IO900 User Manual v1.03

image

Contents

1. g S x 8 3 by 2 gt 1B 2A 2B Discrete OUT1 OUT2 1A 1B 2A 2B OOOO OO Supressor Power Supply 120VAC 5A Max Bentek Systems Ltd Version V1 03 for SCADALink 10900 BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALIink 10900 10900 Transceiver General Range 600 to 1000 feet 180 to 305m in plant obstructed 4 5 miles 6 8km LOS with Omni antenna 20 miles 82 km LOS with Yagi antenna One 1 4 20mA analog input 16 bit 125 ohms impedance Two 2 discrete inputs 5 36VDC Outputs One 1 4 20mA analog output 16 bit short circuit protected Two 2 discrete outputs dry contact NO contact rating 120VAC 2A 12VDC 2A 24VDC2A Current loop 0 2 of full scale 77 F 25 C Primary Power ee es urge Protection ower Consumption Transceiver requency ransmit Power RX Sensitivity nit ID Antenna Connector Antenna Impedance Environmental Humidity emperature ize Weight nclosure Agency Approvals CC SC ee a ee eed ees ee ee aa FCC Rules and Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Changes or modifications not expressly approved by BENTEK SYS
2. AO4 4 20mA Analog Output Module 4 Ch ISOL BENTEK SYSTEMS LTD warrants to the original purchaser that the BENTEK products are free from defects in materials and workmanship under normal use and service for a period of ONE YEAR parts EXLUDING SWITCHES CRYSTALS OR PARTS SUBJECT TO UNAUTHORIZED REPAIR OR MODIFICATION and labor from the date of delivery as evidenced by a copy of the receipt BENTEK s entire liability and your exclusive remedy shall be at BENTEK s option either the a repair or b the replacement of the BENTEK product which is returned within the warranty period to BENTEK freight collect by a BENTEK APPROVED carrier with a copy of the purchase receipt and with the return authorization of BENTEK If failure has resulted from accident abuse or misapplication BENTEK shall have no responsibilty to repair or replace the product under warranty In no event shall BENTEK be responsible for incidental or consequential damage caused by defects in its products whether such damage occurs or is discovered before or after replacement or repair and whether or not such damage is caused by the negligence of BENTEK SYSTEMS LTD Bentek Systems Ltd Version V1 03 for SCADALink IO900
3. 20 110 100 90 80 70 60 This represents a 90dB signal loss and typically indicates that the radio has i 7 K Signal Loss dB 20dB fade margin left until loss of link It is recommended that the radios be set up with no less than 20dB margin Bentek Systems Ltd Version V1 03 for SCADALink lO900 BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALIink 10900 Expansion I O Modules Analog Input Output Wiring Current Floating Current Source 4 20mA Device abe pie laes OOOO 4 20mA Loop IN2 External Voltage Source Pa STATUS Q bP g 3 5 8 ha 8 3 AI4 D 20mA Loop IN3 Floating Al4 Expansion Analog Input Module Bentek Systems Ltd a Analog Output 4 20mA DIP Switch Settings Fault Maintain Off Last State B 2 N w a By removing the housing of the AO4 module the end user may select between Fault Off or Maintain Last State for each of the four analog outputs of the AO4 Module OOO Om O P 20mA Loop OUT 1 GND P 4 20mA Loop OUT 2 STATUS Q yurTVavoS woo yuljepeos MMM AO4 D 20mA Loop OUT 3 P GND 4 20mA Loop OUT 4 P GND SOO SLOLOre AO4 Expansion Analog Output Mod
4. BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALink lO900 Modular Wireless I O System User Manual Version V1 3 for SCADALink 10900 BENTEK SYSTEMS LTD 315 3750 46 Ave S E Calgary AB Canada T2B OL1 Ph 403 243 5135 Fax 403 243 5165 email sales scadalink com web www scadalink com BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALIink 10900 The SCADALIink 10900 is a Modular Wireless I O System that allow license free bi directional transmission of digital and analog process signals at distances of up to 20 miles The 10900 System is a simple to use modular system that allows addition of up to 8 I O Expansion Modules to the base 10900 Controller which has 1 Al 1 AO 2 DI and 2 DO points License Free 900MHz 20 Mile Range Secure Factory Set RF Configuration 12 30VDC Operation Class Div Il DIN Rail Mounted Modules Modular Expansion to 8 I O Modules Modules 10900 Controller 1 Al 1 AO 2 DI 2 DO Al4 Module 4 Pt 4 20ma Input Module AO4 Module 4 Pt 4 20ma Output Module DI8 Module 8 Pt Digital Input Module DO8 Module 8 Pt Digital Output Module Typical Application 1AO ee e 1AO 2D0 2D0 I O is Mirrored Up to 20 Miles 1 O 900 with 1 I O 900 with 1 AO Al 1DO Module 1DIModule 1Al 4 Al 1Al Spi 8 DO 2D 4AO gD Bentek Systems Ltd Version V1 03 for SCADALink IO900 BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALink 10900 10900 Transceiver Analog and Discr
