Home
here - Meteorologica
Contents
1. cloud conditions are not alike Check the coming 5 9 To Determine the Calibration Factor CAL Sections for more detail on how to determine CAL The Cloud Effect on UVIndex 15 1 hold down the button to scroll the setting faster 1 hold down the button to scroll the setting faster 5 9 UV Index Mode To Determine the Calibration Factor CAL Determine the CAL by using the following rules Standard UV Generator 1 Correct UV Index The UV index produced _ Correct UV Index by a standard UV generator or other similar means ee 2 Exhibited UV Index The UV Index exhibited by the Watch when it is exposed to the previous UV Sensor standard UV generator y y 3 ADJ The percentage change of UV Index Exhibited Hence ADJ Correct UV Index Exhibited UV Index UV index Exhibited UV index X 100 the Watch 4 Calibration Factor CAL The value that to be ser ExFiGled UV indak selected for the calibration CAL 25 ADJ is obtained for determent of CAL Example 1 To adjust the UV Index from 4 8 Exhibited UV index to 4 0 Correct UV Index ADJ 4 0 4 8 4 8 X 100 17 CAL 25 ADJ Hence CAL 25 17 8 Example 2 To adjust the UV Index from 7 8 Exhibited UV index to 8 0 Correct UV Index ADJ 8 0 7 8 7 8 X 100 3 CAL 25 ADJ Hence CAL 25 3 28 To resume the Watch to its original setting for sensing UV radiation select the default value 25 as the C
2. 5 5 UV Index Mode How to Read UV Index Bar Segment amp Color Code 2 Bar Segments hence UVIndex 2 an 5 Bar Segments hence UVIndex 5 ms UV Index Bar Segment The color code categorized by the World Health Organization Green Yellow Orange Red Purple 0 2 3 5 6 7 8 10 11 Green Yellow Red Purple a UV Index Color Code UV Index 5 Color Code Yellow UV Index Bar Segment amp Color Code UV Index Bar Segment To provide user a quick concept about the Current and Peak UV Indexes this Watch exhibits them by displaying a different number of bar segments on the upper row of the display Whether the Current or Peak UV Index Bar Segment appear on the upper row of the display one exhibited bar segment equals one UV Index For example if there are 5 bar segments displayed on the upper row of the display the UV Index is 5 UV Index Color Code As categorized by the World Health Organization each UV index is matched with a color code Check the previous 5 1 UV Index Range Exposure Category and Color Code Section for more detail on the Color Code To provide user a quick concept about the color code of the current and peak UV index this Watch also printed green yellow red stand for orange and red and purple color on the display Read the color code of a UV index by checking the color background of the right most exhibited UV index bar segment For example if there are 5 bar segments displayed
3. UV Index Alarm Icon by bar segments Peak UVI Indicator Color Code Current UV Index Current Time UV Index Display hour minute Current UV Index second Peak UV Index represents UV Index Color Code Peak UV Index Current Time UV Index Display hour minut Peak UVIndex Roun minute Index info appears on the upper row Note 1 The Current UV Index info will appear in this display if the Current UV Index has been selected in the UV Index Mode Note 2 The Peak UV Index info will appear in this display if the Peak UV Index has been selected in the UV Index Mode Check the coming 5 4 Current amp Peak UV Index Display Section for more detail on how to select between Current UV Index and Peak UV Index The UV Index Alarm Indicator and the Current Time appear on the lower row of the display To Select between the Date Display and UV Index Display Press the start stop button once to select between the Date Display and UV Index Display 4 1 Current Time Mode To Set the Current Time hold hold mode t Leese start stop scroll the setting by je increment of 1 hold start stop scroll the setting je faster lap reset scroll the mode setting by decrement of 1 hold lap reset scroll the setting ke reset Secondtozero 12 changes to 24 24 changes to 12 start stop start stop
