Home

TimeLox User manual elevator controll

image

Contents

1. 29 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b ELEVATOR QUTPLUT MG 1 128 1 SET UP DONE FOR CLEAR TIME Picture 32 8 Press Enter You will get the screen shown in picture 33 At Room from enter the first room in the room interval that is to be included for this output Press Enter At Room to enter the last room in the room interval that is to be included for this output Press Enter ELEVATOR ROOM FROM 70 ROOM TO COMMON ROOM 1 MO COMMON ROOM 2 MO COMMON ROOM 3 MO COMMON ROOM 4 MO COMMON ROOM S MO COMMON ROOM 6 MO COMMON ROOM 7 MO COMMON ROOM 8 MO CLEAR Picture 33 9 The text Change 1 8 will appear below common room 8 For each common room that is to be included enter the number of the common room at Change 1 8 and confirm with Enter The chosen common rooms will be marked with Yes see picture 34 ELEVATOR ROOM FROM 101 ROOM TO 110 COMMON ROOK 1 MO COMMON ROOM 2 MO COMMON ROOM 3 YES COMMON ROOM 4 MO COMMON ROOMS YES COMMON ROOM 6 MO COMMON ROOM 7 MO COMMON ROOM MO CHANGE 1 37 CLEAR Picture 34 30 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described produ
2. Example 2 This example is only applicable for MC A company hires all three floors in an office building but each employee may only access the floor he is working at The company management can however access all floors e inthis example the relays outputs are connected to the elevator control panel e When a card which opens relay 1 is inserted in the elevator reader the push button for floor 1 on the elevator control panel will lighten up e Access to door 1001 Elevator button 1 actually means access to floor 1 access to door 2001 Elevator button 2 means access to floor 2 etc e Access to section 1 gives access to floor 1 and all doors on floor 1 3001 3002 3003 3004 3005 3006 Floor 3 The company Relay 3 3001 Section 3 YES Relay 2 2001 Section 2 YES Relay 1 1001 Section 1 YES HCU 2001 2002 2003 2004 2005 2006 Floor 2 The company 1001 1002 1003 1004 1005 1006 Floor 1 The company Picture 46 When setting up relay output 1 in the HCU according to 7 1 Initiating elevator reader and elevator reader relays the door number entered see picture 47 should be 1001 Also section 1 should be included when setting up relay 1 For relay 2 door 2001 and section 2 should be included For relay 3 door 3001 and section 3 should be included 40 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservat
3. 302 El Elevators ground floor Expiration time 11 29 2005 1200AM gt Time schedule none gt l BM Time schedule description o he 101 a 102 103 104 105 Options Hi p ar I Clear fields E E IY Print receipt Check all Uncheck all More Counters Close Picture 20 Cancel cards and Power Down cards will function as normally Blocking cards will block one or more user groups from certain relays see 4 3 3 Blocking a user group from an elevator reader relay for details Stand Open cards will set one or more relays in stand open mode see 4 3 4 Setting an elevator reader relay in stand open mode for details One Time cards will not have the one time function in the elevator reader but function as ordinary access cards until they expire Note Emergency cards will activate all outputs connected to the elevator reader 4 3 2 Assigning common access For floors that should be accessed by all guest cards for example a restaurant floor the concerned output must be set up to accept all cards in the guest room range see 4 1 1 Setting up an elevator reader relay for details It is also possible to set up 28 common rooms for each output see 4 1 1 Setting up an elevator reader relay for details Restaurants etc which should be accessed by all guests can be set up as common rooms in the DC One software common rooms are all doors that have been set up to be of type Guest Common or PMS Common see User
4. 4 7 2005 12 00 AM E Development G Elevators Function po L Floor relay f Until nest use a O re Bi Loi EP IOOr 3 relay amp For hours H o Finance H Logistics a mee Uncheck all cine Picture 30 1 Double click on Stand Open under the Cards tab in the navigation window 2 Select a card holder by clicking the button double click on a name or mark the name and click Select 3 Choose the expiration time of the card enter the number of days for which the card shall be valid or mark the E button next to the Expiration time field and mark a date in the calendar or enter a date manually The chosen date will appear at Expiration time the number of days will change accordingly 4 For elevator reader relays only the default type Until next use is applicable at Function 5 At Doors check the relay s you want to set in stand open mode in this example floor 3 relay and also the ordinary doors library and lunch room Click on the plus sign in front of a door area to expand the area 6 Click on Make Card or press F2 Insert a card in the encoder Insert the card in the elevator reader The concerned relays will be set in stand open mode The relays will be set in stand open mode at the first insertion of the stand open card and be reset on the second insertion Note The No of days regards the card s validity not the validity of the function 21 Timelox AB 20
5. Timelox AB makes a reservation against changes in the performance of the above described product 865 253b EIT loxi General Doors Card holder Burton Tim BI V Basement User group Day staf oe No of days az Restaurant sala hal 4 7 2005 12 004M El M Aee ground floor First floor relay Function TOON Until next use eee As floor relay irst floor Until time is 5 101 C For hours O ies Check all Uncheck all Close Picture 22 1 Double click on Stand Open under the Cards tab in the navigation window 2 Select a card holder by clicking the button double click on a name or mark the name and click Select 3 Choose the expiration time of the card enter the number of days for which the card shall be valid or mark the bd button next to the Expiration time field and mark a date in the calendar or enter a date manually The chosen date will appear at Expiration time the number of days will change accordingly 4 For elevator reader relays only the default type Until next use is applicable at Function 5 At Doors check the relay s you want to set in stand open mode in this example second floor relay and also the ordinary door lounge Click on the plus sign in front of a door area to expand the area 6 Click on Make Card or press F2 Insert a card in the encoder Insert the card in the elevator reader The concerned relays will b
6. e E EEA ATS Il ALD SOLAN Up AIETE VATOV TEO UET rE OEE BRUNA Gs A RE rth 12 4 2 Initiating elevator reader and elevator reader relayS cccceesssssscceeceesesnseeececcesesenseceeccesseseaeaeeesseesesaeaeesees 14 ADA TSUNE OM AON COT Goa coousoeny cts use dvavugnascvaasansenstnacsl A E A A ee 15 ADD mitatine he elevator TAG EP errora sra EENES NTE AEE E OT E AEN NO I5 ASSAD AUN A IN rA T E A T E N A N E E R 16 4 3 1 Assigning individual access With EXAMPLES cccccccsecsssccscccecececeecceesessessssssneceeseeeeeeseeeeeeseseeeessnsaaeaeeeeees 16 A e PASSE PUNE COMMON ACCESS assis sa sas AE A AEE T EEA AOS 17 4 3 3 Blocking a user group from an elevator reader relay ccccscscsseccsscccccceccceceeeeeeeseeessesssesssaseaaaeeeeeeeeeeeseeeees 17 4 3 4 Setting an elevator reader relay in stand open mode oicicssecsscccccccccccccccccceceeeeseeeeseesusssaaaeeaeeeeeeeeseeseseseeeees I8 dak oere UNCON S ea A ET a E E Joel tees E 19 LAT ROT OUl eher e A a a ea ER 19 EAD POWER ODT rnn easel A E A E NaeN nT aes 20 5 Initiation daily use and Service functions in TC sssssccceeessssocccccesesosocecescsssosooeceesssososoccesssososeseceessssoseeeeseess 21 Sere Ari SOL ind at on In TC EA A E 21 Jed SCUIN UP CNClEV VOLT CODCH TOLAN Sirari de ire EEEE AENEA SRRA OESE A A tein 2 Del 2 SCHING UP GN CLEVQLOL TCOQCT ieres aA EEOAE AEA A Sapa iussa heen Race NSA 22 5 2 Initiating elevator reader and elevator reader TelayS ic cssvcasceses snasdcasseds
