Home
C-more Hardware User Manual
Contents
1. INSTALLATION AND CHAPTER WIRING In This Chapter SAPO EY GUS ING S scree cco E E E E E E E E ERNES 4 2 BENE OCI CCI ios so cocina taciecoransecipavesacansnectecsecesedcuavaatessmawepaecansantecesawapececsvasersenaanvseseseusers 4 3 EA9 T6CL R and EA9 T6CL Cutout DIMENSIONS ccscesscsscssceeccsscescsscescescees 4 4 EA9 T8CL Cutout Dimensions cccsccscceccsccsscessesceceeceececcescescnssassasencescescescesoes 4 5 EA9 T10CL Cutout Dimensions esesesessesesesesecssecseseseseososeseseseoeososeseseoesesecseseseseoeo 4 6 EA9 T12CL Cutout Dimensions esesesssssseseseseossecseseseseososeseseseseososeseseocsesscseseseseoee 4 7 EA9 T15CL Cutout Dimensions sesessssesesesesecssecsesesesessoseseseseoeososeseseoeseoecseseseseoeo 4 8 Mounting Clearances ssssssessssscsssesoseossossossossosecsecseoseossoseoseesessesscsecssosecsecsesseeseso 4 9 PASTS CL Der UNO eoero EE EE EE E EEES 4 10 A GU UNOS E A A E E E teameractanteeies 4 11 AGENCY APPIOV IS eseria iiep a EEE Ea O iE i a E 4 11 MANE USE aires E E TS 4 11 Providing Power to the Touch Panel sssossrecsrecrsseerecsnuiyniare eaer a 4 12 DER VV MPO AGIAN OA E E T E E E E E 4 12 PG VIN DAGTA een A EE E E A A EE E RS 4 12 C more LED Status Indicators 2 0 0 0 ccc cece ccc eccccccccecceccecceccecccecceccesceccecceescescesceces 4 13 Chapter 4 Installation and Wiring Safety Guidelines a A NOTE Products with CE marks
2. Wiring EA9 T15CL Cutout Dimensions The C more 15 touch panels are mounted into a cutout through the control cabinet and secured with eight 8 mounting clips The mounting clips are provided with the touch panel The mounting clips will insert into a series of slots around the rear perimeter of the touch panel Each clip has a tab that will mate to a slot The screw of each mounting clip needs to be tightened to the torque rating shown in the table below so that the gasket is compressed to form the proper seal between the panel and cabinet surface INCHES MM 2X 0 41 10 4 OUTER EDGE FRONT BEZEL OUTER EDGE CONTROL CABINET PANEL CUTOUT Enclosure Mounting Thickness Ranges and Mounting Clip Screw Torque ENCLOSURE MOUNTING THICKNESS RANGE MOUNTING BRACKET art mali Touch Enclosure Mounting Clip eey N ae Panel Size Thickness Range Screw Torque 0 039 0 20 inch 92 106 oz in 1 5 mm 0 65 0 75 Nm MOUNTING CLIP SCREW TORQUE H 8 l C mor E EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 Chapter 4 Installation and Wiring Mounting Clearances The following drawing shows the mounting clearances for the C more touch panel There should be a minimum of 4 inches of space between all sides of the panel and the nearest object or obstruction and at least 1 72 inches between the rear of the panel and the nearest object or obstruction Mounting Clip
3. or other similar flammability resistant rated cables Use cable specifications for your system that meet a recognized flame retardant standard i e UL IEEE etc including evidence of cable test certification i e tests certificate UL file number etc EA9 USER M Hardware User Manual 1st Ed Rev B 01 15 more i 4 1 Chapter 4 Installation and Wiring Wiring Guidelines cont d Providing Power to the Touch Panel e Connect a dedicated 12 24 VDC Class 2 power supply to the DC connector on the rear of the C more touch panel Connect the ground terminal to a proper equipment ground e or install a C more AC DC Power Adapter EA AC to the rear of the touch panel and connect an AC voltage source of 100 240 VAC 50 60Hertz to its AC connector e then turn on the power source and check the LED status indicators on the front and rear of the C more touch panel for proper operation See the LED Status Indicator diagram on the next page for reference DC Wiring Diagram DC CON Tightening Torque Power connector screw torque 70 4 oz in 0 5 Nm Power connector mounting torque 56 oz in 0 4 Nm 12 24 VDC Recommended DC Power Supply Ground AutomationDirect Part No PSC24 060 AC Wiring Diagram LZZLLLLL DDD LEZ Spe ME LAH gt HARES ERIC E RRC ERS Recommended AC Supply F
4. 10 and 12 i1 5 mm 0 45 0 55 Nm SCREW TORQUE Zam Alii N 5 lt Pa Touch Enclosure Mounting Clip 4 6 l C mor E EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 Chapter 4 Installation and Wiring EA9 T12CL Cutout Dimensions The C more 12 touch panels are mounted into a cutout through the control cabinet and secured with eight 8 mounting clips The mounting clips are provided with the touch panel The mounting clips will insert into a series of slots around the rear perimeter of the touch panel Each clip has a tab that will mate to a slot The screw of each mounting clip needs to be tightened to the torque rating shown in the table below so that the gasket is compressed to form the proper seal between the panel and cabinet surface INCHES MM 2X 0 40 12 57 102 319 3 IN D 10 2 e ee ee ee ee eee E ee ee eee OUTER EDGE FRONT BEZEL 10 22 259 6 OUTER EDGE 7 CONTROL CABINET ee eee PANEL CUTOUT Enclosure Mounting Thickness Ranges and Mounting Clip Screw Torque ENCLOSURE MOUNTING THICKNESS RANGE z z Touch Enclosure Mounting Clip MOUNTING emm g ig m m Es BRACKET Panel Size Thickness Range _Screw Torque g 40 0 039 0 20 inch 63 77 oz in MOUNTING CLIP 6 8 10 and 12 1 5 mm 0 45 0 55 Nm SCREW TORQUE EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 C mor i i 4 7 Chapter 4 Installation and
