Home
Lab-Line Multi Tube Rotator - User Manual
Contents
1. Multi Tube Rotator Model No 4632Q 4632 1CE 4632 1CECN 057 213 00 11 05 11 Table of Contents Safety Informationi ainia t 3 Alert Signals eis io 3 DEScnpioniszarzics ainsi aida eil 4 SPecItICAtIONS sisas rs ah aa ned ches ce ea aoe Met eae 5 Power IROQUIFCINGIIUS cuasi baina ia 5 Shaker MOON tadas stars ea 5 Shaker Speed Mc ica rt 5 Angle Of ROtATION arial li Iii ili 5 Platform DIMENSIONS aria tai iaa 5 UnIEDIMENSIONS asse ie aio is 5 Net Welles siena al ia 5 Declaration Of Contormity lu seria A ili iaia io 6 Environmental Conditions i eri 6 Unipacking and Installationi nine 7 SHIPPING Catastral a 7 Electrical Requirements iuci aa A at eee ti aa et ee 7 Location antartica id 8 Operati Maanta aaa eiaa e aea a aE e aged E e aE a A EOE 9 Panina CO sensa a R npc ine 10 NeutralizingiSpills anti 10 Replacing the POWEr SWITChi iaia aaa 10 Routine Gleaningi rara i lito a Oa eaea 10 Replacement Parts aio ateo A iaia 11 Ordering Procedure acatar rad 12 Two Year Limited Warranty tal 13 Safety Information Alert Signals gt BP MODE Warning Warnings alert you to a possibility of personal injury Caution Cautions alert you to a possibility of damage to the equipment Note Notes alert you to pertinent facts and conditions Hot Surface Hot surfaces alert you to a possibility of personal injury if you come in contact with a surface during use or for a period of time after us
2. instructions for the product mishandling contamination overheating modification or alteration of the product by any customer or third party or iii use of replacement parts that are obtained from a party who is not an authorized dealer of Thermo Scientific prod ucts Heating elements because of their susceptibility to overheating and contamination must be returned to the factory and if upon inspection it is concluded that failure is due to factors other than excessive high tempera ture or contamination the manufacturer will provide warranty replacement As a condition to the return of any product or any constituent part thereof to the factory it shall be sent prepaid and a prior written authorization from the manufacturer assigning a Return Materials Number to the product or part shall be obtained IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO ANY PARTY FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES OR FOR ANY DAMAGES RESULTING FROM LOSS OF USE OR PROFITS ANTICIPATED OR OTHERWISE ARISING OUT OF OR IN CONNECTION WITH THE SALE USE OR PERFORMANCE OF ANY PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT TORT INCLUDING NEGLIGENCE ANY THEORY OF STRICT LIABILITY OR REGULATORY ACTION For the name of the authorized Thermo Scientific product dealer nearest you or any additional information contact us North America USA Canada 1 866 984 3766 866 9 THERMO www thermo com Europe Austria 43 1 801 40 0 Bel
3. 03 Amps 4 0 Watts Shaker Motion Bi directional rotation Shaker Speed fixed 30 revolutions per minute Angle of Rotation 20 from the horizontal plane Platform Dimensions 8 13 16 W x 5 3 8 D 22 5 x 13 8 cm Unit Dimensions 6 7 8 W x 8 3 8 D x 8 H 17 x 21 3 x 20 3 cm Net Weight 6 Ibs 3 kg SPECIFICATIONS Declaration of Conformity For 220 to 240 volt CE models only We hereby declare under our sole responsibility that this product conforms with the technical requirements of the following standards EMC EN 61000 3 2 Limits for harmonic current emissions EN 61000 3 3 Limits for voltage fluctuations and flicker EN 61326 1 Electrical equipment for measurement control and laboratory use Part General Requirements Safety EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part General Requirements EN 61010 2 010 Part Il Particular requirements for laboratory equipment for the heating of materials EN 61010 2 051 Part Il Particular requirements for laboratory equipment for mixing and stirring per the provisions of the Electromagnetic Compatibility Directive 89 336 EEC as amended by 92 31 EEC and 93 68 EEC and per the provisions of the Low Voltage Directive 73 23 EEC as amended by 93 68 EEC The authorized representative located within the European Community is Thermo Fisher Scientific 419 Sutton Road Southend On Sea Essex SS2 5PH Unit
4. e Risk of Electric Shock Disconnect unit from power source before removing cover Your Thermo Scientific Lab Line Multi Tube Rotator has been designed with function reliability and safety in mind It is your responsibility to install it in conformance with local electrical codes It is most important that the user follow installation instructions exactly as written Failure to do so is likely to lead to improper operation erroneous calibrations and possible damage to the equipment Do not attempt operation without this information Description The model 4632Q Multi Tube Rotator mixes the contents of blood tubes and other vessels making it ideal for use in hematology blood chemistry and other laboratory applica tions where a continuos gentle motion is necessary The mechanical action of the unit provides a circular motion coupled with a rocking pattern that keeps liquids and solutions gently mixed without the potential for shearing or other damage The portable lightweight metal body is durable and easy to clean The rotator s compact size permits easy trans portability and use in areas with limited space The white silicone rubber non skid double sided platform surface holds 7ml 10ml or 15ml tubes firmly in place The rock er s four rubber feet provide additional stability Specifications Power Requirements Model 46320 120 VAC 60 Hz 0 03 Amps 4 0 Watts Model 4632 1CE amp 4632 1CECN 220 240 VAC 50 Hz 0