7. fill in the fields accordingly 6 Click on Make Card or press F2 Insert a card in the encoder 4 2 2 Initiating the elevator reader Insert the card into the elevator reader at the exact time and date that were chosen when the initiation card was issued if time and date are to be set since that specific time will be set in the elevator reader There is a ticking sound while the information is being transferred to the elevator reader Wait for the signal before pulling the card or the operation will not be successful An initiation will be stored as at least two events in the event list to prevent tampering with the time in the elevator reader one event before the initiation and one event after and possibly some other events if the initiation causes the door unit status to change Note The initiation card can only be used once to avoid that two elevator readers are given the same identity 15 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 4 3 Daily use 4 3 1 Assigning individual access with examples Guest cards of different types Guest cards Joiner cards etc will give access to an elevator reader relay output corresponding to for example a floor if the room that is assigned for the card is included in the relay room interval see 4 Setting up an elevator reader relay for
8. is a ticking sound while the information 1s being transferred to the card Wait for the signal before pulling the card or the operation will not be successful One read out card can be used in several elevator readers When the card is full a signal will alert the user Transferring the information to the Timelox PC for processing 1 Click on the icon Read Events from Card or if applicable Read Parameters from Card and insert the card in the encoder 2 Click Read card to see the fetched events or parameters The events parameters can only be fetched from the card once then they are erased from the card they can however be read out from the door unit again 5 4 2 Power open It is not possible to perform a power open on an elevator controller if there is a failure in the elevator controller s external power supply 28 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 6 Initiation daily use and service functions in 2300Win 6 1 Initiating elevator reader and elevator reader relays When the elevator controller has been mounted and connected according to chapters 2 and 3 the elevator reader relays are set up as outputs in the handheld communication unit HCU When the elevator reader is initiated with the HCU the connected relays will automatically be initiated as well Note V
9. manual TimeLox DC One Art No 865 100 for details Note The common rooms that are assigned to an output will only give access to magnetic cards 4 3 3 Blocking a user group from an elevator reader relay One or more user groups can be blocked from certain elevator reader relays for example corresponding to certain floors This is done by issuing a blocking card for the relays that are to be blocked Note The DC One system can in total have 200 user groups 17 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b H Blocking Card E 2 0 x General Doors Card holder Hanson Susan Ey V Basement Garage User group Da staff J Lano No of days fiso Restaurant Expiration time 9 10 2005 12 004M Sauna M4 Elevators ground floor v First floor relay Block User groups O Second floor relay Day staff a Guest H 0 First floor C Maintenance 101 p C Manager O 102 V Night staff 103 104 105 106 min x Check all Uncheck all Check all Uncheck all cos Picture 21 1 Double click on Blocking under the Cards tab in the navigation window 2 Select a card holder by clicking the EI button double click on a name or mark the name and click Select 3 Choose the expiration time of the card enter the n
10. the performance of the above described product 865 253b 5 1 2 Setting up an elevator reader 1 Double click on Doors under the Lists tab in the navigation window 2 Click Add to add an elevator reader A dialog as in the example in picture 24 is shown E General General Options gt _ ee prea Type of door aR Gig sa Ry Indication Name Main elevator Area Elevators Add Description Open time 4 seconds Relay outputs DOO amp WM hE Picture 24 3 At Type of door choose Elevator Reader Enter a Name for the elevator reader 5 At Area choose what door area the door shall belong to should there not be a suitable one make a new door area by clicking Add 6 If desired enter a Description 7 If applicable modify the Open time the default is 4 seconds the open time can be 1 30 seconds 8 At Relay outputs mark a concerned output and click Select You will get a dialog where the elevator reader relays that have been set up will be shown see the example in picture 25 i Select Elevator Reader Relay i X Elevators Elevator Floor 1 relay Elevators Picture 25 27 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 9 Mark the appropriate relay and click OK 10 Repeat steps 8 9 for all concerned relays The result
11. the employee inserts his card in the elevator reader the push button for floor 1 on the elevator control panel will lighten up When the employee should access his own room etc he inserts his card in this particular door 4 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 7 3 Service functions 7 3 1 Read out It is possible to read out the access list from an elevator reader it is however not possible to see which of the outputs that have been opened The elevator reader can store 100 events 1 Go to 2 2 1 Read out 100 in the HCU press Enter to reach the Main menu press 2 Door unit menu and Enter press 2 Read out menu and Enter press 1 Read out 100 2 Follow the instructions on the HCU screen 7 3 2 Power open It is not possible to perform a power open on an elevator controller if there is a failure in the elevator controller s external power supply 42 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b Appendix Quick reference of technical data Cut out for elevator reader WxH 111 5 x 80 mm 4 7 16 x 3 3 16 inches Cut out for reader slot WxH 55 5 x 5 5 mm 2 3 16 x 1 4 inches Dimensions elevator reader WxH
12. the first relay module to terminal 2 on the second relay module 2 Connect terminal 4 on the first relay module to terminal 4 on the second relay module 3 Connect terminal 13 on the first relay module to terminal 13 on the second relay module 4 Connect terminal 14 on the first relay module to terminal 14 on the second relay module 5 The remaining terminals on each relay module 5 12 and 17 24 are connected in pairs Each pair forms a relay output which can be connected to the elevator s control system The pairs are 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 6 Set the address selector 25 on the second relay module at address 1 The address selector on the first relay module should still be at address 0 7 If additional relay modules should be added repeat steps 1 5 The address selector on the third module should be at address 2 etc Important Remove the terminating resistor 26 on all relay modules except for the last one counted from the reader Note Each address selector must have a unique address and the addresses should come in a consecutive order without any gaps in between that is 0 1 2 etc Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 4 Initiation daily use and service functions in DC One 4 1 Prepari
13. to terminal 4 on the relay module 4 Connect terminal 1 on the elevator reader to terminal 2 on the relay module 5 Connect terminal 1 on the relay module to the positive terminal on an external power source regulated voltage in the range 12 24V DC 6 Connect terminal 3 on the relay module to the negative terminal on an external power source regulated voltage in the range 12 24V DC 7 The remaining terminals on the relay module 5 12 and 17 24 are connected in pairs Each pair forms a relay output which can be connected to the elevator s control system The pairs are 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 Important Make sure that the address selector 25 on the relay module has got the address 0 9 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 3 3 Connecting additional relay modules DC One TC 2300Win MC EC Important Use the same external power supply for the elevator reader and all relay modules i e connect as described in section 3 1 or 3 2 depending on product and 3 3 This is to make sure that the ground is common for the elevator reader and all relay modules If more than one relay module should be used connect them as below Relay module 1 Relay module 2 Picture I 1 Connect terminal 2 on