5. Front View Side View EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 C mor P i 4 9 Chapter 4 Installation and Wiring EA9 T15CL Derating If EA9 T15CL is mounted off the vertical plane facing upward the temperature shall be derated as shown below Other panels may be mounted at any angle without derating consideration 90 EA9I T15CL Angle 15 to 90 Angle 15 to 90 Temp 0 to 50 C Temp 0 to 50 C 15 Angle 0 to 15 Be Angle 0 to 15 Temp 0 to 45 C Temp 0 to 45 C T 0 DANAN ANANAMNANNANNNAAANANNANN UE Eh IHHHHHHHHI Ey poooa li A 90 EA9 T15CL Angle 45 to 90 with EA AC Temp 0 to 50 C Angle 45 to 90 Temp 0 to 50 C Angle 0 to 45 Angle 0 to 45 Temp 0 to 40 C Temp 0 to 40 C AT m leg HHH HAW HHH Du WA EHHH WAHAB Y J 0 4 10 l C more EA9 USER M Hardware User Manual 1st Ed Rev B 01 15 Chapter 4 Installation and Wiring Wiring Guidelines WARNING To minimize the risk of potential safety problems you should follow all applicable local and national codes that regulate the installation and operation of your equipment These codes vary from area to area and it is your responsibility to determine which codes should be followed and to verify that the equipment installation and operation are i
6. between the panel and cabinet surface INCHES MM 2K Oxo 7 46 7 9 189 5 2X 0 31 g o an Be ee ee ee eee OUTER EDGE FRONT BEZEL 5 51 140 0 OUTER EDGE CONTROL CABINET ee ee ee ee eee eee PANEL CUTOUT Enclosure Mounting Thickness Ranges and Mounting Clip Screw Torque ENCLOSURE MOUNTING THICKNESS RANGE ZDT LoL Uy MOUNTING nn lt BRACKET Panel Size__ Thickness Range Screw Torque g 40 0 039 0 20 inch 63 77 oz in MOUNTING CLIP 6 8 10 and 12 i1 5 mm 0 45 0 55 Nm SCREW TORQUE Touch Enclosure Mounting Clip a 2 l C mor E EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 Chapter 4 Installation and Wiring EA9 T8CL Cutout Dimensions The C more 8 touch panels are mounted into a cutout through the control cabinet and secured with four 4 mounting clips The mounting clips are provided with the touch panel The mounting clips will insert into a series of slots around the rear perimeter of the touch panel Each clip has a tab that will mate to a slot The screw of each mounting clip needs to be tightened to the torque rating shown in the table below so that the gasket is compressed to form the proper seal between the panel and cabinet surface INCHES MM OUTER EDGE l FRONT BEZEL 7 07 179 6 OUTER EDGE 7 CONTROL CABINET PANEL CUTOUT Enclosure Mounting Thickness Ranges and Mounting Clip Screw Tor
7. control cabinet that the panel will be mounted through securing the touch panel with the provided mounting clips tightening the screws to the appropriate torque rating to assure the gasket is sealing correctly and finally connecting the appropriate power source to the touch panel NOTE Each C more touch panel is provided with a cutout template to make marking the proper cutout size on the surface of the control cabinet that the panel will be mounted through a simple task This chapter covers the proper mounting of the touch panel and connecting power Once power is applied to the touch panel the user will want to read Chapter 5 on the System Setup Screens in order to set the internal time and date for the panel become familiar with the touch panel test features and check memory options Mounting Clips EA9 BRK EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 C mor gE i 4 3 Chapter 4 Installation and Wiring EA9 T6CL R and EA9 T6CL Cutout Dimensions The C more 6 touch panels are mounted into a cutout through the control cabinet and secured with four 4 mounting clips The mounting clips are provided with the touch panel The mounting clips will insert into a series of slots around the rear perimeter of the touch panel Each clip has a tab that will mate to a slot The screw of each mounting clip needs to be tightened to the torque rating shown in the table below so that the gasket is compressed to form the proper seal
8. n compliance with the latest revision of these codes Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards We do not guarantee the products described in this publication are suitable for your particular application nor do we assume any responsibility for your product design installation or operation If you have any questions concerning the installation or operation of this equipment or if you need additional information please call technical support at 1 800 633 0405 or 770 844 4200 This publication is based on information that was available at the time it was printed At Automationdirect com we constantly strive to improve our products and services so we reserve the right to make changes to the products and or publications at any time without notice and without obligation This publication may also discuss features that may not be available in certain revisions of the product Agency Approvals Some applications require agency approvals for particular components The C more touch panel agency approvals are listed below e UL Underwriters Laboratories Inc e CUL Canadian Underwriters Laboratories Inc e CE European Economic Union Marine Use American Bureau of Shipping ABS certification requires flame retarding insulation as per 4 8 3 5 3 6 a ABS will accept Navy low smoke cables cable qualified to NEC Plenum rated fire resistant level 4
