1. e Installation continues and finishes quickly Click button Finish 23 Guide User Manual Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for e GUIDE IR CAMERA The hardware you installed will not work until you restart your computer Click Finish to close the wizard Go to Device Manager to check and confirm whether the driver has been successfully installed If there is GUIDE EASIR 4 listed under Universal Serial Bus Controller it indicates the driver has been properly installed and you can transfer data from the camera to PC now The procedures to go to Device Manager is as follows Clicking My Computer Clicking the right mouse and choosing Property gt Choosing menu Hardware in the System Property dialog box gt Choosing option Device Manager under the menu Hardware Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for e GUIDE IR CAMERA The hardware you installed will not work until you restart your computer Click Finish to close the wizard 24 User Manual es amp 282 m EE IDE ATA ATAPI controllers E IEEE 1394 Bus host controllers E Keyboards 513 Mice and other pointing devices E Modems d pase B Network adapters Ej PCMCIA adapters e Mi Processors 8 Sound video and game controllers E System devices Ge U
2. e FPA setting to ensure accurate temperature measurement the FPA detector was calibrated in different temperature points 7degree 17degree 27degree 3 degree When power on the camera in O degree for example after period of working the temperature of the camera the detector will increase gradually And when the internal temperature of the camera beyond 7 degree FPA setting will take place and will last for about 30sec and during the FPA setting the camera will not response for any operations If power on the camera in a temperature about 8 degree only when the temperature of the camera beyond 17degree this phenomenon will happen again Camera will adjust FPA setting itself automatically to ensure its stable performance Guide User Manual Maintenance To ensure that the EASIR 4 Thermal Camera is kept in good working condition and remains fully operational the following guidelines should be adhered to at all times Non optical surfaces The non optical surfaces of the camera can be cleaned when required with a soft cloth dampened with water and a mild detergent Optical surfaces The lens of an IR camera is very expensive Replacement or repair may be thousands of dollars The anti reflective coating on the surface of the lens is the most expensive part of the lens assembly and is also critical to the radiometric capabilities of the system The optical surface should only be cleaned when visibly dirty Care should be taken to
3. 1 and and OK to confirm e Press the softkey labeled Yes Voice Annotation Voice annotation can only be added before saving an image When freeze an image the Image Capture menu appears To add a voice annotation to the image e Press the softkey labeled Voice e Press the softkey labeled Record to start the recording e To Stop recording press the softkey labeled Stop Up to 60 seconds of voice annotation can be recorded for each image Once it reaches 60 seconds recording will stop automatically e Press the softkey labeled Play to replay the voice annotation before saving e Press the softkey labeled Save to save the video annotation How to get accurate temperature There are a lot of factors affecting temperature accuracy Here is a brief introduction to some typical parameters emissivity background temperature distance humidity and etc Y Note To get accurate temperature you shall hold the camera stably and focus the camera well e Emissivity All objects radiate infrared energy The amount of energy radiated is based on two primary factors the surface temperature of the object and the emissivity of object s surface The default emissivity is 0 98 which is applicable to most surfaces For some special materials or surfaces please refer to the emissivity table to find a right emissivity value You can change emissivity between 0 01 and 1 00 in menu Parameter a
4. User Manual automatic mode AutoSpan Ffal e Press button E to enter Manual mode and to adjust Tmin and Tmax manually y e Press button Fal to increase the Tmax value press button to decrease the value press button E to switch between Tmin and Tmax adjustment mode E e Press button to enter Auto mode and Tmin and Tmax will adjust automatically according to the change of scenery PIC Mode and InfraFusion EASIR 4 could be displayed in visual mode thermal mode and the InfraFusion mode 2 e When there is no menu on the screen press button to enter the PIC mode 3 e Press button to enter the visual mode al Press cd to enter the InfraFusion mode e Press button T to return to real time IR mode E73 e Press button and button E to adjust the InfraFusion percentage Reviewing and Deleting Saved Images To view saved images in the SD card e Press button to activate the menu e Press button to activate sub menu File 15 Guide User Manual ES e Press button to enter the Filelist e Press button Ey and button selected image to switch among different images and press button Ea to view the To delete the selected image e Press the softkey labeled Delete e Press the softkey labeled Yes To delete all the images in SD card e Press the softkey labeled File e Select Del All by pressing softkey labeled
