1. H603 counter has 0 3 micron sensitivity and six particle size channels 0 3 0 5 1 2 3 5 microns the data will be showed on the screen and can be saved according to the different room numbers and it also can be printed out by an optional printer or downloaded to PC Accessories Isokinetic Probe provided with counter used to connect to the inlet Purge Filter provided with counter used for self clean keeps external particles from contaminating sensor while purging sensor of internal particles Carrying Case protects the counter during shipment and storage Software CD used to download the data to PC RS232 cable used to connect the particle to computer Unpacking and Initial Inspection The particle counter is thoroughly inspected and tested at the factory and is ready for use upon receipt When received inspect the shipping carton for damage If the carton is damaged notify the carrier and save the carton for carrier inspection Inspect the counter for broken parts scratches dents or other damage If the carton is not damaged keep for reshipment For example you may want to reuse the carton when you return the counter for the annual factory calibration Safety information A Warning identifies a condition or action that poses hazard s to the user a CLJ H603 user manual 4 Caution identifies a condition or action that may damage the Particle Counter or the equipment under test Read the entire Users Manual b
2. to print out Measure Real time data screen Measure 2007 1 26 15 30 34 Room 0l Loc 01 Cyc 01 0 3 um 0 0 5 um 0 1 0 0 0 0 0 2 0 3 0 um 5 0 um REVIEW Auto Period 01 LOCs 03 SETUP This screen provides following indications a Date and time of the day b real time particle count information for each size range c Current room number d Current location number e Current cycle number f Period of sampling g Total number of locations h Count mode Auto or Manual the data will be saved according to different numbers times and locations in Auto mode and in manual mode the data is used to observe only and will not be saved CLJ H603 user manual 9 Data Review screen Review 2007 1 26 15 30 34 Data 000 Room 01 Loc 00 Cyc 00 0 3 um 0 5 1 0 2 0 3 0 5 0 MEASURE Erase SETUP This screen provides following indications Review xxx room number that have been tested and saved Room xxx to choose the inquired room number Loc xxx to choose the inquired location Cyc xxx the tested date and time of current data UCL to calculate the mean value and 95 upper confidence limit Print to print out the data selected when the counter is connected to a printer Erase to clean up the data that saved in the counter MEASURE to enter the test screen SETUP to enter the parameter setup screen CLJ H603 user manual 10 Using the counter Setting parameters There are two way
3. um in five minutes or not more than one particle per 0 5 cubic foot should be apparent This purges the Particle Counter Once the unit is purged resume normal use Remove the purge filter Connecting the particle counter to a PC To connect the Particle Counter to a PC 1 Connect the particle serial port to the serial communications port of the PC with the RS232 cable supplied with the instrument 2 Turn the Particle Counter on Enter the review screen CLJ H603 user manual 17 4 Access the utility software on the PC and run the program by clicking counter exe If the software does not work properly follow the instructions on the CD About software The software allows user to download the data saved in the memory of particle counter The software screen is as follow ie Par Port com Quit Get Index Get Data g Get index used to download the index the data saved in counter E Port used to select the serial port number Get buffer used to download the data user selected and the data will be saved as hr txt
