OptiPix XYZ Software User`s Manual, v1.6.x

image

Contents

1. Company Organisation name Optilia Instruments AB Full verison License number 1234 5678 Light version 30 days demo Name Optilia Email address optilia optilia eu Address Djupdalsvagen 22 Zipcode 192 51 City Sollentuna mandatory lt Back Cancel lt Back Cancel 1 3 Language It is possible to set language for OptiPix upon first start up Alternatively the language settings can be changed from the File Preferences menu Select Language Requires Restart to Apply Changes English Espanol Francais Deutsch Svenska 1 4 Device Resolution and Properties A device has to be chosen upon the first start of the program This device is stored in the register and will be automatically loaded at next start of OptiPix It is possible to change input device later from Device Input Device To change device resolution click on this icon L or select Device Device Resolution To change device properties click on this icon ae or select Device Device Properties Note To quickly change Input Device right click on the camera status label and choose desired device 1 5 Preferences 1 5 1 OptiPix Preferences In preferences user can change the line thickness the measurement units to metric to imperial and define custom categories for counting Preferences can be opened window from File Preferences Preferences Preference
2. Optilia Alexander a B information 2 I4 12 07 2042 13 13 mL Z Measurement z StartFrame StopFrame Z mm from start D Measurement t M E Refractive Index Z Measurement results d 1 00 Connect to device Thumbnails en ZMeasurement 12 0 Measurement 12 0 Measurement 12 0 PU eeecsWises 7 2012 T141643322 F 20127141627251 7 20127141706249 ipg JjPg Jpg txt Notes NotePad 2 2 1 File Menu e New Measure Create a new measure for current case e Export Case Export case data from database to windows file system e Create Report Create a PDF report of the inspection 2 2 2 Case information In case information view the name id number company and operator of the current case are displayed Inspection date and previous examinations are also displayed For more information about management of the examinations please refer to Working with a Case Case Inftormaton TestCase 12345 55623 Company Inc Jahn Dae 45 09 2011 10 54 2 2 0 Z measurements The Z measurement interface helps user to perform measurements using the measurement instrument This interface contains the start and stop frame The start and stop frames displays the first respective the second captured image together with the measured value The interface also contains the current distance from the start frame as well as a trigger button For further instructions on the XYZ measurements please refer to XY
3. 1 00 4 New measure When the stop point is set both the start and stop image can be viewed in the start and stop frame The distance between the start and stop surface is displayed in the digit field An image of both the start and stop frame has been saved in the current examination folder The measurement result is burnt in to the image an example of such an image can be view below To make a new measurement click New measure 23 Note 1 Use the green help area to keep the start and stop point centered in the image Note 2 Optical Path of the image rays in other material than air vacuum is L n L air x n where L is the thickness of the material and n is the refractive index of the material This means that the actual thickness of a protective coating on a PCBs is n times the height of the measured thickness which is calculated by OptiPix 6 3 XY Measurement The XY measurements enables distance measurements directly on the screen Opti Pix provides a lot of different types of measurements and it is recommended to use the distance measurement to measure x and y measurements Please refer to Measurement Analysis of OptiPix for measurement and analysis tools for further functionality 24 7 Working with Local Files In the folder structure the user can choose the folder destination in which to save or recall images Choose a destination folder by selecting File Set Destination Folder Th