4. mode le mode mode l Timer Mode Setting Sequence lap reset i apresi To set the target time for the Timer Mode press and hold the mode button for about 2 seconds to select the setting display When the hour digits flash on the display press the start stop or lap reset button to set the hour by scrolling of 1 hold down the button to scroll the setting faster When the minute digits flash on the display press the start stop or lap reset button to set the minute by scrolling of 1 hold down the button to scroll the setting faster When the second digits flash on the display press the start stop or lap reset button to set the second by scrolling of 1 hold down the button to scroll the setting faster When the setting is finished press and hold the mode button to exit the setting sequence The setting display will change to Timer Mode automatically if no key stoke has been activated for about 3 minutes 23 8 2 Timer Mode Using the Timer beeps stop Timer Mode setthe Zero Display Stop Counting target lap reset time to 29 59 30 minute F f aD lstartstop Timer Mode Timer Mode Stop Counting Counting start stop t If a target time has been set for example 30 minutes press the start stop button once to start the countdown When it is counting press the start stop button once to stop
5. must provide proof of date of purchase We strongly recommend that you keep your sales receipt and all of the packing materials in order to take advantage of your Watch s limited warranty Include all accessories and operational manual when returning to the retailer A brief description of the defect and a copy or your sales receipt 27 UV Master Prevent You Getting UV Over Exposure 28
6. Current Time Mode Ollap reset or lap reset mode 12 24 second ace mode 4 hour lt minute 1 mode mode M D year DM mdse mode day month Current Time Setting Sequence start stop or lap reset faster day month changes to month day month day changes to day month To set the current time and date and their display formats press and hold the mode button for about 2 seconds to select the setting display When the 12Hr or 24Hr is flashing press the start stop or lap reset button to switch between 12Hr 12 hour format and 24Hr 24 hour format When the second flashes on the display press start stop or lap reset button to reset the second to zero If one of the setting items minute hour year month day is flashing press the start stop or lap reset button to scroll the setting hold down the button to scroll the setting faster When the M D or D M is flashing press the start stop or lap reset button to switch between M D month day and D M day month When the above settings are finished press and hold the mode button for about 2 seconds to exit the setting sequence The setting display will change to Current Time Mode automatically if no key stoke has been activated for about 3 minutes 5 0 UV Index Mode What Does the UV Index Mean Erythe
7. Sieatty In all of the UV Index displaying mode When the Time Current UV Index equal to or larger than the The UV Index Alarm Upper UV Index Alarm the whole UV Index Alarm Alam Sound and UV Alarm Indicator Indicator starts flashing on the display 13 5 7 UV Index Mode Setting the Upper and Lower UV Index Alarms To set the Upper Lower UV Index Alarm and calibrate the UV Index press and hold the mode button for about 2 seconds to select the setting display d EER o When the LO indicator appear Press the a increment of 1 faster start stop or lap reset button to select the W Istart st hold Lower UV Index Alarm setting among 0 to 25 Uvindex Mode 5 2 soni iptartston t select to turn OFF the alarm by scrolling of Current UV Index Display hold hold mode ose Le When the HI indicator appear Press the start stop or lap reset button to select the Upper UV Index Alarm setting among 0 to 25 select to turn OFF the alarm by scrolling of Note To control the UV exposure by a two level alarm set a smaller value for example 6 for the Lower UV Index Alarm and set a larger value for sutting Soquance example 10 for the Upper Index Alarm hold When the above settings finished either press tapreset Dapiresal and hold the mode button for about 2 seconds Scroll to exit the setting sequence or press the mode button once to calibrate the UV Index To calibrate the UV I
8. World Health Organization Hong Kong Observatory Further information 28 08 2003 1 www who int peh uv uvindex htm 2 www hko gov hk wxinfo uvindex english euvtoday htm 5 3 UV Index Mode How UV is Sensing D tesun lt Ultraviolet Radiation UV Sensor UV Index the Watch How UV is Sensing 2 R the Avoid Shelter ensor the UV Sensor directly to intenti geeni Unintentionally 3 Rotate the 4 Clean the lens Watch Slowly of the Watch with and Search for a Soft Cloth before Maximum Reading the measurement Notes to UV Measurement 10 This Watch uses a built in UV sensor to detect ambient Ultraviolet radiation which is then converted to UV Index The UV Sensor is the small spot that is located on the lower part of the dial Check the previous 2 0 Parts and Its Functions Section for the detail on the location of the UV Sensor Notes to UV Measurement To make an accurate result employ the following steps when taking a UV measurement 1 Position the UV Sensor directly to the source of radiation for example the Sun 2 Avoid sheltering the UV Sensor unintentionally 3 Rotate the Watch slowly and search for the maximum reading 4 Clean the lens of the Watch with a soft cloth before the measurement this practice allows NO dirt or dust sheltering the UV sensor During the first five minutes of UV Index Mode the Watch needs two seconds to get a reading After the first f
