration Photos illustrating the various components of a complete 777 product is provided Section 4 Unit Specification The 777 physical electrical and environmental performance specifications are provided Section 5 Unit Default Change Procedure A step by step procedure is given to enable the user to change the default settings Section 6 Unit SMS Structures The SMS reporting structures are shown to assist the user with the interpretation of commands received Section 7 Trouble Shooting Basic fault diagnostic procedures are included to assist the user when problems are experienced Section 8 Contact Details The contact details of the GoSafe Company Ltd in China for support are included 1 3 Product Description The new 777 tracking unit makes use of the Global System for Mobile GSM communication networks and the Short Message Service SMS technology to provide accurate real time Global Positioning System GPS data to locate assets Additional information such as temperature fuel consumption speed and voice monitoring is available on a vehicle The 777 unit houses a GSM modem GPS receiver control PCBA microprocessor power circuitry etc A separate RFID tag is provided to the end user to be left in the vehicle when it goes for routine services An internal movem
24. whether the SIM card installation is good and the PIN is disabled Cannot register at GSM network 3 flashes Check whether the SIM card is expired and or GSM signal strength GPS module Error 4 flashes Power OFF Check GPS module power supply and communication SMS Sending Error 5 flashes Check whether there is SIM card SMS center setting error and or SIM card expired Can t use GPRS 6 flashes Check whether the APN is correct and the SIM has a GPRS function or not TCP connection Error 7 flashes Check if the server is normal Unknown Error 8 flashes Switch power OFF then power ON reset If the error persists please contact your nearest GoSafe representative Doc No 777 DST Rev No 1 00 2012 09 30 Page 23 of 24 Gasate Gosafe Company Limited Copyright 2012 All Rights Reserved 7 0 CONTACT DETAILS Gosafe Company Ltd in China Tel 86 20 6667 9696 Fax 86 20 6667 5900 Enquiry info gosafesystem com Support support gosafesystem com Online Support gosafe support skype Doc No 777 DST Rev No 1 00 2012 09 30 Page 24 of 24