Home
        SDMProfiler UserManual
         Contents
1.  been altered    When you wish to save your selections click Exit  A Save As file window will appear   Enter the file name and directory where you wish to save the configuration file  You now  have a configuration file for the SICOM Display Module  You may save to a different  Profile file than the one that was being read  The file you save to does not have to be named  Profile but it must be renamed Profile and placed in the correct directory before the SICOM  Display Module will interpret it     When SICOM Profiler is used to create multiple configuration files  a naming  storage  strategy is recommended  A suggested way to work with a number of different  configurations is to save each by a new name     Profilel  Profile2 etc  or by a project name   Be sure to save the a  FeatureCodes txt file or the associated feature list with the project as well   To use the file with the SICOM Display Module  copy the file to the directory named in the  SICOM_PROFILE environment variable and rename it Profile before starting the Display  Module     Keeping files of each different Profile configuration implemented allows for replication of  an end user   s SICOM Display Module environment for testing and assistance  It will also be  easier to issue an updated version of SICOM Display Module to an end user without  introducing the possibility of a changed interface  When creating updated versions be sure  that you are working with the appropriate version of a  FeatureCodes txt  or the fe
2.  layers to be selected for visibility in the  Working and Overview boxes                 Layer Definitions and Options  Define Layer  Layer   Add Layer   VEGETATION  Layer2  Feature Codes PARC NAME  VEGE  NAME v   VEGE NAME  Complement  Add Feature   LABEL  LINE1  PT3CH  Remove Layer Feature   PTAMB  VEG BOX  I User Can Alter             Fig  IV 4 2 Layer Definitions and Options    Layers and features may be removed from the layer selection by highlighting the layer or  feature and clicking the Remove Layer Feature button     Selecting Auto Build Complement creates a layer named Complement that contains all the  features that have not been selected for any defined layer     The User Can Alter option permits the SICOM Display Module user to alter the layer  settings when they run the Display Module     Toggling between By Layer and By Feature will remove any of the layer and feature  display settings     SICOM Profiler Version User s Manual 10    SICOM Spatial Information Components    The Alter Default option for the Working and Overview display allows the SICOM  Display Module user to alter the defaults defined on this page  Alter Current allows the  user to change the values only during the current run of the Display Module     The Feature Selection control options define how features may be selected in the SICOM  Display Module  By Click allows feature selection by pointing the mouse at the feature and  clicking the mouse button  By Rectangle allows feature selection withi
3. CA Caris  2 1SupportFontdef fnt z    Variable     Value       Set   Delete      Fig  II 1 System Dialog Box       IV  Using SICOM Profiler    This section explains how to use SICOM Profiler     SICOM Profiler v 1 0 consists of six property sheet style pages  Each page may be used to  define a different category of the SICOM Display Module control settings  The page  categories are  Program Control  Main Window Control  Map View Control  Zoom Pan  Control  Feature Control and Data Readout Control     On starting the SICOM Profiler an Open file window is displayed to provide the option to  open up and work with an existing profile configuration file  The file name and directory  may be entered to enable this option  The file name defaults to the file pointed to in the  SICOM PROFILE environment variable  Input Profile files do not have to be named  Profile  another file of Profile format may be selected  Selecting Cancel from the Open file  window means that you will be starting from default values instead of from a previously  created file     Once the file or default values are loaded you may view and change the settings on any or all    of the pages  You may move to any page and change any value as often as you like  Page  setting desctiptions are provided in the following sections     SICOM Profiler Version User s Manual 4    SICOM Spatial Information Components    If you do not want to keep any of the changes  click Cancel and your input file  if any exists   will not have
