Gebrauchsanweisung Leica CV 5030
Contents
1. Serial number Order no The package contents are fragile and must be handled with care Indicates the correct upright position of the package Leica HI1220 Flattening Table Instrument surfaces which become hot during operation are marked with this symbol Avoid direct contact with these surfaces they may cause burns The CE labeling shows that the product corresponds to one or more applicable European directives Environmental protection symbol of the China RoHS directive The number in the symbol indicates the Environment friendly Use Period of the product The symbol is used if a substance restricted in China is used in excess of the maximum permitted limit Symbol for labeling electrical and electron ic equipment in accordance with Section 7 of the German Electrical and Electronic Equipment Act ElektroG ElektroG is the law regarding the sale return and environ mentally sound disposal of electrical and electronic equipment 1 Important Information 1 2 Qualification of personnel e The Leica HI1220 may be operated by trained laboratory personnel only e Alllaboratory personnel designated to operate this instrument must read these Instructions for Use carefully and must be familiar with all technical features of the instrument before attempting to operate it 1 3 Intended use of instrument The HI1220 microscope slide flattening table for paraffin sections is a heating plate with
2. high heat output and precise temperature control The HI1220 is suitable for flattening and drying cut tissue samples in all fields of biomedical research and routine diagnostics A Any other use of the instrument is considered improper Failure to adhere to these instructions may result in an accident personal injury damage to the instrument or accessory equipment Proper and intended use includes compliance with all inspection and maintenance instructions along with the observance of all instructions in the Instructions for Use 1 4 Instrument type All information provided in these Instructions for Use applies only to the instrument type indicated on the cover page A nameplate indicating the instrument serial num ber is attached to the rear side of the instrument Fig 1 Fig 1 is provided as an example only and shows a valid nameplate for this instrument with the necessary in formation about instrument type and power requirement The precise data for the various versions is specified in Chapter 3 1 Technical data Instructions for Use V 3 2 RevE 02 2013 2 Safet 2 1 Safety notes other Leica products and access its internal components Residual risks e The safety and caution notes in this chapter must be observed at all times e Be sure to read these notes even if you are already familiar with the operation and use of e The protective devices located on
3. of the power cable an extension cable must NOT be used e The substrate must be largely vibration free and have sufficient load capacity and rigidity for the weight of the instrument e Avoid impacts bright direct light and excessive temperature fluctuations e The instrument must be connected to a suitable power socket Use only the provided power cable which is intended for the local power supply Unpacking and setting up the HI1220 Set the carton on a flat surface cutthrough the adhesive tape Fig 2 and open the carton Fig 3 Instructions for Use V 3 2 RevE 02 2013 4 Instrument Setup 42 Unpacking and setting up the HI1220 continued Remove the accessories and carefully lift the Hold the instrument firmly with one hand pull off instrument out of the carton Fig 4 both foam sections Fig 5 and remove the dust cover 4 3 Setting up the power supply e Before connecting the power cable make sure that the power switch 3 on the rear of the instrument Fig 6 is switched to 0 OFF e Use the instrument with the provided power cable only e Insert the connector of the power cable Fig 5 2 into the connection socket 4 and plug the power plug into the power socket Leica HI1220 Flattening Table 11 5 Operation 5 1 Control panel fields on the instrument 5 POWER LED Is illuminated when the instrument Is switched on with the main power switch 6 SET Indicates
4. reinsert the fuse holder and press it into place 14 Instructions for Use V 3 2 RevE 02 2013 7 Warranty and Service Warranty Service information Leica Biosystems Nussloch GmbH guarantees that the contractual prod uct delivered has been subjected to a comprehensive quality control procedure based on the Leica in house testing standards and that the product Is faultless and complies with all technical specifications and or characteristics warranted The scope of the warranty is based on the content of the concluded agreement The warranty terms of your Leica sales organization or the organization from which you have purchased the contractual product shall apply exclusively If you require technical service or replacement parts please contact your Leica sales office or dealer who sold the product The following inputs are required e Model name and serial number of the instrument e Location of the instrument and name of a contact person e Reason for the service call e Date of delivery Decommissioning and disposal Leica HI1220 Flattening Table The instrument or parts of the instrument must be disposed of according to existing applicable local regulations Special attention should be paid to the lithium cell of the electronic circuit board 15 Notes 16 Instructions for Use V 3 2 RevE 02 2013 Leica BIOSYSTEMS www LeicaBiosystems com Leica Biosystems Nussloch GmbH Heidelberge
