Home

ACB 4000

image

Contents

1. 2 5110097 Large glass suction 13 1 5110096 Flat glass suction cup 8 1 5111061 Handle for brushing 1 5111068 Brush 20 Mt 1 5111067 Brus 1 5111066 BFUSI XL 1 5111065 Brush AXL 7 1 210054 Mains cable with ferrite 1 PHOTO REF DESCRIPTION Un 5111000 High frequency coil 5111005 Large red mushroom electrode 1 5111047 Small purple mushroom 1 electrode 5111006 Pencil glass electrode 1 EMA 11 START MANUAL 5111010 5111014 5110095 5111002 5111015 5111097 5111096 5111061 5111068 5111067 5111066 5111065 210054 Neck glass electrode Aluminium indirect electrode Indirect spiral glass electrode Spray bottle Silicone tube set Large glass suction cup 13 cm Flat glass suction cup 8 cm Handle for brushing Brush brossage P 20 mm Brush brossage L 40 mm Brush brossage XL 55 mm Brush XXL 70 mm Mains cable with ferrite ACB 4000 12 START UP MANUAL ACB 4000 WINDOWS ACB 4000 includes three basic windows The FIRST one corresponds to the mechanical brushing The SECOND one corresponds to the high frequency module The THIRD one corresponds to the extraction and spraying module EMA 13 START UP
2. 4000 USER S MANUAL START MANUAL 4000 EMA 2 START UP MANUAL ACB 4000 INDEX M AN DA 6 reee 7 General MEME ERE 8 REC CO IS cen Gin Co LLL 9 ACCOSSOLIBS OS 11 Wi aa Er 13 Descripuon of tne COL 14 ADDUCACIONS ceva eas race winnie caine enue 16 Detailed description of each 17 i 18 19 BUS TTE TT 20 Start lo T 22 DOL 23 RON e ELIT LI ILI 24 AGH tregquenmcv Em Ec K aed ban Fa AN KEK AWA n 25 CCE EE TOT 25 Peripheral vasodilator n 25 moles ens dis OR S 25 High frequency kaka kaka ka 26 EMA 3 START UP MANUAL ACB 4000 FG COUEN 202 059025520 29100000300510 281540 202030 2024008401 26 Properties of high 26 High frequency in the beauty 27 FGM
3. ACB 4000 is composed of high frequency extractor spray and brushing units All these devices in one machine make of ACB 4000 a solid high quality indispensable element for the beautician and in aesthetic medicine since it allows to carry out all necessary facial treatments with only one apparatus EMA 8 START UP MANUAL ACB 4000 TECHNICAL FEATURES e This equipment combines the following functions in one unit high frequency brushing spraying and extraction Independent voltage control on each output Independent use of the various modules User friendly Provided with the necessary accessories for all functions Supply voltage 230 V 110V on request Weight 7 Kg Dimensions 360 x 260 x 110 5 mm Ground connection the machine is provided with a ground connection through its mains cable Connect to installations equipped with that connection e Safety the machine remains insulated from the mains through a transformer 29 This equipment uses radio frequency currents for treatments The possible radio disturbances have been minimised However conditions specific to the premises e g earth plate which resistance is too high can reduce even more these possible disturbances Additional measures can be taken to this end The following measures are recommended whenever possible a The presence of an independent earth conductor used for electro therapy equipments only b The equipments must be loc
4. BEAUTY TREATMENTS THAT CAN BE CARRIED OUT 1 Beauty treatment of blackheads and skin impurities It is a relatively slow treatment for which a great consistency from the client is necessary in the continuity of the treatment As the impurities of the cutis are produced periodically normally every beginning of winter it is convenient to begin the treatment when these impurities red and white spots blackheads have not yet excessively developped since they resist less at that stage This treatment consists of the known sparking or distance application The smooth electrode is used The intensity must be low Even so and due to the tickling produced by the shower of sparks produced the client may be somewhat nervous To reduce this tickling and relax the client place a folded tissue never fibre cloth between the electrode and the cutis The duration of the session must not exceed three minutes in any case During the development of the treatment the classic smell of ozone can be detected produced by the shower of sparks Thanks to this treatment the blood flow is improved and disinfected due to the action of the ozone 2 Beauty treatment of wrinkles eye bags crow s feet etc Two different techniques can be used for these treatments the first is carried out with the smooth electrode through direct application and the second is carried out with the metallic electrode through indirect application With the first one gently and sl
5. sensitivity 9 When the session is over put the potentiometer 9 to zero Turn off the main switch 2 EMA 38 START MANUAL 4000 2 SPRAYING The spraying technique completes skin cleansing treatment The finality of tonic microdiffusion is to help the treated pore close and produce a decongestive effect in the client The spraying must therefore be pleasant and homogenous EMA 39 START UP MANUAL ACB 4000 START UP U N E Check that the equipment is connected Activate the on switch 2 Join the silicone tubes supplied with the equipment with the tube corresponding to the spray 10 If the process turns out to be difficult blow inside the rubber tube the operation should then work Choose the tonics to spray and fill the bottles opening the microdiffusor cap Insert the free extremity of the silicone tube into its corresponding spraying bottle Turn on the compressor intensity button 9 and choose the power wanted Turn the bottle towards a clear space put the finger the hole located in the microdiffusing cap to spray the liquid The liquid spraying in particles EMA 40 START UP MANUAL ACB 4000 must be uniform Make sure that the spraying intensity is adequate using the potentiometer Unblock the hole with your finger to stop the spraying Once preliminary verifications have been done spray the liquid on the treatment area 8 When the treatmen
