1. Item Description e Powersupply 20 52 SSCS sence Video connector o lO comer 10 Serial connector FlexLOM ports Shown 4x1Gb Optional 2x10Gb port 1 on right side Rear panel LEDs and buttons Component identification 12 mpe Baw O UID LED button Off Deactivated Solid blue Activated Flashing blue System being managed remotely 2 Power supply 2 Off System is off or power supply has failed LED Solid green Normal Power supply 1 Off System is off or power supply has failed LED Solid green Normal NIC activity LED Off No network activity Solid green Link to network Flashing green Network activity 5 NIC link LED Off No network link Green Network link Non hot plug PCI riser board slot definitions e Primary riser cage connector connected to processor 1 or the southbridge P PCle 3 slot riser cage PCle 2 slot x16 riser cage 1 FL FH eee eee eS 2 HL FH PCle2 or PCle3 x8 8 4 2 1 PCle2 x8 4 2 1 t el e Secondary riser cage connector connected to processor 2 Processor 2 must be installed PF PCle 3 slot riser cage PCle 2 slot x16 riser cage 4 FL FH PCle2 or PCle3 x16 16 8 4 2 1 PCle2 or PCle3 x16 16 8 4 2 1 5 HL FH PCle2 or PCle3 x8 8 4 2 1 PCle2 or PCle3 x16 16 8 4 2 1 6 HL FH PCle2 or PCle3 x8 8 4 2 1 The server ships with one PCle3 riser cage installed in the primary riser cage connector These slo
2. 1 Size 1R Single rank 2R Dual rank AR Quad rank x4 Abit x8 8 bit Voltage rating L Low voltage 1 35v U Ultra low voltage 1 25v Blank or omitted Standard Memory speed 12800 1600 MT s 10600 1333 MT s 8500 1066 MT s DIMM type R RDIMM registered E UDIMM unbuffered with ECC L LRDIMM load reduced Hardware options installation 49 For the latest supported memory information see the QuickSpecs on the HP website http 7h18000 www1 hp com products quickspecs ProductBulletin html At the website choose the geographic region and then locate the product by name or product category Memory configurations To optimize server availability the server supports the following AMP modes e Advanced ECC provides up to 4 bit error correction and enhanced performance over Lockstep mode This mode is the default option for this server e Online spare memory provides protection against failing or degraded DIMMs Certain memory is reserved as spare and automatic failover to spare memory occurs when the system detects a DIMM that is degrading This allows DIMMs that have a higher probability of receiving an uncorrectable memory error which would result in system downtime to be removed from operation Advanced Memory Protection options are configured in RBSU If the requested AMP mode is not supported by the installed DIMM configuration the server boots in Advanced ECC mode For more information
3. Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 Connect each power cord to the server Connect each power cord to the power source Power up the server on page 21 Installing the flash backed write cache capacitor pack Z CAUTION The cache module connector does not use the industry standard DDR3 mini DIMM pinout Do not use this controller with cache modules designed for other controller models because the controller can malfunction and you can lose data Also do not transfer this cache module to an unsupported controller model because you can lose data To install the component 1 2 Back up all data Close all applications Z CAUTION In systems that use external data storage be sure that the server is the first unit to be powered down and the last to be powered back up Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up Power down the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Install the FBWC module Installing the flash backed write cache module on page 56 if it is not already installed Hardware options installation 57 8 Connect the capacitor pack cable to the conn
4. For more information on RBSU see the HP ROM Based Setup Utility User Guide on the Documentation CD or the HP website http www hp com support rbsu Using RBSU To use RBSU use the following keys e To access RBSU press the F9 key during power up when prompted e To navigate the menu system use the arrow keys e To make selections press the Enter key e To access Help for a highlighted configuration option press the F1 key We IMPORTANT RBSU automatically saves settings when you press the Enter key The utility does not prompt you for confirmation of settings before you exit the utility To change a selected setting you must select a different setting and press the Enter key Default configuration settings are applied to the server at one of the following times e Upon the first system power up e After defaults have been restored Default configuration settings are sufficient for proper typical server operation but configuration settings can be modified using RBSU The system will prompt you for access to RBSU with each power up Auto contiguration process The auto configuration process automatically runs when you boot the server for the first time During the power up sequence the system ROM automatically configures the entire system without needing any intervention During this process the ORCA utility in most cases automatically configures the array to a default setting based on the number of drives connected to the serv
5. 20 Install the server into the rack Installing the server into the rack on page 36 21 Connect each power cord to the server 22 Connect each power cord to the power source 23 Power up the server on page 21 Hardware options installation 46 Memory options We IMPORTANT This server does not support mixing LRDIMMs RDIMMs or UDIMMs Attempting to mix any combination of these DIMMs can cause the server to halt during BIOS initialization The memory subsystem in this server can support LRDIMMs RDIMMs or UDIMMs e UDIMMSs represent the most basic type of memory module and offer lower latency in one DIMM per channel configurations and relatively low power consumption but are limited in capacity e RDIMMs offer larger capacities than UDIMMs and include address parity protection e LRDIMMs support higher densities than single and dual rank RDIMMs and higher speeds than quad rank RDIMMs This support enables you to install more high capacity DIMMs resulting in higher system capacities and higher bandwidth All types are referred to as DIMMs when the information applies to all types When specified as LRDIMM RDIMM or UDIMM the information applies to that type only All memory installed in the server must be the same type The server supports the following DIMM speeds e Single and dual rank PC3 10600 DDR 1333 RDIMMs operating at up to 1333 MT s e Single and dual rank PC3 12800 DDR 1600 RDIMMs operating
6. Connect each power cord to the power source Power up the server on page 21 Remove the air baffle Z CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers or blanks installed If the server supports hot plug components minimize the amount of time the access panel is open To remove the component iF 2 Power down the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend or remove the server from the rack Extend the server from the rack on page 21 Remove the access panel on page 22 Z CAUTION Do not detach the cable that connects the battery pack to the cache module Detaching the cable causes any unsaved data in the cache module to be lost Wa IMPORTANT Itis necessary to remove the PCI riser cage only if there is a full length expansion board installed Operations 30 5 Release the full length expansion board retainer and then remove the PCI riser cage Ces To replace the component reverse the removal procedure Operations 31 Setup Optional installation services Delivered by experienced certified engineers HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems HP Care Packs let you integrate both hardware and software support into a single package A num
7. HP Operating Systems and Virtualization Software Support for ProLiant Servers cesceeseeeteeeteeeees 101 HP Technology Service POrtioliOiis a cxususiesssueesinunussnestnnctunchsuduauadadadssanseoastencbeisnsesuesiuaccussenbesnaiicbdcsaioel 101 Change control and proactive MerincOtialt ss c 20 ensicesunas eet eres een Eee 101 Wake as e a acne eens aoe ieteo E E E A 102 Troubleshooting resources ccssceeeseesseesseeeeseceseeeseecseecaeceseeceeceaeeeeeceaeceaeesseeeaeeeseeeeeenseseaeseneeenseeneeeeeens 102 Banery Fer rea a eae eee 103 Regulatory compliance TN ictal ans rene octucsni Soden a ddan een dionaraaaees 104 Regulatory compliance identification numbers 1 cc lt c h s cigcaanaies eae eu eee UREN EA GENES 104 Federal Communications Commission tictite 4 ee es 104 FCC rating ENE ic ieee uae ease ee eee 104 FCC Notice Class A Equipment c cccccccccsssceesscccssececsseceeseeeeseeecsseeessseeeeseesenseeessseeeesseeeneeeesseeenss 104 FCC Notice Class Bi Equipmentciscciccatcsteeidagetedeneciticaeeiagae E Gb Shad ak dee agen A 104 Declaration of conformity for products marked with the FCC logo United States only ccescceeseeeseeteetteeeees 105 Modifications sison E EE E ae eee 105 Cables me eee oe 105 Canadian notice Avis Canadien cccccccissssssctessssnctosessentcssssnctsessvactsessrernteossertcressescoresseuscnsesescnrecesseneee 105 European Union regulatory nvlce ae ee oe ee 106 Disposal of waste eq
8. The front panel Power On Standby button does not completely shut off system power Portions of the power supply and some internal circuitry remain active until AC power is removed 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Operations 28 5 Install the PCI riser cage 6 7 8 9 Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 Connect each power cord to the server Connect each power cord to the power source 10 Power up the server on page 21 Secure the full length expansion board retainer 1 2 oy amp p Power down the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Install a full length expansion board Installing a full length expansion board on page 66 Install the PCI riser cage on page 28 Operations 29 T Secure the full length expansion board retainer 10 11 12 Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 Connect each power cord to the server
9. and Blades within the data center HP SUM is used to deploy firmware and software in SPP HP SUM enables system administrators to upgrade ROM images efficiently across a wide range of servers and options This tool has the following features e Enables GUI and a command line scriptable interface e Provides scriptable command line deployment e Requires no agent for remote installations e Enables dependency checking which ensures appropriate install order and dependency checking between components e Deploys software and firmware on Windows and Linux operating systems e Performs local or remote one to many online deployment e Deploys firmware and software together e Supports offline and online deployment e Deploys necessary component updates only e Downloads the latest components from Web Software and configuration utilities 94 e Enables direct update of BMC firmware HP iLO For more information about HP SUM and to access the HP Smart Update Manager User Guide see the HP website http www hp com go hpsum documentation HP ROM Based Setup Utility RBSU is a configuration utility embedded in ProLiant servers that performs a wide range of configuration activities that can include the following e Configuring system devices and installed options e Enabling and disabling system features e Displaying system information e Selecting the primary boot controller e Configuring memory options e Language selection
10. system status and service alerts for various server components The Agentless Management Service is available in the SPP which is a disk image iso that you can download from the HP website http www hp com go spp download The Active Health System log can be downloaded manually from HP iLO or HP Intelligent Provisioning and sent to HP For more information see the HP iLO User Guide or HP Intelligent Provisioning User Guide on the HP website http www hp com go ilo docs Integrated Management Log The IML records hundreds of events and stores them in an easy to view form The IML timestamps each event with 1 minute granularity You can view recorded events in the IML in several ways including the following e From within HP SIM e From within operating system specitic IML viewers o For Windows IML Viewer o For Linux IML Viewer Application e From within the HP iLO user interface e From within HP Insight Diagnostics on page 93 Intelligent Provisioning Several packaging changes have taken place with HP ProLiant Gen8 servers SmartStart CDs and the Smart Update Firmware DVD will no longer ship with these new servers Instead the deployment capability is embedded in the server as part of HP iLO Management Engine s Intelligent Provisioning Intelligent Provisioning is an essential single server deployment tool embedded in HP ProLiant Gen8 servers that simplifies HP ProLiant server setup providing a reliable and consi
11. 42 installing the full length expansion board retainer 30 installing the server into the rack 39 installing the Trusted Platform Module board 83 Integrated Lights Out iLO 94 Integrated Management Log IML 95 Intelligent Provisioning 93 96 J Japanese notice 113 K Korean notices 113 L laser devices 114 LEDs 7 11 LEDs front panel 19 LEDs hard drive 19 LEDs SAS hard drive 19 LEDs troubleshooting 19 106 lockstep memory 53 54 M mechanical specifications 117 memory 49 50 51 53 memory configurations 52 53 memory dump 17 memory subsystem architecture 50 memory configuration requirements 52 54 memory configuring 52 53 memory lockstep 53 54 memory mirrored 101 memory online spare 53 100 mirrored memory 101 N NIC connectors 12 NMI jumper 17 O online spare memory 53 100 operating system crash 17 operating systems 105 optical drive 7 62 optical drive cable 87 optimum environment 35 Option ROM Configuration for Arrays ORCA 93 102 options installation 39 42 ORCA Option ROM Configuration for Arrays 93 102 P PCI expansion slots 14 23 PCI riser cage 29 30 70 phone numbers 122 power cord 115 power distribution unit PDU 36 Power On button 23 41 power requirements 36 power supply 64 power supply LEDs 13 power supply specifications 118 119 120 121 powering down 23 powering up 23 99 preparation procedures 23 problem diagnosis 106 R rack ins
12. An Internet connection is required to update the firmware and systems software e Remote deployment installation To remotely deploy an operating system use Insight Control server deployment for an automated solution For additional system software and firmware updates download the HP Service Pack for ProLiant from the HP website http www hp com go spp download Software and firmware must be updated before using the server for the first time unless any installed software or components require an older version For more information see Keeping the system current on page 100 The Smart Update Firmware DVD ISO is also available at the download tab on the HP website http www hp com go foundation For more information on using these installation methods see the HP website http www hp com go ilo Powering on and selecting boot options 1 Connect the Ethernet cable and press the Power On Standby button 2 During the initial boot Setup 38 o To modify the server configuration ROM default settings press F9 when prompted from the start up sequence to enter the RBSU By default RBSU runs in the English language If you do not need to modify the server configuration and are ready to install the system software press F10 to access Intelligent Provisioning NOTE If an HP Smart Array controller has been added or is embedded in the system the controller defaults to a RAID configuration based on the size and number of hard
13. FUO HSE SH FI Hgo APSE AACS YY EE ANZ SO HSE YSUch Z0 HQHH HP I AS MAS ASIA S AS Sxl Ae SSS SAUCE HPE ABO WS HSS HPS BSO SHEA OFS CSR WA FER Sa SE ABO AVA BHH Z sto wet FES HPS HEO SHE APOE ABE 712 SA BAS F 5U HPS BEHO Sch O tf ABO WAS FSS MAE EA ARO Vol Bei AAA B EHO ELCH AEO Wy st PES WHS YE BP HP DA HHO Hal SS APS USC WA MB eel BS HPE BESSY HE vist use rH ose SSeia W Huh Mul AS Ag euch HP 24 Az a z240 CHS AASELISS TES MMA HZY SASHA S0 z2 za HHE HP A AtO E hitp www hp com go selfrepai amp E HESIA S Technical support 122 Acronyms and abbreviations ABEND abnormal end ACU Array Configuration Utility AMP Advanced Memory Protection ASR Automatic Server Recovery CSA Canadian Standards Association CSR Customer Self Repair DDDC Double Device Data Correction DDR double data rate FBWC flash backed write cache IEC International Electrotechnical Commission iLO Integrated Lights Out IML Integrated Management Log Acronyms and abbreviations 123 ISEE Instant Support Enterprise Edition LFF large form factor NMI non maskable interrupt NVRAM non volatile memory ORCA Option ROM Configuration for Arrays PCle peripheral component interconnect express POST Power On Self Test PSP ProLiant Support Pack RBSU ROM Based Setup Utility RDIMM Registered Dual In line Memory Module RDP Rapid Deployment Pack SAS serial attach
14. OS before the server enters standby mode e Press and hold the Power On Standby button for more than 4 seconds to force the server to enter standby mode This method forces the server to enter standby mode without properly exiting applications and the OS If an application stops responding you can use this method to force a shutdown e Usea virtual power button selection through HP iLO This method initiates a controlled remote shutdown of applications and the OS before the server enters standby mode Before proceeding verify the server is in standby mode by observing that the system power LED is amber Extend the server from the rack 1 Pull down the quick release levers on each side of the server 2 Extend the server from the rack A WARNING To reduce the risk of personal injury or equipment damage be sure that the rack is adequately stabilized before extending a component from the rack Operations 21 3 After performing the installation or maintenance procedure slide the server back into the rack and then press the server firmly into the rack to secure it in place Z WARNING To reduce the risk of personal injury be careful when pressing the server rail release latches and sliding the server into the rack The sliding rails could pinch your fingers Remove the access panel Z WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to c
15. Teil von einem HP Servicepartner ersetzt werden Im illustrierten Teilekatalog sind diese Teile mit No bzw Nein gekennzeichnet Technical support 117 CSR Teile werden abh ngig von der Verf gbarkeit und vom Lieferziel am folgenden Geschaftstag geliefert Fir bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verf gbar Wenn Sie Hilfe ben tigen k nnen Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen Den Materialien die mit einem CSR Ersatzteil geliefert werden k nnen Sie entnehmen ob das defekte Teil an HP zuriickgeschickt werden muss Wenn es erforderlich ist das defekte Teil an HP zuriickzuschicken m ssen Sie dies innerhalb eines vorgegebenen Zeitraums tun in der Regel innerhalb von f nf 5 Geschaftstagen Das defekte Teil muss mit der zugeh rigen Dokumentation in der Verpackung zuriickgeschickt werden die im Lieferumfang enthalten ist Wenn Sie das defekte Teil nicht zur ckschicken kann HP Ihnen das Ersatzteil in Rechnung stellen Im Falle von Customer Self Repair kommt HP fir alle Kosten f r die Lieferung und R cksendung auf und bestimmt den Kurier Frachtdienst Weitere Informationen ber das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort Informationen ber das CSR Programm in Nordamerika finden Sie auf der HP Website unter http www hp com go selfrepair Reparaciones
16. bit failures can be corrected without resulting in system downtime Online Spare Mode Provides protection against failing or degraded DIMMs Certain memory is set aside as spare and automatic failover to spare memory occurs when the system detects a degraded DIMM DIMMs that are likely to receive a fatal or uncorrectable memory error are removed from operation automatically resulting in less system downtime For DIMM population requirements see the server specific user guide Re entering the server serial number and product ID After you replace the system board you must re enter the server serial number and the product ID 1 2 3 4 During the server startup sequence press the F9 key to access RBSU Select the Advanced Options menu Select Service Options Select Serial Number The following warnings appear Software and configuration utilities 96 10 11 WARNING WARNING WARNING The serial number is loaded into the system during the manufacturing process and should NOT be modified This option should only be used by qualified service personnel This value should always match the serial number sticker located on the chassis Warning The serial number should ONLY be modified by qualified service personnel This value should always match the serial number located on the chassis Press the Enter key to clear the warning Enter the serial number and press the Enter key Select Product ID The following warning
