Home
Product Information Sheet 1
Contents
1. EA e IQ BER 120 180 240 TA CICLO AUTOMATICO CYCLE AUTOMATIQUE Fm 15 ON mu 180 300 420 DOR 23 AUTOMATIC CYCLE 1 ULM 25 SELBSTT TIGER 1 4 mmm 20 oN DES 20 lavaggio lavage washing wasch risciacquo rincage rinse sp lung 43 36 34 351 6 al 11 26 Termometri Thermome tres Thermometers Thermometer PT850 ek on 2 zx lt lt lt ZG PT1500 ek Cod 0300828 OOO B o m 32 Cod 0502001 PT850 ek il Cod 0502010 PT1500 ek lamber HE2020 com au a LEGENDA SCHEMA ELETTRICO PT L P PT 850ek PT1500ek LP6ek LP8ek LP31ek LP38ek LEGENDE SCHEMA ELECTRIQUE WIRING DIAGRAM LEGE
2. 13 20 2 5 steam 4 8 2 5 6 38 10 6 steam Inlet cable P Connection to the electric box The electrical safety of this equipment is only assured if it is connected as follows THE MACHINE SHALL BE It is necessary to connect the equipment to EES an effective ground installation as GROUND CLAMP specified by the electrical safety regulations in force The manufacturer declines any Chack that this basic requirement is responsibility for any damages complied with and in case of doubt ask for a careful check of the installation by a qualified personal caused by lack of an effective ground installation CAlomber Qe A lamber HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au WATER CONNECTIONS Carefully comply with any national or regional regulations in force Water installation must have the following characteristics Temperature 55 Dynamic Pressure 2 4 bar 200 400 kPa If the dynamic pressure is lower than 2 bar it is advisable to install a Pump for pressure increase If the dynamic pressure is higher than 4 bar it is advisable to install a pressure reduction Hardness between 7 2 and 12 5 French If the hardness values are higher than those mentioned above it is advisable to install a water softener TEMPERATURES Water temperature 55 60 C Rinse temperature 80 85 C DO NOT TA
3. HE2020 com au Hospitality Equipment 2020 P L Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 POT WASHING PIS50M ek PT1500M ek CA lamber MACHINES ges Ce Ct f CEH FT 4 C g ca vf M h L4 gt e MANUAL 01 2008 HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au INTRODUCTION ENGLISH AND SAFETY NORMS INTRODUCTION The machines are Industrial pot washing machines The machine is in conformity to the European Norms 89 336 CEE for the radio noises According to EEC directive nr 23 of 19 02 1973 and the law of actuation nr 791 of 18 10 1987 our appliances are buil up according to the good technique norms in force in Italy and abroad Noise level of the machine less than 70 dB A PRELIMINARY OBSERVATION Carefully read the instructions reported in the present user manual as it gives important indications about safety of installation operation and maintenance carefully keep the present manual for further consultations the illustrations and drawings showing the machine are intended for general reference only and are not necessarily accurate in every particular the dimensions and characteristics of the machine given in this Manual are not to be considered binding and may be changed without prior notice having removed the packing material check t
4. HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au Second Section FOR THE INSTALLER UNPACKING AND DELIVERY CHECKS When the case with the machine has been received unpack it as follows Remove the upper cover and the wooden case side walls take care not to damage the machine Remove possible accessories boxes Remove the protecting cellophane Make sure that the machine has not been damaged during transport Make sure that all covers and panels have been correctly fixed and that no loosen part is present Visually inspect that all electrical components are integral TRANSPORT AND INSTALLATION lift and transport the machine insert the truck forks under the frame connected to the points indicated by the yellow adhesives applied on the machine front side See draw below draw A Before plugging the machine make sure that the supply voltage of the domestic wiring system and the water supply from water connection corresponds to the ones reported on the rating plate Installation should be carried out by qualified personnel according to the manufacturer s indications During instalation it is recommended to level the machine in order to ensure a correct operation The Manufacturer cannot assume any responsability for any damage to persons or property deriving from the non observance of the above specified norms For correct insta
