Precision Component Analyzers- 6430B & 6440B

image

Contents

1. Electronics PRECISION COMPONENT ANALYZER WAYNE KERR Hide Setup if e Auto Ronda Slow ALC off CALIBRATE Precision Component Analyzers 6430B amp 6440B Fast automatic capacitor testing High measurement accuracy on dissipation factor Fast measurement speed 0 02 basic measurement accuracy Comprehensive measurement functions Graphical sweep on all measurement functions Characterize components to 3 MHz Large LCD display and intuitive user interface Unbeatable price The 6430B and 6440B Precision Component Analyzers provide thorough and accurate testing of any passive component to high resolution In particular for capacitor manufacturers the instruments provide capabilities for both fast automatic production testing and complete design characterisation Users include designers of passive components manufacturing test designing and testing materials as well as circuit designers who are evaluating component characteristics The resonant frequency can be automatically calculated for any component together with its equivalent series or parallel circuit at that frequency Both instruments are designed for high performance testing of components with a basic accuracy of 0 02 at a low price 6430B is the entry level instrument covering to 500 kHz whilst the fully featured 6440B covers to 3 MHz www waynekerrtest com To evaluate a component performance at high speed over a specif
2. Common 0 V Bin outputs 0 to 5 V nominal with gt 10 mA current sink capability Option B2 isolated Common 24 V input Outputs 0 to 24 V with gt 10 mA current source capability Measurement connections 4 front panel BNC sockets 4 wire Kelvin measurements with screen at ground potential General Power requirements 115 V or 230 V AC 10 selectable 150 VA Max Mains frequency 50 60 Hz Mains fuse rating 230 V operation 1A T type 115 V operation 2A T type sales waynekerr info Electronics Display High contrast monochrome LCD module 320 x 240 with back lighting Visible area 115 x 86 mm Viewing angle 45 Printer output Centronics parallel printer port Remote control Conforms with GPIB IEEE 488 2 and SCPI 1992 0 Mechanical Height 150 mm 5 9 Width 440 mm 17 37 Depth 525 mm 20 5 Weight 11 kg 24 25 Ib Environmental conditions Temperature Range Storage 40 C to 70 C Operating 0 C to 40 C Full Accuracy 15 C to 35 C Relative humidity Up to 80 non condensing Altitude Up to 2000m Installation category Il in accordance with IEC664 Pollution degree 2 mainly non conductive This equipment is intended for indoor use only in a non explosive and non corrosive atmosphere Safety Complies with the requirements of EN61010 1 EMC Complies with EN61326 for emissions and immunity UK Wayne Kerr Electronics Vinnetrow Business Park Vinnetrow Road Runcto
3. Printing results and external control Whether it s a single parameter table of results from multi frequency mode or a logarithmic graph of component performance the 6430B and 6440B will output the results directly to a printer The GPIB interface is used to control the instrument and read back measured values for quality control or for archiving purposes Output lines are also available to control a bin handler interface Component tolerance levels may be pre set and stored A 25 way D connector mounted on the rear panel gives easy access for connection to external component handling equipment Fast automatic multi frequency production testing of capacitors The 6430B and 6440B deliver fast automatic testing of capacitors in a production environment The user is able to select measurements from any of the instruments range and perform up to eight different tests on each component Tolerance bins can be selected for each of the tests The instrument selects the overall bin after completing all the tests The measured results can be output over the GPIB or to a printer The test sequence is triggered by external input GPIB or the front panel Once the test sequence is complete the bin is selected and the measured data is made available on the GPIB This process takes place at very high speed allowing a dual frequency test to be completed in approximately 180 ms Pass Fail data in statistical form is available to the user and can
4. 0 02 Q 0 05 Q 1 Q D 0 0002 1 D2 www waynekerrtest com Technical data sheet Rdc 0 1 Accuracy varies with compe and frequency range measurement speed Modes of operatio Measurement Selection of any measuret Single level function menu keys Single and repetitive measurements displaying major and minor terms t parameter and test condition ontrolled by keyboard and soft Deviation As measurement mode but relative or percentage deviation from nominal value displayed for major or minor term Multi frequency Measurement parameters and test conditions set using measurement mode Up to 8 frequencies with absolute or percentage limits on major term Pass Fail indication Multi frequency capacitor optional Test condition set using measurement mode Up to 8 frequencies with different measurement parameters Binning result in up to 10 bins with percentage limits on major term and absolute on minor Fast mode up to twice the speed of standard multi frequency mode Analysis mode optional 6430B Measurements parameters and test conditions set using measurement mode Graphical sweep vs frequency or level with selection of start step size units and linear log Binning optional Measurement parameters and test conditions set using measurement mode 10 bins with absolute and percentage limits Up to 99 sets of limits may be saved 25 way D type interface connector Option B1 non isolated
