         Contents
1.  Setup in MPA Mode    2 3 2  Operating the BLAM in MPA Mode with External Refill    If your experiment requires running the BLAM at high output for long periods of time it  is recommended that the device be operated with the external refill option  This allows  the user to refill the BLAM with the test liquid without interrupting atomization    Follow these steps to run the BLAM in MPA mode with external refill option     1  Remove the liquid feed port plug on the lid    10     11     12        Install the provided liquid feed barb and tighten it up      If you will use a syringe pump for the refill  fill the syringe with about 100 ml of    test article and place it in the pump    If you are using a low flow peristaltic pump instead  fill a glass beaker with about  100 ml of liquid and dip the inlet end of the pump s tube in it    Using a piece of thin silicon tube  connect the outlet of a syringe or low flow  peristaltic pump to the BLAM s liquid feed port  refer to Figure 3      Next  follow steps 1 through 7 in Section 2 3 1 to operate the atomizer  When the liquid in the jar is almost exhausted  turn on the external refill pump   When the jar 1s refilled with the predetermined amount of liquid  turn the pump    off     ATTENTION  Make sure that all the connections between the external     refill pump and      BLAM        air tight     Repeat the refill procedure as often as needed during the atomization process    Shut down compressed air supply to the atomizer when you a
2.  occlusion from solids that may dry inside the nozzle and or the nozzle  is free from any residuals that may cause cross contamination  To do this  after  cleaning the parts externally  feel the jar with few milliliters of water and run the  BLAM for a few minutes in MPA mode  As clean water 1s atomized  it washes the  cavities inside the nozzle and the jet holes     WARNING  Whether you are using the BLAM in SPA or MPA mode      always replace the internal liquid aspiration feeding tube during the  cleaning decontamination process when you switch from one test article  to another to avoid potential cross contamination     Autoclaving can be used to decontaminate the BLAM parts if the device is used with  pathogenic test articles  If you opt for autoclaving  you should first contact CH  Technologies in order to establish appropriate guidelines for cleaning under high  temperature and pressure     is not carried out properly  it may cause mechanical damage and or      WARNING  If autoclaving or decontamination with corrosive chemicals  chemical corrosion to various BLAM parts     The O ring in the BLAM   s lid should be inspected during each cleaning  The slightest  tear or cut on the O ring will result in an inappropriate sealing of the device and may  result in leaking of the test article into the air  The O ring should be changed at  frequent intervals because it may deteriorate with time     2 5  Nozzle Maintenance and Adjustment    To make sure that the BLAM performs cons
3. Blaustein Atomizer  BLAM   Multi jet Model       CH TECHNOLOGIES  USA     CONTENTS    1  General Description and Specifications    oven e cece nnn eeen eenen 3  ET  MAURO CIC tio Bono masas                                                               3  12 SPECI CAUONS ts             nae 4  1 3  Mechanism      ODS TON    usse te comis                     RR RD PED EN I DES 4   2 BLAM                                  6  Dal Packs the BLAM zen ee       6           Tesuns m 6  2 9  BLAM Operation Procedures              ES epe mda ue ex eat URS er bl 7   2 3 1  Operating      BLAM in MPA Mode    eenen 7   2 3 2  Operating the BLAM in MPA Mode with External Refill                  8   2 3 3  Operating the BLAM in SPA                                                     10  2 4  Cleaning Decontamination Procedures  ane eeens  11  2 5  Nozzle Maintenance and                                          eneen 12   GED TT Douce nodis mere ne            see ee 14      NISL                          are 15   Appendix 1  Overview of Multi jet BLAM Assembly in MPA Mode                  16   Appendix 2  Overview of Multi jet BLAM Assembly in SPA Mode                   17   Appendix 3  BLAM Exploded Das am aan ae a                   YR EE 18   Appendix 4  View of Multi jet BLAM               esses 19    Appendix 5  View of the Complete Multi Jet BLAM Kat    20    1  GENERAL DESCRIPTION AND SPECIFICATIONS    1 1  Introduction    The Blaustein Atomizer  BLAM  is a high output atomizer that uses t
