Home

USER`S MANUAL

image

Contents

1. Love of life begins with Rcom MARE DIGITAL EGG INCUBATOR USERS MANUAL MARU MAX 190 380 1000 Cradle Type mane Contents How to use Rcom MARU MAX 190 380 1000 1 Introduction 1 Rcom MARU Introduction 2 Safety precautions 3 Identification of Parts Introduction 4 Basic components 5 Name amp Function of Operation Parts 6 Easy Function Operation 2 Before use 1 What is an Incubation Room Before use 2 How to Install Incubation How to assemble the rotary wheel Options 3 Incubation 1 Preparation for Incubation How to Start Incubation BTEREN Incubation 2 Egg Turning Humidification How to Terminate Incubation 3 Humidity amp Air Maintenance during Incubation 3 Maintenance after Hatching Dew Condensation 4 Function Settings 1 Return to Factory Setting 14 17 2 Temperature Humidity Setting How to preserve the humidification unit part Fu nction Settings 3 How to Set Abnormal High amp Low Temp Alarm 4 How to change Centigrade amp Fahrenheit 5 Egg Turning Interval Setting 5 How to Clean 1 Disassembling and Cleaning the Incubator 18 19 6 Product Information 1 How to Replace Fuse Servicing Frequently Asked Questions FAQ 20 23 P 2 B en Product Information 2 Troubleshooting How to Clean 3 Specification A The result of Hatching and Brooding can be changed by
2. Incubation Termination d No power switch for the incubator The power cord should be unplugged to turn the incubator off after hatching Rcom MARU MAX 190 380 1000 do not need to be initialized after hatching When you need the same condition as the previous set all you need to do is to plug in your incubator 42 DIGITAL INCUBATOR 3 Humidity amp Air Maintenance during Incubation 3 Incubation Maintenance after Hatching Dew Condensation Humidity amp Air Maintenance During Incubatiron gt When hatching humidity should be relatively high to prevent the thin membrane from drying out or hardening before hatching When hatching it s recommended not to open the door often This is because if you open the door often humidity will be rapidly decreased and it will take a long time to regain the proper humidity A Incubator internal temperature is 37 C 99 5 F or more and hatching room temperature is below 28 C in that case RH70 humidity is may not be able The difference of 5 humidity value may occur from the humidity sensors difference and there are no problems at hatching gt It s very important to maintain humidity higher 1 2 days before hatching than the early and middle incubation periods Humidity requirements during incubation are RH 45 55 for waterfowl RH 40 45 for poultry and RH 35 45 for parrot in general One day before hatching all kinds of birds need about RH 65 humidity
3. 43 Water Supplement Lamp Blink with water shortage Calibrated Temp amp humidity DOWN Turning on L Lamp The light on while the left side Manual egg turning button cradle working 7 Menu Selecting Button Setting Value save Turning on R Lamp The light on while the right side Egg Turning Melody ON OFF cradle working DIGITAL INCUBATOR 1 Introduction 6 Easy Function Operation gt tEP gt or x Start Temp Default 37 5 C 99 5 F x or lt rH to the window n Default RH 4596 Humi gt 090 gt Abnormal High Temp Alarm How to Set LO Abnormal Y the Function Default 3 Low Temp Alarm C F gt ve or gt x Cels Fahr 4 Working when incubator water is empty Turning Off Humidification Pumping Motor Display during Test no working POWER IN gt rSt Cradle Horizon OLD Alignment Manual egg turning r will be done in terms of the setting 19 Horizon egg turning will be done in terms of the setting 3sec Initialization Factory Setting Forced manual Egg Turning Egg Turning Once 3 Times 4 Times or Ore Turning Turning Turning HOLD OFF on the right side both sides Repeat Push button more than 5 seconds Basic set up Turning sound ON Default Turning both sides Egg Turning ON OFF on the left side How to set the t
4. If you have any faulty or broken because of not using independent Hatcher or Brooder we do not serve you the free warranty service In other words you have to pay for the service charge To make a simple Hatcher or Brooder please refer to the our web site www Rcom co kr Please do not try to egg hatching in the incubator It makes your incubator broken or faulty and we do not give you free warranty service Please move all the eggs 1 3 days before hatching into Hatcher or Brooder d Hatcher The machine for egg hatching Operate it 1 3 days before egg hatching Rcom MARU H amp B Brooder The machine makes baby chickens or birds warm up against cold or cool environment You can set up proper temperature and humidity Rcom MARU H amp B Rcom Brooder Series As there is some difference in chick feed for each kind of bird so it s desirable to obtain useful information about the chicks before hatching Dew Condensation gt Dew condensation is natural phenomenon which can be occurred when incubator inner temperature is big different from outer temperature So water can leak from the incubator during humidification which is normal Appropriate Incubator internal temperature is between 28 C 82 4 F DIGITAL INCUBATOR 4 Function Settings 1 Return to Factory Setting 2 Temperature Humidity Setting Return to Factory Setting This function is for return incubator to factory setting a n z E
