intralux 5100 User`s Manual

image

Contents

1. 0 intralux 5100 CH 230 240V 50Hz 10441 intralux 5100 JAP 100V 60Hz 200W 2A slow blow 250V 2pcs P N 90045 112 2A slow blow 250V 2pcs P N 2421 01 EKE 21V 150W Halogen reflector lamp P N 13695 110 100h 105 140h 100 200h 95 310h 90 520h 85 900h 80 1700h 75 3 600h average calculated values for continuous operation 400 700nm Approx 3 433K at 110 intensity setting Approx 12 3M Lux at light guide input DIN 58141 10 215x120x200mm 4 6 kg net 5 C 40 C 20 80 Site conditions for transport and storage Temperature Range Relative humidity General information Over voltage category Degree of pollution Protection class Approvals UL61010 1 CAN CSA61010 1 CE 20 C 60 C 20 80 Product Safety IEC EN 61010 1 2001 EMC Emission IEC CISPR 11 Class B EMC Immunity IEC 61000 4 2 to 6 and 11 Page 12 of 12
2. 6 by squeezing the double sided plastic part and replace it with a new one of the identical type and replace the halogen lamp 14 according to 4 1 d e Close the top cover 7 Push the sliding lock 6 to the rear then forward to lock the top cover 7 f Connect the power cable 1 to the appliance plug 20 and to the voltage outlet g Set the power switch 10 on then the 0 is not visible 4 4 Transport In order for instruments to be transported under normal freight conditions without being damaged they should be transported and or sent in their original packing Jolts during transport are to be avoided Page 10 of 12 4 5 Cleaning The light source must only be wiped with a slightly moistened cloth In no case must liquid be allowed to enter the instrument Afterwards rub dry with a dry cloth If easily flammable solutions are used the instrument must first be disconnected from the electrical power supply and allowed to cool down as it could otherwise catch fire Page 11 of 12 5 TECHNICAL DATA Designation Part No Power consumption Fuses for 230V unit Fuses for 121V unit Lamp type Lamp lifetime electrical Intensity setting Spectrum Color temperature Illumination Intensity HxWxD Weight Site conditions for operation Temperature Range Relative humidity Cold Light Source intralux 5100 10438 intralux 5100 USA 120V 60Hz 10437 intralux 5100 EURO 230 240V 50Hz 1044
3. can be ordered with our sales agents or directly from Volpi USA Color Filters Ringlights Gooseneck Light Guides Incident Light Guides Illumination Light Guides Page 7 of 12 3 4 Checklist In Case Of Faults Condition Cause Remedy Remarks no light instrument fuses replace fuses See defective connect plug paragraph 4 2 plug not connected to switch on light See electrical supply source paragraph 4 1 light source not replace lamp switched on return instrument lamp defective to supplier transformer defective Page 8 of 12 4 MAINTENANCE AND CLEANING 4 1 Halogen Lamp Replacement P N 13695 CAUTION The Halogen lamp should be cooled down due to risk of burning Afterwards remove lamp from lamp holder with a cloth a Set the power switch 10 off then the 0 is visible and disconnect the power cable 1 from the appliance plug socket 20 and from the voltage outlet b Push the sliding lock 6 back open the top cover 7 c Using a cloth remove the defective halogen lamp 14 with the lamp socket 15 from the lamp holder 13 and disconnect it from the lamp socket 15 d Replace the halogen lamp 14 with a new one of the identical type Connect it to the lamp socket 15 and place it in the lamp holder 13 Push the new lamp down into the lamp holder 13 to a positive stop Do not touch the quartz or the inside of the reflector e Close the top cover 7 Push the sliding
4. intralux 5100 User s Manual 72 6196 72 6198 Swiss Plug HARVARD APPARATUS Harvard Apparatus 84 October Hill Road Holliston MA 01746 USA Phone 508 893 8999 Fax 508 429 5732 bioscience harvardapparatus com www harvardapparatus com Page 1 of 12 TABLE OF CONTENTS 1 INSTRUMENT OVERVIEW 2 DESCRIPTION OF INSTRUMENT 2 1 Application 2 2 Features of the instrument 2 3 Scope of supply 2 4 Symbols used 3 START UP AND OPERATION 3 1 Safety measures 3 2 Start up 3 3 Operation 3 4 Checklist in case of faults 4 MAINTENANCE AND CLEANING 4 1 Replacement of halogen lamp 4 2 Fuse replacement 4 3 Lamp socket replacement 4 4 Transport 4 5 Cleaning 5 TECHNICAL DATA Page 2 of 12 1 INSTRUMENT OVERVIEW gt CETE T30 M0 V 750 Hr VOLPI AG o is soumes tepl WARNING Beem s TOA ALi wae oF mawari tere ues TOR 13 14 Page 3 of 12 LEGEND WOON AU BRWN FE Description Power cable Filter holder without filter color filters on request Filter holder receptacle Light guide receptacle Carrying handle Sliding lock Top cover Brightness control knob crescent shaped diaphragm Intensity control knob electrical lamp intensity setting 8 steps Power switch Type plate Warning plate Fuse holder Fuses 2 pieces for e 230V mains 2A slow blow 250V p n 90045 112 e 121V and 100V mains 2A slow blow 250V p n 2421 01 Appliance plug socket Lamp holder Halogen reflector lam
