1. It is necessary to stop the air conditioner and dis connect the power supply before cleaning Cleaning the indoor unit and remote controller e Use a dry cloth to wipe the indoor unit and remote controller e Acloth dampened with cold water may be used on the indoor unit if it is very dirty e The front panel of the indoor unit can be removed and cleaned with water Then wipe it with a dry cloth e Do not use a chemically treated cloth or duster to clean the unit e Do not use benzine thinner polishing powder or similar solvents for cleaning These may cause the plastic surface to crack or deform Cleaning the air filter A clogged air filter reduces the cooling efficiency of this unit Please clean the filter once every 2 weeks 1 Lift the indoor unit panel up to an angle until it stops with a clicking sound 2 Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder then pull it downwards 3 Remove the AIR FILTER from the indoor unit e Clean the AIR FILTER once two weeks e Clean the AIR FILTER with a vacuum cleaner or water then dry it up in cool place MAINTENANCE m Air freshening filter Air freshening filte r PESA GP SF
2. Open and lift the front panel up to an angle until it remains fixed with a clicking sound Push the AUTO button andthe air conditioner will run in AUTO mode Manual Close the panel firmly to its original position control button NOTE For gt 16000 21000Btu h Models The COOL mode on the control board is only provided for testing purposes 4 ADJUSTING AIR FLOW DIRECTION e Adjust the air flow direction properly otherwise it might cause discomfort or cause uneven room temperatures e Adjust the horizontal louver using the remote controller e Adjust the vertical louver manually Adjusting the Vertical Air Flow Direction up down The air conditioner automatically adjusts the vertical air flow direction in accordance with the operating mode To set the vertical air flow direction Perform this function while the unit is in operation Keep pressing the AIR DIRECTION button on the remote controller to move the louver to the desired direction e Adjust the vertical air flow direction to the desired direction e In subsequent operations the vertical air flow is automatically set in the direction to which you adjusted the louver by pressing the AIR DIRECTION button To set the horizontal air flow direction left right Adjust the vertical louver manually using the lever on the left or right side of the vertical louver arm Depending on model Take care not to catch fingers on the fan horizontal lo
3. 4 Remove the air freshening filter from its support frame The installation and removing method of the air freshening filter is different depending on the models see the pictures marked Qand 2 on the left e Clean the air freshening filter at least once a month and replace it every 4 5 months e Clean it with vacuum cleaner then dry it in cool place 5 Install the air freshening filter back into position 6 Insert the upper portion of air filter back into the unit taking care that the left and right edges line up correctly and place filter into position Maintenance If you plan to idle the unit for a long time perform the following 1 Operate the fan for about half a day to dry the inside of the unit 2 Stop the air conditioner and disconnect power Remove the batteries from the remote controller 3 The outdoor unit requires periodic maintenance and cleaning Do not attempt to do this yourself Contact your dealer or servicer Checks before operation e Check that the wiring is not broken off or disconnected Check that the air filter is installed e Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shoc
4. and soaking of household furniture Do not use strong detergent Ensure that the installation bracket of Always insert the filters such as wax or thinner Use the outdoor appliance is not damaged securely Clean filter once a soft cloth for cleaning due to prolonged exposure every two weeks e Appearance may be e If bracket is damaged there Operation without filters may deteriorated due to change is concern of damage due to cause failure of product color or falling of unit scratching of its surface 0 Use caution when unpacking If water enters the unit turn f the unit off and disconnect and installing Sharp edges the power contact a qualified service technician Do not place heavy object on the power cord and take care so that the cord is not compressed could cause injury e There is danger of fire or electric shock PARTS NAMES INDOOR UNIT 3 Air inlet 1 Y V L 4 Air outlet OUTDOOR UNIT 6 co MY Air inlet Air outlet DISPLAY PANEL NOTE The display panel on the indoor unit would look like one of following Infrared signal receptor TIMER OPERATION O o PRE DEF O Infrared signal receptor OPERATION AUTO TIMER O O O ECON PRE DEF O Q INDOOR UNIT Front panel frame Front panel Air filter Horizontal air flow grille Vertical air flow louver Room t