5. not broken the pump is not blocked or rotates in the reverse direction onbe s QLAVA HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au DRAWBACK POSSIBLE CAUSES AND REMEDIES Tank temperature insufficient a check that the thermostat is not faulty or not calibrated b check that the temperature of the feeding water is in the range from 50 0 10 C as specified check that the thermostat is set to the right temperature and operates correctly d check that the coil of the remote switch relevant to the tank resistor is not broken this applies to electric heating machines only e check that the heater element is effective Insufficient rinsing Prior to checking the rinsing system make sure that the washing system operates correctly as a matter of fact an effective rinsing also depends on a correct washing Having ascertained that washing takes place correctly check that a the dynamic pressure of the feeding water is not less than 2 bar 200 kPa b the jets are not clogged by calcareous residuals C solenoid valve EV4 and EV5 operate correctly d the water inlet filter is not clogged e the booster is not scaled to such an extent as to limit the water flow rate Insufficient rinsing a the thermometer is broken temperature or not calibrated b the temperature of the feeding water is in range from 55 to 65 as s
6. de penomiNazioNe SCHEMA AGGANCIO MENSOLE MENSOLE GMOS PASSAGGIO MAN amp PT850 uATERALE ACCIAIO INOX ACCIAO INOX 18 10 ASI 304 AISI 304 870 paa TEAs nee TRATTAMENTI SCC M A 1009 RS DESS Ee 6959 05
7. 02 9C 134 WWW he2020 com au 926 50 la ak _ I 1890 880 MIN LD DILL IL DIOU DD DOC 1890 800 ALLACCIAMENTI BRANCHEMENTS CONNECTIONS ANSCHLUSSE ENTRATA ACQUA CALDA ARRIVEE EAU CHAUD Solo per macchine con riscaldamento a vapore D S AW INIT La Ber Seulement pour machines avec chauffage vapeur 11 2 G San DRAIN ABLAUF y Wasserdamps maschine LINEA ELETTRICA BRANCHEMENT ELECTRIQUE ENT OOV3 50H2 wen Gus s171 2 ENTRATA VAPORE ARRIVEE VAPEUR TANKS TANKEN A STEAM INLET DAMPZULAUF 0 5 2 Bar S ves ZZ E STEAM OUTLET DAMPFABLAUF o A MODELLO Aabar PT 850 ek vers Lineare scala 31 20 NOTE DATA 27 mm 27 05 10572006 700 700 176 06 Hospitality Equipment 2020 P L Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 www he2020 com au 128 5 835 PORTA LATERALE PORTE LATERAL ENTRY DOOR 21 piano di lavoro plan de travail work table SE Kee SS H sch r Kee AMA HF Ki CZ gt gt gt N N N A CAR RR AAA RN SS 2 gt o ON Q JE Y Y s H e CDU E F 4 E a AY o AH o o CLE 3 3 E gt AS AX Sez C C work2 mensole Pos N Dises ino Denominozione Denominazione Materiale Als
8. 20 com au CONNECTIONS SCHEME amp 4 BOILER Elements 1 Black 5 2 Black ER Black 4 Staples 3 4 TANK Elements 1 Black 2 Black O 3 Black 2 4 Staples 0 3 CAlomber AE HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au A LIST OF DRAWBACKS POSSIBLY OCCURRING WITH THE USE OF THE POT WASHING MACHINE THEIR CAUSES AND POSSIBLE REMEDIES DRAWBACK POSSIBLE CAUSES AND REMEDIES Lamp C does not turn on Lamp G of overload cut out devices turning ON The tank does not fill up aber AE a check that the wall mounting switch is ON and the respective fuses are not burnt b check that fuses FS1 FS2 FS3 of the transformer TR1 are not burnt a check the overload cut outs of the individual remote switches and replace those disconnected If this drawback occurs several times in the same device it is suggested to increase the current rate through the graduated cursor b check that the power supply voltage is not subject to variations in excess of 696 of the nominal value C check that the current drained by the motor does not exceed the rated values a check that pressure switch CP1 CP2 is not calibrated or out of service b check that the
