Home
PR Century Spot User Manual
Contents
1. 170170012 Bus transceiver IC 170040032 12 14 EEPROM IC Century Spot manual_Last Revision_en doc 13 14 Century Spot manual_Last Revision_en doc PR LIGHTING LTD No 571 Yingbin Road Dashi Panyu Guangzhou China Post Code 511430 TEL 86 20 8478 1888 FAX 86 20 8478 6023 P N 320040047 Last Revision 02 08 2004 14 14 Century Spot manual_Last Revision_en doc
2. RELIABILITY CENTURY SPOT PR 2002 This product manual contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference PR LIGHTING LTD Yingbin Road Dashi Panyu Guangzhou 511430 China http www pr lighting com INDEX SECTION PAGE SAFE USAGE OF THE PROJECTOR 3 STRUCTURE FITTING THE LAMP POWER SUPPLY MAINS OPERATION STAND ALONE MODE XLR CONNECTORS AND TERMINATOR MASTER SLAVE MODE CONTROLLER MODE DMX 512 OPERATION MAINTENANCE KEEPING THE PROJECTOR CLEAN TROUBLESHOOTING TECHNICAL DATA 10 ELECTRICAL DIAGRAM 11 COMPONENT ORDER CODES 12 Please note that as part of our ongoing commitment to continuous product development specifications are subject to change without notice Whilst every care is taken in the preparation of this manual we reserve the right to change specifications in the course of product improvement The publishers cannot be held responsible for the accuracy of the information herein or any consequence arising from them Please refer to our product if you find any difference between this preliminary issued manual and product Every apparatus has been tested completely and packed properly by the manufacturer Please make sure the packing and or the apparatus is in good condition before your installation and use Should there be any damage caused by transportation
3. consult your dealer and do not use the apparatus But any damage caused by improper use will not be assumed by the manufacturer and or dealer ACCESSORIES THESE ITEMS ARE PACKED TOGETHER WITH THE PROJECTOR Waterproof plug 1 PCS XLR control cable with 3 pin plug and socket 1PCS This manual 1PCS INTRODUCTION Thank you for purchasing the product Century Spot PR 2002 RA This product manual contains important information about the safe installation and use of this projector Please read and follow these instructions carefully and keep this manual in a safe place for future reference The Century Spot is an innovative projector with an elegant housing made from high quality aluminium alloy with an epoxy paint finish The Century Spot complies to CE norms and standards and uses international protocol DMX 512 The Century Spot features full CYM colour mixing with high resolution stepper motors and an independent adjustable linear mechanical dimmer 0 100 The protection against dust and liquid is very high IP 44 and guarantees perfect functions even in unfavorable weather conditions The angle of inclination of the projector head is adjustable easily from 15 to 90 It is an ideal luminaire to lighten buildings exhibitions or for artistic applications 2 14 Century Spot manual_Last Revision_en doc SAFE USAGE OF THE PROJECTOR The following points are important for safety as well as for the smoot
4. the lamp appears dim this would normally indicate that it is reaching the end of its life and it should be changed at once old lamps run to the extremity of their life may explode If the projector does not function check the fuse in the projector base It should only be replaced by fuse of the same specified value 16A 380V fast blow ceramic On the main PCB inside the projector there is also a fuse rated 4A 250V fast blow 5mmx20mm Should these be damaged call a qualified technician before replacement The projector has thermal protection device that will switch off the projector in case of overheating should this operate check that the fans are not blocked and if they are dirty clean them before switching on the projector again Check that the fans are operational Any maintenance work should only be carried out by a qualified technician KEEPING THE PROJECTOR CLEAN To ensure the reliability of the projector it should be kept clean It is recommended that the fans should be cleaned every 15 days The dichroic colour filters should also be regularly cleaned to maintain an optimum light output Do NOT use any type of solvent on dichroic colour filters Cleaning frequency depends on the environment in which the fixture operates damp smoke or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics A soft cloth and typical glass cleaning products should be used in cleaning Do not use any organic solven
5. 7 built in program Set time between scenes Y Reset enable STAND ALONE MODE Without connecting the controller when enable the function 1 the apparatus will run in stand alone mode In this mode you can set the DMX start address to any value XLR CONNECTORS AND TERMINATOR XLR CONNECTORS DMX IN DMX OUT DMX512 f 4 2 FUNCTION Q SA 1 DATA DATA Connection between controller and projector and between one projector and another must be done with 2 core screened cable with each core having at least a 0 5mm diameter Connection to and from the projector is via an XLR control cable with 3 pin plug and socket which are included with the projector The XLR s are connected as shown in the figure above Note care should be taken to ensure that none of the connections touch the body of the plug or each other The body of the plug is not connected in any way The Century Spot accepts digital control signals in standard DMX512 1990 format 5 PIN AND 3 PIN CONVERSION Century Spot uses 3 pin XLR plug socket If your controller uses 5 pin XLR plug socket you should convert 5 pin plug socket into 3 pin socket plug as shown below 3 PIN PLUG 5 PIN PLUG 3 PIN SOCKET Pin 2 Signal Pin 2 Signal Pin 2 Signal 5 PIN SOCKET Pin 1 GND SCREEN Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C Pin 3 Sig