4. 4 Press Run Stop to stop counting Auto mode used to counting according to the number of locations and number of cycles you have set and the data measured will be saved in memory and used for UCL calculation Enter the MEASURE screen by select measure on other screen 2 Setting the counting mode to AUTO mode Press Run Stop key to start counting the counter will stop counting automatically while the cycles measured reach the cycles you have set for each location and the data are saved in the memory for the future calculation After you finish the measurements of all the locations in one clean room if you start counting again the room number will increase by one automatically Data review 1 Enter the REVIEW screen by select REVIEW on other screen 2 Press k or gt to select room xxx or loc xxx or CLJ H603 user manual 13 cycle xxx 3 Press f or amp to change the value and the data saved will be displayed according to the room number location number and cycle number UCL calculation 1 Enter the REVIEW screen 2 Select the room you want to do the UCL calculation 3 Press K or toselect UCL 4 Press Enter to confirm first the Mean value will be displayed press Enter again the UCL value will be displayed Print Print data s
5. CLJ H603 user manual 1 INDEX INDEN nis ae E A E er EE S TE E E eee ree E 1 LET o E 20s E E E E A E E E E E E 3 PTEE T e EEE E E E E E I A E 3 Unpacking and Initial Inspection cc cceecceceseesseeeeseeceeeeeeeeeeeeseeeeseeeneeenseeensaeenes 3 AQUMEK StI frees sSechesa sas ctesadussacsaiusctassaversassdecsrisnaseciusseaus R 5 Function and Editor Key D finitions ress sie aisimi orr aE EE RER E 5 BaSe coenen EE E REE T EEE T SEEEN 6 LCD Sorens scescevssecscvsnctscevssctvecsvactvaevvnecvacevacevaeevagcvaccvacdiacsvaeevacevacdiacsdesvacvsacvvactiaeeie 6 Power On Screen Welcome Screen cccscceesseeesseeeeeeeeeeeeeeeeseeeseaeessaeeeaes 6 SGU SCTE eas sac sack eel EEE AAE ack sue denenees aug tiys antseesaevk ET 7 Measure Real time data SCreenans iicictscevaicd sciasacksteratensaeaanet steal aeaaneiciecanenaues 8 Data REVIEW SCLECIs is c csacseecvaesvascsaesvancvaagvancsaasvantuaatsanteaaiedateaaieaadeaaveasceaates 9 Using the Counter ss cvsexe cc2 5c canccanedsccvanesanaseaseencne naton se 0edanens Sesadesebentsecuatieanacetesced 10 SOUS parameters erne neee r r R RE 10 Setting dats and tines isene eee eer e e eN 10 Setting period means sampling time for each cycles Imin 10min Se lectaOlE Dk aea e a e E E E E E ds oases 10 Setting hold time means holding time between sampling cycles 10 Setting locations means how many locations you need to sample in one TOOD p a a teal ac ences tae 10 Setting cycles means how man
6. article Counter 1 Read Safety Information Remove the inlet Cover the stainless steel cap Set the power switch to on position Press the ENTER twice to show the MEASURE screen a PP Ye bd Press MODE to convert into manual mode the measurement mode is displayed at the left below corner of the screen 6 Press Run Stop Particle counting will then begin and the number of particles counted will be listed in a column opposite the size column 7 Press Run Stop again to stop counting The total number of particles counted during the time will be displayed Be sure to read the entire Users Manual for more detailed information Warning Do not attempt to sample reactive gases such as hydrogen or oxygen with the particle counter Reactive gases create an explosion hazard in the counter Contact the factory for more information Exposure to infrared radiation may cause eye injury Do not look into counter inlet tube while counter is on Function and Editor Key Definitions The following keys either control functions of the counter run stop print etc or are used to edit the various programming functions available locations hold time etc K gt Used to select the different functions and the different parameters 4 Used to change the parameters CLJ H603 user manual Enter Run Stop ON OFF Mo
7. aved 1 Connect the counter with printer by the print cable connect the power cord 2 Enter the review screen Display the data you want 4 Press k or toselect Print 5 Press Enter to confirm data of the location displayed will be printed out Data format INDEX 1 1 2 room location cycle DATE 07 3 24 TIME 9 45 PERIOD 1 VOLUME 2 83 sample volume 2 83L 2 1 0 5um 0 CLJ H603 user manual 14 5 0um 0 2 2 0 5um 5 0um Print results of UCL calculation Connect the counter with printer by the print cable connect the power cord 2 Enter the review screen Display results of UCL calculation 4 Press k or toselect Print 5 Press Enter to confirm data will be printed out Data format STATISTICS INDEX 1 2 1 average value of 1 location DATE 07 3 24 TIME 9 45 PERIOD 1 VOLUME 2 83 0 5um 1 5 0um 1 INDEX 1 2 2 average value of 2 location DATE 07 3 24 TIME 9 45 PERIOD 1 VOLUME 2 83 CLJ H603 user manual 0 5um 4 5 0um 0 MEAN 0 5um 5 0um 95 UCL 0 5um 8 5 0um 0 Clear memory mean value of the room 1 Enter the review screen 2 Press k or gt to select Erase Press Enter to confirm Select Yes Press Enter again to confirm Maintenance The particle counter contains no user serviceable parts To avoid elec