4. Full HD PC 24 1920 x 1200 Graphic card Direct X compatible graphics card is recommended to avoid unnecessary load on the CPU Avoid using integrated simple graphics cards Recommended ATI Radeon HD 5000 6000 Series nVIDIA GTX 500 Series Three USB2 0 ports PCI express x1 All rights reserved The information contained herein is designed only for use with Optilia Instrument s systems Optilia Instruments is not responsible for any use of this information for other purposes Optilia Instruments shall not be liable to the purchaser of this product or third parties for damages losses costs or expenses incurred by the purchaser or third parties as result of accident misuses or abuse of this product or unauthorized modifications repairs or alternations to this product or failure to strictly comply with Optilia Instrument s operating and maintenance instructions Optilia Instruments shall not be liable for any damages or problems arising from the use of any options or any consumable products other than those designated as original Optilia products or Optilia approved products by Optilia Instruments Optilia Instrument shall not be held liable for any damages resulting from electromagnetic interference that occurs from the use of any interface cables or devises other than those provided by or designated as Optilia approved Products by Optilia Instruments OptiPix O and OptiPix XYZ Software are developed by Optilia Instruments AB Dju
5. Click on an image to insert into report Click on an image to insert into report Click on an image to insert into report Click on an image to insert into report Click on an image to insert into report Click on an image to insert into report Alexander Printed name of Operator Signature of Operator File E Inspection Date Inspection RK Optilia 12 07 2012 13 13 Additional Field 2 Additional field from Additional field from preferences 2 up to 7 preferences 1 up to 7 Notes Notes is included into report ZMeasurement 12 07 2012 a ECT ur e AN P i os Wol m TU g a FG a 2 LF bj H rt Click on an image to insert into report Click on an image to insert into report Click on an image to insert into report Click on an image to insert into report Click on an image to insert into report Alexander Printed name of Operator Signature of Operator Saving Examination in PDF for Printing Emailing Click File Save PDF to save a PDF file of the report for printing and or e mailing A PDF report will be generated and displayed The detailed information of each image such as measurement and comments will be added automatically to the report A PDF reader must be installed on the PC 19 6 XYZ measurements The Z measurements uses external measuring instruments to measure objects with the video from the microscope To use these measurements you need to connect the measurement instruments The XYZ measurement is autom
6. Pro HG USB Device 3 vx Generic SD MMC USB Device p Generic SD MMC MS MSPRO USB Device p Generic SM xD Picture USB Device i tx SAMSUNG HD322GJ SATA Disk Device JA Display adapters i DVD CD ROM drives s Human Interface Devices cu IDE ATA ATAPI controllers gt m Keyboards A Mice and other pointing devices Monitors Dor ORAS D Processors 4 Sound video and game controllers JE System devices Q Universal Serial Bus controllers 3 Right click on the DMX1 USB device and select Update Driver Software 4 Select Browse my computer for driver software 5 Browse for the location of the CD partition and click Next 6 Choose Install this driver software anyway when windows informs that it can t verify the publisher The second driver should be installed the same way 21 When starting the XYZ Measurement Database of OptiPix the software will automatically find the measurement devices that are connected to the computer If there are no devices connected or if they are incorrectly connected a pop up will inform the problem Connect your measurement devices and press Connect to device the software will then again try to find the measurement devices XY Measurement StartFrame Stop Frame X mm from start T LI Y mm from start 1 Connect to device 6 2 Z measurement The Z measurement is used together with the focus of the microscope to measure a thickness or height on an object in the video The followi
