Home
LMP-0501 Series
Contents
1. 53 7 Technical Specifications 71 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 1 Introduction Antaira Technologies industrial managed switches come with a pre installed user friendly web console interface which allows users to easily configure and manage the units whether one is using a serial console and command line interface CLI commands like Telnet SSH HTTP Web GUI or simple network management protocols SNMP 1 1 Product Overview Antaira s LMP 0501 series is a 5 port industrial PoE managed Ethernet switch that is embedded with four 10 100Tx Ethernet ports that support either IEEE802 3af or IEEE802 3at for a maximum of 30 watts per port and one 100Fx SC or ST type fiber port in a multi mode 2Km or single mode 30Km option It is a fully manageable industrial Ethernet switch that supports the standard Layer 2 Ethernet configurable settings This product series is IP30 rated and DIN rail mountable There are two operating temperature models either the STD 10 C to 70 or the EOT 40 C to 75 It also provides high EFT and ESD protection for any industrial networking application within factory automation ITS power utility water wastewater and any other outdoor or harsh environment 1 2 Product Software Features p Network Redundancy gt STP RSTP MSTP ITU T G 8032 Ethernet Ring Protection Switch ERPS
2. 9 2 9 Wiring the Fault Alarm Contact 9 3 Mounting Installation 10 3 1 DIN Rail Mountmg 10 3 2 Wall MOUNING oir eene nonne et dee 11 4 Hardware Installation 12 4 1 Installation Steps 12 5 Web Management e eeerssee 13 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 1 Web Console Configuration 13 5 1 1 About Web Based Management 13 EEN 14 5 2 1 System Information 14 5 2 2 AOmllh PassWOLEO seende 15 De IE O N O e AAS 16 5 2 4 System Tme aa 17 5 3 Port Management Xa 18 EMP 18 5 3 2 Port Configuration occccocccccocncoccnccononononnnos 18 5 4PoE Power over Ethernet 19 5 4 1 PoE Configuration 19 522 RING AA dag p 20 e AA A 21 D EP 21 So BRPSSIIUSu AA 22 5 5 2 ERPS Configuration 23 5 5 3 Before Configuring ERPS 24 5 5 3 1 Scenario A RPL Configured Architecture26 5 5 3 2 Scenario B Non Configured Architecture29 Sr sje Ost ALLA MISS ENE 30 A AA 31 5 6 2 RSTP Configuration 31 5 5 9 MOT LO US Laastad 33 Antaira Industrial Ethe
3. Mode Root Priority Root Hello Time Root Forward Delay Root Ma xinum Age Figure 5 31 RSTP Configuration Interface 31 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Users can select RSTP or MSTP function to be enabled or disabled before configuring the related parameters A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as Root Priority 0 61440 the root If any change of the value the switch is required to be reboot The value must be multiple of 4096 according to the protocol standard rule Enter a value between 1 through 10 for the time to control Root Hello Time 1 10 the switch to send out the BPDU packet for RSTP current status checking Enter a value between 4 through 30 as the number of Root Forward Delay 4 30 seconds for a port to wait before changing from its RSTP learning and listening states to the forwarding state Enter a value between 6 through 40 as the number of Root Maximum Age seconds a bridge waits without receiving STP 6 40 configuration messages before attempting a reconfiguration Enter a value from 1 through 200000000 to define the path cost for the other switch from this transmitting switch Path Cost 0 200000000 8 at the specified port When path cost insert in 0 the switches will be setup as automatic data transmitting Enter a number 0 through 240 to decide which port should P
4. configure O ER Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 smtp receive 1 2 3 4 e mail address no smtp enable no smtp sender SMTP no smtp subject o IO IO O O O O IO 5 DID 1 51 1515 o olojlo o o ololo 9 9 9 99 3 o IO IO O DM Oo UE ME ECH EE E A E o EEE 5 5 5 5 5 5 5 5 5 cilclolo D A A a A EE 2 0 22 o0 o is lz RV ooo 9o 8 o lololo s amp 1 ol m Rm ge Se 2 alolalola lola T 8 amp IS amp me SE op E maa aa o Co mN e e D ololcio O als Alo lgs 6 be Salo Q HERE Q O G O D OD o go 3 lt O gt F gt Cp HI o 2 3 O o D lt D D 2 Q O D 7 lt n NO G O 2 lt lt D O 2 lt Y PWD n Inm ivn l nl nai ais is isiT isiTistl i v lv ealvi m JEF HEG BH GHETETHE olo o o o scc s sme zr DO O Du 0 no lo lo Dm m 3 3 131313 138 l lololo lolo lolo o 3 3 1313 3 lolololo o 2 lt lt 2 2 a 9 9 9 91918 18 8 8 8 amp Slnlonlalala DiolololololSslol l lo lt lt lt lo CT lu iSl iS loo leie la lc 1 DI DI Di Sie 12121223 lo Diailalalalalsx x xl lo vig e le leo lo D D alalala 5 S E e 5 Els 2 5 e PoB3s5s s 9 210 BIBIZ Q SID ci o mnoy 53131315 S g gt e ee AS Bal KS sjaja lt 5 g s E e em 53 3 3 57 o TS 3 5 5 2 ms m S 25s 512 21 7 oO Sian a s ba 2 o c l2 e lo 2 ciz p S 3 a IS TI
5. A D Step 2 Input a name for the new connection T New Connection HyperTerminal ES Edt View Call Transfer Help i Connection Description 2 xl 54 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Step 3 Select the COM port number termnial HyperTerminal R E iol xj File Edit View Call Transfer Help Del 6 3 ola el CT zi A termnial Enter details for the phone number that you want to dial Country region want y Area code D Phone number A Connect using D Cancel Disconnected Auto detect Auto detect SCROLL CAPS NUM Capture Print echo a Step 4 The COM port property settings are as follows 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control ermnial HvnerTermina Sr fr Dl xj COMI Properties j x Port Settings Bits per second 115200 Data bits a y Parity None y Stop bits 1 y Flow control None y Restore Defaults OK Cancel Apply Disconnected Auto detect Auto detect SCROLL CAPS NUM Capture Print echo 55 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Step 5 The Console login screen will appear Use the keyboard to enter the Username and Password then press Enter User Access Verification sername admin Password SWESH configure terminal CLI Man
6. e Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressly approved by the grantee of this device could void the user s authority to operate the equipment CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Industrial Ethernet Switches Industrial Grade PoE Managed Ethernet Switches User Manual Version 1 0 November 2014 This manual supports the following models e LMP 0501 M e LMP 0501 53 e LMP 0501 M T e LMP 0501 S3 T e LMP 0501 ST M e LMP 0501 ST S3 e LMP 0501 ST M T e LMP 0501 ST S3 T This document is the current official release manual Please check our website www antaira com for any updated manual or contact us by e mail support antaira com Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Table of Contents 1 Tit dee ei e 1 11 Gelee OVERV EN Luse 1 1 2 Product Software Features 1 1 3 Product Hardware Features 2 1 4 Package Content 2 15 Salely Precaullo BANG 3 2 Hardware Description 4 2 1 Physical DIMENSIONS aaret 4 pe OA LA GING EE D E ele OW RET PAR 5 SED NO O anda T 6 2 9 EET Nr 7 2620 FIDE PPP 7 AO EE 8 2 8 Wiring the Power Inputs
7. E O D lt 3 t o 3 mn o Q Ea o pama c mi configure configure configure configure configure configure o lo lao lalalo che SSN loolololol 3 3 2 ooo lololo lt e le le le le 2 2 3 3 3 3 O 02 12 Aa 5 Q Q a lololo o GISJ 3 3 13 O ho ja la a S Ss Is loo 0 95 DIO Z O D lt s 2 255 amp 9 o mp I P 3 3 515681338 OQ Y O o o a OA 5 m h D E gt O D m Z D lt Mm D o O gt configure D lt to 2 e o lt o O O o o Se o e S zl D gt D e D configure configure configure e configure configure configure 5 5 1 0 0 0 0 o o51 2 3 5 S F 8 a a ce D D D D DM D all ll pla 1315155 SB a VE NE IE Be ei S N 3 23 Ire x lt lt ee t cms E A o o0 wn D QD N n sis la o o o ve lt ID O O O 131 131 3 3 a a O Q Q Q D ND O o 75 o9osz 3 3 1 9 9 o o D CIS oO Zi 353ilc Oo0gg 2 ole S LEE CANG O IO I r 13813 DIO 1 D OC oio lei SIS IC 20 0 DIO N Z Ig ll A sc MEHN KE Zo e ee ee O D Q m 1 O 4 3 2 Vio Z m 3 NIT gio JJ c O D gt m D O D 2 TI Z Y gt o Z D gt In lt Im c re o c O S Q 2 O configure gt o lt 3 e o lt e O O o o E o e D a O CO Antaira Industrial Ethernet Switches LMP
8. Green Of Powerinput1isinactive Powerinput2is active Green 498 Powerinput2isinactive On oystem is ready Off System is booting On EEE pem ia COE ERPS Owner Mode ng Master is ready E ECCO 7 o RR GB On a Network is active o Green Green Connected to network 10 100Mbps Flashing Networking is active Off Not connected to network On The port is supplying power to the powered device Off No powered device attached or power supplying fails WEN Connected to network 100Mbps Green S Networking is active Not connected to network Table 2 1 LED Indicators for LMP 0501 Series Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 2 5 Ethernet Ports Kal RJ 45 Ports RJ 45 Ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T 100Base TX connections Auto MDI MDIX means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures as below for straight through and crossover cabling schematics u RJ 45 Pin Assignments Table 2 2 Table 2 2 HJ45 Pin Assignments Note and signs represent the polarity of the wires that make up each wire pair All ports on this industrial Ethernet switch support automatic MDI MDI X operation Users can use straight through cables see figure below for all network connections to PCs servers other switches or hubs With st
9. Ring Port 1 Port Role Normal Ring ID Channel So C3 ce a a a Revertive e m iun a Figure 5 29 Non Configured Architecture Setup 5 6 Spanning Tree The Spanning Tree Protocol STP defined in the IEEE Standard 802 1d can be created within a mesh network of connected layer 2 switches The Rapid Spanning Tree Protocol RSTP defined in the IEEE 802 1w RSTP is an enhanced solution of STP It shares most of its basic operation characteristics and essentially creates a cascading effect away from the root bridge where each designated bridge proposes to its neighbors to determine if it can make a rapid transition Another extension of RSTP is the Multiple Spanning Tree protocol MSTP defined in the 30 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 IEEE802 1s It allows different VLANs to travel along separate instances of spanning tree Unlike STP and RSTP MSTP eliminates the needs for having different STP for each VLAN Therefore in a large networking environment that employs many VLANs MSTP can be more useful than legacy STP 5 6 1 RSTP Status Figure 5 30 shows the RSTP algorithm results RSTP CIST Status Root Status 8 000 7C CB 0D AD DC 14 Path State Port Cost ST Oper Edge Figure 5 30 RSTP Information Interface 5 6 2 RSTP Configuration Users can enable disable the RSTP function and set the parameters for each port RSTP CIST Configuration