5. gt Eggs might be contaminated by chicks that hatched first gt Inspect the egg to check possibility of egg surviving Disinfect the incubator Check all settings of incubator Especially check them focusing on the temperature Review care of health of mother bird gt Check if egg turning is normal Lower temp setting of the incubator about 0 5 C 1 F ex 37 5 C 99 5 F gt 37 0 C 98 6 F gt Check if egg turning function is OFF Raise temp setting of the incubator about 0 5 C 1 F gt ex 37 0C 98 6 F gt 37 5C 99 5 F Minimize the time to store egg properly Check Temperature difference in the incubator sunlight temp of incubation room etc Mark hatching date on eggs and move them to other incubator brooder just on the marked date In case of putting in many eggs at the same time it s convenient to prepare a spare incubator available as a brooder DIGITAL INCUBATOR MARU Troubleshooting 6 Product Information www Rcom co kr diagnosis For more detail please check our website at CIRCUMSTANCE ITEMS TO BE CONFIRMED SOLUTIONS No signs of power to the incubator Temperature will not go high enough Alarm sounds with HI indication abnormal high temp Alarm sounds with LO indication abnormal low temp Humidity will not go high enough The machine makes some noise little noisy occurs from the inside of circulati
6. All our Rcom digital products of Autoelex Co Ltd are made by precision systems under strict quality control But occasionally some defective products are found on the way of their distribution If any problem occurs then please contact Autoelex service center or distributorsin your country We will do our best to solve the problems if any for you This product is designed in modular mode so for its repair if any a qualified person can replace the part concerned with ease When the fuse is damaged remove the fuse at the inside below of power connection part with screwdriver Complaint Department 82 55 337 2560 E mail Receipt Rcom Rcom co kr In case hatching rate is low When a chick hatches out earlier than expected or a deformed chick hatches out When a chick hatches out later than expected When hatching dates are so different from each egg When all chicks don t hatch out at the same time but over a long period When intending to hatching various eggs at the same time gt When the egg is an unfertilized egg gt Getting infected by germs gt Wrong incubation setting gt Health condition of mother bird gt Improper egg turning gt Setting temperature high gt Egg turning was not operating normally gt Setting temperature low Eggs stored for different lengths of time gt Diffferent incubation temperatures gt Incubation days are different so hatching rate falls down
7. For MAX 1000 Turning L and R lamp indicates which side cradle is turning Be recommended to hatched in special hatching room chickens in hatch are easily exposed to the risk of failing down or being caught in crevice to death occasionally Please don t forget to turn off the turning function at this time DIGITAL INCUBATOR d 1 Preparation for Incubation How to Start Incubation 3 Incubation 2 Egg Turning Humidification How to Terminate Incubation How to Set Egg Turning ON OFF gt MAX 190 MAX 380 Press button to change setting while pressing button Default Turning on Turning ON Lamp on Turning off Turning ON Lamp off gt MAX 1000 Turning Lamp L and R indicates which side cradle is turning Default Both side turning Turning Lamp L and on once twice 3 times 4 times Default gt MAX1000 sonsa Cr m gt m m gt 9 penne Left sid Right sid Both sid Turning OFF cradle Turning Turning Turning ON ON ON L Repeat Recommend to hatch in special hatching room chickens after hatch are easily exposed to the risk of failing down or being caught in crevice to death occasionally Please don t forget to turn off the turning function at this time Egg Turning Melody ON OFF aN Please press button over 5 seconds to turn ON or OFF egg Turning Melody Son Soff NY Humidification All kinds of bird need over RH 65 humidity during the period prior
8. Top Body 110 ASM C38 Top Body 220 ASM C1K Top Body 110 ASM C1K Top Body 220 ASM C19 C38 Bottom Plate 380 Boom Plate 38 C1K Bottom Plate 1000 over 380 cover 30 Cover 1000 C38 Front Frame BRK C38 Rear Frame BRK C38 Body Frame 190 380 C1K Body Frame 1000 C38 Frame FL 190 380 Rcom MARU 190 380 1000 PART LIST AE NMELNME C38 Rear Foam Board 380 ear Foam Boar C38 025 10 C38 Frame FR C1K Rear Foam Board 1000 190 380 B tyrofoam tyrofoam tyrofoam C38 Frame RR C38 026 10 190 380 ottom Styrofoam C19 C38 Bottom Styrofoam C1K Bottom Styrofoam 38 Crank Bar 380 19 Crank Bar 0 1K Crank Bar 1000 RCM 701 10 Rubber Foot C 38 044 10 C38 Magnet L BRK Universal Egg n Basket C38 045 10 C38 Magnet M BRK Basket Support RCM 702 10 Magnet gt SS OSHA ABS Divider no 3 C38 816 10 C38 Hinge C38 041 10 27 C38 Door ASM 190 380 C1K Door ASM e C38 A702 10 C38 Wheel ST 5 Opt 1000 ale C38 Wheel BK Option ide Foam Board 190 ide Foam Board x Partly spare parts are not on the parts list Rcom is designed for user s easy and convenient use It can be changed without notice for improvement in performance design treatment and software etc DIGITAL INCUBATOR com SELLER MANUFACTURER AUTOELEX CO LTD O Head Office Deokam 612 Juchon Gimha