5. TEMS LTD will void the user s authority to operate the equipment This product is intended for fixed installation applications In order to comply with FCC ISC adopted RF exposure requirements installation of this transmitter system s antennas must be performed in a manner that will provide at least 6 foot 2m clearance from the front radiating aperture to any user or member of the public FCC Part 15 247 ISC RSS 210 Approval IA9FHOEM900 Approval 1338104550A CSA C amp US Class 1 Div 2 Groups A B C D Bentek Systems Ltd Version V1 03 for SCADALink 10900 BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALink 10900 Configuring I O Module Addresses 5 5 n 4 6 4 V N 7 Vz Vk N 7 3_ _7 3_ _7 3 T 3 _7 3 7 27 TNs 27 Ss 2f Ni 1 Module Address Selection Switch Each pair of I O modules such as the Al4 and the AO4 must share a unique module address Once a module address has been assigned to a pair of I O modules that module address may not be used on any other pair of I O modules or the same radio pair Available addresses are numbers 1 through 8 If module addresses conflict or are improperly set within a connected group an indication will be given by the STATUS LED see section below w wi vows Y Ip 4 5 Fi P The IO900 Transceivers are designed to operate as matched pairs and are factory programmed Manual address configuration is not required for the tran
6. ete Input Wiring Current Sala O C O Current a OOO gt Sie Tere B GND t QO 2 Q Q A B anD pwr RF Link Power Floating IN Signal Floating 4 20mA STATUS e Rss 10900 Discrete IN1 IN2 o A p 2 b gt gt PA S x 8 3 woo yujepeos mmm ANUITVAVIS rssi 10900 Discrete 1B 2A 2B IN1 IN2 Discrete 1A 1B 2A T1 Discrete T1 OUT2 1A 1B 2A 2B STOLOTe OLLLDES Discrete Discrete Input 1 Input 2 2 Wire 4 20mA Device 3 Wire 4 20mA Device Bentek Systems Ltd Version V1 03 for SCADALink 10900 BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALIink 10900 10900 Transceiver Analog and Discrete Output Wiring Link Status Indicator RF Link Output X The Link Status contact on the 10900 is Normally Open and closes when the radio establishes an 4 N RF Link It can be used to switch either a STATUS light or a FAULT indicator Selecting State of Outputs upon Loss of RF Link Analog The default state upon loss of RF signal for the Analog and Discrete Outputs is MAINTAIN LAST Output STATE They may be wired in series with the RF 4 20mA ey Link contact to provide a FAULT OFF when RF Link is terminated IN STATUS Q Rss 10900 Discrete IN2
7. sceiver units Status LED s Power LED Power LED indicates presence of power to the device It is ON when power is present and OFF when there is no power Status LED When flashing rapidly it indicates an Internal Error or a Module Type Mismatch A Module Type Mismatch occurs when the Module Address selection for two different modules i e one 1 discrete module and one 1 analog module are set to the same address or two 2 pairs of modules are sharing the same address When Status LED is ON steady Module Address settings are OK RF LED Flashes once every two seconds when there is no RF Link Flashes rapidly when signal strength is marginal see RSSI Table ON steady indicates an exceptionally strong RF Link Most systems will flash occasionally indicating the presence of intermittent interference in the area Discrete OFF means that the discrete input or output is Open Input Output ON means that the discrete input or output is Closed RSSI Troubleshooting RSSI vs DC Voltage RSSI Received Signal Strength Indicator is measured using a DC Voltmeter between the test point and power supply ground Test point is 4 00 accessed by inserting positive meter probe into the RSSI hole on the face of 3 00 the IO900 S 3 2 00 The following RSSI table may be used to test the Receive Signal Strength of S 1 00 the IO900 l 0 00 The ideal voltage that should be read from the RSSI test point is 2 5VDC 1
8. ule Version V1 03 for SCADALink 10900 BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALink 10900 Expansion I O Modules Discrete Input Output Wiring Liquid Level Fault Contact DIP Switch Settings Fault Maintain T i Off Last State 2 Pressure Fault Contact O O O O r S 5 5 Discrete STATUS JA 1A 1B 2A 2B T uriya YOS Temperature N1 N2 Discrete Fault Contact 3B 4A 4B N 3 IN4 Discrete STATUS By removing the housing of the DO8 OQ module the end user may select DO8 between Fault Off or Maintain Discrete IN6 Last State for each of the eight D discrete outputs of the DO8 Module bp Supressor yurivavos DI8 Discrete N5 N6 Solid State 5B 6A 6B Switch Discrete 7 N8 7B Power Supply Power Supply Ss OOO ane 5A 100VAC DC O O O Max DI8 Expansion Discrete Input Module DO8 Expansion Discrete Output Module Bentek Systems Ltd Version V1 03 for SCADALink 10900 BENTEK SYSTEMS LTD SCADA and Telemetry Solutions SCADALink 10900 Specifications O Expansion Modules DI8 Discrete Input Module Low Volt DO8 Discrete Output Module 8 Ch Relay 10mA 24VDC outputs OFF 6 0mA 24VDC outputs ON Al4 4 20mA Analog Input Module 4 Ch