PSU04 - Power Supply Unit

image

Contents

1. Short circuit lt 2 sec Current limit to 1 5A max per output Short circuit gt 2 sec Output will switch to OFF 65 sec cycle time for switching the output to ON again if the short circuit has been removed Mains power connector CE 90V 250V 50Hz 60Hz 4 o Ey Inlet connector for non heating apparatus For mains power connection with the enclosed mains connection cable 13 PSUO4 CDSVAN Earth connection Terminal connection for additional earthing Left beside the mains power inlet connector To avoid any power stroke the metal housing of the PSU04 must be connected to earth via mains cable i For low impedance grounding the metal housing of the PSU04 can be additionally connected via extra ground at this earth connection on the backside of the unit Air outlet rs d op Allow proper air circulation to prevent internal heat built up AN Do not block the ventilation holes RJ45 connections PC IN i PC Two connectors for the connection of the CDSVAN PC with CAT5 cable for the transfer of up to 32 language channels uplink downlink from to PC DSP Card UNITS 1 UNITS 2 LINK OUT 1 LINK 14 CDSVAN PSUO4 Two connectors for the connection of additional interfaces e g AD DA Converter B8 downlink UNITS 1 UNITS 2 UNITS A 1 UNITS A Two connectors for the connection of next units with CAT5 cable for the transfer of up to 32 language channels with 48VDC
2. Liquids avoid penetration of liquids into the housing Power sockets operate equipment only with power sockets that are connected to ground according to the relevant specifications and regulations Warning Never expose equipment to rain or humidity Rough handling of the equipment such as strong shocks or vibrations may result in damages Inappropriate handling and storage which is not conforming to the operating instructions may also lead to equipment damages PSUO4 CDSVAN CDSVAN PSUO4 Table of contents Abo t this manual gr e 6 AA iin 6 Important FeMarkS ccccccccecccscescccecscsececcecdecsecssseccscccecssevesssaccsseccscsseassececsssccesseccesscsecssccessecetsevessecensseces 7 For customers in the EU and in the USA ccsssssassssnnsnusssnnsnnnsnnnnnnnsnnsnnnsnnnnnnnnnnnsnnnnnnnnnnsnnnssnnsnnssnsssnsssssssnnssnnnnne 7 Mix A O NN 7 Installation PR 7 E AA TT 7 acria alib ener PTT Leer Eee see 7 HIC PE O IE EE E I ON OEE E E TOE E OTE ETO 8 The PSUO4 Power Supply Unit eesssssssnsssssnsesssnsenssnnesnsnennsnunsnsnsnnnsnnnnnsnnnnnsensssnnnnsnsnnnsnsnnnssnnnsnnnnnsennsnsens 9 NR A 9 Optional accessories not in delivery usessesessssssnssnsnsnsnssnsnsnssnnnsnssnsnnnnnssnnnnnnsnsnssnsssnsnnnnnnnnnsnsssnssnnnnsnsnssnsnnsnnns 9 CDSVAN System Components s0ss00sssssussnsnnsnnnsssnnsnssnsnnnnnnsnnsnsnnssnsnnsnnsnns
3. in this manual could void your authority to operate this equipment The equipment must be connected to earth Safety Check that the operating voltage of the unit is identical with the voltage of your local power supply If a voltage conversion is required consult your BRAHLER ICS dealer or qualified personnel Should any liquid or solid object fall into the housing unplug the unit and let it check by qualified personnel before operating it further Unplug the unit from the power outlet or set the main power switch to OFF if it s not used for several days To disconnect the cord pull it out holding the plug Never pull the cord itself Installation Allow proper air circulation to prevent internal heat built up Do not place the unit on a surface that may block the ventilation holes Do not install the unit in a location near heat sources or in a place exposed to direct sunlight excessive dust humidity mechanical vibration or shock To avoid moisture condensations do not install the unit where the temperature may rise rapidly Cleaning To keep the housing in its original condition periodically clean it with a soft cloth Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet Repacking Save the original shipping carton and packing material they will become useful if you ever
