Instruction Cum User Manual For HI VAC PLUSS 90 LTR/MIN

image

Contents

1. 22 Kg Vacuum at Altitudes The specified maximum vacuum refers to sea level According to local conditions and barometric press ure slight deviations in vacuum reading may be noted As a reference the table below shows several factors by which the indicated maximum vacuum value must be multiplied according to the altitude of location where the measurement is carried out Location Maximum Vacuum Location Sea level 1000m 2000m 4000m F actor 1 00 0 88 0 78 0 60 Before the unit is put on please see that 1 O rings on the push in connector and safety jar legs are not worn out Both these should be well inserted 2 Jars be checked for any crack tubing and lids be tightly placed on the jars The angular connectors must be inserted as far as the stop While unplugging twist and pull 3 Adjust vacuum before use Fully tightened clockwise knob means full vacuum CLEANING AND DISINFECTING After each use jars lids overflow cut off valve catheters etc should be cleaned thoroughly When cleaning is necessary after infective fluid has been evacuated the jars lids and cut off valve can be sterilized by autoclaving upto 120 C for 20 minutes Alkaline cleaning agents and disinfectants based on phenyel may not be used Adherence to hospital directives on hygiene is of prime importance The instructions provided by the suppliers of cleaning agents as well as by the manufacturers of sterilization and or disinfection units must also
2. be followed where application temperature process duration and airing etc are concerned Wwww anandind ecom Page 2 DOC ID NO 3101 REV 01 DATE 09 10 2010 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For HI VAC PLUSS 90 LTR MIN PUMP The unit is fitted with double Piston pump a Please run the unit and see its satisfactory functioning before the base with motors is fitted and the back plate is screwed up Unlike the rotary design NO LUBRICATION IS REQUIRED IN THIS PUMP GUIDELINES 1 Before the unit is used read the Instruction Manual and keep it handy Check that the tubes lids filter push in nozals are tightly placed vacuum control knob is tight clockwise and no tube is kinked 2 Ascertain the flow required Required vacuum can be obtained by occluding the patient tube and adjusting the vacuum release valve 3 When the level reaches the maximum marked on the jar redirect the flow to the empty jar with the changeover lever and switch over the patient tube also 4 Fluid must never enter the pump and no lubrication is required 5 The unit has to be used by trained medical personnel and maintained by Maintenance Engineer www anandind com Page 3 DOC ID NO 3101 REV 01 DATE 09 10 2010 www suction india com Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For HI VAC PLUSS 90 LTR MIN TROUBLE SHOOTING Possible source of troub
3. of used product packaging in safe manner so as not to harm stray cattle children and environment WARRANTY CARD Model No _ LLL eee Le LL LLL LLL INN eee eee Date of Purchase Dealer Name paal ANAND MEDICAIDS PRIVATE LIMITED Regd Office 33 16 Punjabi Bagh Extn New Delhi 110026 India Tel 91 11 25225225 25229206 42464264 Fax 91 11 25225062 E mail sales anandind com Works 1460 M I E Bahadurgarh Haryana 124507 India EC REP KALEIDOS SH VIA PONTIOA 4 2012 MILANO ITALY Www anandind com Page 5 DOC ID NO 3101 REV 01 DATE 09 10 2010 www suction india com
4. An ISO 9001 2008 13485 2012 Certified Company Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For HI VAC PLUSS 90 LTR MIN CE 2195 t E Bs ie tee E 7 reat npka j ze reg Hai i iair On Off Switch g Bacterial Filter Vacuum Gauge Release Valve Electronic Safety Jar Vacuum Connector Changeover Lever Patient Connector lt ____a Jar Lids lt _ __ Cut off Valve i ds i s ki N PA i 2x2 5 ltr Jar f by f b Foot Switch Dear Customer Congratulations on your purchase of this versatile and need oriented suction unit It will serve you well for years if properly looked after It is designed for use in hospitals and nursing homes 1 Non corrosive and shockproof Suction Unit has piston pumps on 220 230 V Motors 180 watts No lubrication is required and it is not for continuous drainage of body cavities 2 The panel has a vacuum gauge with release valve 2 safety jars and an on off rocker switch Below the panel is a 2 way changeover lever for collection in one jar at a time 3 The unit is fitted with double overflow preventive devices one in each jar lid and the other away from the lid in the form of safety trap jars for each collection jar fitted with electronic sensors which in the event of fluid entering strips electric connection thereby preventing fluid from entering the pump 4 Removable polycarbonate filter on the safet