17. de eerstvolgende werkdag Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden indien dit mogelijk is gezien de locatie Indien assistentie gewenst is belt u een HP Service Partner om via de telefoon technische ondersteuning te ontvangen HP vermeldt in de documentatie bij het vervangende CSR onderdeel of het defecte onderdeel aan HP moet worden geretourneerd Als het defecte onderdeel aan HP moet worden teruggezonden moet u het defecte onderdeel binnen een bepaalde periode gewoonlijk vijf 5 werkdagen retourneren aan HP Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal Als u het defecte onderdeel niet terugzendt kan HP u voor het vervangende onderdeel kosten in rekening brengen Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier transportonderneming hiervoor wordt gebruikt Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP Informatie over Service Partners vindt u op de HP website hitp www hp com go selfrepair Reparo feito pelo cliente Os produtos da HP s o projetados com muitas pe as para reparo feito pelo cliente CSR de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substitui o de pe as com defeito Se durante o per odo de diagn stico a HP ou fornecedores parc
18. deve sostenere le spese di spedizione e di manodopera per il servizio Opzionali Parti la cui riparazione da parte del cliente facoltativa Si tratta comunque di componenti progettati per questo scopo Se tuttavia il cliente ne richiede la sostituzione ad HP potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto NOTA alcuni componenti HP non sono progettati per la riparazione da parte del cliente Per rispettare la garanzia HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato Tali parti sono identificate da un No nel Catalogo illustrato dei componenti In base alla disponibilit e alla localit geografica le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente La consegna nel giorno stesso o entro quattro ore offerta con un supplemento di costo solo in alcune zone In caso di necessit si pu richiedere l assistenza telefonica di un addetto del centro di supporto tecnico HP Nel materiale fornito con una parte di ricambio CSR HP specifica se il cliente deve restituire dei componenti Qualora sia richiesta la resa ad HP del componente difettoso lo si deve spedire ad HP entro un determinato periodo di tempo generalmente cinque 5 giorni lavorativi Il componente difettoso deve essere restituito con la documentazione associata nell imballo di spedizione fornito La mancata restituzione del componente pu comportare la fatturazione del
19. drives installed For more information on modifying the controller default settings see the documentation on the Documentation CD For more information on automatic configuration see the HP ROM Based Setup Utility User Guide on the Documentation CD or the iLO Management Engine Information Library http www hp com go ilomgmtengine docs Registering the server To register the server refer to the HP Registration website http register hp com Setup 39 Hardware options installation Introduction If more than one option is being installed read the installation instructions for all the hardware options and identify similar steps to streamline the installation process Z WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them Z CAUTION To prevent damage to electrical components properly ground the server before beginning any installation procedure Improper grounding can cause electrostatic discharge Processor and fan option The server supports single and dual processor operation Z CAUTION To avoid damage to the processor and system board only authorized personnel should attempt to replace or install the processor in this server Z CAUTION To prevent possible server malfunction and damage to the equipment multiprocessor configurations must contain processors with the same part number We IMPORTANT If installing
20. failed and data has been lost Flashing 1 Hz Flashing 1 Hz A power error occurred during the previous or current boot Data may be corrupt Flashing 1 Hz On OH Anovertemperature condition exists Flashing 2 Hz Flashing 2 Hz The capacitor pack is not attached Flashing 2 Hz Flashing 2 Hz The capacitor has been charging for 10 minutes but has not reached sufficient charge to perform a full backup Off The current backup is complete but power fluctuations occurred during the backup Hot plug fans Component identification 19 Z CAUTION To avoid damage to server components fan blanks must be installed in fan bays 1 and 2 in a single processor configuration The only two valid fan configurations are listed in the following table Fan bay 1 Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6 Fan Fan Fan Fan Fan Fan 2 processors For a single processor configuration four fans and two blanks are required in specific fan bays for redundancy A fan failure or missing fan causes a loss of redundancy A second fan failure or missing fan causes an orderly shutdown of the server Installing more than the required number of fans in a single processor configuration is not a supported configuration For a dual processor configuration six fans are required for redundancy A fan failure or missing fan causes a loss of redundancy A second fan failure or missing fan causes an orderly shutdown of
21. input power 815 W at 36 VDC input 805 W at 48 VDC input 795 W at 72 VDC input Btus per hour 2780 at 36 VDC input 2740 at 48 VDC input 2720 at 72 VDC input 750 W Specifications 113 HP 1200 W CS HE Power Supply 90 specifications Specification Input requirements Rated input voltage Rated input frequenc Rated input current Maximum rated input power Btus per hour Power supply output Rated steady state power Maximum peak power Value 100 to 120 VAC 200 to 240 VAC 50 Hz to 60 Hz 9 1 Aat 100 VAC 6 7 A at 200 VAC 897 W at 100V AC input 1321 W at 200V AC input 3408 at 120V AC input 4433 at 200V to 240V AC input 800 W at 100V AC input 900 W at 120V AC input 1200 W at 200V to 240V AC input 800 W at 100V AC input 900 W at 120V AC input 1200 W at 200V to 240V AC input Specifications 114 Technical support Before you contact HP Be sure to have the following information available before you call HP Technical support registration number if applicable Product serial number Product model name and number Product identification number Applicable error messages Add on boards or hardware Third party hardware or software Operating system type and revision level HP contact information For United States and worldwide contact information see the Contact HP website http www hp com go assistance In the United States To contact HP by phone call 1 800 334 5144 For
22. point to a repository managed by VCRM For more information about version control tools see the HP Systems Insight Manager User Guide the HP Version Control Agent User Guide and the HP Version Control Repository User Guide on the HP website http www hp com go hpsim Software and configuration utilities 100 HP Operating Systems and Virtualization Software Support for ProLiant Servers For information about specific versions of a supported operating system see the HP website http www hp com go ossupport HP Technology Service Portfolio HP Technology Services offers a targeted set of consultancy deployment and service solutions designed to meet the support needs of the most business and IT environments Foundation Care services deliver scalable hardware and software support packages for HP ProLiant server and industry standard software You can choose the type and level of service that is most suitable for your business needs HP Collaborative Support With a single call HP addresses initial hardware and software support needs and helps to quickly identify if a problem is related to hardware or software If the problem is identified as hardware HP will resolve as per service level commitments If the reported incident is related to HP or supported 3rd party software product and cannot be resolved by applying known fixes HP will contact the third party vendor and create a problem incident on the your behalf HP Proactive C
23. ricambio da parte di HP Nel caso di riparazione da parte del cliente HP sostiene tutte le spese di spedizione e resa e sceglie il corriere vettore da utilizzare Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona Per il programma in Nord America fare riferimento al sito Web HP http www hp com go selfrepair Customer Self Repair HP Produkte enthalten viele CSR Teile Customer Self Repair um Reparaturzeiten zu minimieren und h here Flexibilit t beim Austausch defekter Bauteile zu erm glichen Wenn HP oder ein HP Servicepartner bei der Diagnose feststellt dass das Produkt mithilfe eines CSR Teils repariert werden kann sendet Ihnen HP dieses Bauteil zum Austausch direkt zu CSR Teile werden in zwei Kategorien unterteilt Zwingend Teile f r die das Customer Self Repair Verfahren zwingend vorgegeben ist Wenn Sie den Austausch dieser Teile von HP vornehmen lassen werden Ihnen die Anfahrt und Arbeitskosten f r diesen Service berechnet Optional Teile fiir die das Customer Self Repair Verfahren optional ist Diese Teile sind auch f r Customer Self Repair ausgelegt Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen m chten k nnen bei diesem Service je nach den f r Ihr Produkt vorgesehenen Garantiebedingungen zus tzliche Kosten anfallen HINWEIS Einige Teile sind nicht f r Customer Self Repair ausgelegt Um den Garantieanspruch des Kunden zu erf llen muss das
24. see HP ROM Based Setup Utility on page 95 The server also can operate in independent channel mode or combined channel mode lockstep When running in lockstep mode you gain reliability in one of two ways e If running with UDIMMs built with x8 DRAM devices the system can survive a complete DRAM failure SDDC In independent channel mode this failure would be an uncorrectable error e Ifrunning with RDIMM built with x4 DRAM devices the system can survive the complete failure of two DRAM devices DDDC Running in independent mode the server can only survive the complete failure of a single DRAM device SDDC Maximum capacity omae Diver One proceser Iwo proceso RDIMM Single rank 96 GB 192 GB OMM 72 ZE OM uodo 28468 768 68 UDIMM Single rank 32 GB 64 GB UD Dork fore 128 For the latest memory configuration information see the QuickSpecs on the HP website http www hp com Advanced ECC memory configuration Advanced ECC memory is the default memory protection mode for this server Standard ECC can correct single bit memory errors and detect multi bit memory errors When multi bit errors are detected using Standard ECC the error is signaled to the server and causes the server to halt Advanced ECC protects the server against some multi bit memory errors Advanced ECC can correct both single bit memory errors and 4 bit memory errors if all failed bits are on the same DRAM device on the DIMM Advanced E
25. sets the system to its original factory state deletes the current hardware configuration information including array setup and disk partitioning and erases all connected hard drives completely Refer to the instructions for using this utility The Erase utility enables you to erase system CMOS NVRAM and hard drives Run the Erase Utility if you must erase the system for the following reasons e You want to install a new operating system on a server with an existing operating system e You encounter an error when completing the steps of a factory installed operating system installation To access the Erase Utility click the Perform Maintenance icon from the Intelligent Provisioning home screen and then select Erase Run the Erase utility to e Reset all settings erases all drives NVRAM and RBSU e Reset all disks erases all drives e Reset RBSU erases current RBSU settings After selecting the appropriate option click Erase System Click Exit to reboot the server after the erase task is completed Click Cancel Erase to exit the utility without erasing Software and configuration utilities 93 Scripting Toolkit The Scripting Toolkit is a server deployment product that enables you to build an unattended automated installation for high volume server deployments The Scripting Toolkit is designed to support ProLiant BL ML DL and SL servers The toolkit includes a modular set of utilities and important documentation
26. that describes how to apply these tools to build an automated server deployment process The Scripting Toolkit provides a flexible way to create standard server configuration scripts These scripts are used to automate many of the manual steps in the server configuration process This automated server configuration process cuts time from each deployment making it possible to scale rapid high volume server deployments For more information and to download the Scripting Toolkit see the HP website hitp www hp com go ProLiantSTK HP Service Pack for ProLiant SPP is a release set that contains a comprehensive collection of firmware and system software components all tested together as a single solution stack for HP ProLiant servers their options BladeSystem enclosures and limited HP external storage SPP has several key features for updating HP ProLiant servers Using HP SUM as the deployment tool SPP can be used in an online mode on a Windows or Linux hosted operating system or in an offline mode where the server is booted to the ISO so that the server can be updated automatically with no user interaction or updated in interactive mode For more information or to download SPP see the HP website http www hp com go spp HP Smart Update Manager The HP SUM provides intelligent and flexible firmware and software deployment This technology assists in reducing the complexity of provisioning and updating HP ProLiant Servers options
27. the corresponding processor is installed e When two processors are installed balance the DIMMs across the two processors e White DIMM slots denote the first slot of a channel Ch 1 A Ch 2 B Ch 3 C Ch 4 D e Do not mix LRDIMMs UDIMMs or RDIMMs e Do not install more than two UDIMMs per channel UDIMMs should not be installed in slots Ch 1 1 Ch 2 J Ch 3 K or Ch 4 L e When two processors are installed install the DIMMs in sequential alphabetical order balanced between the two processors P1 A P2 A P1 B P2 B P1 C P2 C and so on For detailed memory configuration rules and guidelines use the Online DDR3 Memory Configuration Tool on the HP website http www hp com go ddr3memory configurator DIMM speeds are supported as indicated in the following table Populated slots Speeds supported MT s per channel Single or dual rank 1333 1600 hd Otodrork Advanced ECC population guidelines For Advanced ECC mode configurations observe the following guidelines e Observe the general DIMM slot population guidelines on page 51 e DIMMs may be installed individually Hardware options installation 51 Online spare population For online spare memory mode configurations observe the following guidelines Observe the general DIMM slot population guidelines on page 51 Each channel must have a valid online spare configuration Each channel can have a different valid online spare configuration Each popu
28. 0 seconds During that interval the controller transfers the cached data from DDR memory to flash memory where the data remains indefinitely or until a controller retrieves the data Z CAUTION The cache module connector does not use the industry standard DDR3 mini DIMM pinout Do not use this controller with cache modules designed for other controller models because the controller can malfunction and you can lose data Also do not transfer this cache module to an unsupported controller model because you can lose data Z CAUTION To prevent a server malfunction or damage to the equipment do not add or remove the battery pack while an array capacity expansion RAID level migration or stripe size migration is in progress Z CAUTION After the server is powered down wait 15 seconds and then check the amber LED before unplugging the cable from the cache module If the amber LED blinks after 15 seconds do not remove the cable from the cache module The cache module is backing up data and data is lost if the cable is detached iy IMPORTANT The battery pack might have a low charge when installed In this case a POST error message is displayed when the server is powered up indicating that the battery pack is temporarily disabled No action is necessary on your part The internal circuitry automatically recharges the batteries and enables the battery pack This process might take up to four hours During this time the cache module functions p
29. CC provides additional protection over Standard ECC because it is possible to correct certain memory errors that would otherwise be uncorrected and result in a server failure Using HP Advanced Memory Error Detection technology the server provides notification when a DIMM is degrading and has a higher probability of uncorrectable memory error Hardware options installation 50 Online Spare memory configuration Online spare memory provides protection against degraded DIMMs by reducing the likelihood of uncorrected memory errors This protection is available without any operating system support Online spare memory protection dedicates one rank of each memory channel for use as spare memory The remaining ranks are available for OS and application use If correctable memory errors occur at a rate higher than a specific threshold on any of the non spare ranks the server automatically copies the memory contents of the degraded rank to the online spare rank The server then deactivates the failing rank and automatically switches over to the online spare rank Lockstep memory configuration Lockstep mode provides protection against multi bit memory errors that occur on the same DRAM device Lockstep mode can correct any single DRAM device failure on x4 and x8 DIMM types The DIMMs in each channel must have identical HP part numbers General DIMM slot population guidelines Observe the following guidelines for all AMP modes e Install DIMMs only if
30. Extend the server from the rack on page 21 Remove the access panel on page 22 Cabling 86 Z WARNING Eliminate the risk of electric shock by removing all AC power from the system before installing or replacing any non hot plug hardware option Disconnect all power cords to completely remove power from the server A WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them We IMPORTANT Itis necessary to remove the PCI riser cage only if there is a full length expansion board installed 5 Release the full length expansion board retainer and then remove the PCI riser cage Cs DP Remove the air baffle on page 30 Remove the fan cage Remove the hot plug fan cage on page 24 Disconnect any SAS cables from the hard drive cage and either the embedded SAS controller or an optional SAS controller Do not disconnect the power cable Cabling 87 9 Disconnect the SATA cable from the optical drive and the SATA connector on the system board The optical bay is disabled with the chipset SATA cable option 10 Connect the chipset SATA cable a Connect the chipset SATA cable connector to the chipset SATA controller port on the system board The chipset SATA connector on the SATA cable is narrower than the chipset SATA controller port header on the system board b Connect the remaining chipset SATA cable connector to the SATA hea
31. FF model ATA optical drive bay Systems Insight Display USB connectors 2 3 Drive bays box 2 Systems Insight Display USB connectors 2 s 5 Component identification 7 e FF model Front panel LEDs and buttons iem peseiro 1 Aggregate network LED Off No network link Solid green Link to network Flashing green Network activity Component identification 8 fom Deepen we SS System health LED Solid Green Normal Flashing Amber System degraded Flashing Red System critical To identify components in degraded or critical state see Systems Insight Display LEDs on page 10 UID LED and button Off Deactivated Solid Blue Activated Flashing Blue System being remotely managed Power On Standby button Off Power cord not attached or power supply failure and system power LED Solid Amber System is in standby Power On Standby Button service is initialized Flashing Green Power On Standby Button has been pressed system is waiting to power on Solid Green System on Access the Systems Insight Display To access the HP Systems Insight Display in a server with a LFF configuration 1 Press and release the panel 2 After the display fully ejects rotate the display downward to view the LEDs 3a Component identification 9 Systems Insight Display LEDs The HP Systems Insight Display LEDs represent the system board layout The display enables diagnosis wi