6. transmitting it in the form of light and ultraviolet radiation Electrodes with air produce a violet gleam They are called MacIntyre violet radiation tubes EMA 27 START UP MANUAL ACB 4000 Some electrodes contain a bit of mercury vapour and shine with a blue colour Some contain neon and shine with an orange colour As they are made of glass the ultraviolet produced cannot escape But be careful some electrodes made of quartz let fairly high doses of these ultraviolet radiation escape Electrodes made of quartz are not differentiated from the glass ones at a simple glance and are not available through suppliers of beauty salons They must not be used for beauty treatments Intensifying electrode mc In order to improve the efficiency of the e transmission of high frequency energy to the skin 2 internal wire the intensifying electrode has an internal wire that metal disc connects the contact terminal with a metallic disc located inside the glass vvhere the electrode touches the skin This means that more energy succeeds in getting to the skin Intensifying electrode Saturating electrode In the indirect method of high frequency application the client is charged with high frequency energy by fixing a saturating electrode while the beautician manually massages the treatment area Various types of saturating electrodes are available The most simple is a tube or metallic bar that fits inside the electrode holder hand
7. 18 START MANUAL 4000 BRUSHING MODULE The brushing of the skin allows to clean regenerate PP and soften epidermis This operation has to done very gently for too strong or violent application can damage the layer of live cells of the epidermis and thus diminish the natural defences of the skin The skin is an organ protecting the organism against environmental aggressions It usually resists the passing of any substance trying to introduce itself inside it That resistance is higher when the skin becomes saturated as a consequence of the secretions produced by the glands joining the skin by cosmetics and also when the keratinous layer is thicker than normal due to an accumulation of cells Hence the importance of a comprehensive cutaneous cleansing and hygiene before starting any treatment facial or corporal The brushing of ACB 4000 includes many accessories of various shapes and sizes easily interchangeable It has a motor allowing to adjust the speed and to reverse the rotation direction The effects of the brushes on the skin is that of a mechanic brushing that eliminates the dead cells of the epidermis together with a slight reddening that facilitates the subsequent product penetration It is mainly used to complete skin cleansing depth and to improve its response to beauty care Peeling effect The keratinous layer is the superficial layer of the skin and is made of dead cells rich in
8. MANUAL ACB 4000 Description of the controls 0 Fuse 1 Connection 2 on off switch 3 Povver control for the brushing TN 14 START UP MANUAL ACB 4000 4 Output for the brushing connection E 2 5 Switch for the rotation direction of the brushing 6 High frequency power control 7 Outlet for the high frequency connection 8 High Frequency Light indicator 9 Power control for the compressor extractor and spray 10 Output for the spray connection 11 Output for the extractor connection EMA 15 START UP MANUAL ACB 4000 APPLICATIONS These are some of the numerous treatments that can be achieved with the equipment ACB 4000 e Extraction of blackheads and other impurities of the skin using the Suction cups e Disinfection of the skin with high frequency after removing impurities e Tonic or infusion spraying to clear the skin or shut the pore e Elimination of dead cells located on the surface of the skin and interfering with the efficiency of beauty treatments EMA 16 START UP MANUAL DETAILED DESCRIPTION OF EACH MODULE 1 BRUSHING 2 HIGH FREQUENCY 3 SPRAY AND EXTRACTOR 4000 START UP MANUAL ACB 4000 1 BRUSHING e f The brushing unit corresponds to the first window of ACB 4000 The photo shows the positioning of the accessories corresponding to this application 1 EMA
9. T T C I I TI UTMMMTMT 38 Sc li j o ETT 39 Ds SEO 40 EE 41 San canan per RDA Gen Qe RA 42 Possible techfhical DFODIGImiS s s san nasaran ana n ba n zana ER dia k lA SEWE A WAR2 DRA WA 43 GUarantee ahd Sal Gly 44 Declaration OF 45 Manufacturer SS TO L ya kc yekl ana hekan ven eaten wenn A KNK RA k d n l n y 46 SUGGS S a ec CD 47 Notes and COMMENTS eut ena NANA DINDAR Wiya Ta UP EDU e Ta pA DAN gent 48 START MANUAL 4000 INTRODUCTION Thank you for the trust you placed in us and in the equipment you just acquired With it you will be able to bring the most advanced technology in electro aesthetics and to introduce a tool that will become essential to secure good results This equipment provides you with an advanced option of cleansing and facial treatment User friendly this equipment has been conceived to fully satisfy the requirements of the most demanding users This machine has been subject to technical and application tests to guarantee its quality and results Our company also provides practical and advanced courses in facial treatment technique This new service aims at giving the user the best knowledge possible in order to obtain high quality results Information on our courses is available in our web pages www ema es Before starting