5. le Check Action to be taken Power Supply Voltage power socket Electrical cord Plug connections damaged cord Motor does Not Run Check if any safety jar is activated Open the safety jar clean amp dry the jar and replace cap for re use Leak within the pump or in the external Isolate the source of trouble by carrying out suction circuit the checks outlined External cause Push in connector O rings Lid gasket Condition Push in angular connectors Tubing Filter paper Condition position of housing Blockage or kink in tubing within the Isolate source of trouble as follows Inadequate Suction Performance pump or in the external suction circuit Remove the safety jar from the pump leave the suction connection open If the vacuum gauge now indicates zero vacuum the cause is external External cause Bacteria filter safety jar overflow valve in the Investigate the whole external suction circuit lid float valve push in connectors tubing etc for blockage s float valve sticking kinked tubing and rectify If the vacuum gauge still indicates a vacuum Pump does not suck however the cause is internal Vacuum gauge indicates a vacuum WwWwW anandind com Page 4 DOC ID NO 3101 5 J REV 01 www suction india com DATE 09 10 2010 Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For HI VAC PLUSS 90 LTR MIN TERMS OF WARRANTY Anand Medicaids Private Limited warranty the high
6. quality and workmanship of each Anand s HI VAC PLUSS 90 LTR for a period of one year subsequent to the date of delivery by the company During this period faulty material will be replaced free of charge This warranty does not extend to components that are subject to wear and tear in the course of normal operation or due to improper treatment maintenance as per instructions Further conditions in accordance with international standard IEC 601 1 item 6 8 2b The manufacturer is only responsible for effects on the safety the reliability and the performance of the appliance if e Installation additions adjustments modifications or repairs are carried out by personnel authorized by the manufacturer e The electrical installations within the room concerned satisfy the requirements laid down by IEC e The appliance is used in full accordance with the instruction manual which is solely a guide and no substitute for professional training The safe and effective use of this product largely depends on the skill of the operator We are not liable for any damages due to mishandling or improper and unauthorised use e The company reserve the right to change technical specifications designations and catalogue numbers without prior notice Note Ensure that your electrical wirings are well earthed with 1 line and 1 neutral phase and your voltage is between 220V 230V 50 Hz Ensure that the suction unit should not be lifted above human body level Dispose
7. y jar entraps the splash droplets and is autoclavable The replaceable filter element filters the evacuated air before it enters the pumps and thereby infects the environment The element can be changed after each use and necessarily after infective suction has been done or when it gets wet 5 Additional 2 volt footswitch enables the user to activate and deactivate the pump from a distance The main switch on the panel must be on the On position 6 Before each use the required vacuum can be obtained by occluding the patient tube 7 As the flow rate is high 34 th filling of the jars is recommended www anandind e com Page 1 DOC ID NO 3101 7 E REV 01 www suction india com DATE 09 10 2010 Anand MEDICAIDS Instruction Cum User Manual PRIVATE LIMITED For HI VAC PLUSS 90 LTR MIN TECHNICAL DATA Anand s High Vacuum High Flow Suction Unit Housing Plastic moulded cabinet Capacity 700 mm Hg 10 mm regulable flutter free vacuum control knob 90 Itrs min Pump type Double piston pump Jar 2 x 2 5 ltr wide mouthed Polycarbonate with changeover lever Provided with handle for hygiene while emptying cleaning safety jar with mechanical electronic overflow motor shut off system and autoclavable bacterial filter Tubing 10 mm ID x 2 mtr PVC Vacuum Gauge Bourden type 6 25 cm dia 0 760 mm Hg calibration Power 220 V 50 Hz Single Phase Noise Level 60 dB A 3 Dimension amp Weight 46 x 32 x 86 cms