6. Press the button RESET to reset the DMX start address and functions and the left green LED will flash one time TO SET THE DMX START ADDRESS See the panel above The digital screen will display the DMX start address Press the button DOWN you can change the start address Press the button ENTER to confirm The green LED will flash one time which means that apparatus has saved your setting The setting will be displayed when you turn on next time In stand alone mode the DMX start address could be set any value In master slave mode refer to the chapter MASTER SLAVE MODE In controller mode the address of each apparatus must be set correctly so as to be controlled respectively Refer to the chapter CONTROLLER MODE TO SET THE FUNCTION Press the button FUNC consecutively the digital screen will display turn the function code 1 9 A b Each one represents one function You can see the following table for details When you locate the function code you can press button or to display or n When the digital screen display you can save and validate it via button ENTER When the digital screen display n you can save and invalidate it via button ENTERI 5 14 Century Spot manual_Last Revision_en doc CODE OPTION FUNCTION Y Auto program enable Y Master Slave mode enable Choose 1 of
7. dards Do not connect this device to any dimmer pack Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by the plug Never pull out the plug by tugging the power cord Keep the lamp clean Do not touch the lamp glass with bare hand The lamp used in this projector is a high power discharge lamp After being switched off don t attempt to restart the projector until lamp has cooled this will require approx 15 minutes Switching the lamp on and off at short intervals will reduce the life of both the lamp and the projector Occasional breaks will prolong the life of both the lamp and the projector Never run the projector without a lamp There is no user serviceable parts inside the projector do not open the housing and never operate the projector with the covers removed Always disconnect from the mains when the device is not in use or before cleaning it or before attempting any maintenance work If you have any questions don t hesitate to consult your dealer 3 14 Century Spot manual_Last Revision_en doc STRUCTURE PROJECTOR HEAD LIPS Capes ROTATION PROJECTOR HEAD 7 PLUG OVER OF CONTROL PANEL ANDLE FITTING THE LAMP Caution For the safety reason remove the sponge between the colour filters before the 15 application of luminaire Position the p
8. h installation and performance of the unit When unpacking and before disposing of the package check there is no transportation damage before using the projector Should there be any damage caused by transportation consult your dealer and do not use the apparatus Keep the package well for your possible future transportation The projector is intended for outdoor use and is splash proof 44 Install only dry and plain locations Avoid excessive moisture The projector is not designed or intended to be mounted directly on to inflammable surfaces X The projector is only intended for installation operation and maintenance by qualified personnel The projector must be installed in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that all the cooling fans run normally and no ventilation slots are blocked Do not project the beam onto inflammable surfaces Minimum distance is 5m 9 5m Avoid direct exposure to the light from the lamp The light is harmful to the eye Do not attempt to dismantle and or modify the projector in any way Electrical connection must only be carried out by qualified personnel Before installation ensure that the voltage and frequency of power supply match the power requirements of the projector Only use the lamp with the specified type and rating It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant stan
9. nal ene o Pin 3 Signal 4 Pin 5 1 1 6 14 Century Spot manual_Last Revision_en doc DMX TERMINATOR In the Controller mode or Master Slave mode the DMX output has to be connected with a DMX terminator at the last fixture in the chain This prevents electrical noise from disturbing and corrupting the DMX control signals The DMX terminator is simply an XLR connector with a 120Q ohm resistor connected across pins 2 and 3 which is then plugged into the output socket on the last projector in the chain The connections are illustrated below DMX TERMINATOR CONNECTION Connect 120 OHM resistor across pins 2 and 3 in an XLR plug and insert into the DMX out socket on the last unit in the chain ae PIN2 MASTER SLAVE MODE Many luminaires can run synchronously by linking them with each other in the master slave mode Set the address of all luminaires to 001 Select one luminaire as the master and set the function code 1 and 2 to y Don t connect its input with an XLR control cable Set the function code 1 and 2 of the rest luminaries to Now they are slaves Connect the master s output to the first slave s input with an XLR control cable and connect the first slave s output to the second slave s input with an XLR control cable The rest may be connected in the same wa