9. perform their required functions safely and adhere to relevant standards as specified by CE directives provided they are used according to their intended purpose and that the instructions in this manual are adhered to The protection provided by the equipment may be impaired if this equipment is used in a manner not specified in this manual A listing of our international affiliates is available on our Web site http www automationdirect com WARNING Providing a safe operating environment for personnel and equipment is your responsibility and should be your primary goal during system planning and installation Automation systems can fail and may result in situations that can cause serious injury to personnel or damage to equipment Do not rely on the automation system alone to provide a safe operating environment You should use external electromechanical devices such as relays or limit switches that are independent of the PLC application to provide protection for any part of the system that may cause personal injury or damage Every automation application is different so there may be special requirements for your particular application Make sure you follow all national state and local government requirements for the proper installation and use of your equipment Plan for Safety The best way to provide a safe operating environment is to make personnel and equipment safety part of the planning process You should examine every aspect of the sys
10. que ENCLOSURE MOUNTING THICKNESS RANGE aa mmi I ouc nclosure ounting Clip all BRACKET Panel Size Thickness Range _Screw Torque g 40 0 039 0 20 inch 63 77 oz in MOUNTING CLIP 6 8 10 and 12 1 5 mm 0 45 0 55 Nm SCREW TORQUE EA9 T8CL Cutout Dimensions EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 C mor gE l 4 5 Chapter 4 Installation and Wiring EA9 T1OCL Cutout Dimensions The C more 10 touch panels are mounted into a cutout through the control cabinet and secured with eight 8 mounting clips The mounting clips are provided with the touch panel The mounting clips will insert into a series of slots around the rear perimeter of the touch panel Each clip has a tab that will mate to a slot The screw of each mounting clip needs to be tightened to the torque rating shown in the table below so that the gasket is compressed to form the proper seal between the panel and cabinet surface INCHES MM 2X 0 51 11 90 7 9 302 3 2X 0 31 _ 302 3 a j O S OUTER EDGE 7 FRONT BEZEL 226 3 OUTER EDGE 8 91 CONTROL CABINET PANEL CUTOUT Enclosure Mounting Thickness Ranges and Mounting Clip Screw Torque ENCLOSURE MOUNTING THICKNESS RANGE MOUNTING BRACKET Panel Size__ Thickness Range Screw Torque g 40 0 039 0 20 inch 63 77 oz in MOUNTING CLIP 6 8
11. tem to determine which areas are critical to operator or machine safety If you are not familiar with control system installation practices or your company does not have established installation guidelines you should obtain additional information from the following sources e NEMA The National Electrical Manufacturers Association located in Washington D C publishes many different documents that discuss standards for industrial control systems You can order these publications directly from NEMA Some of these include ICS 1 General Standards for Industrial Control and Systems ICS 3 Industrial Systems ICS 6 Enclosures for Industrial Control Systems e NEC The National Electrical Code provides regulations concerning the installation and use of various types of electrical equipment Copies of the NEC Handbook can often be obtained from your local electrical equipment distributor or your local library e Local and State Agencies many local governments and state governments have additional requirements above and beyond those described in the NEC Handbook Check with your local Electrical Inspector or Fire Marshall office for information 4 2 l C mor E EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 Chapter 4 Installation and Wiring Introduction The installation and wiring of the C more touch panels requires selecting an appropriate location for the touch panel laying out the cutout dimensions on the surface of the
12. use 3 0A time delay ADC p n MDL3 EA AC Tightening Torque Power supply cable torque 71 85 oz in 0 5 0 6 Nm Power connector mounting torque 71 85 oz in 0 5 0 6 Nm Mounting flange screw torque 57 71 oz in 0 4 0 5 Nm NOTE Power Fault features of the EA AC help protect data on an SD card during a power failure 4 12 l C more EA9 USER M Hardware User Manual 1st Ed Rev B 01 15 Chapter 4 Installation and Wiring C more LED Status Indicators User Defined Refer to online help Blinking file for further details Red Blinking Orange Blinking Green Power Off Normal CPU Run State Memory Error Blinking l Red Watchdog Timer Error oa OS Error Blinki eS Power Loss Detection Rear View EA9 USER M Hardware User Manual Ist Ed Rev B 01 15 more i 4 13
Download Pdf Manuals