1. 2 1 Temperature 2 3 J Temperature 3 Temperature 4 Analog ground common NTC 8 ZJ Buzzer out active pull to GND GND felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OSENSIO rie SC 1 User Manual Connector C2 Pin Description 1 J J Digital input 1 internal pull up 2 9 Digital input 2 internal pull up 3 Digital input 3 internal pull up 4 J JA Digital input 4 internal pull up 5 Jo Relay driver 1 active pull to GND 6 Relay driver 2 active pull to GND 8 J J J Relay driver 4 active pull to GND 9 HIRV supply voltage Connector C3 Pin A2 ZJ jDescipio RS485 positive 0 0 0 0 RS485 positive RS485 negative GND Note The internal IR receiver is channel 3 in SW 3 1 1 Comm connector The communication connector has pins for RS232 port A and B Description AUX input do not connect AUX output do not connect T 12V supply voltage GND Port B RX Port B TX Port A RX Port A TX felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc SENSIS me SC 1 User Manual 3 1 2 Ethernet connector The Ethernet connector is standard 4 wire Pin Description i 8 ES i STOO OOOO C 8 me 77000000 INNEN GN 8 0 HN 00000 Note The power connections here are for supplying 12V through the Ethernet cable
2. as an option This is not PoE i e not compatible with IEEE 802 3af which is 48V The connections are not compatible with certain Apple products i e Apple AirPort in which case only connections to pins 1 2 3 6 must be used felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OSENSIO rie SC 1 User Manual 4 Power Supply The power supply is connected to screw terminals C3 Pin 6 12V and 9 GND The SC 1 itself will draw less than 150 mA from the power supply but each relay coil driven by the SC 1 may add 20 200 mA to the total o00000000 I000000000 T4T2T3T4TsTeG4B G D Enos SC 1 sens Sens SC 1 adapt control 10 PsGaln lo li VeRoRwGn RS232 12V 220V pcox V V asio MODEL DR 30 12 T v INPUT 100 240VAC 1 1A A p 50 60Hz OUTPUT CAU TION or use on m IE 5 felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OSENSIO rie SC 1 User Manual 5 Network The SC 1 is connected to a switch router with a normal Ethernet patch kabel o00000000 l200000000 T4T2T3T4 T5 TeG4B G D D2D3D4R R2R3R4V sci sensio sc adapt control solutions DOOOOOOOO TUE TT felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc 3sensio tie SC 1 User Manual 6 Temperature probes Temperature probes Sensio type are connected to SC 1 between terminals T1 T6 C1 Pin 1 6 and analog ground C1 Pin 7 CC Svart Hvit oe 609000000 o00000000 T T2T3 TAT amp TeG4B G D4D 2Da3D4R4 R2R5
3. R4V SC 1 DEn SC 1 adapt control solutions P5Grl lo li VRRnrGn RS232 12V Eth oo00000000 RU TT The Temperature probes are of type NTC with nominal value of 50 KOhm and Beta value of 3950 The probes are internally connected in a bridge with 47Kohm as the other leg Different NTC values are possible but should not be far away from the default values to maintain the accuracy The Telnet commands for changing the NTC configuration resistance and Beta is ntcr and ntck see FW manual felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OSENSIO rie SC 1 User Manual 7 Potential free contact inputs Potential free contacts are connected to the SC 1 between terminals D1 D4 C2 Pin 1 4 and digital ground Gn C1 Pin 9 The terminal are internally connected to 5V with a 10 KOhm resistor 0 5 mA contact current The input terminals are voltage limited through a 10KOhm resistor clamped to GND or 5Volt with zenerdiode This means the input terminals may be connected to a voltage source and the tripping point will be around 2 Volt oecocooo9 600000000 T T2T3T4T5TgGaBzG D1D2D3D4R1R2R 3R4V sc S3sensio sc adapt control solutions PGi lo li VMRJR G RS232 12V Eth QWDOOOOOO felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OSeENnSI we SC 1 User Manual 7 1 Pulse power meters Power meters with pulse output SO are also connected to the D1 D4 terminals The pulse output
4. S sensi meSC 1 User Manual Document Date Author Revised Approved SC 1 Ver 1 4 User Manual doc 11 02 2013 Tore SC 1 User Manual PT T2 Ts Ta Ts T6 Ga Bz Gn Di D2 D3 D4Ri R2 R Rave J e adapt L1SIO If www sensio no C RoHS Sn 2 000 4 G 5 R2 6 T2 7 R1 S TI1 e In Io li V Rp RmGn mRs2 32 abe Contents 1 TNCFOGUCHON Mere S 2 2 Physical VIeW unas viae PERRO OV c I ER CRURA GEO wRERLDR R ARO MI VTE RRRHR 2 3 COnnecELoFs soia dapi DOR CROCI ORG REO D BEER DREW RN ERR RD RR PN RON RR KR RU RACER RC RR 3 3 1 1 Sessione MERE EE MT TTIPITPETM 4 354 2 Ethernet connector assbessequassshisssd tapas utinnvadsri aditus air Edd Hin VERRE MC ER DF RM DER PNE 5 4 Power Supply oss vERIDER DIE RERO ERROR ELA NOR UA HORE CERCA AUR RR ER EUR E ERU DTE RUE DR 6 5 INGE 6 p ONT TTE UU c uPmPYT TM 7 6 Temperature DFODOGS isis virEk EE VERREM ENS ERE NARANVEVS aaa 8 7 Potential free contact IDDUES ueessasaus aca eR REOR RN ERN GUN RADAR R8 9 7 1 PULO DOWER THOEOTS iorosexaauigdademsned aded oru Xo DESCR CHN UE EN CN TR ERE a Da ODE OE 10 8 FAY cocus EFRREEXEMENEXE ERE RIMDRINCEEEPEERNERNENCUNEHUDUN EUN II QUEIR RUERRER VER REGN SK NM UE KEN ME 11 9 Connecting IR sensors and emitter ec eoee ee eene nnns 12 9 1 IR sensor standard type with positive going pulse seen nnne 12 9 1 1 learn T 13 9 1 2 IR rece