4. RITI SICOM3 2  TECH 005    SDM PROFILER  SP     USER S MANUAL    Spatial Inf    Copyright O1 998 Reading Informeni    perron ot     may result in s  r are oil and ciminna penaltiss  ard    wall ba Pose ha Ih mama aan   possible under Ihe kra       Nov  20  2001    274 Main Street  Suite 302  Reading  MA 01867    Tel   781 942 1655  Fax  781 942 2161  Website  www riti com  E mail  riti riti com    READING INFORMATION TECHNOLOGY INC     SICOM Spatial Information Components    TABLE OF CONTENTS    SICOM PRORILER Nha 1  TABLE OF CONTENTS 10 000  c ceccccccecccecceccceececceecucceeceecuecaeecueceeceeceecaeeceecseeaeeseeeas 2  L  REP SO te 3  KL  What does Profiler do  nee een 3  Il  PROFILER ENVIRONMENT REQUIREMENTS        22 2 ceccecceceececceccececesceececaeceeeaees 3  IV  Using SICOM   s RR RR 4  IV 1  Program Control Page  NOT USED IN SICOM3 2               neeeneennennenene 5  IV 2  Main Window Control SJ 5  FE Map View LEE 0 EEE EN ianiai es raien i 7  IV 4  Feature Control Page  NOT USED in SICOM3 2                eeneeeneennenennennene 9  FG  EEE 11  IV 6  Data Readout Control Page  NOT USED IN SICOM3 2                 eneennene  12    SICOM Profiler Version User s Manual 2    SICOM Spatial Information Components    l  Who is Profiler for     Profiler is a tool for the SICOM application developer  Itis not for the SICOM end user   Systems are delivered to the end user with a Profile file generated by the Profiler  but without  the Profiler application itself  SICOM Displa
5. ature list  associated      IV 1  Program Control Page  NOT USED IN SICOM3 2     The Program Control page  Fig  IV 1  allows for plug ins to be enabled on the SICOM  Display Module  The only plug in currently defined is the Composition Module  To  enable a version of the SICOM Display Module to work with the plug in  select the plug in  on this page when defining the profile  A selected option will have a check mark in the box  to the left of the plug in title     IV 2  Main Window Control Page    The Main Window Control page  Fig  IV 2  may be used to define the window dimensions  and the look of the SICOM Display Module  The Initial Size can be set to Half Screen   Full Screen or Custom     in which case you must enter the width and height of the  screen in pixels  The Initial Position can be defined as either Centered or a Custom x  y  starting position  If you select Custom size or position you must enter values for them and  you must move out of the entry boxes for their values before moving to another page     A Title Bar can be set for the SICOM Display Module window  if the Title Bar option is  selected the string in the entry box to the right of the Title Bar option will be displayed at    the top of the window     The SICOM Display Module window may be set to be Resizable  Maximizable or  Minimizable by selecting the options on this page     SICOM Profiler Version User s Manual 5    SICOM Spatial Information Components       Fig  IV 1 Program Control Page    SICOM P
6. mation Components    IV 4  Feature Control Page  NOT USED in SICOM3 2     The Feature Control page defines feature display and selection for the map in use with the  SICOM Display Module  Feature display may be either By Feature or By Layer  Layers are  defined on this page  Feature code lists on this page are determined from the file pointed to  by the SICOM environment variable   SICOM_FEATURE_LIST  This file may have been  created by the Feature Lister application and is a text file   txt  consisting of the feature  codes  one per line  for the map being used  If there is no SICOM FEATURE LIST  environment variable then the default is a file named a  FeatureCodes  xt in the current    directory     If By Feature is selected then the Working and Overview list boxes will contain the list of  available features  Features need to be highlighted in order to be selected for display in the  working map view s  and in the overview  if used   Simply click on a feature in the list box  to toggle the feature as either selected or not  To select multiple features  hold down the  control key and click on each desired feature  To select a range of features  click on the first  feature in the range  press and hold the Shift key  then click on the final feature in the range   Only the highlighted features are selected and will be displayed in the SICOM Display  Module     PARCELS    LABEL  LINE 1   PARC NAME  PARCELS F         Fig  IV 4 Feature Control Page    SICOM Profiler Version User 