5. avoid oil chemical dirt and touching the exposed lens surface as skin acid left behind from fingerprints can be damaging to coatings and lens substrates After using the imager please close the lens cover Do not use dilution to clean the imager and its accessories especially the optics Use clean soft dry tissue to clean the imager body and the supplied lens cleaning tissue for lens Calibration and Repair Philosophy To ensure the accuracy and reliability of the EASIR 4 Thermal Camera it is highly recommended that the instrument be calibrated at 12 monthly intervals Calibration or repair for the instrument can be obtained by either contacting the address telephone number on the cover of this User Manual or by email to the following address overseas quide infrared com Caution The EASIR 4 Thermal Camera does not incorporate any user serviceable parts Never attempt to disassemble or modify the camera Opening the unit invalidates the warranty Technical Support Technical support for your Wuhan Guide Thermal Imaging System can be obtained by either contacting the address telephone number on the cover of this User Manual or by email to the following address overseas uide infrared com Feedback to Us We have tested and verified the information in this manual to the best of our abilities Yet as we are committed to continuous development and progress you might find features of the product have been changed since the
6. data stream Digital Temperature data stream recordings object IR active video Recording of up to temperature realtime analyze in realtime by endless 25 fps of thermal image data via USB data output recording on PC hard disc disc is the time limit 2 0 to PC hard drives Rugged The camera last long time years of field service designed for Approved for 2 mtr drops in nearly any environment hard work 2 0 Megapixel better assists finding the trouble spot amp know chos offers high resolution visual image better about inspection environment and target Universal AA more convenient to buy the alternative batteries available everywhere battery locally Rugged and ergonomical easy to hold and carry easy your inspection work design overlays the thermal image directly on the corresponding visual image helps to identify where the problem exactly is for comparison and problems locating Versatile accessories 1 Tele lens wide angle lens high 1 to view relatively far object to have wider temperature delivers more value added functions range 350 C or scope to measure objects with high temperature to the camera 1200 C 2 to protect optics 3 for outdoor inspections 2 Protecting cover 3 Sun shield cover Guide User Manual realizes video transfer and operation control Realtime image video data transfer User can record or just monitor the IR sreams on to PC and real time control of
7. first 3 times e Please choose qualified rechargeable batteries and battery charger supplied by the camera supplier e Please charge batteries when the ambient temperature is between O C to 40 C e Do not mix new batteries and old batteries together to operate the camera e Do not mix batteries of different types together to operate the camera e AA Alkaline batteries are not chargeable e Please take out all the batteries when the camera will be left unused for long time e Insert batteries according to markers Buttons Introduction LA There are three functional buttons of EASIR 4 From left to right they are a trigger button T Power on off the camera The input voltage is 12V keep button depressed for more than 3 seconds to power on When powering off keep button depressed until the switch off bar runs fully Focus When there is no menu on the screen press button A to enter focus menu the following info will be displayed on the screen According to menu navigation press button al to focus far press button to focus near press button a E to auto focus Press button T to exit the focus menu When doing auto focus please keep the camera steady to ensure image quality Auto manual mode switch gt When there is no menu on the screen keep button depressed to switch between the manual mode and AutoSpan ManualSpan automatic mode 10 Gui
8. time of printing You are appreciated to let us know about any error you find and your suggestions for further editions by either contacting the address telephone number on the cover of this User Manual or by email to the following address 2 Guide User Manual Overseas uide infrared com System Overview EASIR 4 is a new infrared camera of Guide infrared breaks the IR world with its lowest price and high performance Designed for tough work environments and entry level users EASIR 4 is far more robust and shock resistant for any tough working environment and it is easy to operate and allows for the learners to operate without being trained and take the inspection work easily with one hand Featured with latest InfraFusion technology it helps you pinpoint the problem exactly with the most efficiency Power on the EASIR 4 let the 3 6 LCD bring you into the fresh IR world System Configuration Please ensure that the following items have been correctly supplied o IR Camera with visual camera laser locator e 11mm IR lens amp protection cover o 3 6 TFT LCD with high resolution e 2GB SD card amp card reader o 12 AA rechargeable batteries e AC Adapter amp cable USB extension cable USB driver e Guide IrAnalyser Software o User manual e Wrist strap e Safety case o Soft bag e 30mm Tele lens e 7mm wide angle lens e Extended temperature range up to 350 C o 1200 C high temperature filter e S