5. ed Kingdom Copies of the Declaration of Conformity are available upon request Unit s Environmental Operating Conditions Pollution Degree Installation Category i Altitude 2000 Meters MSL Mean Sea Level Humidity 80 maximum non condensing Electrical Supply 120VAC or 240VAC Voltage Tolerance 10 of normal rated line Temperature 15 C to 40 C Product Usage This product is intended for use indoors only Unpacking and Installation Note Leave unit disconnected when not in use Shipping Carton This should be inspected upon delivery When received carefully examine for any shipping damage before unpacking If damage is discovered the delivering carrier should both specify and sign for the damage on your copy of the delivery receipt Open the carton carefully making certain that all parts are accounted for before packaging materials are discarded after unpacking if damage is found promptly report it to the carrier and request a damage inspection promptly IMPORTANT Failure to request an inspection of damage within a few days after receipt of shipment absolves the carrier from any liability for damage you must call for a damage inspection promptly Electrical Requirements Model 4632Q requires a 120 VAC 60 Hz power source It is supplied with a 3 wire line cord It should be plugged into an outlet designed for 3 prong plugs If an extension cord is used it also should be the 3 wire grounded type F
6. gium 32 2 482 30 30 France 33 2 2803 2180 Germany national toll free 08001 536 376 Germany international 49 6184 90 6940 Italy 39 02 02 95059 434 254 375 Netherlands 31 76 571 4440 Nordic Baltic countries 358 9 329 100 Russia CIS 7 812 703 42 15 Spain Portugal 34 93 223 09 18 Switzerland 41 44 454 12 12 UK Ireland 44 870 609 9203 Asia China 86 21 6865 4588 or 86 10 8419 3588 India toll free 1800 22 8374 India 91 22 6716 2200 Japan 81 45 453 9220 Other Asian countries 852 2885 4613 Countries not listed 49 6184 90 6940 or 33 2 2803 2180
7. h solution of warm water and a mild detergent Surfaces should them be wiped with a second cloth dampened with clean water and dried thor oughly For cleaning in the event of a spill or dried contamination the Neutralizing Spills procedure shall be followed Do not use abrasive cleaners on any surfaces as damage to surface finish will result Description Bearing Bellows Cordset 4632Q Cordset 4632 1CE Cordset 4632 1CECN Fuse 0 5 Amp Motor 120V 60 Hz Motor 240V 50 Hz Rotator Spindle Rubber Feet 4 Rubber Mat Switch Wiring Schematic 120V unit Part Number 140 258 00 790 408 00 470 187 00 CRX77 CRMX10 330 291 00 370 317 00 370 318 00 659 058 00 790 214 00 790 405 00 440 359 00 229 095 00 Replacement Parts Ordering Procedures Please refer to the Specification Plate for the complete model number serial number and series number when requesting service replacement parts or in any correspon dence concerning this unit All parts listed herein may be ordered from the Thermo Scientific dealer from whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer cannot handle your request then contact our Customer Service Department at 563 556 2241 or 800 553 0039 Prior to returning any materials please contact our Customer Service Department for a Return Materials Authoriza
8. nder war ranty before consulting your distribu tor After the warranty period such consultation is still advised especially when the repair may be technically sophisticated or difficult If assistance is needed beyond what the distributor can provide please call the customer service department at 1 800 553 0039 No merchandise how ever should be returned without prior approval Caution Disconnect plug from electrical outlet before attempting any maintenance or repair of this unit Neutralizing Spills In the event of any spills on the surfaces of the unit carry out appropriate neutralization procedures and wiped off using a clean cloth dampened with a cleaning solution made of warm water and a mild detergent Surfaces should then be wiped with a second cloth dampened with clean water and dried thoroughly Do not use abrasive cleaners on surfaces Replacing the Power Switch Replacing the power switch requires removal of the bot tom cover Turn unit over and remove 4 screws holding the bottom cover and lift cover from the housing POWER SWITCH Disconnect wiring from switch Grasp the switch on its top and bottom depress the locking spring sufficiently to free the switch from the unit Withdraw from the front Reverse procedure to install new switch Replace bottom cover and tighten the 4 screws previously removed Routine Cleaning Cleaning of the surfaces should be performed using a clean cloth dampened wit