14. used aq wW Electric door strike or other relay device Picture 1 Connect terminal 4 on the elevator reader to terminal 14 on the relay module 2 Connect terminal 3 on the elevator reader to terminal 13 on the relay module 3 Connect terminal 2 on the elevator reader to terminal 4 on the relay module 4 Connect terminal 1 on the elevator reader to terminal 2 on the relay module 5 Connect terminal 1 on the relay module to the positive terminal on an external power source regulated voltage in the range 12 24V DC 6 Connect terminal 3 on the relay module to the negative terminal on an external power source regulated voltage in the range 12 24V DC 7 The remaining terminals on the relay module 5 12 and 17 24 are connected in pairs Each pair forms a relay output which can be connected to the elevator s control system The pairs are 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 Important Make sure that the address selector 25 on the relay module has got the address 0 7 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 3 2 Connecting the elevator reader to a relay module 2300Win MC EC Important Use the same external power supply for the elevator reader and all relay modules i e connect as des
15. will be as in the example in picture 26 Mi door Details 5 x General General KS Opti 2 rae 4 Type of door Elevator Reader Indication Mame Main elevator Area Elevators Add Description Open time E seconds Relay outputs Floor 1 relay Floor 2 relay Floor 3 relay n a n a n a r nd ja D 07 N S oo e Remove New Save Cancel Picture 26 Note The tabs Options Advanced and Indication are not applicable for elevator reader relays 11 Click New or Save or Update if an existing elevator reader was modified 5 2 Initiating elevator reader and elevator reader relays The elevator reader is initiated with an initiation card The initiation can be performed either before or after the system ID is set When an elevator reader is initiated parameters such as the calendar the date and time if that 1s chosen elevator reader number opening time opening mode and cancel list are transferred Also parameters for the elevator reader relays that have been set up for the elevator reader are transferred number opening time room interval and common room s for each relay Note If only time and date are to be set this can be done with the HCU This may be easier than using the initiation card for setting the time and date since the card must for this purpose be inserted at an exact time either directly after issuing it or at a certain time defined when issuing the c
16. 05 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 5 4 Service functions 5 4 1 Read out It is possible to read out the access list from an elevator reader it is however not possible to see which of the outputs that were opened The elevator reader can store 100 events Read out with HCU 1 Go to the applicable HCU menu 2 2 1 Complete LockLog 2 2 2 Error LockLog 2 2 3 Access LockLog or 2 2 4 Parameters press Enter to reach the Main menu press 2 Door unit menu then press 2 Read out menu and your choice for example 1 Complete LockLog 2 Follow the instructions on the HCU screen Read out with card Issuing a read out card or read out card advanced in the TC software 1 Double click on Read out or if applicable Read out Advanced under the Cards tab in the navigation window 2 Make the appropriate choices enter the appropriate fields etc in the card dialog 3 For cards of type Read out Advanced it is possible to read only new events i e events that have not been marked as read in the elevator reader In this case check Only new events In order to read only new events check Mark events as read 4 When all information has been entered click on Make Card or press F2 Insert a card in the encoder Making a read out 1 Insert the card in the elevator reader to make a read out there
17. C or 2A 30VDC resistive 3 1 Connecting the elevator reader to a relay module DC One and TC Important Use the same external power supply for the elevator reader and all relay modules i e connect as described in section 3 1 and 3 3 This is to make sure that the ground is common for the elevator reader and all relay modules Elevator reader Relay module I pe O Four pole connector J9 ABLE 9oOO 00 00 08 13 14 15 16 17 18 19 20 21 22 Four pole connector J3 J9 and J3 are located on the reverse side The pictures of the elevator reader and the of the card relay module are not of the same scale Picture 7 J9 3 is connected to J9 4 when the door is closed J9 Relay output see detailed normal state see picture 8 No connection description to the right between J9 2 and J9 3 J3 4 B ji RS485 J9 3 is connected to J9 2 when the 3 A door is unlocked during the open time that is set up for the reader see 2 f Regulated voltage in 4 1 2 Setting up an elevator reader 1 the range 12 24V DC for details No connection between J9 3 and J9 4 See picture 8 Note J9 and J3 are Timelox designations which are not 6 visible on the elevator reader J9 1 normally not used see picture 8 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b qj 1 Not
18. F 180 clip Picture 5 The mounting rack with relay modules can be fastened on a standard DIN rail 4 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 68 2 3 4 100 3 15 16 Measures in mm inches Picture 6 The relay module is 75 mm 3 inches high with mounting rack and DIN rail and 52 mm 2 1 16 inches with mounting rack only 5 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 3 Electrical specification e The elevator controller needs an external power supply of regulated voltage in the range 12 24 V DC e The maximum current consumption for the elevator reader is 100 mA continuously e The maximum current consumption for each relay module is 100 mA continuously e The elevator reader can be expanded with up to 16 relay modules each with 8 outputs giving a maximum of 128 outputs e The electrical standard for the serial interface connecting the different modules is RS 485 e If the distance between the reader and the first relay module is more than 20 metres the cable should be shielded The shield should be connected to protective ground at one end Note The maximum load of the relay outputs is 0 6A 125VA
19. Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 4 2 1 Issuing an initiation card iolx General x _ A Doos sSh_SpaSJ qog gt smw gt Card holder Burton Tim El l Basement User group Day staff o Ho of days fiso E spiration time 3710 2005 12 00 AFl S Elevators ground floor Elevator reader annex 1 Function bo Elevator reader annex 2 Do not set time and date in lock 7 Elevator reader main elevator Set time and today s date in lock E First floor i Set time and date in lock _s 101 Time fi5 00 Initialize door Date fi 2 10 2004 Elevator reader main elevator w Picture 18 1 Double click on Initiation under the Cards tab in the navigation window 2 Select a card holder by clicking the button double click on a name or mark the name and click Select 3 Choose the expiration time of the card the default value is one day enter the number of days for which the card shall be valid or mark the E button next to the Expiration time field and mark a date in the calendar or enter a date manually The chosen date will appear at Expiration time the number of days will change accordingly 4 Mark the elevator reader that you want to initiate it will appear in the text field Initiate door 5 Choose one of the three date time options and
20. USER MANUAL Elevator controller DC One TC 2300Win MC EC User manual Elevator controller for DC One TC 2300Win MC EC Table of contents Ds TMG OUUCTION PA E E E E E E E E EAA O E EN 2 Dia AEA AUO OT E EN A AE E E A E IE E A EEA E SE E A EE EE OA 3 E CUR OUP UC UM aa a E aee eehe eeaian aca ere mmdad nar enee ose tasaat 3 ZA MOUNN OV CLV E Woa e voude svinsse cccedeanedaaueaiteaad de tenses Mane selon asueben udcteaniiase ctaw A N 3 D2 BACKUP DAMCLY waicnntionuiat sau siatastaceduadacalsuasaeiaceshapsuactecGiaeeadeseeaustscacsuaesaabscunessanioss fouctd ce haan sasecaeeacateudasseeacetalaete ts 4 Di cs Clay OCU Me oe cates chess e ese A Sie ano T dudoe sangre dete te a tee here 4 3 Electrical specification seisoessa ao vensenssasenancaveseateusceseucsasosascaeadssestadescsdtsaad stendeassatesusecsenes 6 3 1 Connecting the elevator reader to a relay module DC One and TC ecccssssscecceeseesesneceeeeessnseseaaees 6 3 2 Connecting the elevator reader to a relay module 2300Win MC EC cccccccsesessecceceeesesesneceeeeseesesseneees 8 3 3 Connecting additional relay modules DC One TC 2300Win MCTEC ccccccccccceesessseeceeecessessseeeeeeeseees 10 4 Initiation daily use and service functions in DC ONEC ccccsssccsssssscccsssssssssscscsssssssssssscssssssssssssssssssosees 11 dl PTC DALiM S TOT MMA OU eer eE nica aaectapichan alse aE bea teiuat E ied E E ERARE 11 Al 1 Stine upan elevatortedder TEIGY oiire E AE Ea a