9. EasIR 4 Thermal Camera User Manual Wuhan Guide Infrared Co Ltd No 26 Shucheng Rd Hongshan District Wuhan 430070 P R China Telephone 86 27 8767 1991 Facsimile 86 27 8767 1927 Email overseas Dguide infrared com Internet www guide infared com Wuhan Guide Infrared Co Ltd 2009 Version No 2010 02 22 The Quality Management System of Wuhan Guide Infrared Co Ltd is approved to 509001 2000 for the design and manufacturing stockholding in house repair and site servicing of non contact temperature measuring instrumentation Wuhan Guide Infrared Co Ltd reserves the right to make changes and improvements on any of the products described in this manual without prior notice EASIR 4 Thermal Camera complies with current European directives relating to electromagnetic compatibility and safety EMC directive 89 336 EEC Low voltage directive 73 23 EEC Copyright Wuhan Guide Infrared Co Ltd 2009 All rights reserved worldwide No parts of the products may be reproduced transmitted transcribed or translated into any language or computer language in any form or by any means electronic magnetic optical manual or otherwise without the prior written permission of Wuhan Guide Infrared Co Ltd This manual must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without prior consent in writing from Wuhan Guide Infrare
10. IR 4 Thermal Camera steady during operation e Do not use the EASIR 4 Thermal Camera in temperature exceeding its working and storage temperature ranges e Do not direct the EASIR 4 Thermal Camera at very high intensity radiation sources such as the sun carbon dioxide lasers or arc welders etc o Do not expose the EASIR 4 Thermal Camera to dust and moisture When operating the unit near water ensure that the unit is adequately guarded against splashes e When the EASIR 4 Thermal Camera is not in use or is to be transported ensure that the unit and its accessories are stored in the protective carry case o Do not jam the holes or loudspeaker on the camera body o Do not re switch on the camera until 15 seconds later after switching it off e Do not throw knock or vibrate intensely the camera and its components in order to keep them from damage o Do not attempt to open the camera body as this action will void the warranty Keep the SD memory card for the exclusive use of the camera e During using if move the IR camera from hot cold place to cold hot place e g from inside outside to outside inside of a air conditioned car in winter should power off the camera firstly and leave it in the operation site for 20 minutes then power on the camera for normal operation and accurate temperature measurement Sharp and instant ambient temperature change may cause fault temperature measurement and even damage camera s IR detector
11. Press button to save the image and return to live thermal image Voice Annotation o e to add voice annotation the following info will be displayed on the screen In the frozen mode press button XX S e Press button AN start recording voice annotation e Press button to stop recording voice annotation the following info will be displayed on the screen xx S a 2 e Press button to play the voice annotation l e Press button E to enter visual mode press again to return real time IR mode e Press button T to return to real time IR mode Main menu operation When there is no menu on the screen press button to bring up Main menu the following info will be displayed 12 on the screen Guide User Manual R i e nthe main menu mode press button 7 to enter sub menu parameter setting e n the sub menu Parameter press button E to confirm the highlighted option and enter the next sub menu press button T to return to real time IR mode TM A to enter the sub menu File In the main menu mode press button to confirm the highlighted option and enter the next sub menu press E In the sub menu File press button amp button T to return to real time IR mode o In the main menu mode press button to enter sub menu Setup In the sub menu Setup press button E to confirm the h