4. no 05 4051 Digital Chairman s Unit with language selector and RFID card reader for up to 32channels built in version DDVS9 Art no 05 4033 Dual Digital Delegates Unit with language selector for up to 32channels PV9 Art no 05 4036 Digital Chairman s Unit with language selector for up to 32channels DOLV Art no 05 4330 Digital Interpreter Console for one interpreter for up to 32channels PSUO1MA Art no 05 4211 Power Supply Unit for Interpreter Consoles channel selectors with data refresh PSUO1SL Art no 05 4210 Additional Power Supply Unit for Interpreter Consoles channel selectors with data refresh B8 Art no 07 0250 AD DA Interface RSP8V Art no 05 2070 Digital Distribution Amplifier for channel selectors LAN Cables different lengths available CAT5 EIA TIA 568B AWG 24 26 10 CDSVAN PSUO4 Operating controls Front view CDSVAN PSUDA UNIS ANS2 A B A 889 88 888 GG The front side of the PSU04 is equipped with 1 power switch with green power on light indication 4green LEDs for 48VDC output indication 4red LEDs for short circuit indication AN The failure can not be removed by switching on and off the system This could damage the output line Also do not plug and unplug the connector of the faulty line 11 PSUO4 CDSVAN Rear view y t
5. 1 3A nominal UNITS 1 UNITS 2 UNITS B 1 UNITS B Two connectors for the connection of next units with CAT5 cable for the transfer of up to 32 language channels with 48VDC 1 3A nominal UNITS 1 UNITS 2 DIP switches OFF 100R OFF 100R DIP switches for termination 100 Ohm of the LINK outputs DIP switches SHORT LONG SHORT HI 1234 ON LONG DIP switches for adapting of different cable length 15 PSUO4 CDSVAN DIP switch settings Termination of LINK connectors Electrical digital data lines have to be terminated to avoid data transmission errors The 2 generation of CDSVAN delegate units interpreter consoles PV9 DV9 DDV9 EDV9 DOLV E are equipped with automatical termination For use with previous versions of delegate units interpreter consoles please contact Br hler ICS for information Please use the following settings Unit connected to LINK Set single switches 1 2 to OFF No unit connected to LINK Set single switches 1 2 to 100R Cable length at UNIT PC connectors Different settings are needed for short or long cables en Please use the following settings Short cables 20m at UNITS A B Single switch 1 UNITS A and or 2 UNITS B to SHORT Long cables gt 20m at UNITS A B Single switch 1 UNITS A and or 2 UNITS B to LONG Maximum number of units The maximum number of units which can be powered at one output depends on the necessary cable len
6. NIS 5 04 eee eee A e deep da AA quo et epe eve uu Aisa 16 Troubleshooting ol CRR 17 hn dE 18 Technical data P 18 Block diagram eere A NT 19 xddijiddigw 21 Table of language signs 150639 pL 23 Contact TINTOPMATI ON Etc 25 PSUO4 CDSVAN About this manual Symbols The meanings of the symbols and fonts used in this manual are as follows Indicates an important note or instruction if not followed the operation of the unit the security of your data or even of your health are put at risk i Gives supplementary informations remarks and tips as Describes activities that must be performed in the order shown Texts in bolded letters require your special attention CDSVAN PSUO4 Important remarks For customers in the EU and in the USA The equipment is complying to the standards of the CE regulations These standards are specified to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment The equipment can radiate radio frequency energy and if not installed and used according to the user manual it may cause harmful interference to radio communications Any changes or modifications that are not expressly approved
7. UNBB UNSA l 4 y WEB WNBA 00008 E38 3 CO The backside of the PSU04 is equipped with Mains power connector Screw for earthing Air outlet for ventilation RJ45 connectors 2 PC IN 2 LINK OUT 2UNITSA 2UNITS B 2DIP switches OFF 100R 2 DIP switches SHORT LONG 12 CDSVAN PSUO4 Set up Before power on the power supply unit PSU04 please connect the necessary cables Then proceed with the DIP switch settings regarding to your specific system After correct DIP switch settings and termination see chapter DIP switch settings you can power on the PSU04 The green LED in the mains switch and the green LED s from the connected lines light up in case that the installation is correct In case of a short circuit the corresponding red indication LED on the front panel will light up See chapter Short circuit protection Operation ON OFF switch 0 Power ON OFF switch with power ON indication Green light Output indication Green LED for 48VDC output indication UNITS 1 A B and UNITS 2 A B Short circuit indication For power failure indication short circuit UNITS 1 A B and UNITS 2 A B Short circuit protection The 4 outputs of the PSU04 are electronically short circuit protected In case of a short circuit the output will be automatically switched off A corresponding red LED on the front panel indicates this