4. ane tubing or one that that can withstand the pressure used   BLAM  s air inlet is equipped with a 1   4    push to connect fitting so the air line can  be connected by simply pushing the tubing in  If you BLAM comes with non   standard fittings  use appropriate couplers to connect the air line to the atomizer   If you are not using any of CH Technologies system control units  make sure that  the compressed air line 1s equipped with appropriate pressure and flow  controllers  An illustration of a standard setup of the BLAM in MPA mode is  given in Figure 2     5  Connect the BLAM outlet to your system or application using appropriate fittings   Make allowance for dilution of the aerosol outflow 1f desired     6  Start atomization by turning on air    7  Using your flow controller  adjust the air flow at about 2 L min per jet   8 L min  for the 4 jet BLAM   16 L min for the 8 jet BLAM   If you need more output   increase first the upstream pressure of the compressed air line and then increase  air flow rate to the atomizer        ATTENTION  DO NOT exceed 90 psi upstream pressure     8  Turn off atomization at any time by shutting down compressed air supply to the  atomizer    9  Remove the compressed air line from the BLAM   s air inlet  10  Take the atomizer for cleaning decontamination  Aerosol    VALVE PRESSURE  T REGULATOR           FLOWMETER                 Compressed Air               Pd            PRESSURE  GAUGE    GE BLAM  x ATOMIZER    Figure 2  Schematic of BLAM   s
5. ble it into the lid   Make sure that the assembly is air tight     ATTENTION  DO NOT fill the jar excessively  The solution in it serves  only the purpose of a soft impaction surface for the aerosol and it will not  be used for atomization       If you will use a syringe pump for feeding the BLAM  fill the syringe with the    predetermined amount of test article and place it in the pump  Use a syringe large  enough so that the BLAM does not run out of liquid before the atomization  session IS up       If you are using a low flow peristaltic pump instead  fill a glass beaker or another    appropriate container with the predetermined amount of liquid and dip the inlet  end of the pump   s tube in it  If your test article is a solution containing pathogens   make sure that the container is properly sealed  with a ventilation hole on the lid        Using a piece of thin silicon tube  connect the outlet of the syringe or low flow    peristaltic pump to the BLAM   s liquid feed port          10    ATTENTION  Make sure that all the connections between the  liquid feed pump and the BLAM are air tight     10  Turn ON the liquid feed pump and adjust the feed rate as desired    11  When the liquid reaches the liquid feed port of the BLAM  turn ON compressed  air supply to the device     12  Next  follow steps   through 7 in Section 2 3 1 to operate the atomizer    13  When the atomization process 15 up  turn OFF the liquid feed pump and  in quick  sequence shut down compressed air suppl
6. d or autoclaved     13    3  DISCLAIMER   The BLAM Atomizer is subject to all the terms of CH Technologies  USA  standard  limited warranty  The BLAM 1s a specialized article of research equipment intended for  use by trained professionals  No liability is accepted by CH Technologies  USA  on  account of misuse  misapplication or mishandling  CH Technologies  USA  specifically  does not condone nor endorse any application or use which involves restricting emissions  from the device and thus causing pressurizing of the jar  Further  CH Technologies   USA  accepts no liability for exposure to toxic  infectious or harmful substances  resulting from the use of this apparatus     14    4  LIMITED WARRANTY    CH Technologies  USA  warrants equipment of its manufacture to be free from defects in  workmanship and material  We make no warranty  express or implied  except as set forth  herein    CH Technologies  USA    s liability under this warranty extends for a period of one  1   year from the date of shipment  It is expressly limited to repairing or replacing at the  factory during this period and at CH Technologies  USA    s option  any device or part  which shall within one year of delivery to the original purchaser  be returned to the  factory  transportation prepaid and which on examination shall in fact be proved  defecting  CH Technologies  USA  assumes no liability for consequential damages of  any kind  The purchaser  by acceptance of this equipment  shall assume all liabil
7. e The BLAM assembly as seen in Appendix 1 or 2    e Package of accessories containing     2 spare 10 32 barb fittings    2 spare 10 32 plugs    2 spare O ring sets    Spare silicon tubing for liquid feed    Allen wrench for the nozzle screws    e Carrying Case    Your BLAM may vary slightly in appearance depending upon the specific model that you  ordered  4 jet vs  8 jet   type of discharge  vertical vs  horizontal  and fittings you  requested  Appendix 4 shows photographs of multi jet BLAMs with vertical and  horizontal discharge  An overview of parts and accessories of the BLAM   s complete kit  is given in Appendix 5    Any changes from the standard pieces listed above will be noted on your shipping memo   PLEASE KEEP YOUR SHIPPING MEMO FOR FUTURE REFERENCE  If you find  that anything has been damaged in transit  contact the carrier of the shipment  immediately in addition to CH Technologies     2 2  Initial Testing    After unpacking  you should immediately check the operation of the device  Your BLAM  comes fully assembled so it ready to be used for a performance check  Follow the steps  outlined in Section 2 3 1  to set up and operate the device  Use ONLY distilled water for  initial testing     When the air source is turned on  mist should appear at the aerosol outlet as shown in  Figure 2  If mist does not appear  recheck all your fittings and make sure that jar is  screwed in tight  The operation of the BLAM depends upon it being a completely sealed  unit     Perfor