8. change the parameters 4 Press Enter to confirm Setting the unit default unit is 0 1 ft 1 Enter setup screen 2 Press K or toselect CONV xxx 3 Press or 4 to change the parameters NO ft3 m3 4 Press Enter to confirm Setting the alarm level only functional under manual mode Enter setup screen Press k or toselect Alarm xxx Press f or 4 to change the alarm level E p oe ma Press Enter to confirm Setting the channels need to be printed out 1 Enter setup screen Press K or to select the particle channel Press or 4 to change the setting e U P Press Enter to confirm CLJ H603 user manual 12 MEASURE There are two counting modes AUTO mode and MANUAL mode it can be set on the MEASURE screen by press Mode key and the setting will be displayed at the left below corner of the screen Manual mode used to observe the cleanness of the clean room the data measured will not be saved for UCL calculation 1 Enter the MEASURE screen by select measure on other screen 2 Setting the counting mode to MANUAL mode Press Run Stop to start the counting and the counting down time will be displayed on the screen
9. de Base Saves to memory the new setup data confirm the functions which you have selected Starts the count cycle and stops the count cycle Turn on off the screen for saving power Switches the count mode between Auto mode and Manual mode On the base of the Particle Counter are the connection ports for the RS 232 Modular Cable I O Port The Tripod Mount is also located on the base LCD Screens The LCD Display shows several different screens and menus Navigate through each using the keypad The following sections explain the different screens used by the Particle Counter Power On Screen Welcome Screen MODEL CLJ H603 Airborne Particle Counter Honri Airclean Tech Co Ltd 1a CLJ H603 user manual Setup screen SETUP Date YYYY MM DD Time HH MM SS Period xx min Hold xx sec LOCs xx CYCs xx Conv xx Alarm x M 0 3um v 0 5um 1 0um REVIEW M 2 0um M 3 0um M 5 0um MEASURE This screen shown above provides the followed information a Date the current date b Time the current time c Period length of time the test lasted each cycle d Hold length of time holding between cycles e LOCs Total number of locations need to be measured in one clean room f CYCs how many cycles will be taken every location g Conv unit converted between M and Ft or no conversion h Alarm setup the alarm level from 100 to 100 000 IN CLJ H603 user manual oo 1 Selection of channels user want
10. efore using the Particle Counter Warning To avoid electric shock body harm or damage to the particle counter please follow these safety guidelines e Use the Particle Counter only as described in the Users manual otherwise the protection by the instrument may be impaired e Do not use the Particle Counter in explosive atmospheres e The Particle Counter contains no user serviceable parts Do not open the instrument For service and battery replacement the instrument must be sent to Honri Airclean Tech Company e Have the Particle Counter serviced only by qualified service personnel e Inspect the particle counter before use don t use it if appears damaged e Always use the AC adapter charger and connector supplied with the Particle Counter appropriate for the voltage and outlet of the country or location in which you are working Caution To avoid possible damage to the Particle Counter e Avoid using the Particle Counter in an excessively dirty or dusty atmosphere Excessive particle intake can damage the Particle Counter e Remove the Probe Cover the black cap before use Not doing so can damage the Particle Counter e Do not use a wrench to connect or disconnect the Probe or intake nozzle The connection should be finger tight e If using the tilt stand hold the instrument while using the keypad CLJ H603 user manual Quick Start Ln The Particle Counter may be used directly out of the box To immediately use the P