5. operate unit with horizontal louver in closed position When the air conditioner is connected to power initial power the horizontal louver may generate a sound for 10 seconds this is a normal operation 5 Wow THE nin COMDITIONER WORKS AUTOMATIC OPERATION ECONOMIC SLEEP operation e When you set the air conditioner in AUTO mode it will E automatically select cooling heating cooling heating iz models only or fan only operation depending on what Set PE temperature you have selected and the room temperature The air conditioner will control room temperature rT automatically round the temperature point set by you Cooling e f the AUTO mode is uncomfortable you can select desired conditions manually ECONOMIC SLEEP operation ECONOMIC SLEEP OPERATION When you push ECONO SLEEP button on remote controller during cooling heating cooling only type without or AUTO operation the air conditioner will automatically increase cooling or decrease heating 1 C per hour The set temperature will be steady 2 hours later The fan Thogr nout speed will be automatically controlled This feature can maintain the m
6. Kcimaire OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner CONTENTS SAFETY PRECAUTIONS iicissinnscucsiterecaniasaariaesasisusidanatenianasnsetdiuvewasnadsintedhinweciananasadecadey PARIS NAMES ict eviussccwtnceistiiensiemtndapediexnuated sGnsindcecenintalenmnisecntivinnialenenadeutinaunatanuntn OPERATING TEMPERATURE ncsisnasscssccnstecncanacatecaannatcascamsesasnnnnatcadennaneabacanadeantans MANUAL OPERATION cciicaseccinteicnsinianciasataibiwa inate da darsiiesisdiiedaiinoncicasitinunisiiiiindadatndcunnuilie ADJUSTING AIR FLOW DIRECTION cccccccceseseseeeeeeeesesseeeeeeeeessseeeeseseeesseeeeees HOW THE AIR CONDITIONER WORK Sic csiccicicncasscccssenctcccsetssessdasseecucusesannennnenie OPTIMAL OPERAT ION a siiscsictieneciccansamsicadentasuaniattunsiens cduuneeusansnunetosncudiauduaustecaynudesbaawe AIT ENA NCE isacccta soda tennsinncaanndveniinansesnauswiesioadindnacesneiealeausindkanteiiardaneamiu OPERATION TIPS sarsarcsas asistencia adeeb la aislacdammasdues ded nud ewes demeeeutdndatumusanciensila TROUBLESHOOTING TP Sietntedencscsdrtsdicintcinntedueanciisanst eur cern deite aba neaibantwudiniaeauuien Read This Manual Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you
7. a great deal of time and money over the life of your air conditioner You ll find many answers to common problems in the chart of troubleshooting tips If you review the chart of Troubleshooting Tips first you may not need to call for service N CAUTION e Contact an authorised service technician for repair or maintenance of this unit e Contact the installer for installation of this unit e The air conditioner is not intended for use by young children or invalids without supervision e Young children should be supervised to ensure that they do not play with the air conditioner f the power cord is to be replaced replacement work shall be performed by authorised personnel only Installation work must be performed in accordance with the national wiring standards by authorised personnel only Safety Precautions To prevent injury to the user or other people and property damage the following instructions must be followed Incorrect operation due to ignoring of instructions may cause harm or damage The seriousness is classified by the following indications J N WARNING This symbol indicates the possibility of death or serious injury N CAUTION This symbol indicates the possibility of injury or damage to property E Meanings of symbols used in this manual are as shown below D Never do this L D Always do this J A WARNING O Connect with the power Do not operate or stop
8. emperature sensor Display panel Infrared signal receiver Remote controller Drain hose refrigera nt connecting pipe Connective cable Stop valve DISPLAY PANEL OPERATION indicator The indicator flashes once every second after power is on and illuminates when the air conditioner is in operation TIMER indicator The indicator illuminates when TIMER is set ON PRE DEF Indicator For cooling amp heating model only This indicator illuminates when the air conditioner starts defrosting automatically or when the Anti cold air function is activated in heating operation AUTO indicator This indicator flashes when the air conditioner is in AUTO operation ECON indicator This indicator illuminates while the air conditioner is in economic operation Note All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased The actual shape shall prevail OPERATING TEMPERATURE Temperature Mode Cooling operation Heating operation Drying operation Room temperature 17 C 32C vers 0C 17 C 37 C 18 C 43C C4 FC 5 C 43C For the models with r 3 Outdoor temperature low temperature cooling system 7 C 24C 21 C 57C 21 C 52 C For special tropical For special tropical models models CAUTION 1 If air conditioner is used outside of the above conditions certain safety protection feat
9. ess when the air conditioner restarts in HEAT mode operation after defrosting 3 Low noise of the air conditioner e You may hear a low hissing sound when the compressor is running or has just stopped running This sound is the sound of the refrigerant flowing or coming to a stop e You can also hear a low squeak sound when the compressor is running or has just stopped running This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing e Anoise may be heard due to louver restoring to its original position when power is first turned on 4 Dust is blown out from the indoor unit This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit 5 A peculiar smell comes out from the indoor unit This is caused by the indoor unit giving off smells permeated from building material from furniture or smoke 6 The air conditioner turns to FAN only mode from COOL or HEAT For cooling and heating models only mode When indoor temperature reaches the temperature setting on air conditioner the compressor will stop automatically and the air conditioner turns to FAN only mode The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode For cooling and heating models only to the set point 7 Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humid