8. he jet nebulization  principle of the Collison Nebulizer  which has long been the recognized as the technique  for the efficient aerosolization of various liquids  However  the BLAM relies on a new   patent pending design  which allows for a more efficient generation of aerosol than the  Collison or other existing devices  in both its single pass and recirculating configurations   This innovative design allows users to produce liquid aerosol at high particle  concentrations and very narrow particle size distribution     The BLAM is superbly suited to handle various liquid media  such as water based drug  solutions  solvent based mixtures such as pesticides  oils and other viscous liquid  suspensions and biological test articles such as bacterial viral suspensions  The multi jet  BLAM 1s able to efficiently aerosolize and deliver high aerosol outputs of viscous liquid  media  which is particularly of great importance in meeting the OECD requirements for  pesticide testing  Also  it provides bioaerosols with enhanced viability of pathogenic  microorganisms for aerobiology research     The particle size distribution of the aerosolized mist will depend on the nature of the  liquid test article  However  for most solutions and suspensions  the BLAM will deliver a  narrowly distributed mist that falls well within the respirable cutoff     The multi jet BLAM can be used in Single Pass Atomization  SPA  mode  with the liquid  feed being injected externally by a metering device  or Mu
9. istently over long periods of time  the nozzle  should be serviced periodically  The frequency of the service will depend on the usage  intensity and type of test articles utilized  The maintenance procedure of the nozzle is the  following     1  Remove the nozzle from the air stem using appropriate wrenches    12      Remove the barb and plug fittings from the liquid feed aspiration ports      Use the provided allen wrench to remove the four screws that hold together the    nozzle plates    Split the plates and lay them down on a clean work surface      Remove and carefully inspect the O rings that seal the plates against each other     refer to Figure 1 for details   If they show signs of damage  replace them with O   rings from the spare set supplied with the BLAM       Visually inspect the jet holes against a light source and observe if there is any    visible occlusion present in any of them  If any of the jets is clogged  place the jet  plate in an ultrasonic bath with distilled water for about 30 minutes       Wash the plates with a mild soap solutions and rinse them well with tap or    distilled water      After the plates have dried  place the O rings on the plates and reassemble the  nozzle      Apply some Teflon tape on the threads of the air stem and thread the nozzle using    appropriate wrenches    any servicing of the nozzle should take place after the device has been      WARNING  If the BLAM has been used with pathogenic test articles   properly decontaminate
10. ity for  consequences of its misuse by the purchaser  his employees or others  This warranty will  be void if the equipment is not handled  installed  or operated in accordance with our  instructions  If damage occurs during transportation to the purchaser  CH Technologies   USA  must be notified immediately upon arrival of the equipment     A defective part in the meaning of this warranty shall not  when such part is capable of  being repaired or replaced  constitute a reason for considering the complete equipment  defective  Acknowledgment and approval must be received from CH Technologies     USA  prior to returning parts or equipment for credit     No representative of ours has authority to change or modify this warranty in any respect     15    Appendix 1  Overview of Multi jet BLAM Assembly in MPA Mode    Jaeger Joint          Air Inlet    Fitting N  Outlet  Air Stem X      Compression Nut N    Plug     N O ring  Lid us    Plug           Atomization  Nozzle  Liquid Aspiration  Tube  Precious  Fluid Well    16    Appendix 2  Overview of Multi jet BLAM Assembly in SPA Mode    Jaeger Joint          Air Inlet    Fitting CX    Outlet  Air Stem N 1   Compression Nut  Liquid Feed N f  Port    O ring       Liquid Feed  Tube  Polycarbonate  Jar  Atomization  Nozzle  Precious  Fluid Well  Plug    17    Appendix 3  BLAM Exploded Diagram       gu Air Inlet Fitting  p i Air Stem               m  Compression Nut  ais Be ER Ferrules       Lid With Aerosol Outlet       HB Liquid Feed B