10. our temperature 6000 K Manufacturers Rated Lamp life 500 Hours Standard DMX 512 Stand alone Master Slave and DMX Controller 6 channels 3 basic colours CYM 256 colours continuous mixing white blackout 12 35 Adjustable from 15 to 90 75 kg Linear dimming from 0 100 thermal cut off 0 10 14 Century Spot manual_Last Revision_en doc ELECTRICAL DIAGRAM Transformer Yellow Magenta Focus Cyan Dimmer Shut off Thermostat 11 14 Fuse 16A 380V Main PCB al OUTPUT Display PCB Century Spot manual_Last Revision_en doc COMPONENT ORDER CODES NAME PART NO REMARK TRANSFORMER 040010045 230 50 60Hz IGNITOR 040090004 230V 50Hz BALLAST 040070033 230V 50Hz RELAY 192010009 230V 20A FILTER 193020001 10A THERMOSTAT 1 190010035 120 15 THERMOSTAT 2 190010054 95 C 10A FAN 4 pcs 030060019 230V 19W FAN 030060042 220 50 60 2 LAMP 100050024 HMI 2500W SE CAPACITOR 4 pcs 140010018 60UF AC 370V MOTOR 030040029 17HS1013L MOTOR 030040097 17HS1013 10L 230040093 Digital PCB 170110001 Driver IC 170170039 Manostat IC 170050002 Amplifier 230040088 Main IC1 230040087 Monitor IC 230040089 Main IC2 170040002 TTLIC 170170034 Reset IC
11. rojector head facing the sky and lock it via locking knob Remove the projector head cover by loosening the 4 retaining clips Open the dichroic colour filter bracket by undoing the 2 M6 knurled screws Insert the lamp in the lamp holder and ensure PST pumping stem tip off on the lamp is at a right angle 90 to the beam path Don t touch the bulb by bare hand Close the dichroic colour filter bracket and install projector head cover Make sure that all screws and retaining clips are tightened Note The HMI series are high pressure lamps with external igniters A Care should always be taken when handling these lamps Always read the manufacturers Instructions for use enclosed with the lamp POWER SUPPLY MAINS Use the plug provided to connect the mains power to the projector paying attention to the voltage and frequency marked on the panel of the projector It is recommended that each projector be supplied separately so that they may be individually switched on and off 4 14 Century Spot manual_Last Revision_en doc OPERATION When the power is switched on the apparatus automatically starts to run the programmes of self test After finishing these the apparatus is ready for the following operation Remove the cover of the control panel You will see the panel as shown in the figure below ar Ho FUNC DOWN UP ENTER om The right red LED flashes means there is a DMX signal receiving DMX OUT
12. t e g alcohol to clean the housing of the projector TROUBLESHOOTING PROBLEM ACTION Check the fuse on the power socket Replace the lamp Make sure that the projector is correctly configured Replace or repair the DMX cable The projector only functions intermittently Make sure the fan is working and not dirty Check the lenses are not broken Remove dust or grease from the lenses Make sure the lamp is installed correctly Carefully clean the optical group lenses and the The projector doesn t work The lamp comes on but the projector doesn t respond to the controller Defective projection The projected image appears to have a halo projector components Check the optics is clean The beam appears dim Replace with a new lamp of the specified type and rating LIGHT OUTPUT 35 lux 3000 750 330 180 120 12 44500 11120 4940 2780 1780 12m 18m 3 DISTANCE 0 5 10 15m 20m 25m 12 DIAMETER 0m 01 0 2 0 03 1 4 2 5 2 35 DIAMETER 0m 3 15 6 3 9 45 12 6 157 9 14 Century Spot manual_Last Revision_en doc TECHNICAL DATA Power supply Power consumption Lamp Protocol Running mode DMX channels Colours Beam coverage Tilt angle Net weight Others 750 220 230 50 60 2 2800W OSRAM HMI 2500W SE single end Col
13. y Eventually connect the last slave s output to a DMX terminator as shown below Wii MASS a TERMINATOR 7 14 Century Spot manual_Last Revision_en doc CONTROLLER MODE DMX 512 OPERATION Century Spot adopts international standard DMX 512 protocol You may control many luminaires via controller When in controller mode the function code 1 and 2 of all luminaires should be set to n and each apparatus should have specific address to receive the signal from the controller Century Spot has 6 channels So in controller mode the address of 1 luminaire is 001 2nd 007 3 013 4 019 etc Please follow the formula address of n luminaire 6 n 1 1 Connect the controller s output to the 1 luminaire s input and connect the 1 luminaire s output to the 274 luminaire s input The rest may be connected in the same way Eventually connect the last luminaire s output to a DMX terminator as shown below DMX INPUT OUTPUT TERMINATOR CONTROLLER DMX 512 DMX CONTROL CHANNEL FUNCTIONS The Century Spot has 6 channels They are shown in the following table 4 Magenta 000 255 White to magenta continuous change 000 255 Focusing from big to small 000 249 250 255 8 14 Century Spot manual_Last Revision_en doc MAINTENANCE If the lamp becomes damaged or deformed in any way it must be replaced If the light from
Download Pdf Manuals
Related Search
Related Contents
RTD258 EN_ok=addendum - VOXX International Corporation Virtual Buss Compressors SDX207のデビューです。 ULTRA WASH ®Dishwasher Lavavajillas ULTRA WASH ® Lave Samsung 19" TV monitor koos kiire reageerimisajaga Kasutusjuhend Initiation aux langages de commandes et `a la programmation sous コイスミ学習デスク OPERATORS GUIDE RocketCRAFT™ Oocyte temporary access catwalk - SPX Cooling Technologies Copyright © All rights reserved.