1. cs Route power wires in a safe manner in accordance with good practice and local codes Wear proper personal protective equipment including safety glasses and insulated gloves when making Paaa Aa to Sones circuits Ensure hands shoes and floor are dry before making any connection to a power line Make sure the unit is turned OFF before making connection to terminals Make sure all circuits are de energized before making connections Before each use inspect all cables for breaks or cracks in the insulation Replace immediately if defective 6 Technical Support No part of this publication may be reproduced without the prior agreement and written permission of For assistance and manual updates contact Technical Support at the Horner APG Inc Information in this document is subject to change without notice following locations North America Europe Tel 317 916 4274 Tel 353 21 4321266 Fax 317 639 4279 Fax 353 21 4321826 Web _http www heapg com Web _ http www horner apg com Email techsppt heapg com Email tech support horner apg com 3 2 2010 Page 4 of 4 1037
2. _ In Out_ 3 SHLD Shield Ground 4 CNH CANDataHigh I MOut OO NC NoConnect WARNING Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards WARNING In the event of repeated failure do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse WARNING EXPLOSION HAZARD Substitution of components may impair suitability for Class l Division 2 AVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE COMPOSANTS PEUT hii ENErnEE Por RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1 DIVISION 2 Speeds 10 BaseT Ethernet 10 Mbps 100 BaseTx Fast Ethernet 100 Mbps Half or Full Duplex Auto Negotiation Both 10 100 Mbps and Half Full Duplex Shielded RJ 45 A i CATS or better UTP Auto MDI MDI X WARNING The USB parts are for operational maintenance only Do not leave permanently connected unless area is known to be non hazardous WARNING EXPLOSION HAZARD BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON HAZARDOUS AVERTISSEMENT RISQUE D EXPLOSION AFIN D EVITER TOUT RISQUE D EXPLOSION S ASSURER QUE L EMPLACEMENT EST DESIGNE NON DANGEREUX AVANT DE CHANGER LA BATTERIE WARNING Battery May Explode If Mistreated Do Not Recharge Disassemble or Dispose Of In Fire Power Port and Wiring WARNING Only qualified electrical personnel familiar with the constr
3. for Cscape programming and Application Defined Communications Serial Comm Ethernet Used for Cscape MJ1 programming and Application MJ2 Defined Communications Pa USBB For network i J gt communication and L 25 al programming of OCS CAN Comm Ethernet XL6e only USB USB A Port 3 2 2010 Page 2 of 4 1037 MANO884 04 EN Specifications Installation Serial Communications MJ2 Pinouts in Half and Full Duplex Modes MJ1 RS 232 RS 485 Use for Cscape programming and Application Defined Communications MJ2 RS 232 RS 485 Use for Application Defined Communications IN G Soma TX OUT TX RX IN OUT TX RX IN OUT 15V 60MA Max T IN TX oos n 1 MJ2 Half Duplex Mode RX TX IN OUT RX RX TX IN OUT RX Signal Direction Table Ports and Functions Functions Port 1 MJ1 Port 2 MJ2 RS 232 Hardware Handshaking Ladder function controlled 5V 60mA Max PX ae v y v y v Serial Downloable Protocols RS 485 Full duplex RS 485 Half duplex Y MJ2 Full Duplex Mode External DIP Switch Settings As seen when looking at the side of the XL6 unit H SW1 ON enables MJ2 RS485 port termination 121 Ohms The DIP Switches are used for termination of the FS 485 ports The i OFF disables MJ2 RS485 port termination XL6 is shipped un terminated ll cai as SW2 amp SW3 ON places MJ2 RS485 port in half duplex mode OFF places MJ2 RS485 po
4. Cs flash device connectivity and programming Port Removable Removable Media for upto 2 GB of storage for programs Media data logging or screen capture Remote IO modules communicating on CAN 2 Installation 1 Prior to mounting observe requirements for the panel layout design and spacing clearances in the OCS XL6 Series Manual MAN0883 2 Cut the host panel 3 Insert the OCS through the panel cutout from the front The gasket material needs to be between the host panel and the OCS Caution Do not force the OCS into the panel cutout An incorrectly sized panel cutout can damage the touch screen 4 Install and tighten the mounting clips provided with the OCS until the gasket material forms a tight seal 001XLQX007 5 Connect cables as needed such as communications programming power D and CsCAN cables to the ports using the provided connectors 6 Begin configuration procedures Mounting clips 3 2 2010 Page 1 of 4 1037 MANO0884 04 EN Specifications Installation 4 Ports and Connectors Removable Media Memory Slot USB Mini B USB 5 pin programming port User Interface Ethernet XL6e only USB USB A Port Micro SD Memory Slot Uses Removable Memory for data logging screen captures program loading and recipes Horner Part No HE MC1 USBA For flash drive connectivity Serial Communications MJ1 MJ2 RS 232 RS 485 Used