5. channel 1 4 D o00000000 000000000 T4T2Ta3 T4 Ts TeG4B G D D2D3D4R R2R3R4V SC 1 3sensio SC 1 adapt control solutions PsGaln lo li V RRnGn RS232 12V Eth 299900000 imi TIT e o00000000 oeced e T4 T2 Ta T4 Ts TeGaBzGn D D D3D 4R R2R3R4V sc 3sensio sc adapt control solutions PsG4l lo li VNRJR4 GG RS232 12V Eth 209990000 IULII LT felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc 3sensio we SC 1 User Manual 9 1 2 IR receiver Everlight IRM8601S Connect to connector C3 Pin 1 2 3 as shown 10 Commands and programming The SC 1 is SW compatible with AHC3000 The only difference is in number of IO ports and physical configuration See AHC3000 User Manual for description felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OSeENnSIO we SC 1 User Manual 11 Specifications DIN rail 6 modules 12VDC input voltage 10V 15V 2 W Ethernet interface 1 4 IR transmitter driver variable frequency 4 relay coil open collector driver outputs 12 V relays current limited 4 NO NC switch inputs pull up 3 3V 6 channel temperature measurement input NTC Internal temperature sensor channel 7 2 serial communication channels RS232 IR code receiver optical 2 IR code receiver inputs wire
6. iver Everlight IRM86018S ceeeuueeeeuleeecee enhn nnn nnn nnn nn 14 10 Commands and programming eeeee eee e aaa nnnr nennen uua unn nnn 14 11 SDeCITICatiOns serisinin HEN RUN EAR R EMEN EM R RH ERMMERN DRE NR ON NE EENEAEONPMEEREERRME EROR ERE 15 SENSIO AS e MALERHAUGVN 25 0661 OSLO www sensio no QSENSIO ue SC 1 User Manual 1 Introduction This document describes the usage and specifications for the Sensio SC 1 Controller The controller is built in a DN rail mountable plastic box Ti T2 T3 T4 Ts T6 Ga Bz Gn Di D2 D3 D4 Ri R2 R R4 V SSS SS See sensio adapt control solutions www sensio no C RoHS SC 1 Sn 2 000 4 G 5 R2 6 T2 7 R1 T1 e Ps Gn In To Ii V Rp Rm Gn RS232 12VDC 2 Physical view The physical measurements are shown below 95 iens i T as 76 108 301 felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OSENSIO rie SC 1 User Manual 3 Connectors Pin 1 Cl Pin 1 C2 C1 C2 500000000 505000000 T T2T3T4T5TgeGaBzG D D2D3D4R R2R3R4V SC 1 O SENSIO sc adapt control solutions P5Gnln lo li V RRnGn RS232 Reset Eth Bgosssosor te TT C3 RS23 Reset Ett Pin 1 C3 Pin 1 RJ45 Internal IR receiver The connectors C1 C2 and C3 are screw connectors with 9 terminals each RS232 connector is RJ45 and Eth connector is RJ45 Between RS232 and Eth connector is the reset switch Connector C1
7. or ed one positive going pulse and one negative going pulse Internal battery backup for storage of state information during power loss Operating temperature range is 0 50 deg Celsius VVVVVV N N N N WV VV felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc
8. s are normally opto isolator outputs and the positive side collector is connected to D1 D4 and the negative side emitter is connected to ground Shown connection to type M1DC 23005 1 L1 T4T2T3 TA Ta TeG4B G D1D2D3D4R1R2R 3R4V SC 1 Osensio SC 1 adapt control solutions PsGrln lo li VRRnrGn RS232 12V Eth felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OQ SENSI ne SC 1 User Manual 8 Relay Relays are connected to the SC 1 between the terminals R1 R4 C2 Pin 5 8 and 12Volt Supply C2 Pin 9 The R1 R4 terminals are open collector pull down transistor drivers with a 300 mA current limiter PTC resistor o000000090 I000000000 T4 T2 Ta TATs TeG4Bz G D1D2D3D4R1R2R3R4V SC 1 Qysensto SC 1 adapt control solutions P5sGaly lo li VIRdJR4G RS232 12V Eth o00000000 felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc Ssensio ue SC 1 User Manual 9 Connecting IR sensors and emitter 9 1 IR sensor standard type with positive going pulse Connect to C3 Pin 2 5 6 with GND and voltage wires as shown oO00000000 2000000000 T T2T3T4T5TeGaBzG D D2D3D4R R2R3R4V sca sens lO sc 1 adapt control solutions P5Gnln lo li VRRrGn RS232 12V Eth DOOOOOOOO im TIM m signal felles Produkt SC 1 SC 1 Ver 1 4 User Manual doc OQ SENSI me SC 1 User Manual 9 1 1 IR emitter Connect to C3 Pin 2 4 with positive on Pin 4 and negative on GND channel 0 or R1 4