5. rise once a lit after reaching the set temperature observe the temperature display e The target value remains saved both when the instrument is switched off RUN STOP A key or power switch and in case of power failure and disconnection from the power supply 5 4 Switching off the instrument e The instrument can be switched off by pressing the RUN STOP key e You do not have to switch the main power switch on or off each time for everyday a routine use Leica HI1220 Flattening Table 13 6 Cleaning and Maintenance 61 Cleaning the instrument e Before cleaning the instrument turn off using the power switch Fig 6 3 and disconnect from the power supply The instrument has a continuous front panel and no lateral cooling slots so the surfaces are smooth and easy to clean e Allsurface materials are resistant to common laboratory detergents 1 The instrument must be switched off and have cooled down for cleaning N Do not use organic solvents e g alcohol or xylene 6 2 Replacing fuses Switch the unit off and unplug it Use only the supplied replacement fuses Both fuses must have the same rating check the imprint Fuses must always be switched out in pairs e Insert a small screwdriver into the cutout Fig 8 11 and carefully pry out the fuse insert 12 e Remove the fuse holder and replace the de fective fuses with two new ones 13 e Then
6. setting up the Hl1220 cnocnccicnccnocccnconecconconanconacnonconacnonconcononconconnconronas 10 43 Selting up the DOWErSURp Manara 11 g Operation a 12 5 1 Control panel fields on the instrUMent ccccccecssescssesssesesscscesesssseseeessesesessesesesseneesaeseseeen 12 5 2 Switching the instrument ON ccceseccsescssesesesesseseseeecsesesaesesesecsesesacsesesesensesacsesesesanstersatsesetens 12 ba Senna the tempera race en 13 e e OU iO EIA 13 6 Cleaning and Maintenance c cccscssssssssssssssssesssseesessesesseeseseesesasseeansaeseesneas 14 61 Cleaning the InstruMent c ccccsscessssssscsesseseseeessesesecsssesesassesesessesesassesesasensesassusesasenseasanseses 14 0 TRCN NE IS aan 14 7 Warranty and Service cccccssssssssssssssssssssseesessssersesseseesesassessesaeseesesassesansansneansas 15 4 Instructions for Use V 3 2 RevE 02 2013 1 Important Information 11 Symbols and their meanings Warnings appear in a gray box and are marked by a warning triangle i 5 START atal T REF Notes i e important user information appear in a gray box and are marked by an information symbol Numbers and parentheses refer to item numbers in the illustrations Function keys to be pressed on the instrument control panel are in bold print capital letters Manufacturer Observe the instructions for use
7. sure to comply with the following instructions and warnings Please note that electrostatic charge may result through direct or indirect contact with the Leica HI1220 Instructions for Use V 3 2 RevE 02 2013 Instrument Components and Specifications 3 1 Technical data Nominal supply voltages Nominal frequency Nominal power Main fuse Dimensions Empty weight Relative humidity IEC 1010 classification Operating temperature range Temperature control range Operating elevation IP protection class IEC 60529 Leica HI1220 Flattening Table Two factory preset voltages not user adjustable 100 120 VAC 10 230 240 VAC 10 50 60 Hz 350 VA 2 melting fuses 5x20 mm UL approved For 100 120 V 5x20 mm 2x T 5A L250 VAC For 230 240 V 5x20 mm 2x T 2 5A L250 VAC 350x310x 100 mm 3 6 kg w o packaging 20 80 non condensing Protection class 1 Pollution degree 2 Overvoltage category II 15 C to 40 C Room temperature to 75 C maximum of 2000 m above sea level IP20 4 Instrument Setup 4 1 4 2 10 Installation site requirements e When installing the power cable always be sure to route It so that it cannot contact the heated surfaces of the instrument at any time e The power socket to which the instrument is to be connected to has to be located near the instrument and easily accessible e The power supply must be at a distance no greater than the length
8. the instrument and the accessories must not be removed or modified Only qualified service personnel authorized by Leica may repair the instrument e The instrument has been designed and constructed with the latest state of the art technol ogy and according to recognized standards and regulations with regard to safety technology Operating or handling the instrument incorrectly can place the user or other personnel at risk of injury or can cause damage to the instrument or other property The instrument may be used only as intended and only if all of its safety features are in proper working condition Malfunctions which could impede safety must be remedied immediately e Only original spare parts and permitted original accessories may be used These Instructions for Use include important instruc tions and information related to the operating safety and maintenance of the instrument The Instructions for Use are an important part of the product and must be read carefully prior to startup and use and must always be kept near the instrument i These Instructions for Use must be ap propriately supplemented as required by the existing regulations on accident prevention and environmental safety in the operator s country Leica HI1220 Flattening Table This instrument has been built and tested in accor dance with the safety requirements for electrical equipment for measurement control and laboratory use To maintain this