5. MANO0884 04 EN Specifications Installation e XL6 XL6M XL6e OCS Models HE XL100 HE XL1M0 HEXT350C100 HEXT280C100 HORNER HE XL1E0 HEXT351C100 1 Specifications 3 Panel Cut Out and Dimensions EENI o 2 ak x UE Note Max panel thickness 5 mm Required Refer to the User Manual MAN0883 for panel box information and a checklist of requirements Power 500 mA 24 VDC for p q Steady state jr 30 A for 1 ms 24 VDC DC Switched Note The tolerance to meet NEMA standards is 0 005 0 1 mm 2 5 A for 4 ms 24 VDC AC Switched Inrush Primary Power 10 30 VDC Range fais 5 to 95 Non condensing R 125 3 mm TYP 7 5 150 RADIUS CORNERS 35 ppm maximum at 25 C 131mm WHEN REQUIRING Accuracy 1 53 Minutes per Month DUST OR WATER Operating R o TIGHT SEAL PER Dispiay 5 7 QVGA TFT Type Display Screen 320 x 240 Dimension 0010CS003 R1 Display 2 75 MB Memory Display Life Minimum 40000 hours 50 brightness 25 deg C 5 user defined Function keys and a System Key Screens 1023 supported Colors 32768 16 shade Grey scale XL6M models only Weight 26 5 oz 751 kg fil T CE _ USA http www heapg com Pages TechSupport ProductCert ht ml Europe http www horner apg com en support certification aspx Serial Ports ce UL Connectivity Serial Ports USB rq me Mpp o e i ai ior a E Tate Daal USB Networking Port for communication with P
6. rt in full duplex mode To terminate select one of the DIP Switches and configure it based upon the option that is desired SW4 ON enables MJ1 RS485 port termination 121 Ohms OFF disables MJ1 RS485 port termination 3 2 2010 Page 3 of 4 1037 MANO884 04 EN Specifications Installation CAN Network Port and Wiring 5 Safety When found on the product the following symbols specify arning Electrical arning Consult Shock Hazard user documentation This equipment is suitable for use in Class I Division 2 Groups A B C and D or Non hazardous locations only WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been switched off or the area is known to be non hazardous AVERTISSEMENT RISQUE D EXPLOSION AVANT DE DECONNECTOR L EQUIPMENT COUPER LE COURANT OU S ASSURER QUE L EMPLACEMENT EST DESIGNE NON DANGEREUX CAN Connector Use the CAN Connector when using CSCAN network WARNING To avoid the risk of electric shock or burns always connect the safety or earth ground Torque rating 4 5 7 Lb In before making any other connections 0 50 0 78 N m WARNING To reduce the risk of fire electrical shock or physical injury it is strongly recommended to NET1 Port Pin Assignments fuse the voltage measurement inputs Be sure to locate fuses as close to the source as possible Pin Signal Signal Description Direction _ Ca poo Vvo o CANGoid J 2 CNL CANDatalow
7. uction and operation of this equipment and the hazards involved should install adjust operate or service this equipment Read and understand this manual and other applicable manuals in their entirety before proceeding Failure to observe this precaution could result in severe bodily injury or loss of life This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Power Connector Radiated Emission Compliance For compliance requirement a ferrite Horner P N FBDO06 supplied Power Up with the unit needs to be placed on the AC DC line with one loop Connect to Earth Ground Apply 10 30 VDC All applicable codes and standards need to be followed in the installation of this product Screen lights up Adhere to the following safety precautions whenever any type of connection is made to the module Torque rating 4 5 7 Lb In Connect the safety earth ground on the power connector first before making any other connections 0 50 0 78 N m When connecting to electric circuits or pulse initiating equipment open their related breakers Do not make connections to live power lines Primary Power Port Pins Make connections to the module first then connect to the circuit to be monitored Pin Signal Description