10. SS ne Es gt o Io Io Io Io Io Io Io loo loo lp o oi ee T en bam I A ma m oa o D jab jab jab jab jab jab jab jab Q lt lt 5 O lololo lololo lololo lD l olo O alala ela Hilo le EE o a lalalala 9 o 2 3 E 3 5 D QD D m E o 5 j SE LS aa E EE VENNENE TI oO G 3 0 D 18 3 3 D 2 s bi dm e E gt ct OD lt 2 lol oo O D 3 cim 5 0 E Z x E O lt lt Q U O Qo gt o 3 oi O o E Er O ka rr lt D U e Ha 310 AE Ox 9 O JJ O 3 O 5 O D D o D C O D lt Qo Lamm D m c D configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure OD O Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 MIRROR both port list show monitor enable show monitor source 09 D gt D a z lalala lE O 2833322 3 S5 VEE O rl rl OND 3 S IESUS VS O alo lo I IS o 2 S EIRIS o 2 jojo x 5 5 3 gs O o 5 m Lo O mi 2 3 O D GER Q O gei Q D C i o O 3 D Q E D 7 t O ret z nm qos map cos priority_ty
11. Tx Ar A Rx TX Ba B Rx Figure 2 6 Fiber Ports Connection Caution This is a Class 1 Laser LED product Don t stare into the laser LED beam 2 Cabling m Twisted pair segments can be connected with an unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard e g Category 5 5e or 6 The cable between the equipment and the link partner switch hub workstation etc must be less than 100 meters 328 ft long lic Fiber segment using single mode connector type must use 9 125um single mode fiber cable B Fiber segment using multi mode connector type must use 50 or 62 5 125 um multi mode fiber cable Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 2 8 Wiring the Power Inputs Please follow the steps below to insert the power wire 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 7 Figure 2 7 Power Terminal Block V1 V1 V2 V2 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 8 Figure 2 8 Power Terminal Block Note e Only use copper conductors 60 75 C tighten to 5Ibs e The wire gauge for the terminal block should range between 18 20 AWG 2 9 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connec
12. o o o 1 d di 1 Figure2 1 LMP 0501 Series Physical Dimensions Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 2 2 Front Panel The front panel of the LMP 0501 series industrial PoE managed Ethernet switches is shown below in Figure 2 2 6 Pin Removal Terminal Block Power Input LED for PWR1 LED for PWR2 LED for FAULT LED for OWNER Ring Master LED for RING Ring Status 100Fx Fiber Port HESSE AUNG LED for Fiber Port Link Activity RJ45 for Serial Console RS232 LED for Ethernet Port Status USB for Configuration backup 10 100 Tx Ethernet Port LED for PoE Power Status Figure2 2 The Front Panel of LMP 0501 Series 2 3 Top View Figure 2 3 below shows the top panel of the LMP 0501 series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 48 55VDC PR Fam PWR 1 E th Frame Ground Figure2 3 Top Panel View of LMP 0501 Series Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 2 4 LED Indicators There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and network status Each LED indicator has a different color and has its own specific meaning see below in Table 2 1 P1 Owner Ring LAN Port 1 4 Left LED LAN Port 1 4 Right LED PoE Indicators Fiber Port 5 LNK ACT On Powerinput1is active
13. 0501 Series User Manual V1 0 no event syslog interface INTERFACE NAME up down show event syslog authentication failure show event syslog erps change show event syslog interface INTERFACE NAME up down event alarm power1 enable event alarm power2 enable event alarm interface INTERFACE NAME up down show event alarm power1 show event alarm power2 show event alarm interface INTERFACE NAME up down event apply syslog server IP address SYSLOG no syslog mode show syslog server show syslog mode show syslog log smtp enable smtp sender E MAIL ADDH smtp subject subject text smtp server address GMAIL SMPT SERVER smtp server port GMAIL SMPT SERVER eO IO 5 o SD D gt D 313 o lt olo o e o 513 SE e 2 9 oigo n Q Ia Io c c o 3 3 15 15 D D nla DO ee 5135 D oc E ilz 3 3 3 O O 9 o8 a ee me ee 5 0 O olo gt 31616 sis DIS lt c o Iiis 0 5 D E D p 3 GE kn e D D Z 3 4 D Q TI G o T lt gt gt O i d gt Z O gt O lt O m G rr Cc A ka o O configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure
14. Apply button to save changes Figure 5 60 SMTP Setting Terms amp Value Description 5 12 4 Event Selection Users can select any event type through the Event Selection interface such as System Cold J tt 5 17 5 tt Start any ports Link Up Link Down Link Up 8 Link Down and send the system warning massage to either SYSLOG or SMTP or both at the same time After the event selection users can click the Apply button to save changes Event Selection EVENT SELECTION SYSLOG SMTP Figure 5 61 Event Selection Setting Interface 47 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 12 5 Fault Alarm When any selected fault event has occurred the fault LED of the switch s front panel will light up and the electric relay will signal at the same time Users can check the checkbox of any Fault Alarm type such as power failure port link down or broken through the Fault Alarm setting interface to trigger this function Fault Alarm FAULT ALARM Power1 Failure Power2 Failure Porti Link Down Broken Port2 Link Down Broken Port3 Link Down Broken Port4 Link Down Broken Port5 Link Down Broken Port6 Link Down Broken 5 13 MAC Table The MAC address table is the filtering database that supports queries by the forwarding process as to whether a frame received by a given port with a given destination MAC address is to be Figure 5 62
15. C A 192 168 1 254 Mode name LMP 0602 IP Address 192 168 1 151 MAC 7CCB OO AD DC 14 Femm re Version 22 1 Status Basic Settings Port Management Po Status ERPS Spanning Tree 02 10 VLAN o MAC gt a Mirroring MODE i A System Warning IP Address MAC Table Mask D Maintenance Gateway Configuration DNS Server D Logout Figure 5 2 Web Console Main Status Page 5 2 Basic Setting 5 2 1 System Information Below Figure 5 3 shows the switch system setting information ancaira Model nare LMP 0602 IP Address 192 168 1 151 MAC 7C CB 00 AD DC 14 Firmware Version 2 2 1 Status Basic Settings antara Admin Password IP Setting System System Time Port Management SWITCH SETTING POE t BS System Name Spanning Tree ae system Description L Port Mirroring System Location 7 SNMP System Warning System Contact OJ MAC Table Maintenance Configuration Logout Figure 5 3 Switch Settings Status Page 14 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Terms System Name System Description System Location System Contact Value Description Factory Default Switch Users can assign any name label to identify this managed node By convention a domain name is a text string drawn from the alphabet A Z a z digits 0 9 minus sign No space characters are permitted as part of a na
16. EOT 40 to 75 Temperature C 40 to 167 F Environmental Storage Temperature 40 C 85 40 F 185 F Ambient Limits 5 to 95 non condensing Relative Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 CO em CE EN6100 4 2 3 4 5 6 8 CE EN6100 6 2 Regulatory EN6100 6 4 Approvals IEC60068 2 32 Free fall otability l IEC60068 2 27 Shock Testing IEC60068 2 6 Vibration UL 508 Pending Table 7 1 LMP 0501 Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu info antaira eu www antaira com tw info antaira com tw 13
17. Event Selection Setting Interface forwarded through a given potential transmission port 5 13 1 MAC Address Table MAC Address Table MAC Address Table Figure 5 63 MAC Adaress Table Interface O0 00 21 ff ff ff 00 20 4a ea 70 d3 00 30 ab 26 cb 04 00 50 7f 47 22 8a O1 00 5e 00 01 3c 01 00 5e 7f ff fa 10 bf 48 5a b4 0d lc afif7 7c 5b f amp 30 85 a9 a7 9d 63 30 85 a9 a8 05 bb 44 156d 57 47 27 04 48 5b 39 d1 1f 06 54 53 ed af 5c bd Z7cicb 0d 08 01 5e e0 3f 49 87 44 c2 ec 43 f6 6f 90 fd fd ce d6 cB 01 9f learning learning learning learning static static learning learning learning learning learning learning learning learning learning learning Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 13 2 MAC Table Configuration Users can check the checked box of each port and insert the port s VID and MAC address of the device that is connected to that port then click the Add button to continue adding other ports information Click the Apply button to save all the settings MAC Table Configuration MAC Table Configuration Figure 5 64 MAC Table Setting Interface 5 14 Maintenance Under the maintenance section users can execute updated firmware upgrades system reboots and reset the system to factory default 5 14 1 Upgrade Antaira is continuously developing new functions and features for specific application requirements for the industria
18. MSTI So one link can be active for one MSTI and the other link active for the second MSTI This enables some degree of load balancing and generally two MSTI s are used in the network for easier implementation 5 6 3 MSTI Status Users can display the MSTI root status and port status by selecting the instance ID number from 1 to 15 by clicking on the dropdown box from the MSTI Status interface MSTI Status Instance ID 1 v Root Status Root Priority Figure 5 33 MSTI Status Interface 33 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 6 4 MSTI Configuration Users can display the MSTI root status and port status by selecting the Instance ID number from 1 to 15 by clicking on the dropdown box from the MSTI Status interface MSTI Configuration Figure 5 34 MSTI Configuration Interface MTSI Configuration Users can insert the unique MAC address of the bridge switch Instance No amp VLAN There are 1 15 instance number user can insert which VLAN Group info into the belonging Instance number A value used to identify the root bridge The bridge with the lowest value has the highest priority and is selected as the root Priority 0 61440 The switch is required to reboot when there s any value change The value must be multiple of 4096 according to the protocol standard rule 34 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual
19. clear port1 interface interface name o O IAA D 2 FE 5 ICE jd cl Sia o O O O 5 3 1319 E o 515 3 3 3 29 g o 3 S 8 8 2 Es 3 Gio Y Al O ro 2 2 Boo o 3 og E zz 0 OD mg O S S s 2 olg o T z 3 zz si S ese o 2 S5 G a o o8 3 olol c 39 S pes 2 SS E E O O O g 51315 2138 sa 8 8 o 3 3 3 3 S I 3 DE 3 e cio D O Oo O9 D eee S dE S alala s S 38 E em NIN N P S9 E o olo 3 3 Or Sp ae o le H 5 S CH S o amp S Ge o P E T bel cr 3 O S timer guard time timer wtr time no portO no port1 no ring id no timer guard no timer wtr interface vlan vlan configure configure interface interface interface interface g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 g8032 O gt O Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 interface interface interface o O O o O O O O D D D D s s s 35 3 3 3 SISISIS D D D D D Q D D eo s c lt 9 D interface power inline priority priority_value interface interface interface configure configure interface interface interface interface interface interface interface configure configure configure o IO IO O O O O DID DIO IO O lO 3l3l3 3 3181312 2 82 S 2 8 CCS SCHEER ECKER NGS lo
20. configuration by web browser 5 1 1 About Web Based Management All of Antaira s industrial managed switches are embedded with HTML web console interfaces that have a flash memory on the CPU board It is a user friendly design with advanced management features that allow users to manage the switch from anywhere on the network through any Internet browser such as Internet Explorer version 9 0 or above is recommended Firefox Chrome and many others Preparing for Web Console Configuration Antaira s industrial managed switches come with a factory default value as below BM Default IP Address 192 168 1 254 B Default User Name admin M Default Password admin System Login 1 Launch any Internet browser 2 Type in factory default IP address http 192 168 1 254 of the switch Press Enter S c Q fi C http 192 168 1 254 cave sol Model name LMP 0602 IP Address 192 168 1 151 MAC 7C CB 00 AD DC 14 Firmware Version 2 2 1 Authorization Required Please enter your username and password Figure 5 1 Web Console Login 3 Thelogin screen appears 13 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 4 Key in the default username admin and password admin 5 Click the Login button then the main status page of the Web Console will appear as below Figure 5 2 The online image of the switch will display the real time ports connection status l0 ETC
21. o 3 tc zlo o a 3 ex c SE e S alols e G olla lt 2 EE gt ol His oz 59 Ua NE configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure O OT Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 snmp trap version 1 2c 3 traps inform snmp trap community trap community name snmp trap inform retry retry time intervall snmp trap v3 user user ID snmp trap v3 level auth noauth priv snmp trap v3 engine ID enginelD show snmp trap enable show snmp trap host show snmp trap version show snmp trap community show snmp trap inform retry show snmp trap inform timeout show snmp trap v3 user show snmp trap v3 level show snmp trap v3 engine ID show snmp trap v3 auth show snmp trap v3 encryption Q O O lt om c 2 3 Q Q O 5 gt Q o e Di gt o Q O gt O FILE PORT Q O 5 ED c 5 5 Q O 5 LED o Ta Ta Ta Ta Ta Ta ISI SIS IS To lv o 7 o 0 10 10 1 01601016060 10101013 5 5 5 om lo loa laoa lo loa loa lo loa loa loa 3 3 3 3 51313135 13131513 15 15 5 15 Ke O 31313 ee 113513 31033
22. startup config usb test file WES tconfigt m Fill in the folder and filename behind the copy startup config usb command Ex filet folder file2 68 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 3 CLl enable gt configure terminal gt copy usb startup config path EM Telnet 192168219 User ccess Verification Username admin Password SWES gt en SWESH configure terminal SHES config gt copy running config startup config usb SWES lt config gt copy usb startup config firmware SWES lt config gt copy usb startup conf iy destination file firmware destination file SHES Cconfig gt copy usb startup config filel Fill in the folder and filename behind the copy usb startup config command Ex file1 folder file2 4 CLI enable gt configure terminal gt copy usb firmware path E Telnet 192 168 219 User Access Verification Username admin Password SWES gt en SWESH configure terminal SWES configoH copy usb firmware file Fill in the folder and filename behind the copy usb startup config command Ex file1 folder file2 69 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 CLI enable gt configure terminal gt Syslog mode usb or all EN Telnet 192168219 JE we o vc EI So User Access Verification Username admin Password SWES gt en SWESH configure terminal SWES c
23. to disable RSTP or MSTP Step 1 Login to the switch with a web browser Step 2 Open the RSTP Configuration page under the Spanning Tree manual as shown below in Figure 5 21 um F F F F F Status Basic Settings Port Management Dot ERPS Spanning Tree RSTP Status MSTI Status MSTI Configuration MSTI Port Configuration IGMP Snooping Figure 5 21 Spanning Tree Manual 24 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Step3 When the RSTP CIST Configuration page shows up set Mode to Disable as shown in Figure 5 22 RSTP CIST Configuration RSTP CIST Mode RSTP RSTP Root Priority MSTP Disable Root Hello Time ECC A Root Forward Delay Root Maximum Age Figure 5 22 RSTP CIST Configuration Interface Step 4 Press the Apply button in the lower right corner Figure 5 23 RSTP CIST Configuration RSTP CIST Mode Root Priority Root Hello Time Root Forward Delay Root Maximum Age Figure 5 28 RSTP CIST Configuration Interface 25 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Ethernet Ring Protection Switch ERPS is an Ethernet ring protection protocol that is used to prevent forming a loop with LAN thus the broadcast storm problem could be avoided The loop avoidance mechanism ensures that traffic flows on all links except the RPL ring link In order to achieve the loop avoidance mechanism
24. 802 1Q VLAN settings Terms 8 Value Description 5 8 IGMP Snooping The Internet Group Management Protocol IGMP is a communications protocol used to manage the membership of Internet Protocol multicast groups IGMP is used by IP hosts and adjacent multicast routers to establish multicast group memberships When IGMP snooping is enabled in a switch it analyzes all the IGMP packets between hosts connected to the switch and multicast routers in the network When a switch receives an IGMP report for a given multicast group from a host the switch adds the host s port number to the multicast list for that group When the switch hears an IGMP leave it removes the host s port from the table entry IGMP snooping can reduce multicast traffic from streaming and other bandwidth intensive IP applications more effectively A switch using IGMP snooping will only forward multicast traffic to the hosts in that traffic This reduction of multicast traffic reduces the packet processing at the switch at the cost of needing additional memory to handle the multicast tables and also decreases the workload at the end hosts since their network cards or operating system will not 37 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 receive and filter all the multicast traffic generated in the network IGMP has 3 versions IGMP v1 v2 and v3 and support query group up to 256 groups 5 8 1 IGMP Settings opine Configuration IGMP SNO
25. 802 1Q specification standard and it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into the Ethernet frames Tag contains a VLAN Identifier VID that indicates the VLAN numbers Ports in a port based VLAN are referred to as untagged ports and the frames received on the ports as untagged frames The names derive from the fact that the frames received on a port do not contain any information that indicates VLAN membership and that VLAN membership is determined solely by a port s PVID All of Antaira s industrial managed switches have a default VLAN setting set to none for each port so the users can login to the VLAN setting interface to create a VLAN Group name and choose Tag or Untag for each port 802 1Q VLAN 802 10 VLAN Figure 5 38 802 1Q VLAN Settings Interface 36 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 7 2 802 1Q VLAN Settings 802 1Q VLAM Port 3202 10 VLAN Port Filter Figure 5 39 802 1Q VLAN Settings Interface PVID Users can assign a Port VLAN ID for each port Users can choose any port be Tagged or Untagged Tagged VLAN set the tagged PVIDs to carry different VLAN frames to other switch Untagged VLAN set the port PVID for untagged devices that connect to the port The range of PVID is 1 to 4094 Click the Apply button to save changes Figure 5 40
26. Apply button on the right bottom corner of the interface Then the system event logs will display within the SYSLOG LIST window The SYSLOG LIST will contain up to 5 pages of system event log information Users also can click the Refresh button to have the most updated system event logs information to display System Event Log SYSLOG LIST Figure 5 58 System Event Logs Interface 5 12 3 SMTP Setting The Simple Mail Transfer Protocol SMTP is for e mail transmission across the Internet SMTP Setting SMTP E mail Alert SMTP Server Address Sender E mail Address Mail Subject Authentication Username Password Recipient E mail Address 2 Recipient E mail Address 3 pb Recipient E mail Address 1 Ir E DoT Recipient E mail Address 4 Figure 5 59 SMTP Setting Interface 46 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 E mail Aen Enable Disable transmission system warning events by e mail SMTP Server Address Setting up the mail server IP address Sender E mail Set up the email account to send the alert Address Mail Subject The subject of the mail Check the box to enable the Authentication function Authentication Username the authentication username Password the authentication password Recipient E mail User can setup up to 4 recipient E mail addresses to receive Address es any system warning message Click the