7. Z measurements Z Measurement StartFrame StopFrame Z mm from start A HH f Set STOP Point 2 2 4 Toolbar The toolbar includes the functionality to record audio Record Audio D 2 2 5 Inspection folder Double click on a picture or document to open it KM68 ZMeasurement 15 0 ZMeasurement 15 0 ZMeasurement 15 0 9 2011 T 132130208 9 2011 7104930540 9 2011 T132130208 jP3 jpg JPG jJpa Jpg txt l Right clicking a picture will open a pop up menu where the user can open the image open the text file associated text file for writing comments about the image save a copy or delete the image Bs A O mm ent 12 0 ZMeasurement 12 0 ZMeasurement 12 0 223i 41643322 7 2012 7141706248 7 2012 1141627251 jpg txt zZMeasurement 12 0 z7Measurement 12 0 7 2012 T141643322 7 2012 T141706243 2 2 6 Note Pad Write notes about the current examination in the notepad Written text will be saved and loaded automatically for each examination Notes 10 3 Starting and Initializing the XYZ Measurement Database Make sure to have the USB Dongle for Opti Pix XYZ is plugged in to an available USB Port 2 Start the software Case manager will be opened automatically 3 Load one of the existing cases or click New Case to add a new case To get more 11 help with case manager please refer to Section 4 Case Management The Case Manager can be closed and the user
8. can work with the local Windows file system without having a connection to database Refer to Section 7 Working with Local Files to get more help on working with file system Case Manager Case ID Search Case Name Case ID Case Company Case Operal New Case Delete Case Close 4 Case Management Case Manager allows the user to add new cases or search and open an existing case in the database Search Category Search Field Case ID Case Name Case Company Case Ope Open Case 1 Project 12 124 Optilia John Smith Case New Case greet 3 Optilia John Smith Delete Case Close Case Manager is opened automatically when the software starts It can also be opened from the menu Database Open Case Manager or by clicking this icon 4 1 Adding a new case To add a new case click Database New Case or on this icon er and fill in the relevant information A new examination folder with the current date will be created and a case will be opened automatically 12 Add Case 4 2 Opening a Case Open Case Manager Double click an existing case or click Open Case 4 3 Finding a Case search the database by Case Name Case ID Case Company Case Operator The search result will be displayed as the name is being typed 13 Case Mananer Case Name 23 Case Company i Case ID Case Company Case Ope Case Operator 1 Project 38 238 Optilia John
9. choose another category in the category window When finished counting objects press done To modify the name of the categories go to File Preferences Note Make sure not to close the category window while counting e Select N To use the selection tool click on the icon or select Measurements Select Select an object measurement on the image to change move or delete it Note When selected right click on the object to change or delete it e Export Measurement Results Measurement results are recorded in a text file with same name as the image file in current destination folder The results can also be exported to a new text file and or renamed 10 2 Annotation 30 e Text A To write text in an image click on the icon or select Measurements Text Click on the image to put the text A new window appears where user input the text e Annotation with Line To write an annotation with a line click on the icon or select Measurements Annotation Line Draw the line and a text window will appear Write a text or leave it blank Note Leave the text blank to just draw a line 10 3 Tools 31 e Compare Images S To compare images click on the icon or select View Compare Images A new window will appear Select View and choose between 1 2 or 4 images To start comparing images drag one thumbnail and drop it onto one a frames in the compare window or double click the thumbnail see image below T
10. image where the user can write comments about the image These comments will also be part of the report if the image is included ZMrosuremeni 124 zZMeasurement 12 0 J 2012 Ti41706249 7 2012 T141627251 Jpg txt zZMeasurement i2 0 Measurement 12 0 7 201277 141643322 2012 7141706249 txt txt 2012 07 05 T172700220 txt Notepad File Edit Format View Help Image Name Untitled Device Optilia 2 0MP Camera Resolution 1600x1200 Magnification Predefined 50x Calibration 0 004775 Ommernts Comments for a specific image 15 5 5 Recording Audio To record an audio memo connect your microphone before starting OptiPix and click this icon U in the Database toolbar Audio level bar will be displayed Click stop icon to stop recording An audio file will be created in the folder Audio recording will stop automatically in 3 minutes EN B To listen to an audio memo click on the audio file and default media player will start playing the recorded audio oe Audio File A20082012 110905 Wav Note OptiPix uses default audio recording device of the computer If the audio level bar doesn t respond to your voice check the default audio recording device from Window Control panel and set to microphone input if it is not already selected 16 5 6 Reporting and Exporting Cases Exporting Case To export the documents from the database click File Export Case on the database