9. a large numbers of factors Autoelex Co Ltd amp our distributors will not take any responsibility for Loss of eggs or pet animal lives under any circumstances such as Hatching Brooding failures User s carelessness Personal un certificated conversion alteration Arbitrary using out of the machine s purpose Electric power failure or Malfunctioning Please be sure that the machine works without any problem before placing Eggs or Pets Animals Also we strongly recommend you to read the User s Manual carefully to minimize of any failure Mark Explanation N Caution Caution mark against a fault that can cause damage trouble or failure of incubation S Prohibited aD It is necessary to keep Do not disassemble Remove the power cord from outlet Do not touch B Ground Connection for preventing electric shock Tip Tip References or useful suggestions in using Rcom product MCAUTION Warning of actions which may be dangerous or cause damage to the incubator DIGITAL INCUBATOR 1 Introduction 1 Rcom MARU Introduction Rcom MARU First of all sincerely thank you for all purchasing Recom MARU incubators It has been designed to analyze airflow from computer simulation in order to keep optimal environment inside of incubator and applied high digital technology to control automatic hatching system However to acquire top notch hatching result user s knowledge of th
10. gap because of door is not completely closed Connect silicon tube to the nipple of incubator and the other side of silicon tube should be put in the water container YA Do not place water container on the incubator It might overflow from the humidity unit GH Water in y A If you use Mineral water or Tap water for humidification the humidity unit can be broken easily because of water scales We strongly recommend you to use only DISTILLED WATER for your machine and Autoelex Co Ltd amp our distributors do not indemnify for warranty service not only if you have any problem with using mineral water regular water tab water and the like but also if you had improper management or handling for your machine In this case Autoelex Co Ltd amp our If the egg basket lean to the front side distributors will charge for your after service they can be wedged by cradle frames Sold Separately the rear brake free type wheel 2 the front brake type wheel x2 lay down cautiously the machine bracket wheel screw in seguence a for the front 2wheels assemble brake type wheel b for the rear 2wheels assemble brake free type wheel Once the assembly done put up the assembled incubator with care A when in lay down or put up incubator be careful not to be damaged DIGITAL INCUBATOR 9 1 Preparation for Incubation 3 Incubation How to Start Incuba
11. is not placed too cold circumstances gt When you turn OFF incubator and then turn on In case of setting high humidity gt Check if you did not place the water container on the incubator gt Check that the incubator placed on inclined surface gt Check if it is Dew condensation gt Connect the cord again gt Check the main socket with any other electric appliances gt Try to insert to another outlet gt Set the temperature as required gt please remove moisture gt Please put the water tank on the floor and use gt Adjust room temperature 28 C 82 4 F gt Install incubator without the direct rays of sun gt Return incubator to factory setting Refer to page 14 gt Adjust room temperature 28 C 82 4 F Place thermometer inside of incubator and check if setting temperature is correct gt please remove moisture gt Please put the water tank on the floor and use gt Supply water Check if silicon tube is blocked gt Set the humidity again as required Clean the humidification unit Refer to page 18 19 Press Thermostat knb of S W in humidification unit Refer to page 18 19 Remove power and then open maintenance cover to clean the FAN for air circulation Refer to page 19 gt If you need to turn the eggs you can manually re start egg turning gt Adjust room temperature between 28 82 4 F Dew condensation is normal Itis normal Place w
12. next stage abnormal low temp setting with display LO abnormal low temp alarm for SSS N 4 aout 05 sc EB ZEN EN TEMPERATUHE HUMIDITY ij Abnormal High temperature This function gives ieee S uw 7 notice when incubator temperature is higher lt C SS than setting temperature because of abnormal DEBE 5588 ambient temperature increase EN N NY When room temperature is higher than incubator Zu temperature this function works with buzzer Here HI and temp gap are displayed alternatively Press OK button to remove buzzer DIGITAL INCUBATOR 3 How to preserve the humidification unit part 4 Function In How to Set Abnormal High amp Low Temp Alarm cl O Sett 9 S 4 How to change Centigrade amp Fahrenheit How to Set Abnormal Low Temperature Alarm This function gives notice when incubator temperature is lower than setting temperature because of abnormal SSS C ambient temperature decrease amp m 45 O TEMPERATURE HUMIDITY Adjust abnormal low temp setting with or button Default setting 3 C A So T F gt After setting required value press x button to save 7 N Then it will go to the next stage C amp F change bese aN A Sr 7 Tiny Abnormal Low Temperature LO will Y indicated on LCD 6 F The others sa
13. to hatching gt How to turn humidification off When you don t need the humidification function with your working incubator you can turn off by setting RH 19 in the humidity setting mode The mark appears on FND and the humidity function stops gt Indication of water shortage When the sensor detects low water level water empty lamp is turned on Lasting water shortage causes turning water empty lamp on blinking of humidity working lamp and alarm ringing gt How to test a pumping motor Press button while your incubator is working and then the pump motor starts working d In case of water shortage it works When the inside of the incubator is filled with water the pump motor works for 0 5 second Check motor working sound please turn off the humidity unit if the unit is empty water otherwise humidity unit will be broke or you may not no longer use the unit so please turn off the humidity unit A If you use Mineral water or Tap water for humidification the humidity unit can be broken easily because of water scales We strongly recommend you to use only DISTILLED WATER for your machine and Autoelex Co Ltd amp our distributors do not indemnify for warranty service not only if you have any problem with using mineral water regular water tab water and the like but also if you had improper management or handling for your machine In this case Autoelex Co Ltd amp our distributors will charge for your after service