5. amp 6440B Measurement parameters Any of the following parameters can be measured and displayed Inductance L impedance Z DC resistance Rdc and capacitance C Series or Parallel Equivalent Circuit C R C D C Q L R L Q Series equivalent circuit only X R X D X Q Parallel equivalent circuit only C G B G B D B Q Polar Form Z Phase Angle Y Phase Angle Test conditions Frequency range 6430B 20 Hz to 500 kHz gt 1000 steps Accuracy of set frequency 0 005 gt 1500 steps with analysis option fitted Frequency range 6440B 20 Hz to 3 MHz gt 1800 steps Accuracy of set frequency 0 005 Pre set frequencies 20 25 30 40 50 60 80 100 120 150 repeats for each decade Drive level Rdc 100 mV or 1 V with 100 source resistance Drive level AC measurements Open circuit voltage 1 mV to 10 V rms Signal source impedance 50 Q Automatic Level Control ALC maintains constant voltage or current at DUT DC bias voltage internal 2 V with rapid charge capacitor bias DC bias voltage external External supply of up to 60 V may be connected via rear panel Measurement speeds Four selectable speeds for all measurement functions Up to 20 measurements per second for test frequencies 2100 Hz Measurement ranges R Z 0 01 mO to gt 2 GO G Y1nSto gt 2kS L 0 1 nH to gt 2 kH CifFto gt 1F D 0 00001 to gt 1000 Q 0 00001 to gt 1000 Rdc 0 1 mQ to gt 10 MO Basic accuracy L C 0 05 R
6. be viewed on the LCD display printed to a local printer or exported over the GPIB Excellent performance and unbeatable price As the market leader with over 50 years experience of developing component analyzers you would expect Wayne Kerr to provide the best performance in the industry However what you might not also expect is that Wayne Kerr is able to offer high performance and accuracy at very competitive prices www waynekerrtest com Technical data sheet Protection against charged capacitors High precision measuring instruments can be sensitive to charged capacitors and if connected can lead to costly repairs and unacceptable downtime Wayne Kerr Electronics have identified this problem and developed a solution that protects the test equipment from charged capacitors In this event the protection unit blows fuses which can be easily and cheaply replaced whilst the test equipment remains unharmed and continues to provide reliable accurate performance The protection unit will protect the test equipment from up to 25 Joules of charged energy Accurate component analysis to 500 kHz 6430B or 3 MHz 6440B is simplified by many accessories which includes Overload Protection Unit 1 1100 IHOUCTANCE WS FREQUENCY FUNCTION SH bk 148k LEWEL 1 008 U BIA SPEED SLOW ALC COT RETURM Inductance plotted against frequency sales waynekerr info Technical specifications precision component analyzers 6430B
7. ied range of frequencies multi frequency mode is used In this mode the operator decides which parameter is to be measured and at what frequencies The 6430B and 6440B does the rest creating an easy to read table on the large LCD display Each test can have a simple Pass Fail display Measurement parameters e Impedance Z Phase Angle Inductance L Capacitance C DC Resistance Rdc AC Resistance Rac Quality Factor Q Dissipation Factor D Admittance Y Conductance G Reactance X Susceptance B Graphical sweep on all measurement functions up to 3 MHz To characterize a component graphically the user can select any of the available measurement functions and create a graph of the parameter value against frequency or AC drive level The user is also able to toggle between the major and minor term for example impedance and phase angle Either linear or logarithmic scales can be selected sales waynekerr info Electronics Following the first sweep the user can use the FIT key which automatically scales the vertical axis to provide the optimum display for the device under test DUT A marker is also displayed which can be positioned at any point on the graph using the navigation keys The MAX and MIN keys position the marker at the peak or trough of the graph The marker position is displayed at the bottom of the screen showing the vertical axis value its minor term and the frequency or drive level
8. m the description and specification in this publication www waynekerrtest com sales waynekerr info GMS0904A
9. n Chichester West Sussex PO20 1QH UK Tel 44 1243 792200 Fax 44 1243 792201 data sheet Order codes Description Order code 6430B Precision Component Analyzer 1J6430B 20 Hz to 500 kHz 6440B Precision Component Analyzer 1J6440B 20 Hz to 3 MHz Both models supplied with User manual 2m AC power cable Kelvin clips 1EVA40100 6440B supplied with 2 x transfer standard capacitors Options for 6430B B1 Bin handler cannot be fitted with B2 B2 Bin handler opto coupled cannot be fitted with B1 IC Multi frequency capacitor function IE Analysis function standard on 6440B Options for 6440B B1 Bin handler cannot be fitted with B2 B2 Bin handler opto coupled cannot be fitted with B1 IC Multi frequency capacitor function Optional accessories for 6430B amp 6440B Description Order code Overload Protection Unit 25 Joules 1J1100 Kelvin Lead large jaw 1EVA40180 Kelvin Lead fine jaw 1EVA40100 4 Terminal Lead Set 1EV1505 BNC 4 Term Comp Fixture 1EV1005 BNC 4 Term Comp Fixture gt 500 kHz 1EV1006 SMD Probe Lead 1EV1905A SMD Tweezers 1EVA40120 Operating Maintenance Manual QH model no Certificate of Calibration with results 1JCALRES USA Wayne Kerr Electronics 165L New Boston Street Woburn MA 01801 6201 USA Tel 1 781 938 8390 Sales 800 933 9319 Fax 1 781 933 9523 Wayne Kerr s policy is one of continuous development and consequently the product may vary in detail fro

Download Pdf Manuals

image

Related Search

Related Contents

Samsung E1230 Korisničko uputstvo  EVGA 04G-P4-2649-KR NVIDIA GeForce GT 640 4GB graphics card  OASE 57616 Installation Guide  E-03 ターボイレーサ取扱説明書  GCSTGS5011 Central de vapor  Kensington KeyFolio  ART-SP1 Scaler /Polisher Combo Unit Instruction  INSONORISATION DES RIVERAINS DE L`AÉROPORT  Installation Manual - Green Energy Needs    