9. 7 Fax 02 9637 3434 E info he2020 com au SCHEDA ELETTRONICA a FICHE ELECTRONIQUE PC BOARD ELEKTRONISCHE STEURUNG filo fil wire draht ITA FRA ENG DEU FA1 43 ELETTOPOMPA LAVAGGIO INFERIORE POMPE LAVAGE INFERIEUR LOWER WASHING PUMP UNTERER WASCHUNG PUMPE FA2 36 PRE RISCIACQUO PRE RINCAGE PRE RINSING VOR SP LUNG FA3 34 ELETTROPOMPA LAVAGGIO SUPERIORE POMPE LAV AGE SUPERIEUR UPPER WASHING PUMP OBERER WASCHUNG PUMPE FA4 35 ELETTROPOMPA RISCIACQUO POMPE RINCAGE RINSING PUMP SPULUNG PUMPE FA5 6 FASE PHASE PHASE PHASE FA6 8 NEUTRO NEUTRE NEUTRAL UNGELADEN FA7 11 LNELLO PRESSOSTATO NIVEAU PRESSOSTAT PRESSOSTAT LEV EL DRUCKWA CHTER FA8 26 RISCALDAMENTO ACQUA VASCA RECHAUFFAGE EAU TEMPERATURE THERMOSTAT TEMPERATURE THERMOSTAT FA10 32 MICRO PORTA MICRO PORTE DOOR MICRO SWITCH ENDSCHALTER FA11 31 RISCALDAMENTO BOILER CHAUFFAGE SURCHAUFFEUR THERMOCONTROL THERMOCONTROL FA10 FA11 FA15 30 SICUREZZA SURETE SECURITY HAUBE SICHEREIT FUNZIONE CICLO TABELLA SELEZIONE TABELLA SELEZIONE TEMPI DI LAVAGGIO TABELLA SELEZIONE O ro ue DA SELECTION TEMPS DE LAVAGE TEMPI DI RISCIACQUO TABLEAU SELECTION AP AUF AURGABE _ DE PRERINGAGE AUSWAHLSTAFEL F R SPULUNGSZEIT TEMPS DE RINCAGE SELECTION TABLE RINSE TIME E n Sa AUSWAHLSTAFEL SELECTION TABLE MANUAL CYCLE FUR VORSPULUNGSZEIT DIP LED1 ON LED2 ON LED1 2 ON AUSWAHLSTAFEL HANDABLAUF FUR SPULUNGSZEIT ON
10. Lower washing pump GREEN 3 z Waschpumpenmotor HE2020 com au a LEGENDA SCHEMA ELETTRICO LEGENDE SCHEMA ELECTRIQUE WIRING DIAGRAM LEGEND ELEKTROSCHALTSCHEMA PT L P PT 850ek PT1500ek LP6ek LP8ek LP31ek LP38ek M4 Elettropompa risciacquo Rinsing pump M5 Elettropompa lavaggio superiore 2 Upper wasching pump 2 M6 Elettropompa lavaggio inferiore 2 Lower wasching pump 2 FS1 FS3 Fusibili Fuses TR1 Trasformatore Transformer SL1 Selettori tempo lavaggio Selectors T1 Timer Timer FC1 FC3 Finecorsa Limit switch FC4 FC5 Finecorsa meccanico Stop micro switch EV3 Elettrovalvola carico Loading solenoid valve EV4 Elettrovalvola risciacquo Rinsing solenoid valve EV5 Elettrovalvola prerisciacquo Prerinsing solenoid valve EV6 Elettrovalvola vapore boiler Boiler steam solenoid valve EV7 Elettrovalvola vasca Tank solenoid valve EV8 Elettrovalvola livello acqua soll Water level solenoid valve RM1 RM6 Protezione termica Electric pump thermal IR1 1D1 Contatto temporizzato IR2 1D2 Time contact DD1 Dosatore di lavaggio Detergent pum oner Pompe rincage Nachsp lpumpenmotor Electropompe lavage sup 2 Waschpumpenmotor 2 Electropompe lavage inf 2 Waschpumpenmotor 2 Fusibles Sicherungen Transformateur Transformator Selecteurs temps lavage Selektor der Reinigungszeit Timer Timer Microinterrupteur Hauptschalter Fin de course End
11. MPER WITH THE THERMOSTAT CALIBRATION ATTENTION At the first test be sure the boiler is full of water make four n 4 one minute complete cycles WASHING RINSING 18 GREEN gt WATER DRAIN Reachable from the machine front side after opening the front panel to do this turn the two front screws out Arrange a discharge at floor level provided with siphon and connect to the floor drain by means of a hose provided with an adequate inclination Make sure the drain hose is not choked in any way Make sure the drain hose is resistant to a temperature of 70 C Carefully comply with any national or regional regulations in force STEAM FEEDING As far as steam feeding is concerned connect to the machine fittings indicated in the installation drawings In order to make the equipment independent from the general steam distribution network it is necessary to use gate and 1 gas on off valves This type of feeding should be supplied at a pressure ranging from 1bar 100 C to 2bar 121 C he steam used should be absolutely saturated and dry STEAM EXHAUST The condensed steam exhaust shall have an appropriate slope toward the recovery installation or a blow by pump in order to guarantee an autonomous scavenging of the condensed steam for steam machines only HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au VAPO
