Microwave Intrusion Sensor “FORTEZA
Contents
1. ASTO TA oo ace enn E EE AE TE EE ES 13 Transporta onssa r eee ea aA EA EAE ESES Certificate resnemu ne ro en EE EE E Tane TAr VSI Sie Kitaar aesa aE a a a tote E E e 2 Acceptance certificate sseeseseeseeeeessreessreesssressreesssresseressseessees gt 3 Manufacturer s guarantees 129 26 26 32 on 33 33 34 35 36 36 36 1 INTRODUCTION 1 1 The present user manual contains the information about the principle of operation structure and operating rules of the Microwave Intrusion Sensor Forteza Lamp 1 2 The following abbreviations are used in the present document Tx transmitting unit Rx receiving unit DZ detection zone CSCP centralized surveillance control panel 2 PURPOSE 2 1 The sensor Forteza Lamp is a bistatic intrusion device Their transmitting and receiving units are made in the form of park lamps The purpose of the sensor is to form concealed long protective boundaries and at the same time it is intended for the decorative lighting 2 2 The sensor is intended for continuous round the clock operation under the conditions of open space It ke
2. Notes The decorative lamp is a lighting unit and doesn t differ from the lamps in which Rx and Tx are installed The installation and connection are realized similarly The application is for the decorative lamps of long perimeter sites They are delivered on the customer order 5 1 4 The boundary s configuration can have any form Tx and Rx antennas can rotate at the angle 180 horizontally and at the angle 25 vertically 5 1 5 When an intruder enters a DZ electromagnetic field is changed and as a result the parameters of a signal received by Rx are changed either In the standby state Rx constantly processes a received signal compares its value with set thresholds and on the basis of the results of processing it makes a decision on the generation of alarms The information is processed by the microcontroller 5 1 6 Change of electromagnetic field in the DZ can be caused not only by an intruder but by other factors too vibration of grass branches bushes small animals rain reflection from walls and barriers etc These factors are interference because they make difficult reliable friendly signal extraction caused by an intruder against their background More than that interferences of considerable rate can cause the sensor response these responses are called false alarms That s why it is necessary to follow the requirements at the sector s preparation and their installation 1 8 1 8 5 1 7 When an intruder enters
3. action lt 3sec during the indicators 1 and 2 glowing b Obtain the maximum level of the signal c Leave Alignment mode and enter Setup mode action 5 6 sec 5 2 4 3 Thresholds installation In this mode the values of thresholds are set using controlled crossings of a detection zone s sector Later on these values are used by the controller when an alarm signal is generated 12 This stage of the setup is very important because if it is carried out correctly it provides the high immunity of the sensor to the influence of noise during operation and declared detection probability The thresholds installation is carried out for each sector Two people take part in training One of them an intruder crosses a detection zone The crossing of the detection zone comprises For the sensors installed on the upper part of the fence the stile through the fence you can use the stairs For the sensors installed on the wall approach to the wall is right or intrusion through the window For the sensors installed horizontally an intruder crosses a detection zone to full height and bent position The crossing of the detection zone should be performed in the centre of the sector and at the distance of 1 4 from the sector s length from Tx and Rx Choosing the problem places of a sector in cavities on heights and so on An intruder is a person his weight is 50 75 kg height is 165 180 c
