Home
ETCR6200 Manual
Contents
1. D AC DC Leakage Current Clamp Meter ETCR Car Leakage Current Clamp Meter ETCR 6200 USER MANUAL ETCR Electronic Technology Co Ltd CONTENT Warns RT 1 I INMOGUCTION2 ati aos 3 Il Range ANd ACCUACY ee eeeeeeesesseceeeeeseeeesesseeescesaceeseseeeeaceetaeeeeees 4 lll Electrical Signs naaa rain 4 IV Technical Specifications siii toi 5 Y Structure of the Leaker cio i nica 7 VI CCD Dts Bley snes ai sates eas tus SAP Td Sn 8 VII Operating Metodo aos 8 Le Startup Shutdown ses ictericia ISI teen ees 8 LAC DC SWI e a A a camadas E vao 8 By ORTA 9 4 Current Measurement aseina aan e e aat 9 Peak Holding pinih aa anaha enra 11 6 Hold Storage and Access Readid8 ooononocnocnocnncconnconcnnconananonncanon 11 T Data Upload ida 12 VII ADpIICation A IX How to Change Battery ati X Accessories A Warning A Thank you for purchasing our company s ETCR6200 AC DC Leakage Current Clamp Meter for better use of this product please Read carefully the user s manual Follow strictly safety rules and notes listed in this manual u Under any circumstances please pay special attention to your safety in the course of using this leaker u Give heed to label texts and symbols on panel and back plate of this leak er u Please be more careful if the line voltage is above 60VDC or 30VAC u When test AC current the wire should be in the jaw center otherwise the error will inc
2. DC key to choose the kind of measurement 3 Adjust zero 4 Release the toroid lever to open clamp mouth and clamp measured con ductors 5 Read LCD display data In case OL A symbol was displayed it means that current of measured line is beyond the maximum limit of this leaker with this case please choose leaker with much higher range limit Thelocation of the wire Note For your safety when measure the large current after the correct operation put the in N strument removed from the tested wire In locations with difficulty to read out data please use the data holding function If DH symbol dis played please discharge data holding state first and then do the test 10 5 Peak Holding Pressing HHOLD key continually in the course of measurement More than 3 seconds the leaker will capture current peak values of lines in this period of time release the key it then will return to measuring state 6 Hold Storage and Access Reading 1 Pressing HOLD key for a short time in the course of measurement less than 3 seconds DH symbol will display the leaker will hold current mea suring data and automatically stored in the memory with a unit ID press HOLD key again to release the hold state and the leaker continues its measuring in case stored data reached to 60 groups press HOLD key again the FULL symbol will disp
3. and automatic shifting It is apply to car leakage rapid detection consumed current detection quickly find the fault of the wire broke leakage equipment fled electric line contact with iron measuring the motor inrush current and alternator charging current etc It could be widely use in those fields as car repair car leave factory test car parts test the current detection in telecommunication room electric power overhauling meteorology oil detection etc It has those functions as peak holding data holding and data storage It obtains one RS232 interface communication cable and software through the computer it can online real time monitoring historical query dynamic display MIN AVG MAX indication alarm setting and indicating data reading saving and printing Il Range and Accuracy Function Measure Range Accuracy Resolution DC current 0 0mA 60 00A DC 2 rdg 5dgt 1mA AC current 0 0mA 60 00A DC 2 rdg 5dgt 1mA Condition 23 C 5 C below 75 rh wire in the center of jaw lll Electrical Signs Extremely dangerous Operators shall strictly keep to safety rules otherwise there would be dangers of electric shock to cause personal injuries or casualties Dangerous Operators shall strictly keep to safety rules otherwise there would be dangers of electric shock to cause personal injuries or casualties Warning Operators shall strictly keep to safety rules otherwise personal injuries or
4. and need to be replaced 2 Press POWER key to shut down the leaker Before opening the battery cover please confirm the leaker is in off position and then replace with qualified new battery special attention shall be paid to the polarity of battery at last cover battery cover plate 13 X Accessories Clamp tester 1 pc USB Com cable 1 pc Software 1 disk Battery 6F22 9V 1 pc User Manual 1 copy Warranty card Certification Packing box 1 copy 14 A Manufactured by ETCR Electronic Technology Company Address F 3F No 4 Pengshang Zhifu Road Jiahe Baiyun District Guangzhou Guangdong China Post Code 510440 Tel 86 20 62199556 62199554 Fax 86 20 62199550 E mail info etcr cc Website www etcr cc
5. as to be changed Weight 180g including the battery Working Cur cent Max 20mA Humiture 10 C 50 C below 80 rh Limit Temper ature Error 10 C 0 C and 40 C 50 C within 2 rdg Humiture Sto 10 C 60 C below 70 rh rage Insulating AC 3700V rms between the alloy of the clamp and Strength the housing Applicable 1EC1010 1 1EC1010 2 032 pollution 2 CAT II 6 safety rules 600V Meter 1pc toolkit 1pc RS232 communication line Accessories 1pc disk 1pc case 1pc V Structure of the Leaker Clamp Totoid opening lever POWER key LCD USB interface DC current positive input indication HOLD Key AC DC switch key ZERO Key 10 The screw of connect the upper and rower cover together 11 The screw to fix the battery cover 12 Battery cover SIDA VI LCD Display 1 DC indication 1 1 t 2 AC indication 3 AC indication 0 Ads 4 Low battery symbol ll ACH O O Ef 5 Data hold indication zal 6 Stored data code 7 Unit of current indication 8 Value of current VII Operating Method 1 Startup Shutdown gt 7 E m8 Press POWER key to start up LCD will begin to display Press the POWER key again the leaker will shut down After starting up for 5 minutes LCD will flick notes that the leaker wil