5. lock 6 to the rear then forward to lock the top cover 7 f Connect the power cable 1 to the appliance plug socket 20 and to the voltage outlet g Set the power switch 10 on then the 0 is not visible 4 2 Fuse Replacement 121V P N 2421 01 230V P N 90045 112 a Set the power switch 10 off then the 0 is not visible Disconnect the power cable 1 from the appliance plug socket 20 and the voltage outlet b Pull the fuse holder 18 containing two operating fuses 19 from the spring loaded holder in the appliance plug socket 20 Page 9 of 12 c Remove defective operating fuse s and place fuse in the fuse holder 18 according to the value on type plate Buy new fuse s immediately d Connect the power cable 1 to the appliance plug 20 and to the voltage outlet e Set the power switch 10 on then the 0 is not visible 4 3 Lamp Socket Replacement P N 10435 110 If the lamp socket 15 shows signs of burning and wear between the lamp pin contacts it must be replaced We recommend a change after use of 5 lamps The lamp should be cooled down before it can be removed a Set the power switch 10 off then the 0 is visible and disconnect the power cable from the appliance plug socket 20 and from the voltage outlet b Push the sliding lock 6 back open the top cover 7 c Remove the halogen lamp 14 according to 4 1 c d Pull out the defective lamp socket 15 from the lamp socket connector 1
6. low certain specified instructions where safety is involved In case of non observance persons could be put at risk could cause dysfunction or device damage A Heat Lamps and heat sinks may emit extreme amounts of heat during and after operation Approach and handle these and other potentially hot components with caution Page 6 of 12 3 1 3 2 3 3 START UP AND OPERATION Safety Measures CAUTION In order to prevent overheating of the instrument always ensure that the ventilation slits are never obstructed by foreign objects Start Up 1 Before starting up check that the voltage given on the type plate 11 is the same as the local power voltage 2 Connect the power cable 1 to the appliance plug 20 and to the voltage outlet 3 Plug the light guide into the light guide receptacle 4 4 Switch the power switch 10 on then the 0 is not visible Operation 1 Set the power switch 10 on then the 0 is not visible 2 Adjust intensity by the intensity control knob 9 This electric 8 steps intensity regulation changes the color temperature of the lamp but increases the lamp life 3 When the intensity setting has been selected the light supply can be adjusted progressively by using the mechanical brightness control 8 4 Ifthe unit is not used according to the User s Manual of the manufacturer the provided protection can be impaired 5 Following accessories for the Intralux
7. p p n 13695 Lamp socket p n 10435 110 Lamp socket connector Fan DC Page 4 of 12 2 DESCRIPTION OF INSTRUMENT 2 1 2 2 2 3 Application The intralux 5100 cold light source has been specially developed for the illumination of Stereo Microscopes and fulfils the most demanding requirements concerning safety and performance Features Of The Instrument To satisfy increasing demands for lighting with high color fidelity the intralux 5100 has been equipped with a specially developed Crescent Shaped Diaphragm giving manually operated brightness control which does not alter the color temperature of the lighting In addition to the mechanical light regulation there is a built in electrical 8 steps switch which allows reducing the secondary lamp voltage from 110 to 75 increasing the average lamp life but decreasing the color temperature 110 intensity 100h 105 140h 100 200h 95 310h 90 520h 85 900h 80 1 700h 75 3 600h calculated values in continuous operation The electrical reduction of the light intensity increases the lamp lifetime considerably Therefore we recommend working on 80 or 85 intensity setting Scope Of Supply intralux 5100 Filter holder blank Power cable EURO Schuko CHF USA GB version not available Page 5 of 12 2 4 Symbols Used A Caution Refer to accompanying documents used to direct the user to the instruction manual where it is necessary to fol

Download Pdf Manuals

image

Related Search

Related Contents

Neptune 1_2, Neptune 2 Special 107145403_D.indb  Ives 54 User's Manual  BAT-200 Battery Tester Product Manual  Motores de 75/90/115 HP EFI de 4 Tempos    Fall 2013 PivotPoint  1087557-2-E  Personal Power Station PPS16  AIRCARE 826000 Use and Care Manual  Manuale di Debian Edu / Skolelinux Wheezy 7.1+edu0  