4. Decorative lamp Ne 23 2 ACCEPTANCE CERTIFICATE 2 1 The kit of the sensors given in Table 1 meets performance specifications of the Document Part Number 4372 43071246 058 and it is considered as operable Date of issue __ _20 Quality department 3 MANUFACTURER S GUARANTEES 3 1 The manufacturer guarantees the conformity of the sensor specifications to requirements of the Document Part Number 4372 43071246 058 if a user meets the service conditions and operating rules 3 2 Warranty period is 18 months since the date of sale by the manufacturer 3 3 Guarantees do not covert the sensors with mechanical failures and also those which are out of order because of natural disasters lightning fire and flood mishandling 3 4 Mean lifetime is 8 years Manufacturer JSC OKHRANNAYA TECHNIKA P O box 45 Tel Fax 7 8412 65 53 16 E mail info forteza eu com For warranty and post warranty service you can contact Technical Service Center of JSC OKHRANNAYA TECHNIKA P O box 45 442960 Zarechny Penza region Russia Tel Fax 7 8412 65 53 16 multi channel info forteza eu com 24
5. d The presence of decorative lanterns video cameras immovable small objects is possible It is necessary to reduce the length of the sector at 10 from the maximum one for every object 8 1 3 Installation on the ground ground connection 8 1 3 1 Follow the requirements a The direct visibility should be provided between Tx and Rx b No bushes branches of trees high grass gt 0 3 m snow gt 0 6 m c It is not recommended to install the DZ axis nearer than 1 1 5 m from the lengthy objects fence walls etc because it can reduce the received signal level and the detection d The big object movement car gates crowns of big trees etc nearer than 3 5 m from the DZ axis is not recommended e The presence of decorative lanterns trunks of the trees without branches and immovable small objects is possible It is necessary to reduce the length of the sector at 10 from the maximum one for every object 8 2 Sensor Mounting 8 2 1 Mark the perimeter for the places where the units are mounted Lay the main cables and signal lines Follow the requirements 5 1 2 5 1 3 and 8 1 8 2 2 Install the sensors supply units and commutation from the delivery kit and the junction boxes according to the project documentation and 1 6 of the user manual 8 3 Sensor Connection 8 3 1 Connect the necessary supply lines and alarm lines in the junction boxes JB according to table 8 1 and fig 8 1 Before that pass the cables of
6. e channel II 6 supply board and light control H 7 attachment fitting 8 clamp bolt 9 cable connector 10 thread bushing M10 of the lamp case 10 Fig 6 1 15 6 2 The bearing structure of 2 Rx is bean 1 turned on the bushing of the lamp case 10 the case is not shown and is fastened with the bolt 8 The base board of processing 2 and the supply board 6 with the cable connector 9 are fixed on the bean The cable 3 is passed through the bean the case s bushing and the lamp case and then through the connector 9 it is connected to the base board of processing The receiving antennas 4 and 5 of the channels of processing T and II are installed on the bean and is connected to the base board of processing The attachment fittings provide the possibility to turn the antennas at the angle 180 horizontally and at the angle 25 vertically 6 3 The difference of 1Rx construction is the absence of the antennas II and the channel elements II on the base board of processing 6 4 The difference of 1Tx and 2 Tx construction is the presence of the base board of the modulator instead of the base board of processing and the transmitting antennas instead of the receiving ones 6 5 The mounting and the installation of the sensors a Unpack the component parts b Install the lamp on the place with the self cutting screws c Connect the cable of the unit 3 to the junction box 7 SAFETY MEASURE
7. is chosen from the price list MB WN 6 Tx cable 1 item for the Tx unit 7 Rx NC cable 1 item for the Rx unit 8 User manual 1 item for every kit 9 Package Note It is possible to deliver the decorative lamp without sensor with the lighting function only 5 SENSOR ARRANGEMENT amp OPERATION 5 1 Sensor Principle of Operation 5 1 1 The sensor is a bistatic microwave detecting unit The principle of operation is to generate a volumetric detection zone in the space between a transmitting and a receiving unit 5 1 2 There is a possibility to install two transmitting antennas in the Tx unit two receiving ones in the Rx unit One Tx or Rx unit can join the neighboring perimeter sites It provides the expenses saving at the long boundaries generation To exclude the overlapping of the perimeter sites the Tx units have two variable frequency letters marked A and B on the base boards The letter changing is performed by the jumper on the Tx base board The Rx units are universal and can synchronize with the Tx unit of any letter There are two independent channels of processing with their individual point relay control and indication parts marked T and TT on the Rx base board 5 1 3 The principle of the perimeter s sites generation is given in fig 5 1 Extreme transmitting unit Middle receiving unit Middle transmitting unit letter A i Extreme receiving unit Fig 5 1