10. and its antiseptic action reduces the presence of blackheads and other skin impurities It is also said that it is valuable in skins that tend to age where the stimulating action of the astringent firms but very temporarily It is also useful in skins with a problematic tendency for its antiseptic action and for its ability to burn blackheads Drying these impurities can be achieved by the elevation and angulation of the facial electrode over the blackhead in order to produce a shower of sparks or also by using along and narrow electrode especially conceived for impurities EMA 30 START UP MANUAL ACB 4000 Precautions and contraindications Contraindications of high frequency are almost non existent From this point of view the treatment is completely harmless But little accidental shocks that can bother the anxious client are easily produced First you must fully explain what the client will fee and particularly the sparking The treatment can frighten a client who does not know what to expect Then make sure that the client does not touch any nearby element Make absolutely sure that the hands are not close to the metallic edge of the seat or bed otherwise the current will pass to the ground from him across the metal Similarly it is also a good idea to remove any metallic object of jewellery particularly those that can be held freely over the clothes Elements adapting to the skin in a compressive way like wedding ring
11. session is between 5 and 7 minutes e Do not touch sensitive areas with the electrodes lips nipples etc e Touch the end of the electrode with a finger both when approaching the electrode towards the client and withdrawing it The beautician will have to enter in contact with the part furthest from the base of the glass to avoid the client startling with the unexpected sensation of the harmless Shower of sparks that he or she will receive at that time e Apply the high frequency preferably after the vapourization of ozone and before the face mask It is considered to be the ideal moment EMA 35 START UP MANUAL ACB 4000 3 SPRAY AND EXTRACTOR 5 anre fi compression unit corresponds to the third 2 T window of ACB 4000 Above are the accessories corresponding to that application 3 EMA 36 START MANUAL 4000 COMPRESSION MODULE lt Extraction and spraying are two functions 178 controlled by the compression module A common button sets the intensity for air suction and expulsion making its application easier in beauty D gt P s E treatments ACB 4000 simplifies the use of these n functions with a single handle and allows to go from one application to the other only by putting the intensity control to zero 1 EXTRACTION Extraction treatment with this equipment improves peripheral blood flow but it must not be abused or used in areas affected
12. up the equipment please READ CAREFULLY this MANUAL Failing to do so could turn out to be dangerous and provoke damage to third parties We invite you to contact us or our distributor for any doubt or query We would be delighted to assist you Yours sincerely The Management EMA 6 START UP MANUAL ACB 4000 SAFETY STANDARDS This equipment complies with the safety standards in force at the time of manufacturing However the following safety recommendations should be observed 1 Before handling the equipment read carefully this manual 2 The client s electrical safety is ensured by a double insulation from the mains Do not however connect to a socket deprived of an earth connection The machine must be connected to an earth plate provided with an earth conductor Never connect to a system deprived of a differential switch 3 Do not use on customers with a pacemaker 4 Always place the accessories when the power button indicates zero 5 This equipment must be used following the instructions of qualified personnel for example graduated beauticians WARNING This equipment is not a medico sanitary product not aiming at diagnosing controlling monitoring or relieving any disease injury or deficiency Always use cosmetic products complying with the law in force In case of doubts concerning the application on a specific client consult a specialist EMA 1 START UP MANUAL ACB 4000 GENERAL POINTS
13. Treguencyculrebitisiuiei xir na nay nan n daba ba 27 Applying high frequency to the cli ent hLkh kA k lllllk ljssk lkkkkkkkkkkkkkkkkkkk ka 27 Electrodes used Inidestrie L CS sana nanan nin RA ND AE KED G 28 Tasa electrode rrr rrr 29 Sat rating 29 Eec OF su ya ia ace lok b ke R k AKA N IRA NN Kn kO n WE S OYAK KO RN 30 Or NEAN T UIDI TINI 30 5 ava xr gc DID ov Ea EAD Ead ETE Ka dea 31 Skins that can benefit from high 31 Precautions and 32 Beauty treatments that can be carried 33 Beauty treatment of blackheads and skin impurities 33 Beauty treatment of wrinkles eye bags and crow s feet 33 Beauty treatment against dandruff and hair 1055 33 Other applications of high 34 go j ella emet DD DD 35 ane a ya n yaba CE 36 A S Dray and ara 37 38 4 4000 START UP MANUAL I pie Xt CLIO Ml
14. a and can be beneficial for dry skins EMA 29 START UP MANUAL ACB 4000 Physical effects of sparking We will now consider the conflicting effects of the sparking that accompanies the direct method These effects are dual the first is due to the stimulation and the second is due to the antiseptic effect A tickling effect is felt when the sparks activate the nerve endings in the skin This stimulates the sensations of the skin It also has an astringent effect firming the skin and closing the pores to reduce the secretion of fat Direct high frequency helps drying greasy skin and improves its texture The antiseptic action of high frequency sparking of has three aspects for which in theory it should be more effective The sparkles can burn and kill bacteria in the skin Sparking produces ultraviolet radiation that kill bacteria The sparkles jonize oxygen from the air forming ozone that also kill bacteria Oxygen 2 is converted into ozone Ozone is unstable and soon disintegrates Ozone gt Oxygen O2 and oxygen Oxygen atoms called rising oxygen or active oxygen are powerful oxidants and are lethal for microorganisms This treatment is characterised by the strong smell of ozone that accompanies the high frequency treatment Skins that can benefit from high frequency The effect of direct high frequency treatment is very valuable in greasy skins where its astringent action reduces the fat secretion