12. ND ELEKTROSCHALTSCHEMA IN1 Interruttore generale Int rrupteur g n ral Main switch Hauptschalter Ad 1 3 Filtri antidisturbo Filtres ante ennui Suppressors Entst rfilter CP1 CP2 Pressostato Pressostat Pressure switch Druckw chter LS1 Lampada spia di linea Lampe de ligne Main switch lamp Netzkontrollampe LS2 Lampada temperatura Lampe temp rature Temperature lamp Temperaturkontrollampe LS3 Lampada spia livello vasca e ciclo Lampe de cycle Cycle lamp Zykluskontrollampe LS4 Lampada spia termica salvamotori Lampe t moin thermiques protection Motor protection indicator lamp Kontrollampe Motorschutz ausgel st CT1 Termostato di sicurezza Thermostat de suret Security thermostat Schuizthermostat CT2 Termostato boiler Thermostat surchauffeur Boiler thermostat Boilerthermostat CT3 Termostato vasca Thermostat cuve Tank thermostat Tankthermostat CT4 Termostato di sicurezza 2 Thermostat de surete 2 Security thermostat 2 Schutzthermostat 2 CT5 Termostato boiler 2 Thermostat surchauffeur 2 Boiler thermostat 2 Boilerthermostat 2 R1 Resistenza boiler R sistance surchauffeur Boiler elements Boilerheizung R2 Resistenza vasca R sistance cuve Tank elements Tankheizung R3 Resistenza boiler 2 Resistance surchauffeur 2 Boiler elements 2 Boilerheizung 2 M2 Elettropompa lavaggio superiore Electropompe lavage sup rieur Upper washing pump Waschpumpenmotor M3 Elettropompa lavaggio inferiore Electropompe lavage inf rieur A lamber
13. UR EXHAUST During washing and rinsing cycles vapours come out of the upper chimney To convey these vapours connect with the cap as showed in the drawing p 50mm DIS FUMI LP AA aber Az ALAVA HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au TABLES FITTING PLAN mod PT850 ek E The machine is endowed with tables for baskets on request The fitting plan in on the draw N 1 w 6 15 Schraube 6 15 Corner version For corner version machines to assembly the Stop basket A as show on the draw 2 MENSP85 ek CAlomber A gt HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au TABLES FITTING PLAN a Prisoo ek amp Screw M6x15 The machine is endowed with tables for baskets on request The fitting plan in on the draw N 3 A onbe Qe QLAVA HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he20
14. d be carried out by qualified personnel according to the manufacturer s instructions this equipment should be destined to the use which it has been conceived for Any other application should be considered improper and consequently dangerous the equipment should only be used by personnel trained for its use SPECIAL SAFETY REGULATIONS adjustement and repairs must be carried out only by personnel qualified Repair carried out by unskilled personnel may be dangerous perfect washing up results as far as hygiene concerns and a correct operation of the washing machine can be assured only in case the instructions reported in the present handbook are carefully followed the machine must be only used by authorized personnel which must comply with sanitary measures do not leave the machine in environment with temperatures inferior to 0 C the machine protection degree is IP21 therefore it should not be washed with direct high pressure jets of water CN onbe 99 LAVA HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au INSTRUCTIONS FOR THE INSTALLER The following instructions are addressed to a qualified personnel the only one authorised to carry out checks and repair if any The Manufacturer declines any responsibility in the case of interventions made by a non qualified personnel 00 SS ee Er _ Col 2 lamber