8. of snow is more than 0 6 m in the DZ the snow should be taken away 20 11 TROUBLESHOOTING GUIDE 11 1 List of possible troubles is given in table 10 1 Table 10 1 1 The 1 Communication signal or Check the cable integrity and its alarms are current supply line is right connection Restore the generated broken contacts oxidation communication line constantly gahe 2 The sensor alignment is Align Tx and Rx antennas disturbed 3 Power supply is less than Provide the accordance of the the norm or absent power supply according to 1 3 4 control panel 4 The perimeter sector Check the perimeter sector doesn t correspond to the according to the requirements requirements 1 8 1 and remove the failure 5 Tx or Rx fails Replace Tx or Rx 2 False 1 There are moving Inspect the sector and remove alarms of the branches in a detection zone interference factors sensor and they cause alarms branches of trees bushes high grass etc 2 The input signal is Adjust according to 1 5 2 4 2 reduced on Rx because of the environment change 3 Animals circulate in the sector 4 The Rx thresholds are too Adjust the sensor according to low 1 5 2 4 3 21 Trouble Possible Cause 3 The 1 Rx thresholds are too Adjust the sensor again according sensor does high to 1 5 2 4 3 not generate alarms when an intruder crosses the sector 4 The LED 1 The lighting control line Check the l
9. sensor units are out of order the remote control RC signal is generated An alarm is generated by opening the contacts of optoelectronic individual point relay NC contacts for 3 sec minimum 3 3 The dimensions of the individual point relay switched current is 0 1 A max switched voltage is 50 V max resistance in the closed mode is 110 Ohm max 3 4 The sensor power supply is realized from dc source of the voltage 24 8V 5 3 5 The maximum power used by every sensor s unit Tx or Rx when the light is switched ON is 12 Watt 3 6 The maximum power used by every sensor s unit Tx or Rx when the light is switched OFF is 0 6 Watt 3 7 Every unit has the function of the lighting control The control is realized by closing breaking of the cable CONTROL on the power supply The parallel connection permits to control some units to switch ON OFF the light synchronously The cable resistance of the control line should not exceed 2kOhm 3 8 The lighting at the distance of 1m from the unit is 47 Ix corresponds to the incandescent lamp of 75 Watt 3 9 The sensor is immune to the influence of EMI voltage impulses in the supply circuits breaks of mains power supply electrostatic discharges electromagnetic fields 3 10 The sensor doesn t generate an alarm in the cases small animals e g cats birds like pigeons move in the detection zone mobile phones operation in the radius 22 m from the Rx u
10. 5 2 4 9 2 2 Install the lamp bowls on the cases of the sensors after the setup After the sensor adjustment it is recommended to carry out its trial operation for 2 3 days to reveal and eliminate possible mistakes of mounting and adjustment 19 Note To exclude the visible glowing of the indicator lamp in the separated lamp cases it is recommended to glue the indicators with the lightproof splice 10 MAINTENANCE CHECK 10 1 Performance check of the sensors 10 1 1 During the sensor exploitation it is recommended to check remote control RC 1 3 times in a day 10 2 Servicing 10 2 1 The sensor should be served by the technicians after special training and instruction 10 2 2 During the service of the sensor it is necessary to conduct the check and preventive works 10 2 2 1 Every month carry out the external examination of the sensor units and the state of the sector where Tx and Rx are installed It is necessary to check the absence of dust dirt snow and ice on the lamp bowls the absence of outside objects in the sector where Tx and Rx are installed 10 2 2 2 Every quarter carry out all the works specified as works carried out every month check the state of the cables and cable connections 10 2 3 During the seasonal works the height of grass is controlled for the wall and ground mounting If the height of the grass is over 0 3m the grass should be cut or removed by another method If the height