21. according to chapters 2 and 3 the elevator readers and elevator reader relays are set up as doors in the TC software After this is done an initiation card is issued in TC for the elevator reader When the elevator reader is initiated the connected relays will automatically be initiated as well 5 1 1 Setting up an elevator reader relay Each elevator reader relay is set up as a door 1 Double click on Doors under the Lists tab in the navigation window 2 Click Add to add an elevator reader relay A dialog as in the example in picture 23 is Shown lox General General Options e l Advanced Type of door levator Header Relay i ndication Mame Fioor1 ALBA Elevators Add Description P Open time p seconds Picture 23 3 At Type of door choose Elevator Reader Relay Enter a Name for the elevator reader relay 5 At Area choose what door area the door shall belong to should there not be a suitable one make a new door area by clicking Add 6 If desired enter a Description 7 If applicable modify the Open time the default is 4 seconds the open time can be 1 30 seconds Note The tabs Options Advanced and Indication are not applicable for elevator reader relays 8 Click New or Save or Update if an existing elevator reader relay was modified 21 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in
22. ard depending on whether Set time and today s date in lock or Set time and date in lock was chosen when issuing the card see picture 27 23 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 5 2 1 Issuing an initiation card loj x General Doors Card holder Larsen Mark A Common areas Conference rooms User group Finance Development No of days 2 Elevators ene Elevator building B Expiration time 3711 2005 12 00 AM Elevator building C Main elevator Function Entrances C Do not set time and date in lock tl Finance Set time and today s date in lock Logistics Set time and date in lock EH Marketing x Time 3 00 PM Initiskee door Date 3 11 2009 Maw cine _ Picture 27 1 Double click on Initiation under the Cards tab in the navigation window 2 Select a card holder by clicking the a button double click on a name or mark the name and click Select 3 Choose the expiration time of the card the default value is one day enter the number of days for which the card shall be valid or mark the El button next to the Expiration time field and mark a date in the calendar or enter a date manually The chosen date will appear at Expiration time the number of days will cha
23. cribed in section 3 2 and 3 3 This is to make sure that the ground is common for the elevator reader and all relay modules Elevator reader Four pole connector J9 be Re a Four pole connector J8 be Re a Picture 9 J9 Relay output see detailed description to the right J3 4 a RS485 3 A 2 T Regulated voltage in 1 the range 12 24V DC Note J9 and J8 are Timelox designations which are not visible on the elevator reader 8 Timelox AB 2005 Relay module The pictures of the elevator reader and the relay module are not of the same scale J9 3 is connected to J9 4 when the door is closed normal state see picture 10 No connection between J9 2 and J9 3 J9 3 is connected to J9 2 when the door is unlocked during the open time that is set up for the reader see 4 1 2 Setting up an elevator reader for details No connection between J9 3 and J9 4 See picture 10 J9 1 normally not used see picture 10 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b ce 1 Not used or other Electric door strike relay device Picture 10 1 Connect terminal 4 on the elevator reader to terminal 14 on the relay module 2 Connect terminal 3 on the elevator reader to terminal 13 on the relay module 3 Connect terminal 2 on the elevator reader
24. ct 865 253b 10 If you need to change Yes to No again for a common room enter the common room number at Change 1 8 and confirm with Enter If you need to clear all entered information for the output press the soft button Clear found below Clear shown in picture 34 11 When all set ups for the output have been done click the soft button Save found below Save shown in picture 34 12 If more outputs should be set up repeat steps 7 11 for each output 13 All outputs that have been set up will be listed see the example in picture 35 ELEVATOR OUTPUT NO 1l leaj SET UP DONE FOR 1 11 CLEAR TIME INIT Picture 35 14 When data for all outputs has been entered press the soft button Init found below Init shown in picture 35 15 Follow the instructions on the HCU screen The data will be transferred to the elevator controller 16 To modify the set up for an output the output must be chosen again as in step 7 Enter the modified data according to steps 8 11 Follow steps 14 15 to initiate the elevator controller The HCU saves the last initiation data for later use If more elevator controllers should be initiated with the same or similar data a new initiation is made with the stored data if desired after modification The HCU can only store one set of elevator initiation data If changes in initiation data have been made the new data is stored and the previous data is erased 6 1 1 Clearing all initiatio
25. details A common room on a guest card will give access to outputs which have the common room assigned Note The common rooms that are assigned to an output will only give access to magnetic cards Example The Guest card below is a magnetic card which will give access to relays which include room 104 in their room intervals and also to relays which have any of the common rooms garage lounge or restaurant assigned ioi x General Sa Guest EntranceCommon rooma User group Boom No 104 Group 7 ee No of nights fi O Sauna Check out time 3 11 2005 12 00PM No of cards 20 Issue to Po Meda _s Options f Magnetic Card TD Include track 2 data Smart Card Clear fields cose Picture 19 There are alternatives for assigning common access to restaurant floors etc see 4 3 2 Assigning common access Staff cards will give access to the elevator reader relays which are marked when issuing the card Example The Staff card in picture 20 on next page will give access to the first floor relay and the second floor relay and also to some ordinary doors 16 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b H Staff Card 5 x General PP Doors Card holder Hanson Susan E o ET af SS B Restaurant BIEIeEL e TE ia No of days
26. e 28 will give access to the relays for floor 1 relay and floor 3 relay and also to some other ordinary doors zi User Card O x Doors Floor 2 rela Floor 3 rela Entrances Big confere Floor 1 rela Users g Development Brown Peter pb Brown Tom tb Hanson Thomas th Swanson Sophie ss System manager System manager Sym Carlton tc SE MEEA 7 Tae gt See Larsen Mark ml Thomson James jt T on Production 4 Start time 5 29 200512 46PM Matrix is locked No of days Expiration time 5 29 2006 12 00 4M 1 IV Print receipt No access Card always Card and PIN always User list Save Hide Picture 28 Cancel cards will function as normally Blocking cards will block one or more user groups from certain relays see 5 3 Blocking a user group from an elevator reader relay for details Stand Open cards will set one or more relays in stand open mode see 5 3 2 Setting an elevator reader relay in stand open mode for details Note Emergency cards and Grand Master cards will activate all outputs connected to the elevator reader Visitor cards and Revoke Passage cards cannot be issued for elevator readers elevator reader relays 5 3 1 Blocking a user group from an elevator reader relay One or more user groups can be blocked from certain elevator reader relays for example corresponding to cer
27. e set in stand open mode The relays will be set in stand open mode at the first insertion of the stand open card and be reset on the second insertion Note The No of days regards the card s validity not the validity of the function 4 4 Service functions 4 4 1 Read out It is possible to read out the access list from an elevator reader it is however not possible to see which of the outputs that were opened The elevator reader can store 100 events 19 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b Read out with HCU Go to the applicable HCU menu 2 2 1 Complete LockLog 2 2 2 Error LockLog 2 2 3 Access LockLog or 2 2 4 Parameters press Enter to reach the Main menu press 2 Door unit menu then press 2 Read out menu and your choice for example 1 Complete LockLog Follow the instructions on the HCU screen Read out with card Issuing a read out card or read out card advanced in the DC One software l 2 Double click on Read out or if applicable Read out Advanced under the Cards tab in the navigation window Make the appropriate choices enter the appropriate fields etc in the card dialog For cards of type Read out Advanced it is possible to read only new events 1 e events that have not been marked as read in the elevator reader In this case check Only