11. menu For each examination all images and reports will be exported to a user selected folder Exporting Image To only export a single image click File Save a Copy or this icon a Creating Report The user can create an inspection report interactively by clicking File Create Report on the database menu There are 4 main Sections in the report e Menu save and load report templates as well as saving a PDF report for printing and or e mailing e Title User can add logo and title to a report by clicking on the respective area To save the logo and title as a template click File Save Template To open a saved template select the desired template by clicking File Open Template By clicking File New Template the user creates an empty template e Inspection Details All the case information and the notes from the inspection will be automatically shown in this area e Image Area User can add up to eight images by clicking on them in the inspection folder To remove any image from the report click on the image in the report 17 Menu Title Inspection details Image area 18 Create Report p Click hereto add Logo Click here to add title and address Inspection Date 12 07 2012 13 13 Additional Field 2 Additional field from Additional field from preferences 2 up to 7 preferences 1 up to 7 Click on an image to insert into report Click on an image to insert into report
12. or by dragging the radius In order to use the first method press the icon or select Measurements Radius Radius 3 Points In order to use the second method select Measurements Radius Radius By Radius Angle amp To measure an angle there are two different methods either by selecting three points or by drawing two lines In order to use the first method press the icon or select Measurements Angle Angle 3 Points In order to use the second method select Measurements Angle Angle 2 Lines e Curve 2 To measure a length of a curve press the icon or select Measurements Curve Click and draw the curve in the picture e Area Q To measure an area click on the icon or select Measurements Area Click and draw the perimeter of the area The area will close when releasing the mouse button e Polygon E To measure using a polygon click on the icon or select Measurements Polygon Click the polygon s corners and double click to close it 1 2 3 e Count Y To count objects click on the icon or select Measurements Count A new window will appear where users can choose a category When user has chosen desired category start counting objects in the image by clicking on them When you name a category the counting object will be marked with the first letter of that name in a certain colour In the measurement results window however the full name will be displayed To count using another category simply
13. ruler depends on the current calibration To rotate the ruler select the object and right click on it e Grid H To project the grid on the screen click on the icon or select Measurements Show Grid A new window will appear to input the size of each grid cell in mm or inches Crosshair T To project the crosshair on the screen click on the icon or select Measurements Show Crosshair e Rectangle To project the rectangle on the screen click on the icon or select Measurements Rectangle A new window will appear to input the length of the sides of the rectangle in mm or inches Graticule L To project a reference semi transparent image on screen click on the icon and select the reference image with exactly the same resolution as the live image Opti Pix will automatically switch to full screen and project the graticule over the live image Press ESC to exit full screen e Change Font amp Color A To change the font click on the icon A new window appears where user can choose font type colors for the text This will be stored in the register i e Change Color of objects EE To change the color of the objects click on the icon A new window appears where user can choose colors of the objects This does not affect the color of the grid nor the crosshair Zoom and Panning There are four ways to zoom digitally both in live and still image mode zoom in zoom out zoom to fit and full size Turning