11. S 7 1 The staff must have the leave for work with electrical facilities up to 1000V voltage to install set and maintain the sensor 7 2 It is prohibited to mount and to maintain the sensor during lightning storm 8 MOUNTING PROCEDURE 8 1 Requirements for the sector preparation and the application conditions 8 1 1 Installation on the upper part of the fence 8 1 1 1 It is recommended to install the sensors on the upper part of the fence from the inside Follow the requirements a The direct visibility should be provided between Tx and Rx b Height of the obstacles relative to the detection zone should not exceed 0 3m vertically and 0 1 m horizontally c No wind and other vibration of the obstacle d No bushes branches of trees sheet of water water flow in the detection zone e The presence of decorative lanterns video cameras immovable small objects is possible It is necessary to reduce the length of the sector at 10 from the maximum one see table 3 1 for every object 16 f If it is necessary to reduce the DZ dimensions to exclude the presence of people animals branches and bushes choose the corresponding minimum sector s length see 1 3 1 8 1 2 Installation on the wall 8 1 2 1 Follow the requirements a The direct visibility should be provided between Tx and Rx b No bushes branches of trees sheet of water water flow in the detection zone c No wind and other vibration of the obstacle
12. a RTEZAI Microwave Intrusion Sensor FORTEZA LAMP User manual 2010 TABLE OF CONTENT User manual I Introduction areire areke aeaiee aee eee ee mes De PUR DOSC 00 son n E A EA S Da Specifica lons e e e E E R E EEE RRE 4 Sensor Components ssssseseseseessessseseesseressreessresssseesseesseseesseesssees 5 Sensor Arrangement amp Operation eessesesssessseseesseessssresssresssees 5 1 Sensor Principle of Operation ssesssesessseesseseesssesssereesseressees 5 2 Operation Modes seessssesessseessesessseresseressseesseressserssereesseesseres DD Sensor Op ration eie ee EEEa E r EE 6 Sensor Str ct re Aara ee aaea ie teaa a ia ria eE aaah TaSatety IVES ASUTCS s1 3 cues r a n a r a sawn 8 Mounting Procedure io siecn pascneneunceteauscesdoussiauncsseninecendnacuouneuaadesis 8 1 Requirements for the sector s preparation and the application conditons 5 cet orea Eaa AE aa ata E or eee ee AAE EEEa 2 Sensor MOUNN S assnret ae ni SP Sensor C NNecCHUON isseire iee ae e e ean e daze E REENE aie Sensor Setting up Procedures and Adjustment ceeeeees 1 Setting up Procedures sseeeseseesseeesssressesessseesseressseessereessress DE ASCTISOTS SCUD a ae E e a AT E a a enews LOW Miami te mance CHECK vmint a a a 10 1 Performance check of the sensors ecccceesseceeeteeeeeneeeees Os SSP VAC IIS Scar seca calaes wees asec cee n A A RES 11 Troubleshooting guide
13. a detection zone Rx generates an alarm by single opening of the individual point relay contacts If the cause of alarm generation is not remedied the sensor generates multiple alarms 5 2 Operating Modes 5 2 1 General Information 5 2 1 1 There are three operating modes of the sensor standby mode alarm mode setup mode 5 2 1 2 Indication of operating modes is carried out by CSCP according to the state of the individual point relay contacts different variants and combinations of three light indicators 1 2 and 3 on the Rx base board 5 2 1 3 Light indicators are available only for the monitoring when a sensor case is removed that s why they can be used during installation and setup The Rx light indicators position is given in fig 5 2 Note The signal channels II are absent in the extreme receiving unit 1 Rx 1 supply board and lighting control 2 thresholds controller of the 1 channel 3 indicator lamps of the 1 channel 4 button PEXKMUM MODE of the 1 channel 5 thresholds controller of the 2 channel 6 indicator lamps of the 2 channel 7 button PEXKMM MODE of the 2 channel 8 connector for the cable connection Fig 5 2 Press on the button PEXKMUM MODE and operate with the sensor modes There are two types of pressing long press the button PEXKMM MODE more th