9. press the button once to turn ON the EL chapters back light for about 3 seconds 3 0 Functional Mode and Functional Display The Watch includes 5 functional modes They are the Normal Time Mode UV Index Mode Daily Alarm Mode Chronograph Mode and Timer Mode Every function mode may include one or more than one function display it provides supplementary features to the corresponding function mode To Switch among the 5 Functional Modes To select among the 5 function modes press the mode button following the adjacent figure To Switch among the Function Displays To select among the function displays check the coming chapters for the detail on how to switch among different function displays Current Time Mode mode button UV Index Mode Chronograph Mode mode mode button button Daily Alarm Mode Cintas Function Mode Selection Sequence Function Mode and Function Display 4 0 Current Time Mode Date Display amp UV Index Display Day of week Date Current Time The Current Time Mode includes two function displays They are the Date Display and UV Index Display Date Display The day of week and date appear on the upper start stop 2 hour minute fow of the display The current time hour minute Date Display een second appears on the lower row of the display wget wma 1 UN Indes Diy by bar segments UV Index Either the Current UV Index info or Peak UV
10. the counting As long as the timer is counting the countdown time will be displaying on the display continuously counting Timer Mode To Reset the Timer To reset the timer to the preset target time before counting to zero press the lap reset button once when the timer is stopped To count from a new target time set a new value for the target time Check the previous 8 1 Setting the Timer Mode Section for more detail on how to set the Timer Mode Timer Alarm Sound When it counts to the last 5 seconds the Watch will beep once for every second When it is zero the Watch will beep for about 10 seconds During this 10 seconds beep sound it can be stopped prematurely by pressing one of the buttons except the light button Note The adjacent diagram illustrates the flow among different functional displays only hence Timor Mode these displays DO NOT conform to fact in all Stop Counting instances 24 9 0 Specifications Current Time Mode Hour minute and second Month day day of week and year 12 24 hour format selectable Month day Day month selectable Auto calendar from year 2000 to 2099 Hourly Chime on the hours UV Index Mode Display range bar segment 0 to 15 Measuring range numeric 0 to 25 Resolution bar segment 1 UV Index Resolution numeric 0 1 UV Index Alarm 2 UV Index Alarms Color Code 4 colors Green Yellow Red and Purple Daily Alarm Mode Daily Alarm 1 daily alarm A
11. AL during the calibration 16 5 10 UV Index Mode Calibrating the UV Index start stop t starto t UV Index Mode Current UV Index Display hold hold mode t irose mode UV Index Mode Setting Sequence lapreset apreze 17 To Calibrate the UV Index When the settings of the previous 5 7 Setting the Upper and Lower UV Index Alarms Section are finished press the mode button once to calibrate the UV Index When the CAL indicator appears press the start stop or lap reset button to select the pre determined CAL between 0 to 50 by scrolling of 1 hold down the button to scroll the setting faster Check the previous 5 9 To Determine the Calibration Factor CAL for more detail on how to determine the CAL When the above settings finished press and hold the mode button for about 2 seconds to exit the setting sequence The setting display will change to UV Index Mode automatically if no key stoke has been activated for about 3 minutes 6 1 Daily Alarm Mode Setting the Daily Alarm Mode To set the Daily Alarm Time press and hold the mode button to select the setting display When the minute digits flash on the display press the start stop or lap reset button to set the minute by scrolling of 1 hold down the button to scroll the setting faster When the hour digits flash on the display press the start stop or lap reset button to set the hour by scrol