14. OptiPix XYZ Measurement User s Manual OptiPix E 09 E ee ee eee lola x File Device Magnifications View Measurement Database Help 4 CL O0 Db O0 v Ahea Q Q Rd rd o ae XYZ Measurement Database 8 X r4 File Examination Measurements t Case Information m TESTPCB 123 32 21 8 Optilia JohnDoe 9 m i c z 8 28 10 2011 09 18 xo Z Measurement OOM StartFrame Stop Frame Z mm from start ERN Refractive Index C mh lt Set STOP Point a ZMeasurement 02 1 ZMeasurement 02 1 XYMeasurement 01 1 20117115926559 1 20117115757740 11 2011 712264083 Jpg 4jpg Sha aKa e XYMeasurement 01 XYMeasurement 01 XYMeasurement 01 11 2011 712403713 11 201112481913 11 2011712493452 6 jpg 9 jpg 0 jpg JENNEN AH aes iz Notes sjnsequeuisJnseej Select an item by left mouse button Digital Zoom 62 Magnification Predefined 200x Calibration ratio 1 071 um pixels 1600x1200 RAE 100 This manual describes how to use OptiPix XYZ Measurement software Table of Contents T Jdnsrallauon end startup First RUN sssavmsndsicaniasnstihavanatisavanatesavassinernanteneverataavaretaawatinarn 3 i NEN So TOMI STC Ue aati UU 3 12 USING OOM PICTON TAS TIESETITIQ acter cee e e un e pea en pu hh obe an EE E 3 Co BENGU hy arte gate tele atte teeta PEE 4 1 4 Device Resolution and Properties cccccccccsccceseceececseeceecceceseeeseece
15. Smith Delete Case 5 Working with a Case Inspection folder contains all data of each inspection Open the Case Manager to create a new or load an existing case 5 1 Managing Inspections When a new case is created a new inspection folder is also labeled with current date and time If an existing case is opened the most recent inspection will be loaded All other old inspections can be loaded by selecting them from the drop down inspection list Case Information Project 12 124 Mntilin Lahn Ornith 17 08 2012 15 23 17 08 2012 13 51 To add a new inspection to the case click File New Inspection from the database menu 5 2 Capturing an Image Capture an image by pressing F11 of your computer keyboard pressing the foot pedal or the image capture button of the Flexia Definition For live and still image functions please refer to Section 8 Open and Save Images When a user double clicks a recorded image in the finger folder the image will be displayed for measurement or analysis For measurement tools please refer to Section 6 XYZ Measurements and Section 10 Measurement Analysis 5 3 Writing Notes Comments and text for the current inspection can be written in the Notepad 14 5 4 Writing notes for the image Comments and text can be written for a specific image by right clicking on the image and choose Open text file A new window will be opened showing information about the
16. atically started when opening the XYZ Measurement Database 6 1 Installing the measurement instruments To install the measurement instruments you first need to connect them properly to the computer First of all the measurement instruments is connected to the DMX data transmission box This box is then connected to the computer via USB The pictures below show how to connect the measurement instrument to the computer USB to Computer gt gt There are two drivers that have to be installed to use the DMX box These drivers enable OptiPix to communicate with the DMX USB via a virtual communications port VCP The first driver is a USB serial converter which establishes the connection to the DMX USB through the USB interface and makes the data transfer availably to a virtual communications port VCP The second driver is this virtual communications port VCP which allows OptiPix to contact the DMX USB 20 To install the drivers first connect the measurement instrument according to above description and insert the provided CD then follow the steps 1 Go to the Control Panel in Windows Open the Device Manager via System and Hardware 2 Find the DMX1 USB device in Device Manager It should have an exclamation mark on it See image below xz Device Manager m File Action View Help eig H nz iS 4 ay OPTILIA RDSW 1 gt 4M Computer 4 Disk drives gp Generic Compact Flash USB Device p Generic MS MS
