Home
        USER MANUAL SW-PRO 800/1100/1600/2200VA - xmart-ups
         Contents
1.     SW PRO 800VA 2 200VA  USER MANUAL    USER MANUAL    SW PRO 800 1100 1600 2200VA  UPS   SAI   SINEWAVE   INTERACTIVE       Technical information on this manual is property of XMART    This manual Information cannot be  copied or distributed totally or partially without written approval of XMART    XMART can introduce modifications in their products or manuals without further notice      XMART is not responsible of mistakes or missing information in this manual    XMART is not responsible for wrong use a third part can do of this information    Trademarks and logos in this manual are property of their owners     E SW PRO 800VA 2 200VA  mar USER MANUAL    Quality Power Products    1  SAFETY INSTRUCTIONS    WARNING  This product has been designed to operate safely and reliably for years  Nevertheless  as it is an electrical  device  it is required to read and understand this manual  Keep manuals as references for future consults     WARNING  This product has been designed to be used indoors  protected of water  direct sun light and extreme  temperatures  This device must not be used outdoors  close to moisture of heat sources     WARNING  Do not set objects on this UPS  Handle with care  Do not block UPS ventilation     WARNING  Make sure to connect this unit to proper power line according to selected model  The UPS Technical  Specs sticker shows power rating information  DO NOT connect this UPS to any of its own power ouilets     WARNING  UPS must be installed following inst
2.  PRODUCT DESCRIPTION       SW PRO 800 1100 1600 2000 series offers 4 different UPS models  all of them interactive type with internal automatic  voltage regulation and sinewave output in battery mode          Input Voltage  Vac     Output Voltage  Vac      AC MODE indicator    Load Level     OVERLOAD indicator  ra   BATT MODE indicator  y o OVERLOAD f  aa Q Battery level   4   LOW BATT indicator     FAULT indicator     LcD     ON OFF switch                                 Outlets   Salidas      AC Input   Entrada CA     Input Breaker      RJ 45      USB     RS232                                                                                           4  INSTALLATION       TO MAKE SURE UPS WILL BE ABLE TO OFFER YOU EXPECTED BACKUP  FIRST TIME PLUG  UPS TO AC SOURCE DURING 4 TO 6 HOURS TO ALLOW RECHARGING INTERNAL BATTERIES     e This product leaves factory with battery fully charged  however during transportation and storage it may loose a  non determined part of its charge  therefore we recommend plugging it to Power Line for 6 hours before using the  UPS    e Install this unit in any protected environment with a dust free air flow  Also corrosive vapours and conductive  contaminants must be avoided  Do not use UPS outdoors or where either temperature or humidity exceeds tech  specs  Install UPS at least 10 inches away from your monitor to avoid magnetic interference    e Connect phone or LAN cable to RJ11 45 Jack Identified as    IN    and your Router or PC RJ45 port to RJ 
3.  again for 2 to 3 seconds    e Cold start function allows you to power up your UPS and your equipments even during power loss  thus your  UPS acts like a small power generator    6  SOFTWARE    Our software offers great features to communicate your PC and UPS  allowing an effective management of UPS  Capabilities    Software Downloading Procedure  Go to www xmart ups com and select download section  Choose the appropriate  version of    VIEWPOWER    according to your Operative System     PASSWORD  To access as administrator the password to be used is  administrator  VERY IMPORTANT  Download installation and operation manual as well  follow all instructions     7  BATTERIES MAINTENANCE    Batteries  despite its technology  are components that lose capacity after some time and usage  XMART cares for  using first quality batteries in all UPS models    Life expectancy may be shortened by some operation conditions  With higher temperatures and frequent use   batteries tend to lose capacity faster  When UPS is stored for long time it is important to recharge its batteries every 3  months  If batteries are not recharged they will finally get damage  This kind of damage is not a failure so it is not  covered by warranty    Batteries must be checked periodically to assure the appropriate back up     www xmart ups com 1303 SWPRO_800 2200 ENG  4    iE SW PRO 800VA 2 200VA  mar USER MANUAL    Quality Power Products       8  TROUBLESHOOTING  Problem   Possible Cause    Sowtions    LCD is 
4.  of this limited warranty  this product is warranted to be free from defects in materials and  workmanship at the time of XMART supplies the product    Standard warranty times could vary depending on country region or can be extended by purchasing warranty options  Please  check warranty plans and extensions with your local distributor or revise in our web www xmart ups com    2   lf during the warranty period  this product fails to operate under normal use and service  due to defects in materials or  workmanship  authorized distributor or service center will  at their option  either repair or replace the product in accordance  with terms and conditions stipulated herein  Transportation expenses are not covered by this limited warranty    3   Warranty is valid only if the original invoice issued by XMART  specifying date of purchase  serial number and name of the  dealer  is presented with the product to be revised  XMART and authorized partners reserve the right to refuse warranty service  if any of this information has been removed  changed or missing in original invoice document    4   If product is repaired or replaced  repaired or replaced product will be warranted for the remaining time of the original  warranty or for 90 days on repaired part from date of repair  whichever is longer    5   XMART or their distribution service partners reserve the right to charge handling fee if returned product is free of failure or it  is out of warranty because any of the reasons desc