15. hat all the equipment is present If there is any doubt do not use it and contact qualified personnel The packing elements plastic bags nails etc should be kept away from children because they are dangerous GENERAL SAFETY REGULATIONS THIS SAFETY CODE HAS BEEN COMPILED IN YOUR INTEREST Strict adherence to these rules will reduce the risks of injury both to yourself and to others Personnel working with this machine must adhere strictly to all statutory safety regulations as well as the specific rules listed below Failure to do so may result in personal inyury and damage to the machine DO NOT attempt to move install set up or operate this machine until you have read and fully understood this Manual If doubt persists ask your supervisor never leave tools parts or other loose material on or in the machine Before switching the equipment the equipment on make sure that the model plate data conforms to that of the electrical and water distribution network remember that even with the mains isolator in the OFF position the incoming cables are still live BEFORE starting machine o cycle after any maintenance or repair work make sure all protective are correctly installed be vigilant at all times remember that your safety and that of your fellow workers depend on you when moving or lifting the machine care must be taken to comply with all the relevant regulations governing such operations installation shoul
16. llation see draw page 13 14 Alomber Qe HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au ELECTRICAL CONNECTION In addition the equipment shall be part of mn an equipotential system the effectiveness of which should be checked according to Before connecting the machine the regulations in force check to make sure the voltage outlet of the mains is the same as The connection should be made at the the voltage specified on the data screw marked by the respective label plate of the machine located on the equipment back side E A main switch must be installed between the mains and the machine This safety measure also requires that the minimum MOD PT850 ek distance between the switch contacts is at x least 3 mm and the disconnection on all poles according to EN 60204 VDE 113 Fuses on the main switch must be 20 A The mains must be wired to be able to handle the current drawn by the machine The system must also be provided with a proper ground lead in accordance with the existings norms The electric cable must be of the following type HO7RN F MOD PT1500 ek For the right choice of the cross section area refer to the following table mod Volt total Current Cable power intensity mm kW max A PT1500 ek 400 3 12 2 5
17. overflow is in the respective position check that the overflow is in the respective position d check that the coil of the solenoid valve is not broken and that voltage is fed there to HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au DRAWBACK POSSIBLE CAUSES AND REMEDIES The tank does not stop being a check that the traps of the pressure filled upon reaching switch has no porosities and the connection the desired level pipe is not disconnected b check that the pressure switch is in good conditions and is not calibrated c check that there is no dirty in the solenoid valve This drawback can be noted because the machine continues to load water whilst the main on off switch is off Insufficient washing a check that the detergent is effective is of the type recommended for industrial pot washing machines and it is proportioned for the right concentration b check that the detergent container if installed is not empty and operates correctly C check that the jets of the washing swivels are not clogged If necessary clean them d check that the tank temperature is the specified one e one or several pumps don t operate in this case check that the overload cut out did not switch the pump in question and if necessary restore it this drawback is displayed by lamp G turning ON the coil of the respective remote swirch is