14. an 3 sec 5 6 sec fast press the button PEXKUM MODE less than 3 sec lt 3 sec 5 2 2 Standby mode 5 2 2 1 Standby operating mode of the sensor is indicated by closed state of the individual point relay contacts periodically short time switching ON of 2 indicator if the automatic thresholding was performed periodically short time switching ON of 3 indicator if the automatic thresholding was performed 5 2 3 Alarm mode is indicated by individual point relay opening for 3 sec If an alarm is continual or power supply fails the individual point relay contacts are open permanently switching ON indicator 2 for 3 sec or permanently according to the state of the individual point relay contacts if the automatic thresholding was performed switching ON indicator 3 for 3 sec or permanently according to the state of the individual point relay contacts if the automatic thresholding was performed 5 2 4 Setup Mode Setup mode is switched on by the action 5 6 sec It is set automatically The periodical switching on the indicators 1 2 3 means the sensor change in the standby state then all the indicators are switched off for 3 sec after that the action repeats To leave the setup mode and to transmit in the standby mode it is necessary to perform the action lt 3sec when all three indicators are switched off The setup mode comprises three modes S
15. eps operating at an ambient temperature from 40 to 65 C and relative humidity up to 98 at the temperature 35 C 3 SPECIFICATIONS 3 1 The detection zone DZ dimensions are given in table 3 1 and fig 3 1 Table 3 1 Mounting on th r Mounting on the wall ae ie nee stile a i a Mounting on the DZ dimensions Distance of Distance of Distance of Distance of level the sensor the sensor the sensor the sensor Mounting between the between the between the between the height fence fence fence fence 0 85m V 0 25m V 0 15m V 0 25m V 0 15m Height h 0 5 1 5m 0 5 1 5m 0 5 1 2m 1 4 1 6m Notes 1 The maximum sector s length for the variants a and b depends on the dimensions of the fence V 2 For the variant b wall mounting there are the values b not of all the DZ width but its half from the sector s axis to the border 3 During the mounting on the level b 4 m the DZ width is given for the maximum sensor sensitivity ANN b a mounting on the upper part of the fence b mounting on the wall c mounting on the level ground connection Fig 3 1 Detection zone of the sensor Forteza Lamp 3 2 The sensor generates an alarm in the cases an intruder moves in the DZ at a speed of 0 1 6m sec with probability 0 98 minimum there is no signal from Tx supply voltage is below standard there is no supply voltage there is an attempt to demount the sensor the
16. f Tx and Rx antennas vertically and horizontally with the attachment fitting Every indicator 1 2 3 in this procedure has five scales of glow frequency from periodic switching on with low frequency infrequent blinking to continuous glow The increase of the indicator glow frequency corresponds to the increase of the amplitude of Rx input signal If to consider all three indicators the indication of input signal increase occurs from left to right i e indicator 1 is a low order digit of this ruler The continuous glow of 3 indicator means that an input signal is large and the amplifier is in saturation At the same time it is necessary to disalign the transmitter antenna turning up Too small signal or no signal is indicated by the disconnection of all indicators While the alignment it is necessary to get the maximum amplitude of Rx input signal providing the reserve from the saturation of Rx amplifier The maximum acceptable level is a result of the constant glowing of the indicators 1 2 and the blinking with the maximum frequency of the indicator 3 Notes The maximum received signal is generated when the Rx and Tx antennas are situated in parallels There are some separated maximums of the received signal because of the reflection from walls obstacles and surface These maximums are false Follow the actions to perform the alignment a Enter Alignment mode from the Setup mode