27. Frame IEEE 802 3x for full duplex mode back pressure for half Flow Control duplex mode VLAN Groups 0 4094 IGMP Groups Up to 256 4 10 100BaseTx PSE 30W Port auto negotiation Ethernet RJ45 Port speed Full Half duplex mode and auto MDI MDI X Or connection PoE Pin V V V V for pin 1 2 3 6 Endspan MDI Assignment Alternative A Fiber Port 1 100Fx SC or ST connector with Multi mode in 2Km Port Interface 71 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 50 125um 62 5 125um or Single mode in 30Km 9 125um 10 125um Wavelength 1310nm Multi or Single mode RS232 Serial 1 RS232 in RJ45 connector with console cable Console 115 2Kbps 8 N 1 Configuration Backup 1 USB 2 0 Overload Power Reverse EE Polarity Present CPU Watch Dog Present 10Base T 2 pair UTP STP Cat 3 4 5 cable 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Per Unit Power 1 Green Power 2 Green Fault Red Per Port Link Activity Green Network Cable LED Indicator PoE Feeding Power Green Housing Metal IP30 protection Mechanical Characteristics wh Power Connection 1 removable 6 contact terminal block PoE Power 25W 48VDC per PoE port 30W 51 55VDC Output per PoE port Power Requirements Power Consumption 10 Watts no PD included 130 Watts Fully loaded Operating STD 10 to 70 C 14 to 158 F
28. GI XC air a LMP 0501 Series 5 Port Industrial PoE Managed Ethernet Switches 4 10 100Tx 30W Port 1 100Fx 48 55VDC Power Input User Manual Version 1 0 Antara www antaira com Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 O Copyright 2014 Antaira Technologies LLC All Rights Reserved This document contains information which is protected by copyright Reproduction adaptation or translation without prior permission is prohibited except as allowed under the copyright laws Trademark Information Antaira is a registered trademark of Antaira Technologies LLC Microsoft Windows and the Windows logo are the trademarks of Microsoft Corp NetWare is the registered trademark of Novell Inc WMM and WPA are the registered trademarks of Wi Fi Alliance All other brand and product names are trademarks or registered trademarks of their respective owners Notice Copyrights O 2014 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the pr
29. ITU T G 8032 defines three roles in ERPS which are RPL Owner Node RPL Neighbor Node and Normal Node Below are two scenarios that describe how to configure the ERPS using Antaira s industrial managed Ethernet switches Users can reference it to configure the managed switch as an RPL configured architecture shown in Figure 5 24 or as a non configured architecture shown in Figure 5 25 5 5 3 1 Scenario A RPL Configured Architecture Under scenario A there are three major roles that are required to be configured within the ERPS configuration RPL ring port neighbor RPL ring port Owner RPL Ring Protection Link RPL Neighbor Owner Node Node Port 1 Port 2 Port 2 Port 1 Normal Normal Node node Port 1 Normal Normal Node node Figure 5 24 RPL Configured Architecture Caution Before enabling any ERPS protocols on any of the Ring Nodes please DO NOT connect the switches to form a loop ring network just yet There should be at least one ring port left unplugged until all nodes in the topology are ready 26 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 RPL Owner Node There is only one RPL owner node that should be set in a ring network In order to set up the RPL owner node choose a switch and enable the Protocol under the ERPS configuration interface and then follow the steps below using Figure 5 25 as an example otep 1 Choo
30. Load config cfg If all of them don t exist it does not work Select USB Auto Backup it can auto Backup running config file USB Auto Backup from the Switch to the USB And the file name is startup config Figure 5 73 USB Auto Load and Backup Setting Terms 8 Value Description 5 16 Logout Users can logout of the web console interface by pointing at and clicking logout from the menu 6 Command Line Interface Management 6 1 About CLI Management Besides WEB based management LMP 0501 series also supports CLI management Users can use the console or telnet to manage the switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before configuring with an RS 232 serial console use an RJ45 to DB9 F cable to connect the switches RS 232 Console port to the PC s COM port 53 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Follow the steps below to access the console via RS 232 serial cable Step 1 From the Windows desktop click on Start gt Programs gt Accessories gt Communications gt Hyper Terminal Le Accessibility im Communications d HyperTerminal Le Network Time Protocol gt Network and Dial up Connections Le System Tools Le HyperTerminal A Acrobat Reader 5 0 114 Address Book EN Calculator EN command Prompt CN NetTime a Notepad W Paint Bj Windows Explorer 4 y WordPad e Network Associates d Startup nal start
31. OPING IGMP Snooping Enable Ouerier Enable Query Interval s Query Max Response Time s 10 Figure 5 41 IGMP Snooping Settings Interface IGMP Protocol Check the box to enable or disable IGMP Snooping Switch will be IGMP querier or not There should have the existing one and only one IGMP querier in an IGMP application up to 256 Groups The frequency at which the querier sends query Query Interval messages Query Max Response Time The maximum response time advertised App Click the Apply button to save changes Figure 5 42 IGMP Snooping Settings Terms amp Value Description 5 8 2 IGMP Snooping Status Table Multicast filtering is the system by which end stations only receive multicast traffic if they register to join specific multicast groups With multicast filtering network devices only forward multicast traffic to the ports that are connected to registered end stations 38 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 IGMP Snooping Table IGMP SNOOPING TABLE Group 239 0 0 1 239 0 0 2 NE PN Figure 5 43 IGMP Snooping Status Table 5 9 QoS Traffic Prioritization Network traffic is always unpredictable and the only basic assurance that can be offered is the best effort traffic delivery To overcome this challenge Quality of Service QoS is applied throughout the network This ensures that network traffic is prioritized according to specified cr
32. P Client IP Address Subnet Mask Gateway DNS Figure 5 7 IP Setting Information Terms Value Value Description WW Lo MN Client Enable the client by checking this box If DHCP fails and the configured IP address is zero DHCP will retry If DHCP fails and the configured IP address is non zero DHCP will stop and the configured IP settings will be used The DHCP client will announce the configured System Name as hostname to provide DNS lookup IP Address The unit default IP is 192 168 1 254 Assign the IP address that the network is using If DHCP client function is enabling user does not require assigning the IP address The network DHCP server will assign the IP address for the switch and it will be display in this column mill the subnet mask of the IP address If the DHCP client function is mendi the user is not required to assign the subnet mask Assign the network gateway for the switch If DHCP client function is Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 ERE enabled the user is not required to assign the Gateway DNS Assign the DNS IP address Click the Apply button to save changes Figure 5 8 IP Setting Information Description 5 2 4 System Time System Time NTP Local Time Sat Feb 26 02 22 48 2000 Select Your Time Zone Enable NTP Client Time 5erver Figure 5 9 System Time Settings Users can define the switch
33. S configuration interface and choose a specific port number under Ring Port O and set it as the Normal node by clicking the dropdown box of Role then set another specific port number under Ring Port 1 as the Neighbor node as shown below in Figure 5 26 So the link between neighbor port and owner port forms the ring protection link RPL After the configurations press the Apply button on the bottom right corner to save the settings Note The port number of Ring Port 0 and Ring Port 1 cannot be duplicated ERPS Confisuration ERPS Confi ure Protocol Enable Ring Port 0 Port Role Normal Y Ring Port 1 Port Role Ring ID Channel Revertive Figure 5 26 RPL Neighbor Node Setup Example 28 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Normal Node Users should setup the rest of the managed switches by setting the Role for both Ring Port 0 and 1 as Normal Node as shown above in Figure 5 27 Please be sure no duplicate port number has been chosen within a managed switch s ERPS ring setting the incorrect configurations may lead to unexpected errors ERPS Confisuration ERPS Confiqure Protocol Ring Fort 0 Port1 Role Normal Ring Port 1 Port Role Normal Ring ID Channel Revertive Figure 5 27 RPL Normal Node Setup Example 5 5 3 2 Scenario B Non Configured Architecture In some situations users can choose not to con
34. V1 0 Apply Click Apply button to save changes Figure 5 35 MSTI Configuration Terms amp Value Description MSTI PORT Instancal Cost Port i Port Ports Porta Port Porte Proorrbr Porti Port A Port 3 Port4 Ports Porth User can select Instance Tab 1 15 to configure each Instance Tabs o MSTI port Cost amp Priority value User can define the path cost value from 1 through 200000000 to the other bridge from this transmitting bridge at the specified port User can decide which port should be blocked by priority in LAN by select the value from 0 to 240 from the dropdown box Click the Apply button to save changes Figure 5 37 MSTI Port Configuration Terms amp Value Description 35 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 7 802 1Q VLAN A Virtual LAN VLAN is a logical network grouping that limits the broadcast domain which allows a user to isolate network traffic Only the members of the VLAN will receive traffic from the same members of VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still physically plugged into the same switch The switch supports port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is at 802 1Q 5 7 1 802 1Q VLAN settings Tagged based VLAN is an IEEE
35. ace configure configure configure interface interface configure configure configure interface interface configure configure configure configure configure configure interface configure configure configure configure configure O N Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 no igmp snooping querier no igmp snooping fast leave show igmp snooping mdb show igmp snooping all show igmp snooping fast leave Save and Load Configuration File to from USB 1 CLI enable gt configure terminal gt copy running config usb path Em Telnet 192 168 2 19 User Access Verification Username admin Password SWES gt en SWESH configure terminal SWES tconfig H copy running config startup config usb SWES config H copy running conf iq startup config usb SWES config copy running config usb filel SWES config copy running config usb test rf ile SWESGCconfig gt it m Fill in the folder and filename behind the copy running config usb command Ex filet folder file2 2 CLl enable gt configure terminal gt copy startup config usb path EM Telnet 192 168 2 19 User Access Verification Username admin Password SWES gt en SWESH configure terminal SHES conf ig gt it copy runninuy config startup config usb SHES Cconfig copy startup conf ig runninuy config usb SHES Cconfig t copy startup config usb filel SWES lt configkt copy