28. econds the valid range is 1 30 seconds go to the Advanced tab see picture 17 below and enter the new open time Note The choices Allow On Off cards Keypad and Inncom are not applicable for elevator reader relays iix eeseeeeesesosssososesossesed Options F Allow On Off cards Keypad Open time 4 M Inncom Picture 17 11 Click New or Save or Update if an existing elevator reader was modified 4 2 Initiating elevator reader and elevator reader relays The elevator reader is initiated with an initiation card The initiation can be performed either before or after the system ID is set When an elevator reader is initiated parameters such as the calendar the date and time if that is chosen elevator reader number opening time opening mode and cancel list are transferred Also parameters for the elevator reader relays that have been set up for the elevator reader are transferred number opening time room interval and common room s for each relay Note If only time and date are to be set this can be done with the HCU This may be easier than using the initiation card for setting the time and date since the card must for this purpose be inserted at an exact time either directly after issuing it or ata certain time defined when issuing the card depending on whether Set time and today s date in lock or Set time and date in lock was chosen when issuing the card see picture 18 14
29. ersion 2 17 or higher of the HCU is required 1 If this has not been done before set up an appropriate COM port for the HCU in the 2300Win software go to File Select Devices Choose the appropriate COM port at HCU and click OK Connect the HCU to the COM port that you have set up in 2300Win 3 Enter the HCU menu 1 4 Set up from comp press Enter to reach the Main menu press 1 Set up menu and Enter press 4 Set up from comp and Enter 3 Go to File Setup HCU in the 2300Win software and click Continue The door list will now be transferred from 2300Win to the HCU 4 Enter the HCU menu 2 1 1 Initiate Direct press Enter to reach the Main menu press 2 Door unit menu and Enter press 1 Initiation menu and Enter press 1 Initiate direct and Enter 5 Choose 11 Elevator and press Enter You will get a screen as in picture 31 If a set up has been done before the outputs that have been set up are listed at Set up done for ELEVATOR 4 OUTPUT MO 1 128 SET UP DONE FOR CLEAR TIME Picture 31 6 The default opening time which shall be used for the elevator controller is 4 000 ms if this is to be changed press the soft button Time found below Time shown in picture 32 The opening time can be in the range 100 25 000 ms Enter the desired time and press Enter Note The opening time is common for all outputs of an elevator reader 7 Enter an output number between 1 and 128 see the example in picture 32
30. he door numbers on the card if the Member card is valid on the present day of the week Cancel cards Communication cards Daylight saving time cards and Standard time cards function as normal The functionality is however performed generally for all outputs not for individual outputs Lock time zones if applicable and blocking are general for all outputs a card that is blocked is locked out from all outputs and all lock time zones are general for all outputs As above cancellation is general for all outputs Note Emergency cards and Grand Master cards will activate all outputs There are a few cards in the MC EC system which will not function in the elevator reader Stand Open cards Personal Door Control cards Local cards or codes Revoke Passage cards 37 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 7 2 1 Examples of how to assign access Example 1 The door number examples are from MC but this example is applicable for EC as well An office building in three floors is used by three different companies One MC or EC system is used by the reception at the ground floor for all three companies e In this example the relays outputs are connected to the elevator control panel e When a card which opens relay 1 is inserted in the elevator reader the push button fo
31. ion against changes in the performance of the above described product 865 253b ELEVATOR DOOR NUMBER SECTION SECTION JECTION JECTION SECTION SECTION JECTION JECTION co Jom Of oo Po pe Picture 47 MC software Include the doors on floor 1 1002 1006 and also the door 1001 in section 1 the doors on floor 2 2002 2006 and door 2001 in section 2 and the doors on floor 3 3002 3006 and door 3001 in section 3 The persons in the management should have Section cards which give access to all three floors and all doors on each floor Note Make sure that the doors 1001 2001 and 3001 in the MC software are dedicated for the relays and not set up as ordinary doors j Section Card E loj x Card holder Barton Joanna Browse sections User group Management Mo of days fiso Expiration time 3710 2005 12 00 4M Card time zone I All day Start tine Stop time Check all Uncheck all owe Picture 48 As in example 1 the employees who work on floor 1 should from the elevator only have access to relay 1 that is elevator button 1 The employees at floor 2 should from the elevator only have access to relay 2 elevator button 2 and the employees at company 3 to relay 3 elevator button 3 When issuing a User card in the MC software to an employee at floor 1 assign access to elevator button but also to the employee s own room etc for example door 1003 When
32. ion in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b
33. is document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 2 3 Backup battery The elevator reader is delivered with a 9 V alkaline backup battery which should be exchanged every three years a battery holder and an adhesive pad The backup battery is used in case of external power failure for the reader only to maintain the time and parameters that have been set 1 Snap the battery into the battery holder 2 Connect the battery firmly to the battery connector 3 Fasten the adhesive pad at the back of the battery holder and fasten the battery holder where there is enough space for it 2 4 Relay module Timelox recommends that the relay module is purchased together with a rack for mounting with or without DIN rail The mounting rack is delivered with Weidmiiller gables AP 80 D see picture 3 below The rack is available in two lengths e 100 mm 3 15 16 inches mounting rack for 1 relay module Art No 866 438 e 400 mm 15 3 4 inches mounting rack for 2 4 relay modules Art No 866 439 Picture 3 Relay modules in mounting rack with AP 80 D gables The rack can be fastened with or without DIN rail For mounting on a standard 35 mm 1 7 16 inches DIN rail two Weidmiiller clips RF 180 are required see picture 4 below the clips are enclosed with the mounting rack Note The DIN rail is not supplied from Timelox Picture 4 R
34. ith EXAMPLES ccccccccccccccccccccccsecceseessnsaeeeseeeeeeceeseeesesessesssasaaaeeseeeeseeeeeeees O2 ASSIOHIN E COMMONGACCESS a AE EE A AAE ENE GD service FUNCTIONS saari E T S Did RATOU aAa a R E NA OD 2 POW CT OPEN i IEEE N NONNE COREENE ORAN UE NETA IORN EOE 7 Initiation daily use and service functions in MC EC esssssscccecessesoocoocecssosoccocceesoscoocecesssoosocecsssossocessssossseseee 7 1 Initiating elevator reader and elevator reader relayS ccccccccecesssssccceeceeseeseseneeeeeeccessessssseeeeeeeceseesaaeeeeseees 7 1 1 Clearing all initiation data from the HU viicccccccccccccccccccccccsccsessssssssesssnsceeeeeeeeeeeeeeesessesussussssasaaeeaeeeeees Fcc AMIS tie ecerscnetisalezarsairsess e Neate dle oa a A masse Cp EEN kad Examnes OF OW TODOS SUCH ACCESS easi Guay atti steointt Sui caste oie AT A 7 3 SEL VIC SLUICE OMS arc serena lesieatesssatstaasenidetv vad AN Tel IC ead ON au scien aa as Se ace a etait Eo Sea asain aa A tas VD Ze TOWO ONET EEE T AOAN EOE ETE Re ea SoA Diack Be RVR GAR aaa Appendix Quick reference of technical data csssccccsssssssssssscccssscsssssscccsssssssssssccccssssssssssssccssssssssssssssccsssees 1 Introduction The elevator reader needs a flat surface of 111 5 x 80 mm 4 7 16 x 3 3 16 inches see picture The elevator reader is constructed for built in mounting inside elevators The term elevator controller in this instruction refers to the elevator reader with one or more