15. ated in a Faraday cage protected room Non ionising radiation at the different levels and powers of the equipment does not cause any effect harmful to health since its use does not require any further precaution from the person qualified to apply an appropriate treatment on the customer This symbol aims at dissuading the use of the apparatus by personnel non qualified or newly introduced to its use warning of the possible adverse effects that an improper use could provoke on the client EMA 9 START UP MANUAL ACB 4000 This equipment provides a special protection rate against electrical discharge particularly in relation with the authorised leakage current and the reliability of the earth connection This symbol shows that high voltage generated in the high frequency control output cannot produce an electric shock EMA 10 START MANUAL 4000 ACCESSORIES REF DESCRIPTION QIY 5111000 High frequency Colla 1 5111005 Large orange mushroom glass electrode 1 5111047 Small purple mushroom glass electrode 1 5111006 Pencil glass electrode een nn nnne 1 5111010 Neck glass electrode 1 5111014 Aluminium indirect 1 5110095 Indirect spiral glass electrode 1 5111002 SDI QV DOLLS noqa n g n sede W ke yey ae II 2 5111015 Silicone tube
16. ater content Concentrated through the treated area the energy of the high frequency current is absorbed by the water molecules stimulating and making them vibrate and heat up High frequency increases the temperature and heats the tissues 25 START UP MANUAL ACB 4000 An unusual but very useful effect of high frequency current is that it passes along a conductor like a wire or metallic bar to its end Then its energy passes cleanly until the end of the conductor to be transmitted as radio waves Any radio television or radar transmitter depends on this effect The frequencies used in the beauty treatment appliance must not cause undue interferences in radio and television receivers Located near another conductor such as a piece of metal or the body but not touching high frequency will skip the space between the two elements with a sparkle It is this sparkle which produces the stimulation and asepsia effects during the beauty treatment These sparkles can create slight electrical shocks if not enough attention is paid High frequency in the beauty treatment Two types of high frequency are used for their aesthetic effects One is a high frequency current of lesser frequency and high voltage this is not really a contradiction This current is produced by the high frequency appliances of beauty salons and by the beauty treatment appliances The frequency is around 100 000 to 250 000 hertz and if it is transmitted from the elec
17. aving a certain amount of energy on the skin in the form of heat This rise of temperature although not very high is capable of acting on the biological reactions by increasing them as well as the cellular oxygenation and eliminating carbon dioxide Peripheral vasodilator effect A pronounced effect of these currents is the stimulation of the peripheral blood flow The peripheral action of the high frequency produces a slight reddening of the skin Antibacterial effect Another important clearly demonstrated effect of high frequency is the antibacterial action of these currents as well as that of weakening the activity of the bacterial toxins This is mainly due to the formation of ozone The spark or arc light that passes from the electrode to the skin crosses the small layer of air that separates them producing the physical phenomenon of converting atmospheric oxygen into ozone This gas is very unstable and reacts rapidly with different compounds causing an oxidation that explains its germicide and antiseptic properties EMA 24 START UP MANUAL ACB 4000 High frequency accessories The accessories of a high frequency apparatus are glass or quartz electrodes with diverse shapes and applications When the current goes through the electrodes it lights up inside with an orange light if it is made of NEON or blue if it is of VIOLET As the multiple qualities of high frequency currents are known we are not going to show here more t
18. by arterial spiders The extractor does not effect the muscular system and therefore cannot make wrinkles disappear However it is convenient to treat them with the compressor to clear the impurities and the keratinous layer that forms on them The proper treatment with the extractor is carried out making perpendicular vertical movements at the surface of the skin The suction cup must be removed on one point without dragging the skin The suction cups provided with the equipment include a hole that allows the beauty professional to control the level of suction by blocking or unblocking the glass hole After a firsts aspiration raise the suction cap and apply it on another point Never move the suction cup horizontally The power applied to the extractor must not be excessive in order to avoid injuries of the skin as a consequence of the accumulation of peripheral blood flow attracted by the suction A mild power is enough to dilate the pores and remove the impurities fat blackheads etc 37 START UP MANUAL ACB 4000 START UP U N e Check that the equipment is connected Activate the on switch 2 Join the silicone tubes supplied with the equipment with the tube corresponding to the extractor 11 If the process turns out to be difficult blow inside the rubber tube the operation should then work Apply the suction cups on the skin Choose the power desired according to the tissue to treat and client s
