Home

using the stretcher

image

Contents

1. p S 5 2 15 o 9 lt Decontaminating this page Disinfecting this page Cleaning this page Inspecting page 13 Lubricating page 13 e When using maintenance products follow the manufacturers directions and read the manufacturers material safety data sheets In the U S A contact Ferno Customer Relations to order Ferno disinfectants and cleaners page 14 WARNING Improper maintenance can cause injury Maintain the stretcher only as described in this manual 12 5 2 Decontaminating the Stretcher The stretcher is suitable for power washing When decontaminating the stretcher follow the instructions for decontamination equipment and cleaners and read the manufacturers material safety data sheets Contain and dispose of contaminants according to government guidelines Lubricate the stretcher See Lubricating the Stretcher page 13 after decontaminating it Important Using abrasive cleaning compounds or applicators on the stretcher frame can cause damage Use only nonabrasive materials to clean the stretcher 5 3 Disinfecting and Cleaning the Stretcher and Restraints DISINFECTING THE STRETCHER Wipe all surfaces with disinfectant Follow disinfectant manufacturer s directions Ferno recommends inspecting the stretcher for damage as you disinfect it CLEANING THE STRETCHER Clean all surfaces of the stretcher wit
2. O AAULuuo G 6 d i6ia dGacOGc tGDL AAG FERNOG MIR Major Incident Response Users Manual Model 108 D Stretcher March 2003 GLO m No 234 3234 00 Model 1 Disclaimer This manual contains general instructions for the use operation and care of this product The instructions are not all inclusive Safe and proper use of this product is solely at the discretion of the user Safety information is included as a service to the user All other safety measures taken by the user should be within and under consideration of applicable regulations It is recommended that training on the proper use of this product be provided before using this product in an actual situation Retain this manual for future reference Include it with the product in the event of transfer to new users Additional free copies are available upon request from Customer Relations Proprietary Notice The information disclosed in this manual is the property of Ferno Washington Inc Wilmington Ohio USA Ferno Washington Inc reserves all patent rights proprietary design rights manufacturing rights reproduction use rights and sales use rights thereto and to any article disclosed therein except to the extent those rights are expressly granted to others or where not applicable to vendor proprietary parts Copyright Ferno Washington Inc Rights Reserved Ferno Washington Inc 70 Weil Way Wilmington OH 45177 937
3. MANUAL Storage View For additional free Users Manuals contact Ferno Customer Relations at 1 800 733 3766 1 937 382 1451 or www ferno com 6 Ferno Washington Inc 234 3234 00 March 2003 Model 108 D Stretcher Using the Stretcher 4 USING THE STRETCHER 4 1 Before Placing the Stretcher in Service q Personnel who will work with the stretcher need to read this manual q Confirm that the stretcher operates properly Follow the instructions in Inspecting the Stretcher page 13 4 2 General Guidelines for Use e Using the stretcher requires a minimum of two trained operators e Operators may need help when working with heavy patients For information about placement and direction of helpers see Using Additional Help page 11 e Follow standard emergency patient handling procedures when operating the stretcher Stay with the patient at all times e Always use patient restraints Ferno Washington Inc 234 3234 00 March 2003 A WARNING An unattended patient can be injured Stay with the patient at all times A WARNING An unrestrained patient can fall off the stretcher and be injured Use restraints to secure the patient on the stretcher Using the Stretcher 4 3 Unfolding the Stretcher for Use To prepare the stretcher for use 1 Stand the stretcher upright with the handles on the floor or ground and with the stretcher legs facing the sides Unbuckle
4. Wrap the restraints around the stretcher and fasten them to secure the stretcher in the storage position Ferno Washington 234 3234 00 March 2003 Using the Stretcher Figure 5 Closing the Stretcher Stretcher in Storage Position T Figure 6 Folding the Stretcher Using the Stretcher 4 5 Using the Stretcher With a Patient Unfold and open the stretcher following the instructions on page 8 Then 1 Position the stretcher as close to the patient as possible Unfasten the two patient restraints and position the straps so they will not interfere with transferring the patient onto the stretcher Transfer the patient onto the stretcher according to approved medical procedures and following your local protocols Fasten and adjust the patient restraints Figure 7 Use additional help as needed to lift and carry heavy patients See Using Additional Help page 11 Additional restraints may be desired for some situations or patients Follow your protocols for using and attaching additional restraints 4 6 Attaching the Stretcher to an Ambulance Cot The stretcher can be attached to a Ferno Model 35 L Litter Carrier See the Model 35 L users manual for instructions on attaching the stretcher to the carrier 10 Model 108 D Stretcher Figure 7 Securing the Patient WARNING Improper attachment to a cot can cause injur