12. SIR 4 with the PC via USB2 0 to activate this command it will bring a dialog box as following Select Device Iype Please select the thermal image device type ME MBR e Open Film Use this command to open the saved Video file in the directory path of PC The software will play this file and further analysis can be done on it 18 Guide User Manual Guide IrAnalyser Ge Open Image mae E EZ Setup Report External Device Manager 1 IMGODO38 JPG 2 GDIR 2006 7 28 94250 irv 3 GDIR 2006 7 28 94013 irv 4 GDIR 2006 7 28 9423 irv Exit Setup Command Use this command to set a directory on the hard disks to store the infrared video capture image and set other relevant information 7 System setup Thermal Image Video Film FA EJ Capture Saved C Program Files Guide IrhnalyseriCapture Capture Image Save as IRI or JPG file only O Save as IRI or JPG file and open it Frame Rate fs Kinescope Rate Frame Update track view ms Default Palette Film set the directory path to save the video recording Capture Saved set the directory path to save the captured image Frame Rate set the frame of thermal image per second The default value is 25 second Kinescope Rate set the frame of thermal video The default value is 1 frame Update track view update the interval between track circles Default Palette set the palette to be used for the inf
13. cold outdoor climates hand shakes makes sharp IR images do not appear on IR images camera Auto focus for both IR and visual image Innovative AGT auto gate technology 3 6 LCD screen Navigation interface fast ZipZip and best focus by pressing one button only quick buttons 2 places on camera for ergonomical fitness not only functions as shutter but also lens cap free from all disturbing heat caused by optics and electronics inside delivers better view and clear menu with large letter clear instructions for operation step by step efficiently save your inspection time manual electric focus also possible ensures the most stable and accurate temperature reading protects the camera s sensitive optics and detectors clear image presentation and menu reading espcially for InfraFusion easy operation for any users especially entry level users Guide User Manual support image information read in Powerful powerful further analysis live trend analyzes the image with the help of various analysis analysis multipage generation by analysis method and generate report software over 9 IR images real time video recording report generation convenient for demonstration and online Analog video realtime PAL NTSC thermal video monitoring PAL NTSC switchable on one camera output output satisfies customers from different countries and areas realtime recording of IR
14. d Co Ltd Table of the Contents Table O tec OnteniSs T Ern 1 INIOJUCUO Nin AAA dd 1 PICO UNOS o COPPER O O a A NES 1 MANE TANGO sa Te 2 Calibration and Repair PhilO0SOPHY occocccocncocccocncocccocncococonoconcoonconncornnorncnrnnnnnonnnnos 2 Technical SUP DOR NN 2 ize dona c TL 2 SIS CNT OVEIVICW m A Sa 3 System COMMUN AN Me niadasose cerda odiada 3 Teh nii PE idad 3 SISI EE IO cundo tit Rn cian 5 Pans Desch ara ise nego imam dA O OSS A AE 8 EASIR 4 Charging Instruction 9 Buttons INUA aside na eu eaa nd blu ciui ade d Ds ue aur 10 FUACION PE KA NDA suis EI T adas 14 Guide User Manual Introduction This publication provides the necessary information required to safely operate the EASIR 4 Thermal Camera It is important to fully check all equipment with which you have been supplied The equipment should be used maintained and serviced by suitably trained personnel capable of carefully following the procedures and guidelines given in this User Manual All User Manuals and leaflets should be read thoroughly before proceeding with operation of the equipment It is also advisable that all User Manuals and Instruction Leaflets supplied are kept readily available for reference when the equipment is in general use Precautions The following precautions must be adhered to at all times and must be considered in addition to any advised precautions issued at the relevant worksite or work area e Keep the EAS
15. de User Manual Enter PIC mode 2 Ba to enter PIC mode the following info will be displayed on When there is no menu on the screen press button the screen Spot analysis In the PIC mode press button Press button Ey or button Press button T to exit the spot analysis and return to the real time IR mode to adjust the value of X or Y s coordinate InfraFusion Ol In the PIC mode press button to enter visual InfraFusion mode In the InfraFusion mode press button al or button to adjust the proportion of fusion In the InfraFusion mode press button T to return to the real time IR mode The proportion will be saved as the default value when start up the fusion mode next time Laser On Off uA 3 When there is no menu on the screen keep button depressed for 2 seconds to turn on off the laser Ensure the Laser is Enabled in the menu Parameter Manual calibration When there is no menu on the screen keep button T and button A depressed at the same time to calibrate with 11 Guide User Manual shutter When there is no menu on the screen keep button T and button depressed at the same time to calibrate without shutter Image frozen and save When there is no menu on the screen press button T to freeze the image the following info will be displayed on the screen e Press button T again to exit frozen mode and return to the real time IR mode TF e