19. ctro cosm tique ACB 4000 EMA CLASS I TYPE BF UNE EN 60601 EN 61000 3 2 EN 61000 3 3 EN 50081 1 EN 55011 EN 5002 1 EN 61000 4 2 EN 61000 4 2 EN 61000 4 3 ENV 50204 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Signed Pilar S nchez L 44 START UP MANUAL ACB 4000 MANUFACTURER S NOTE Our wish to offer to the aesthetic sector equipments that keep adapting to the requirements of this young profession leads us to conceive new equipments and to try and improve those already existing For this reason we are compelled to reserve the right to modify these specifications without prior notice All equipments are intended for a mains voltage of 230 V If you require it for a voltage of 125 V please inform your supplier at the time of order The inappropriate use not included in this instruction manual from the beauty professional can have undesirable results The manufacturer is not responsible for the results derived from an improper use of the machine EMA 45 START UP MANUAL ACB 4000 SUGGESTIONS Your opinion is important to us You can send your comments and suggestions to get a better service day after day You can write at the following address EMA BIOINSIDE INVESTIGACION Y TECNOLOGIA S L REGISTRATION No B60829793 MAIN OFFICES AND MANUFACTURING Sant Marti de l Erm 22 Poligono Industrial Fontsanta 08970 Sant Joan D
20. er or sunbathing since it facilitates a faster and more homogenous tanning thanks to an easier penetration of ultraviolet radiation As for the face body brushing must be done with care especially in sensitive areas like the underarms the bikini line the popliteal fossa the inner arms and thighs etc Brushing can also be performed on creams oil biological or nutritive products etc for an easier application Bristle brushes and the rotational movement provide a smooth and regular micromassage that together with the reddening produced enables the topical products applied to penetrate in depth The machine includes various sized brushes allowing to adapt to the requirements of the area to be treated EMA 20 START MANUAL 4000 START UP Check that the equipment is connected Activate the on switch 2 Insert the plug into the brushing outlet 4 on the front of the machine Hold the brush holder handle leaving it from it Support and place the chosen brush in it by pressing lightly Turn the potentiometer 3 to the right to choose the rotation speed wanted Apply the brushing onto the treatment area Remember that the size and intensity of the module must be adapted to the sensitivity and extension of the area to be treated The rotation direction of the brush can be modified by pressing the switch 5 At the end of the treatment clean the brushes and place the brush ho
21. esp Barcelona Spain Tel 34 93 477 42 62 Fax 34 93 477 42 90 info ema es BARCELONA DELEGATION C Gerona 156 Bajos 08037 Barcelona Spain Tel 34 93 459 18 54 Fax 34 93 459 11 32 barcelona ema es National number 902 31 51 71 International number 34 93 477 42 63 EMA 46 START MANUAL NOTES AND COMMENTS EMA ACB 4000 47 START MANUAL 4000 EMA BIOINSIDE INVESTIGACION TECNOLOGIA S L Sant Marti de l Erm 22 Poligono Industrial Fontsanta 08970 Sant Joan Despi Barcelona Spain Tel 34 93 477 42 62 Fax 34 93 477 42 90 info ema es EMA 8
22. han a few of the many treatments that can be performed and that are the most common HIGH FREQUENCY High frequency is a beauty treatment that both beauticians and clients either love or hate because without reasonable care it is easy to give yourself or the client small benign but appreciable electrical shocks So why do we use it Depending on how it is used it can be peripheral circulatory and soothing stimulating astringent or mildly antiseptic A high frequency current is basically a very fast alternating current An alternating current alternating few times every second is a ow frequency current for example the socket that alternates with a frequency of 50 hertz An alternating current alternating at thousands of hertz is medium frequency Currents of 4000 hertz used in interferential beauty treatments are an example An alternating current alternating at 100 000 hertz or more even millions of hertz is high frequency At these frequencies these currents have some unusual properties that are used in beauty treatments Properties of high frequency High frequency goes through the body in a very simple manner Remember that high frequency means ow impedance This also means that it easily goes through all types of substances that are normally electrical insulants and at high voltages the current is very difficult to contain This explains the ease with which those small electrical shocks take place Body tissues have a high w
23. keratin and without a nucleus This layer is responsible for the relative impermeability of the skin which makes body water evaporation and substance or cosmetic product penetration difficult Reddening effect Peripheral blood flow is stimulated through the brushing of the skin which provokes a slight reddening of the skin This effect is very beneficial since it improves the nutrition and oxygenation of cutaneous cells With its beneficial effects on the skin the brushing is important in order to remove the excess of dead cells before starting any treatment This way the extraction of impurities and of sebaceous accumulations of the 19 START UP MANUAL ACB 4000 blackheads becomes easier Brushing must be carried out before applying ozone vapour once the skin is free from make up and impurities It can be done with dry or humid brushes but the most frequent form of application is with a peeling cream When the epidermis is free from dead cells it is considered ready to receive the appropriate products Its use before any electro aesthetic treatment is very efficient since it decreases the resistance of the skin and thus activates the effects of the subsequent treatment This technique can also be applied to the whole body whether as a preparation to a specific treatment or as a treatment itself Brushing is an action which immediate result is a smooth oxygenated skin It is particularly indicated before the summ