17. e images in this folder are displayed as thumbnails beneath the folder structure To hide the folder structure click this icon To create a new folder click this icon a or right click inside the box to choose new folder The created folder will now be the destination folder Note By right clicking in the file structure or on the thumbnails user can choose from a number of different tools like copy paste and rename 20 8 Open and Save images E e To open an image but keeping the destination folder click this icon L or select File Open Image then choose which image to be opened To load a thumbnail image or a document from the destination folder double click on it or right click and choose open If the image contains measurement objects the measurement results will also be loaded Note that these measurements are part of the image and cannot be changed as they are burnt into the image 4 o 7 Ve P1029132645 jpg P1029132546 jpg 2010 08 16 T13336 448 j x A e test xlsx test Ext test docx To save an image there are two options e Save the image with a user specified name The measurement results will be saved with the same name The image is stored as a jpg file and the results as ixt file This is done by clicking on this icon me or selecting File Save Image Hot key Ctrl S e Take a snapshot of the image The file will be automatically labeled with date and serial numbe
18. eeesseeseeeseeeess 4 to PYCICVENCCS vats since bacntaicentctaedeut stacker atutndas atecutosstecutarateteduncduanes ctuactuactuteiwsetweneweatocntaes 5 1 5 1 OPUPIX PIETEIENCES cu asus iets eonton ewww ee n uten quus 5 1 2 AZ PF VCICIONCCS oi osaisns 5 2 XYZ Measurement Database OVErVview cccccccccseecceseeceececeueeceusecsueessueesusessueessaees 6 2 1 Project Database and its S CUIILY ecccccecccceececeeeeeceeeeeseeesseeeesseeeesseeeesaaeeeseaes 6 2 2 XYZ Measurement Database Components ccccecccseeeceeeeeeeeeeseeeeseeeeseeeeseeesees 7 3 Starting and Initializing the XYZ Measurement Database eeeeseuss 11 4 ASS Managemen seseque ianen Geta t etie ciere uod aeons R 12 AM JAOdifig anew CAS vss ques ida toque tc ce us de xh Ode qu iege qu cU quu eu ede oS put e OS d uus 12 42 Opening GaSe secant imm tin e ORE nm ieri tendanbetdan den da teni dam esi dan damn 13 ASS FNAN A OaseisssastiuttuM aatis tveft an asedt E uadit dandi E 13 ox Mong wid Se ets dct esc ote oon doct nec outer catus htec ee ee ee 14 Sk IWIAMAGINGAINSD SCIONS massae peus uni aVhr tunt eo busca eter us Ra un ht e teas ho but ipu 14 Sez Capung a AOC tis ast es DOES RE 14 9S9 WNUN INGLES usus or ene eae aia aaa uod aou tae ea ana 14 5 4 Writing notes for the image sonoro tad tediteud iere teo viuDvtesviesoboredudvteredebevcetubelzbpies tos 15 De ico cellae FICO RR 16 5 6 Heporli
19. ng steps are done to make a Z measurement otart by setting focus on the surface you want to start measuring from Use the video view in OptiPix analysis window to set the focus When the surface is in focus you press Set START Point Z Measurement StartFrame StopFrame Z mm from start LI Refractive Index 1 00 2 We Set START Point When a start point has been set the start image can be viewed in the start frame and the Z distance from the start will displayed in the digit field The Refractive Index parameter is used when not measuring in air For example when measuring the thickness of a protection coating you enter the refractive index of the coating in the Refractive Index box The distance showed in the digit field is always the length read from the measurement instruments multiplied with the refractive index 22 Z Measurement D StartFrame StopFrame Z mm from start ET rca mw TO IE Refractive Index r yI 1 00 S Set STOP Point 8 MET TRIS P LI A i s em bs r s y Continue by moving the microscope to set the focus on the surface you want to measure to While moving the microscope the current distance from the start point will be display in the digit field When the stop surface is in focus click Set STOP Point to finish the measurement Z Measurement StartFrame StopFrame Z mm from start BST Refractive Index
20. o clear the compare view right click on the image to clear or click to File Clear Window to clear all images The user can Zoom In Out and rotate each individual image Slide the rotation bar or click the rotation buttons to rotate the image up to 180 degrees Compare Window So File View 0 lilium washington ily 1 1920x2560 jpg Compare Live Image To compare the live image with a reference image click on the icon or select View Compare Live Image A new window will appear To start comparing images drag a thumbnail and drop it onto the reference image frame in the compare window or double click to the thumbnail The reference image can be saved and reloaded by clicking File Save Compare Live Window and File Load Compare Live Window e Image Adjustment L S To adjust colour contrast and other graphics properties of the image click on the icon or select View Image Adjustment A new window will appear If Opti Pix is in live or still image mode different windows will be shown In live image mode user can only flip the image and change the contrast Adjust Image Video tL In still image mode user can also change the red green and blue colour mix as well as brightness and contrast E ee Note Select both flip horizontal and flip vertical to rotate the image 180 32 33 SN e Rulers To show the ruler click the icon or select Measurements Show Ruler The size of the