12. UV Master Prevent You Getting UV Over Exposure Instruction Manual 1 0 Introduction Thank you for purchasing this model Your It is recommended to have the battery Watch includes 5 functional modes They are replacement done by a certified service the Current Time Mode UV Index Mode Daily agency as this practice will maintain the water resistance standard ele Mode Chronograph Mode and Timer on your Watch This Watch equipped with an UV sensor that leat your Watch Ba NOT eee measures UV radiation in terms of UV index Watch to strong chemicals such as This model also includes 2 UV index alarms gasoline and alcohol as they will damage In addition to the UV sensing this model also your Watch included current time daily alarm chronograph and timer functions WARNING DO NOT use this Watch for commercial or Your Watch is carefully designed and A professional purpose produced in order to utilize this feature of your Watch it is advisable to use the Watch in Make sure that you fully understand the conformity with the below notes functions and limitations of this Watch before using it Read this manual before using the Watch Always compare the UV reading with the Avoid exposing your Watch to extreme one broadcasted by local weather station conditions for an unreasonable time i j Excessive exposure to UV radiation could Avoid rough use or severe impacts to your cause fatal harm to a human body always Watch f
13. ce to set between ON and OFF the Daily Alarm When the Daily Alarm Indicator yw appears the daily alarm is ON the watch starts beeping at the alarm time for about 30 seconds To Select between ON and OFF for the Hourly Chime Press the lap reset button once to select between ON and OFF the hourly chime When the Hourly Chime Indicator Q appears the hourly chime is ON the Watch will beep once on the hour 7 0 Chronograph Mode Chronograph Mode This Watch includes a Chronograph Mode it can measure 3 different types period of time 1 Elapsed time 2 Accumulative elapsed time and 3 Lap time 1 lap only Chronograph Display Mode Indicator Chronograph Time Chronograph 1 100 Second Time hour Chronograph Chronograph Chronograph Mod Time minute Zero Display Time second The display shows the Zero display if the Watch or the chronograph has been reset 0 The Chronograph Mode Indicator exhibits on the 1 Elapsed time a upper row of the display start stop start stop The chronograph time hours minutes seconds and 1 100 second exhibits on the lower row of o om gA the display AEE tea f Cor The maximum counting range of the start stop start stop chronograph is 9 hours 59 minutes and 59 99 v1 go g 3 Lap time I 1 lap only start stoy lap reset 1 lap only Fl pies i 10 20 30 40 time Elapsed Time Accumulative Elapsed Time and Lap Time setae S
14. ch exhibits UV Index User can make use of the exhibited UV Index to cross check his her exposure level and hence to taking the appropriate protections to safeguard his her body from the potential harms of UV radiation Source World Health Organization National Oceanic Atmospheric Administration Hong Kong Observatory Further information 28 August 2003 1 www who int peh uv uv_radiation htm 2 www cpc ncep noaa gov products stratosphere uv_index uv_information html 3 www hko gov hk wxinfo uvindex english uvbginfo htm 5 2 UV Index Mode Basic Sun Protection Messages 2 Stay Away From The Sun If the UV Index is Very High E a oe i an Long sleeved a Broad Brim Hat or and Loose fitting cetri Use An Umbrella 6 Apply UV Blocking Lotion Regularly 5 Wear UV Blocking Sunglasses 8 Avoid Protect Babies Tanning Beds and Young Child When you go out in the sun World Health Organization WHO suggests taking the following protective measures against UV radiation 1 Limit exposure during midday hours 2 Seek shade 3 Wear protective clothing 4 Wear a broad brimmed hat to protect the eyes face and neck 5 Protect the eyes with wrap around design sunglasses or sunglass withside panels 6 Use and reapply broad spectru sunscreen of sun protection factor SPF 15 liberally 7 Avoid tanning beds 8 Protect babies and youngchildren Source