24. lder handle in its corresponding support Turn off the main switch 2 EMA 21 START UP MANUAL ACB 4000 IMPORTANT e The movement of the brushing on the skin must be mild and homogenous A violent brushing could upset the skin which would lose a part of its natural protection e Be extremely cautious on areas where the skin is the most sensitive eye orbiculars underarms popliteal fossa the inner arms and thighs etc e Attach great importance to the cleansing and disinfection of the brushes after each use e Brushing is not recommended in the following cases pustules rosacea telangiectasia eczema furunculosis adenitis varices and lesions EMA 22 START UP MANUAL ACB 4000 2 HIGH FREQUENCY at a The high frequency unit corresponds to the second gt window of 4000 The photo shows the corresponding to this application 2 23 START MANUAL 4000 HIGH FREQUENCY MODULE High frequency is a variable alternating current with an approximate voltage of 30 000 to 40 000 volts and a frequency of 150 to 200 kilocycles As it is found at very high frequencies this current is not capable of producing muscular excitation since to obtain a muscular contraction the wave needs to last besides having a certain intensity Thermal effect The thermal effect is produced by the passage of an electric arc from the electrode to the person treated le
25. le This electrode can give unpleasant sparks in the hands if not firmly held by the client A cylindrical glass electrode is much more comfortable to use An intensifier with a metal spiral inside can also be used Cx metal tube saturator N a A 8 Direct application of high frequency m glass vacuum tube snr i Saturator T gt gt T d A ca f 0 FE V 0 ea lass vacu f ha irate 4855 vacuum iubDe lt with intensifier High frequency treatment can be used in the client in two different ways method of direct application and of indirect application EMA 28 START UP MANUAL ACB 4000 In the direct method the beauty professional fixes the electrode in contact with the treatment area and moves it gently over the surface of the skin The electrode discharges its high frequency energy in the skin on the point of contact Besides this heating effect the stimulating effects of sparking take place between the electrode and the skin The superior and predominant effect of direct high frequency is that of an increase of stimulating temperature In the indirect method the client holds the saturating electrode To prevent the wear and suffering of the electrode the client must hold the electrode holder handle with one hand and the electrode with the other He she is therefore charged with high frequency energy The beauty
26. m in the form of radiowaves Alternatively there can be a cable of extremely flexible cord that can also be applied to the treatment area Electrodes used aesthetics A variety of glass electrodes are used for the beauty treatment with high frequency For the majority of the treatments a metal electrode could dangerously shower the clients with sparks Glass electrodes are objects of closed surface that have been given specific Shapes to cover each treatment There is void inside them High frequency is introduced through the metallic terminal that must be inserted by pressure in the electrode holder handle ae electrode holder y cO giass envelope iae st ee N Saza k Ep Es near vacuum OE a skin electrode Mr EN small for the face CN P p large for the body Cr er iis E nr U Y i TUN N rake electrode metal cap CM for scalp treatment 1 _ square end electrode for sparkle engages socket in holder treatment of skin to prevent electrode turning impurities High frequency energy causes ionisation of some of the atoms of the little quantity of air inside the electrode In ionization some electrons are expelled from the atoms converting them into charged jons The current then flows easily across the tube until the contact point with the skin making these ions vibrate The ions however soon recover their electrons and return energy by
27. olts in European countries e The socket where the equipment is connected must be in perfect conditions 4 2 This guarantee becomes invalid if A The equipment is used improperly B The electrical installation or the regulator connected to the equipment are defective C The equipment is exposed to overloads short circuits electrical discharges floods or other similar unforeseeable circumstances D The equipment is handled or repaired by staff non authorised by EMA EMA 43 START MANUAL DECLARACION DE CONFORMIDAD DECLARATION OF CONFORMITY DECLARATION DE CONFORMIT 89 336 73 23 CEE MARZO 2003 MARCH 2003 MARS 2003 ACB 4000 Electroest tica amp Mobiliario Nombre del Fabricante BIOINSIDE INVESTIGACI N Y TECNOLOG A S L Manufacturer s name Nom du fabricant Direcci n del Fabricante Manufacturer s address Adresse du fabricant Declara que el producto Declares that the product D clare que le produit Nombre del producto Name of the product Nom du produit Marca Brand Marque Cumple con la normativa Complies with the norm Est conforme la norme Seguridad El ctrica Electrical Security S curit lectrique Compatibilidad Electromagn tica Electromagnetic Compatibility Compatibilit lectromagn tique Sant de Erm 22 E 08970 Sant Joan Desp BARCELONA SPAIN Electrocosm tico Electrocosmetic Ele