21. ontinue b Choose a folder in where to install Opti Pix Click Next and Next again to start the installation c When the installation is complete click Close to exit the window 1 2 Using OptiPix for the first time 1 e MEC Insert the software protection dongle into a free USB port on computer If a full version of the software has been ordered the protection dongle will be found inside the product box From Windows main menu click Start All Programs Optilia OptiPix and run OptiPix select language from the list From the Introduction dialog box select a Full Version if a full license has been ordered and the software protection USB dongle All software functions will be enabled b Lite Version if a lite version has been ordered image view capture annotation and only distance measurement on image will be enabled c 30 days trial version for trying the software for 30 days All software functions will be enabled for 30 days Skip part 7 Fill in license number found in the package and the other requested information PLEASE READ THE LICENSE AGREEMENT CAREFULLY before using OptiPix select device from the Input Device list The software will start showing live image from the camera Register Your Copy of OpiiPix Introduction Please Fill in your license number and the additional information This setup will help you register your copy of Ooi or start the demo version Choose your version
22. pdalsv gen 22 95 192 51 Sollentuna Sweden Phone 46 0 8 35 33 60 Fax 46 0 8 35 33 63 e mail Info optilia eu web www optilia eu N ili ptilia Revision B August 2012 Copyright 2012 Optilia Instruments AB 36
23. r This is done by clicking this icon de Hot key F1 1 To export the measurement results only right click on the measurements results table and choose Export Measurement Results or select Measurements Export Measurement Results This file will be saved in the destination folder 26 9 Magnifications and Calibrations 9 1 Magnification To create a new magnification select Magnifications Edit User Magnifications and then click on the Add button to add a new magnification See picture below Select the new magnification and click on the OK button To start calibrating click on the calibrate icon See next section for further instructions For quick selection of magnification right click on the Magnification bottom of the OptiPix PCB 10mm 2 jpg window and choose desired magnification Flexia Definition 500x Flexia Definition 250x Flexia Definition 170x Flexia Definition 100x Flexia Definition HM 500x Flexia Definition HM 250x Flexia Definition HM 170x Flexia Definition HM 100x Magnification Flexia Definition Hrvrrovx reemorevorrr tio 1 162 um pixels PCB 5mm 8 a RE 2 9 2 Calibration To calibrate a selected magnification place a Micrometer Scale or a Ruler depending on the magnification of current optics in the live image and focus To calibrate select Magnification Calibrate Magnification The image of the Micrometer Scale or
24. rig and EXPONO CASCS eot ordre ma md eim 17 6 AY Z measureimehliS susx vido sevi crea Scene Surio unco ea ep eee ae 20 6 1 Installing the measurement instruments cccceeeceeeceeeeeeeeseeeseeeseeeeneeeseeeeeeeens 20 02 zZInedslHlelTielllss5ododidudadutodudodunoDqdoducuyodudqe09qdudq Dndodun dedudcuudedud cus detoduns Pa tatan ab adas 22 S EP S eiie ER S nm 24 Zs WOKNG WII EOCSLEIIGSiscetiuk indi E REIR nU EUIS Du uta ERAN CR LOIS NE N Gr LE VOR CD RT OE 25 8 Open AN Save images onian aaa aan aaa adaa a aaa aa a aiaa 26 9 Magnitications and GallbEAllO IS sencie ci od tare qe a a a E E 27 IE MIOCA EE E Um 27 9 2 OCA AO k Ojl l a vetat aste E E qtue 28 10 Measurement and ANALYSIS sussussnwiwntenioutiuinni wut Dqu sodio D de uc d do Dr enit dien cites va acsce dvd eed 29 10 1 MIGaSUT GITIGDIES css ott eme Sho O mu e emet ume EIER RE E URS 29 10 2 JANMOUAUON ses ett cst eec Unde Utd bur biu bed iur bede esr bere bos E dubie prdubid Med noel ti eh eis 30 Eo Eoo re 31 Vie oC HEP 35 12 System Requirements iiec eene unte tante nao reto SERE Ue SEPo n EE EHEd eH per tat untra Me pe ANN OK Ren UNE 36 1 Installation and Startup First Run 1 1 How to Install Opti Pix Prior to installing OptiPix user needs to install camera Device Drivers To install Opti Pix user has to run the provided installer file Double click on it and a new window will be displayed a Click Next to c
