AMP Oil Free Manual

image

Contents

1. 27 Technology AMP Oil Free Manual AMP 50 8 TC AMP 50 6 D AMP 50 24 Silentaire Technology 8614 Veterans Memorial Dr Houston TX 77088 800 972 7668 Fax 832 327 0669 www silentaire com techsupport silentaire com Thank you and congratulations on the purchase of your AMP Oil Free Compressor Silentaire Technology is the leader in portable quiet air compressors and we are here to help you throughout the lifetime of your new air compressor AMP Compressors are built to the highest quality standards which produce excellent efficiency If you use it properly and maintain it according to this manual it will perform to your fullest satis faction for many years to come Please read this manual carefully and follow the instructions it will guarantee you trouble free operation A Installation 1 After taking your Silentaire AMP Oil Free Compressor out of its packaging please check it carefully for any damages from shipping 2 Install the compressor on a flat surface in a suitably sized dry room with good ventilation where the temperature is not likely to rise above 94 Degrees Fahren heit 35 Centigrade 3 Dispose of the Packing Material in compliance with the regulations in the coun try or state where the compressor is installed Safety 1 Do not use the Silentaire AMP Oil Free Compressor for purposes other than those for which they have been designed 2 Do not modify or repair the compressor while it i
2. cates that you might have an air leak in your system or that your compressor is too small for your application 7 To turn off your compressor simply turn the knob on the Pressure Switch Fig 1 to the OFF position counterclockwise If the electrical power is inter rupted while the compressor is in operation and it fails to restart after the power comes back on turn the knob on the Pressure Switch to the OFF position this will release any pressure in the line and enable the compressor to restart again Notice The Safety Relief Valve is a standard feature on your compressor This valve opens automatically if the tank pressure goes beyond a safe level Do not attempt to adjust or remove this device D Maintenance Your AMP Oil Free Compressor has a few parts that need your attention for proper maintenance 1 Air Intake Filter must be kept clean for easy airflow to the Fig A compressor dirty or clogged filters must be replaced or cleaned thoroughly in a detergent soap and water solution replacing or cleaning under normal conditions is necessary every 3 6 months Never operate the compressor without the Air Intake Filter in place 2 Moisture Trap If you use your compressor properly the Moisture Trap Fig B built into the Filter Regulator will trap the moisture and dirt particles before releasing air into the line Periodic checks for moisture should be done on a routine basis bv looking at the clear bo
3. er F1 4 F1 4 25mm long AMPO15 Fitting L 1 4 1 4 21 Fitting Reduction M1 4 F1 8 Pump Compressor 110V 60Hz 5000 110 AMPO22 Check Valve AMP AMP Pump Compressor AMP 220V 50Hz 5000 220 AMPO23 Plastic Hose OD 6mm AMP Pump Compressor AMP 110V 60Hz 8000 110 AMPO24 Air Hose AMP F1 4 Fspecial AMP Pump Compressor AMP 220V 50Hz 8000 220
4. fitting and hose connec tors with a soap water solution for leaks bubbles and repair the leaks tighten connec tions or replace seals e g Head Pressure Release Check Valve is not sealing Drain tank pressure remove the plug of the Valve is leaking while the check valve and clean the seat if necessary re ia place the seal and remount all the components compressor is idle Part AMPO22 Head Pressure Release Head Pressure Release Replace Pressure Release Valve Valve is leaking while the Valve is defective compressor is running The compressor keeps Pressure Switch is defec Replace Pressure Switch running and the Safety tive Release Valve Part AMPO20 is releasing air The compressor does not Air leaks at fitting con Check for air leaks and repair them If you think reach the shut off pres nections or defective com Mere might be a defect in the compressor head contact Tech Support sure and overheats pressor head gasket or valve The compressor is noisy Broken Rubber Mounts or Replace the Rubber Mounts If metallic noise and produces a metallic defective bearing in com 4925 go away contact Tech Support sound pressor pump If your AMP Oil Free Compressor has a different symptom of a fault from the above troubleshooting chart list please contact Tech Support Tech Support is available Mon Fri 8 5 Central Time F Limited Warranty The warranty is for the original purchaser We
5. is completed and re ceived by us within 30 days of the date of the original purchase lt 44 44 44 474 AMP 50 8 TC ar AMPOO8 _ SS SSS Z m ca SS SSS SSS AMPO10 PE IIS 5 SSS xv gt D 7 yA NS SS 7 z a B lt gt D AY XX N AMPO1 1 d er g AMPOO7 WEES RGIS 0 NO NS AMPOZA m AMPO1 SP BAMPOO1 A T2CSI2 7 00 AMP 50 6 D P AMPOAO S TOP 039 AMPO43 AMPO41 AMPO4467 AMP042 AMPOO7 AMPO24 MPO18 757 E EE lt AMPO2 AMPO36 MPO17 AMPO23 7 Z Z gt Z 1422 00 9 LS Z2Z AMP 50 24 AMP0138 PL ir AMPO15 AMP011 ANI IR LI AMP024 Ste S SON 3 y D Na D 4 lt 1 I f lt KU h 4 e lt Z SS gt 0 TA A i Qu PO 3 M 2 q ik q N 0 lt AMP026 AMP Oil Free Parts List AMPOO1 Bolt M5x10mm AMPO26 Drain Cock AMP AMPOO2 Foot Rubber AMP 5003 AMP 5015 AMPO27 AMPOO7 Fitting L M1 4 M special AMPO10 Holder for Capacitor AMP 5003 AMP AMP035 5015 8000 AMPO13 Spacer M1 4 M1 4 85mm long AMPO14 Spac