28. owly slide the electrode on the client s cutis always with an up and down movement In both start with a low intensity Another type of treatment is that which is performed with the pencil shaped glass electrode This electrode is used to carry out fulgurations 3 Beauty treatment of dandruff and hair loss High frequency has an important microbicidal action due to the ozone that it produces But besides it generates a vitalizing action on the cells of the dermis and epidermis thanks to its great power of penetration and improvement of the blood flow These two actions are combined to revitalize the scalp For the treatment of dandruff and hair loss the comb shaped glass electrode is used The intensity must be somewhat higher than in other treatments but the application time must not last more than three minutes EMA 32 START UP MANUAL ACB 4000 4 Other applications of high frequency High frequency can also be used to fight blackheads It is also advisable to apply this shower of sparks after a depilation since it helps to reduce the irritation produced on disinfecting the epidermis thanks to the action of the ozone EMA 33 START MANUAL 4000 START UP U N e Check that the equipment is connected Activate the on switch 2 Insert the extremity into a plug in the high frequency outlet 7 on the front of the machine Hold the electrode holder handle in your hand taking it out of its
29. pparatus proper operation by purifying the inconstant electrical signal received by the user and creating a continuous stable signal Sensitive equipments can then work properly since they receive the same amount of mains voltage at all time 42 START UP MANUAL ACB 4000 GUARANTEE AND SAFETY 1 The manufacturer is not responsible for an improper use of this machine nor for the consequences derived from it Any use not included in this instruction manual can be dangerous We therefore ask you to consult your nearest authorised distribution centre for any doubt 2 Our wish to include possible improvements in our appliances compel us to reserve the right to modify the characteristics of our equipments without prior notice 3 All equipments are provided for a mains voltage of 230 volts If you require a voltage of 125V notify it to your provider at the time of the order 4 AS MANUFACTURERS we offer a 24 month guarantee on our equipments against any manufacturing fault In order for this guarantee to be efficient the following technical specifications must be taken into account 4 1 Minimum specifications in the electrical installation e The equipment must always be connected to the electrical current by means of a voltage regulator with ground point whose output voltage must be included between 110 and 120 volts in the case of installations with this voltage particularly in Latin American countries or 220 and 230 v
30. professional then gently massages the client and high frequency is discharged from the client towards the fingers of the beautician in contact concentrating the energy the heat in that area There is little sparking and therefore little stimulation Summarizing The application of direct high frequency produces an rise of temperature and is stimulating The application of indirect high frequency produces a rise of temperature and is soothing Effects of high frequency The reactions of the body to high frequency treatments are responsible for the heating and when there is a direct application for the responses to sparking In a way both types of response are in conflict Effects of heating The rise in temperature diminishes the responses of the periphereal nervous system This way a soothing effect is produced The heating produces the dilatation of the blood vessels increasing the flow of fluids through the area to disperse the heat This will increase the biological reactions and the recovery time of the damaged tissues In the areas of the body with greater fat accumulation such as the breasts it can stimulate the accumulation of fat However those using this treatment as a system to add centimetres in this area are soon disappointed with the results or the absence of them The heating produces however an increase of sweating and of the sebaceous secretion that contributes to the deep cleansing of the skin in the are
31. s must be removed When the treatment begins do not connect the machine until the electrode enters in contact with the skin or place your finger over the glass until it comes into contact with the skin which can also reduce the initial electrical shock Likewise at the end of the treatment disconnect the appliance or put the finger on the glass again before lifting the electrode This is done to avoid sparks between the void of the electrode and the skin COMPACT 500 includes electrode holders with a button in the handle to produce current only produced when that switch is activated Do not use high frequency on skin recently sprayed with lotions of alcohol or sulphur base lest it would produce fire in the client s skin Beauty professionals normally complain that they receive many electrical shocks from their high frequency equipments and ask themselves what mistake they have made The answer is as simple as thinking that the glass electrode has been contaminated with the skin cream or by talcum powder and that the current is dragged with these remainings throughout the machine You can appreciate how a film of moiturising cream can conduct high frequency but it is hard to believe that the talcum powder does it too The solution is to clean the machine and the electrode holder handle with a cloth moistened with alcohol without forgetting to clean the connector in which the electrodes are introduced 31 START UP MANUAL ACB 4000