35. llow the instructions on the HCU screen The data will be transferred to the elevator controller 20 To modify the set up for an output the output must be chosen again as in step 8 Enter the modified data according to steps 9 15 Follow steps 18 19 to initiate the elevator controller The HCU saves the last initiation data for later use If more elevator controllers should be initiated with the same or similar data a new initiation is made with the stored data if desired after modification The HCU can only store one set of elevator initiation data If changes in initiation data have been made the new data is stored and the previous data is erased 36 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 7 1 1 Clearing all initiation data from the HCU 4 Press the soft button Clear found below Clear shown in picture 42 5 You will get the question Do you want to clear all initiation data for elevators 6 Press the soft button Yes to confirm this 7 2 Daily use For every output it is possible to set up one door number that shall be granted access It is also possible to pick up to 16 sections not applicable for EC User cards will give access to outputs that correspond to any of the door numbers on the card Member cards will give access to outputs that correspond to any of t
36. n data from the HCU 1 Press the soft button Clear found below Clear shown in picture 35 2 You will get the question Do you want to clear all initiation data for elevators 3 Press the soft button Yes to confirm this 6 2 Daily use 6 2 1 Assigning individual access with examples Guest cards will give access to the output corresponding to the guest s room Note For guest access to floors with rooms such as restaurants see 6 2 2 Assigning common access 31 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b Staff cards will give access according to the card with room intervals etc Cancel cards and Power Down cards will function as normally One Time cards will not have the one time function in the elevator reader but function as ordinary access cards until they expire Note Emergency cards will activate all outputs There are a few cards in the 2300Win system which will not function in the elevator reader e Blocking cards for Suite cards e Clearance cards e Privacy cards e Stand Open cards 6 2 2 Assigning common access For floors that should be accessed by all guest cards for example a restaurant floor the concerned output must be set up to accept all cards in the guest room range see 6 1 Initiating elevator reader and elevator reader relays for detailed i
37. new events In order to read only new events check Mark events as read When all information has been entered click on Make Card or press F2 Insert a card in the encoder Making a read out I Insert the card in the elevator reader to make a read out there is a ticking sound while the information is being transferred to the card Wait for the signal before pulling the card or the operation will not be successful One read out card can be used in several elevator readers When the card is full a signal will alert the user Transferring the information to the Timelox PC for processing 1 2 Click on the icon Read Events from Card or if applicable Read Parameters from Card and insert the card in the encoder Click Read card to see the fetched events or parameters The events parameters can only be fetched from the card once then they are erased from the card they can however be read out from the door unit again 4 4 2 Power open It is not possible to perform a power open on an elevator controller 1f there is a failure in the elevator controller s external power supply 20 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 5 Initiation daily use and service functions in TC 5 1 Preparing for initiation in TC When the elevator controller has been mounted and connected
38. nformation It is also possible to set up 8 common rooms for each output see 6 1 Initiating elevator reader and elevator reader relays for detailed information Restaurants etc which should be accessed by all guests can be set up as general common rooms in the 2300Win software Go to Tools Options Guest cards and check the common room s which should automatically be included on all guest cards 6 3 Service functions 6 3 1 Read out It is possible to read out the access list from an elevator reader it is however not possible to see which of the outputs that have been opened The elevator reader can store 100 events 1 Go to 2 2 1 Read out 100 in the HCU press Enter to reach the Main menu press 2 Door unit menu and Enter press 2 Read out menu and Enter press 1 Read out 100 2 Follow the instructions on the HCU screen 6 3 2 Power open It is not possible to perform a power open on an elevator controller if there is a failure in the elevator controller s external power supply 32 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 7 Initiation daily use and service functions in MC EC 7 1 Initiating elevator reader and elevator reader relays When the elevator controller has been mounted and connected according to chapters 2 and 3 the elevator reader relays are set up as out
39. ng for initiation When the elevator controller has been mounted and connected according to chapters 2 and 3 the elevator readers and elevator reader relays are set up as doors in the DC One software After this 1s done an initiation card is issued in DC One for the elevator reader When the elevator reader is initiated the connected relays will automatically be initiated as well 4 1 1 Setting up an elevator reader relay For each elevator reader relay a room interval is set up for example the guest rooms on a certain floor It is also possible to assign up to all 28 available common rooms to a relay 1 Double click on Doors under the Lists tab in the navigation window 2 Click Add to add an elevator reader relay A dialog as in the example in picture 12 is shown ioj x General Advanced Type Elevator Reader Rely Name First foor Room interval hoo to 4139 Area Fistfloor Add Description FO Common rooms Garage W Lounge E AN C Sauna Picture 12 At Type choose Elevator Reader Relay Enter a Name for the elevator reader relay At Room interval enter the interval of rooms which are assigned for the relay At Area choose what door area the door shall belong to should there not be a suitable one make a new door area by clicking Add If desired enter a Description 8 At Common rooms all doors that have been set up to be of type Guest Common or PMS Common will be
40. nge accordingly 4 Mark the elevator reader that you want to initiate it will appear in the text field Initialize door 5 Choose one of the three date time options and fill in the fields accordingly 6 Click on Make Card or press F2 Insert a card in the encoder 5 2 2 Initiating the elevator reader Insert the card into the elevator reader at the exact time and date that were chosen when the initiation card was issued 1f time and date are to be set since that specific time will be set in the elevator reader There is a ticking sound while the information is being transferred to the elevator reader Wait for the signal before pulling the card or the operation will not be successful An initiation will be stored as at least two events in the event list to prevent tampering with the time in the elevator reader one event before the initiation and one event after and possibly some other events if the initiation causes the door unit status to change Note The initiation card can only be used once to avoid that two elevator readers are given the same identity 24 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 5 3 Daily use with example User cards will give access to the elevator reader relays which are marked when issuing the card Example The User card for Tim Carlton in pictur