8. according cable Change the relevant unit Check cables connections and remove short circuits Do not switch on and off the PSU trying to remove the short circuit Also do not plug and unplug the connector of the faulty line Cracks and distortion on the audio signal The number of connected units at the output is too high The maximum cable length per output is more than 100m Wrong setting of the DIP switches Reduce the number of connected units at the outputs Reduce cable length to 100m maximum Check the DIP switch settings 17 PSUO4 CDSVAN Appendix Technical data Connections e PC IN 2 x RJ45 socket for the connection of the CDSVAN PC with CAT5 cable for the transfer of 8 language channels e LINK OUT 2 x RJ45 socket e UNITS 4 x RJ45 socket for the connection of next units with CAT5 cable for the transfer of 8 language channels with 48VDC 1 3A nom Features e Green lighted mains switch for power ON indication e A green LEDs for 48VDC output indication e 4 red LEDs for short circuit indication at the corresponding 4 outputs e 2 DIP switches for adapting of different cable lengths e 2 DIP switches for termination 100 Ohm of the LINK outputs Short circuit protected outputs e Short circuit 2s Current limit at 1 5A max per output e Short circuit gt 2s output will switch OFF e 65s for switching the output ON again if the short circuit has been
9. an Oriya Oromo Pashto Pashto Pushto Persian Polish Portuguese Punjabi Quechua RM RO RU SM SG SA TN GD SR ST SN SD SI SS SK SL SO ES SU SW sv TL TG TA TT TE TH BO TI TO TS TR TK TW UK UR ZU VI vo CY RhaetoRoma Rhaeto Romance Romanian Russian Samoan Sangho Sanskrit Satswana ScotGaelic Scots Gaelic Serbian Sesotho Shona Sindhi Singhalese Siswati Slovak Slovenian Somali Spanish Sundanese Swahili Swedish Tagaiog Tajik Tamil Tater Telugu Thai Tibetan Tigrinya Tonga Tsonga Turkish Turkmen Twi Ukrainian Urdu Uzbek Vietnamese Volap k Welsh WO Wolof XH Jl YO ZU Xhosa Yiddish Yoruba Zulu 23 PSUO4 CDSVAN 24 CDSVAN PSUO4 Contact information Head Office BR HLER ICS Konferenztechnik International Congress Service AG P O Box 3264 D 53627 K nigswinter Germany Auf der Alten Burg 6 D 53639 K nigswinter Germany Tel 49 0 2244 930 0 Fax 49 0 2244 930 450 http www braehler com Event Technology Tel 49 0 2244 930 200 Fax 49 0 2244 930 430 E Mail rental braehler com Conference Technology Tel 49 0 2244 930 0 Fax 49 0 2244 930 450 E Mail sales braehler com 25 brahler Phone 49 0 2244 930 0 www oh com BGE PSU04_R1 3 doc 05 4202
10. brahler C D S V AN Digital Conference Management System PSUUM Power Supply Unit Operating instructions REV 1 3 1 Printed in Germany Should you have any questions about this manual please contact Br hler ICS Konferenztechnik International Congress Service AG Auf der Alten Burg 6 D 53639 K nigswinter T 49 0 2244 930 0 E sales braehler com You will find further information about our products on the internet at www braehler com 2008 BR HLER ICS AG K nigswinter Germany All rights reserved especially also partly the translation reprint reproduction through copying or other similar methods BR HLER ICS reserves the right to make changes without notice Operating instructions COSVAN BGE PSU04_R1 3 doc Aug 09 CDSVAN PSUO4 L gt e DANGER OF ELECTRIC SHOCK DO NOT OPEN DEVICES Do not open housing with mains cable connected Maintenance operations may only be done by qualified personnel Our equipment and installations have been built and tested according to the latest state of the art In general conditions they do not require any special maintenance However please be aware of the following Positioning secure and stable position of the equipment Ventilation operate equipment with proper ventilation Avoid heat sources such as heating radiators etc Mains connection pass all power cables so that they will not be damaged Cables connection avoid trip traps