15. ing Diseay the lap reset button once when the chronograph is stopped counting Elapsed Time start stop the chronograph is stop counting lap reset Note This diagram illustrates the flow among different functional 21 8 0 Timer Mode Timer Mode This Watch includes a countdown timer for timekeeping a fixed period of time target time The Target Time The target time is the time which the timer start down counting from The target time can be set by the user and its setting limit is 23 hours 59 minutes 59 seconds Check the coming 8 1 Setting the Timer Mode Section for more detail on how to set the Timer Mode Indicator Timer Mode Target Time Hour minute second Bo o i Mode Target Time 1 Single phase Timer Display g start stop Beep The iinet Made Indicator exhibits on the upper row of the display Ceo Ro Ro 0 The target time hours minutes and seconds 2 Multiphases gt exhibits on the lower row of the display down start stop start stop counting start stop beep Gn oe oe 3 Reset to Bees preset start stop flap reset target time start stop o 10 20 30 40 time Single multi down Counting amp Reset Sades Stop Counting gt Counting 22 8 1 Timer Mode Setting the Timer Mode To Set the Timer Mode hold tart ste Timer Mode Btartstop t start stop t hold hold mode mode F
16. ive minutes of UV Index Mode the Watch needs 10 seconds to get a reading 5 4 UV Index Mode Current amp Peak UV Index Display Current UV Index UV Index bar segment Color Code Current UV Index indicator Current UV Alarm Huinga Indicator UV Index Mode Current UV Index Display start stop Peak UV Index bar segment Peak UV Index Peak Indicator P a UV Index Mode Peak UV Index Display The UV Index Mode includes two functional displays They are the Current UV Index Display and Peak UV Index Display Current UV Index Display The Current UV Index Bar Segment displays on the upper row of the display The Current UV Index and UV Index Alarm Indicator display on the lower row of the display Note When this display has been selected and then the watch returns to Current Time Mode the Current UV Index Bar Segment and Current UV Index will display if UV Index Display is selected Peak UV Index Display The Peak UV Index Bar Segment appears on the upper row of the display The Peak UV Index and the UV Index Alarm Indicator appear on the lower row of the display Note When this display has been selected and then the watch returns to Current Time Mode the Peak UV Index Bar Segment and Peak UV Index will display if UV Index Display is selected To Select between the Current and Peak UV Index Display Press the start stop button once to select between the Current UV Index Display and Peak UV Index Display 11
17. larm Duration about 30 seconds 25 10 0 Limited Liabilities The Company is not liable for any damages caused by the product or the failure of the productto perform including any loss of profits or savings incidental damages or consequential damages There is no liability of the Company against any claim made by a third party or made by you on behalf of a third party Even if you have advised the Company or an authorized representative of the Company of the possibility of any such damages this limitation will still be in effect This limitation of liability cannot be waived or amended by any person This limitation is applicable underthe condition that whether damages are sought or a claim made under thelimited warranty as mentioned in this manualor as a tortclaim including negligence and strict product liability a contract claim or any other claim 26 Chronograph Mode Resolution 1 100 second Counting range 9 hours 59 minutes 59 99 seconds Measuring mode Elapsed time accumulative elapsed time and lap time 1 lap only Timer Mode Resolution 1 second Setting limit 23 hours 59 minutes 59 seconds Alarm sound One beep at the 5 4 3 2 and1 second s Alarm sound Beep beep beep at 0 second Alarm duration about 10 seconds Others Electro luminescent back light The Company disclaims allwarranties that are not stated in the express limited warranties in this manual We makes no other express or implied wa
18. ling of 1 hold down the button to scroll the setting faster When the setting is finished press and hold the mode button to exit the setting sequence The setting display will change to Daily Alarm Mode automatically if no key stoke has been activated for about 3 minutes Daily Alarm Sound When the daily alarm is ON the watch starts beeping at the alarm time for about 30 seconds When the beeps sounds it can be stopped prematurely by pressing one of the buttons except the light button Daily Alarm Mode _ Start stop t hold start stop mode hold hold mode mode gt ae t mode Daily Alarm Mode Setting Sequence hold lap reset lap reset 19 6 0 Daily Alarm Mode Daily Alarm Mode Current Time Mode Indicator Daily Alarm Mode Alarm OFF amp Chime OFF t start stop Daily Alarm Indicator Daily Alarm Mode Alarm ON lap reset Hourly Chime Indicator Daily Alarm Mode Chime ON 18 This Watch includes a daily alarm for user s convenience The daily alarm can be set by the user Check the coming 6 7 Setting the Daily Alarm Mode Section for more detail on how to set the Daily Alarm Mode The Daily Alarm Display The Current Time hours minutes shows on the upper row of the display The Alarm Time hours minutes shows on the lower row of the display To Select between ON and OFF the Daily Alarm Press the start stop button on