18. p 2 Upper wasching pump contactor 2 Sch tz Waschpumpenmotor 2 MT11 Contattore pompa lavaggio inferiore 2 Contacteur pompe lavage inf 2 Lower wasching pump contactor 2 och tz Waschpumpenmotor 2 MT12 Contattore di sicurezza 2 Contacteur de suret 2 Security contactor 2 och tz 2 MT13 Contattore resistenza boiler 2 Contacteur r s surchauffeur 2 Boiler elements contactor 2 och tz f r Boilerheizung 2 A konter LAVA Hospitality Equipment 2020 P L Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 www he2020 com au 1770 50 1890 1880 1080 O 800 880 MIN 1890 ee ALLACCIAMENTI BRANCHEMENTS CONNECTIONS ANSCHLUSSE Solo per macchine con riscaldamento vapore 2 ENTRATA ACQUA CALDA ARRIVEE EAU CHAUD sr 3 4 G HOT WATER INLET WARMWASSERZULAUF 50 60e Seulement pour machines avec chauffage vapeur SCARICO ACQUA EVACUATION EAU 1 1 2 G For steam machines only DRAIN ABLAUF e Wasserdamps maschine LINEA ELETTRICA BRANCHEMENT ELECTRIQUE L Eee EE DEI gz sgr ee amr 217172 ENTRATA VAPORE ARRIVEE VAPEUR TANKS TANKEN A STEAM INLET DAMPZULAUF 0 5 2 Bar 7 SCARICO CONDENSA SORTIE VAPEUR STEAM OUTLET DAMPFABLAUF 3 4 G 4 MODELLO B enslbxere PT 850 ek vers ANGOLO 1 SCALA 1 20 NOTE A GUT 277057 705 2005 CESTO 700x700 e X Unit 6 6 Tennyson Street Clyde NSW 2712 eT
19. pecified c the dynamic pressure of the feeding water does not exceed 2 bar 200 kPa onbe s HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 3737 Fax 02 9637 3434 E info he2020 com au DRAWBACK POSSIBLE CAUSES AND REMEDIES If the drawback is not due to any of the causes listed here above proceed as follows In the case of electrical heating machines 1 check that the coil of remote switch MT3 is not broken 2 check that the safety thermostat MT4 did not trigger 3 check all elements of boiler heater R1 In the case of steam heating machines 1 check that the steam inlet gate is open and is present at a pressure not less than 0 5 bar 50 kPa 2 check that the condensed steam drainage filter is not clogged 3 check that the steam solenoid valve EV7 operates correctly 4 check that the inlet steam filter is not clogged to such an extent as to prevent the normal flow rate 5 check that the condensed steam outlet pipe can freely drain by drop 6 check that the pipe coil is not scaled to such an extent as to limit heat exchange thereof The manufacturer declines any responsibility for any printing errors contained in this booklet The manufacturer also reserves the right to make any modifications to its products that don t affect the basic characteristics thereof lamber y QLAVA HE2020 com au Unit 6 6 Tennyson Street Clyde NSW 2142 Tel 02 9637 373
20. schalter Electrovanne chargement ElektrischesWassereinlaufventil Electrovanne rincage Elektrisches Sp lventil Electrovanne pr rincage Elektrisches Vorsp lventil Electrovanne vapeur surchauffeur Elektrisches Dampf Boilerventil Electrovanne cuve Elektrisches Tankventil Electrovanne niveau eau Elektrischesventil Protection thermique Motorsch tz Concact temporis Zeit Schaltshutz Doseur produit lavage Waschspulmitteldosiergerat HE2020 com au a LEGENDA SCHEMA ELETTRICO LEGENDE SCHEMA ELECTRIQUE PT LP erasoex prisocek WIRING DIAGRAM LEGEND LP6ek LP8ek LP31ek LP38ek ELEKTROSCHALTSCHEMA MT3 Contattore controllo livello Contacteur control niveau Level control contactor Schutz f r Niveaukontrolle MT4 Contattore di sicurezza Contacteur de suret Security contactor Schutz MT5 Contattore resistenza boiler Contacteur r s surchauffeur Boiler elements contactor Sch tz f r Boilerheizung MT6 Contattore resistenza vasca Contacteur r sistance cuve Tank elements contactor Schutz f r Tankheizung MT7 Contattore pompa lavaggio superiore Contacteur pompe lavage sup Upper washing pump contactor Schutz Waschpumpenmotor MT8 Contattore pompa lavaggio inferiore Contacteur pompe lavage inf Lower washing pump contactor Schutz Waschpumpenmotor MT9 Contattore pompa risciacquo Contacteur pompe rincage Rinsing pump contactor Sch tzNachsp lpumpenmotor MT10 Contattore pompa lavaggio superiore 2 Contacteur pompe lavage su