32. HP ProLiant DL380p Gen8 Server User Guide Abstract This document is for the person who installs administers and troubleshoots servers and storage systems HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels Part Number 661848 001 March 2012 Edition 1 Copyright 2012 Hewlett Packard Development Company L P The information contained herein is subject to change without notice The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services Nothing herein should be construed as constituting an additional warranty HP shall not be liable for technical or editorial errors or omissions contained herein Microsoft Windows and Windows Server are U S registered trademarks of Microsoft Corporation Bluetooth is a trademark owned by its proprietor and used by Hewlett Packard Company under license Contents Companen PINT ssl ca eneee e E A Z Front panel COMPOMENTS csscccessscessseecsseeeesseeesseeecsseeeeseeeesseeeesseeeesseeesseeecsseeeseeeesseescsseeeesesesseeseseeesssesenseees 7 Front panel LEDs and bUHONS cccccccccecssscessececssececsseeeeseeecsseeeseeeceeeecseeesseeeeeseeecsseeesseeeesseeecsecestsesesseeessseees 8 Access the Systems Insight Display cinssavcssessesssnnssnengetnoosnnnsnnscunssuansvensennsunntondsuassdsssnsesuessnousenasnssrncsunnse
33. OST e RBSU e Diagnostics e DOS e Operating environments which do not provide native USB support Redundant ROM support The server enables you to upgrade or configure the ROM safely with redundant ROM support The server has a single ROM that acts as two separate ROM images In the standard implementation one side of the ROM contains the current ROM program version while the other side of the ROM contains a backup version NOTE The server ships with the same version programmed on each side of the ROM Safety and security benefits When you flash the system ROM ROMPagq writes over the backup ROM and saves the current ROM as a backup enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason This feature protects the existing ROM version even if you experience a power failure while flashing the ROM Software and configuration utilities 99 Keeping the system current Drivers IMPORTANT Always perform a backup before installing or updating device drivers The server includes new hardware that may not have driver support on all OS installation media If you are installing an Intelligent Provisioning supported OS use Intelligent Provisioning on page 92 and its Configure and Install feature to install the OS and latest supported drivers If you do not use Intelligent Provisioning to install an OS drivers for some of the new hardware are required These drivers as well as
34. S to invoke the NMI handler and generate a crash dump log the administrator can use the iLO Virtual NMI feature For more information see the white paper on the HP website http h20000 www2 hp com bc docs support SupportManual c00797875 c00797875 pdf DIMM slot locations DIMM slots are numbered sequentially 1 through 12 for each processor The supported AMP modes use the letter assignments for population guidelines a Ch3 Ch4 Ch2 Chl Ch3 Ch4 Ch2 Chl f I 1 mm WF dir 41rd rarna CGKDHL JFBIEAICGKDHL JFBIEA A Beer e R II Ii II Ii i li I Ii I Ii I Ii i i RCI EEEH ELLE 1123456 _ 789102123456 78910012 Component identification 16 SAS and SATA device numbers e SFF device bay numbering e Optional SFF device bay numbering E Box w a e LFF device bay numbering Solid blue The drive is being identified by a host application Component identification 17 Definition Flashing blue The drive carrier firmware is being updated or requires an update Off No drive activity The drive is rebuilding or performing a RAID migration stripe size migration capacity expansion or logical drive extension or is erasing Flashing The drive is a member of one or more logical drives and predicts ambe
35. SP YS gt When prompted during the startup sequence access RBSU by pressing the F9 key From the Main Menu select Server Security From the Server Security Menu select Trusted Platform Module From the Trusted Platform Module Menu select TPM Functionality Select Enable and then press the Enter key to modify the TPM Functionality setting Hardware options installation 81 6 Press the Esc key to exit the current menu or press the F10 key to exit RBSU 7 Reboot the server 8 Enable the TPM in the OS For OS specific instructions see the OS documentation Z CAUTION When a TPM is installed and enabled on the server data access is locked if you fail to follow the proper procedures for updating the system or option firmware replacing the system board replacing a hard drive or modifying OS application TPM settings For more information on firmware updates and hardware procedures see the HP Trusted Platform Module Best Practices White Paper on the HP website http www hp com support For more information on adjusting TPM usage in Bitlocker see the Microsoft website http technet microsoft com en us library cc732774 aspx Hardware options installation 82 Cabling SAS hard drive cabling SFF hard drive cabling SFF cabling with optional drive cage Cabling 83 LFF hard drive cabling Cabling 84 FBWC cabling 8 or 16 drive SFF 8 drive LFF PCle option Cabling 85 Depending on th
36. SR StS PAR IN EARTE ER EEEE AIRES HP BIH BH HP BUY FULCAR ASAT ASAI S MH FS A RSS BH ALAS o HN FARTHER NSH EA o BH SHEARS AB TMHE ZA Ma A RIEBR HP BEB gt RUA RE Rt BRERA RAPA OA gt ims Atlee AIR AR ALM Hiit AE HP SARA BRS A ATMS EEt AAASARA HP RMA SRS f BXSAEETMSHBRH META Bs FEO ENS RBI Cat AA FO CSR PHR F ALIAR o TERRA Tet FRAO JARRA XE gt AIR REB SAA MBA ABS TAE H RER gt PATRAS Basia RRA o TMB RHSH EA LARA gt HP ABER CSR BRB 4 PBK A MA Pa e ASIANS HRA HP AGEN RRRIA GERAD 5 ALFER RRF ASE HP Faia AY SS 411478 Be 5 BS ARI AI ABR Bis o MRR ARRAS gt HP ARES UES o HEARTH gt HP HBRMABRREARERAUEE EA ARINE HAR WE HP K SAB THHE ARAMA ERA ERR HER oe BIHAR SH HP th http www hp com go selfrepair a FE HP AES 42 AZS ASD ABO UE FE DA AS 834S WHS YES H7 Aal DA AZ SECR FBS Ch 4SH AAAGH AEH 712 5 HPE HP MWA BSA EE Mtl A BHAYANA CSR FES ASSO F217 THSSICHD HESH HPE aS FSS we APS AOL SUO ASAP DASE gt USS SLICE CSR FEAE F SHI LAUC IAU SA OF AO BI E ALS AHI HPO o FSO DAS QA AS o At Ao cst Su YATE APHC DAAE FA MEY AION AB 0 FESS D2 A HEI SHES AAAA SHa NSARE HPO O FES DAS QAY AP ASA POS MSO ASHE KS AHA Fal He IHS QO MAE HSE AAU HD UY HP Ye D7 ME 4217 BSS AAAA HE SAAS DY HSS oa ZA MUA SUAS SA FSS DASHES SHD USUCH 01218 FSS 2 Illustrated Paris Catalogo No EASA AGUC CSR HBS MD YEY REA TUO ASHE SP CS AAY HEO 755E MSO FAAUE RIRIH
37. Software and configuration utilities 97 ACU is now available as an embedded utility starting with HP ProLiant Gen8 servers To access ACU use one of the following methods e If an optional controller is not installed press F10 during boot e If an optional controller is installed when the system recognizes the controller during POST press F5 For optimum performance the minimum display settings are 1024 x 768 resolution and 16 bit color Servers running Microsoft operating systems require one of the following supported browsers e Internet Explorer 6 0 or later e Mozilla Firefox 2 0 or later For Linux servers see the README TXT file for additional browser and support information For more information about the controller and its features see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website http bizsupport2 austin hp com bc docs support SupportManual c01608507 c01608507 pdf To configure arrays see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website http bizsupport austin hp com bc docs support SupportManual c00729544 c00729544 pdf Option ROM Configuration for Arrays Before installing an operating system you can use the ORCA utility to create the first logical drive assign RAID levels and establish online spare configurations The utility also provides support for the following functions e Reconfiguring one or more logical drives e Viewi
38. T ELOR HRV LT FAV VCCI B VCCI y ASV YT WRU AIL ROW CERF SY CORBIS TAA ATARI CH ORE 2 ERE CHATS bE RGB SRIPF IC EMHVET COBSICIHAA HORM RAT HLIBRENSIEMHVET VCCI A BSMI notice Sa PAA ia e PRS St aNedo BER Tae He AAS gt ORE BISA TE FEST gt ASS ERRAR EHR Korean notice Class A equipment O NDE SISBADLL HAMAR SSS St 20LU WA E ASAE 0 SS FASHA BeH 2 29 AJAN AS5HE AS SACS HUC AS J Ges SS Regulatory compliance notices 107 Class B equipment Ol AAS IASB AAUABSSS St INZA F JAA ASSE AS SACS H TE AAAA At 8 4 SUC 8S JI Os 2547 2 Chinese notice Class A equipment pe ay WA ARP ih TESTED BPA RAMA BK ERR WHER PAP RAR 1TH HE Laser compliance This product may be provided with an optical storage device that is CD or DVD drive and or fiber optic transceiver Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825 1 The product does not emit hazardous laser radiation Each laser product complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 and with IEC 60825 1 2007 A WARNING Use of controls or adjustments or performance of procedures other than those specified herein or in the laser product s installation guide may result in hazardous radiation exposure To reduce the risk of exposure to hazardous radiation e D
39. To run this utility boot the server using Intelligent Provisioning on page 92 HP Insight Diagnostics Online Edition is a web based application that captures system configuration and other related data needed for effective server management Available in Microsoft Windows and Linux versions the utility helps to ensure proper system operation For more information or to download the utility see the HP website http www hp com servers diags HP Insight Diagnostics Online Edition is also available in the SPP For more information see the HP website hitp www hp com go spp download HP Insight Diagnostics survey functionality HP Insight Diagnostics on page 93 provides survey functionality that gathers critical hardware and software information on ProLiant servers This functionality supports operating systems that are supported by the server For operating systems supported by the server see the HP website http www hp com go supportos If a significant change occurs between data gathering intervals the survey function marks the previous information and overwrites the survey data files to reflect the latest changes in the configuration Survey functionality is installed with every Intelligent Provisioning assisted HP Insight Diagnostics installation or it can be installed through the SPP HP Service Pack for ProLiant on page 94 Erase Utility Z CAUTION Perform a backup before running the System Erase Utility The utility
40. WEE ARANEAE ENTALES KRAO CSR RE tS BIS IS MAAS SHPIIRATSVRMHSMDEIMOMRRENTHWES MMAR CHP ETF SVBBMHOPBAIL HEMIRA GHRISSSRAUA MMAR SHPIIRIALTC ESL MMA ER STARA BOCROMARICMBBRt CBICANTC EEL RBS BRELCU BS HPA ORAB AWAR NET ME BCHHORICIS HAAS LUMRRARESRRL PAS DERES OES SteBELET P ATEI HP ante hit S amp P ATHENS CSR ABE LS By RE MRA HENS PY 5 ANE E RRA ERB ARR Tate MRS ETA HP Cok HP ARS HERR ARB AEA WATER LEA CSR ABE TEMES HP 43 EFI B IA ABE AIK SA EET EIR APRA CSR ABH RIED BXEAWMATHEIEM A WRIA HP BRIAR MMMABMRSERNZ ie AOA THA BN SANA SE A THEM RERAHEARABITHERITN Fit MRE ER HP AG BIRR MARGE A AI Gade EAI RIS AR SS SEW HP A REKREA RE AT Min 3 FA iE RE HP MAMIRIHHAS ERA ATH ATMERA RENE HP ERRER EAS S RAAB RERAFERAAMAR PICA BE CSR BAER TIF ARE MATERA OBE ARTHNBEAA WES ARO HAR BRERA RA URGRBH GARE HP RALPH HSARKA AB Bik A HERR HP AEEA CSR ABA AeA R h E AE IS A BR YB i I SR HP MRK IS A RA AIBA IDES HP PBACUOMEM EM IRA OREA 5 SLA 1 HERBES HP FA GRP AT AB EV AB THe HE AY A iH R R AARE MRARCIALAR BARUABAE HP ARES RRR ERR EA BITER HP HREM AAK EMRE RA HEERS AX H SAB THEMES A5 HRR ESR SRAM ia HP Mth http www hp com go selfrepair Technical support 121 P BTIMHE H HP makat Sat SR ATHHEs CSR FLOR DESSE gt Wh BRS RRRS BA RIIETE o ANERTEECEAABIE HP ER HP ARISE ERMHE RSE HERMES T fF A AEEA CSR E RER Bll HP HS BETA RLS AAG EE EIR C
41. a p riode de diagnostic HP ou ses partenaires ou mainteneurs agr s d termine que la r paration peut tre effectu e l aide d une pi ce CSR HP vous l envoie directement Il existe deux cat gories de pi ces CSR Obligatoire Pieces pour lesquelles la r paration par le client est obligatoire Si vous demandez a HP de remplacer ces pi ces les co ts de d placement et main d uvre du service vous seront factur s Facultatif Pieces pour lesquelles la r paration par le client est facultative Ces pi ces sont galement con ues pour permettre au client d effectuer lui m me la r paration Toutefois si vous demandez HP de remplacer ces pi ces l intervention peut ou non vous tre factur e selon le type de garantie applicable a votre produit REMARQUE Certaines pi ces HP ne sont pas con ues pour permettre au client d effectuer lui m me la r paration Pour que la garantie puisse s appliquer HP exige que le remplacement de la pi ce soit effectu par un Mainteneur Agr Ces pi ces sont identifi es par la mention Non dans le Catalogue illustr Les pi ces CSR sont livr es le jour ouvr suivant dans la limite des stocks disponibles et selon votre situation g ographique Si votre situation g ographique le permet et que vous demandez une livraison le jour m me ou dans les 4 heures celle ci vous sera factur e Pour b n ficier d une assistance t l phonique appelez le Centre d assistance technique HP Dan
42. a processor with a faster speed update the system ROM before installing the processor To install a processor 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Hardware options installation 40 5 If any full length PCI riser boards are installed release the full length expansion board retainer and then remove the PCI riser cage Peery z 6 Remove the air baffle on page 30 7 Open the heatsink retaining bracket and then remove the blank Z CAUTION The pins on the processor socket are very fragile Any damage to them may require replacing the system board Hardware options installation 41 8 Open each of the processor locking levers in the order indicated and then open the processor retaining bracket 9 Remove the clear processor socket cover Retain the processor socket cover for future use Hardware options installation 42 10 Install the processor Verify that the processor is fully seated in the processor retaining bracket by visually inspecting the processor installation guides on either side of the processor THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED Z CAUTION THE PINS ON THE SYSTEM BOARD ARE VERY FRAGILE AND EASILY DAMAGED To avoid damage to the system board do not touch th
43. alabra No en el cat logo ilustrado de componentes Seg n la disponibilidad y la situaci n geogr fica los componentes CSR se enviar n para que lleguen a su destino al siguiente dia laborable Si la situaci n geogrdfica lo permite se puede solicitar la entrega en el mismo d a o en cuatro horas con un coste adicional Si precisa asistencia t cnica puede llamar al Centro de asistencia t cnica de HP y recibir ayuda telef nica por parte de un t cnico Con el env o de materiales para la sustituci n de componentes CSR HP especificar si los componentes defectuosos deber n devolverse a HP En aquellos casos en los que sea necesario devolver alg n componente a HP deber hacerlo en el periodo de tiempo especificado normalmente cinco d as laborables Los componentes defectuosos deber n devolverse con toda la documentaci n relacionada y con el embalaje de env o Si no enviara el componente defectuoso requerido HP podr cobrarle por el de sustituci n En el caso de todas sustituciones que lleve a cabo el cliente HP se har cargo de todos los gastos de envio y devoluci n de componentes y escoger la empresa de transporte que se utilice para dicho servicio Technical support 118 Para obtener mas informaci n acerca del programa de Reparaciones del propio cliente de HP p ngase en contacto con su proveedor de servicios local Si est interesado en el programa para Norteam rica visite la pagina web de HP siguiente http www hp c
44. ance features are unique with HP SmartMemory HP SmartMemory 1 35V DDR3 1333 Registered memory is engineered to achieve the same performance level as 1 5V memory For example while the industry supports DDR3 1333 RDIMM at 1 5V this Gen8 server supports DDR3 1333 RDIMM up to 3 DIMMs per channel at 1066 MT s running at 1 35V This equates to up to 20 less power at the DIMM level with no performance penalty In addition the industry supports UDIMM at 2 DIMMs per channel at 1066 MT s HP SmartMemory supports 2 DIMMs per channel at 1333 MT s or 25 greater bandwidth Memory subsystem architecture The memory subsystem in this server is divided into channels Each processor supports four channels and each channel supports three DIMM slots as shown in the following table i B F J C G K D H L For the location of the slot numbers see DIMM slot locations on page 16 This multi channel architecture provides enhanced performance in Advanced ECC mode This architecture also enables Lockstep and Online Spare Memory modes DIMM slots in this server are identified by number and by letter Letters identity the population order Slot numbers indicate the DIMM slot ID for spare replacement Single dual and quad rank DIMMs To understand and configure memory protection modes properly an understanding of single dual and quad rank DIMMs is helpful Some DIMM configuration requirements are based on these classifications A single
45. appears Warning The Product ID should ONLY be modified by qualified service personnel This value should always match the Product ID on the chassis Enter the product ID and press the Enter key Press the Esc key to close the menu Press the Esc key to exit RBSU Press the F10 key to confirm exiting RBSU The server automatically reboots Utilities and features Array Configuration Utility ACU is a browser based utility with the following features Runs as a local application or remote service accessed through the HP System Management Homepage Supports online array capacity expansion logical drive extension assignment of online spares and RAID or stripe size migration Suggests the optimum configuration for an unconfigured system For supported controllers provides access to licensed features including o Moving and deleting individual logical volumes o Advanced Capacity Expansion SATA to SAS and SAS to SATA o Offline Split Mirror o RAID 6 and RAID 60 o RAID 1 ADM and RAID 10 ADM o HP Drive Erase o Video On Demand Advanced Controller Settings Provides different operating modes enabling faster configuration or greater control over the configuration options Remains available any time that the server is on Displays on screen tips for individual steps of a configuration procedure Provides contextsensitive searchable help content Provides diagnostic and SmartSSD Wear Gauge functionality on the Diagnostics tab
46. are For customers running business critical environments where down time is not an option then HP Proactive Care helps to deliver high levels of application availability Key to these service options is the delivery of proactive service management offers to help you avoid the causes of down time If a problems arises than HP offers advanced technical response from critical system support specialist for fast problem identification and resolution HP Support Center All service options include HP Support Center delivering information tools and experts required to support HP business products HP Insight Remote Support Provides 24x7 secure remote monitoring diagnosis and problem resolution For more information see the HP website hitp www hp com services proliant or the HP website for the HP BladeSystem http www hp com services bladesystem Change control and proactive notification HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products For more information refer to the HP website hitp www hp com go pcn Software and configuration utilities 101 Troubleshooting Troubleshooting resources The HP Proliant Gen8 Troubleshooting Guide Volume I Troubleshooting provides procedures for resolving common problems and comprehensive courses of action for fault isolation and identification issue resolution and s