5. 11 45  Jack Identified as    OUT     Plug UPS to a power outlet with a proper grounding  Connect your equipments to UPS  power outlets    e NEVER connect equipments with power consumption higher than Power Capacity of this UPS  such as Laser  Printers or copiers     THIS KIND OF UPS IS NOT COMPATIBLE WITH GENERATOR POWER PLANTS  DO NOT  CONNECT TO ELECTRICAL SUORCE SUPPLIED BY GENERATOR POWER PLANTS SINCE UPS  WILL NOT WORK PROPERLY     www xmart ups com 1303 SWPRO_800 2200 ENG  3    E SW PRO 800VA 2 200VA  mar USER MANUAL    Quality Power Products    o  OPERATION    e For you to get higher performance of this UPS  it is important to understand how it works    e This is an interactive UPS and protects your computer related equipments as well as your valuable information   When minor power failures occurs  electrical surges or sags   your UPS quickly regulates voltage by means of  its voltage stabilization without using batteries  When failure slips out of the UPS regulation range  as in a black  out   UPS inverter starts working to generate power from energy stored in the batteries so you can properly close  all applications  save your data and close operating system    e Under normal conditions  your UPS keeps charged and standing by    e This unit is equipped with a LED indicator to let you know about UPS status    e Power pushbutton is located in UPS front panel  To power up your UPS press power pushbutton once during 1  second  To power off your UPS press power pushbutton
6. OFF even UPS is JAC input is not connected well  Check if the input power cord is firmly connected to  plugged in AC source the mains     AC input is connected to the UPS    Plug AC input power cord to AC input correctly     Battery runtime is shorter  Batteries are not fully charged  Charge the batteries at least 6 hours and then check  the capacity again     If the problem persists  please consult your dealer     Batteries need replacement  Contact your dealer to replace the batteries   Warning or faulticonis  Fan is locked or not working  Check fans and notify your dealer     shown and alarm is The UPS is overload  Remove some loads first  Before reconnecting  continuously sounding  devices  please verify the total loads match the UPS  Capability specified in the spec     Low battery icon is shown  Low battery  Charge the UPS at least 6 hours   on the LCD screen     9  QUALITY   PERFORMANCE   SAFETY    SAFETY   LOW VOLTAGE DIRECTIVE  2006 95 EC  Rt    UPS Part 1 1  General  amp  Safety UPS in accessible areas IEC EN 62040 1  ELECTROMAGNETIC COMPATIBILITY   EMC DIRECTIVE   2004 108 EC     Low Freq  Conducted Disturbances  amp  Signals  IEC EN 61000 2 2             IEC EN 61000 4 5  Line to Line  Level 2  Surge immunity  Line to Earth  Level 3          UPS Part 3  Methods of operation  specifications and test requirement IEC EN 62040 3      IT Equipments  SAFETY  Part 1  General Requirements   IEC EN 60950 1      QUALITY MANAGEMENT    ISO 9001   2000      Any modification ma
7. TPUT   otage regulation batt mae   quency Rang  ransfer Time from normal to Batt mode  Wave fom  BATTERIES   T  untime  typical with PC   TFT 17     hous 10 BE    PROTECTIONS    Full internal protections UPS overload  Shortcircuit  Batt overcharging  Surge Suppression 310 J  Internet Data Line RJ11   RJ45    DISPLAY INDICATIONS    Working Mode  Normal or Battery  Battery level  Load level  Input output Voltages   Alarms    Zbeeps  s  beep 2s    UPS Fault Continuos Beep  PHYSICAL INFORMATION    350 146x 160  a   o   m   v25   B Nema 5 16R  WORKING CONDITIONS   0 90     0  40  C  No Condensing     COMMUNICATION    USB  Serial   RS 232 Opcional  Windows   family  Linux  Unix  Mac OSX    Specifications may change without further notice       USA Headquarters  EUROPE Headquarters  Latin America Headquarters   10540 NW 26th St  Ave  Can Bordoll 60  Nave 4  Zona Ind  San Vicente Il  C  F  A11  Doral  FL 33172  USA Sabadell 08202  SPAIN Maracay  Venezuela   Tel   1 305 406 3664 Tel   34 93 745 9694 Tel   58 243 551 7023    www xmart ups com 1303 SWPRO_800 2200 ENG  7    