14. works for 2min and for another one second the version will be displayed TEMPERATURE HUMIDITY on FND After version indication buzzer sounds for about 15sec Atthe same time present temp amp humidity displayed and power failure alarm indication is blinking TE RATURE HUMIDITY Press x button to remove buzzer and alarm indication Buzzer willbe removed automatically after 15sec x Notice of Power Failure If power is turned off and then on again because of power failure or by mistake first dot will blink gt np Quick Start If you just connect power it automatically starts incubation with factory setting Factory setting Temperature 37 5 C 99 5 F Humidity RH 45 gt Incubator display current temperature and humidity and it goes to setting conditions within an hour The artificial intelligence system memorizes and classifies ambient conditions for keeping optimum temperature and temperature can move up slowly at the first stage Egg Turning 3days before incubation please be sure to stop egg turning in tray and remove divider Be careful Chicks might be caught in turning cradle If the egg basket are located out of frames it cause problem for egg turning device gt How to align horizontally Press button for 3 seconds to align gt How to turn trays manually Press or button to adjust the tray turning manually while the incubator is working x
15. A 2 sees HUMIDITY gt Unplug power cord Replug during button is pressed e Then rSt AL will indicated in display and H amp B returns to factory setting Default setting TEMPERATURE d Calibrated temperature and humidity will also return to factory setting Temperature Setting Press and button at the same time then tEP will be indicated for about 0 5sec and then temp display will blink Then you can adjust temperature with and button HUMIDITY Default setting 37 5 99 5 F After setting required temperature press x button once 45 then setting will be stored Next rH will be indicated in humidity display for about 0 5sec and then humidity display will blink TEMPERATURE HUMIDITY x Just press button if you do not need to change setting Humidity Setting gt When humidity display is blinking adjust humidity setting with or button Default setting RH 45 TEMPERATURE gt If you keep pushing button under 19 humidity device is off and it shows as 2 After setting required humidity press button once then setting will be stored Next Hl abnormal high temp alarm will be indicated for about 0 5sec and then abnormal temp alarm setting value will blink N A C Y x Just press button if you do not need to change F setting TEMPERATURE HiMD TEMPERATURE HUMIDITY Tip Temperature an
16. Default 1hr D di control range Ihr 3hrs Press button after setting value to save what you change and then the newly set value is blinking after Trn2 set turning cycle for right side cladle is displayed for 0 5 second to go to next stage x Press button to skip this stage Press or button to increase or to decrease value in the set mode of turning cycle blinking of set value Default 1 hr gt ip control range Ihr 3hrs Press button after setting value to save what you change and then the newly set values of temperature and humidity are displayed Be sure to stop egg turning 3 days before hatching Refer to the Page 12 DIGITAL INCUBATOR button to increase or to decrease Interval Setting HUMIDITY TEMPERATURE HUMIDITY Repeat Once Lamp ON Twice Lamp ON 3Times Lamp ON Egg turning Interval 2hours Egg turning Interval 3 hours Egg turning Interval an hour HUMIDITY TEMPERATURE HUMIDITY Repeat Once Lamp ON Twice Lamp ON 3Times Lamp ON Egg turning Interval 2 hours Egg turning Interval 3hours Egg turning Interval an hour HUMIDITY HUMIDITY so mmm mm mu TEMPERATURE TEMPERATURE 1 Disassembling and 9 How to Clean Cleaning the Incubator Disassembling and Cleaning the Incubator A Be sure to remove power before cleaning gt If you turn off incubator and then let the incubat
17. Manual 6 Broken or problem caused by Customer s mistake or fault x Product Registration Procedures If you are a new member of Rcom you need to log in our website at www Rcom co kr 1 Click SIGN UP on top of the right corner 2 Fill out the information on the blanks If you already registered your information on the Rcom website please log in to www Rcom co kr 1 Click Login on top of the right corner 2 Select Customer and click Register Products 3 Fill out the information on the blanks You will need below information to register on our website 1 Your name 2 Your home company address amp Email address country 3 Your product model name amp Serial number 4 Date of purchase 8 Name of purchased shop you bought from DIGITAL INCUBATOR Rcom Incubator Series incubator Rcom BROODER amp ICU Rcom DIGILOG Rcom DIGILOG2 MX BS500 N PX V1 PX V2 Rcom MARU 190 380 1000 PART LIST ELCNMELUNME m eee ES C38 811 10 C38 OP Pannel C38 611 10 Maru Water Tank C38 612 10 C38 OP Seal RCM 600 10 Suro Nipple C19 Humidity C38SMPS 110PCB 110 ASM C38 A300L 10 190 380 626 AC C38 A300H 10 C38SMPS 220PCB E 190 380 SIK OMES HIM C38 304 10 Power Inlet 6 PCB 1000 C1K SMPS 220 PCB 1000 EN C38 Main PCB C38 304 XX 10 Power Cord 6 Max ASM C38 Membrane ni C38 308 10 Micro SW C38 300 10 S