47. at up to 1600 MT s e Single and dual rank PC3 10600 DDR 1333 UDIMMs operating at up to 1333 MT s e Quad rank PC3L 10600 DDR3 1333 LRDIMMs operating as dual rank DIMMs at up to 1333 MT s Speed voltage and capacity DIMM type DIMM rank DIMM capacity Native speed MT s Voltage RDIMM alia 8 GB 1600 STD DIMM 1393 UDIMM 1333 CA Depending on the processor model the number of DIMMs installed and whether LRDIMMs UDIMMs or RDIMMs are installed the memory clock speed can be reduced to 1333 or 1066 MT s Populated DIMM speed MT s DIMM ype DA rank 1 DIN par channel 2 DIM por channel 3 DIMMs por charn ma poe an Dekk 13354 RDIMM supports 1 35V 3DPC at 1066 Third party memory supports 1 5V 3DPC at 1066 LRDIMM enables 3 DIMMs per channel HP SmartMemory supports up to 3DPC at 1066 MT s at 1 35V Third party memory supports 1 5V only t UDIMM is supported at 2DPC at 1333 MT s using HP SmartMemory only Third party memory supports up to 2DPC at 1066 MT s Hardware options installation 47 HP SmartMemory HP SmartMemory introduced for Gen8 servers authenticates and unlocks certain features available only on HP Qualified memory and verifies whether installed memory has passed HP qualification and test processes Qualified memory is performance tuned for HP ProLiant and BladeSystem servers and provides future enhanced support through HP Active Health and manageability software Certain perform
48. ber of service level options are available to meet your needs HP Care Pack Services offer upgraded service levels to expand your standard product warranty with easy to buy easy to use support packages that help you make the most of your server investments Some of the Care Pack services are e Hardware support 0 0 6 Hour Call to Repair 4 Hour 24x7 Same Day 4 Hour Same Business Day e Software support o Microsoft Linux HP ProLiant Essentials HP SIM and RDP VMWare e Integrated hardware and software support o 0 o o e Startup and implementation services for both hardware and software For more information on HP Care Pack Services see the HP website Critical Service Proactive 24 Support Plus Support Plus 24 hitp www hp com services carepack Rack planning resources The rack resource kit ships with all HP branded or Compaq branded 9000 10000 and H9 series racks For more information on the content of each resource see the rack resource kit documentation Optimum environment When installing the server in a rack select a location that meets the environmental standards described in this section Setup 32 Space and airflow requirements To allow for servicing and adequate airflow observe the following space and airflow requirements when deciding where to install a rack e Leave a minimum clearance of 63 5 cm 25 in in front of the rack e Leave a min
49. casos em que isso for necess rio preciso enviar a pe a com defeito HP dentro do per odo determinado normalmente cinco 5 dias teis A pe a com defeito deve ser enviada com a documenta o correspondente no material de transporte fornecido Caso n o o fa a a HP poder cobrar a reposi o Para as pe as de reparo feito pelo cliente a HP paga todas as despesas de transporte e de devolu o da pe a e determina a transportadora servi o postal a ser utilizado Para obter mais informa es sobre o programa de reparo feito pelo cliente da HP entre em contato com o fornecedor de servi os local Para o programa norte americano visite o site da HP http www hp com go selfrepair Technical support 120 ms ACRE RIES EA ERREAL AEROLIT St SRORRMESHRT OH HRR SAORA AAS CSR MRANHVET BEOR CST EEA NEEE TED EHP HEHEH ERRTREE AB L t WS HISTOMMREBR BERTEL SHMICRMLUIEESET CSRBRIMILUAFO 23H Y NH Y eT DA BSRCCEADAOBR HARRIOT FE LES BAHIA ERERMENSHAICIX FO SHY EAI SRBREKVAFRMESRCBRENET E REECCEMER THOMA COMMEMERCBEATY MkMMICOLT ELESBRAHPIC SAVER EAA SHSMAILIS SRUOLTORRICMASH SREY ECANROMAANICKW TS ARARA SRL TUM TER REY ERERITSCEMTEET HPRRO MOMMIs REACCBRACSHVECA MOREL MIRT OTDI HEHEH IER RPGS EOIR RAWALVES MRAP OTICMS SRPMS ACCRA CHS SAM EMTWET SPRATT RES A Hho ko Tk CSREES EJALET KK Rko TIE IBMRASABUEE lt CEI SF YAREHALLI A EEEREN YET AR FABRE SIL HOBBS RO BRL T
50. ccceceseccssscecesececeseeeeeeecsseeeceseeeeeeeeeeeeecseeesseeeesseeesseceseeecsseeecesesecseeesseescssesessseeeesaeees 90 HP iLO Management Engine eeeeeeesscceeeeceeeeeeeenseeeeceeeeeeennneeeeeecesseeesnaeeeeeeeeseeeennaeeeeeeeeseeennaeeeeeeeeee 90 MO HARHAA RARAHI Git ce cbeaa tea banys 90 Intelligent Provisioning pererereeererrcerrerr tee eererterrere rer rerertrerirerereterrcrrrerrrter renter ryererr rer evrr tc eevee ree 92 Erase Utility c cccccccccccssececsseceesececsseceeseceesececsseceseeeesseeecseeeseeecsseeeceseeessseeesseeeceseceseeecsseeessseeeseaaes 93 Scripting Toolkit sassssssseisssirartesasrarsrantesnteasdaahsrasdriadraateaamasinastraadsdadeasdaaadiaadesnteaiauaedrasdnciabseaissavensiets 94 HP Service Pack for Proliant ccccsscesseeesseeeseeeseeseecaeceseeeeecaeeeseeceeceeeeaeeeseecnseeeseesueeenaeenseeenseenseseeeeteess 94 HP Smart Update Manager iassssssissssasbnsesssnacnrsandseetsasinenisatinassnasendeinnseiaeaseisissdeiniaamaiabiaabiiaiaasess 94 Contents 4 HP ROM Based Setup Utility ccccccccccsscccsscecsseceesseeesseccesseceseecceseeeesseeesssesesseeesseeeeseeeesseeesssesesseesenseeensaes 95 Using RESU siea iae e dee Stites deans a a E e Sines suds E e a e N a E E EE 95 Auto configuration PROCESS lt lt s lt scieucsencteaahesaocsadsusbiesbassaayaausasosadasaaadasassaasadashcedabavasaadadasstasgassesaeedassaden 95 BOGE OD ONS sa aciaa aaa E ta aac aadenaanaadanaamaaasamasdadectasaaneiaaadaadce saa aneaa
51. ceseceseeeneeenseeseeseeseaeseneeeneeennees 56 Installing the flash backed write cache capacitor pack ccceseeseeesseeeseceeeeeeeeeeenseeeeeeteeenseeeeeeneeenaees 57 Optical drive Option ccccccccccsscccsseceesseeeeseeecseceeseeeceeeecsseeeeeeecseeesseeeeseeecsseeeesseessseescseeeseeeesseeeceseeeseaeees 59 Redundant hot plug power supply Option cccsccesseesteeeseeeeeeeeseeeseeceecseeseaeeeeeenaeesseeseeenseseseeeneeenseeeeseneeees 61 dey lt h Ve 9 fe ener ereReEcr reer orrecr reer ryerererrcrrrerercreperery i reerercrrrenreyererrytrrvepercrerertrt revert rereenyt se rtyt re Seater 62 Expansion board options ccccccsscccssscecsseecesececssecesseeeseeecssececseeeeseeeceseeeseeeeeeeecsseeeseeecssececsseeessseessseeessaes 64 Removing the expansion slot blanks cc ccesceesseeeseeeseeeeeceeeenseeeeeeeeceseeeeeeneeenseeeaeecnseseaeeeteeneeseaees 64 Installing a half length expansion board cecceesseeeseeeseeeeeeeeeeeeseeeeecneeceseceeeeneeenseeeeeetreseaeeenteeneeenaees 65 Installing a full length expansion board cccecceeseeeseceseeeseeenseceseesseeeeeceaeeeeeeneeenseseaeeseeseseseteeneeeenees 66 Secondary PCI riser cage OPtion ceecceeccesseeeseeeseeceseeeseeeeecneeceseeeeeceeeeeaeeeeeeecseseaeeeneeseseeeeesueesnseeeeeeneeenaees 67 Hard drive cage Option asvacanavocnsanstinsatinn snasaeoeamnesepeaenestianateon ctanstanstasaeas sunsswassuassuaraunceusestaestauseousenstiasstasseeseanss 69 2U rack bezel Optio
52. cker always retain the recovery key password The recovery key password is required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity Hardware options installation 79 e HP is not liable for blocked data access caused by improper TPM use For operating instructions see the encryption technology feature documentation provided by the operating system Installing the Trusted Platform Module board Z WARNING To reduce the risk of personal injury electric shock or damage to the equipment remove the power cord to remove power from the server The front panel Power On Standby button does not completely shut off system power Portions of the power supply and some internal circuitry remain active until AC power is removed A WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Remove the server from the rack if necessary Place the server on a flat level work surface Remove the access panel on page 22 Remove the PCI riser cage on page 27 ae SS SS Remove the air baffle on page 30 Z CAUTION Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet Upon locating a broken or disfigured r
53. continuous quality improvement calls may be recorded or monitored If you have purchased a Care Pack service upgrade see the Support amp Drivers website http www8 hp com us en supportdrivers html If the problem cannot be resolved at the website call 1 800 633 3600 For more information about Care Packs see the HP website hitp pro ag sama houston hp com services cache 10950 0 0 225 121 html Customer Self Repair HP products are designed with many Customer Self Repair CSR parts to minimize repair time and allow for greater flexibility in performing defective parts replacement If during the diagnosis period HP or HP service providers or service partners identifies that the repair can be accomplished by the use of a CSR part HP will ship that part directly to you for replacement There are two categories of CSR parts Mandatory Parts for which customer self repair is mandatory If you request HP to replace these parts you will be charged for the travel and labor costs of this service Optional Parts for which customer self repair is optional These parts are also designed for customer self repair If however you require that HP replace them for you there may or may not be additional charges depending on the type of warranty service designated for your product Technical support 115 NOTE Some HP parts are not designed for customer self repair In order to satisfy the customer warranty HP requires that an authorize
54. d service provider replace the part These parts are identified as No in the Illustrated Parts Catalog Based on availability and where geography permits CSR parts will be shipped for next business day delivery Same day or four hour delivery may be offered at an additional charge where geography permits If assistance is required you can call the HP Technical Support Center and a technician will help you over the telephone HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP In cases where it is required to return the defective part to HP you must ship the defective part back to HP within a defined period of time normally five 5 business days The defective part must be returned with the associated documentation in the provided shipping material Failure to return the defective part may result in HP billing you for the replacement With a customer self repair HP will pay all shipping and part return costs and determine the courier carrier to be used For more information about HP s Customer Self Repair program contact your local service provider For the North American program refer to the HP website http www hp com go selfrepair R paration par le client CSR Les produits HP comportent de nombreuses pi ces CSR Customer Self Repair r paration par le client afin de minimiser les d lais de r paration et faciliter le remplacement des pi ces d fectueuses Si pendant l
55. del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar Customer Self Repair CSR para minimizar el tiempo de reparaci n y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos Si durante la fase de diagn stico HP o los proveedores o socios de servicio de HP identifica que una reparaci n puede llevarse a cabo mediante el uso de un componente CSR HP le enviar dicho componente directamente para que realice su sustituci n Los componentes CSR se clasifican en dos categorias e Obligatorio componentes para los que la reparaci n por parte del usuario es obligatoria Si solicita a HP que realice la sustituci n de estos componentes tendr que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio e Opcional componentes para los que la reparaci n por parte del usuario es opcional Estos componentes tambi n est n dise ados para que puedan ser reparados por el usuario Sin embargo si precisa que HP realice su sustituci n puede o no conllevar costes adicionales dependiendo del tipo de servicio de garantia correspondiente al producto NOTA Algunos componentes no est n dise ados para que puedan ser reparados por el usuario Para que el usuario haga valer su garant a HP pone como condici n que un proveedor de servicios autorizado realice la sustituci n de estos componentes Dichos componentes se identifican con la p
56. delines 53 DIMM slot locations 17 DIMM slots 53 DIMMs 17 50 DIMMs installation 55 DIMMs single and dual rank 50 drive LEDs 19 drivers 104 electrical grounding requirements 36 electrostatic discharge 116 enabling the Trusted Platform Module 85 environmental requirements 35 environmental specifications 117 Erase Utility 93 97 error messages 106 European Union notice 111 expansion board options 67 expansion slot covers 67 expansion slot covers removing 67 expansion slots 67 68 69 extending server from rack 23 F FBWC cabling 88 FBWC module 20 58 FCC rating label 109 features 7 101 Federal Communications Commission FCC notice 109 110 111 front panel buttons 9 front panel components 7 G grounding methods 116 grounding requirements 36 Index 126 H hard drive bays 7 hard drive cage 72 hard drive LEDs 19 hard drives 19 hard drives determining status of 19 hardware options installation 39 42 health driver 103 health LEDs 9 help resources 122 hot plug fans 21 26 hot plug SAS hard drive options 55 HP Insight Diagnostics 96 HP Insight Remote Support software 105 HP Smart Update Manager overview 93 98 HP technical support 105 122 identification number 109 iLO Integrated Lights Out 93 IML Integrated Management Log 93 95 Insight Diagnostics 96 104 installation services 34 installation server options 39 42 installing a hot plug SAS hard drive 56 installing hardware
57. der on the hard drive cage 11 Coil the cables behind the hard drive backplane to minimize airflow impact 12 Install the fan cage Remove the hot plug fan cage on page 24 13 Install the air baffle Remove the air baffle on page 30 14 Install the PCI riser cage on page 28 if removed 15 Secure any full length PCI expansion boards with the retaining latch on the air baffle Secure the full length expansion board retainer on page 29 16 Install the access panel on page 23 Cabling 88 17 Install the server in the rack Installing the server into the rack on page 36 18 Remove any installed hard drives Removing a hot plug SAS or SATA hard drive on page 54 19 Install a SATA hard drive Installing a hot plug SAS or SATA hard drive on page 53 in hard drive bay 5 20 Install hard drive blanks in any empty hard drive bays 21 Connect each power cord to the server 22 Connect each power cord to the power source 23 Power up the server on page 21 24 Using the HP ROM Based Setup Utility on page 95 disable the embedded HP Smart Array P420i Controller if necessary 150W PCle power cable option Z CAUTION To prevent damage to the server or expansion boards power down the server and remove all AC power cords before removing or installing the PCI expansion cage Connect the cable as indicated Cabling 89 Software and configuration utilities Server mode The software and config
58. e component 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Release the full length expansion board retainer and then remove the PCI riser cage Hardware options installation 64 6 Remove the expansion slot blank To replace the component reverse the removal procedure Installing a half length expansion board 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Remove the PCI riser cage on page 27 Remove the expansion slot blank Removing the expansion slot blanks on page 64 eS FS Install the expansion board 8 Connect any required internal or external cables to the expansion board See the documentation that ships with the expansion board Hardware options installation 65 Install the PCI riser cage on page 28 Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 Connect each power cord to the server Connect each power cord to the power source Power up the server on page 21 Installing a full length expansion board 1 2 Power d
59. e following features e Combined diagnostics tools scanners e Always on continuous monitoring for increased stability and shorter downtimes e Rich configuration history e Health and service alerts e Easy export and upload to Service and Support The HP Active Health System monitors and records changes in the server hardware and system configuration The Active Health System assists in diagnosing problems and delivering rapid resolution when server failures occur The Active Health System collects the following types of data e Server model e Serial number e Processor model and speed e Storage capacity and speed e Memory capacity and speed e Firmware BIOS HP Active Health System does not collect information about Active Health System users operations finances customers employees partners or data center such as IP addresses host names user names and passwords HP Active Health System does not parse or change operating system data from third party error event log activities such as content created or passed through by the operating system The data that is collected is managed according to the HP Data Privacy policy For more information see the HP website hitp www hp com go privacy Software and configuration utilities 91 The Active Health System log in conjunction with the system monitoring provided by Agentless Management or SNMP Pass thru provides continuous monitoring of hardware and configuration changes
60. e processor or the processor socket contacts 11 Close the processor retaining bracket When the processor is installed properly inside the processor retaining bracket the processor retaining bracket clears the flange on the front of the socket Z CAUTION Do not press down on the processor Pressing down on the processor may cause damage to the processor socket and the system board Press only in the area indicated on the processor retaining bracket Hardware options installation 43 h processor locking lever e and then close eac etaining bracket etaining bracket in plac indicated on the processor r from the heatsink Remove the thermal interface protective cover 13 installation 44 Hardware options 14 Install the heatsink 15 Remove the two fan blanks N Y y V V WY f N g N N S N Hardware options installation 45 16 Install the two additional fans included with the processor You can install memory Installing a DIMM on page 52 on the second processor HP recommends balancing memory between both processors for improved performance For more information on memory configurations see Memory Options on page 47 17 Install the air baffle Remove the air baffle on page 30 18 Install any full length expansion boards Installing a full length expansion board on page 66 if previously removed 19 Install the access panel on page 23
61. e server configuration you may need to remove the primary PCI riser cage Remove the PCI riser cage on page 27 before cabling to a PCle expansion board Chipset SATA cable option With the chipset SATA cable option the chipset SATA controller can be used with a single SATA hard drive that is installed in one hard drive bay of the SFF or LFF hard drive cage When using the chipset SATA configuration the following conditions apply o Only drive bay 5 is enabled The remaining drive bays are disabled o The optical bay is disabled because the chipset SATA controller port on the system board is redirected from the optical bay to the drive cage o Hard drive status LEDs are not supported o Hard drive thermal status monitoring is not supported o Hotplug operation is not supported Because only one drive bay is enabled all remaining drives can be removed For proper thermal cooling install blanks in all bays that do not have a drive installed Order a sufficient number of 6 35 cm 2 5 in or 8 89 cm 3 5 in hard drive blank option kits from an HP authorized reseller For more information see the server maintenance and service guide The standard SATA driver is included with supported operating systems No additional driver is required To install the component 1 2 Power down the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server
62. ecific page enter the following web address into the browser http www hp com support lt servername gt For example http www hp com support dl360g6 Automatic Server Recovery ASR is a feature that causes the system to restart when a catastrophic operating system error occurs such as a blue screen ABEND does not apply to HP ProLiant DL980 Servers or panic A system fail safe timer the ASR timer starts when the System Management driver also known as the Health Driver is loaded When the operating system is functioning properly the system periodically resets the timer However when the operating system fails the timer expires and restarts the server ASR increases server availability by restarting the server within a specified time after a system hang At the same time the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system You can disable ASR from the System Management Homepage or through RBSU USB support HP provides both standard USB 2 0 support and legacy USB 2 0 support Standard support is provided by the OS through the appropriate USB device drivers Before the OS loads HP provides support for USB devices through legacy USB support which is enabled by default in the system ROM Legacy USB support provides USB functionality in environments where USB support is not available normally Specifically HP provides legacy USB functionality for the following e P