25. s OpiPix Preferences XYZ Preferences 1 5 2 XYZ Preferences In database preferences user can change the database location and also add the additional information for new cases Preferences XYZ Database Preferences Preferences OpiPix Preferences Database Path ptiPixDatabase Choose Path XYZ Preferences CENE Additional Information for a New Case Item Add Add Add Add Add Add Add 2 XYZ Measurement Database Overview The XYZ Measurement Database is a database module to OptiPix It allows users to create manage and archive pictures and data from XYZ measurements The XYZ measurements helps the user to measure heights and thicknesses as well as measure distances within a larger area than the picture The XYZ Measurement Database together with OptiPix is a user friendly image capturing analysis and archiving system for video XYZ measurements 2 1 Project Database and its Security ooftware will be activated by inserting the provided dongle in a USB port of the computer where the software is installed This dongle will also be the key to database security The database can only be accessed if the correct dongle is used It is important to have a password protected Windows login to the PC where the software is installed 2 2 XYZ Measurement Database Components XYZ Measurement Database ieu x D 2 Menu Case Information re Inspection RK 512354 P Case 2
26. the Ruler will be frozen and a new dialog window will appear See image below Draw a line and enter the corresponding distance and current unit 1 000 um Ox 5 On the image click and hold to drag the desired distance Type in the distance and select the desired unit If imperial units are selected in the preferences imperial units are shown in the calibration window Selected calibration ratio will be seen on the status bar at the bottom of the Opti Pix window Note 1 Predefined magnifications cannot be calibrated Note 2 The last calibration used will always be stored upon closing the program and reloaded when starting the program Note 3 The selected calibration will always be saved together with the image 28 10 Measurement and Analysis 10 1 Measurements There are several ways measure on the picture It is possible to measure distances radius curve length areas and angles If no magnification has been selected the measurement results will be presented in pixels Before making measurements current magnification e g optical lens should be calibrated in the software See section Magnification and Calibration 29 e Distance ut To measure a distance click on the icon or select Measurements Distance Click and drag the distance to measure in the image 4C e Radius W To measure a radius there are two different methods either by selecting three points on the perimeter
27. the wheel of the mouse zooms in out using the cursor as centre of the image e Zoom In e Zoom in by clicking on the icon or select View Zoom In Hot key F4 e Zoom Out e Zoom out by clicking on the icon or select View Zoom Out Hot key F3 e Zoom to Fit Q Zoom to fit the screen size by clicking on the icon or select View Zoom to Fit Hot key F2 e Full Size To apply full size no digital Zoom select View Full Size Hot key F5 Full Screen Q Zoom to full screen by clicking on the icon or select View Full Screen Hot key F6 To close the full screen view press ESC The snap and the trigger functions will work as usual even under full screen view In Full Screen mode the user can browse through images by turning the wheel of the mouse A right click will give the option to exit Full Screen mode e Panning e To pan the image when zoomed in use the middle button of the mouse or click on the icon 34 11 Notes 35 12 System Requirements System recommendation Computer Intel Core 15 2 3 GHz or similar Recommended systems Station HP Pro 3500 MT Win7P or similar Laptop HP ProBook 4740s 17 3 HD LED or similar Memory 1GB or higher of RAM Recommended 2 GB Minimum 10 GB of Free Space Recommended 100 GB of Free Space Display Laptop 15 1600x900 HD PC 22 1920 x 1080 Full HD Recommended Laptop 15 1920x1080