36. agement by Telnet Users can use TELNET to configure the switches The default value is below M IP Address 192 168 1 254 B Subnet Mask 255 255 255 0 M Default Gateway none ia User Name admin i Password admin Follow the steps below to access the console via Telnet Step 1 Enter the Telnet IP address of the switch from the Windows Run command Run he 2 xi Tvpe the name of a program Folder document or Internet resource and Windows will open it For vou Open telnet 192 168 10 1 Cancel Browse 56 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Step 2 The Login screen will appear Use the keyboard to enter the Username and Password and then press Enter User Access Verification Username admin Password SWES gt en SWESH configure terminal Commander Groups Go Command ip address ip addr ip mask configure no boot host dhcp configure no ip default gateway configure e server ip _ Stri show boot host dhcp configure show ip address configure 57 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 show ip default gateway show ip name server show ip mode gt gt m ja se TO ol Digo e E ID 310 D o Sx m OD addr string 5 e D Q D 5 e gt D o D lt D s S Time no ntp sync day show ntp client enable show ntp client timeserver show clo
37. ck timezone show ntp sync schedule enable show ntp sync minute show ntp sync hour show ntp sync day show ntp sync month show ntp sync weekly speed auto 10 100 1000 duplex auto full half flowcontrol receive on off desired zx e Ta hace TE des TF AC Lean Jee o o o jalala s l El 3 3 ZAR 2 2 2 9 2 Z2 e o o o60 un 2 gt 8 8 8 8 8 8 3 18 5 35 SS 3 o n OM oio AIL DO Q 05 5 0 0 0 0 3 Q lt lt lt lt lt 5 3 3 3 3 4 0 0 3 Q2 3 3 2 Q lS o kO 01010613 13131615 12191319105 5 23 2 3 0 0 3 EVE lal O O N DIX I gt 3 Q9 c 3 3 9 13 13 S F S lela RIS o 3 l2elo llo lp gt 3 3 Ee x AE NE ME lk EECH Elo E ba lt 7 D o 3 3 0 3 o9 E o 0 3 KE Q lo D lt D LE 3 a olo D o 2 c D 3 O 5 rmp D configure configure configure configure configure configure configure configure configure configure configure configure configure Configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure configure interface interface interface OT 00 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 name string shutdown no speed no duplex no name no shutdown show speed show duplex show name show duplex show link rx show
38. e s IP address and set the interval time for a power recycle timing the particular PoE port Power over Ethernet PoE KEEPALIVE IP Address Li TEST FESTERE Se E mm mm Figure 5 16 PoE Ping Alarm Interface 20 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 4 3 PoE Schedule For energy saving or power recycle powered devices the PoE managed switch s PoE schedule interface allows users to appoint any date and time to enable or disable PoE functions for each POE port Power over Ethernet PoE SCHEDULE Porti Monday Enable Start time hour End time hour Tuesday Enable Start time hour End time hour Wednesday Enable Start time hour End time hour Thursday Enable Start time hour or Figure 5 17 PoE Schedule Interface 5 5 ERPS In any industrial automation application designing the redundant ring network paths that can protect networks from unexpected failovers is extremely important in mission critical networks that need to provide uninterrupted services In practice several loop protection methods are implemented to ensure that the network functions normally without loops and recovers as soon as possible when a point of failure occurs The most popular ones are RSTP 802 1w and MSTP 802 1s For industrial applications the ERPS G 8032 are highly recommended since they can achieve faster recovery time than any STP protocol Due to different
39. edium and 3 High Click the Apply button to save changes Figure 5 49 ToS Mapping Terms amp Value Description 41 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 10 Port Mirroring Enable or disable the mirroring feature When enabled a copy of matched frames will be mirrored to the destination port specified in the port mirroring interface Port Mirroring PORT MIRRORING Port Mirror Mode Go To Interface Monitor Direction Source Port Porti Port2 Port 3 Port4 Port5 Port6 Figure 5 50 Port Mirroring Configuration Interface Port Mirror Mode Enable Port Mirroring function by checking the box Users can use the dropdown box to choose the Go To Interface mu destination port as Port to mirror on feature Users can select the monitor direction from the dropdown box by Tx Rx or TX RX Users can decide any particular port as the source port s Source Port l will require port mirroring Click the Apply button to save changes Figure 5 51 Port Mirroring Terms amp Value Description Monitor Direction 42 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 11 SNMP Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers workstations routers switches and hubs etc on an IP network SNMP enables network administrators to manage network performance find and
40. erface configure 5 lo AE 2 3 Oa 3 13 _ 3 D Q gd OD c dE OD 5 1 E ou O Oo g o 2 OD configure configure D D gt o O lolo D IO D O o o ooo zy IED 13 gt 2 22 D o o ale lea ia FS US o oO DIO HIE O Q Oo lt configure D D O s Q Q ct 3 D O Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 SU no spanning tree mst instance ID priority no spanning tree cost no spanning tree port priority no spanning tree link type no spanning tree auto edge no spanning tree admin edge no spanning tree admin edge no spanning tree stp LI gt O LI o 3 WE Q SP D D EO o do o D DI 5 XI 5 O Ag D D D 3 o e o e DI D O D L e o e Q 5 i O d GC O AA DI S 5 DAK Q isi O kam i 3 spanning tree mst instance ID cost cost value spanning tree mst instance ID port priority priority STP no spanning tree mst instance ID port priority show spanning tree mst name show spanning tree mst revision configure configure configure interface interface interface interface interface interface interface configure configure configure configure configure interface interface interface interface interface interface configure configure configure configure configure interface interface configure configure configure int
41. erface interface configure configure 6 N Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 configure s D D 3 o e 5 o t S 2 O o mE S 2 O O lt D 2 configure a 2 D D o t 5 o e jab 2 O D 9 O 3 O 3 t lt interface D D 3 o ech 2 o D 2 O D O O O o o o o o 2 O2 O o O O O O zs o o o o O Io oo O Q jab jab jab 2 2 2 2 s ms 2 2 2 2 O Q Q Q interface D D 3 o o D D O D O CH O OD ee O pm ech lt configure configure D D lt lt OD D 2 em je o o 33 m er o O o O O O zz D D CS N D D 2 2 D D o o D D configure o er Di pa D 5 cb o D D lt 2 ret LI 3 ec Ko Q e o configure configure configure configure configure configure 3 D3 O D O So 18 3 a D OD S F o o o o 5 5 a 131 3 3 3 M QOQ ue 1421 63 O ID O O 313 o low oO D A J T DIO S 9 Olgidg 2 01 3 3 Io D D D Q og US 5 N IFE jab zi9Zzo O o OD 3 5 m D gt JE O gt lo S O 9 TI D 5 Z Q gt o Z D m E D Q O em configure o e D O D lt D ret LI 3 tj OD Q Q o configure configure configure Event configure configure configure configure o
42. es a loop free network by using polling packets to detect faults When a fault occurs ERPS heals itself by sending traffic over a protected reverse path less than 50ms and recover quickly to forward traffic Because of this fault detection mechanism the network broadcast storm problem could be avoided as well 5 5 1 ERPS Status Below Figure 5 18 shows the network redundancy ring status with the Ethernet Ring Protection Switch ERPS protocol ERPS Status ERPS Status Protocol Ring ID Ring State Normal Mode State INITIAL STATE Channel 1000 Revertiwe Enable Figure 5 18 Redundant Ring Network ERPS Status 22 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 5 2 ERPS Configuration Below Figure 5 19 shows the ERPS configuration interface ERPS Configuration ERPS Confiqure Protocol Enable Y Ring Port 0 Port a Role Owner Ring Port 1 Port Role Normal Ring ID Channel smb Revertive a Figure 5 19 ERPS Configuration Interface Value Description Enable or Disable ERPS protocol ERPS ring port 0 can be mapped to port 1 port 6 Ring Port 0 l Do not set the same as Ring port 1 Ring Port 1 ERPS ring port 0 can be mapped to port 1 port 6 Do not set the same as Ring port 0 Set the ERPS role as Owner Neighbor or Normal Owner In charge of blocking one side of RPL link It will prevent the packet flow f
43. ex half 10 full 10 half mode Support symmetric and asymmetric mode to avoid packet loss when Flow Control congestion occurred Apply Click the Apply button to save changes Dp Click to undo any changes made locally and revert to previously saved values Figure 5 13 Port Configuration Description 5 4PoE Power over Ethernet LMP 0501 series is one of Antaira s industrial POE managed switches that has four built in IEEE802 3at complaint ports and each PoE port supports PoE output power up to a maximum of 30W per port It is also backward compatible with IEEE 802 af to support any standard PoE powered devices PD 5 4 1 PoE Configuration POE Configuration PoE PORT Status Mode Consumption Figure 5 14 PoE Port Configuration Interface 19 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Value Description PoE port number Any PoE port will automatically detect any powered device PD that is connected and it will display the situation Users can use the dropdown box to enable or disable any PoE port function oet the PoE power output limit value The maximum value must less Consumption than 30 0W Apply Click the Apply button to save changes Figure 5 15 PoE Port Configuration Description 5 4 2 Ping Alarm The PoE ping alarm function is using the ping command to turn on or off any PoE power output port Users can insert any particular powered devic