6. equipment damages might be caused Double insulation AC lee gt PIS DC IV Technical Specifications Model ETCR6200 A Measurement of AC DC current leakage cur Function rent repairing the car circuit Power Supply Zn Mn dry battery 6F22 9V continuous use for 30h Test Mode Clip on CT noncontact measurement Clamp Size 25mmx35mm Measurement OmA 60 0A AC DC Range Resolution 1mA AC DC Accuracy 2 rdg 5dgt 23 C 5 C below 75 rh Display Mode Four digits LCD display Dimension LWH 168mmx65mmx34mm LCD Dimen 35mmx21 5mm display domain 32mmx15mm sion Sampling Rate 2 times s Frequency AC 45Hz 400Hz Polarity Indi DC current auto identified and display cation Test Position Tested wire in the jaw center Range Shift Automatically 255 Line Voltage Do not exceed AC 600V RS232 Inter Data stored in the memory of the meter via RS232 face upload to PC Com Configure Baud rate 9600 data bit 8 stop bit 1 check bit NONE Data Memory 99units FULL blinks when the memory is full Reading Hold DH indicating the reading is hold Out of Range OL indicating the current is out of range Auto Power off 5 minutes after power on it will power off automati cally to lower the power consumption Indicating the battery voltage is lower than Battery Voltage 7 2V Then the battery h
7. l shut down automatically after flickering for 30s it will shut down formally to reduce battery consumption In case you have pressed POWER key when LCD was flickering the leaker will continue to work for 5 minutes If LCD was very dark after starting up it might be caused by low voltage battery in this case please change battery immediately 2 AC DC switch After startup instrument default into DC current testing Press to switch the AC and DC current LCD display DC indicates DC current display AC indicates AC current 8 3 Reset Before measuring long press the ZERO key to reduce the residual mag netism to zero and then conduct measurement Rational usage of this adjust zero function will make the results more accu rate For example after boot before measurement we can take the jaw close to the DC current wire LCD will show an inductive current Adjust ZERO key to calibrate to deduct the inductive value I i i amp 4 Current Measurement casualties High voltage extremely dangerous Operators shall strictly observe safety rules otherwise there would be risk of electric shock to cause personal injuries or damages Dangerous Please don t use it to measure current A higher than 60A otherwise there would be risk of electric shock to cause personal injuries or equipment 9 1 Power on 2 Switch AC
8. lay which means storage memory is full press HOLD key to cancel FULL flickering and mode return to measuring 2 Press HOLD POWER keys to enter into data access mode and display Unit 1 storage data automatically and then press HOLD key again to turn the page of stored data NULL will display when there is no data in stored in the memory press POWER key to exit data access mode 3 After entering into data access mode press HOLD seconds will clean up all stored data When the leaker displaying dEL key for more than 3 symbol it means that it has finished cleanup process and then return to measuring state automatically 11 7 Data upload Make good connection of computer and the tester with RS232 communica tion wire switch on the tester and run monitoring software In the soft ware directory setting the editor communication settings serial num ber COM1 COMS If the connection is successful then it can read the stored historical data upload to company preserve and print The monitoring software has those functions as online real time monitoring historical query dynamic display MIN AVG MAX indication alarm setting and indicating data reading saving and printing VIII Application Car leakage usually makes the car starting difficult or the appliances ab normal
9. operation such as the lights dim central controlled lock can not open The driver often want to replace the battery when the car has no electricity Actually the following situations cause the battery empty 1 The appliances are not shutdown such as headlight isn t turn off 2 The faults of appliance wiring harness control unit and sensor 3 Wires contact with iron 4 The motor do not generate electric 5 The battery plate short circuit or oxidation and fall off If the reason is 1 2 3 or 4 replay the battery not only waste repair cost but also not solve the essential problem Use the ETCR6200 Car Leakage Current Clamp Meter there is no need to power off and clearing to measure 12 the battery standby current the appliance standby current and working cur rent the motor charging current safe and rapid to find out the fault location save time and cost When the appliance shutdown clamp the positive power line measure the leakage current and standby current when the ap pliance startup clamp the positive power line measure the working current IX How to Change Battery Warning It is dangerous to carry out test when the battery cover plate was not on its position Please pay attention to the polarity of battery to A avoid damaging the leaker Chang the low battery in time If you expect not to use the meter for a long time please get off the battery to storage 1 symbol means the battery is undercharge
10. rease u Please don t place and store this leaker in hot and humid condition loca tions with moisture condensation and under direct sunlight for a long time u In case voltage of battery was low please replace batteries u If you expect not to use the leaker for a long time please take out batte res u When changing batteries please pay attention to the polarity of battery Je u Use disassembly and maintenance of this leaker shall be operated by authorized personnel u In case dangers would occur if continue to use a faulty leaker please stop to use it and seal it for safekeeping immediately and then send it for disposal of authorized agency u Users shall carry out operation based on danger signs A on leaker and manual u Users shall carry out safety operation based on instructions listed in this manual e g 7 and danger signs on this manual I Introduction ETCR6200 AC DC Leakage Current Clamp Meter also named Car Leakage Current Clamp Meter Car Standby Current Clamp Meter Car Inrush Current Tester Car Charge Current Tester It is specially designed for online mea surement of DC AC leakage current current below 600V by adopting up to date CT technology and digital integration technology It is specially suitable for measure car standby current leakage current inrush current Itis a product with the characteristic of relatively small size high accuracy strong anti interference capability
Download Pdf Manuals
Related Search
Related Contents
here. - Timm IQ Plus™ WSSV Kit with POCKIT System 平成14年那審第37号 漁船大進丸運航阻害事件 〔簡易〕 二審請求者 DP-2310/3010/3510/4510/6010 Operating Instructions Compro TN50W surveillance camera Copyright © All rights reserved.