16. erform auto fucus operation on camera Play command Use this command or press gt to play infrared video If it is play mode perform this command to change it to pause mode Pause Command Use this command or press il to pause infrared video If it is pause mode perform this command to change it to play mode Forward command User this command or press FF to make the video go forward by one frame when playing video Backward command Use this command or press 44 to make the video go backward by one frame when playing video Record command Use this command or press e to record the video capture by EASIR 4 and save it in appointed directory The default saving directory is in the sub directory of capture under installation directory Computer system will denominate the video file automatically Perform this command again after stopping record Transferring Data from the Camera to PC e Before transferring data from the EASIR 4 camera to PC ensure that the PC offers USB2 0 interface and the 21 Guide User Manual USB driver for the camera has been successfully installed in the PC e Power on the camera e Press the softkey labeled File to reveal the menu Storage e Press the softkey labeled 7 and to select Storage and OK to confirm e Press the softkey labeled UFlash to select the storage medium as UFLASH Press the softkey labeled SD Card to select the storage medi
17. ighlighted option and enter the next sub menu press button T to return to real time IR mode 13 Guide User Manual Function operation Thermal camera focusing There are two methods to adjust focus motorized and automatic To motorizedly focus e Aim the lens at the target e Press LA to activate the menu e Press the softkey labeled Far and Near until the image on the LCD is as clear as possible To automatically focus e Aim the lens at the target e Press E activate the menu e Make sure the target is in the middle of the LCD and then press the softkey labeled Auto until the image on the LCD is as clear as possible Image capturing and saving e Aim the lens at the target of interest and adjust the focus motorizedly or automatically above to get a clear image on the LCD and then pull the trigger to capture an image The image will be frozen and bring up the image capture menu e Press the softkey labeled Save If the SD card is in the camera the image data will be acquiescently saved in the SD card Selecting the Palette e Press button to display main menu LA e Press button to enter Parameter e Select sub menu Palette IZA e Press button or button 5 Press button 22 to confirm to shift among different palettes Setting Tmin and Tmax When there is no menu on the screen keep button E depressed to switch between the manual mode and 14 Guide
18. nd Emiss e Tamb To display and adjust the real time comparative scene temperature of target The default setting of this parameter is automatic adjusted by the internal temperature sensor If needed this setting can be adjusted manually according to real temperature of some special scenes like sky or snow of measured target 16 Guide User Manual E Press button and E button to bring the submenu of parameter setting then choose Tamb and select Set option to set the value manually by pressing button e button The new measurement will be based on the saved tamb value until re enter Tamb option and exit which will activate the default automatic mode e Distance To set the proper distance from target the distance range is from 0 1 meter to 30 meters e Relative Humidity To set relative humidity percentage value between O and 100 according to the practical environment Video Output Composite video output PAL or NTSC mode option is available in EASIR 4 With this option you can view the live image captured by the camera on a monitor or a recording device Before trying to use this option ensure that the EASIR 4 camera is switched off e Properly connect the camera to the monitor or recording device with the video cable supplied together with the camera e Power on the monitor e Power on the camera to confirm e Press button ff or button E73 to select PAL NTSC and press button to
19. niversal Serial Bus controllers GUIDE EasIR 4 Intel R 82801DB DBM USB Universal Host Controller 24C2 Intel R 8280 1DB DEM USB Universal Host Controller 24C4 Intel R 8280 1DB DBM USB Universal Host Controller 2407 Intel R 8280 1D8 DEM USB2 Enhanced Host Controller 24CD USB Root Hub USB Root Hub USB Root Hub USB Root Hub tam EE Za
20. ode after adjusting the temperature Execute this command to return to auto mode Gauge Setting Command The program establishes a mapping function for temperature and brightness of each image file This command utilizes this mapping function to adjust brightness of the current opening image file Dialog box of Temp Range will appear after choosing this command Moving the scale pointer to select a suitable temperature range Or click button Auto to restore the original brightness Note e Double clicking the opening image file will activate this command as well EASIR 4 control command 20 Guide User Manual The following command is available if the camera connected with PC via USB 2 0 is EASIR 4 Calibration F2 Send calibration command to the camera Near Focus F3 Press F3 continously to adjust near focus stop adjusting by releasing the bottom Far Focus F4 Press F4 continously to adjust far focus stop adjusting by releasing the bottom Video capture command When playing infrared video use this command under Video Menu or Press Ctrl T to capture the current image The capture image can be done as following e Save as IRI file or JPG file to the appointed directory path e Open as new IRI or JPG file e Save as IRI file or JPG file and open it Note For EASIR 4 the file fomat is JPG Auto focusing command When playing infrared video use this command under Video Menu or Press Ctrl F to p