44. figure the RPL owner and neighbor node the ERPS could still work well under the mechanism by blocking one of the ring ports in the ERPS ring topology Blocked port NIU Normal Node Port 1 Node Port 2 Port 2 Port 1 Bess Node Port 1 Port 2 Port 1 gegen Node Port 1 Port 2 Figure 5 28 Non Configured Architecture 29 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Caution Before enabling any ERPS protocols on any of the Ring Nodes please DO NOT connect all the switches to form a loop ring network just yet There should be at least one ring port left unplugged until all nodes in the topology are ready As shown in Figure 5 28 the ERPS is blocked at one of the ring node ports The blocked port is chosen by an election mechanism that is decided by the MAC address Due to the unique MAC address the ERPS will just choose the biggest MAC as the blocking node However the user is still required to enable the RRPS protocol and assign a dedicated port number for each uplink port under Ring Port 0 and 1 but there is no requirement to setting the role Figure 5 29 below shows the configurations as a reference After the configurations press the Apply button on the bottom right corner to save the settings Note The port number within Ring Port 0 and Ring Port 1 cannot be duplicated ERPS Configuration ERPS Configure Protocol Enable Ring Port 0 Port Role Normal
45. for network redundancy E Network Management gt Web Ul based management SNMP v1 v2 Serial Console gt Qos traffic classification QoS Cos bandwidth control for Ingress and Egress broadcast storm control Diffserv gt TEEE802 1q VLAN port based VLAN support gt IGMP snooping v1 v2 IGMP filtering throttling IGMP query up to 256 group gt Supports RMON MIB II port mirroring event syslog DNS NTP SNTP SSH SSL TFTP E Advanced PoE Ports Management auto ping check gt gt Auto powered device PD detection Auto reset cycle power to unresponsive PD Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 gt PoE ports weekly power scheduling m Port Configuration gt Status statistics mirroring rate limiting event syslog m Event Handling gt Event notification by Email Cold Warm Start Power Failure Authentication SNMP trap and Fault Alarm Relay Output Software Upgrade via TFTP and HTTP Configuration Backup USB Port 1 3 Product Hardware Features B System Interface and Performance e All RJ 45 ports support Auto MDI MDI X Function e Embedded 4 10 100Tx PSE 30W Port RJ45 Ports and 1 100Fx SC ST fiber ports with multi mode 2Km or single mode 30Km e Store and forward switching architecture e 8K MAC address table e Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC B Power Input e DC 48 55V redundant with a 6 pin removal terminal block e One
46. iguration backup the switch configuration setting to their local PC or server Users can click the Choose File button to select the Upload Configuration saved configuration file from local PC or server then click the Upload the settings to the switch USB Management Fill in the folder and filename and click the button for Backup If the folder or filename does not exist the Save Running Config to USB l system will generate it automatically Ex file1 folder file2 Fill in the folder and filename and click the button for Backup If the folder or filename does not exist the Save Startup Config to USB system will generate it automatically Ex file1 folder file2 Fill in the folder and filename and click the button for Upload If the folder or filename does not exist the Upload Config from USB l system will return an error If it succeeds the system will reboot Ex file1 folder file2 Figure 5 71 Backup amp Restore Setting Terms amp Value Description 5 15 3 Auto Load amp Backup USB Auto Load and Backup Auto Load and Backup USB Auto Load USB Auto Backup Figure 5 72 USB Auto Load and Backup Setting Interface 92 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Select USB Auto Load it can auto load the startup file from the USB to the Switch And the file name is switch MAC ADDRESS cfg if the file doesn t exist it will find switch USB Auto
47. iteria and receives preferential treatments Traffic Prioritization includes three modes port base 802 1p COS and TOS DSCP By using the traffic prioritization function users can classify the traffic into four classes for differential network applications All of Antaira s industrial managed switches support the four priority queues 5 9 1 QoS Classification Qos Classification os Classification Queue Scheduling Weighted T Trust Mode Port 1 d Port 3 Oy 0 al Di T 4 4 Port 3 Port 4 Port 5 Port amp Default Cos Port 1 Port 3 Port 3 Port 4 Port 5 Port 6 Figure 5 44 QoS Classification Interface 39 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Terms Queue Scheduling Trust Mode Default Cost Apply Value Description Users can set it as Weighted or Strict Weighted Mode An 8 4 2 1 weighting is applied to each round robin priority queue Strict Mode It gives egress queues with higher priority to be transmitted first before lower priority queues are serviced User can select the trust mode with either DSCP or Cos When DSCP is selected only trusted DSCP Differentiated Services Code Point values are mapped to a specific QoS class and drop precedence level DPL Frames with untrusted DSCP values are treated as non IP frames CoS Class Of Service is well known as 802 1p t describes that the output prio
48. l managed switches Users can download the latest firmware from Antaira s website and store it within their local PC server or USB drive Upgrade FIRMWARE UPGRADE Choose File No file chosen USB FIRMWARE UPGRADE Image Figure 5 66 Firmware Upgrade Interface 49 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Users can click the Choose File button to select the latest FIRMWARE UPGRADE firmware from the local PC or Server then click the Upgrade button to have the switch be updated USB FIRMWARE Fill in the folder and filename and click the Upgrade UPGRADE button If the folder or filename does not exist the system will return an error If it succeeds the system will reboot Ex file1 folder file2 Figure 5 66 Firmware Upgrade Setting Terms amp Value Description 5 14 2 Reboot Users can click the Apply button under the Reboot interface to reboot the switch Reboot Reboots the aperating system of your device 5 14 3 Default Figure 5 67 Switch Reboot Interface Users can reset the switch to Factory Default by clicking the Apply button under the default interface Reset Factory Default Reset factory default of your device Figure 5 68 Reset Factory Default Interface 5 15 Configuration Under the Configuration section users can save all the settings that have been configured backed up and stored to a local PC Server o
49. link tx lt 3 13192109 o DO O nm DM D oiol9i22 Ti zy O 5 3 e e O IO JO O O 32 ja 3 3 lt sz 5 M a SS SS ue Cp o KO 121305 35 3 m se S Qm oix A od E use O 0 3 5 Zo ooo 2 S lo lL IV IES O gigo 2 O lt 13 VDO DIES OD S L ase O16 O ola E G Se O em A C 5 D Q D O c e S num group portlist 2 Q en O E oO Tet O j D IO D E p eL gt olo o D 2 lolo ololo a oz A SHE Ola SEN Q I Oo oll a D O 3 l a j Q C gt e CD O O Dm 2 o e O 2 O O m D t 2 D lt O D T Sep D t lt O o no name no member no vlan mode no vlan group VLAN 2 2 O O O o o o SERE e e rmt O O O g g 2 O O O O O O 31313 Sera o lols SKS Q D interface interface interface interface interface interface interface interface interface interface interface interface interface interface interface interface interface interface interface interface vian vian configure configure interface interface interface interface vian vian configure configure interface interface interface C1 CO Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 show name show member show vlan mode show vlan group show switchport pvid show switchport filter enable disable aps channel channel ID revertive
50. lo SSS NS NSBS O MS SE A ee but ias O O6 E EE EE 16191313 1313 Ne 25 LE a dee lee EN A e EI 2 2 2 2 2 2 2 5 5 5 2 8 ala Ga I TC IS IL Sa l Sa IBDIDID F O DO iaa Sia lolo llo la la 312123 1313 313 ta to DIS gt S alala jo jojojo DEE AT D 513 9 42 3 IS x Q O la S Diigo Gr OIC w DSE ERES lt 5 zi 318 512 E 3 O 120 E o lt GG TI IS E 5 Og Zes alz o Le 14095 Si 3 5 C O configure n To o O Oo amp 5 13 2 2 SS Q Q E D D D 3 D O D configure rt D D 3 O Q D m o e D 3 o 5 configure o O QD 2 as m D D O O t lt EE O e E lt e Cc o configure cop A D D h O E D A Q ct 3 D gm O E D A a 3 o o o O Q Q e gt 2 2 2 Q Q configure A D D 3 D o ct 5 D 3 D o 3 L configure interface o o D 2 5 O c D D Q O N t 5 2 Q O N mE lt D c ALA o U o CH DI 5 E dE 5 O E n D O 3 Q gt lt o amp O Pe 3 DI Gale o Q o spanning tree port priority port priority interface point to multiple interface pir D D 5 2 lt o D T O gt e c O LO O 3 e interface o W o O 2 gt eo c D o E E ira D Q Q o spanning tree admin edge on interface int
51. manufacturers who provide their own proprietary redundant ring protocol and users facing inconvenient situations with compatible issues when they are planning to design or upgrade their ring network for future proof Antaira is proud to introduce and implement the Ethernet Ring Protection Switching ERPS protocol as a standard ring solution for network redundancy with all new industrial managed Ethernet switches In order to provide users with the flexibility and compatibility when there are any existing switches that contains the standard ERPS protocol 21 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Ethernet Ring Protection Switching ERPS defined in ITU T G8032 implements a protection switching mechanism for Ethernet traffic in a ring topology By performing the ERPS function potential loops in a network can be avoided by blocking traffic to flow to the ring protection link RPL to protect the entire Ethernet ring In a network with ring topology that runs ERPS only one switch is assigned as an owner that is responsible for blocking traffic in RPL so as to avoid loops The switch adjacent to the RPL owner is called the RPL neighbor node that is responsible for blocking its end of the RPL under normal condition Other participating switches adjacent to the RPL owner or neighbor in a ring are members or RPL next neighbor nodes to this topology and normally forward receive traffic ERPS like STP provid