5. the restraints Unfold the stretcher by grasping the pairs of poles and pulling them away from each other Figure 1 Lay the stretcher with its bottom surface facing up so the legs are visible Open the stretcher by grasping both sides of the stretcher and pulling the poles apart Figure 2 Use your foot to push each pair of spreader bars toward the center of the stretcher Figure 3 until the spreader bars lock in the engaged position Model 108 D Stretcher Figure 1 Unfolding the Stretcher Figure 3 Engaging the Spreader Bars Ferno Washington Inc 234 3234 00 March 2003 Model 108 D Stretcher 4 4 Folding the Stretcher for Storage To fold the stretcher for storage 1 Lay the stretcher with its bottom surface facing up 2 Disengage the spreader bars by using your foot to push the spreader bars away from the center of the stretcher Figure 4 3 Closethe stretcher by pulling the poles together Figure 5 Note The stretcher hinges can catch and tear the mesh bed surface Before folding the stretcher check and make sure the mesh surface will not be caught when the stretcher is folded Important The hinges can catch and tear the mesh bed surface When folding the stretcher adjust the bed surface to ensure it will not catch on the hinges 4 Lift the stretcher at its center and fold the pairs of poles until the handle grips meet Figure 6 5
6. 1 U S A Telephone U S A and Canada 1 800 733 3766 Telephone Worldwide 1 937 382 1451 Fax United States 1 937 382 1191 Fax Outside U S A 1 937 382 6569 Intettiet orco terna www ferno com Ferno Washington Inc 08 D Stretcher 234 3234 00 March 2003 Model 108 D Stretcher TABLE OF CONTENTS Section Page 1 Safety Information ss 4 1 1 Warning eerie reines 4 1 2 Important eee ripe tret nere tne 4 1 3 Bloodborne Disease Notice 4 2 Operator Skills and Training ee 4 ENT 4 2 2 EG TRE onte terre e REGE TAI 4 3 About the Stretcher esse 5 6 3 1 Stretcher Description 5 3 2 General Specifications 5 3 3 Stretcher Components sees 6 4 Using the Stretcher ses 7 11 4 1 Before Placing the Stretcher in Service 7 4 2 General Guidelines for 7 4 3 Unfolding the Stretcher for Use 8 4 4 Folding the Stretcher for Storage 9 Section Page 4 5 Using the Stretcher With a Patient 10 4 6 Attaching the Stretcher to an Ambulance Cot 10 4 7 Using Additional Help 11 12 13 5 1 Maintenance Schedule 12 5 2 Decontamin
7. ating the Stretcher 12 5 3 Disinfecting amp Cleaning the Stretcher and 12 5 4 Inspecting the Stretcher 13 5 5 Lubricating the Stretcher 13 6 Repair Parts and Service 13 7 Limited Warranty 14 8 Ferno Customer Relations ss 14 Training Record 1 eeeeeee eese essen seen eene eene tnue 15 Maintenance Record sn 15 ILLUSTRATIONS AND DIAGRAMS Componehls 5 notre etre UR ERE Ue Pere ee SEE 6 Figure 1 Unfolding the Stretcher 8 Figure 2 Opening the Stretcher 8 Figure 3 Engaging the Spreader Bars 8 Figure 4 Disengaging the Spreader Bars 9 Figure 5 Closing the Stretcher ssssse 9 Ferno Washington 234 3234 00 March 2003 Figure 6 Folding the Stretcher eee eee eects 9 Figure 7 Securing the Patient 10 Using Additional Help 11 Murtenarce 12 Serial Number Location VV 14 3 Safety Info Skills amp Training Model 108 D Stretcher 1 SAFETY INFORMATION 1 1 Warning The following warnings appear in this manual A WARNING Untrained operators can cause injury or be injured Permit only trained personnel to operate the stretch
8. cant like WRL 191 or WD 40 6 REPAIR PARTS AND SERVICE 6 1 Parts and Service U S A and Canada To order parts or for professional stretcher repair contact EMSAR the only agent authorized by Ferno to manage service and repair Ferno products EMSAR factory trained technicians use Ferno approved parts and repair procedures EMSAR has a franchise location serving you For details phone fax or visit EMSAR s web site 800 73EMSAR Phone 937 383 1051 Fax www EMSAR com Internet 6 2 Parts and Service Outside U S A and Canada To order Ferno parts and for professional stretcher repair contact your Ferno distributor Your distributor is the only agent authorized by Ferno to manage service and repair Ferno products 6 3 Parts List Description Part Black mesh decon bed surface 031 3944 Handle grips set Of 4 090 0210 384 D storage case 90 org 031 1610 Black end caps set 4 090 5801 Ferno Washington 234 3234 00 March 2003 EMSAR SERVICE AND gegen A WARNING Improper parts and service can cause injury Use only Ferno parts and Ferno approved service on the stretcher A WARNING Modifying the stretcher can cause injury and damage Use the stretcher only as designed by Ferno 13 Warranty Customer Relations Model 108 D Stretcher 7 LIMITED WARRANTY Li