21. rared video After saving the setup the program will automatically go to the directory when opening infrared video and perform the track circle Menu Bar Menu bar consists of seven sub menu options including File Video Measure Tools View Window and Help Keeping left button of the mouse depressed and moving the mouse will allow you to move the menu bar to any desired place 19 Guide User Manual File Menu The File menu offers the following commands Open Image Open an existing image file or infrared video Close Close an opening image file or infrared video Setup Set the directory where to store infrared video and relevant information Exit the Guide IrAnalyser program Video Menu Palette command Select a palette for the current infrared video Nine palettes as follows are available Image Palette x Image Palette x z 3 45 6 T 39 Auto adjustment command Use this command to choose adjust image color automatically or manually e Auto adjustment the system mapped every image to the appointed pseudo color according to its temperature Manual adjustment mapped the temperature range to the appointed palette via appointing the maximum and minimum temperature then the image will be displayed User can observe the image of appointed temperature range via manual adjustment Note Manual adjustment is to adjust temperature range The image will be under manual m
22. stant red for both powering on and off e Donotuse the adapter when there are non rechargeable batteries in the battery compartment How to use the batteries e Insert the batteries the indicator will not flicker at once Keep button depressed for 2 seconds the indicator will alternatively flickers as green and red and stop when entering the self check interface How to charge with batteries e Charge when power off Insert the batteries and connect the camera with the adapter to start charging and the red indicator flicker slowly The indicator will turn to be constant green when the camera is fully charged e During battery charging if red indicator flickers quickly it means something wrong with the battery charging Please check whether batteries are inserted right or whether battery temperature exceeded maximum temperature limitation which is approx 50 C xia N P d Y Note e The batteries cannot be taken out of the camera in the charging process e The temperature will be relatively high when it reaches to fully charging if the red indicator flickers quickly during the power on reset to remove and insert the adapter it indicates the battery temperature is overly high and the 9 Guide User Manual charging process should be stopped This phenomenon is normal you can wait till the battery turns to be lower then continue the charging process e Please ensure batteries are fully charged and discharged at the
23. the folder where you save the driver program Then Click button next to go further 22 Guide User Manual Found New Hardware Wizard Please choose your search and installation options SS Search for the best driver in these locations Use the check boxes below to limit or expand the default search which includes local paths and removable media The best driver found will be installed Search removable media floppy CD ROM v Include this location in the search C EasIR 4 GUIDE IR Camera usb Drive Y O Dont search will choose the driverto install Choose this option to select the device driver from a list Windows does not guarantee that the driver you choose will be the best match for your hardware e Installation starts When getting to the step as shown below choose Continue anyway to proceed further r m k Found New Hardware Wizard Please wait while the wizard installs the software e GUIDE IR CAMERA The software you are installing for this hardware GUIDE IR CAMERA has not passed Windows one TIO MY MM ido with Windows XP Tell me why this testing is im Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing STOP instalation
24. the his PC screen very powerfull for online camera on PC monitoring of example print circurts QC And other LAB jobs special for fever sensing and veterinary Medical edition the accuracy can arrive 0 5 degree diagnose IP54 rating Water and dust tight no fear to dust and water splash locates the center point of the IR Laser locator helps to locate where the problem exactly is image NO Goverment Free for lease loan and rental use and can be No need for US gov Approvals limitations freely caried over borders Guide User Manual Parts Described LCD Display Charging Indicator Function Softkeys Microphone EN Battery Cover l6 Speaker Visual Camera 8 Laser 9 IR Lens al Guide User Manual SD Card Slot EASIR 4 Charging Instruction do ses P s Y Note slow flicker in the text is about 1 time per second quick flicker is about 3 times per second How to use the adapter e The red indicator light will turn on when the adapter is connected with camera Keep press the button for 2 seconds to power on the camera with the green and red light flicker alternatively When entering self check interface the indicator turns to be red and constant on e Keep button depressed for 2 seconds to power off the camera the adapter indicator will be red and constant on wales i T Note e When using the adapter the indicator will be con