63. ector on the top of the cache module 9 Install one or two FBWC capacitor packs into the FBWC capacitor pack holder 10 Install the FBWC capacitor pack holder into the server Hardware options installation 58 o 8or l6 drive SFF 11 Install the access panel on page 23 12 Install the server into the rack Installing the server into the rack on page 36 13 Connect each power cord to the server 14 Connect each power cord to the power source 15 Power up the server on page 21 Optical drive option 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source Hardware options installation 59 b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Remove the existing media drive option or blank CaDtOCRBDOCOOR 6 Slide the optical drive into the drive bay Hardware options installation 60 7 Connect the power and data cable to the system board and the optical drive Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 10 Connect each power cord to the server 11 Connect each power cord to the power source 12 Power up the server on page 21 Redundant hot plug power supply option Z CAUTION All power supplies installed in the server must have the same output po
64. ed SCSI SATA serial ATA SDDC Single Device Data Correction Acronyms and abbreviations 124 SELV separated extra low voltage SFF small form factor SIM Systems Insight Manager TMRA recommended ambient operating temperature TPM trusted platform module UDIMM Unregistered Dual In Line Memory Module UID unit identification UPS uninterruptible power system USB universal serial bus VCA Version Control Agent Acronyms and abbreviations 125 Index A AC power supply 118 119 120 121 access panel 24 25 Advanced ECC memory 52 54 100 air baffle 32 Array Configuration Utility ACU 101 ASR Automatic Server Recovery 103 authorized reseller 122 auto configuration process 99 Automatic Server Recovery ASR 103 battery 107 114 BIOS upgrade 93 102 blue screen event 17 boot options 100 BSMI notice 113 buttons 7 C cable management arm 26 38 cables 86 111 cabling 86 87 Canadian notice 111 capacitor pack 58 Care Pack 34 105 Change Control 105 Chinese notice 114 components 7 components identification 7 configuration of system 41 93 connectors 7 contacting HP 122 controller 57 crash dump analysis 17 CSR customer self repair 123 customer self repair CSR 122 123 D DC power supply 37 default settings 52 diagnostic tools 93 96 102 103 diagnostics utility 96 DIMM identification 51 DIMM installation guidelines 53 DIMM population gui
65. ed service provider Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales giveaway or promotion Contact a qualified Taiwanese recycler for proper battery disposal Power cord statement for Japan ARZI ARS ni Ba Kk amp BEV FSV AAAS ni E R It HO CEA RE A Regulatory compliance notices 109 Electrostatic discharge Preventing electrostatic discharge To prevent damaging the system be aware of the precautions you need to follow when setting up the system or handling parts A discharge of static electricity from a finger or other conductor may damage system boards or other static sensitive devices This type of damage may reduce the life expectancy of the device To prevent electrostatic damage Avoid hand contact by transporting and storing products in static safe containers Keep electrostatic sensitive parts in their containers until they arrive at static free workstations Place parts on a grounded surface before removing them from their containers Avoid touching pins leads or circuitry Always be properly grounded when touching a static sensitive component or assembly Grounding methods to prevent electrostatic discharge Several methods are used for grounding Use one or more of the following methods when handling or installing electrostatic sensiti
66. eecseeesseeecssesecseeeseeeeesececsseseseesenseeeegs 111 Contents 5 HP 460 W CS HE Power Supply 92 specifications cccccccccssecesseceesecessseeesseeesseeeessesesseeeesseeeess 112 HP 460 W CS Platinum Power Supply 94 specifications ccccccccsscccssscessseecssecessseeessseeenseeeesseeeeas 112 HP 750 W CS HE Power Supply 92 specifications cccccccccssecesssceessecesseeeensecessseeeesseseneeeesseeenss 112 HP 750 W CS Platinum Power Supply 94 specifications ccccccccssccessscessseecssecessseeeesseseseeeesseeess 113 HP 750 W 48V CS Power Supply specifications cccccccsscccsssccssseecssececsseceeeeeceseeessseeeessesenseeeesseeeeas 113 HP 1200 W CS HE Power Supply 90 specifications cccccccsscccssececssecesseeecsseeecsseeeesseeesseeessseeeens 114 rata oak ings E twee a aude gcd a etcadeedee 115 Before you Contact HP cccccsccccsssccssececssecesseeccseeecsseeeseeeecseeeceseeeesseeesseeecseceseesceseeecseeeeseesesseeeessecesseeeees 115 HP contact INformations ee E E E EEE E E R R E A E R E E E RE E E E 115 Customer selRepdir ane aee a setae cesict pce sect scesecn sect ctsict seat ot ce stot Sct steeecestct shes 2h 8 115 Aconyme and Re lsc 2 21 Seer eee ee eee mee eee ee MEE ee EEnTe meee nee Ene SE eee TeEE ere ween ert Terres ere rerert 123 PRI EPE ETA EAA E A E EE E AA eins E atin EE EE EEE AT EEE T T E 126 Contents 6 Component identification Front panel components e S
67. eensecnseeceecnseeeaeeeneeenaeeneenteeensees 29 Remove the air AMM eorecessctancsasesstectuct aes daqhassetectassUcatttat hati acuyacstuctsstttuetssehaaahsaattectsaaytaseeatetucteuceseenseerteadas 30 ID A E A A A A A E T E E E A E A A A EA T 32 Optional installation services cccccccccsscesssecessseecsseeeeseecsseeeesseeessseeesseeeeseeecssececseeeeeseeeesseeessseseeseesenseeessseees 32 Rock planning resoUrceSersre n E ET 32 Optimum environments serena 32 Space and airflow requirements cccccccssscesssccessceesseecesscecseseeeseecesaeecesaeceeaeeceseeeceseeceaeseesaeesesesensaes 33 Temperature TSG Uir erme Nearer e er eE E E E E E E vale vce vale eve WOR ee HU Pee 33 POWER FEQUITEMENTS ecceseni airaa deme teire deme deie tuimeteire demeteie cumeteeeumemeeecumemueecernies 34 Electrical grounding requirements cinii ea ee tantrat eaesresseentenenna 34 Connecting a DC power cable to a DC power sourcen cucu en ee 34 Rack Warnings sce eee 35 Identifying the contents of the server shipping Canen 3 25 4cciseieen sere eu eee ee 36 Installing Nan Ware GIGS senses eer ee eee ee EEEE EE EEEE E EEEE E E R EEEE 36 Contents 3 Installing the server into the PACK 4 lt s csereseseseestessnnsesessanannestensnants srasanstionssadssresanestessonseansenessanseontionsiyanegenssees 36 Installing the operating SYSICIIixs cxnsiannsowsautrosteeasaivasissadeaiesiciedicadeiedu died dediasndiivasindeiadiaisatlaaiadensiiiesb ends taulaael eaten 38 Power
68. eight ___ B 7B em AA Deph SF SS dS BB em TBAT l 54 in 20 4 kg 47 2 lb Power supply specifications Depending on installed options the server is configured with one of the following power supplies e HP 460 W CS HE Power Supply 92 specifications on page 112 e HP 460 W CS Platinum Power Supply 94 specifications on page 112 e HP 750 W CS HE Power Supply 92 specifications on page 1 2 e HP 750 W CS Platinum Power Supply 94 specifications on page 113 e HP 750 W 48V CS Power Supply specifications on page 1 13 e HP 1200 W CS HE Power Supply 90 specifications on page 1 14 Specifications 111 HP 460 W CS HE Power Supply 92 specifications Specification Value ico e Rated input voltage 100 to 120 VAC 200 to 240 VAC Rated input frequency 50 Hz to 60 Hz Rated input current 5 5 A at 100 VAC 2 6 A at 200 VAC Rated input power 526 W at 100V AC input 505 W at 200V AC input BTUs per hour 1794 at 100V AC input 1725 at 200V AC input Rated steady state power 460 W at 1 OOV to 20V AC input 460 W at 200V to 240V AC input Maximum peak power 460 W at 100V to 120V AC input 460 W at 200V to 240V AC input O HP 460 W CS Platinum Power Supply 94 specifications Input requirements Rated input voltage 100 to 120 VAC 200 to 240 VAC Rated input frequency 50 Hz to 60 Hz Rated input current 5 2 A at 100 VAC 2 5 A at 200 VAC Rated input power 517 W at 100V AC input 496 W a
69. eiros de servi o da HP concluir que o reparo pode ser efetuado pelo uso de uma pe a CSR a pe a de reposi o ser enviada diretamente ao cliente Existem duas categorias de pe as CSR Obrigat ria Pe as cujo reparo feito pelo cliente obrigat rio Se desejar que a HP substitua essas pe as ser o cobradas as despesas de transporte e m o de obra do servi o Technical support 119 Opcional Pe as cujo reparo feito pelo cliente opcional Essas pe as tamb m s o projetadas para o reparo feito pelo cliente No entanto se desejar que a HP as substitua pode haver ou n o a cobran a de taxa adicional dependendo do tipo de servi o de garantia destinado ao produto OBSERVA O Algumas pe as da HP n o s o projetadas para o reparo feito pelo cliente A fim de cumprir a garantia do cliente a HP exige que um t cnico autorizado substitua a pe a Essas pe as est o identificadas com a marca No N o no cat logo de pe as ilustrado Conforme a disponibilidade e o local geogr fico as pe as CSR ser o enviadas no primeiro dia til ap s o pedido Onde as condi es geogr ficas permitirem a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional Se precisar de aux lio entre em contato com o Centro de suporte t cnico da HP para que um t cnico o ajude por telefone A HP especifica nos materiais fornecidos com a pe a CSR de reposi o se a pe a com defeito deve ser devolvida HP Nos
70. en o O One or more DIMMs have failed DIMM amber fe ee DIMM in DIMM in slot X is in a pre ailure condition Xisina DIMM in slot X is in a pre ailure condition failure condition Over temp amber Amber CE The Health Driver has detected a cautionary temperature level Over temp amber Amber The server has detected a hardware critical temperature level PCI riser amber parerent s a The PCI riser cage is not seated properly F n Fan ambe sd One fan has failed or has been removed Fan ace 4 Green Two or more fans have failed or been removed Power a amber Amber One or more of the following conditions may exist Only one power supply is installed and that power supply is in standby Power supply fault System board fault Power supply amber Amber Green One or more of the following conditions may exist Redundant power supply is installed and only one power supply is functional AC power cord is not plugged into redundant power supply Redundant power supply fault Power supply mismatch at POST or power supply mismatch through hot plug addition Powercap ol EO o e f rows cop reen Green Foner ovali iy IMPORTANT If more than one DIMM slot LED is illuminated further troubleshooting is required Test each bank of DIMMs by removing all other DIMMs Isolate the failed DIMM by replacing each DIMM in a bank with a known working DIMM Component identification 11 Rear panel components
71. er NOTE If the boot drive is not empty or has been written to in the past ORCA does not automatically configure the array You must run ORCA to configure the array settings Software and configuration utilities 95 NOTE The server may not support all the following examples Drives installed RAID level 1 1 RAID O 2 RAID 1 3 4 5 or 6 3 4 5 or 6 RAID 5 More than 6 9 Nome To change any ORCA default settings and override the auto configuration process press the F8 key when prompted For more information on RBSU see the HP ROM Based Setup Utility User Guide on the Documentation CD or the HP website http www hp com support rbsu Boot options Near the end of the boot process the boot options screen is displayed This screen is visible for several seconds before the system attempts to boot from a supported boot device During this time you can do the following e Access RBSU by pressing the F9 key e Access Intelligent Provisioning Maintenance Menu by pressing the F10 key e Access the boot menu by pressing the F11 key Force a PXE Network boot by pressing the F12 key Configuring AMP modes Not all ProLiant servers support all AMP modes RBSU provides menu options only for the modes supported by the server Advanced memory protection within RBSU enables the following advanced memory modes Advanced ECC Mode Provides memory protection beyond Standard ECC All single bit failures and some multi
72. eral Communications Commission notice Part 15 of the Federal Communications Commission FCC Rules and Regulations has established Radio Frequency RF emission limits to provide an interference free radio frequency spectrum Many electronic devices including computers generate RF energy incidental to their intended function and are therefore covered by these rules These rules place computers and related peripheral devices into two classes A and B depending upon their intended installation Class A devices are those that may reasonably be expected to be installed in a business or commercial environment Class B devices are those that may reasonably be expected to be installed in a residential environment for example personal computers The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user FCC rating label The FCC rating label on the device shows the classification A or B of the equipment Class B devices have an FCC logo or ID on the label Class A devices do not have an FCC logo or ID on the label After you determine the class of the device refer to the corresponding statement FCC Notice Class A Equipment This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interfere
73. f the DC system The DC system should be earthed elsewhere e The DC supply source is to be located within the same premises as the equipment e Switching or disconnecting devices should not be in the earthed circuit conductor between the DC source and the point of connection of the earthing electrode conductor To connect a DC power cable to a DC power source 1 Cut the DC power cord ends no shorter than 150 cm 59 06 in 2 If the power source requires ring tongues use a crimping tool fo install the ring tongues on the power cord wires We IMPORTANT The ring tongues must be UL approved and accommodate 12 gauge wires Wa IMPORTANT The minimum nominal thread diameter of a pillar or stud type terminal must be 3 5 mm 0 138 in the diameter of a screw type terminal must be 4 0 mm 0 157 in 3 Stack each same colored pair of wires and then attach them to the same power source The power cord consists of three wires black red and green For more information see the HP 750W Common Slot 48V DC Input HotPlug Power Supply Installation Instructions Rack warnings Setup 35 Z WARNING To reduce the risk of personal injury or damage to the equipment be sure that e The leveling jacks are extended to the floor e The full weight of the rack rests on the leveling jacks e The stabilizing feet are attached to the rack if it is a single rack installation e The racks are coupled together in multiple rack installations e Only one com
74. full length expansion board the air baffle can be installed last 20 Connect the other end of the SAS signal cables to the SAS controller board and to the system board Then install the PCI riser cage SAS cables can be connected to the PCI riser cage and the system board before or after the PCI riser cage is installed For ease of accessing connectors HP recommends connecting the cables before the PCI riser cage is installed Hardware options installation 77 Completed SAS cabling 21 22 23 24 25 26 Make sure any installed full length expansion boards are seated in the retainer clip on the air baffle Install the access panel on page 23 Install the server into the rack Connect each power cord to the server Connect each power cord to the power source Power up the server on page 21 2U rack bezel option The 2U rack bezel helps prevent any unauthorized physical access to the server in the rack configuration To access the hard drive cage you must unlock and open the 2U rack bezel To unlock the 2U rack bezel use the key provided with the kit Hardware options installation 78 Install the 2U rack bezel into the chassis and then lock the 2U rack bezel with the key HP Trusted Platform Module option Use these instructions to install and enable a TPM on a supported server This procedure includes three sections 1 2 3 Installing the Trusted Platform Module board Retaining the recove
75. he full length expansion board Z CAUTION To prevent damage to the server or expansion boards power down the server and remove all AC power cords before removing or installing the PCI riser cage To remove the component 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Operations 26 5 Release the full length expansion board retainer and then remove the PCI riser cage 6 Remove the full length expansion board To replace the component reverse the removal procedure Remove the PCI riser cage Z CAUTION To prevent damage to the server or expansion boards power down the server and remove all AC power cords before removing or installing the PCI riser cage 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 4 Remove the access panel on page 22 Operations 27 5 Release the full length expansion board retainer and then remove the PCI riser cage 6 Remove the full length expansion board Install the PCI riser cage Z WARNING To reduce the risk of personal injury electric shock or damage to the equipment remove the power cord to remove power from the server
76. ies deployment 93 97 98 V ventilation 35 Version Control 104 video connector 7 W warnings 38 website HP 122 Index 128
77. il AC power is removed 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Hardware options installation 62 Remove any attached network cables Extend the server from the rack on page 21 Remove the access panel on page 22 Loosen the thumbscrew aS 2 amp amp Remove the existing FlexLOM 8 Install the component a Firmly seat the FlexLOM in the slot b Tighten the thumbscrew 9 Install the access panel on page 23 10 Slide the server into the rack 11 Connect the LAN segment cables 12 Connect each power cord to the server Hardware options installation 63 13 Connect each power cord to the power source 14 Power up the server on page 21 Expansion board options The server supports PCI Express expansion boards The server ships with PCle riser boards and expansion slots PCle expansion boards are supported with optional riser boards Removing the expansion slot blanks Z CAUTION To prevent damage to the server or expansion boards power down the server and remove all AC power cords before removing or installing the PCI riser cage Z CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers or blanks installed If the server supports hot plug components minimize the amount of time the access panel is open To remove th
78. imum clearance of 76 2 cm 30 in behind the rack e Leave a minimum clearance of 121 9 cm 48 in from the back of the rack to the back of another rack or row of racks HP servers draw in cool air through the front door and expel warm air through the rear door Therefore the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet Z CAUTION To prevent improper cooling and damage to the equipment do not block the ventilation openings When vertical space in the rack is not filled by a server or rack component the gaps between the components cause changes in airflow through the rack and across the servers Cover all gaps with blanking panels to maintain proper airflow Z CAUTION Always use blanking panels to fill empty vertical spaces in the rack This arrangement ensures proper airflow Using a rack without blanking panels results in improper cooling that can lead to thermal damage The 9000 and 10000 Series Racks provide proper server cooling from flow through perforations in the front and rear doors that provide 64 percent open area for ventilation Z CAUTION When using a Compaq branded 7000 series rack install the high airflow rack door insert PN 327281 B21 for 42U rack PN 157847 B21 for 22U rack to provide proper front to back airflow and cooling Z CAUTION Ifa third party rac
79. ing on and selecting boot options lt cicesicsacsennseaieancssassansseasasssunaannaesensusssastesancsabnsendssacsqacganaueasnenassnans 38 R gistering these a ee EEE ee ee R 39 Hardware ophions metalai oNrssemmsisii e aa 40 Jakie Elele E E 40 Processor and fan option ccccccsscccsssceeseeceseceesseeeesceeeeeeeesseeeeseeeesseeessseeesseeeceseeecssesesseeeesseeecssesesseesenseeensaes 40 OANE EE EE ATE E E E E E EE E E E E E E E E T 47 PF SPRATT STO Y crcr eee EE GSN EERE 48 Memory subsystem architecture ccccccccccsssccessecessscecsseceessecesseeecsseeesseeecsseeecsseeesseeccsseeessseseseesenseeensaes 48 Single dual and quad rank DIMMs 3d a a a 48 DIMM identification siccin rer E A eee een R 49 Mem rycontiguratiohS senasa e e e eee 50 General DIMM slot population guidelines s nssnseiseississeeseessississetsersrisrtsstrstrsisrissersersrisressersersreses 51 eile DIMM orere E eee ees 52 Hot plug hard drive options iccictouindeuiumea eu eee eee 53 Installing a hot plug SAS or SATA hard drive cccescescesseeseseeeseeeneeeneecnseeeeeeneeenseeseeeneeseaeeenteeneeeaees 53 Removing a hot plug SAS or SATA hard drive ccecceesceesseeeseeeseeeeecneeceseceeeeneeenseeeeeeneeenaeeeeeeneeennees 54 Controller Options cccccccssccssscecesecessseecsseeeceeeeseeeeesseeecsseeeseeecsseeessseeeeseeecseeecseeesseescssecesseeeeseeecsseeeeesseees 55 Installing the flash backed write cache module ceceesceesseeeseeeeeeeeeeee