7. n a rectangle  and is  executed in the SICOM Display Module by clicking the mouse at the upper left hand corner   and  with the mouse button held down  dragging until the desired rectangle is     The Backdrop option is currently disabled   The Feature Addition option determines if it will be possible for the user to add features in  the SICOM Display Module  Selecting Add Features permits the user to add new transient    features  Selecting the Allows Persistence option permits the user to add new permanent  features     IV 5  Zoom Pan Control Page    The Zoom Pan Control page allows the definition of how SICOM Display Module will  allow zooming and panning on the map in view     Profiler    Iv  ml    BJ    8 Step SIZE    ja se can orende    Defaut Step Size    Ul ser ar werde       Apg J Jelp       Fig  IV 5 Zoom Pan Control Page    SICOM Profiler Version User s Manual 11    SICOM Spatial Information Components    Options for zooming are by Rectangle and by Steps  Zoom by Rectangle allows the  user to click and drag to define a rectangular area into which to zoom  Zooming by Steps  allows the user to zoom by a certain percentage with each zoom  If Zoom by Steps is  selected then a Default Step Size percentage must be entered  If the User Can Override  option box is selected then the SICOM Display Module user can change the zoom step  percentage at runtime     The Pan Control options allow the SICOM Display Module user to pan by Center at Click   to center their map display a
8. rofiler Version User s Manual 6    SICOM Spatial Information Components                Fig  IV 2 Main Window Control Page    IV 3  Map View Control Page    The Map View Control page is used to define the settings of the windows that display maps  within SICOM Display Module     Map views can be set to allow Multiple Views or Single Views  Multiple Views allow the  user to open a map  keep that view open and then open another view of that or another  map     The map that is opened  or its ditectory  may be predefined here by selecting Preload File     Click the Browse for Preload File button to reach the name and directory to be found on  the computer  The file or directory name may also be directly entered in the box above the    SICOM Profiler Version User s Manual 7    SICOM Spatial Information Components    browse button  If the User Opens file option is selected then the SICOM Display Module  user has the flexibility to open a map of their choice     CA Program Files RITI SICOM         Fig  IV 3 Map View Control Page    An overview window can be placed within the map view if the Use Overview option is  selected  With the Overview option selected  the Initial Size and Position of the overview  window can be defined as well as whether or not the overview window is Movable   Resizable and Minimizable     Setting the Allow Editing option permits the SICOM Display Module user to edit a map  that is not read only     SICOM Profiler Version User s Manual 8    SICOM Spatial Infor
9. s Manual 9    SICOM Spatial Information Components    The features displayed on this page are taken from the file to which the   SICOM FEATURE LIST environment variable points  If you load an existing profile  containing a different list of feature codes than the to which SICOM FEATURE LIST  points  then the features will not be displayed  Any feature codes that are common to both  the loaded Profile file and the set feature file list  and that were selected in the loaded Profile   will be displayed as selected  Should this situation occur and you wish to avoid over writing  previous feature selections loaded in the Profile  click Cancel and none of the changes made  to the Profile will be saved  Alternatively  you may click Exit and save the Profile file under  a different name  directory     If By Layer is selected then layers of feature codes may be defined  To define a layer  enter  the layer name in the box beneath Define Layer and click the Add Layer button  The new  layer should appear in the display box to the right  To add features to a layer  select the layer  in the display box so that the layer name is highlighted  then select a feature from the drop   down box below Feature Codes and click the Add Feature button  The feature should  appear as a branch of the selected layer in the display box  Multiple features may be added  to alayer  Multiple layers may be added  The same feature can be part of more than one  layer  Using layers instead of features allows entire