9. e 1 800 733 3766 Telephone tette 1 937 382 1451 p 1 937 382 1191 nte He Loci ete eeepc te et www ferno com Outside the U S A and Canada for assistance with the stretcher please contact your Ferno distributor or Ferno Customer Relations below Telephone Worldwide 1 937 382 1451 Fax Outside U S A 1 937 382 6569 Please have the serial number of your Ferno stretcher nternet Lee nec pert tiroteo www ferno com available when calling Ferno Customer Relations and include it in all written communications 14 Ferno Washington Inc 234 3234 00 March 2003 Model 108 D Stretcher TRAINING RECORD Date Name Training Method MAINTENANCE RECORD Maintenance Performed O Ferno Washington Inc 234 3234 00 March 2003 15
10. er Improper use of the stretcher can cause injury Use the stretcher only for the purpose described in this manual An unattended patient can be injured Stay with the patient at all times An unrestrained patient can fall off the stretcher and be injured Use restraints to secure the patient on the stretcher Improper attachment to a cot can cause injury Follow the attachment instructions in the 35 L users manual Always check to make sure the stretcher is securely attached to the cot Helpers can cause injury or be injured Maintain control of the stretcher and direct all helpers Improper maintenance can cause injury Maintain the stretcher only as described in this manual A WARNING Improper parts and service can cause injury Use only Ferno parts and Ferno approved service on the stretcher Modifying the stretcher can cause injury and damage Use the stretcher only as designed by Ferno 1 2 Important Boxes like this emphasize important information Important The hinges can catch and tear the mesh bed surface When folding the stretcher adjust the bed surface to ensure it will not catch on the hinges 1 3 Bloodborne Disease Notice To reduce the risk of exposure to bloodborne diseases such as HIV 1 and hepatitis when using the stretcher follow the disinfecting and cleaning instructions in this manual 2 OPERATOR SKILLS AND TRAINING 2 1 S
11. h warm water and a mild detergent Use a stiff bristled brush but not a metal bristle brush to remove stains if necessary Rinse the stretcher with warm water Dry the stretcher with a towel or allow it to air dry PLASTIC BUCKLE RESTRAINTS The plastic buckle restraints are permanently attached to the stretcher Clean and disinfect the restraints following the instructions above If additional restraints are used with the stretcher clean and disinfect them according to the restraint manufacturer s instructions Ferno Washington Inc 234 3234 00 March 2003 Model 108 D Stretcher 5 4 Inspecting the Stretcher Have your equipment maintenance personnel follow the instructions in Using the Stretcher pages 7 11 and check the following Q Are all components present Q Are all drive screws and stainless steel rivets securely in place Do all moving parts operate smoothly and properly Q Do the stretcher hinges require lubricant Is the stretcher free of excessive wear Maintenance Parts and Service Q Is restraint webbing in good condition with no cuts or frayed edges Q Are restraint buckles free of visible damage and do they operate properly If inspection shows damage or excessive wear remove the stretcher from service until repair is made see Repair Parts and Service below 5 5 Lubricating the Stretcher As needed apply lubricant to the stretcher hinges and center of spreader bars using a lubri
12. kills Operators using the stretcher need Q a working knowledge of emergency patient handling procedures Q the ability to assist the patient Q a complete understanding of the procedures described in this manual 2 2 Training Trainees need to Q follow a training program designed by their training officer read this manual For additional free users manuals contact Ferno Customer Relations page 14 practice with the stretcher before using it in regular service be tested on their understanding of the stretcher Q record their training information A form is provided on page 15 A WARNING Untrained operators can cause injury or be injured Permit only trained personnel to operate the stretcher Ferno Washington Inc 234 3234 00 March 2003 Model 108 D Stretcher About the Stretcher 3 ABOUT THE STRETCHER 3 1 Stretcher Description The Ferno Model 108 D Stretcher referred to as the stretcher in this manual is an emergency patient handling device designed to transport a patient The stretcher is primarily carried by hand but can also be attached to a Ferno Model 35 L Litter Carrier for wheeled transport or transport in an ambulance The stretcher is for professional use by two trained operators Additional helpers may be necessary when transporting heavy patients Stretcher features include OVERALL FEATURES Folds lengthwise and crosswise for compact