32. support and introduce in it the the electrode that we are going to use until it is well held Observe that there is an on switch on the high frequency handle Turn the potentiometer 6 to the right and select the appropriate intensity according to the type of treatment and the client s sensitivity Activate the electrode holder handle Be sure to press the on switch of the same electrode holder handle to give the order of movement to the current This switch is very useful to stop the treatment once the session is finished independently from the machine The electrode will light up and the high frequency appliance will be activated When using the metallic electrode it EMA 34 START UP MANUAL ACB 4000 is VERY IMPORTANT that the beautician asks the client to hold it in their hand BEFORE turning the high frequency module on 7 At the end of the treatment lower the power and disconnect the module through the regulation potentiometre 6 turning it to the left If we have used the metallic electrode it is now and NOT BEFORE that the client must release it 8 Remove the electrode from the handle and place it in its corresponding place with the electrode holder handle 9 Turn off the on switch 2 IMPORTANT The following points must be observed for any treatment e Hold the electrode holder handle the furthest possible from the current transmitting orifice e The application time of high frequency recomendable per
33. t area is uniformly soaked with the microdiffused liquid withdraw your finger from the regulating orifice 9 At the end of the session put the potentiometer 9 to zero 10 Turn off the main switch 2 11 To end the treatment dry the skin with a paper tissue IMPORTANT It is recommended that one of the bottles contain a normalising tonic and the other one soothing tonic were the first to produce unexpectedly a type of allergic reaction in the client It has been observed that the metallic parts of the spray microdiffusor can be damaged when using certain tonics The beauty professional Should assess the type of products he wishes to spray and the aggressivity of their chemical principles in relation with the ACB 4000 containers It is advisable to choose tonics that will not induce the progressive deterioration of materials Remember that a good hygiene is important as much for the spraying bottles as for the silicone tubes in order to extend the lifetime of these accessories It is therefore recommended to clean these containers regularly with soap and water EMA 41 START UP MANUAL ACB 4000 POSSIBLE TECHNICAL PROBLEMS 1 The machine ts not working Why The cable of the accessories may be cut in one of its points or at the extremity of connexion to the machine For a proper operation of the machine replace the broken part of the cable The equipment blocks any current output when it detects a leak To extend the life
34. time of these accessories it is recommended to place the apparatus at a 90 angle from the working couch to avoid any unnecessary suffering of the cables Also check that the plug is connected properly and that tension reaches the appliance you can check the presence of current with another equipment Verify the rear connector and the reliability of the mains cable using it to connect another appliance It thus indicates that the problem does not come form the mains cable Once these verifications are made the protection fuse may be examined to see if it has not meted Finally make sure that the mains voltage corresponds to that of the equipment If the pilot light is on but the machine is not working check with this start up manual that the operation process is the right one If the problem persists consult the technical department 90 OF TECHNICAL PROBLEMS COME FROM A LACK OF ATTENTION WHEN HANDLING THE BUTTONS AND FROM THE NATURAL WEAR OF THE ACCESSORIES For this reason please check all these details before contacting your nearest technical service 2 I discovered that the equipment does not work properly since yesterday However there has been a storm Storms and rains can sometimes affect national hydroelectric systems If you discover problems with your electrical equipments after a storm especially the most sensitive it is advised to connect a current stabiliser to the machine This electrical device facilitates the a
35. trodes is radiated as Jong wave radio waves The other one is a current of greater frequency lower voltage used for epilation the permanent elimination of unwanted hair Its frequency is usually 27 150 000 hertz or 27 12 megahertz When it is transmitted through the epilation needle it is radiated as short wave radio waves This system of epilation is called epilation by short wave High frequency current The outlet of the high frequency current is an alternating current of high frequency 100 000 to 250 000 hertz but of fairly low power so the flow of the current is very low Applying high frequency to the client High frequency appliances in aesthetics transmit high frequency energy to the client using a single electrode Fairly unusual for electrical currents it does not need two connections to complete a circuit The energy of high frequency is in contact with the ground or dispersed within the client s body The effects of the current are concentrated around the contact point of the electrode and for this 26 START UP MANUAL ACB 4000 reason can only be superficial The special electrodes necessary are those described below Physiotherapists require much more often a heating effect much deeper from their diathermia appliances by high frequency They normally have two electrodes located in both arms both sides of the area to treat and high frequency is introduced through the human tissues situated between the

Download Pdf Manuals

image

Related Search

Related Contents

Sandberg StreetBlaster  Toshiba 32HL833  Da-Lite Heavy Duty Deluxe  1. warnings caution before first use general note  AGRAL® 90 - Agrytec.com  Manuel d`utilisation  Alarmas por sobrellenado del tanque TS-RA1, TS-RA2 y TS-RK  Manual de Usuario para Inscripción de Empresas  Service Bulletin - Terry`s Jaguar Parts  Quick Start User Guide  