8. de by user or operator may affect compliance of the safety and performance certifications listed above   UPS manufacturer is not responsible of any modification made on the product or its accessories after it is manufactured   This product is designed to operate in domestic and commercial environment     www xmart ups com 1303 SWPRO_800 2200 ENG  5    E SW PRO 800VA 2 200VA  mar USER MANUAL    Quality Power Products    10  AFTER SALES SUPPORT  amp  WARRANTY    Support  If a failure or problem is detected please check troubleshooting section in user manual  If problem cannot be solved  please contact authorized service center or authorized dealer    Batteries  Rechargeable batteries can be charged and discharged hundreds of times  However they will eventually wear out   This is not a defect or failure so that batteries wear out is not covered by this warranty    Battery lifetime will depend of operative conditions like working temperature  type and frequency of discharging cycles  Higher  the temperature shorter will be the lifetime  Frequent and deep discharging cycles also will short lifetime  For critical  applications batteries should be revised and replaced periodically  Long storage  longer than 6 months  without required  recharging will wear out batteries  This situation is not covered by this limited warranty since this is not considered as a  defect  Check recharging instructions on user manual    Conditions Limited Warranty    PLUS      1   Subject to the conditions
9. ribed in this warranty    6   If product is out of warranty a reparation proposal will be sent to the user for his approval  If proposal is not accepted   service center will keep product available for the user during 60 continuous days  After this period product would be disposed  and user will not be able to rise any claim    7   Rechargeable batteries  like included in this product  will definitively wear out even under normal operation  This is not a  defect or failure so it is not covered by this warranty    8   This warranty does not cover batteries wear out caused by improper or long storage  over 6 months without required  recharging indicated in product manual   Even performing recharging procedure this product cannot be storage longer than 18  months  Problems on batteries caused by this kind of long storage are not covered by this warranty    9   This warranty does not cover product failures caused by installations  modifications or repair performed by non authorized  person  If product is open by not authorized technician warranty will be considered void  This warranty does not cover failure  caused by inadequate installation or maintenance  misuse  accidents  fire or floods    10   This product can include protection devices like input fuse or input breaker  Activation of this kind of devices is not a  failure it is caused by an improper product installation  Input fuse or breaker reset or replacement is not covered by this  warranty    11   This warranty does no
10. ruction from this manual   The manufacturer is not liable for any damage that might rise from misusing this unit or defective installation     WARNING  Only computer related equipment can be connected to this UPS  DO NOT connect medical equipments   life support equipments  microwave ovens  vacuum Cleaners  refrigerators  or any other appliance to this UPS     WARNING  UPS must be checked  repaired and maintained by qualified personnel only     WARNING     ELECTRIC SHOCK RISK   Inside the UPS there are dangerous high voltages even when disconnected of power line  due to internal batteries    WARNING  In case of emergency turn off the UPS pressing Power Button  unplug it and call technical support     Disposal  We strongly recommend disposing this UPS according to regulations in your   country to prevent possible environmental damages  besides some parts might be   recycled    BATTERY WARNING  DO NOT dispose batteries in fire as it might explode  DO NOT try    to open batteries  there are dangerous liquids inside     2  APPLICATIONS       This is an Interactive sine wave type UPS  It is suitable for all kind of PC related applications  even those using active  PFC power supplies    Do not plug this UPS to electrical sources powered by generators  Usually electrical generators provide a poor quality  power that will force this UPS to work erratically     www xmart ups com 1303 SWPRO_800 2200 ENG  2    E SW PRO 800VA 2 200VA  mar USER MANUAL    Quality Power Products          3 
11. t cover damages produced during transportation from user to technical service caused by improper  packing of the product by user    12   Warranty terms and conditions cannot be modified or extended by third parties without written approval of XMART   Limited Warranty    PLUS        XMART does not warrant that the operation of this product will be uninterrupted or error free during its lifetime  If product  fails to work  the maximum liability of XMART under this limited warranty is expressly limited to the lesser of the price you  have paid for the product or the cost of repairing or replacement of any hardware components that malfunction in conditions  of normal use      In no event will XMART be liable for any damages caused by the product or the failure of the product to perform  including  any lost profits or savings or special  incidental  or consequential damages  XMART is not liable for any claim made by a third  party to XMART or to final user      XMART is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this  hardware product      XMART is not responsible for damage that occurs as a result of your failure to follow the instructions intended for this  hardware product     www xmart ups com 1303 SWPRO_800 2200 ENG  6    iE SW PRO 800VA 2 200VA  mar USER MANUAL    Quality Power Products       11  TECHNICAL SPECIFICATIONS    MODEL SW PRO 800 SW PRO 1 100 SW PRO 1 600 SW PRO 2 200    INPUT   query Range  hases  OU
    