10. explosion or fire shock OVentilate room before operating air Do not disassemble or modify unit conditioner if there is a gas leakage from another appliance e It may cause explosion fire and burns e t may cause failure and electric shock A CAUTION When the air filter is to be Do not clean the air Ventilate the room well when removed do not touch the conditioner with water used together with a stove metal parts of the unit etc e t may cause an injury e Water may enter the unitand An oxygen shortage may occur degrade the insulation It may Do not use for special purposes cause an electric shock e Do not clean unit when e This could injure the pet or e Do not use this air conditioner to power is on as it may cause plant Pe verte naar objects food fire and electric shock it may ft may cause deterioration of cause an injury quality etc When the unit is to be Do not put a pet or house cleaned switch off and turn plant where it will be off the circuit breaker exposed to direct air flow Stop operation and close Do not place obstacles Turn off the main power the window in storm or around air inlets or inside switch when not using the hurricane of air outlet unit for a long time e Operation with windows e It may cause failure of e It may cause failure of product opened may cause wetting appliance or accident or fire of indoor
11. ity relative humidity higher than 80 Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed 8 Heating mode For cooling and heating models only The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation When the outdoor temperature falls heat drawn in by the air conditioner decreases accordingly At the same time heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature If a comfortable temperature can t be achieved by the air conditioner we suggest you use a supplementary heating device 9 Auto restart function Power failure during operation will stop the unit completely For the unit without Auto restart feature when the power restores the OPERATION indicator on the indoor unit starts flashing To restart the operation push the ON OFF button on the remote controller For the unit with Auto restart feature when the power restores the unit restarts automatically with all the previous settings preserved by the memory function 10 Lightning or a car wireless telephone operating nearby may cause the unit to malfunction Disconnect the unit with power and then re connect the unit with power again Push the ON OFF button on the remote controller to restart operation 10 Troubleshooting tips Malfunctions and Solutions Stop the air conditioner immediately if one of the follo
12. k When cleaning the unit first make sure that the power and circuit breaker are turned off OPERATION TIPS The following events may occur during normal operation 1 Protection of the air conditioner Compressor protection e The compressor can t restart for 3 minutes after it stops Anti cold air Cooling and heating models only e The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the following three situations and the set temperature has not been reached A When heating has just starting B Defrosting C Low temperature heating e The indoor or outdoor fan stop running when defrosting Cooling and heating models only Defrosting Cooling and heating models only e Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner e During this condition air conditioner will stop heating operation and start defrosting automatically The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost buildup on the outdoor unit 2 Awhite mist coming out from the indoor unit e Awhite mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity e A white mist may generate due to moisture generated from defrosting proc
13. ost comfortable temperature and save more energy for you Temperature Heating DRYING OPERATION The dry mode will automatically select the drying operation based on the difference between the set Room K temperature and the actual room temperature ee gt Time The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only The fan speed indicator will display AUTO and low speed will be used Cooling Fanonly Cooling Fanonly Cooling a set temperature DRYING operation OPTIMAL OPERATION To achieve optimal performance please note the following e Adjust the air flow direction correctly so that it is not directed on people e Adjust the temperature to achieve the highest comfort level Do not adjust the unit to excessive temperature levels e Close doors and windows on COOL or HEAT modes or performance may be reduced e Use TIMER ON button on the remote controller to select a time you want to start your air conditioner e Do not put any object near air inlet or air outlet as the efficiency of the air conditioner may be reduced and the air conditioner may stop running e Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position Household Drain Cleaner