18. W MAX ds 190 380 rear C38 OP Frame 190 380 1 Membrane m C1K OP Frame SWMAX 1000 1000 C1K 300 10 C38 Upper Frame C38 Max 110 OP 190 380 8 A302ML ASM an C1K Upper Frame L 10 8 A302M H 10 Max 220 OP ASM 1000 C1K Max 110 OP ASM C38 008 10 C38 Shaft Arm C1K Max 220 om i OP ASM nn x C38 H754DB 10 Double Gear59T C38 A610 10 C38 Vent ASM RM C38 H754 10 Gear59T APS TH V2 RCM 301 10 E C38 H755 10 Gear20 RCM 705 10 Tube CLAMP C38 Synchro 110M otor 8 Synchro 220M otor RCM 706 10 Wire Hold RCM 700 10 Slicon Tube m C38 A 306 10 C38 Water uud Motor ASM RCM 707 10 E Ring5 C38 303 10 C38 Thermostat RCM 708 10 E Ring6 x Partly spare parts are not on the parts list Rcom MARU 190 380 1000 PART LIST ome ESA C38 009 10 C38 013 10 C1K 018 10 C19 005 10 C38 014 10 C38 307 10 Names of goods Compatible C38 Turning 110 Motor ASM C38 Turning 220 Motor ASM C38 Egg Tray Support C38 Link Bar 190 380 C1K Link Bar 1000 C19 Cradle Tray 190 C38 Cradle Tray 380 1000 BLDC FAN80 C19 Heat 300WL ASM C19 Heat 300WH ASM C38 Heater 300WL ASM C38 Heater 300WH ASM C38 042 10 C38 043 10 C38 024 10 x Partly spare parts are not on the parts list C1K Heater 300WL ASM C1K Heater 300WH ASM C19 Top Body 110 ASM C19 Top Body 220 ASM C38
19. and sometimes need higher than that However in areas of high ambient humidity lower levels of humidity may be needed during incubation Air Controlling Lever Outer fresh air can be flowed into incubator inside without affecting insulation When eggs start hatching open air controlling lever either fully or half open gt It is normal that wa ter might leak in case of high humidity gt If the temperature where incubator installed is high it will effects to incubator setting temperature In this case you are able to adjust temperature by Air ventilation on the top of machine You can adjust Air Ventilation 1 4 open 1 2 open close wide open A If you set high temperature condensation will occur and may causes licking water from the incubator and it is not a technical problem You need to keep temperature between 28 C 82 4 P Especially during at night temperature drops dramatically from time to time in winter season so maintain inner and outer temperature is important to prevent condensation Maintenance after Hatching gt It is necessary to use a brooder for baby chicken or bird since they are too week against cold or cool environment If you try egg hatching in your incubator there would be lots of germs feathers which causes of low egg hatching possibility for your next hatching Also they can make your incubator broken or faulty We strongly recommend you to use independent Hatcher or Brooder for egg hatching
20. andling for your machine In this case Autoelex Co Ltd amp our distributors will charge for your after service place eggs adjusting dividers in terms of the egg size A Be sure to fit eggs to space made by two dividers It is recommended to place eggs with sharp end side down gt Perform the horizontal alignment by pressing button for 3 seconds In case the horizontal alignment is not completed successfully you can adjust manually by pressing button Do not open the door while the alignment is working Before placing an egg basket in the incubator be sure to power off the incubator or to turn off the egg turning Before placing eggs in the incubator it is recommended to turn on and stabilize the temperature of incubator for a few hours Be sure to close the door completely if not the temperature and humidity will fail to go up please check if the machine s floor is wet or not otherwise you may not reach the normal temperature d The egg to incubate must be a fertilized egg A Please make it balanced when puting eggs on the egg basket 10 DIGITAL INCUBATOR 3 ncu bat f on 1 Preparation for Incubation How to Start Incubation 2 Egg Turning Humidification How to Terminate Incubation How to start incubation For the first two seconds after power on FND blinks and the pump starts working until water is filled 2 d In case of water shortage it
21. ater container on the bottom Place incubator under a level surface A Be sure that the incubator works without any problem before placing eggs in the incubator DIGITAL INCUBATOR 2 Troubleshooting 6 Product Information 3 Specification S ificati 1 1 Name Rcom MARU 190 380 1000 Cradle Type pecitication 1 2 Model MAX CT Series CT Series grise Egg Turning Egg turning E ii p Functional M Method egg size min floors Rcom MARU rows temperature 20 42 C 68 107 6 F Rcom MARU BR rows temperature 20 42 C 68 107 6 F 1rows egg Turnin Rcom MARU ee ON OFF temperature 20 42 68 107 6 F idificati blica ES Humidification electric power electric power Device W W 70 Rcom MARU Egg basket A79 Rcom MARU Egg basket Rcom MARU Egg basket 790 MX 1000C 845 790 890 53 440 70 A We are not allowed to extend warranty therefore we ONLY provide 1 year warranty service YA You will be asking for service charge if you are in below cases 1 Broken or Problem caused by No cleaning or Improper handling 2 Broken or problem caused by Not using distilled water 3 Broken or problem caused by Trying Bird hatching in incubator Please don t try bird hatching in incubator Please use Hatcher during bird hatching 4 Broken or problem caused by Wrong controling Using 5 Broken or Problem caused by using the machine out of User s