19. mal Action Spectrum Source The International Commission on Illumination The UV Index is a measure of the solar UV ultraviolet intensity at the Earth s surface relevant to the effect on human skin The skin damaging UV radiation is governed by the erythemal action spectrum the black line in the adjacent figure This spectrum has been adopted by the International Commission on Illumination CIE to represent the average skin response over the solar UV spectrum Source World Health Organization National Oceanic Atmospheric Administration Hong Kong Observatory Further information 28 August 2003 1 www who int peh uv uv_radiation htm 2 www cpc ncep noaa gov products stratosphere uv_index uv_information html 3 www hko gov hk wxinfo uvindex english uvbginfo htm UV Index Exposure Color Range Category Code 3 5 Moderate Yelow UV Radiation Exposure Categories Source World Health Organization 5 1 UV Index Mode uv index Range Exposure Category and Color Code As categorized by the World Health Organization the UV Index ranges between 0 and 11 Each UV index is matched with an exposure category and color code Check the adjacent table for more detail on UV index range exposure category and color code The lower the UV Index the lower the UV exposure category the less likely the damage to our body while the higher the index the higher the UV exposure category the more likely the damage to our body This Wat
20. ndex check the coming 5 8 Precautions to UV Index Calibration 5 9 To Determine the Calibration Factor CAL and 5 10 Calibrating the UV Index Sections for more detail on the UV Index Calibration 14 5 8 UV Index Mode Precautions to UV Index Calibration The Watch s UV sensor hasbeen calibrated May in the factory The most possible cause 15 minute mean Instantaneous iation i i minute mi NOT pte for deviation is the Ozone thickness A equal to difference between the place of use and cali bration of the Watch For normal usage you EA E Oae aep Sa should not need to calibrate the Watch again The Time Frame Effect onUV Index DO NOT attempt to calibrate the UV index unless you have the following items to determine the Calibration Factor CAL 1 Standard UV generator or Nn hesun lt 2 Correct immediate local UV Index ie DO NOT use the UV Index broadcasted by the raviolet Radiation local weather station as the correct UV index it may NOT the correct one at your place when you Pap calibrating your Watch this is because I 1 Weather stations usually broadcast the 15 Location a MEENE minute mean UV Index to public It is different with aniHigher witha Tawar from the instantaneous UV radiation that your UV Index UV Index Watch is now sensing 2 Cloud condition affects UV Index Hence the o o UV Index at your location may not be i identical to the one at weather station if the two
21. ollow the Basic Sun Protection Messages by the World Health Store your Wath in dry place when it is Organization when you go out in the Sun not in use 2 0 Parts and Its Functions mode Button UV Index Press the button to select among the 5 function Color Code modes In function modes Press and hold the button to select setting display During setting displays Press ian the button to select among different setting items Press ight Ko StartiStop and hold the button to exit setting sequence start stop Button In Current Time Mode Press the button to select between the Date Display and UV Index Display In Mods LY Lapireset Daily Alarm Mode Press the button to select between ON and OFF the daily alarm In Chronograph Mode Biases and Timer Mode Press the button to start stop the UV Sensor counting In setting displays Press the button to scroll through the setting lap reset Button In Daily Alarm Mode Press the button to select between ON and OFF of the hourly chime In Chronograph Mode When counting press the button to select the Lap time display When stop counting press the button to reset to zero display In Timer Mode When stop counting press the button to reset the timer Note The operations of the buttons to target time In setting displays Press the are summarized in the adjacent __ button to scroll the setting paragraphs However for the detail light Button operations please check the coming In any mode