14. the Do not damage or use an properly unit by switching on or off unspecified power cord q the power Otherwise it may cause electric It may cause electric shock or fire It may cause electric shock or fire shock or fire due to excess heat due to heat generation generation Do not modify power cord Do not operate with wet Do not direct airflow at length or share the outlet hands or in damp room occupants only with other appliances environment It may cause electric shock or It may cause electric shock This could damage your health fire due to heat generation Always ensure effective Do not allow water to run Always install circuit earthing into electric parts breaker and a dedicated power circuit No earthing may cause electric It may cause failure of machine No installation may cause fire shock or electric shock and electric shock Disconnect the power if O Do not drink water drained Do not open the unit strange sounds smell or from air conditioner during operation smoke comes from it t may cause fire and electric It contains contaminants and It may cause electric shock shock could make you sick Keep firearms away Do not use the power cord Do not use the power cord near close to heating appliances flammable gas or combustibles such as gasoline benzene thinner etc t may cause fire t may cause fire and electric t may cause an
15. tivated Wait If the trouble has not been corrected please contact a local dealer or the nearest customer service center Be sure to inform them of the detailed malfunctions and unit model Notes Do not attempt to repair the unit yourself Always consult an authorised service provider 11
16. ures may come into operation and cause the unit to function abnormally 2 Room relative humidity less than 80 If the air conditioner operates in excess of this figure the surface of the air conditioner may attract condensation Please sets the vertical air flow louver to its maximum angle vertically to the floor and set HIGH fan mode 3 Optimum performance will be achieved within these operating temperature MANUAL OPERATION Manul operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted Open and lift the front panel up to an angle until it remains fixed with a clicking sound Push the button until the AUTO indicator is lit the unit will work in forced AUTO mode the AUTO COOL o Manual default setting temperature is 24 C control button z Close the panel firmly to its original position CAUTION Once you push the manual button the operation mode is shifted in an order as AUTO COOL OFF e Push the manual button until the OPERATION Manual AUTO COOL o indicator flashes rapidly five times per second Control bukon the unit now is operating in forced COOL For lt 16000Btu h Models mode This is used for testing purposes only e When the OPERATION indicator goes off the air conditioner is OFF e To restore the remote controller operation use the Manual remote controller directly O COOL control button Z auTO
17. uver or to damage vertical louvers When the air conditioner is in operation and the horizontal louver is in a specific position move the lever at left or right depending on model end of the air outlet to the desired position To automatically swing the air flow direction up down Perform this function while the air conditioner is in operation Press the SWING button on the remote controller To stop the function press the SWING button again e Press AIR DIRECTION button to lock louver in desired position A CAUTION The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation including when the TIMER ON is set Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dry mode Otherwise condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings Do not move the horizontal louver manually Always use the AIR DIRECTION or SWING button If you move this louver manually it may malfunction during operation If the louver malfunctions stop the air conditioner once and restart it e When the air conditioner is started immediately after it was stopped the horizontal louver might not move for approximately 10 seconds Open angle of the horizontal louver should not be set too small as COOLING or HEATING performance may be impaired due to too restricted air flow area e Do not
18. wing faults occur Disconnect the power and contact the nearest customer service center Trouble OPERATION indicator or other indicators flash rapidly 5 times every second and this flash can t be fixed by disconnecting the power and then connect it in again Fuse blows frequently or circuit breaker trips frequently Other objects or water penetrate the air conditioner The remote controller won t work or works abnormally Other abnormal situations Malfunctions Cause What should be done Unit does not start Unit not cooling or heating Cooling heating models only room very well while air flowing out from the air conditioner Power cut Wait for power to be restored Unit may have become unplugged Check that plug is securely in wall receptacle Fuse may have blown Replace the fuse Battery in Remote controller may have been exhausted Replace the battery The time you have set with timer is incorrect Inappropriate temperature setting Wait or cancel timer setting Set temperature correctly For detailed method please refer to Using remote control section Air filter is blocked Clean the air filter Doors or Windows are open Close the doors or windows Air inlet or outlet of indoor or outdoor unit has been blocked Clear obstructions away first then restart the unit Compressor 3 minutes protection has been ac