52. me The first character must be an alpha character And the first or last character must not be a minus sign The allowed string length is O to 255 Factory Default 5 Port Managed PoE Ethernet Switch Users can assign any new name label to describe this PoE Managed Switch Factory Default Blank Users can use this field to insert the physical location of this switch e g telephone closet 3rd floor The maximum allowed string length is 0 to 255 and the allowed content is the ASCII characters from 32 to 126 Factory Default Blank Users can insert this field with the administrator of this switch together with information on how to contact this person The maximum allowed string length is O to 255 and the allowed content is the ASCII characters from 32 to 126 Figure 5 4 Switch Settings Description 5 2 2 Admin amp Password Below describes how to confi login gure the system user name and password for the web console Admin Password ADMINISTRATIVE ACCOUNT Figure 5 5 Administrative Account 15 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 New Password Users can assign a new password and the maximum string length allowed is 0 to 31 characters Re type the new password Click Apply to save changes Figure 5 6 Admin amp Password Description 5 2 3 IP Setting Configure the managed switch s IP setting information IP Setting IP CONFIGURATION DHC
53. oduct described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual The information contained is subject to change without prior notice Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
54. onfig syslog mode po remote local usb SWES config H syslog mode all SHES config syslog mode usb SWESCconfig gt i Select USB or ALL it can auto save the waning file to USB And the file name is message 6 CLl enable gt configure terminal gt usb auto load enable 7 CLI enable gt configure terminal gt usb auto load enable 70 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 7 Technical Specifications Table 7 1 has the technical specifications for Antaira s LMP 0501 series 5 port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port and 1 100Fx SC ST IEEE 802 3 10Base T 10Mbit s Ethernet IEEE 802 3u 100Base Tx 100Base Fx Fast Ethernet IEEE 802 3x Flow Control for Full Duplex IEEE 8023 af Power over Ethernet IEEE 802 3at Power over Ethernet Plus Enhanced IEEE 802 1d STP Spanning Tree Protocol TER IEEE 802 1w RSTP Rapid Spanning Tree Protocol IEEE 802 1s MTP Multiple Spanning Tree Protocol ITU TG 8032 Y 1344 ERPS Ethernet Ring Protection Switch IEEE 802 1q Virtual LANs VLAN IEEE 802 1x Port based Network Control Authentication IEEE 802 1ad Stacked VLAN Q in Q IEEE 802 1p QoS CoS Protocol for Traffic Prioritization P CSMA CD IGMPv1 v2 SNMPv1 v2 TFTP SNTP SMTP RA HP Syslog Data Process Store and Forward 14 880 pps for 10Base T Ethernet port 148 800 pps for 100Base TX Fast Ethernet port Packet Buffer 1Mbits MAC Table 8K Jumbo
55. ounted tightly on the rail To remove the industrial Ethernet switch from the rail do the opposite from the above steps Figure 3 2 Figure 3 3 Insert the Switch on the DIN Rail Stable the Switch on DIN Rail 10 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 3 2 Wall Mounting Follow the steps below to mount the industrial Ethernet switch using the wall mounting bracket as shown below in Figure 3 4 li 2 9 4 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail Bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket 18 0 71 Figure 3 5 Wall Mounting Bracket Dimensions 11 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 4 Hardware Installation 4 1 Installation Steps This section will explain how to install Antaira s LMP 0501 series 5 port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port RJ45 ports and 1 100Fx SC ST fiber port Installation Steps 1 2 Unpack
56. pe to tx queue queue qos map dscp priority type to tx queue queue qos trust cos dscp qos default cos cos default value no qos queue schedule no qos map cos priority type no qos map dscp priority type no qos trust show qos queue schedule show qos map cos priority type show qos map dscp priority type show qos trust show qos default cos gt O 3 o O O o 09 5 o D O SS C O O 3 3 D O D 3 D o D O O 2 a e ES oO o 2 O O o 2 e fe c D lt 5 RV x D o O O Q S Q d c le Ie e 13 13 131313 eloo lo loo 3 lo loa loa lo lo O mD gt ES gt gt 510 ee re V j ac cm o 9g 9O O0 O O O gt gt gt D D lo o o A A a 5 sz ilolsisio a la e LAE MES OD D D EN Es I S Le Leg e BipCioej lo z V9 0 5 voco o D Io IO lt 5 o c Dliol lol O 2 6 T OD oco z2 OQ gt oO rr Es F amp KE O 53 2 D o Oo O gt o ct D O O 5 OD o O O o 2 O o c D lt 3 RV x gt gt gt ololo alala 3133 lolo o 09 o D D gt oOo lolo ol o o o O O gt DO gt alala spo C 9 ajo D E gt 33 T olo o olole kun DI m O 316 D E lt 2 D configure configure configure configure configure configure configure configure configure configure configure interface interf
57. r a USB storage device through the built in USB port Users can use the USB port feature to execute the Auto Load function to boot the switch s 50 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 configuration that has been saved within the USB storage device or users can utilize this function to Auto Load the configuration to other switches and those switches would require the same configuration settings Users can keep the USB storage device plugged in with the switch to enable the USB Auto Backup function to allow the switch s configuration settings to backup to the USB storage device whenever users makes and save configuration settings 5 15 1 Save Users can click the Save button under the SAVE CONFIGURATION interface once all the settings had been configured Save SAVE CONFIGURATION Save Configuration Figure 5 69 Save Setting Interface 5 15 2 Backup amp Store Backup amp Restore CONFIGURATION MANAGEMENT Backup Configuration Upload Configuration Choose File No file chosen USB MANAGEMENT Save Running Config To USB 11 11 111 11 111 Save Startup Config To USE 1 1 1 1 111 Upload Config From USB Ee Figure 5 70 Backup amp Restore Setting Interface 51 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 CONFIGURATION MANAGEMNET By clicking the Backup button it allows the user to Backup Conf
58. raight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD Transmit Data minus TD Receive Data minus RD Table 2 3 Ethernet Signal Pin Outs The following figures show the cabling schematics for straight through and crossover Switch Router or PC Swi teh Switch 3 TD 3 TD g3 RD 3 TD 6 TD 6 RD 6 TD amp TD RD 4 1 TOH RD RD 2 RD 2 RD 2 RD 2 TD Figure 2 4 Straight through Cable SchematiQ 6 Figure 2 5 Crossover Cable Schematic Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 2 6 Fiber Port Antaira s LMP 0501 series provide model options to help support one major fiber optical port and models for either an SC or ST type fiber connector The multi mode up to 2 km 1310 nm in 50 125 um 62 5 125 um The single mode in 30km 1310 nm in 9 125 um When connecting the fiber port to another fiber port please follow the figure below to connect accordingly The wrong connection will cause the port to NOT work normally SC Connector Cable Wiring SC to SC
59. riority 0 240 be blocked by priority in LAN The value of priority must be the multiple of 16 Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other switch i e It is served by a point to point LAN segment Admin P2P or it can be connected to two or more switches i e It is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True means P2P enabling False means P2P disabling The port is directly connected to end stations and it Auto Edge mE cannot create bridging loop in the network To configure 32 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 cc the port as an edge port set the port to True The port includes the STP mathematic calculation Admin Non STP True is not including STP mathematic calculation False is including the STP mathematic calculation Click the Apply button to save changes Figure 5 32 RSTP Configuration Terms 8 Value Description MSTP Multiple Spanning Tree Protocol It is defined in IEEE 802 1s it can map a group of VLAN s into a single Multiple Spanning Tree instance MSTI In fact the Spanning Tree Protocol is applied separately for a set of VLAN s instead of the whole network Different root switches and different STP parameters can be individually configured for each
60. rity of a packet is determined by user priority field in 802 1Q VLAN tag The priority value is supported Oto7COS value map to 4 priority queues Highest SecHigh SecLow and Lowest User can set each port s priority queue from O to 7 by clicking from dropdown box of which 0 is the Highest and 7 is the lowest Click the Apply button to save changes Figure 5 45 QoS Classification Terms amp Value Description 5 9 2 CoS Mapping Figure 5 46 CoS Mapping Interface 40 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Users can assign each port a CoS value from 0 to 7 According to the IEEE 802 1p users can define each CoS Cos Value 0 7 m l value in 4 priority queues from Low to Normal Medium and High Click the Apply button to save changes Figure 5 47 QoS Mapping Terms amp Value Description 5 9 3 ToS Mapping ToS is an acronym for Type of Service It is implemented as the IPv4 ToS priority control It is fully decoded to determine the priority from the 6 bit ToS field in the IP header The most significant 6 bits of the ToS field are fully decoded into 64 possibilities and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority control bit 0 63 wes v Joxco ss Mec Y 0xC4 49 Figure 5 48 ToS Mapping Interface User can assign each ToS value with 4 priority queues form O Low to 1 Normal 2 M
61. rnet Switches LMP 0501 Series User Manual V1 0 5 6 4 MSTI Configuration 34 SNR QAM 1O VLAN m 36 5 7 1 802 1Q VLAN settings 36 5 7 2 802 1Q VLAN Settings 37 Os GIVI SO e St RU Ein id 37 5 94 IGMP SENOS india 38 5 8 2 IGMP Snooping Status Table 38 5 9 QoS Traffic Prioritization 39 59019065 ClASSIICAT ON ama eid 39 592005 MAPPING scisco sense 40 59 35 TOS MAD DING usanne imr EY RR t ees 41 5 10 POMON O Hae 42 SJ ME SIE EEE AG 43 E ecyinnnveesaaniaent aes eeyiane 43 5 11 2 SNMP Trap Setting 44 5 12 System Warning sisa 44 5121 Syslog SEMINO Hva 45 5 12 29yStem Event HOG ae 46 512 ON NN 46 5 12 4 Event Selection 47 dl FR NT 48 SIMAO Taplin aA 48 5 13 1 MAC Address Table 48 5 13 2 MAC Table Configuration 49 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 14 Maintenance eese 49 SF AG 916 1 E 49 A en ee ete eee reer ne 50 eee OC GIT ET P 50 Balo ONU O TE publi 50 SALE gt UU MT 51 5 15 2 Backup 8 Groe 51 5 15 3 Auto Load amp Backup 52 cod OC O E 53 6 Command Line Interface Management 53 6 1 About CLI Management