11. liquid feed port located on the Body     The aerosol generated by the atomization process is sprayed downwards and  after  impacting the surface of the liquid inside the jar  it makes a 180   turn and it 15 forced up  the outlet tube on top of the BLAM lid  During this process  larger droplets are collected  on the liquid surface due to impaction as they cannot make the U turn  The end result 1s a  very fine mist  well within the respirable range and with narrow size distribution     The properties of the aerosol generated by the multi jet BLAM are a function of the jet  hole size and expansion cone size  The BLAM jets are equipped with 0 010  diameter  laser cut rubies which guarantee long lasting precision in the atomization process  For  specific applications  the BLAM can be fitted with other non standard jet hole sizes and  expansion plates     The multi jet BLAM is equipped with a precious fluids jar which has a small well at the  bottom  In MPA mode  the thin silicone tube attached to the liquid aspiration port on the  Expansion Plate extends all the way to the bottom of the well  This allows the atomizer to  essentially use every last drop of the test fluid  See Appendices 1 and 2 for an overview  of parts of an assembled multi jet BLAM in both SPA and MPA mode     2  BLAM OPERATION    2 1  Unpacking the BLAM    When you receive your BLAM  you should unpack it carefully and check to make certain  that the following parts are all present and in undamaged condition     
12. lti Pass Atomization  MPA   mode where the atomizer jar is pre filled with the liquid test article and the medium is  cyclically re circulated  atomized  to the four or eight sonic velocity air jets until is  exhausted     The BLAM as a retrofit can be exchanged for existing Collison type nebulizing nozzles  and used as an atomizer by simply mounting it in a suitable inhalation exposure system  using standard tube and pipe fittings  The retrofit kit is packaged as a direct nozzle  replacement for many USA Collison nebulizers     The BLAM is equipped with a vapor polished polycarbonate jar that is highly resistant to  heat and mechanical stress  but at the same time allows a clear visual of the atomization  process inside the device  As all other CH Technologies nebulizers  the BLAM outlet 15  equipped with a vertical or horizontal Jaeger joint connector that is the standard  connector of our inhalation systems  Other custom designed connectors are available  upon request     The complete CHT BLAM is best used as an atomizer that interfaces directly to CH  Technologies systems and equipment but with suitable modifications also adapts to other  non CHT equipment    1 2  Specifications    Particle diameter  Approximately 0 7 2 5 um   Models available  4  and 8 jet   Air flow rate  4 30 L min   Liquid Feed Rate  0 1     60 ml min   Discharge  Vertical or Horizontal   Material  Stainless Steel 316  stem  amp  plates  and Ploycarbonate  jar  amp  head     1 3  Mechanism of Operatio
13. m a visual inspection of the jet operation and make sure that none of them appears  to be aerosolizing less than others or not at all  All the jets are identical and should  perform exactly the same     2 3  BLAM Operation Procedures    2 3 1  Operating the BLAM in MPA Mode    Your BLAM comes set up for MPA mode operation  In this mode  the liquid feed hole on  the lid as well as liquid feed port on the nozzle body are plugged  A barb fitting with a  short piece of silicon tube is assembled into the liquid aspiration port on the jet plate  See  Appendix 1 for a representation of the BLAM in MPA mode     Follow these steps to operate the BLAM in MPA mode     1  Remove the jar and fill it with about 100 ml of the test solution or suspension     device is operated at high outputs and or for long aerosolization sessions     ATTENTION  The amount of liquid can alternatively be greater  if the  or smaller  af you are using precious fluids     2  Reassemble the jar into the lid and make sure that it   s tight    3  Release the compression nut that holds the air stem and adjust the height of the  nozzle at about 1  from the surface of the liquid  Make sure that liquid aspiration  tube connected to the nozzle is long enough to reach to the bottom of the precious  fluid well  Tighten the nut when you are done        ATTENTION       NOT use tools to tighten the air stem compression  nut     4  Using a 4  OD tube  connect a compressed air line to the air inlet of the BLAM   Use polyureth