22. casionally fur dirt or water disturb the accurate measurement of temperature amp humidity Please clean up furs or dirts with soft brush Please make them assembled by the reverse procedure Cleaning of Incubator Inside After hatching remove egg basket and divider inside of incubator and clean the inside with vacuum cleaner Tiny dust should be removed with brush again d After several hatching dust or bird feathers can stick to the incubator inside which maybe cause malfunction So you should to clean the incubator carefully after every time of hatching The life span of the evaporating heater can be reduced when used without cleaning A When the condition of dirty substance cleaning it can create fan noise or further fan stop Clean the egg basket and dividers with water and an antiseptic solution and then dry naturally or operate incubator temporary to dry them A Be careful not the moisture gets into the power connecting part on the backside of incubator A Do not clean the incubator with benzene or thinner Risk of transformation or decolorization DIGITAL INCUBATOR 1 How to Replace Fuse Servicing 6 Product Information Frequently Asked Questions FAQ How to Replace Fuse Replace A Used Fuse fuse with B Spare Fuse fuse For AC 100V use 250V 5 0A O5 20mm For AC 230V use 250V 3 0A O5 20mm gt Fuse is located at the top of power connection part on back side of incubator
23. d humidity is optimized when Rcom products are released We do no recommend customers to recalibrate by their own If you need to recalibrate please visit our website www rcom co kr Download Manual or ask purchase place Because of low price thermometers and hygrometers are not accurate e recommend you to use special calibrated thermo hydrometer Poultry only thermo hydrometer check Rcom website Digilog 14 DIGITAL INCUBATOR 4 Function Settin gs 3 How to preserve the humidification unit part How to Set Abnormal High amp Low Temp Alarm How to preserve the humidification unit part To maintain the temperature to be level as normal in humidification unit the manual type thermostat is applied to the area shown in picture just push the knob shown in picture unless the water get to be heated in spite of staring the humidification function gt When the humidity unit is not working even if you keep pressing the thermostat knob to downward or it keeps turned off automatically please contact our customer service A warning when you touch the thermostat swithch please make sure the power cord is plugged out Manual thermostat ay Press ON How to Set Abnormal High Temperature Alarm gt Adjust abnormal high temperature value with or button Default setting 2 C mm C 45 sss TEMPERATURE HUMIDITY gt After setting required value press x button to save Then it will go to the
24. e 621 843 KOREA O TEL 82 55 337 2560 Direct to sales team 82 55 337 2561 3 Office O FAX 82 05 331 2568 O E MAIL Rcom Rcom co kr Rcom is the Best Design with High Quality Value and Performancel
25. e machine and manage the incubator are also important Certainly we provide optimal hatching environment but need to be managed temperature and humidity carefully depends on egg species environment and capacity moreover Rcom MARU has been designed already to provide the best optimal hatching environment therefore before using the incubator we strongly recommend you that please read the manual carefully Main Function MAX 190 380 1000 Intergarted simplify control pannel superior maintenance Automatic temperature amp humidity control and set function Automatic egg turning amp turning interval set function 1h 2h 3h FND display for easy recognition of incubation state Artificial intelligence electronic control system applied from Rcom utmost technology High reliability temperature and humidity sensor applied produced by Sensirion Swiss ver 3rd Generation of sensirion Swiss Transparent double insulated view window Sliding Air vent able to control the air in the chamber Minimized temperature variation applied from Rcom optimum air flow technology Water heating system for evaporation eliminating bacteria Water level sensing amp warning system Superb high density foam board for maintaining stable temperature amp maximizing energy efficiency The safety device of the humidification unit is attached on the Thermostat Useful Function MAX 190 380 1000 Degree C degree F interchan
26. er the direct Do not install in moist or Do not install in excessively not use any other environment sunlight humid environment cold or hot conditions non standard parts except gt Risk of damage or fire within Risk of fire or interference Risk of fire or electric shock cigarette smoke etc those provided the incubator with the incubation process Risk of interference with Risk of damage or hatching the incubation process failure Do not cover the ventilating Install away from heat Ensure that the incubator is If the incubator requires repair Children should be supervised opening Sources installed on a stable surface disconnect from the power to ensure that they do not play gt Inner temperature can rise Risk of damage to the away from edges supply and please contactto with the appliance interrupting incubation incubator case and Risk of damage to incubator your service center Risk of knocking the incubator interference with the and eggs and user from or accidental interference with incubation process accidental knocks or drops the controls Do disassemble or modify Please ensure that no small If the incubator sounds Clean the incubator Do not place water container the incubator in any way objects get into strange or emits smoke thoroughly before storing on the incubator gt Risk if electric shock or fire the holes on the incubator contact your service center gt Risk of electric shock or fi