62. rom its blocked port Neighbor In charge of blocking one side of RPL link It will prevent the packet flow from its blocked port Normal Besides Owner and Neighbor node the rest of nodes are defined as Normal node All node roles have the ability to block the port if the link attach to the port is failed and disconnected ERPS ring ID ranges from 1 to 239 Ring ID distinguishes different Ring topology 23 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 ERPS Channel ID ranges from 1 to 4094 It s a channel to send PDUs of ERPS Revertive Set to Revertive yes or Non revertive no The revertive mode works only under scenario at the RPL Owner node Revertive While the revertive mode is set the RPL link will be blocked in 5 minutes after recovery form link failure situation Otherwise it will remain unchanged of the blocking state That is the failed link port will block permanently until the next event happen Non Revertive The failed ring link the port attached to it will remain blocked even the situation is eliminated Apply Click the Apply button to save changes Figure 5 20 ERPS Configuration Terms amp Description 5 5 3 Before Configuring ERPS Before configuring ERPS the rapid spanning tree protocol RSTP or multiple spanning tree protocol is required to be disabled because only one protocol can be exclusively running within a switch Below are the steps
63. s local time or click Sync with Local Time browser button to have the local time setup automatically Users can use the dropdown box to setup the switch s location Select Your Time Zone time zone Enable NTP Client Enable or disable the NTP function to get the time from the SNTP server Time Server User can define the time server info Click the Apply button to save changes Figure 5 10 System Time Settings Description 17 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 3 Port Management 5 3 1 Port Status The following information provides the current port status Status Speed Duplex Rx Byte Tx Byte PoE Figure 5 11 Port Status Interface 5 3 2 Port Configuration Users can assign or insert a value label for each port under each Port Name box enable or disable each port function state the speed duplex of each port and enable or disable the flow control of the port Port Configuration PORT Flow het n Statur 3 uple EE MGA AA aaa Figure 5 12 Port Configuration Interface Value Description It shows each port status Up for link active and Down for link inactive User can create or insert a value or label for each port s identification Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 Status Enable or disable a port User can set the bandwidth of each port as auto negotiation 100 full 100 Speed Dupl
64. se a specific port from the dropdown box next to ring port 0 and set it as the Owner node by clicking the dropdown box next to Role which is below ring port 0 At this point Port 1 has been chosen as an example otep 2 Choose a specific port from the dropdown box next to ring port 1 then set it as Normal from the dropdown box next to Role which is located below ring port 1 At this point Port 2 has been chosen as an example Note The port number of Ring Port 0 and Ring Port 1 cannot be duplicated After the configurations press the Apply button on the right bottom corner to save the setting ERPS Configuration ERPS Configure Protocol Enable Ring Port 0 Dong Role Owner Ring Port 1 Role Ring ID Channel k k H x a a 4 4 a Revertive lt m L Figure 5 25 HPL Owner Node Setup Example Please note when the revertive mode is set to Yes the ring will recover the same information as shown in Figure 5 24 after the ring state will go from ABNORMAL to NORMAL within 5 minutes Otherwise the blocked port will remain permanently blocked unless users reconfigure it 27 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 RPL Neighbor Node Users should choose a second managed switch that is adjacent to the first managed switch and set it up as the RPL neighbor node For configuration users should login to the second managed switch s ERP
65. solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 11 1 SNMP Agent SHMP Asent SNMP Enable SNMP d Read Only Community Read and Write Community Figure 5 52 SNMP Agent Setup Interface Enable SNMP Enable SNMP function by check the box Read only Community User can release the SNMP to public for read only E Click Apply button to save changes pipi Figure 5 53 SNMP Agent Interface Terms amp Value Description 43 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 11 2 SNMP Trap Setting Trap Setting SNMP Enable SNMP Trap Trap Destination IF Community Figure 5 54 SNMP Trap Setting Enable SNMP Trap Enable theSNMP Trap function by checking the box Users could insert the Server IP address as Trap Trap Destination IP Destination IP info Community Users can release the SNMP to public for read only Click the Apply button to save changes Figure 5 55 SNMP Trap Settings Terms amp Value Description 5 12 System Warning oystem warning function is very important for managing a switch Users can manage the switch by Syslog System Event Log and Email Server setup for Advanced Notice in any event type Event Type Selection and Fault Alarm setting By setting up all these sys
66. tem warning features users will receive the in advanced warning message through email whenever any event occurs It definitely increases the flexibility and capability for the users to monitor the remote site network and device statuses 44 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 12 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Syslog Setting SYSLOG SYSLOG Mode Disable T SYSLOG Server IP Address Local Only Remote Only USB Only E Figure 5 56 Syslog Setting Interface Terms Value Description Disable Disable SYSLOG Local Only Log to local system Remote Only Log to a remote SYSLOG server USB Only Log and store SYSLOG data and warning file to USB storage device through built in USB Port SYSLOG Mode and the file name is message All Log to all local server USB port and remote SYSLOG server at the same time Notice that there is one log in local server or USB port If USB presented it will log to USB storage Otherwise it logs to local server SYSLOG Server IP Address Insert remote SYSLOG server IP address cnl Click the Apply button to save changes Figure 5 57 SYSLOG Setting Terms 8 Value Description 45 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 12 2System Event Log Users can view and display the system event log by clicking the
67. the industrial Ethernet switch from the original packing box Check if the DIN Rail bracket is screwed on the industrial Ethernet switch e If the DIN Rail is not screwed on the industrial Ethernet switch please refer to the DIN Rail Mounting section for DIN Rail installation e f you want to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section Power on the industrial Ethernet switch and then the power LED light will turn on e If you need help on how to wire power please refer to the Wiring the Power Inputs section e Please refer to the LED Indicators section for LED light indication Prepare the twisted pair straight through category 5 cable for Ethernet connection Insert one side of the RJ 45 cable into switch s Ethernet port and on the other side into the networking device s Ethernet port e g switch PC or server The Ethernet port s RJ 45 LED on the industrial Ethernet switch will turn on when the cable is connected to the networking device e Please refer to the LED Indicators section for LED light indication When all connections are set and the LED lights all show normal the installation is complete 12 Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 5 Web Management 5 1 Web Console Configuration This section introduces the
68. tor as the picture shows below in Figure 2 16 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and forma normally open circuit An application example for the fault alarm contact is shown below in Figure 2 9 NL PWR1 Sg PWR2 24V de 1A Resistance Insert the wires into the fault alarm contact No 3 amp 4 Figure 2 9 Wiring the Fault Alarm Contact Note e The wire gauge for the terminal block should range between 12 24AWG Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 3 Mounting Installation Rear Panel of the switch 3 1 DIN Rail Mounting The DIN Rail is pre installed on the industrial Ethernet switch from the factory If the DIN Rail is not on the industrial Ethernet switch please see Figure 3 1 to learn how to install the DIN Rail on the switch Figure 3 1 The Rear Side of the Switch and DIN Rail Bracket Follow the steps below to learn how to hang the industrial Ethernet switch 1 Use the screws to install the DIN Rail bracket on the rear side of the industrial Ethernet switch To remove the DIN Rail bracket do the opposite from step 1 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 Check if the bracket is m
69. user programmable alarm relay contact B Operating Temperature e Standard operating temperature models 10 C to 70 C e Extended operating temperature models 40 C to 75 C M Case Installation e P 30 protection metal housing e Installation in pollution degree to environment e DIN Rail and wall mount design 1 4 Package Contents W 1 LMP 0501 series 5 Port industrial POE managed Ethernet switch with 4 10 100Tx 30W Port RJ45 ports and 1 100Fx SC ST fiber ports 1 Product CD 2 W all mounting brackets and screws 1 RJ45 to DB9 Serial Console cable 1 DC cable 18 AWG 8 DC jack 5 5x2 1mm Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 1 5 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual Antaira Industrial Ethernet Switches LMP 0501 Series User Manual V1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 0501 series 5 port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port and 1 100Fx SC ST fiber port W x D x H is 46mm x 99mm x 142mm CAR qgqo ogegeovo0cv coe 090000 NO 9 O 9 9 90 90 99 9 0 9D PONG NY 900P 9 O0DOYODD P0009 9 00 00 900090 029 GJ GF O 0 0
Download Pdf Manuals
Related Search
Related Contents
1 - Brother BALONMANO Firmware and Boot Code Release Notes for Emulex OneConnect available for Whirlpool WFW9600TC00 User's Manual Lennox Hearth BT5010 User's Manual Hyundai IT HQL260WR User's Manual Copyright © All rights reserved.
Failed to retrieve file