11. d period of repair Please contact us before you return equipment in order to find the most efficient way of sending RMA number Article description Serial no Code Delivery note no Invoice no Reason for return Fault description Company Contact person Phone Fax Notes Comments Transport damages have to be reported immediately to the responsible forwarding agent Remarks for Non EU customers Please add to each return a delivery note or a proforma invoice addressed to Br hler ICS AG K nigswinter with following statements Reason for return repair or credit note Exact declaration ofthe goods exact no of pieces article no model serial no Price which was invoiced by us better our invoice no with date Return shipments from Non EU countries have to be sent either by air freight to Cologne airport to the attention of Calenberg Oversea Logistics Mrs Taxacher Welser Str 8 51449 K ln Tel 49 2203 3592 838 or by the following courier services DHL Express Federal Express TNT Worldwide Express UPS Express Please do not use any other courier service because only the four companies mentioned above perform return shipments To enable quick and cost efficient customs clearance kindly take care that the airway bill mentions a return for repair as well as b the customs tariff code number of the goods which will be advised by us together
12. gth within the customer specified system For standard applications up to 20 units per output are possible 16 CDSVAN PSUO4 Troubleshooting table Error description After powering up the PSU04 the unit doesn t work Green indication LED in mains switch is off Error cause No mains power Error solution Connect the mains power cable to the power outlet Unit doesn t work All LED s on the front panel are off The internal power supply is defective Contact Br hler ICS for maintenance Caution Qualified personnel may only execute maintenance operations After powering up the PSU04 the connected units in one ore more lines do not work One or more of the 4 red LED s on the front panel light up The number of connected units at the output is too high The maximum cable length per output is more than 100m Without additional power supply PSUO1SL The cable connectors are not properly connected to the sockets of the units Connection cable in the corresponding line possibly defective The automatic termination of the last connected unit in the line is defective Short circuit at the corresponding outputs Reduce the number of connected units at the outputs Reduce cable length to 100m maximum or insert additional power supply PSUO1SL Check all cable connections Disconnect all units Connection of one unit each until the failure appears again Exchange
13. have to ship the unit In this case please keep the manual together with the unit For maximum protection re pack the unit as originally packed from the factory If not supplied with the equipment a complete transportation and storage box system is available from BRAHLER ICS We recommend using this system for long term protection and care PSUO4 CDSVAN General Please keep this manual together with the PSUOA If you pass on the unit to other parties please include this manual Please read the manual carefully taking special care when you see this symbol as indicates important N information C This product conforms to the standards of the European regulations Further information is available on request li The warranty invalidates if you cause generate or precipitate inappropriate use or handling of the unit CDSVAN PSUO4 The PSUO4 Power Supply Unit Thank you for choosing this product of BR HLER ICS The PSU04 is a power supply for conference units to use within the CDSVAN system for power supply and data refresh It supports up to 32 channels The unit will be directly connected to the CDSVAN PC and can control delegate units or interpreter consoles at 4 outputs LEDs on the front panel are showing the operating status of each output The maximum number of units which can be powered at one output depends on the necessary cable length within the customer specified system For standard application
14. nnssnnnnsnnsnnsnnssnnnssnssnssssnnnsnnsnssnsnsssnnse 10 Operating ESI DISSERT IIT TII snseh sure ee nnnnensenen ten ne stennsnceeschrneereehe tere 11 Front OA 11 AA AUC 12 kim M 13 UTEMPBIIPEREORIISOOTOIIANHITCOUTILILOSUTODOICTULUDI 13 ONO FE S uic E A nein AAA AAA AA AAA A 13 Q tput indica HONA eienares nae oaeee iii 13 Short circ tindicatio Neissira Be er a E eoe ee a a a aa ie ida 13 Short Cireuitprotection Em 13 MEN A A 13 Earth CONMCCH ONS ns A ee nee ond A TOE diee ete e nee Teen Pede ios 14 yg M 14 RIAD CONNECT ree s eo e EE eR AA AEREA Vv TV E PES T EE AAA 14 PC CINIaes eiie IE IER dei e SERE N 14 Bi Sup EE 14 UNS A EE 15 SA ANN 15 DIP switches OFF 100R ns x 2 15 DIP switches SHORT LONG 2 2 se ae vate aoi e t ee e Ra e nee VET SEESE 15 DIP SWiLchsettings voee sep eae tete iss an De ere ee EE e ute rete tnum dedit 16 Termination of LINK connectors eeeeeee eese esee eene nenne eene non reno eese sehn eeee enhn eese nnne ese senes essen nennen nennen 16 Cable length at UNIT PC Connectors e eieoe iere e eee eere eoe no so nean no anna eo aee aeo nean oso see e aoo e e na o aene ao eae a pna cus 16 Max mum number of U