27. geable Hatching chamber equipped Egg turning stop on opening window Inbuilt humidifying system Warning amp display function of abnormal temperature caused by ambient temperature fluctuation Incubation data memory and alarm function in case of blackout Equipped Water nipple in front for handy water supply Auto horizontal egg turner stop function amp manual egg turner positioning function Each egg turner operation available selectively Model No MX 1000C Adjustable universal egg tray able to placing different eggs according to the species sold separately Top cover can be opened for easy cleaning and maintenance after hatching OPTION MAX 190 380 1000 Universal egg basket ABS Divider a4 DIGITAL INCUBATOR MARU 1 Introduction 2 Safety Precautions Electrical hazards ACAUTION Be careful the details below when you use Do not use a damaged power Do not pull the cord when Never pull the plug out of the Do not twist or crush electric Do not insert multiple cord or loose outlet taking out the power cord and outlet during the incubation cord connecting plugs in an outlet gt Risk of electric shock or fire keep wet hands away from period gt Risk of electric shock or fire Risk of fire or electrical connecting plug gt Incubation will be interrupted overload Cautions mE Be careful the details below when you use Do not install in dusty or dirty Do not install und
28. me with abnormal high temp Zu EN PS alarm function NY How to change Centigrade amp Fahrenheit Select C or F with or button gt 3 in gt After selecting or F press button to save F 76 Default setting C TEMPERATURE HUMIDITY Press button after choosing Centigrade or CS 9 Fahrenheit to save what you change and then set value is blinking after Trn set turning cycle is displayed for A 0 5 second on temp FND for 190 380 to go to next stage For MAX 1000 set value is blinking after Trn1 set turning cycle for left side cradle is displayed for 0 5 second Ds di How to change Centigrade value to Fahrenheit C 5 9 F 32 Just press button if you do not need to change setting 16 DIGITAL INCUBATOR MARU 4 Function Settings 5 Egg Turning Egg Turning Interval Setting Rcom MARU MAX 190 MAX 380 Press or value in the set mode of turning cycle blinking of set value Default 1 hr a Un control range Ihr 3hrs Press button after setting value to save what you change and then the newly set values of temperature and humidity are displayed A Be sure to stop egg turning 3 days before hatching Refer to the Page 12 Rcom MARU MAX 1000 Press or to increase 1hr or to decrease Ihr in the set mode of turning cycle blinking of set value
29. on fan Egg Turning fails to work Dew foams in the incubator Water leaks from the machine gt Check electric cord is properly connected gt Check if there is a power outage gt Check whether the plug is damaged Check your setting temperature gt Initialize the incubator Refer to the page 14 gt please check the bottom of machine is wet or not gt Check if room temperature is too high gt Check if incubator is exposed to the direct rays of sun gt In case of lowering temperature gt Check water for humidity Check if room temperature is too low Check if incubator heater temperature controlling system is normally working gt please check the bottom of machine is wet or not Check your setting humidity Close the door again after checking Initialize the incubator Refer to the page 14 Check if pumping is working Refer to the page 12 You need to confirm that if the thermostat S W knob is side up in the humidity unit section gt Check if there is any hatching debris such as feather or eggs shell in the incubator FAN gt A little noisy is not faulty Check that the Egg turning stoppage is not activated Egg turning lamp lighting gt Check that there are no foreign items on the egg turning tray Check if egg turning plate is assembled correctly Please confirm if any divider are not stuck in the middle of machine gt Check the incubator
30. or with door closed after high humidity incubation moisture inside of the incubator evaporates and sticks to electric device This could cause problem and be sure to open door of incubator and completely remove moisture inside of incubator Cleaning of Control Part gt Loosen screws on the top of the incubator as the below pictures and lift up the cover to open gt Remove water inside of incubator Open the maintenance cover and remove all dust and foreign thing on the humidification unit and the fan with brush After cleaning reassemble the maintenance cover again Please clean up the humidification unit and the fans after egg hatching Rcom MARU 190 380 1000 When scratched or hit by something humidification heater be damaged when open the top cover be sure to pull electric cord out and get rid of water dirt Please be sure to remove the harden dirty substance on the heater surface when cleaning after hatch 18 DIGITAL INCUBATOR 1 Disassembling and to Clean Cleaning the Incubator gt Thermostat S W knob when over heated in humidification area automatically functioned OFF However humidification area goes back to normal function when pressed down after getting rid of the cause of abnormal high temperature Please make sure to notnly ON signal show the humidity heater in operation gt Temperature and humidity sensor lie in upper part inside incubator oc