9. I1220 Flattening Table These are determined only by the contract provisions agreed between ourselves and our customers Leica reserves the right to change technical specifications as well as manufacturing process es without prior notice Only in this way is it pos sible to continuously improve the technology and manufacturing techniques used in our products This document is protected under copyright laws All copyrights to this documentation are held by Leica Biosystems Nussloch GmbH Any reproduction of text and illustrations or of any parts thereof by means of print photocopy microfiche web cam or other methods includ ing any electronic systems and media requires express prior permission in writing by Leica Biosystems Nussloch GmbH For the instrument serial number and year of manufacture please refer to the nameplate on the back of the instrument Leica Biosystems Nussloch GmbH Table of Contents A 5 11 Symbols and temen OS uscar can osar ceuta 5 12 Qualification of EFS OPIN isso corno oie 6 13 Intended use of WSU UNG DE urraca 6 IE SE A 6 2 Daiana 7 F SE ii 21 ea E OO on 7 22 WV ITUNES A Pei e A E 8 3 Instrument Components and Specifications 2u222222222002220002220n0n22nnnnnnnnnnnnnne 9 31 A e o A een EEE ArERa Ener ErTEecTTEETerEE 9 AA 10 4 1 Installation site reQuir Ment cccccccessssessssssscssesesecsscsssecsessesesseseesessuseesessesauseseesaesessesasees 10 4 2 Unpacking and
10. Leica BIOSYSTEMS Instructions for Use Leica H11220 Flattening Table Ce Instructions for Use V 3 2 RevE English 02 2013 Order No 14 0423 80101 NOTE The information numerical data notes and value judgments contained in this manual represent the current state of scientific knowledge and state of the art technology as we understand it following thorough investigation in this field We are under no obligation to update the pres ent manual periodically and on an ongoing basis according to the latest technical developments nor to provide our customers with additional cop ies updates etc of this manual To the extent permitted in accordance with the national legal system as applicable in each individual case we shall not be held liable for erroneous statements drawings technical illus trations etc contained in this manual In particu lar no liability whatsoever is accepted for any financial loss or consequential damage caused by or related to compliance with statements or other information in this manual Statements drawings illustrations and other information regarding the contents or technical details of the present Instructions for Use are not to be considered warranted characteristics of our products atal Leica Biosystems Nussloch GmbH Heidelberger Str 17 19 D 69226 Nussloch Germany Phone 49 0 6224 143 0 Fax 49 0 6224 143 268 Internet http www LeicaBiosystems com Leica H
11. condition and ensure safe operation the user must observe all notes and warnings con tained in these Instructions for Use e The instrument s CE certificate can he A found on the Internet at http www LeicaBiosystems com 2 Safety 2 1 2 2 Safety notes continued e Inorderto properly service the instrument it is indispensable to read the User Manual before switching on the instrument and to familiarize yourself with all technical details e Before connecting the instrumentto the line voltage ensure that the electrical power require ments of your laboratory match the values on the nameplate of the instrument e When installing the power cable always be sure to route it so that it cannot contact the heated surfaces of the instrument at any time e The instrument is designed for indoor use only e The instrument must be switched off and unplugged from the power supply during all repair and service work e During operation the instrument surface can be very hot Risk of injury Do not store any combustible and flammable substances near the instrument Warnings The safety devices installed in this instrument by the manufacturer only constitute the basis for accident prevention Operating the instrument safely is above all the responsibility of the owner as well as the designated personnel who operate service or repair the instrument To ensure trouble free operation of the instrument make
12. r Stra e 17 19 D 69226 Nussloch Phone 49 6224 143 0 Fax 49 6224 143 268 Web www LeicaBiosystems com
13. the selected target tempera ture 7 Setkey lower temperature 8 Set key increase temperature 9 RUN STOP Switch instrument on or off 10 Display 5 2 Switching the instrument on e Switch on the instrument with the power switch on the left rear panel of the instrument Fig 6 3 e The green LED display POWER on the front panel is then illuminated 12 Instructions for Use V 3 2 RevE 02 2013 5 Operation 5 3 Setting the temperature e Pressing the RUN STOP button on the front panel brings the temperature of the instrument to the latest stored target value The displayed temperature corresponds to the current actual value e The set target temperature is shown in the display Fig 7 10 To adjust to the desired temperature hold down the corresponding set key Fig 7 7 8 The display changes slowly for the first 8 digital steps then more quickly after that The temperature display refers to the target value After the desired temperature is reached release the set key The displayed value is saved automatically This stored target value will continue to be displayed for about 2 seconds then the current actual temperature display will appear again e The target temperature can be checked by pressing the SET key Fig 7 6 tle Therefore extremely temperature sensitive samples should not be positioned until N After changing the target temperature the temperature may temporarily