80. ivet on an installed TPM administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data 8 Install the TPM board Press down on the connector to seat the board System board components on page 14 Hardware options installation 80 9 10 it 12 13 14 15 16 Install the TPM security rivet by pressing the rivet firmly into the system board Install the air baffle Install the PCI riser cage on page 28 Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 Connect each power cord to the server Connect each power cord to the power source Power up the server on page 21 Retaining the recovery key password The recovery key password is generated during Bitlocker setup and can be saved and printed after Bitlocker is enabled When using BitLocker always retain the recovery key password The recovery key password is required to enter Recovery Mode after BitLocker detects a possible compromise of system integrity To help ensure maximum security observe the following guidelines when retaining the recovery key password Always store the recovery key password in multiple locations Always store copies of the recovery key password away from the server Do not save the recovery key password on the encrypted hard drive Enabling the Trusted Platform Module a Ss
81. k is used observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment e Front and rear doors lIf the 42U rack includes closing front and rear doors you must allow 5 350 sq cm 830 sq in of holes evenly distributed from top to bottom to permit adequate airflow equivalent to the required 64 percent open area for ventilation e Side The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm 2 75 in iy IMPORTANT The HP ProLiant DL380p Gen8 Server cable management arm is not supported on Compaq branded 7000 series racks Temperature requirements To ensure continued safe and reliable equipment operation install or position the system in a well ventilated climate controlled environment The maximum recommended ambient operating temperature TMRA for most server products is 35 C 95 F The temperature in the room where the rack is located must not exceed 35 C 95 F Setup 33 Z CAUTION To reduce the risk of damage to the equipment when installing third party options e Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the maximum allowable limits e Do not exceed the manufacturer s TMRA Power requirements Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equi
82. lated channel must have a spare rank o A single dual rank DIMM is not a valid configuration o LRDIMMs are treated as dual rank DIMMs Lockstep Memory population guidelines For Lockstep memory mode configurations observe the following guidelines Observe the general DIMM slot population guidelines on page 51 DIMM configuration on all channels of a processor must be identical In multi processor configurations each processor must have a valid Lockstep Memory configuration In multi processor configurations each processor may have a different valid Lockstep Memory configuration Population order For memory configurations with a single processor or multiple processors populate the DIMM slots in the following order LRDIMM Sequentially in alphabetical order A through L RDIMM Sequentially in alphabetical order A through L UDIMM A through H sequentially in alphabetical order Do not populate DIMM slots through L After installing the DIMMs use RBSU to configure Advanced ECC online spare or lockstep memory support Installing a DIMM The server supports up to 24 DIMMs To install a DIMM 1 2 nue w Power down the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Remove the air baffle on page 30 Open the DIMM slot latches Ha
83. less all PCI slots have either an expansion slot cover or an expansion board installed We IMPORTANT The secondary PCI riser cage option requires both processors To install the component 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Remove the PCI riser blank Hardware options installation 67 6 Remove the blank from the optional secondary PCI riser cage T Hardware options installation 68 8 Install the optional secondary PCI riser cage If not already installed install the secondary processor Processor and fan option on page 40 Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 Connect each power cord to the server Connect each power cord to the power source Power up the server on page 21 Hard drive cage option A SAS expander card or an additional SAS controller option is required to support the hard drive cage option To install the component 1 2 Power down the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Hardware options in
84. ling do not operate the server without the access panel baffles expansion slot covers or blanks installed If the server supports hot plug components minimize the amount of time the access panel is open 1 Determine the status of the hard drive from the hot plug SAS hard drive LED combinations Drive LED definitions on page 17 2 Back up all server data on the drive Hardware options installation 54 3 Remove the drive Controller options The server ships with an embedded Smart Array P420i controller For more information about the controller and its features see the HP Smart Array Controllers for HP Proliant Servers User Guide on the HP website http bizsupport2 austin hp com bc docs support SupportManual c01608507 c01608507 pdf To configure arrays see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website http bizsupport austin hp com bc docs support SupportManual c007 29544 c007 29544 pdf Upgrade options exist for the integrated array controller For a list of supported options see the QuickSpecs on the HP website http www hp com support The server supports FBWC FBWC consists of a cache module and a capacitor pack The DDR cache module buffers and stores data being written by the controller When the system is powered on the capacitor pack charges fully in about 5 minutes In the event of a system power failure a fully charged capacitor pack provides power for up to 8
85. n ccccccccccssssccssscecsseccesseeesseeeesseeeeseeeesseeeesseeesseeeesseeeceseeeessesesseeeessecesssesesseeeeseeessseeeeeas 78 HP Trusted Platform Module option ccccccccssscessscceseeessececssececeeccsseceesseeesseeseeseeeesseeeeseeeesseeessseeesseesessaeensaes 79 Installing the Trusted Platform Module board cccccesscessseeeseeeseeeneeeneeceaeeneeeeeenseeeeesneeenseeereeneeenaees 80 Retaining the recovery key password cccccccsseeseeeeseeeseeeeeeneeenseeeseeeeeceaeceeeeneeeeseeeeecneeenseeeeeeneeeneees 81 Enabling the Trusted Platform Module ccscceesseeeeeeeeeeeesereenseceseeceecnaeeeseeeneeenseeeeeseeseseeeteeeneeenaees 8 el E PA E A ES AR AAEE E A A E E E EE AETAT 83 SAS harddrivecabliNg aarne a E E ter E E at serer em 83 Optical drive MoI Ia asses ssn srctussoosisesicnssausiesqusutuvuncouhesiadiukasnndguaacuauctasesncubaiuas dei ERER REAR EA 84 TEI 4 Cia yaaa naa E RA INFRA Ua ead yea ANDAR ANA URI Ny Rann Goeateaeetade 85 Chipset SATA cable Option ccccccsccccssececsseccesseecssececsecesseeeeseeeseseceseeeesseeecsececsseeeeseeecsseeesseeeseeseneeessaeees 86 150W PCle power cable Option ccccccsscccssscecsseceesseecsececsseecseeecssececseeesseeeesseeesssesesseeecssesessseeesteeecnseeeess 89 Solware and SONATE vii Neg sass cass trsiarisersvard tasecetsnstners crmieranetnatanmncmiuuaseneserengnsactenenucniae 90 Serner Modes aes rera E usta tessa Sasias esses tonsk E EE EIA 90 Server QuickSpecs c
86. nal injury e Do not attempt to recharge the battery e Do not expose the battery to temperatures higher than 60 C 140 F e Do not disassemble crush puncture short external contacts or dispose of in fire or water e Replace only with the spare designated for this product To remove the component 1 Power down the server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Remove the PCI riser cage on page 27 Locate the battery System board components on page 14 NOM Bp w amp Remove the battery To replace the component reverse the removal procedure For more information about battery replacement or proper disposal contact an authorized reseller or an authorized service provider Battery replacement 103 Regulatory compliance notices Regulatory compliance identification numbers For the purpose of regulatory compliance certifications and identification this product has been assigned a unique regulatory model number The regulatory model number can be found on the product nameplate label along with all required approval markings and information When requesting compliance information for this product always refer to this regulatory model number The regulatory model number is not the marketing name or model number of the product Fed
87. nce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at personal expense FCC Notice Class B Equipment This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to Regulatory compliance notices 104 radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit that is different from tha
88. nformation Technology Equipment e Connect the equipment to a reliably grounded SELV source An SELV source is a secondary circuit that is designed so normal and single fault conditions do not cause the voltages to exceed a safe level 60 V direct current e The branch circuit overcurrent protection must be rated 20A WARNING When installing a DC power supply the ground wire must be connected before the positive or negative leads WARNING Remove power from the power supply before performing any installation steps or maintenance on the power supply CAUTION The server equipment connects the earthed conductor of the DC supply circuit to the earthing conductor at the equipment For more information see the HP 750W Common Slot 48V DC Input Hot Plug Power Supply Kit Installation Instructions Z CAUTION If the DC connection between the earthed conductor of the DC supply circuit and the earthing conductor at the server equipment the following conditions must be met e This equipment must be connected directly to the DC supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is connected e This equipment should be located in the same immediate area such as adjacent cabinets as any other equipment that has a connection between the earthed conductor of the same DC supply circuit and the earthing conductor and also the point of earthing o
89. ng the current logical drive configuration e Deleting a logical drive configuration e Setting the controller to be the boot controller e Selecting the boot volume If you do not use the utility ORCA will default to the standard configuration For more information regarding the default configurations that ORCA uses see the HP ROM Based Setup Utility User Guide on the Documentation CD or the HP website http www hp com support rbsu For more information about the controller and its features see the HP Smart Array Controllers for HP ProLiant Servers User Guide on the HP website http bizsupport2 austin hp com bc docs support SupportManual c01608507 c01608507 pdf To configure arrays see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the HP website http bizsupport austin hp com bc docs support SupportManual c00729544 c00729544 pdf ROMPag utility The ROMPag utility enables you to upgrade the system firmware BIOS To upgrade the firmware insert a ROMPag USB Key into an available USB port and boot the system In addition to ROMPaq Online Flash Components for Windows and Linux operating systems are available for updating the system firmware The ROMPag utility checks the system and provides a choice if more than one exists of available firmware revisions Software and configuration utilities 98 For more information see the Download drivers and software page for the server To access the server sp
90. nsiontion 9 SEEE aTe LaLa DIET o A in DE 10 Systems Insight Display LED combinations Sci sesiseves cueteusn cekcawsecvatveselecvatscsseceslecndecusgcuedenseendess desdecedeavducdevecensucinyn 1 Coll oto a 1B cctol 111 910 lt 1 eer ee eae rt re re 12 Rear panel LEDs and buttons ccccccccccssscessseecssececseeesececsececseeecsseeecseceseeeseseeecseeessseecssesecsseeeeeesensaeessaes 12 Non hot plug PCI riser board slot definitions g asssasssivamsarnnnnsnncntnensdensanuniusncntaiaiasentsahhsnedesiinsnhastaessbesiapanteivsens 13 System board components cccccessceesseecesececesececeseeceececeecessseeeseeeceseeeseeeceseeecseceseeeeeeeeceseeesssesesteeeesseeenss 14 System maintenance switch c cccccccecscccssececsseeceececssececeeceseeecseeesseeecsseeecseeeeseeecsseeecseceseesenseeensaes 15 NMI functionality cccccccccccscccsseccsssecessececsececsseceseeecsseeecsseeeseeecssecesseeesseeesseeeceseeecsseseseeecsseeensaes 16 DIMM sl t IGGanOns c c 2 ctaieiee ue atau au ue GuE eeu aaus 16 SAS and SATA device MUNDEE uuu 17 Drive LED defii ons eere e E E E E 17 RAEE oE i D RE E AAE E A E AE EE E 18 FBWC module LEDs P222 P420 PART uncon R ERSE 19 Hot plug faisses eE ee ee 19 CFE e E U AIEI ET AE A OENE ETT 21 Power up the S rver cccccsccccssecessseeeseeecsseceeeeecsseeecsseeeseeecsseeecsecesseeeesseeecseeecseesesseeecseeesseeeesseeeceseeecesaeeenas 21 Power down the server s cssissssssssssssseebsssnsvassnsosnsssnssdbaesssesb
91. nstallation so that the heaviest item is on the bottom of the rack Install the heaviest item first and continue to populate the rack from the bottom to the top 1 Install the server and cable management arm into the rack For more information see the installation instructions that ship with the 2U Quick Deploy Rail System 2 Connect peripheral devices to the server For information on identifying connectors see Rear panel components on page 2 Setup 36 Z WARNING To reduce the risk of electric shock fire or damage to the equipment do not plug telephone or telecommunications connectors into RJ 45 connectors 3 Connect the power cord to the rear of the server 4 Install the power cord anchors 5 Secure the cables to the cable management arm iy IMPORTANT When using cable management arm components be sure to leave enough slack in each of the cables to prevent damage to the cables when the server is extended from the rack 5 CN ATCA EO A ghia Ny Lele eln t 9 N N cle 6 Connect the power cord to the AC power source Setup 37 A WARNING To reduce the risk of electric shock or damage to the equipment e Do not disable the power cord grounding plug The grounding plug is an important safety feature e Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times e Unplug the power cord from the power supply to disconnect po
92. o not try to open the module enclosure There are no user serviceable components inside e Do not operate controls make adjustments or perform procedures to the laser device other than those specified herein e Allow only HP Authorized Service technicians to repair the unit The Center for Devices and Radiological Health CDRH of the U S Food and Drug Administration implemented regulations for laser products on August 2 1976 These regulations apply to laser products manufactured from August 1 1976 Compliance is mandatory for products marketed in the United States Battery replacement notice Z WARNING The computer contains an internal lithium manganese dioxide a vanadium pentoxide or an alkaline battery pack A risk of fire and burns exists if the battery pack is not properly handled To reduce the risk of personal injury e Do not attempt to recharge the battery e Do not expose the battery to temperatures higher than 60 C 140 F e Do not disassemble crush puncture short external contacts or dispose of in fire or water Batteries battery packs and accumulators should not be disposed of together with the general household waste To forward them to recycling or proper disposal use the public collection system or return them to HP an authorized HP Partner or their agents Regulatory compliance notices 108 For more information about battery replacement or proper disposal contact an authorized reseller or an authoriz
93. oftware maintenance on ProLiant servers and server blades To view the guide select a language English http www hp com support ProLiant_TSG_v1_en French http www hp com support ProLiant_TSG_v1_fr Spanish http www hp com support ProLiant_TSG_v1_sp German http www hp com support ProLiant_TSG_v1_gr Japanese http www hp com support ProLiant_TSG_v1_jp Simplified Chinese http www hp com support ProLiant_TSG_v1_sc The HP Proliant Gen8 Troubleshooting Guide Volume Il Error Messages provides a list of error messages and information to assist with interpreting and resolving error messages on ProLiant servers and server blades To view the guide select a language English http www hp com support ProLiant_EMG_v1_en French http www hp com support ProLiant_EMG_v1_fr Spanish http www hp com support ProLiant_EMG_v1_sp German http www hp com support ProLiant_EMG_v1_gr Japanese http www hp com support ProLiant_EMG_v1_jp Simplified Chinese http www hp com support ProLiant_EMG_v1_sc Troubleshooting 102 Battery replacement If the server no longer automatically displays the correct date and time you may need to replace the battery that provides power to the real time clock Z WARNING The computer contains an internal lithium manganese dioxide a vanadium pentoxide or an alkaline battery pack A risk of fire and burns exists if the battery pack is not properly handled To reduce the risk of perso
94. om go selfrepair Customer Self Repair Veel onderdelen in HP producten zijn door de klant zelf te repareren waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is Deze onderdelen worden CSR onderdelen Customer Self Repair genoemd Als HP of een HP Service Partner bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR onderdeel verzendt HP dat onderdeel rechtstreeks naar u zodat u het defecte onderdeel daarmee kunt vervangen Er zijn twee categorie n CSR onderdelen Verplicht Onderdelen waarvoor reparatie door de klant verplicht is Als u HP verzoekt deze onderdelen voor u te vervangen worden u voor deze service reiskosten en arbeidsloon in rekening gebracht Optioneel Onderdelen waarvoor reparatie door de klant optioneel is Ook deze onderdelen zijn ontworpen voor reparatie door de klant Als u echter HP verzoekt deze onderdelen voor u te vervangen kunnen daarvoor extra kosten in rekening worden gebracht afhankelijk van het type garantieservice voor het product OPMERKING Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen Deze onderdelen worden in de geillustreerde onderdelencatalogus aangemerkt met Nee Afhankelijk van de leverbaarheid en de locatie worden CSR onderdelen verzonden voor levering op
95. ool before touching them Z CAUTION For proper cooling do not operate the server without the access panel baffles expansion slot covers or blanks installed If the server supports hot plug components minimize the amount of time the access panel is open Operations 22 To remove the component 1 Power down the server if performing a non hot plug installation or maintenance procedure Power down the server on page 21 Extend the server from the rack on page 21 Use the T 15 Torx screwdriver attached to the rear of the server to loosen the security screw on the hood latch Lift up on the hood latch handle and then remove the access panel Install the access panel 1 Place the access panel on top of the server with the hood latch open Allow the panel to extend past the rear of the server approximately 1 25 cm 0 5 in Push down on the hood latch The access panel slides to a closed position Use the T 15 Torx screwdriver attached to the rear of the server to tighten the security screw on the hood latch Access the product rear panel Opening the cable management arm To access the server rear panel LE Release the cable management arm ss o 8 amp Operations 23 2 Open the cable management arm Note that the cable management arm can be right mounted or left mounted Remove the hot plug fan cage To remove the component 1 Power down the