15. removed Power Supply e Mains power 90 250 VAC 50 60 Hz e Power consumption 300VA max Housing e 19 2 HE Aluminium silver anodized eWxHx D 433 x 88 x 285 mm Weight e 5 kg Accessories not included in delivery e CAT5 cable EIA TIA 568 shielded different cable lengths available 18 CDSVAN PSUO4 Block diagram General overview of COSVAN components el CDSVAN Computer a om Remote Systems DV9 Digital Delegate Unit PSU04 Power Supply Unit DSP6 PCI Card MSI8V Compact Transmitter HLN82 INFRACOM High Power Radiator IRX INFRACOMO Receiver Camera Control RSP8V Digital Distribution Amplifier EWD216 Channel Selector me INIQUT B8 AD DA Interface To PA system MotorMixer Remote Level Control analog in 19 PSUO4 CDSVAN 20 SERVICE FORM Material return shipments for repair service or guaranty purposes please send to BRAHLER ICS Konferenztechnik AG Auf der Alten Burg 6 D 53639 K nigswinter Germany Phone 49 0 2244 930 100 Fax 49 0 2244 930 450 Dear customer Please ask our sales staff for the RMA number Return of Material Authorization Without RMA number a treatment is not possible Please always include this service form fully completed with any complaint or repair wish you may have Please note that only returns with the proper and complete paperwork can be dealt within time A detailed fault description will reduce costs an
16. s up to 20 units per outputs are possible The 4 outputs of the PSU04 are electronically short circuited protected In case of a short circuit the output will be automatically switched OFF which is indicated by a red LED on the front panel When the short circuit has been removed the output will be automatically activated At the LINK output e g the BR HLER AD DA Converter B8 can be connected Content of basic delivery 1 Mains power cable 2 metres black 1 Set of rubber feet 4 pcs for table assembly 1 Rack mounting set 19 silver anodized mounting brackets for rack assembly Optional accessories not in delivery CAT5 data cable several cable lengths available PSUO4 CDSVAN CDSVAN System Components CDSVAN discussion software Art no S5 0050 Microphone management software CDSVAN interpretation software Art no S5 0060 Interpretation system software DSP6 EDAT Art no 07 0275 C Digital Signal Processor Card with I O adapter EDAT DV9 Art no 05 4030 Digital Delegates Unit with language selector for up to 32channels EDV9 Art no 05 4040 Digital Delegates Unit with language selector for up to 32channels built in version EPV9 Art no 05 4050 Digital Chairman s Unit with language selector for up to 32channels built in version EDV9 RFID Art no 05 4041 Digital Delegates Unit with language selector and RFID card reader for up to 32channels built in version EPV9 RFID Art
17. with the return of material authorization number Any expenses duties and taxes incurred by deviant handling will be charged to the sender PSUO4 CDSVAN 22 CDSVAN PSUO4 Table of language signs 150639 AB AA AF SQ AM AR HY AS AY AZ BA EU BN DZ BH BI BR BG MY BE KM CT CA ZH CO HR CS DA NL EN EO ET FO FJ Fl FR FY GL KA DE EL KL GN GU HA IW Abkhazien Afar Afrikaans Albanian Amharic Arabic Armenian Assamese Aymara Azerbaijan Azerbaijani Bashkir Basque Bengali Bengali Bangla Bhutani Bihari Bislama Breton Bulgarian Burmese Byeloruss Byelorussian Cambodian Cantonese Catalan Chinese Corsican Croatian Czech Danish Dutch English Esperanto Estonian Faroese Fiji Finnish French Frisian Galician Georgian German Greek Greenland Greenlandic Guarani Gujarati Hause Hebrew HI HU KS RW KY RN KO KU LO LA LV LN LT MK MG MS ML MT MA MI MR MO MN NA NE NO oc OR OM PS FA PL PT PA QU Hindi Hungarian Icelandic Indonesian Interlinga Interlingua Interlinge Interlingue Inupiak Irish Italian Japanese Javanese Kanadian Kashmiri Kazakh Kinyarwand Kinyarwanda Kirghiz Kirundi Korean Kurdish Laothian Latin Latvian Latvian Lettish Lingela Lithuanian Macedonian Malagasy Malay Malaysiam Maltese Mandarin Maori Marathi Moldavian Mongolian Nauru Nepali Norwegian Occit