17. g 1 d Check the synchronization with the indicators The synchronization is performed successfully in the cases Two indicators 1 and 2 glow periodically for the sector generated Tx with the letter A All three indicators glow periodically for the sector generated Tx with the letter Be e Leave Synchronization mode and enter Setup mode action 5 6 sec If during synchronization Rx synchronizes with the features alien to its own Tx or it does not synchronize at all it means that Tx of another sector prevents it or there is not beaming of its own This situation is possible in the following cases detection zones axes of adjacent sectors form an acute angle adjacent sectors are different in length the synchronized Rx is situated in the place e g the angles or pockets of obstacles where there is a signal deformation 11 power supply is OFF on its own transmitter its own transmitter is not positioned In this case it is necessary to switch off the power supply of other transmitters which can influence on the synchronization after that carry out this synchronization 5 2 4 2 Alignment mode While alignment two tasks are solved simultaneously more accurate positioning of the transmitter and the receiver of one sector to each other areceived signal level adjustment providing the sensor operation The alignment is carried out by the turn o
18. ine integrity and the doesn t is broken YIIP power supply voltage operate CONTROL 2 The power supply voltage is less than the norm 12 STORAGE 12 1 The sensor should be stored in the package in warehouses at an ambient temperature 5C 50 C and relative humidity 85 maximum 12 2 During the storage the influence of hostile environment should be prevented 13 TRANSPORTATION 13 1 Packaged sensors can be transported by any transport if by plane in pressurized modules if they are transported in covered cars holds or covered bodies they can be transported at the distance up to 10 000 km 13 2 The boxes should be placed to prevent their shifting or fall in case of jolts and blows 22 Microwave Intrusion Sensor FORTEZA LAMP Certificate The purpose of the sensor and its specifications are given in the corresponding items of the user manual 4372 43071246 058 1 DELIVERY KIT 1 1 The delivery kit is given in Table 1 Table 1 Ne Name and symbol Quantity i Midle transmitting unit No 2 Tx No 5 Extreme transmitting unit No 1 Tx No 3 Middle receiving unit Ne 2 Rx No Extreme receiving unit of the N 4 sensor Ne 1 Rx No 5 Case of the lamp 1 item on every Tx or Rx unit 6 Tx cable 1 item on 2 Tx or 1 Tx 7 Rx NC cable 1 item on 2 Rx or 1 Rx 8 User manual and certificate 1 item for the ordered kit 9 Package Ne 10
19. ions for the sensors operation prepare a sector 13 install the sensors units connect the sensors synchronization adjustment setup of the thresholds sensitivity The rules and the methods are given in 1 8 and 9 5 3 2 The receiving and the indication of the alarms are realized by receiving transmits devices and systems providing the check of the sensors output circuits of the contact type contact breaking 5 3 3 During the operation the remote control of the sensors can be performed too The check is realized by the duty operator of the signal generation RC As a response the sensors generate an alarm It proves the sensors availability and the running order of the loop circuit The user determines the check periodicity 5 3 4 During the sensor operation in the summer time at an ambient temperature higher than 30 C it is recommended strongly to disconnect the lighting to prolong the light emitting diodes lifetime 5 3 5 Besides there it is necessary to perform periodically the maintenance check of the sensors and their servicing The check periodicity and maintenance are given in 1 10 14 6 SENSOR STRUCTURE 6 1 The external view of the medium Rx for the sensor 2Rx without lamp case is given in fig 6 1 O90 z f go WE Be i ae 2 processing base board O 3 cable 4 4 receiving antenna of the channel I 5 receiving antenna of the aSa i a
20. m The other person an operator checks the training process by indicators on the Rx base board The training must be carried out preventing all noise movement of outsiders or an operator near a detection zone or in it traffic movement near the zone etc It can cause the sensor training for noise but not for an intruder For the thresholding turn the thresholds controller of the channel at the angle 45 towards or After the performance of this action the thresholds will be installed in accordance with the position of the thresholds controller The turn towards reduces the threshold of action and increases the sensor increases the threshold of operation and reduces the 33 sensitivity The turn towards sensors sensitivity After the manual adjustment any actions to transmit the sensor in Standby mode is not necessary The infrequent blinking of the indicator 3 is a result that the sensor is situated in Standby mode with the performed manual adjustment It is recommended to begin the manual adjustment from the position During the crossings see below check an alarm of the sensor by the switching on the indicator 3 for the time 3 sec If an alarm is absent a higher sensitivity is installed with the turn of the controller at a small angle and then the check crossings are performed again The period repeats until an alarm is generated 5 3 Sensor Operation 5 3 1 Follow the act