96. or System maintenance switch Off HP iLO security is enabled On HP iLO security is disabled Off System configuration can be changed On System configuration is locked SA Off Reserved Off Off Power on password is enabled On Power on password is disabled S Off Off No function On ROM reads system configuration as invalid zo F ees oo s E ee o OOOO C a e so F Reseed SSCS moo E eeo oO o E Reserved ooo To access redundant ROM set S1 S5 and S6 to on Component identification 15 When the system maintenance switch position 6 is set to the On position the system is prepared to erase all system configuration settings from both CMOS and NVRAM Z CAUTION Clearing CMOS and or NVRAM deletes configuration information Be sure to properly configure the server or data loss could occur NMI functionality An NMI crash dump enables administrators to create crash dump files when a system is hung and not responding to traditional debug mechanisms Crash dump log analysis is an essential part of diagnosing reliability problems such as hangs in operating systems device drivers and applications Many crashes freeze a system and the only available action for administrators is to cycle the system power Resetting the system erases any information that could support problem analysis but the NMI feature preserves that information by performing a memory dump before a hard reset To force the O
97. other option drivers ROM images and value add software can be downloaded as part of an SPP If you are installing drivers from SPP be sure that you are using the latest SPP version that your server supports To verify that your server is using the latest supported version and for more information about SPP see the HP website http www hp com go spp download To directly locate the OS drivers for a particular server enter the following web address into the browser http www hp com support lt servername gt In place of lt servername gt enter the server name For example http www hp com support dl360g6 Software and firmware Software and firmware should be updated before using the server for the first time unless any installed software or components require an older version For system software and firmware updates download the SPP HP Service Pack for ProLiant on page 94 from the HP website http www hp com go spp Version control The VCRM and VCA are web enabled Insight Management Agents tools that HP SIM uses to schedule software update tasks to the entire enterprise e VCRM manages the repository for SPP Administrators can view the SPP contents or configure VCRM to automatically update the repository with internet downloads of the latest software and firmware from HP e VCA compares installed software versions on the node with updates available in the VCRM managed repository Administrators configure VCA to
98. own the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Release the full length expansion board retainer and then remove the PCI riser cage Remove the expansion slot cover Removing the expansion slot blanks on page 64 Install the expansion board Connect any required internal or external cables to the expansion board See the documentation that ships with the expansion board Install the PCI riser cage on page 28 Secure the full length expansion board retainer on page 29 if any full length expansion boards are installed Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 Connect each power cord to the server Connect each power cord to the power source Hardware options installation 66 15 Power up the server on page 21 Secondary PCI riser cage option Z WARNING To reduce the risk of personal injury electric shock or damage to the equipment remove the power cord to remove power from the server The front panel Power On Standby button does not completely shut off system power Portions of the power supply and some internal circuitry remain active until AC power is removed Z CAUTION To prevent improper cooling and thermal damage do not operate the server un
99. pment by licensed electricians This equipment is designed to operate in installations covered by NFPA 70 1999 Edition National Electric Code and NFPA 75 1992 code for Protection of Electronic Computer Data Processing Equipment For electrical power ratings on options refer to the product rating label or the user documentation supplied with that option A WARNING To reduce the risk of personal injury fire or damage to the equipment do not overload the AC supply branch circuit that provides power to the rack Consult the electrical authority having jurisdiction over wiring and installation requirements of your facility Z CAUTION Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply UPS This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure When installing more than one server you may need to use additional power distribution devices to safely provide power to all devices Observe the following guidelines e Balance the server power load between available AC supply branch circuits e Do not allow the overall system AC current load to exceed 80 percent of the branch circuit AC current rating e Do not use common power outlet strips for this equipment e Provide a separate electrical circuit for the server Electrical grounding requirements The server must be grounded prope
100. ponent is extended at a time A rack may become unstable if more than one component is extended for any reason Z WARNING To reduce the risk of personal injury or equipment damage when unloading a rack e Atleast two people are needed to safely unload the rack from the pallet An empty 42U rack can weigh as much as 115 kg 253 b can stand more than 2 1 m 7 ft tall and might become unstable when being moved on its casters e Never stand in front of the rack when it is rolling down the ramp from the pallet Always handle the rack from both sides Identifying the contents of the server shipping carton Unpack the server shipping carton and locate the materials and documentation necessary for installing the server All the rack mounting hardware necessary for installing the server into the rack is included with the rack or the server The contents of the server shipping carton include e Server e Power cord e Hardware documentation Documentation CD and software products e Rack mounting hardware In addition to the supplied items you may need e Operating system or application software e Hardware options Installing hardware options Install any hardware options before initializing the server For options installation information refer to the option documentation For server specific information refer to Hardware options installation on page 40 Installing the server into the rack Z CAUTION Always plan the rack i
101. r green the drive will fail Flashing amber The drive is not configured and predicts the drive will fail Pf Solid amber The drive has failed Off The drive is not configured by a RAID controller PCI riser cage LED A CAUTION To prevent damage to the server or expansion boards power down the server and remove all AC power cords before removing or installing the PCI riser cage Missing Riser cage is not installed or power might not be connected Component identification 18 FBWC module LEDs P222 P420 P421 The FBWC module has three single color LEDs one amber and two green The LEDs are duplicated on the reverse side of the cache module to facilitate status viewing 1 Amber _ 2 Green 3 Green Interpretation The cache module is not powered Off Flashing 0 5 Hz Flashing 0 5 Hz The cache microcontroller is executing from within its boot loader and receiving new flash code from the host controller Off Flashing 1 Hz Flashing 1 Hz The cache module is powering up and the capacitor pack is charging Off Off Flashing 1 Hz The cache module is idle and the capacitor pack is charging Off Off The cache module is idle and the capacitor pack is charged Off The cache module is idle the capacitor pack is charged and the cache contains data that has not yet been written to the drives Flashing 1 Hz A backup is in progress Ons The current backup is complete with no errors The current backup
102. ranean eae E 96 Configuring AMP TREES cscs ssccscocssnslsancscaneancsadeanstsedon then eqaneied widened utaciates wintnieiasetasstesetaiasedased aden sasennes 96 Re entering the server serial number and product ID ccessceeseeeseeenseceseeeeeeneeenaeeeseeeneeseaeeeeeeneeeenees 96 Utilities and features a ss cececgnassstisn astsauteanscnssiensuateetseculdsuagrangionsdecnicasbecgnanahaces qnpinaueantherednadbuageanctecaaneabueusencdiice 97 Array Configuration Utility coccensvarsrensceveconiegracinaronseanneaten ream as ecraiverntnearteny ana ara 97 Option ROM Configuration for Atay s aiccedscassredinontynntenstenctenetvcetceddecssnndtnwitucdiuaddeaddvediucateassuantentenabints 98 ROMPE Util eee rr ee 98 AUTO MALI EZ Server Recova y 0 55 0 chisainsasshasiecsiesnaceise cinaceusecitdecndcensesnteensesntecnssnntsrkssnntsrnssnntsresenndnensnerdverertiies 99 WS B SUDDOM cicccese enentcncesestsssesnsvsvsveasesvstsnsvsvsvecsvsvsvscsvsvsteastsvstsasvsvstsasesvsvsasesvsvecsesvstsastsvstscsesesereste sess 99 Redundant ROM Support ccccccesscccssecessececsececssecceeeecssececseeesseeecssececseeessseeesseeecsseeecsseseseeecssesensaes 99 Keeping the system FY OUP ay sta phetacns ar aus baba np une ane cnn ONS Reade 100 MDI VST Soe tee ca caatstit secs vaet E ay gant ensue aed E E pockverteazsueubieuerteeusaeutys ever aeve a 100 Sotware and EE aanere aaa a E E E E E E E E E 100 Version confrol seese oa aere ESA E EAE R REE AER EE IRERE RS 100
103. rank DIMM has one set of memory chips that is accessed while writing to or reading from the memory A dual rank DIMM is similar to having two single rank DIMMs on the same module with only one rank accessible at a time A quad rank DIMM is effectively two dual rank DIMMs on the same module Only one rank is accessible at a time The server memory control subsystem selects the proper rank within the DIMM when writing to or reading from the DIMM Hardware options installation 48 Dual and quad rank DIMMs provide the greatest capacity with the existing memory technology For example if current DRAM technology supports 8 GB single rank DIMMs a dual rank DIMM would be 16 GB and a quad rank DIMM would be 32 GB LRDIMMs are labeled as quad rank DIMMs however they function more like dual rank DIMMs There are four ranks of DRAM on the DIMM but the LRDIMM buffer creates an abstraction that allows the DIMM to appear as a dual rank DIMM to the system The LRDIMM buffer also isolates the electrical loading of the DRAM from the system to allow for faster operation These two changes allow the system to support up to three LRDIMMs per memory channel providing for up to 50 greater memory capacity and higher memory operating speed compared to quad rank RDIMMs DIMM identification To determine DIMM characteristics use the label attached to the DIMM and the following illustration and table HP 8GB 2Rx8 PC3L 10600R 9 08 woman eg
104. rdware options installation 52 7 Install the DIMM Install the access panel on page 23 Install the server into the rack Installing the server into the rack on page 36 10 Connect each power cord to the server 11 Connect each power cord to the power source 12 Power up the server on page 21 Use RBSU HP ROM Based Setup Utility on page 95 to configure the memory mode For more information about LEDs and troubleshooting failed DIMMs see Systems Insight Display LED combinations on page 1 Hotplug hard drive options When adding hard drives to the server observe the following general guidelines e The system automatically sets all device numbers e If only one hard drive is used install it in the bay with the lowest device number e Drives should be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array Installing a hot plug SAS or SATA hard drive The server can support 8 SAS or SATA hard drives in a SFF or LFF configuration or 16 drives ina SFF configuration with the optional hard drive cage Hard drive cage option on page 69 To install the component Hardware options installation 53 1 Remove the drive blank 2 Prepare the drive 3 Install the drive 4 Determine the status of the drive from the drive LED definitions on page 17 Removing a hot plug SAS or SATA hard drive Z _ CAUTION For proper coo
105. rly for proper operation and safety In the United States you must install the equipment in accordance with NFPA 70 1999 Edition National Electric Code Article 250 as well as any local and regional building codes In Canada you must install the equipment in accordance with Canadian Standards Association CSA C22 1 Canadian Electrical Code In all other countries you must install the equipment in accordance with any regional or national electrical wiring codes such as the International Electrotechnical Commission IEC Code 364 parts 1 through 7 Furthermore you must be sure that all power distribution devices used in the installation such as branch wiring and receptacles are listed or certified grounding type devices Because of the high ground leakage currents associated with multiple servers connected to the same power source HP recommends the use of a PDU that is either permanently wired to the building s branch circuit or includes a nondetachable cord that is wired to an industrial style plug NEMA locking style plugs or those complying with IEC 60309 are considered suitable for this purpose Using common power outlet strips for the server is not recommended Connecting a DC power cable to a DC power source Setup 34 Z WARNING To reduce the risk of electric shock or energy hazards e This equipment must be installed by trained service personnel as defined by the NEC and IEC 60950 1 Second Edition the standard for Safety of I
106. roperly but without the performance advantage of the battery pack Hardware options installation 55 NOTE The data protection and the time limit also apply if a power outage occurs When power is restored to the system an initialization process writes the preserved data to the hard drives Installing the flash backed write cache module Z CAUTION The cache module connector does not use the industry standard DDR3 mini DIMM pinout Do not use this controller with cache modules designed for other controller models because the controller can malfunction and you can lose data Also do not transfer this cache module to an unsupported controller model because you can lose data To install the component 1 Back up all data 2 Close all applications Z CAUTION In systems that use external data storage be sure that the server is the first unit to be powered down and the last to be powered back up Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up Power down the server on page 21 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend the server from the rack on page 21 Remove the access panel on page 22 Install the cache module Hardware options installation 56 8 9 10 11 12 13 Connect the capacitor pack cable to the connector on the top of the cache module
107. ry key password on page 81 Enabling the Trusted Platform Module on page 81 Enabling the TPM requires accessing RBSU HP ROM Based Setup Utility on page 95 For more information about RBSU see the HP website hitp www hp com go ilomgmtengine docs TPM installation requires the use of drive encryption technology such as the Microsoft Windows BitLocker Drive Encryption feature For more information on BitLocker see the Microsoft website http www microsoft com Z CAUTION Always observe the guidelines in this document Failure to follow these guidelines can cause hardware damage or halt data access When installing or replacing a TPM observe the following guidelines Do not remove an installed TPM Once installed the TPM becomes a permanent part of the system board When installing or replacing hardware HP service providers cannot enable the TPM or the encryption technology For security reasons only the customer can enable these features When returning a system board for service replacement do not remove the TPM from the system board When requested HP Service provides a TPM with the spare system board Any attempt to remove an installed TPM from the system board breaks or disfigures the TPM security rivet Upon locating a broken or disfigured rivet on an installed TPM administrators should consider the system compromised and take appropriate measures to ensure the integrity of the system data When using BitLo
108. s les documents envoy s avec la pi ce de rechange CSR HP pr cise s il est n cessaire de lui retourner la pi ce d fectueuse Si c est le cas vous devez le faire dans le d lai indiqu g n ralement cing 5 jours ouvr s La pi ce et sa documentation doivent tre retourn es dans l emballage fourni Si vous ne retournez pas la pi ce d fectueuse HP se r serve le droit de vous facturer les co ts de remplacement Dans le cas d une pi ce CSR HP supporte l ensemble des frais d exp dition et de retour et d termine la soci t de courses ou le transporteur utiliser Pour plus d informations sur le programme CSR de HP contactez votre Mainteneur Agr e local Pour plus d informations sur ce programme en Am rique du Nord consultez le site Web HP http www hp com go selfrepair Technical support 116 Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilit nella sostituzione di parti difettose i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente CSR Customer Self Repair Se in fase di diagnostica HP o un centro di servizi o di assistenza HP identifica il guasto come riparabile mediante un ricambio CSR HP lo spedir direttamente al cliente per la sostituzione Vi sono due categorie di parti CSR Obbligatorie Parti che devono essere necessariamente riparate dal cliente Se il cliente ne affida la riparazione ad HP
109. server on page 21 2 Remove all power a Disconnect each power cord from the power source b Disconnect each power cord from the server Extend or remove the server from the rack Extend the server from the rack on page 21 Remove the access panel on page 22 Remove the air baffle on page 30 Operations 24 6 Remove the fan cage Z CAUTION Do not operate the server for long periods with the access panel open or removed Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage iy IMPORTANT For optimum cooling install fans in all primary fan locations For more information refer to the fan locations table Hot plug fans on page 19 To replace the component reverse the removal procedure Remove the hot plug fan To remove the component 1 Extend or remove the server from the rack Extend the server from the rack on page 21 2 Remove the access panel on page 22 Operations 25 3 Remove the fan Z CAUTION Do not operate the server for long periods with the access panel open or removed Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage Wa IMPORTANT For optimum cooling install fans in all primary fan locations For more information refer to the fan locations table Hot plug fans on page 19 To replace the component reverse the removal procedure Remove t
110. sndbsrdonssssnseasssabseabdcassbassnsvabssdsssabacdosbabasioabsoabsoabeesys 21 Extend the server from the rack ccsceeseesseeeseeeseeceeeeseceseeeeecseceaeeeseecaeeeaeeeseecnseeeaeeceeenaeenseeeneeenseeneeentees 21 Remove the access panel ccccccsssecessccessecensseceseeseeseeeeseseseseeeeeeeeseeeeeseesesaeecesesessseecesaeecsuesessaeesesaeeceueeensase 22 Install the access panel ccccccccssccsssscessseecsseeecssecessseeessececsseceseeeessececsseeeeeeeessececsseeesseeecssecessseeeseeesseeensaes 23 Access the product rear panel cccccccccsscccsseccssececsecesseeecsseeeseseeeeeeeceseeesseeeeseeecsseeecseeesseesesecesseseneeessseees 23 Opening the cable management arm ccccceeseesseeeseeenseesseeeseeceeceeeceaeeeeecnaeenseeneeenseenseesteeeneeenaeenaes 23 Remove the hot plug fan COgC scccssceesseesseeeseeeeeeneeeneeeeseeeeecnseceaeeceeceeeeaeesteesnaeenseeeneeeneeeneesteeeneeeneeeneeens 24 Remove the aalels sch Le ee ee ee ee er ea ee ee eee ee 25 Remove the full length expansion board cccccesecsseesseeeteceneeceseeeseeceecnseceaeeceecneeenseeneecnaeenseeeneeenseeneeeneeeas 26 Remove the I ts cage rosetes reac erty sane oneal one earns E Rute EE EEE tem romanian EEA 27 Install the PCI riser GAG ccsscycatecetesshesutesacea scot aden aacatns asadatasetacatanahesatnsshganbas ated asbeasonahesahysehseatecehgcshaasgastintan 28 Secure the full length expansion board retainer ccceesceeseesseceeeeseeceeeeeseeee