41. oup s you want to block Note All groups except for the ones that are unchecked will be blocked also user groups that are added to the system after the blocking mode has been set in the door unit s It is not possible to block the user group to which the card holder belongs 5 At Doors check the relays from which you want to block the user group s in this example floor 2 relay Click on the plus sign in front of a door area to expand the area 6 Click on Make Card or press F2 Insert a card in the encoder Insert the card in the elevator reader The concerned relays will be blocked The relays will be set in blocking mode at the first insertion of the blocking card and be reset on the second insertion Note The No of days regards the card s validity not the validity of the function 26 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 5 3 2 Setting an elevator reader relay in stand open mode Each elevator reader relay can individually be set in stand open mode This is done by issuing a stand open card for the relay s that should be set in stand open mode iol Bener _ _ _ __Uw272 i Doos __ Card holder E oN Common areas User group a brary Ho of days fi n Lunch room A H 0 Conference rooms Expiration time
42. press the soft button 9 16 found below 9 16 in picture 40 Press Enter to confirm the door number 35 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b ELEVATOR DOOR MG d SECTION SECTION 10 SECTION 11 SECTION 12 SECTION 13 SECTION 14 SECTION 15 SECTION 16 CHANGE 9 163 CLEAR 1 8 Picture 4 13 The text Change 9 16 will appear below section 16 see picture 41 For each section that is to be included enter the section number at Change 9 16 and confirm with Enter The chosen sections will be marked with Yes 14 If you need to change Yes to No again for a section enter the section number at Change 9 16 and confirm with Enter If you need to clear all entered information for the output press the soft button Clear found below Clear shown in picture 41 15 When all set ups for the output have been done click the soft button Save found below Save shown in pictures 40 and 41 16 If more outputs should be set up repeat steps 8 15 for each output 17 All outputs that have been set up will be listed see the example in picture 42 ELEVATOR OUTPUT NO 1 128 _ SET UP DONE FOR 1 8 CLEAR PARAM INIT Picture 42 18 When data for all outputs has been entered press the soft button Init found below Init shown in picture 42 19 Fo
43. puts in the handheld communication unit HCU When the elevator reader is initiated with the HCU the connected relays will automatically be initiated as well Note Version 2 18 or higher of the HCU is required Note Before starting to initiate your elevator reader s have a look at 7 2 1 Examples of how to assign access for tips about how to set up the different outputs for different applications 1 If this has not been done before set up an appropriate COM port for the HCU in the MC EC software go to File Select Devices Choose the appropriate COM port at HCU and click OK Connect the HCU to the COM port that you have set up in MC EC 3 Enter the HCU menu 2 1 1 Read Init Data press Enter to reach the Main menu press 2 Door unit menu and Enter press 1 Initiation menu and Enter press 1 Read Init Data and Enter 4 Go to File Setup HCU in the MC EC software and click Transfer The door list will now be transferred from MC EC to the HCU 5 Enter the HCU menu 2 1 4 Initiate elevator press Enter to reach the Main menu press 2 Door unit menu and Enter press 1 Initiation menu and Enter press 4 Initiate elevator and Enter 6 You will get a screen as in picture 36 If a set up has been done before the outputs that have been set up are listed at Set up done for ELEVATOR OUTPUT NO 1 1281 SET UP DONE FOR CLEAR PARAM Picture 36 7 If pressing the soft button Param found below Param shown in pict
44. r floor 1 on the elevator control panel will lighten up e Access to door 1001 Elevator button 1 actually means access to floor 1 access to Elevator button 2 means access to floor 2 etc 3001 3002 3003 3004 3005 3006 Floor 3 company 3 2001 2002 2003 2004 2005 2006 Relay 3 3001 Relay 2 2001 Floor 2 company 2 Relay 1 1001 1001 1002 1003 1004 1005 1006 Floor 1 company 1 Picture 43 HCU When setting up relay output in the HCU according to 7 Initiating elevator reader and elevator reader relays the door number entered see picture 44 should be 1001 No sections are set up for the relay The door 1001 Elevator button 1 is not a physical door A card with access to Elevator button 1 will however open relay 1 which in turn gives the card holder access to floor 1 38 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b ELEVATOR DOOR NUMBER SECTION SECTION JECTION JECTION SECTION SECTION JECTION JECTION 1 2 J 4 z 6 7 G Picture 44 Relay 2 should be set up with door 2001 no sections and relay 3 with door 3001 no sections MC software The employees at company 1 located on floor 1 should from the elevator only have access to relay 1 that is door 1001 The employees at company 2 should from
45. relay modules There are different elevator controllers for different systems see article numbers below TimeLox DC One Art No for the elevator reader 684 040 021 TimeLox DC One with IR 5 option Art No for the elevator reader 684 040 022 TimeLox TC Art No for the elevator reader 684 040 031 TimeLox 2300Win Art No for the elevator reader 682 055 017 TimeLox MC EC Art No for the elevator reader 682 055 037 Relay module same for all the above systems 682 055 007 The information about mounting relay modules etc in this user manual is general for all four elevator controllers The information about connection of an elevator reader to a relay module initiation daily use and service differs between the different elevator controllers If nothing else is stated in the headings the information is general 2 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 2 Mounting 2 1 Cut out picture 9 3 8 75 3 80 3 3 16 i f p A 2 T S f 5 F yi S f a a if B PR ba f S nN ar A i f f 75 3 Measures in mm inches Picture 2 2 Mounting overview Note The ground wire must Ni be firmly connected m 6 amp 2 2 746 BOTE NS BF 2 5 8 Measures in mm inches Picture 2 Timelox AB 2005 The information in th
46. rmation in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 3 At Type choose Elevator Reader 4 Enter a Name for the elevator reader 5 At Area choose what door area the door shall belong to should there not be a suitable one make a new door area by clicking Add 6 If desired enter a Description 7 At Relay outputs mark a concerned output and click Select You will get a dialog where the elevator reader relays that have been set up will be shown see example in picture 15 i Select Elevator Reader Relay x Elevators ground floo Third floor relay Elevators ground floor Picture 15 8 Mark the appropriate relay and click OK 9 Repeat steps 7 8 for all concerned relays The result will be as in the example in picture 16 loxi General Advanced Type Elevator Reader x Name Elevator reader main elevator Area Elevators ground floor Add Description PO Relay outputs First floor relay Second floor relay Third floor relay n a n a n a n a n a 1 2 3 4 5 6 Fi 8 New Save Cancel Picture 16 13 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 10 If the Open time should be modified default is 4 s
47. shown see User manual TimeLox DC One Art No 865 100 for further information Mark the appropriate check box es Each elevator reader relay can give access to up to all common rooms Note The chosen common rooms will only give access to magnetic cards 11 lt oe a Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 9 If the Open time should be modified default is 4 seconds the valid range is 1 30 seconds go to the Advanced tab see picture 13 and enter the new open time Note The choices Allow On Off cards Keypad and Inncom on the Advanced tab are not applicable for elevator reader relays lolx Options T Allow On Off cards l Keypad Open time E I Inncom Picture 13 10 Click New or Save or Update if an existing elevator reader relay was modified 4 1 2 Setting up an elevator reader 1 Double click on Doors under the Lists tab in the navigation window 2 Click Add to add an elevator reader A dialog as in the example in picture 14 is shown 5 x General Advanced Type Elevator Reader F Name Elevator reader main elevator Area Elevators ground floor x Add Description Ce Relay outputs 1 2 3 4 5 n a 6 7 8 Select Remove yon See coe Picture 14 12 Timelox AB 2005 The info
48. tain floors This is done by issuing a blocking card for the relays that are to be blocked Note The TC system can in total have 200 user groups 25 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 10 x General Doors Card holder Linton Saah ia H Common areas _ Conference rooms User group Logistics D O Development No of days Elevators Expiration time 3711 2005 12 00 AM C Floor 1 relay W Floor 2 relay Floor 3 relay Block User groups H 0 Entrances V Development i Finance C Finance C Logistics Logistics H 0 Marketing _ Marketing C Production Production C Visitors Check all Uncheck all Check all Uncheck all cine Picture 29 1 Double click on Blocking under the Cards tab in the navigation window 2 Select a card holder by clicking the button double click on a name or mark the name and click Select 3 Choose the expiration time of the card enter the number of days for which the card shall be valid or mark the E button next to the Expiration time field and mark a date in the calendar or enter a date manually The chosen date will appear at Expiration time the number of days will change accordingly 4 At Block User groups check the user gr