10. t mouse click   by Drag with mouse drag  by Scroll using  scrollbar  or by steps using Pan by Steps  If Pan by Steps is selected  then a Step Size    percentage must be entered  The User Can Override option for Pan by Steps allows the  Display Module user to change the step percentage at runtime     Multiple types of zoom and pan control options may be selected   IV 6  Data Readout Control Page  NOT USED IN SICOM3 2     The Data Readout Control page allows definition of point and vector readout on the map  displayed by the SICOM Display Module     Profiler      EPP       Fig  IV 6 Data Readout Control Page    SICOM Profiler Version User s Manual 12    SICOM Spatial Information Components    The Point Readout section allows definition of point readout by Pixel Location  Latitude  and Longitude and Northing and Easting  Any combination may be selected     The Vector Readout can be set to be by Length or Azimuth  or both     The length of units may be set as Kilometers  Miles or Nautical Miles  Only one unit of length  may be selected     SICOM Profiler Version User s Manual 13    
11. vironment variables in a Windows NT environment  follow these steps     1  Go to the Start menu  and select Settings  gt  Control Panel    2  Double click the System icon  The System Properties dialog box is displayed   Fig I11 1    3  Click on the Environment tab    4  Type in the path and file name in the Value text field and the variable name in  the Variable text field    5  When you ate finished  click on Set    6  When you have entered all needed environment variables click on Accept     In a Windows 95 or Windows 98 environment  variables may be set in the Autoexec bat file   by adding SET lines for the environment variables  saving the file and restarting the system     SICOM Profiler is currently supported by Windows NT and 2000  Windows 95 and  Windows 98 operating systems only          The installation script should take care of this  On the safe side  please verify it     SICOM Profiler Version User s Manual 3    SICOM Spatial Information Components        System Properties  2 px                   Startup Shutdown   Hardware Profiles User Profiles    General   Performance    System Variables           Variable Value  ComSpec CAWINNTY system32Ycmd exe  NUMBER OF PRO    1   OS Windows NT   Os2LibPath CAWINNT system32 os2 all   Path CAWINNT system32 C  WINNT  2        User Yariables for Administrator        SICOM_FEATURE_L    C  Program Files Riti SicomYT allFeatureCodes        SICOM_PROFILE C  Program Files Riti Sicom  T  Profile i  TEMP CATEMP  TMP CATEMP  uslXafm 
12. y Module reads and interprets the Profile file     ll  What does Profiler do     The SICOM Profiler controls the look and feel of the SICOM Display Module  It provides  access to the configurable attributes of the Display Module  allows capture of the developer   s  choices and produces a configuration file to be read and interpreted by the SICOM Display  Module  The configuration file may be read into the SICOM Profiler for any required  updating of settings     III  PROFILER ENVIRONMENT REQUIREMENTS     The SICOM Profiler makes use of an environment variable named   SICOM FEATURE LIST  The file associated with this variable is read to retrieve a list of  all the feature codes in the map that will be used with the end users system  This file may  have been created by the Feature Lister application and is a text file     x that consists of the  feature codes  one per line  for the map being used  If there is no   SICOM FEATURE LIST environment variable then the default is a file named  allFeatureCodes txtin the current directory  The map features visible with the SICOM Display  Module must first be selected to be visible by the Profiler  Map feature codes must be  provided to the Profiler in an appropriately formatted file and associated with this  environment variable     The SICOM PROFILE  environment variable is used to retrieve a default Profile filename  If  this variable is absent then the filename Profile will be used in the current directory     To set the Profiler en
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Chaudière TOK 22-29  Samsung HW-J250 دليل المستخدم  Carel EVD0004 PID controller with driver for two pole stepper valve  For DigiMUX - Fitch Security Integration  Black & Decker FusionBlade  PRODUCT MONOGRAPH  Craftsman 17" Drill Press with Laser and LED Light Owner's Manual  HX3 User's Guide - Honeywell Scanning and Mobility  Operating instructions SIGNOMAT S2000 and pneumatic workholder  Overmax OV-85in1    Copyright © All rights reserved. 