14. n    Knowledge of the mechanism of aerosol formation by the BLAM will help you in  determining the aerosol characteristics as well as being useful for maintenance  The  atomizing head at the end of the air supply stem is the key to aerosol formation  It is  composed of three main parts  Nozzle Body  Jet Plate and Expansion Plate  Figure 1      Compressed Air           Nozzle Body        Liquid Channel    Liquid Feed Port N       Air Channel       O ring  Assembly Screw N x Jet Plate       Jet Hole Jet Ruby  Expansion Cone Liquid Cavity    Liquid Suction Port Expansion Plate    Figure 1  Components of BLAM    s Atomizing Nozzle    The atomization occurs when the pressurized air coming from the stem pushes through  the jets on the Jet Plate at sonic velocity  The jets are very small orifices through which  pressurized air flows at a constant velocity  This process creates a powerful vacuum  effect in the cavity  only 0 002    deep  between the Jet Plate and Expansion Plate which  drives the liquid from the liquid chamber to the jets  The liquid then reaches the wells  around the jets where is aspirated in and sheared into tiny droplets as the air expands after    4    the jet  In multi pass mode  the liquid is driven into the liquid chamber through the  suction tube at the center of the Expansion Plate simply by the vacuum created by the air  Jets  On the other hand  in single pass mode the suction port on the Expansion Plate is  plugged and the liquid is pumped in through the 
15. re done with the  atomization process    Remove the refill tube from the liquid feed port on the lid  Remove the compressed air line from the BLAM   s air inlet    Disconnect the atomizer from the external refill pump and take it for  cleaning decontamination    Aerosol    VALVE PRESSURE      REGULATOR         FLOWMETER  r  r Compressed    Air  Liquid Feed  o p               ER A    PRESSURE  GAUGE    BLAM  ATOMIZER    Figure 3  Schematic of BLAM   s Setup in MPA Mode with External Refill    2 3 3  Operating the BLAM in SPA Mode    When you are using your BLAM with live pathogen suspensions  it is recommended that  the device be operated in SPA mode  In this mode  the test article passes only once  through the atomization process which results in preservation at a large extent of the  viability of the microorganisms in the aerosol  The SPA mode is also recommended for  proteinic solutions because prevents foaming during atomization     Follow these steps to convert the BLAM and run it in SPA mode     1     2     Remove the BLAM jar  Remove the liquid feed port plug on the lid  Install the provided liquid feed barb instead of it and tighten it up    Switch places of the liquid aspiration port barb fitting  center of the jet plate  with  the liquid feed port plug  on the nozzle body     Using a piece of the supplied silicon tube  connect the liquid feed port on the lid  with the liquid feed port on the nozzle body    Fill the jar with about 20 30 ml of test solution and reassem
16. ulkhead      Wes  Lis Feed Barb  mier         BLAM Nozzle Body       BLAM Expansion Plate                  Oring  Shoulder Bolt x4  iib o      Polycarbonate Precious Fluids Jar       18    Appendix 4  View of Multi jet BLAM       Vertical Discharge BLAM    Horizontal Discharge BLAM    19    Appendix 5  View of the Complete Multi Jet BLAM Kit    O ring Set O ring Set    E a  OO OO  MM Barbs    Silicon Tube    Spare Plugs       Allen Key            w                    4     Complete BLAM Assembly    20    
17. y to the atomizer    14  Remove the liquid feed tube from the liquid feed port on the lid  15  Remove the compressed air line from the BLAM   s air inlet    16  Take the atomizer for cleaning decontamination    Aerosol  VALVE PRESSURE  REGULATOR    FLOWMETER    Air  plc v  DE     Frauen       Liquid Feed     _                         PRESSURE  GAUGE    SYRINGE  PUMP    HE er en    BLAM  ATOMIZER    Figure 4  Schematic of BLAM   s Setup in SPA Mode    2 4  Cleaning Decontaminating Procedures    Your BLAM should perform indefinitely if it 15 cleaned and maintained properly  The  device should be cleaned after each use     11    If you are using your BLAM with any aqueous solutions that contain no pathogens   cleaning with a mild soap solution in warm water is generally adequate  Depending  on the test article used  special solvents may be used in certain cases  Be sure that the  O rings are compatible with any solvents used  Special chemical resistant O rings are  available from CH Technologies if needed  Distilled water is a good choice for the  final rinse  warm tap water may work also  You must judge the success of your  cleaning rinsing with your own QA QC wipe tests or similar assessments  The  cleaned BLAM parts should be allowed to air dry or they may be dried with warm  forced air     If your tests involve atomization of viscous suspensions or you are switching from  one test article to another  an additional step is needed to make sure that the jets are  freed from any
    