22. on the upper row of the display the color code is Yellow 12 5 6 UV Index Mode UV Index Alarm To prevent user getting UV over exposure this so apresente bye TAE PRANIN Watch includes two UV Index Alarms They are flashing bar segment represents by the Upper UV Index Alarm and Lower UV Index ae Y TH the flashing Alarm Mit bar segment Current UV Index bar segments These UV Index Alarms can be set separately by the user Check the coming 5 7 Setting the Upper UV Index Pasai and Lower UV Index Alarms Section for more Aien oon UV Index detail on how to set the UV Index Alarms UVIRIER MSIE When one UV Index Alarm has been set the Current UV Index Display corresponding bar segment will be flashing on the display iia UV Index Alarm Sound Nii In all of the modes Whenever the Current UV SiN Index is equal to or larger than the Upper or 1 the whole UV Index Lower UV Index Alarm the Watch starts beeping SNPS Alarm indicator flash beep for about 10 seconds the Upper p T conds UV Index Alarm Indi UV Index I seconds Index Alarm Indicator HI Alarm 7e the Ray of the UV Index In all of the UV Index displaying modes When the the Lower fa Current UV Index equal to or larger than the Uy Index gt a beer Lower UV Index Alarm the Rays of the UV Index wy for 10 A A P 1 the UV Index Alarm seconds Alarm Indicator starts flashing on the display eran ator apport
23. rranties including any implied warranties of merchantability and fitness fora particular purpose All impliedwarranties that maybe imposed by law arelimited to the terms of this limitation and thelimited warranty Some countries do notallow the exclusion of incidental or consequential damages or a limitation on how an implied warranty lasts Some exclusion or limitation of this limited warranty may notapply to you This limited warranty gives you specific legal rights and you may have other rights vary from country to country 11 0 Limited Warranty The Company warrant this unit to be free from defects in material and or workmanship for a 1 year period beginning from the date of purchase This warranty does not cover second hand ownership or products that are purchased for sale or lease to another This warranty does not cover damage resulting from acts of God lightning accident misuse improper installation or operation or unauthorized repair or alteration If this unit has become defective within the first year of purchase return it to the retailer where it is obtained with all of the original packing materials and parts for reconditioning or replacement Whether or not to replace or recondition the unit would be decided by the retailer The replaced reconditioned unit will be warranted for a period of 90 days or the remainder of the original one year period whichever is longer To obtain warranty service on your Watch you
24. top Counting Counting 20 7 1 Chronograph Mode Using the Chronograph In Zero Display press the start stop button once to start the counting When it is counting press the start stop button once again to stop the counting and the elapsed time of which the chronograph is counting will appear When the elapsed time is displaying repeat the Lap Time the chronograph is counting in the background i Chronograph Mode above mentioned key operations to get the Lap Time Display accumulative elapsed time or press the lap reset lap reset button to reset the chronograph ready for a new counting Check the below To Reset the Chronograph Section for more detail on how to reset the chronograph To Get the Lap Time When the chronograph is counting in the previous operations press the lap reset button to get the Lap Time Display the r and rr start flashing Chronograph Mode Chronograph Mode n A Zero Display Counting Display When the Lap Time is displaying the chronograph is counting in the background In Lap Time Display press the lap reset button once to return to the Counting Display When the Counting Display return press the lap reset button at any designated moment to get a new lap time the previous lap time will be erased To Reset the Chronograph displays only hence these To reset the chronograph to Zero Display press inal eances eer step Count