6. rchased AMP compressor the unit should be grounded for your own safety in the event of a short it reduces the risk of an electric shock If you need an extension cord for you to operate the unit only use a heavy duty extension cord no longer than 20 feet or 6 0 m no household cord it might cause a loss of power and damage the electrical components Notice Tampering with the Power Cord or Grounding Terminal will void warranty 5 Turn the knob on the automatic ON OFF Pressure Switch Fig 1 to the AUTO position until it stops The Pressure Switch has been set to automatically start and stop the compressor at the preset pressure levels Leave it in the AUTO position until you want to turn off your compressor Note Never remove or repair the ON OFF switch while the compressor is con nected to the electric outlet Fig 2 6 After the compressor has run for a complete cycle to pressurize the tank and then shut off set the desired pressure with the Filter Regulator Fig 2 Simply lift the knob up until it unlocks then turn it clockwise to increase the pressure until the Pressure Gauge on the Filter Regulator shows the desired pressure To reduce the pressure also lift the knob on the Filter Regulator and turn it coun terclockwise Note Never open the Filter Regulator completely it would ruin your compressor in a Short period of time If you notice that your compressor pump is running more than 50 of the time this indi
7. s connected to the electric current or while the tank is still pressurized Ao TE RISK OF ELECTRIC SHOCK CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The bolt of lightning indicates un insulated material within your unit may cause an electrical shock For the safety of everyone please do not remove product covering The exclamation point calls attention to features for which you should read the enclosed literature closely to prevent operating and maintenance problems WARNING TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE C Operating Instructions 1 Check that the automatic OFF AUTO Pressure Switch Fig 1 is in the OFF position 2 The Silentaire AMP Oil Free Air Compressors are available in the following different models AMP 50 8 TC AMP 50 6 D and AMP 50 24 All these models are available in either 110V 60Hz 220V 60Hz or 220V 50Hz Check to see if the outlet of your electric supply corresponds to your compressor model 3 Connect the equipment for your application to the outgoing 1 4 male fitting on the Filter Regulator Fig 1 To keep the connecting fitting from leaking air you should always apply Teflon Tape to the threads of the fitting 4 Plug the cord into a properly installed and grounded outlet of electric supply corresponding to your pu
8. will repair or replace without charge any part of a compressor we find to be defective in factory material or workmanship within one year of purchase Warranty services are provided at our service facility located in Houston at the address shown below You must pay all Shipping and handling charges for your compressor Any material that is shipped to Silentaire Technology without prior approval will not be accepted This warranty does not cover your compressor if the Serial Number or Model Number is removed or illegible Or if your compressor is a damaged in trans port by fire corrosion moisture or any occurrences beyond our control b sub jected to negligence or misuse or c operated or maintained contrary to our in structions We will not be liable for damage to persons or property commercial loss or incidental or consequential damage due to a defective compressor All implied warranties including warranty of merchantability or fitness are lim ited to the duration of this written warranty However some states do not allow the exclusion or limitation of incidental or consequential damages Therefore the above limitation may not apply to you If you wish to obtain warranty service or further information concerning this warranty contact Silentaire Technology 8614 Veterans Memorial Houston Texas 77088 Phone 832 327 9378 FAX 832 327 0669 This warranty will be void unless the attached warranty registration card
9. wl at the bottom side of the Filter Regulator Moisture can be removed by pressing up the valve core at the bottom of the bowl If it should be necessarv to remove the clear bowl for cleaning vou should be careful that the clear bowl doesn t contain anv air under pressure at the moment vou unscrew the clear bowl 3 Pressure Tank Check the Pressure Tank daily for water inside Fig C Unplug The compressor and release all compressed air from the Tank by opening the Drain Plug Tilt the unit towards the plug to allow the water to drain Air Hose and other accessories should also be drained ona regular basis S m j I A 7 ig 7 BI u Fig B Fig 1 E Troubleshooting For any kind of repair or replacement only use original spare parts They are available at every authorized service center Imitation spare parts may irrepara bly damage your compressor When asking for information or services always specify the Model Type and Serial Number of our compressor This information is on a label on your compressor Symptom Cause Remedy Compressor will not start No Power Check outlet voltage fuse and circuit breaker Wait 30 minutes and try starting the compressor Thermal overload protec again or press button from the top of the pres tor has tripped sure switch Pressure drops in the tank Air leak at connectors Pressurize the tank to maximum pressure switch it off and control all the