49. the elevator only have access to relay 2 door 2001 and the employees at company 3 to relay 3 door 3001 When issuing a card in the MC software to an employee of company 1 see picture 45 assign access to door 1001 but also to the employee s own room etc for example door 1003 When the employee inserts his card in the elevator reader the push button for floor 1 on the elevator control panel will lighten up When the employee should access his own room etc he inserts his card in this particular door Note Make sure that the doors 1001 2001 and 3001 in the MC software are dedicated for the relays and not set up as ordinary doors ioj Uist 5 fechon oiea fe Heng Anderson Tom tal Float Pigwa Arras ab C Float 2 Mabden Steven em C Fhag Seih Sopher z Seelam manager Seen mane Syn Compan 2 Eaton Tray i Hal Thomas th Shewen ali IEG permth_ cee ai J Sophat ofhoe 1000 Weila Martin rey Amea ahes 10H Coney 2 Tom s oiio 1005 Ardan Lespls fla Liga nom U Farhan iaraa 5 oo Pal done Jar 1008 Hiire Theri Ihe Johnin Mity rri Biwi Caid ina pora fe Ady Moy of lager fies Giai bere Eyan irre TIL TA A Grap tere F Pin sep gave Hakecad Hide 39 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b
50. umber of days for which the card shall be valid or mark the eal button next to the Expiration time field and mark a date in the calendar or enter a date manually The chosen date will appear at Expiration time the number of days will change accordingly 4 At Block User groups check the user group s you want to block Note All groups except for the ones that are unchecked will be blocked also user groups that are added to the system after the blocking mode has been set in the door unit s It is not possible to block the user group to which the card holder belongs 5 At Doors check the relays from which you want to block the user group s in this example first floor relay and third floor relay Click on the plus sign in front of a door area to expand the area 6 Click on Make Card or press F2 Insert a card in the encoder Insert the card in the elevator reader The concerned relays will be blocked The relays will be set in blocking mode at the first insertion of the blocking card and be reset on the second insertion Note The No of days regards the card s validity not the validity of the function 4 3 4 Setting an elevator reader relay in stand open mode Each elevator reader relay can individually be set in stand open mode This is done by issuing a stand open card for the relay s that should be set in stand open mode 18 Timelox AB 2005 The information in this document is subject to change without notice
51. ure 36 some parameters can be modified 33 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b ELEVATOR WISE LTZ OFEN MODE OFEN TIME Picture 37 Whether lock time zones should be used or not default is Yes open mode default is 0 that is door unit unlocks after card has been inserted and locks after lt open time gt seconds see next page for a description of all possible open modes open time the default open time which shall be used for the elevator controller is 4 000 ms the opening time can however range from 100 to 25 000 ms Press Enter to jump to the next parameter Note The use of lock time zones the open mode and the open time are common for all outputs of an elevator reader Open modes 1 door unit unlocks and gives a signal after card has been ejected and locks after lt open time gt seconds 2 door unit gives a signal after card has been inserted unlocks after card has been ejected and locks after lt open time gt seconds 3 door unit unlocks after card has been inserted and locks after lt open time gt seconds when card has been ejected 8 Enter an output number between and 128 see the example in picture 38 ELEVATOR OUTPUT NO 1 128 1 SET UP DONE FOR CLEAR PARAM Picture 38 34 Timelo
52. vancasasacavevecsssdeaenasdeasns T A 23 eld sune an uNa On CGY Cases Se Suse EA Caticulta es sence A sd eae cae aed oo A Sik vw OHA a en ee EER 24 DZ 2 ANOS MC CLE V ALOT TCAD ET skein hasnt esl os AOA ed 24 5 5 Datly Usex Witmexaimple jas mn ka seb suasebunabbiceshavsauenneecaaullasneen sane 25 5 3 1 Blocking a user group from an elevator reader relay cccccccccccccceseveesvescceceeeeeeceeceeesesssesessassaeeaeeessseseees Zo 5 3 2 Setting an elevator reader relay in stand open mode oicieccccssccccccccccccccceceeceeeeseesessesuneasaeeaeeseeeeeseeseseseeeees 27 DA SELVICS LUNE OMG eysisestai oes nesticcautsacwncuaecawadtasi A deeana calluses a alldrameketauiates 28 JAFRA OUT silt alihe ete a a Sec aaticad Dacha ela es Raids gtd eased Cad a sect ean eaae 28 6 Initiation daily use and service functions in 2300Win ssssscooocecsssoscoccccccsssosooecesesosooooecesesoooosoecesseososeeecessos 29 6 1 Initiating elevator reader and elevator reader relays ccesccccccessssesnccceceeeeesesneaeececcessessseececesseeaaeeeeeeesseas 29 OL Clearing all mitationdata fromthe TLC ice eke os 38 ead xs E E aaa oa eee 51 Timelox AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b DM US eth pects tae grist seme A nee elon cate labs A S E he A E ne a I A ON ba bad Macs die TEE 6 2 1 Assigning individual access W
53. x AB 2005 The information in this document is subject to change without notice Timelox AB makes a reservation against changes in the performance of the above described product 865 253b 9 Press Enter You will get the screen shown in picture 39 At Door No enter the number of the door that is to be included for this output Press Enter ELEVATOR DOOR MO O SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION amp SECTION 7 SECTION CLEAR Picture 39 Note Make sure to use the same door numbers for the same doors when initiating the elevator reader and when setting up doors in the EC MC software see 7 2 1 Examples of how to assign access for more information 10 The text Change 1 8 will appear below section 8 For each section that is to be included not applicable for EC enter the section number at Change 1 8 and confirm with Enter The chosen sections will be marked with Yes see the example in picture 40 ELEVATOR DOOR MO gt SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 SECTION 7 SECTION 8 CHANGE 1 87 CLEAR 9 16 Picture 40 11 If you need to change Yes to No again for a section enter the section number at Change 1 8 and confirm with Enter If you need to clear all entered information for the output press the soft button Clear found below Clear shown in picture 40 12 If any of the sections 9 16 should be included not applicable for EC
54. xD 67 x 92 x Max 60 mm 2 5 8 x 3 5 8 x 2 3 8 inches Dimensions relay module with DIN rail WxHxD 100 x 67 8 0 2 x 75 mm 3 15 16 x 2 3 4 x 3 inches Electrical specification e External power supply of regulated voltage in the range 12 24 V DC e Maximum current consumption for the elevator reader 100 mA continuously e Maximum current consumption for each relay module 100 mA continuously e 8 outputs per relay module e Maximum 128 outputs e RS 485 standard for the serial interface connecting the different modules e If the distance from elevator reader to relay module is gt 20 metres shielding is required The shield should be connected to protective ground at one end Backup battery e 9 V alkaline included at delivery e Exchange every three years Relay module e Timelox recommends that the relay module is purchased together with a mounting rack for fastening with or without DIN rail e The rack is delivered with Weidmiiller gables AP 80 D 2 pcs and enclosed are also Weidmiiller clips RF 180 2 pcs The clips are used for fastening on the DIN rail HCU e DC One TC Any HCU version can be used e 2300Win Version 2 17 or higher is required e MC EC Version 2 18 or higher is required Timelox software e DC One Version 1 6 or higher is required e TC Version 1 4 or higher is required e 2300Win Any software version can be used e MC EC Any software version can be used 43 Timelox AB 2005 The informat