25. uA s cancel When viewing the live image on external monitor the camera screen will become black but you can still use the buttons to control the camera After viewing the live image power off the camera monitor or recording device and disconnect the cable Y Note e he It is required to power off the camera before connecting it to a monitor or a recording device 17 Guide User Manual Infrared Video The infrared video with temperature information taken by EASIR 4 will be transferred in PC through USB2 0 for further analysis by Guide IR software The Infrared video function is displayed in the computer and controlled by the Guide IR Analyser Before the communication please install the USB driver and IR Analyser into your computer PC System Requirements Operating system Window 2000 or higher IE5 0 or higher Software Microsoft Office 2000 or higher Hardware Processor Pentium 4 2 4G or Above RAM At least 512M Independent Graphic Card Using commands for infrared video analysis After connecting the camera of EASIR 4 to the PC and operate the IR Analyser you can use the relative commands to do all kinds of analysis and remote control the EASIR 4 Video Command Use this command to get infrared video from EASIR 4 directly or directory path of the PC where the films are saved o Device Video Make sure the camera of EASIR 4 is under normal working status and connect the EA
26. um as SD Card e Ifthe storage medium is set as UFLASH no hint will display on either the PC or the EASIR 4 screen Image export image analysis live video recording etc can be done in the PC Images saved in UFLASH can be transferred to PC via IrAnalyser e If SDcardis inserted in EASIR 4 the PC will identify the EASIR 4 as a removable hard disk you can copy the saved data to PC or delete them from the card or even format the SD card and etc But you cannot operate on it in the Guide IrAnalyser software e f without SD card in EASIR 4 you have to install the camera USB Driver to PC and use the Guide IrAnalyser software to transfer images to PC Install USB driver to PC When there is no menu in the live thermal image properly connect the USB interfaces of the camera to a USB2 0 port of your PC with the USB extension cable Microsoft Windows launches a Found New Device Wizard to guide you to install the driver as follows Ei Found New Hardware Wizard Welcome to the Found New Hardware Wizard This wizard helps you install software for USE Device If your hardware came with an installation CD wA or floppy disk insert it now What do you want the wizard to do Install the software automatically Recommended 8 Install from a list or specific location Advanced Click Next to continue Cancel e Choose Install from a list or specific location advanced and include
27. un Shield e Tripod mount Technical Specification Guide User Manual THERMAL Thermal Sensitivity lt 100mk at 30 C Field of View Focus 20 6 X 15 57 11mm Focus Automatic or motorized VISUAL Built in Digital Video CMOS Sensor 1600x1200 pixels 2 true colors Image Presentation External Display 3 6 TFT LCD with high resolution Video Output PAL NTSC InfraFusion Visual and IR blending Man Machine Communication Buttons Respond as per operators operation Menu Microsoft Windows style Temperature Range 20 C to 250 C 350 C 1200 C optional Accuracy 2 C or 2 of reading Emissivity Correction Variable from 0 01 to 1 00 in 0 01 increment Measurement Features Automatic correction based on distance relative humidity atmospheric transmission and external optics Optics Transmission Correction Auto based on signals from sensors External Power Operation AC adapter 110 220 VAC 50 60Hz Guide User Manual Environmental Specification 10 C to 50 C Operating and storing 10 to 95 non condensing Operating Temperature Storage Temperature Humidity Encapsulation Shock Vibration Image thermal amp visual measurement and voice transfer to PC Live video transfer to PC Physical Characteristics 111mmx124mmx240mm Yellow amp Grey interlaced or Red amp Black interlaced alternative System Features Speedy 50 Hz or 60 Hz IR especially in
Download Pdf Manuals
Related Search
Related Contents
Z-URCTM 550US - Amazon Web Services Silverstone SST-DS380B storage enclosure AEG Thyro-S H1 Network Card User Manual FR-Notice IE1GDU 取扱説明書を ダウンロード Sony BC-TRW Operating Instructions Philips 29PT8865 29" real flat HD Ready stereo TV OM520 code reader user`s manual Laird Audio Development Kit (ADK) Benutzerhandbuch v2.02 Copyright © All rights reserved.