11. s to enter the setup screen press any key after power on or select SETUP function at review screen and measure screen then press IENTER key to confirm Setting date and time Enter setup screen Press k or to select date xxx or the time xxx 1 2 3 Press or 4 to change the parameters 4 Press Enter to confirm Setting period means sampling time for each cycles Imin 10min selectable 1 Enter setup screen 2 Press or toselect period xxx 3 Press or 4 to change the parameters 4 Press Enter to confirm Setting hold time means holding time between sampling cycles 1 Enter setup screen 2 Press k or toselect hold xxx 3 Press or 4 to change the parameters 4 Press Enter to confirm Setting locations means how many locations you need to sample in one room 1 Enter setup screen 2 Press k or toselect LOCs xxx CLJ H603 user manual 11 3 Press or 4 to change the parameters 4 Press Enter to confirm Setting cycles means how many cycles you need to sample each location 1 Enter setup screen 2 Press k or toselect CYCs xxx 3 Press or 4 to
12. tronic shock injury or damage to the particle counter do not open the instrument For service or replacement of battery the instrument must be sent back to Honri Airclean Technology Co Ltd Cleaning the case Periodically wipe the case and holster with a damp cloth and mild detergent To avoid damaging the Particle Counter do not use abrasives or solvents to clean the case CLJ H603 user manual 16 Charging the battery and using the AC adapter Recharge the battery as soonas p appears on the display The ac adapter is used to recharge the battery as well as power the Particle Counter This feature allows the counter to be used while the battery is charging To connect the ac adapter charger 1 Plug the charger into the jack on the side of case 2 Plug the ac adapter into an ac outlet While the LED indicator on the charger is red it means the battery is in progress of charging when the LED turns green charging is finished The Particle Counter will take4 6 hours to fully charge Purging the particle counter sensor To avoid possible damage to the Particle Counter avoid using the Particle Counter in an excessively dirty or dusty atmosphere Excessive particle intake can damage the Particle Counter To purge the Particle Counter sensor 1 Screw the purge filter to the inlet 2 Operate the instrument under manual mode for approximately 15 minutes 3 On the average not more than one particle greater than 0 3
13. y cycles you need to sample each TOCA OTD os EAE ES F EEA EA E AE E 11 Setting the unit default unit is 0 1 ft asia ve suboailie vive S 11 Setting the alarm level only functional under manual mode 11 Setting the channels need to be printed OUt ec eecceesceeeeteeetteeeeeeeees 11 MEASURE oaceae saya onors spanner couavors eneaners agetvesuots EEA 12 Manual mode isenip E 12 AWO MOLE ear are SS Oe Pre ee Oe 12 CLJ H603 user manual 2 Pata revi W reire ere re ee E E E EE 12 UCL calculation A E E 13 Printe a ates ss ase A e E E E e a E E 13 Print Pata sayed sereeenm eren an ina n n ase eage A 13 Print results of UCL calculation ceccccesceseceeseeeeseeeeseeeeseeeeseesenes 14 IMaInten an Ce secere inseto e iaaeaie a ea iaoea aa aaeeea seara 15 Cl anin ethe CASG ee ccess ce ae totes acct ceva a E A EOS 15 Charging the battery and using the AC adapter cccecccesseeseeeeseeeeneeeeseeeeteeenes 16 Purging the particle Counter SCNSOL ccceeccceesecceeseceeeeeeeeeeseeenseeeseeeeseseeeneeeseees 16 Connecting the particle counter to a PC ceecceccccesseceseeeeeeeeeeneeeeseeeeseeenseeeeteeenes 16 PADOUL SO LGW AL sr es scar ave tcet oc a r a saat are a root dan siuy aeaea 17 CLJ H603 user manual be Introduction This operating guide describes how to use the Model CLJ H603 Particle Counter and provides complete operating application information for the particle counter The model CLJ

Download Pdf Manuals

image

Related Search

Related Contents

MONO BLP - Certificazione Energetica  Brodit 512432 holder  Samsung Samsung SM-C115 Наръчник за потребителя  VirtualSCADA® VS1-MT  Working Together (パンフレット)  [U1.02.00] Introduction au Code_Aster  smartfile smartfile  USER`S MANUAL - Global Test Supply  User`s Manual of Massage Hot Tub (SPA)  スタートガイド - Pianta  