9. ons and similar items Warning Protection provided by the equipment may be impaired if not correctly used in the manner specified Note If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Operation Control Panel le ol o Choose one side of platform mat that matches the size of the vessels being used Place tubes on rubber mat and secure them by firmly pressing them between supports Vessels may be changed while platform is rotating Arrange the tubes so as to avoid any possibility of contact with each other while the rotator is in motion Plug power cord into appropriate three prong grounded outlet whose characteristics match those on the rotator s data plate Turn power on by placing power switch in the position Green LED should light In the event that gases may be emitted from any reactions taking place the rotator should be placed in a properly vented hood Observe all rules of your organization or labora tory regarding the wearing of safety gloves glasses and protective clothing After mixing action has completed turn power off by placing power switch in the O position Green LED should be off Remove all vessels To lengthen life of unit it is recommended that rotator be disconnected from its power source when not in use Maintenance Y Note Make no attempt to service or repair a Thermo Scientific product u
10. or an outlet designed to accept 2 prong plugs ungrounded it is required that a qualified electrician replace the outlet with a new grounded type Models 4632 1CE and 4632 1CECN require 220 240 VAC 50 Hz power source 4632 1CE is furnished with a European cord set and 4632 1CECN is furnished with a China cord set If a plug must be installed use only the 3 prong grounded type rated for the unit load requirements and matching the power outlet Make sure the green ground wire is secured to the plug ground terminal UNPACKING AND INSTALLATION Note Position rotator so that in case of emergency the plug is within easy to be quickly disconnected from the power outlet Location For optimum performance place the unit on a level stable surface and in an area free from drafts extraneous heat sources and vibration Be sure to provide clearance on all sides so as to avoid contact of the moving platform with any surrounding equipment or objects Do not use in a room with a temperature higher than 40 C Do not use in a room with a temperature lower than 15 C Do not use in a damp atmosphere gt P P Warning Do not use in the presence of flamma ble or combustible materials or explo sive gases fire or explosion may result causing death or severe injury Warning Do not operate rotator without plat form in place Exposed rotating parts can be a hazard to fingers and or clothing such as shirt cuffs ties but t
11. tion number RMA Material returned without an RMA number will be refused One Year Limited Warranty This Thermo Scientific product is warranted to be free of defects in materials and workmanship for one 1 year from the first to occur of i the date the product is sold by the manufacturer or ii the date the product is purchased by the original retail customer the Commencement Date Except as expressly stated above the MANUFACTURER MAKES NO OTHER WARRANTY EXPRESSED OR IMPLIED WITH RESPECT TO THE PRODUCTS AND EXPRESSLY DISCLAIMS ANY AND ALL WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF DESIGN MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE An authorized representative of the manufacturer must perform all warranty inspections In the event of a defect covered by the warranty we shall as our sole obligation and exclusive remedy provide free replace ment parts to remedy the defective product In addition for products sold within the continental United States or Canada the manufacturer shall provide free labor to repair the products with the replacement parts but only for a period of ninety 90 days from the Commencement Date The warranty provided hereunder shall be null and void and without further force or effect if there is any i repair made to the product by a party other than the manufacturer or its duly authorized service representa tive ii misuse including use inconsistent with written operating
Download Pdf Manuals
Related Search
Related Contents
fulltext - DiVA Portal Aperçu du contrôleur MTS 793 Emerson Fisher easy-e ED Instruction Manual CD Player User Manual Addictive Synth user manual - VirSyn Software Synthesizer PCIe4-SIO8BX2 - General Standards Corporation Mode d`emploi SPIP DURO ROCK. S.A. de C.V. Copyright © All rights reserved.
Failed to retrieve file