111. ss A equipment Regulatory compliance notices 105 This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe A respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Class B equipment This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil num rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada European Union regulatory notice Products bearing the CE marking comply with the following EU Directives e Low Voltage Directive 2006 95 EC e EMC Directive 2004 108 EC e Ecodesign Directive 2009 125 EC where applicable CE compliance of this product is valid if powered with the correct CE marked AC adapter provided by HP Compliance with these directives implies conformity to applicable harmonized European standards European Norms that are listed in the EU Declaration of Conformity issued by HP for this product or product family and available in English only either within the product documentation or at the following HP website http www hp eu certificates type the product number in the search field The compliance is indicated by one of the following conformity markings placed on the product For non telecommunications products and for EU harmonized telecommunications products s
112. stallation 69 5 Release the full length expansion board retainer and then remove the PCI riser cage Hardware options installation 70 Remove the fan cage 7 ATNA if installed a Disconnect and remove the optical drive cable 8 Hardware options installation 71 Using a T 15 Torx screwdriver remove the two optical drive retaining screws and then remove the optical drive cage 9 Install the optional hard drive cage 10 Install the hard drives and hard drive blanks 11 72 Hardware options installation 12 To access the cables remove the fan bracket on the right side of the chassis 13 Connect the cables a Connect one end of the power cable to the SAS backplane and the other end to the power connector on the system board Hardware options installation 73 b Remove the existing SAS cable from the cable guide and from the system board 14 Connect the end of each SAS signal cable to the SAS backplane and then route the SAS signal cables behind the cable guide Do not connect the other ends yet Hardware options installation 74 15 Install the fan bracket Be sure that the cables are properly routed in the channel along the fan bracket Hardware options installation 75 17 Install the SAS controller board into the PCI riser cage 18 Install the fan cage 19 Install the air baffle Hardware options installation 76 If you do not have a
113. stent way to deploy HP ProLiant server configurations e Intelligent Provisioning assists with the OS installation process by preparing the system for installing off the shelf versions of leading operating system software and automatically integrating optimized HP ProLiant server support software from SPP SPP is the installation package for operating system specitic bundles of HP ProLiant optimized drivers utilities management agents and system firmware e Intelligent Provisioning provides maintenance related tasks through Perform Maintenance features e Intelligent Provisioning provides installation help for Microsoft Windows Red Hat and SUSE Linux and VMware For specific OS support see the HP Intelligent Provisioning Release Notes For more information on Intelligent Provisioning software see the HP website http www hp com go ilo For more information about Intelligent Provisioning drivers firmware and SPP see the HP website hitp www hp com go spp download Software and configuration utilities 92 HP Insight Diagnostics HP Insight Diagnostics is a proactive server management tool available in both offline and online versions that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations troubleshoot problems and perform repair validation HP Insight Diagnostics Offline Edition performs various in depth system and component testing while the OS is not running
114. t 200V AC input Btus per hour 1764 at 100V AC input 1694 at 200V AC input Rated steady state power 460 W at 1 OOV to 20V AC input 460 W at 200V to 240V AC input Maximum peak power 460 W at 100V to 120V AC input 460 W at 200V to 240V AC input O HP 750 W CS HE Power Supply 92 specifications C a Rated input voltage 100 to 120 VAC 200 to 240 VAC Rated input frequency 0 Hz to 60 Hz Specifications 112 Rated input current 8 9 A at 100 VAC 4 3 A at 200 VAC Rated input power 857 W at 100V AC input 824 W at 200V AC input BTUs per hour 2925 at 100V AC input 2812 at 200V AC input Rated steady state power 750 W at 1 OOV to 20V AC input 750 W at 200V to 240V AC input Maximum peak power 750 W at 100V to 120V AC input 750 W at 200V to 240V AC input HP 750 W CS Platinum Power Supply 94 specifications Input requirements Rated input voltage 100 to 120 VAC 200 to 240 VAC 50 Hz to 60 Hz Rated input current 8 5 A at 100 VAC 4 1 A at 200 VAC Maximum rated input power 843 W at 100V AC input 811 W at 200V AC input Btus per hour 2878 at 100V AC input 2769 at 200V AC input Rated steady state power 750 W at 100V to 120V AC input 750 W at 200V to 240V AC input Maximum peak power 750 W at 100V to 120V AC input 750 W at 200V to 240V AC input HP 750 W 48V CS Power Supply specifications Specification Value Input requirements 100 to 240 VAC Rated Input frequenc 50 HZ to 60 HZ 9104 5 Maximum rated
115. t to which the receiver is connected Consult the dealer or an experienced radio or television technician for help Declaration of conformity for products marked with the FCC logo United States only This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation For questions regarding this product contact us by mail or telephone Hewlett Packard Company P O Box 692000 Mail Stop 530113 Houston Texas 77269 2000 1 800 HP INVENT 1 800 474 6836 For continuous quality improvement calls may be recorded or monitored For questions regarding this FCC declaration contact us by mail or telephone Hewlett Packard Company P O Box 692000 Mail Stop 510101 Houston Texas 77269 2000 1 281 514 3333 To identify this product refer to the part series or model number found on the product Modifications The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett Packard Company may void the user s authority to operate the equipment Cables Connections to this device must be made with shielded cables with metallic RFI EMI connector hoods in order to maintain compliance with FCC Rules and Regulations Canadian notice Avis Canadien Cla
116. tallation 34 38 Index 127 rack mounting hardware 38 rack resources 34 rack warnings 38 RBSU ROM Based Setup Utility 98 100 rear panel buttons 13 rear panel components 12 rear panel LEDs 13 rear panel accessing 26 redundant ROM 103 registering the server 41 regulatory compliance notices 109 112 removing a hot plug SAS hard drive 57 removing the access panel 24 required information 122 retaining the recovery key password 85 ROM redundancy 103 ROMPag utility 93 102 103 S safety considerations 38 SAS and SATA device numbers 18 scripted installation 97 serial number 100 series number 109 server features and options 42 shipping carton contents 38 space and airflow requirements 35 specifications 117 118 119 120 121 specifications environmental 117 specifications mechanical 117 specifications power 118 119 120 121 static electricity 116 support 122 supported operating systems 105 switches 17 system battery 107 system board components 15 system components 7 system maintenance switch 16 17 system power LED 9 Systems Insight Display 10 11 Systems Insight Display LEDs 10 11 T Taiwan battery recycling notice 115 technical support 105 122 123 telephone numbers 122 temperature requirements 36 TPM Trusted Platform Module 82 85 TPM connector 15 troubleshooting 106 U UID LED 17 updating the system ROM 103 USB connectors 7 USB support 103 utilities 93 101 utilit
117. th the access panel installed Description Status O Power cap Off System is in standby or no cap is set Solid green Power cap applied NIC link activity Off No link to network If the power is off view the rear panel RJ 45 LEDs for status Rear panel LEDs and buttons on page 12 Flashing green Network link and activity Solid green Network link AMP status Off AMP modes disabled Solid green AMP mode enabled Solid amber Failover Flashing amber Invalid configuration Over temp Off Normal Solid amber High system temperature detected All other LEDs Off Normal Amber Failure For more information on the activation of these LEDs see Systems Insight Display LED combinations on page 11 Component identification 10 Systems Insight Display LED combinations When the health LED on the front panel illuminates either amber or red the server is experiencing a health event Combinations of illuminated Systems Insight Display LEDs the system power LED and the health LED indicate system status Systems Insight Display System power LED and color LED Processor amber Amber One or more of the following conditions may exist Processor in socket X has failed Processor X is not installed in the socket Processor X is unsupported ROM detects a failed processor during POST Processor amber Amber Green Processor in socket X is in a pre failure condition DIMM DIMM amber Red Gre
118. the server The server supports variable fan speeds The fans operate at minimum speed until a temperature change requires a fan speed increase to cool the server The server shuts down during the following temperature related scenarios e At POST and in the OS HP iLO performs an orderly shutdown if a cautionary temperature level is detected If the server hardware detects a critical temperature level before an orderly shutdown occurs the server performs an immediate shutdown e When the Thermal Shutdown feature is disabled in RBSU HP iLO does not perform an orderly shutdown when a cautionary temperature level is detected Disabling this feature does not disable the server hardware from performing an immediate shutdown when a critical temperature level is detected Z CAUTION A thermal event can damage server components when the Thermal Shutdown feature is disabled in RBSU Component identification 20 Operations Power up the server To power up the server press the Power On Standby button Power down the server Before powering down the server for any upgrade or maintenance procedures perform a backup of critical server data and programs Wa IMPORTANT When the server is in standby mode auxiliary power is still being provided to the system To power down the server use one of the following methods e Press and release the Power On Standby button This method initiates a controlled shutdown of applications and the
119. ts can run 8 GT s signaling rate in either PCle2 or PCle3 mode depending on the capability of the installed processor tPCle slot 3 is connected to the southbridge and runs at the Gen2 signaling rate Notes e Primary denotes the riser cage is installed in the primary riser connector e Secondary denotes the riser cage is installed in the secondary riser connector e Installing the riser cages listed in the table above in either the primary or secondary riser connectors determines the form factor of the PCI cards supported by those riser cages e FL FH denotes full length full height HL FH denotes half length full height LP denotes low profile Component identification 13 e The PCle2 x16 riser cage supports a maximum power of 150 W with an HP power cable This cable must be used for PCle card wattages greater than 75 W Slot description example Slot 3 PCle2 x8 4 2 1 T Negotiable link width s Physical connector link width Gen signaling rate Slot number System board components Fan connector 6 Systems Insight Display connector Fan connector 5 5 Fencomecer FancomecirS SSCS Fan connector 3 Component identification 14 Power supply backplane connector SATA optical drive connector NMI jumper System battery 21 SD card slot Processor 2 socket 2 SAS connector 1 SAS connector 2 Cache module connector Processor 1 socket RDX power connect
120. uch as Bluetooth within power class below 10mW CE For EU non harmonized telecommunications products If applicable a 4 digit notified body number is inserted between CE and CEO Please refer to the regulatory label provided on the product The point of contact for regulatory matters is HewlettPackard GmbH Dept MS HQ TRE Herrenberger Strasse 140 71034 Boeblingen GERMANY Disposal of waste equipment by users in private households in the European Union Regulatory compliance notices 106 This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment The separate collection and recycling of your waste equipment at the E jie of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or the shop where you purchased the product Japanese notice TEA Ceo CVS BIC VCC 7 7 BEV Y CWE LEB KOMAX BHAT AV COMBI SATA BRARLIVHE CT ORBIT RR CHAT SO EX AME LCTWETA COREMIVACFT LEY a y FRR LT fASHOE SAMBA HIOPFICEBHO ED BARRA BIC HE
121. uipment by users in private households in the European Union cccceeeseeeseeeteeeteeneees 106 Japanese Notice errik ee eee 107 BOM MONGE cariou a E E E E E 107 IRONEGN NON Ge AEA EA TAE T 107 RUSS FI E A A E 108 Laser compliance eeeccesscessssceesseeeeeeecsseeeseeecseeessseeeseeeecsseeecseeeesseeesseeecsseceseeseeseeessseeesssesesseeecsseeeeeaeees 108 Battery replacement notice ccccccccesscessseccesececsseceeseeeesseeeceseeeseeecseeecseeeeseeecssecesseeesseeecssececsseeesteeeesseeenas 108 Taiwan battery recycling notice ccecceesscesseeeseeeseeeeseeeseeeeeceeceaeecseecnseeeseeeseeenseceaeeeeeenseseaeeeneeenseeneenteeens 109 Power cord statement for Japan sisssscssisscsssasssasnasinsssnssassssnasaissaawsasstaeaksassisstiaebioabiaabinasanssiassasssaaasabsesnsbansnasd 109 re Re Rt ah cea ica eet aera ec ee 110 Preventing electrostatic discharge i s sscs escserserscesnssensoestonssnseensesasosanenansuntevsnneaenesnseosaceaanesssovaseustanensasnens 110 Grounding methods to prevent electrostatic discharge cccceeceesseeesseeeseeeeeeeeeneeenseeeeesneeeeseeeeesteeeteeneeens 110 Fe PMS NU I tcc E E N E E O E A E etait NA A A EA 111 Environmental specifications nosenia r E E E E E E 111 Mechanical specifications ccccccsccccssscessececseceesseecsseeeesseeesseeecsseeessseeeeseeeesseeessecesseeeesseeecsseeesseesenseeesaeees 111 Power supply specifications cccccccsscccsssccsseeecssecessseecssececeseeeeseeecse
122. uration utilities presented in this section operate in online mode offline mode or in both modes Software or configuration utility HP iLO on page 90 Online and Offline Active Health System on page 91 Online and Offline Integrated Management Log on page 92 Online and Offline Intelligent Provisioning on page 92 Oftline HP Insight Diagnostics on page 93 Online and Offline Erase Utility on page 93 Offline Scripting Toolkit on page 94 HP Service Pack for ProLiant on page 94 Online and Offline HP Smart Update Manager on page 94 Online and Offline HP ROM Based Setup Utility on page 95 Offline Array Configuration Utility on page 97 Online and Offline Option ROM Configuration for Arrays on page 98 Offline ROMPaq utility on page 98 Offline Server QuickSpecs For more information about product features specifications options configurations and compatibility see the QuickSpecs on the HP website http h18000 www1 hp com products quickspecs ProductBulletin html At the website choose the geographic region and then locate the product by name or product category HP iLO Management Engine The HP iLO Management Engine is a set of embedded management features supporting the complete lifecycle of the server from initial deployment through ongoing management HP iLO The HP iLO subsystem is a standard component of selected HP ProLiant servers that simplifies initial server setup ser
123. ve parts Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis Wrist straps are flexible straps with a minimum of 1 megohm 10 percent resistance in the ground cords To provide proper ground wear the strap snug against the skin Use heel straps toe straps or boot straps at standing workstations Wear the straps on both feet when standing on conductive floors or dissipating floor mats Use conductive field service tools Use a portable field service kit with a folding static dissipating work mat If you do not have any of the suggested equipment for proper grounding have an authorized reseller install the part For more information on static electricity or assistance with product installation contact an authorized reseller Electrostatic discharge 110 Specifications Environmental specifications Temperature range Cd Operating 10 C to 35 C 50 F to 95 F 30 C to 50 C 22 F to 122 F 30 C to 60 C 22 F to 140 F eo inieaiadal temperature a noncondensing 10 to 90 5 to 95 All temperature ratings shown are for sea level An altitude derating of 1 C per 300 m 1 8 F per 1 000 ft to 3048 m 10 000 ft is applicable No direct sunlight allowed Storage maximum humidity of 95 is based on a maximum temperature of 45 C 113 F Altitude maximum for storage corresponds to a pressure minimum of 70 KPa Mechanical specifications H
124. ver health monitoring power and thermal optimization and remote server administration The HP iLO subsystem includes an intelligent microprocessor secure memory and a dedicated network interface This design makes HP iLO independent of the host server and its operating system Software and configuration utilities 90 HP iLO enables and manages the Active Health System on page 91 and also features Agentless Management All key internal subsystems are monitored by HP iLO SNMP alerts are sent directly by HP iLO regardless of the host operating system or even if no host operating system is installed Using HP iLO you can do the following e Access a high performance and secure Remote Console to the server from anywhere in the world e Use the shared HP iLO Remote Console to collaborate with up to six server administrators e Remotely mount high performance Virtual Media devices to the server e Securely and remotely control the power state of the managed server e Have true Agentless Management with SNMP alerts from HP iLO regardless of the state of the host server e Access Active Health System troubleshooting features through the HP iLO interface For more information about HP iLO features which may require an iLO Advanced Pack or iLO Advanced for BladeSystem license see the HP iLO documentation on the Documentation CD or on the HP website http www hp com go ilo docs Active Health System HP Active Health System provides th
125. wer capacity Verify that all power supplies have the same part number and label color The system becomes unstable and may shut down when it detects mismatched power supplies Label color Output Wre 750W aav DC 1200 Z CAUTION To prevent improper cooling and thermal damage do not operate the server unless all bays are populated with either a component or a blank To install the component 1 Access the product rear panel on page 23 2 Remove the blank Z WARNING To reduce the risk of personal injury from hot surfaces allow the power supply or power supply blank to cool before touching it Hardware options installation 61 3 Insert the power supply into the power supply bay until it clicks into place Connect the power cord to the power supply Route the power cord Use best practices when routing power cords and other cables A cable management arm is available to help with routing To obtain a cable management arm contact an HP authorized reseller Connect the power cord to the AC power source Be sure that the power supply LED is green Rear panel LEDs and buttons on page 12 FlexLOM option Z WARNING To reduce the risk of personal injury electric shock or damage to the equipment remove the power cord to remove power from the server The front panel Power On Standby button does not completely shut off system power Portions of the power supply and some internal circuitry remain active unt
126. wer to the equipment e Donotroute the power cord where it can be walked on or pinched by items placed against it Pay particular attention to the plug electrical outlet and the point where the cord extends from the server Installing the operating system This ProLiant server does not ship with provisioning media Everything needed to manage and install the system software and firmware is preloaded on the server To operate properly the server must have a supported operating system For the latest information on operating system support see the HP website http www hp com go supportos To install an operating system on the server use one of the following methods e Intelligent Provisioning The iLO Management Engine is a new feature on ProLiant servers that contains Intelligent Provisioning for embedded deployment updating and provisioning capabilities Intelligent Provisioning can configure the server and install an operating system eliminating the need for SmartStart CDs and Smart Update Firmware DVDs To install an operating system on the server with Intelligent Provisioning local or remote a Connect the Ethernet cable and then power on the server b During server POST press the F10 key Complete the initial Preferences and Registration portion of Intelligent Provisioning on page 92 A d Atthe 1 Start screen click the Configure and Install button e To finish the installation follow the on screen prompts