13. mited Warranty Summary Ferno Washington Inc Ferno warrants the products we manufacture to be free from defects in material and workmanship for one year except as follows A External finishes gelcoat decals paint etc are warranted for 90 days B Soft goods webbing vinyl fabric foam etc are warranted for 90 days This limited warranty applies when you use and care for the product properly If the product is not used and cared for properly the warranty is void The warranty period begins the day the product is shipped from Ferno or the day you receive it if you have proof of the delivery date Shipping charges are not covered by the limited warranty We are not liable for shipping damages or damages sustained through using the product Limited Warranty Obligation If a product or part is proven to be defective Ferno will repair or replace it At our option we will refund the product s purchase price The purchaser accepts these terms in lieu of all damages This is a summary of the limited warranty The actual terms and conditions of the limited warranty and the limitations of liability and disclaimers are available upon request by calling 1 800 733 3766 or 1 937 382 1451 8 FERNO CUSTOMER RELATIONS Customer service and product support are important aspects of each Ferno product Serial Number In the U S A and Canada for assistance with the stretcher please contact Ferno Customer Relations Telephone ren
14. storage e Spreader bars and legs POLES Heavy duty aluminum poles 4 Handle grips BED SURFACE Bed surface is constructed with polypropylene mesh material and is Fire retardant and meets California State Fire Marshal standards Chemical resistant UV stabilized to resist deterioration from exposure to sunlight RESTRAINTS Two polypropylene restraints with quick release buckles sewn onto bed surface Ferno Washington Inc 234 3234 00 March 2003 A WARNING Improper use of the stretcher can cause injury Use the stretcher only for the purpose described in this manual 3 2 General Specifications In US 90 x 22 x 6 229 x 55 x 15 cm Storage 45 x 9 x 4 114 x 23 x 11 em Load Limit 350 Ib 159 kg Weight 13 Ib 6 kg General specifications are rounded to the nearest whole number Metric conversions are calculated before rounding the English measurements For more information contact Ferno Customer Relations page 14 or your Ferno distributor Ferno reserves the right to change specifications without notice LOAD LIMIT Inspect the stretcher if the load limit has been exceeded See Inspect ing the Stretcher page 13 About the Stretcher Model 108 D Stretcher 3 3 Stretcher Components Sewn On Restraints 2 Hinge 2 Bed Surface Handle Grips 4 Top View Spreader Bars 2 Legs 4 Bottom View USERS
15. y Follow the attachment instructions in the 35 L users manual Always check to make sure the stretcher is securely attached to the cot Ferno Washington Inc 234 3234 00 March 2003 Model 108 D Stretcher 4 7 Using Additional Help Using the stretcher requires two operators They may need additional help when working with heavy patients Operators should maintain control of the stretcher and direct all helpers The diagram shows suggested placement for operators and helpers A WARNING Helpers can cause injury or be injured Maintain control of the stretcher and direct all helpers LOAD LIMIT Inspect the stretcher if the load limit has been exceeded See Inspect ing the Stretcher page 13 Ferno Washington Inc 234 3234 00 March 2003 Using the Stretcher Using Additional Help Helpers Lifting and Carrying Two Operators Two Operators Two Helpers Two Operators Four Helpers Note When a squad of four or more operators is present the senior medical person stands at the head end on the patient s right side and issues lifting and carrying commands 11 Maintenance Model 108 D Stretcher 5 MAINTENANCE 5 1 Maintenance Schedule The stretcher requires regular maintenance Set up and follow a maintenance schedule A form is provided on page 15 The following table represents minimum maintenance

Download Pdf Manuals

image

Related Search

Related Contents

SAExC 16.1 SARExC 07.1 – SARExC 16.1 Con unità di    2 - Toshiba Air Conditioning  EB 2013/LOT/G.14  Alpine PLV-7 User's Manual  Livret secondaire (histoire) - Siaap, La Cité de l`Eau et de l  ode d`emploi  CG-N21P-R01  Samsung Galaxy Tab S (8.4, LTE) Εγχειρίδιο χρήσης(LL)  Manual de usuario LV-910  

Copyright © All rights reserved.
Failed to retrieve file