21. nit rain and snow wind at a speed of 10m sec maximum if it doesn t provoke the vibrations of the fence on which the sensor is installed the height of grass is up to 0 3m for the ground connection the height of snow is 0 6 m maximum for the ground connection 3 11 The input circuits are protected from the temporary overvoltage up to 900 V provoked by the pickups in the supply and communication lines during the storm discharge 3 12 Operating frequency is 9375 70 MHz 3 13 The impulse power of the sensor beaming is 10 m Watt the mean beaming power with the porosity of the microwave impulses is 0 35 m Watt 3 14 The remote control characteristics de voltage is 5 30 V relative to supply duration is 1 sec min current consumption is 2 ma max 3 15 The international protection is IP43 3 16 The units dimensions without cases of the lamps mm max Rx and Tx 90x190 3 17 The units weight without cases of the lamps kg max Rx and Tx 0 3 3 18 The sensor average lifetime is 8 years 4 SENSOR COMPONENTS 4 1 The delivery kit of the sensor Forteza Lamp comprises Middle transmitting unit 2Tx quantity at the order Extreme transmitting unit 1 Tx quantity at the order Middle receiving unit 2 Rx quantity at the order Extreme receiving unit 1 Rx quantity at the order Case of the lamp 1 item for every Tx and Rx unit the type of the case
22. the sensors units through the pressure seals of the junction boxes and cut off The cables of the sensors are marked see table 8 1 17 Table 8 1 Re NC cable Wate iP o Brown Green ae eee ee ee Pink r Bie f Ne Red J o o Notes power supply of the sensors CONTROL power supply of the LED RC remote control signal 5 30 V NC I normally closed relay contacts of the individual point relay for I channel of the signal processing NC II normally closed contacts of the individual point relay for II channel of the signal processing 18 ax e am Tx cable Rx NC cable Tx cable On suppl MiNI unit et a Oh supply 24VDC unit Ho iii NCI NCI On th control NCII m panel NCII RC Light control 7i_ DN ofr Notes L T terminator of the control panel 2 The recommended type of the cable for supply HOSVV F 2x1 0 for the signal lines UTP 3 Two supply units SU as a variant Fig 8 1 Two perimeter sectors connection of the sensor FORTEZA LAMP 9 SENSOR SETTING UP PROCEDURES AND ADJUSTMENT 9 1 Setting up Procedures 9 1 1 Check the supply circuits and alarm lines right connection 9 1 2 Switch ON the sensor power supply 9 1 3 Take off the lamps bowls from the cases of the sensors 9 2 Sensors Setup 9 2 1 Transfer the sensor in Setup mode and adjust according to 1
23. ynchronization mode Alignment mode Thresholds installation 10 ATTENTION It is necessary to follow all the actions in order for the right setup To pass in Synchronization mode it is necessary to perform the action lt 3sec during the indicator s glowing 1 To pass in Alignment mode it is necessary to perform the action lt 3sec during the indicators glowing 1 and 2 To pass in Thresholds installation mode it is necessary to perform the action lt 3sec during the indicators glowing 1 2 and 3 To leave a mode perform the action 5 6 sec 5 2 4 1 Synchronization mode Rx unit should correspond to Tx unit letter A or B Thats why the synchronization is necessary The synchronization is performed when Tx and Rx antennas are adjusted Follow the actions to perform the synchronization a Install the necessary frequency letter A or B according to the sectors generation principle see 1 5 1 3 The jumper is installed the letter A the jumper is removed the letter B The jumper condition changing is performed by the disconnection and the next unit power up Note It is recommended to disconnect the power supply by the white colored wire removing from the socket b Enter Setup mode action 5 6 sec c Enter Synchronization mode action lt 3 sec during the indicator s glowin