31. re Risk of electric shock or fire Cleaning Cautions A CAUTION Be sure to disconnect the electric cord from the outlet before cleaning Clean the incubator by a soft Brush away dust on the plug Do not use chemicals like wax For special cleaning of inner cloth with a neutral detergent with a dry cloth benzene alcohol thinner part per year contact to the aromatic or lubricant etc service center If you don t clean the inside of incubator for a long time dust can cause some trouble or a fire DIGITAL INCUBATOR 3 Identification of Parts 1 Introduction 4 Basic Components Identification of Parts MX 380C model image Digital Control Center Power Connecting the rear See description of For connecting the function and operation Air vent Top power cord Temperature Air inlet vent humidity sensor For inlet of air i from outside gt Air vent Front Nipple for water hose Insulation Board or Pannel Door For a clear view of the incubation process Duplicated Viewing Window Egg Tray Cradle 190 380 3 stage one column 1000 4 stage double columns Please do not use regular water mineral water or tap water We strongly sold separately recommend to use Hatchery room Distilled Water Temporary space for to protect the hatchery humidifying unit Basic Components Easy function Silicon Tube 1 5m opera
32. tion Preparation for Incubation When the power cord is plugged into power after the power cord is connected to power connecting in the rear the digits on the temperature and humidity FND appear and temperature and humidity is moderately getting increased Even though you can smell bad it is normal A Do not connect power supply before the incubator is assembled completely Risk of electric shock Please check and refill water every 2 days during incubation If the water tank is small please check everyday A In case you use the incubator without adding humidification water or intend to incubate eggs at low humidity under RH 20 you must stop its humidification function please turn off the humidity unit if the unit is empty water otherwise humidity unit will be broke or you may not no longer use the unit When using this function the alarm for sensing water drop will go out See the description of humidification function OFF on Page 12 x How to turn off Humidification Function Set humidity under RH 20 A If you use Mineral water or Tap water for humidification the humidity unit can be broken easily because of water scales We strongly recommend you to use only DISTILLED WATER for your machine and Autoelex Co Ltd amp our distributors do not indemnify for warranty service not only if you have any problem with using mineral water regular water tab water and the like but also if you had improper management or h
33. tion diameter 24 6 Can be attached Power Cord anywhere for Manual easy viewing Sold Separately AA Bm Piece 28 EA SLOT 2EA 2 16 e a ABS Divider Rotary wheel Bracket MARU 190 Series 5EA 4EA MARU 190 Series 30EA MARU 190 Series 4EA MARU 380 Series 10EA 8EA MARU 380 Series 60EA MARU 380 Series 4EA MARU 1000 Series 24EA 16EA MARU 1000 Series 160EA MARU 1000 Series 4EA DIGITAL INCUBATOR 5 Name amp Function of 1 Introduction Operation Parts Name amp Function of Operation Parts Rcom MARU MAX 190 380 Humidity Water Empty Rcom MARU MAX 1000 Rcom MARU max Sg 55 F Temperature Humidity TurningOn L R Water Empty DIGITAL INCUBATOR 15 1 Heater Operation Lamp Light on when working Egg Turning Button Egg turning plate level Setting egg turning ON OFF e DISplay 9 Pumping Button Starting pumping motor for humidity 3 Humidity Display Current Humidity Display Safety Function Button With other buttons together 4 Pumping System Operation Lamp Light on when Setting value check working 1 Power Failure Alarm Function Blink with power failure 5 Up Button Setting Temp amp Humidity UP to remove press SET button Calibrated Temp amp humidity UP 2 Egg Turning Lamp Turn on with automatic egg turning mode Manual egg turning button Blink when working 6 Down Button Setting Temp amp Humidity DOWN
34. urning sound 4 trn1 L MAX 1000 n Default 1hour trn2 R gt or Egg Turning Default 1hour put some water after take off label from the back and attach MAX 190 380 1000 Egg Turning MAX 1000 ONLY MAX 190 380 1000 MAX 190 380 ONLY MAX 1000 ONLY MAX 190 380 1000 DIGITAL INCUBATOR T 1 What is incubation room ARU 2 Before Use 2 How to Install Incubator What is an Incubation Room The Incubation Room is a confined space for setting and operating an incubator Because the incubation room environment has a considerable effect on hatch rate it s recommended to control the environment for setting up an incubator there should be little noise and vibration around and temperature ranging 28 C 82 4 F with small variation in temperature Especially if there are frequent occasions when the temperature drops suddenly at night compared with daytime be sure to check from time to time and pay attention so that the incubator is not directly exposed to sunlight during daytime A If you set high temperature condensation will occur and may causes licking water from the incubator and it is not a technical problem You need to keep temperature between 28 82 4 F How to Install Incubator gt Please set the incubator flatways on the strong and 50 cm or above tallish table gt In case of the level surface is indentation it might occur a

Download Pdf Manuals